U-Class Z-wave IoT Gateway (ZWG81000B) User Manual USER MANUAL U-Class Z-wave IoT Gateway ZWG81000B U-Class Z-wave IoT Gateway (ZWG81000B) User Manual CONTENTS CONTENTS ......................................................................................................................................... 2 1. Description ................................................................................................................................ 3 2. Product Overview ...................................................................................................................... 4 Full ..................................................................................................................................... 4 2.1. Front view ......................................................................................................................... 4 2.2. 2.3. Side view ........................................................................................................................... 5 Back view........................................................................................................................... 5 2.4. Specifications ............................................................................................................................ 6 3. 4. Indications ................................................................................................................................. 6 Installation ................................................................................................................................ 7 5. Instructions ............................................................................................................................... 8 6. 6.1. POWER ON/OFF ................................................................................................................ 8 Web Console ..................................................................................................................... 8 6.2. System Status .......................................................................................................................... 9 6.3. Gateway Information ........................................................................................................ 9 6.3.1. 6.3.2. Network Information ........................................................................................................ 9 Gateway Management .................................................................................................... 10 6.4. Network Configuration.................................................................................................... 10 6.4.1. 6.4.2. Server Configuration ....................................................................................................... 11 6.4.3. Time Configuration ......................................................................................................... 12 6.4.4. Modify Password .................................................................................................................. 13 6.4.5. Upgrade ................................................................................................................................. 13 Reboot ............................................................................................................................. 14 6.4.6. Device Management ....................................................................................................... 16 6.5. 6.5.1. Inclusion .......................................................................................................................... 16 Exclusion .......................................................................................................................... 17 6.5.2. Remove malfunction device ............................................................................................ 18 6.5.3. 6.5.4. Replace malfunction device ............................................................................................ 18 Association and configuration ......................................................................................... 19 6.5.5. Advance ........................................................................................................................... 20 6.6. SSL ................................................................................................................................... 20 6.6.1. 6.6.2. Backup ............................................................................................................................. 21 Restore .................................................................................................................................. 22 6.6.3. Default ............................................................................................................................. 23 6.6.4. 6.6.5. Z-Wave......................................................................................................................................... 24 System Log ....................................................................................................................... 26 6.7. Reset gateway IP .............................................................................................................. 26 6.8. 6.9. Reset Password ..................................................................................................................... 26 2 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 1. Description Congratulations and thank you for using Mainbo U-Class Z-wave IoT Gateway device. U-Class Z-wave IoT gateway takes central place in IoT automation system. Combined with U-
Class client (Android/iOS/HTML) applications and U-Class cloud services. It provides a turnkey platform that covers lighting, security, safety, energy management and other aspects of the fast-
growing IoT automation markets. By supporting the most popular wireless communication protocols today, U-Class Z-wave IoT gateway communicates with connected devices and enables users to monitor and control their equipment through Z-wave plus technologies. Below you will find useful operating guidelines. WARNING!
The 5V port of this unit is to be connected only to the devices whose power feeding meets the requirements for SELV (Safety Extra Low Voltage) and complies with Limited Power Source according to IEC 60950-1. 3 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 2. Product Overview 2.1. Full Back Side Front 2.2. Front view Item 1 2 3 4 5 6 Name POWER Description Power supply status indicator DOWNLOAD Download status indicator ADD/DEL Z-Wave WAN LAN Inclusion and exclusion indicator Z-Wave communication indicator Wide area network indicator Local area network indicator 4 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 2.3. Side view 7 Item Name Description 7 ADD/DEL key Push-bottom for inclusion or exclusion Z-wave devices 2.4. Back view Item Name Description 8 9 10 11 12 13 DC/5V RST HOST SLAVE LAN ANT Power plug Reset to default IP and password USB host USB slave Ethernet RJ-45 socket Z-wave RF communication antenna 5 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 3. Specifications Table. 3-1 Item CPU DRAM Flash Power Voltage ARM9 (400 MHz@1.0V +/- 10%) with ZM5202 Specification 128M 256M 5DCV Power Current 0.5A Consumption
<2.5w Frequency RF Range Nodes Protocols 908.42MHz 30 meters (in-door)100 meters (out-door) 232 TCP/IPUPNPDDNSHTTPDNSZ-Wave Temperature 10-45 Humidity 10%-70%RH Power Supply External DC power adapter (5VDC@2A) Weight 200g Dimension 224mm*170mm*42.5mm 4. Indications Indication POWER, Blue ON RJ-45 Socket, Amber ON RJ-45 Socket, Green ON RJ-45 Socket, Green Blink DOWNLOAD, Blue ON ADD/DEL, Green Blink ADD/DEL, Blue Blink Status Device power on LAN connected with 100M LAN connected Data transferring Gateway is upgrading Z-wave exclusion mode Z-wave inclusion mode ADD/DEL, Green and Blue cross Blink Z-wave routing table re-build ADD/DEL, Blue ON then OFF IP reset (press and hold RST key for 3 seconds) ADD/DEL, Green ON then OFF Password reset (press and hold RST key for 10 seconds) Indicators ON sequential Gateway is booting Z-wave, Blink Z-wave is communicating 6 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual WAN connected Confirming internet connection No internet connection LAN connected Data transferring No intranet connection WAN, Blue ON WAN, Blue Blink WAN, OFF LAN, Blue ON LAN, Blue Blink LAN, OFF 5. Installation Before using Mainbo U-Class Z-wave IoT Gateway, please read the following information to avoid any potential dangers:
Read the instructions carefully and follow the precautions in this manual. All mains connections must be carried out by a trained and qualified person Only use the original mains adaptor supplied with the device Disconnect the device from mains (mains chargers) before cleaning. Clean device with a damp cloth, do not use detergents Do not use device in gas-filled environments Do not place the device near heat sources Do not expose the device to direct sunlight Do not place cables and/or power supplies under heavy objects. Also, avoid routes near sharp or abrasive objects and walkways Keep out of reach of children Do not carry out any maintenance on the device, instead contact your supplier Make sure that ventilation slots and the cooling unit are not covered As the device generates heat, this can lead to discoloration on the surface of furniture. Make sure there is at least 10cm of clearance around the device The device must not be located in the space with a high level of humidity e.g. kitchen, bathrooms, etc. Under no circumstances should you open the device or the mains adaptor. This must only be carried out by a qualified engineer Do not touch any contacts on the device with your fingers or metal objects. This could cause a short circuit Do not handle the device when your hands are wet due to risk of electric shock 7 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6. Instructions 6.1. POWER ON/OFF Power ON PurposePower ON gateway, boot up system. Steps Step-1Plug-in power adapter and Ethernet cable. Power OFF PurposePower OFF gateway, shut down system. 6.2. Web Console PurposeGateway Configuration Steps Step-1Open a IE or Chrome browser on a PC which connected to the same LAN network with gateway. Step-2Type-in the IP address, ex:192.168.0.100. Default IP192.168.0.100 Step-4Type-in the password. Default Password888888 Step-5ClickLogin 8 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.3. System Status 6.3.1. Gateway Information PurposeCheck information about gateway, including gateway ID and firmware version. Steps Step-1Click System Status/Gateway Information on the left of Web Console 6.3.2. Network Information PurposeCheck information about network, including IP, submask and gateway IP. Steps 9 Step-1Click System Status/Network Information on the left of Web Console U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.4. Gateway Management 6.4.1. Network Configuration PurposeGateway network and name configurations Steps Step-1Click Gateway Management/Network Configuration on the left of Web Console Step-2Modify settings according to the LAN environment. Step-3Click Apply Step-4Click Reboot 10 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual
(New parameters will be taken after gateway reboot) 6.4.2. Server Configuration PurposeServer Configuration Step Step-1Click Gateway Management/Server Configuration on the left of Web Console Step-2Type-in IP address or domain name of Server Step-3ClickSubmit Step-4Click Reboot
(New parameters will be taken after gateway reboot) 11 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.4.3. Time Configuration PurposeSystem date and time calibration and configuration Step Step-1Click Gateway Management/Time Configuration on the left of Web Console Step-2Click Grab time at right, it will show current time settings. If time setting in-correct, user can modify it manually (Step-2A). User also can reset server to obtain updated time (Step-2B). Step-2AModify time and then click submit Notice:
User must input the text in order to the format as shown. Step-2B see 6.4.2 Server Configuration 12 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.4.4. Modify Password
* Strongly recommend to change password once system active. PurposeChange the password for administrator Steps Step-1Click Gateway Management/Password on the left of Web Console Step-2Key-in original password and new password, then click Submit
(New password effected immediately, no need to reboot gateway) 6.4.5. Upgrade PurposeOn-line upgrade firmware Steps Step-1Click Gateway Management/Upgrade on the left of Web Console 13 Step-2Click Upgrade or Downgrade U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Step-3Choose the version Step-4Click OK, then wait for updating 6.4.6. Reboot PurposeReboot gateway Steps Step-1Click Gateway Management/Reboot on the left of Web Console 14 Step-2Click Reboot Step-3Click OK in the dialog U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 15 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Notice:
* Web console cannot be accessed during rebooting. 6.5. Device Management 6.5.1. Inclusion PurposeNew Z-wave device inclusion Method 1 Steps Step-1Login Web Console on PC browser Step-2Click Device Management on the left of Web Console Step-3Click Inclusion
(ADD/DEL indicates blue and blink slowly until inclusion success or time-out) Step-4Trigger the new device which want to add-in
(Please refer to the manual of device to know how to trigger the inclusion. ADD/DEL indicator will off once receive the message from device) 16 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Method 2 Steps Step-1Press the +/- key twice (each once about 1 second)
(ADD/DEL indicates blue and blink slowly until inclusion success or time-out) Step-2Trigger the new device which want to add-in
(Please refer to the manual of device to know how to trigger the inclusion. ADD/DEL indicator will off once receive the message from device) Notice
* Please perform Exclusion before Inclusion to erase old settings inside the device.
* Device must near by the Gateway when doing Inclusion (less than 3 meters) 6.5.2. Exclusion PurposeRemove the existing Z-wave device in the gateway Method 1 Steps Step-1Login Web Console on PC browser Step-2Click Device Management on the left of Web Console Step-3Click Exclusion
(ADD/DEL indicates green and blink slowly until exclusion success or time-out) Step-4Trigger the new device which want to remove
(Please refer to the manual of device to know how to trigger the inclusion. ADD/DEL indicator will off once receive the message from device) Method 2 Steps Step-1Press and hold +/- key for 5 seconds, wait for indicator starts blink
(ADD/DEL indicates green and blink slowly until exclusion success or time-out) Step-2Trigger the new device which want to remove
(Please refer to the manual of device to know how to trigger the inclusion. ADD/DEL indicator will off once receive the message from device) Notice:
17
* Device must near by the Gateway when doing Inclusion (less than 3 meters) U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.5.3. Remove malfunction device PurposeRemove malfunction Z-wave device Steps Step-1Login Web Console on PC browser Step-2Click Device Management on the left of Web Console Step-3Choose the device which want to remove, then click Remove
(ADD/DEL indicates green and blink slowly until exclusion success or time-out) 6.5.4. Replace malfunction device PurposeReplace malfunction Z-wave device with new one Steps Step-1Login Web Console on PC browser Step-2Click Device Management on the left of Web Console Step-3Choose the device which want to replace, then click Replace
(ADD/DEL indicates blue and blink slowly until exclusion success or time-out) Step-4Trigger the new device which want to remove 18 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual
(Please refer to the manual of device to know how to trigger the inclusion. ADD/DEL indicator will off once receive the message from device) Notice
* Please perform Exclusion before Inclusion to erase old settings inside the device.
* Device must near by the Gateway when doing Inclusion (less than 3 meters) 6.5.5. Association and configuration PurposeAssociate devices Steps Step-1Login Web Console on PC browser Step-2Click Device Management on the left of Web Console Step-3Choose the device, it will show Association, Configuration and Activation Notice
* Not every device supports Association, Configuration and Activation. Step-4AClick Association then choose multiple devices which want to associated. Then click OK Step-4BClick Configuration then key-in the parameters. Then click OK 19 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Notice:
* Different device contains different vendor and product parameters. Please refer to the manual of device for details.
* The number and value of parameter are both Hexadecimal
* Perform Step-4B repeatedly if there are multiple parameters for the device. Step-4CClick Activation 6.6. Advance 6.6.1. SSL PurposeEnable/Disable Secure Sockets Layer function Steps Step-1Click Advance/SSL on the left of Web Console Step-2ClickSupport SSL checkbox, then click OK 20 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.6.2. Backup PurposeGateway data backup Steps Step-1Click Advance/Backup on the left of Web Console Step-2Click Backup 21 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Step-3Once backup success, click Save as to store the file into your PC. 6.6.3. Restore PurposeRestore gateway data Steps Step-1Click Advance/Restore on the left of Web Console Step-2Choose the file name of backup.tar in the dialog. Step-3Click Restore and OK 22 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Notice:
* Gateway will reboot automatically once data restore successful. 6.6.4. Default PurposeReset gateway to factory default settings Steps Step-1Click Advance/Default on the left of Web Console Step-2Type-in password then click OK
(Gateway will reboot automatically about 60 seconds) 23 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.6.5. Z-Wave Re-build Route PurposeRe-generate the routing table between devices Auto-Polling PurposeTime interval of auto-polling for general devices Meters Auto-Polling PurposeTime interval of auto-polling for meter devices Duty-Hour Polling PurposeTime interval of auto-polling for switch devices duty-hour Steps Step-1Click Advance/Z-wave on the left of Web Console Step-2AClick the OK side by the Re-build
(ADD/DEL indicates green and blue cross blink till procedure done.) Notice:
* This task period base on the number of device in the Z-wave network. DO NOT re-login or shut down gateway during processing.
* All Z-wave devices should be working well during processing 24 Step-2BKey-in the value between 0 to 28800 into Auto-Polling U-Class Z-wave IoT Gateway (ZWG81000B) User Manual Notice:
* Frequently polling would cost system performance, please DO NOT set the value under 300. Step-2CKey-in the value between 0 to 28800 into Meter Auto-Polling Step-2DKey-in the value between 0 to 28800 into Duty-Hour Polling 25 U-Class Z-wave IoT Gateway (ZWG81000B) User Manual 6.7. System Log For maintenance only. 6.8. Reset gateway IP PurposeReset gateway IP to default setting Steps Step-1Press and hold Reset key for 3 seconds Notice:
* Default IP192.168.0.100 Submask255.255.255.0 Gateway IP192.168.0.1
* Please confirm settings of network after reset gateway IP 6.9. Reset Password PurposeReset gateway password to default setting Steps Step-1Press and hold Reset key for 10 seconds 26