iIDPENsolid HF User Manual RFID Read/Write Device for mobile scan applications iID PENsolid is a mobile RFID device suitable as Bluetooth enabled RFID read/write unit for HF
(13.56MHz) frequency applications. Based on its PEN style form and the implemented touch tip it can be used as input device for tablets and smartphones with touch and capacitive screens. iID PENsolid can be configured in Bluetooth HID mode. In this operation mode it emulates a Bluetooth keyboard. Depending on operation mode, iID PENsolid works together with Windows, Android and iOS devices. Product Short Description & available Versions:
iID PENsolid System: iID-3000 RFID Pen Style Read/Write HF Unit v1.00 with RTC, MEM, BT, USB, Li accu Display: LEDs for power, BT, status Buttons: SCAN, ON/OFF System: iID3000, ISO 15693, 14443, all customized Antenna: K3 Operation Mode: DOC / SPC Bluetooth: SPP / HID Case Format: 120x26x20 mm, Li Ion Battery 450mAh Product Code: 73.72.750.xx An additional product version of iID PENsolid is available for UHF (868 / 915 MHz) RFID applications. Please contact microsensys for further information. UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual FCC compliance statement These devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. These devices may not cause harmful interferences;
2. These devices must accept any interference received, including interference that may cause undesired operation. The following figures list the Grant by FCC ID Number for each of the following devices:
FCC ID:
ZLCPENSOLIDHFX Please refer to the FCCs website ( http://www.fcc.gov/ ) to view the grant and related documentation. CAUTION !
Exposure to Radio Frequency Radiation. The radiated output of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches) during normal operation. These devices may not be co-located with any other transmitter or transmitter antenna. NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interferences when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Microsensys GmbH could void the users authority to operate the equipment described in the manual. This device contains Bluetooth module FCC ID:
QOQWT12. IC compliance statement Industry Canada ID: 21228-PENSOLIDHFX, contains Bluetooth module IC ID: 5123A-BGTWT12A This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio RSS-210. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Performance description iID PENsolid is suitable for mobile data capture and wireless RFID read / write applications, which can be connected via its integrated USB interface to PCs. The BluetoothTM-Interface is suitable to connect to smart phones, tablet computers or laptops. Based on iID SPC functionality, scripts can be used for definition of LED, buzzer and button support as well as communication functionalities as RF, USB and Bluetooth. iID PENsolid is a battery powered device, which can be recharged using the micro USB interface. Battery cycles may vary from some hours to several days depending on the device configuration. When the device is connected via its USB interface, the device is powered by USB power. The device is available in several types supporting HF as well as UHF systems suitable for closed coupling communication with very small sized up to large RFID transponders. Additionally all devices support TELID sensor transponder applications. First commissioning
(1) ON/OFF button Hole for hand strap, clip Micro-USB connector
(3) rechargeable battery state LED (orange)
(4) Bluetooth state LED (blue) Focused RFID antenna, main RF field direction
(2) SCAN-
button Before using your device the first time, please charge the internal rechargeable battery using included micro USB cable.
(5)(6) Green and operation state LED Touch tip red UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Manner of functioning iID PENsolid may be used as RFID read/write device with USB- or Bluetooth interface or RFID scanner using the integrated scan button. See following table for available configurations, for further information see iID SPC/MPC related documents. Functionality Operation mode Interface Remark Read/write interface DOC USB configuration Bi-directional USB communication, based on iID driver engine, device configuration Bluetooth HID (human interface device / key-
board mode) SPC Bluetooth HID Uni-directional communication, script with output functionality on device iID PENsolid is delivered in SPC/HID mode. Please adjust operation mode connecting to a PC via USB interface. Using iID interface configuration tool you may configure the device according your requirements before first usage. Microsensys provides sample scripts for device usage in SPC mode, which are available for download in iID interface configuration tool. iID PENsolid buttons support following functionalities:
Button
(1) ON/OFF
(2) SCAN button
(1) and (2) Functionality Power on device, power off device when pressed for 3 seconds Perform scan (while device in SPC mode) Keep holding (1) and (2) while device is off until lights come up will switch on device and perform Bluetooth reset. UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Software to be installed Please download and install iID software package including iID DEMOsoft 2013, iID interface config tool and iID connection tool as well as iID driver engine from:
http://download.microsensys.de/CDContent/Install/Setup%20iID%c2%ae%20software%20package.exe. Device configuration is possible using iID interface configuration tool running on Windows PC environment
- via BT connection as well as USB interface. For using USB interface you may also need to install the USB driver, which is available at http://download.microsensys.de/CDContent/USBDriver/Microsensys%20USB%20devices%20driver%20CD M%20v2.10.00%20WHQL%20Certified.zip Depending on operation mode (see manner of functioning) and platform installation of further software may be required:
Operation mode Platform Software DOC Windows
(without RT) 32/64 iID software package including iID driver engine, optional iID tray application
(http://download.microsensys.de/CDContent/Install/iID%c2%ae%20tray%20ap plication.zip) Windows Mobile, Windows embedded handheld Android SPC
(Bluetooth HID) All platforms
(Windows, Android, iOS) iID driver engine, iID DEMOsoft
(http://download.microsensys.de/CDContent/Install/RFIDDriver/Windows/iID30 00PRO/, http://download.microsensys.de/CDContent/Install/iID%c2%ae%20DEMOsoft/
Windows/Mobile/RFID-Demo%20iID%20driver%20engine.CAB)
, optional iID trigger scan
(http://download.microsensys.de/CDContent/Install/iID%c2%ae%20tray%20ap plication/iID%c2%ae%20TriggerScan%20Mobile/iID%20TriggerScan.CAB) iID Android DEMOsoft
(http://download.microsensys.de/CDContent/Install/iID%c2%ae%20DEMOsoft/
Android/) No further software required Further microsensys product related software is located here: http://download.microsensys.de/CDContent/. UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Signs & their meaning iID PENsolid LEDs are used to show operation state. Additionally there are device states shown as described below. Symbol Description
(3=ORANGE)
(4=BLUE)
(5) operation state LED
(GREEN)
(6) operation state LED
(RED)
(5) & (6) OFF = battery good, BLINK = low charge, ON = USB charging BLINK = Bluetooth connection not established, ON = Bluetooth connection established In DOC mode automatic RF state visualization, programmable In DOC mode automatic RF state visualization, programmable Blinking while POWER_ON or POWER_OFF in SPC mode in SPC mode free free Safety instructions The device may only be used for the intended purpose designed by for the manufacturer. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes. When working on devices the valid safety regulations must be observed. UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Technical data Following table contains general technical data. Parameter Housing Material Dimension Power supply Description Plastic case 117mm x 27mm x 19(23)mm 2 buttons USB (power supply) micro USB female, 5V +/- 5%, ripple <50mV Battery Current consumption Sleep mode Idle mode Active mode RFID Interface Carrier frequency Lithium polymer battery, 3.7V, 420mAh typ. 5A typ. 30mA typ. 200mA 13.56MHz +/- 7kHz Implemented standards ISO14443, ISO15693 RF output power Antenna Operating distance Additional interfaces Bluetooth interface USB interface Operation modes DOC SPC 200 mW K3 0mm .. 50mm (depending on transponder type and environmental conditions) Bluetooth 2.0 USB 2.0 Direct online communication, serial communication or iID driver engine or iID Android driver engine Script programmed communication, HID communication or serial communication or iID driver engine or iID Android driver engine UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide iIDPENsolid HF User Manual Equipment delivered:
Standard accessories:
1 x iIDPENsolid Including following Accessories:
1 x Hand strap 1 x USB cable 1 x CD-ROM (Software & Documents) USB cable Hand strap Complementary microsensys Documents Technical Datasheets:
PENsolid-HF xxx.pdf, PENsolid-UHF xxx.pdf Product or System Documentation:
DOC-iID SPC 01D.pdf, Quick-iID MPC 01D.pdf Contact/Copyright Micro-Sensys GmbH In der Hochstedter Ecke 2 99098 Erfurt Germany phone: +49 (0) 3 61 5 98 74-0 fax:
+49 (0) 3 61 5 98 74-17 e-mail: info@microsensys.de web: www.microsensys.de Any reproduction of this short manual in whole or in part, the storage in electronic media and the translation into foreign languages without the written permission of microsensys GmbH is forbidden. 2016 microsensys all rights reserved UserMan-iID PENsolid HF-007E.docx 2016 microsensys QuickStartGuide