all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 874.38 KiB | May 28 2021 / November 24 2021 | delayed release | ||
1 |
|
Internal Photos | Internal Photos | 1.09 MiB | May 28 2021 / November 24 2021 | delayed release | ||
1 |
|
External Photos | External Photos | 1.16 MiB | May 28 2021 / November 24 2021 | delayed release | ||
1 |
|
Label Information | ID Label/Location Info | 314.32 KiB | May 28 2021 | |||
1 |
|
Agent Authorization Letter | Cover Letter(s) | 465.59 KiB | May 28 2021 | |||
1 |
|
Applicant Declaration Letter | Cover Letter(s) | 529.29 KiB | May 28 2021 | |||
1 | BOM | Parts List/Tune Up Info | May 28 2021 | confidential | ||||
1 | BOM 1 | Parts List/Tune Up Info | May 28 2021 | confidential | ||||
1 | BOM 2 | Parts List/Tune Up Info | May 28 2021 | confidential | ||||
1 | BOM 3 | Parts List/Tune Up Info | May 28 2021 | confidential | ||||
1 | Block Diagram | Block Diagram | May 28 2021 | confidential | ||||
1 |
|
Confidentiality Request | Cover Letter(s) | 236.75 KiB | May 28 2021 | |||
1 | Operational Description | Operational Description | May 28 2021 | confidential | ||||
1 |
|
RF Exposure Report | RF Exposure Info | 1.83 MiB | May 28 2021 | |||
1 | Schematics 1 | Schematics | May 28 2021 | confidential | ||||
1 | Schematics 2 | Schematics | May 28 2021 | confidential | ||||
1 | Schematics 3 | Schematics | May 28 2021 | confidential | ||||
1 | Schematics 4 | Schematics | May 28 2021 | confidential | ||||
1 |
|
Test Report | Test Report | 1.68 MiB | May 28 2021 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 412.32 KiB | May 28 2021 / November 24 2021 | delayed release |
1 | User Manual | Users Manual | 874.38 KiB | May 28 2021 / November 24 2021 | delayed release |
USER MANUAL USER MANUAL RDS-32 SURVEY METER RDS-32 SURVEY METER NOTE This document and the information herewith are copyrighted material as mentioned in the Copyrights Act. No part of this document may be copied without a written authorization from the manufacturer. The manufacturer withholds the right to make changes in the contents of this document without prior notice. If you have any comments or suggestions for additions concerning either the products or this document, please submit your feedback as instructed at the end of the manual. ATTENTION The RDS-32 Radiation Survey Meter does not contain any hazardous or dangerous substances and can be recycled accordingly. The batteries of the device must be recycled separately as instructed by the manufacturer of the batteries. Copyright Mirion Technologies (RADOS) Oy 2020 Document No. 2093 10097 Version 1.1 Issue date 14.4.2021 USER MANUAL RDS-32 SURVEY METER 1 INTRODUCTION ............................................................................. 1 1.1 1.2 RDS-32 SURVEY METER FAMILY ................................................................... 1 RDS-32 VARIANTS ........................................................................................... 2 2 GETTING STARTED ....................................................................... 3 OVERVIEW OF THE METER ............................................................................ 3 INSERTING BATTERIES .................................................................................. 4 POWER ON/OFF ............................................................................................... 5 OPERATING DISPLAY AND SYMBOLS ........................................................... 6 NAVIGATION AND SHORTCUTS ..................................................................... 9 CONNECTING EXTERNAL PROBE ................................................................ 10 3 RDS-32 MENU ITEMS ................................................................... 10 POWER OFF ................................................................................................... 11 DOSE .............................................................................................................. 12 DOSE RATE .................................................................................................... 12 CHIRP ............................................................................................................. 13 ALARMS .......................................................................................................... 14 3.5.1 DOSE RATE ALARM (DRATE) .................................................................... 14 3.5.2 DOSE ALARM .............................................................................................. 15 3.5.3 EXTERNAL DOSE RATE / COUNT RATE ALARM ...................................... 16 HISTOGRAM ................................................................................................... 16 3.6.1 CLEAR ......................................................................................................... 17 3.6.2 STATE .......................................................................................................... 17 3.6.3 INTERVAL (I) ................................................................................................ 18 3.6.4 LOCATION (L) .............................................................................................. 18 3.6.5 MANUAL....................................................................................................... 18 CONNECTIONS .............................................................................................. 18 3.7.1 WRM ............................................................................................................ 19 3.7.2 BLE ............................................................................................................... 19 3.7.3 NFC .............................................................................................................. 19 DIAGNOSTICS ................................................................................................ 20 PROBES.......................................................................................................... 20 4 ERROR CODES AND OTHER DISPLAY MESSAGES ................. 21 LOW BATTERY WARNING ............................................................................. 21 LOW BATTERY ALARM .................................................................................. 21 DOSE RATE / DOSE ALARM (BLINKING DISPLAY) ...................................... 21 2.1 2.2 2.3 2.4 2.5 2.6 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.1 4.2 4.3 4.4 4.5 DOSE RATE OVERFLOW ALARM (OFL) ....................................................... 22 DEFECT ERRORS .......................................................................................... 22 5 MAINTENANCE AND DECONTAMINATION ................................ 23 FIRMWARE UPDATE ...................................................................................... 23 5.1 BATTERY COVER AND SEAL CHANGE ........................................................ 23 5.2 5.3 CALIBRATION ................................................................................................. 23 5.4 MECHANICAL DECONTAMINATION .............................................................. 23 CHEMICAL DECONTAMINATION ................................................................... 24 5.5 6 SPECIFICATIONS ......................................................................... 24 7 ACCESSORIES AND PROBES .................................................... 31 7.1 7.2 ACCESSORIES ............................................................................................... 31 COMPATIBLE PROBES .................................................................................. 32 FEEDBACK ......................................................................................... 36 INTRODUCTION INTRODUCTION 1.1 RDS-32 SURVEY METER FAMILY The RDS-32 Survey Meter continues the survey meter line of Mirion Technologies by offering modern design and versatile functionalities for radiation measuring applications. RDS-32 is a small handheld, battery-operated radiation survey instrument. Models RDS-32 and RDS-32iTx utilize an energy-compensated GM-tube as primary detector. RDS-32WR and RDS-32iTxWR offer an extended measurement range by addition of a silicon diode detector. RDS-32iTx and RDS-32iTxWR models are equipped with an internal radio module enabling the dose/dose rate data transmission to any WRM compatible system. Additionally, but not featured in this manual, the product family includes RDS-32iTxSD variant for specialized long-
term monitoring applications. RDS-32 is suited for a wide range of applications in civil defense, industrial use, nuclear power plants, laboratories etc. CSW-32 Configuration Software can be used to easily optimize the behavior of the instrument to meet various working conditions and needs. With the CSW-32 user can define menu functions available on the meter itself from the bare essentials to a full functioning menu including alarm limit setting. RDS-32 features excellent ergonomics; it is lightweight and easy to handle with visual and audible alarms and a built-in vibrating alarm. The instrument can be handled firmly even under difficult conditions thanks to the rubber grip around the instrument. The large graphic display can be easily read both in total darkness and in direct sunlight. The display additionally includes a tilt sensor enabling display rotation in menu mode. RDS-32 can be operated with a single key (on/off) or taking advantage of the 4-way menu navigation. To facilitate easy operation of the instrument, shortcut functions have been configured to the arrow keys and marked with corresponding symbol. The predefined shortcuts include backlight activation, accumulated dose display and a mute function. With configuration software users can also customize the shortcut keys. RDS-32 features both Bluetooth and NFC connectivity. A dedicated smart phone application is provided for changing meter settings and accessing measurement data. RDS-32 offers versatile possibilities to measure other types of radiation by using external probes. These detectors include an extensive range of CSP (Canberra Smart Probe) probes for gamma, alpha, beta and neutron measurements in various applications. The compatible probes also include GMP-12 series external gamma probes and GMP-25, ABP-150 and GMP-
11-3/15-3 probes for alpha/beta contamination measurements. The various detectors can be added to the instrument using a connecting cable or an adapter cable. This provides users an easy and cost-effective way to extend their measuring capabilities. The meter provides an additional protective function to the user: while using external probes, the meter simultaneously measures and displays the dose rate from the internal detector of the instrument. This allows the alarm to be triggered in case a too high dose rate or an accumulated dose is measured. 1 INTRODUCTION 1.2 RDS-32 VARIANTS The RDS-32 variants are available either in Sv-units or in rem-units. 1 2 3 4 For more information see the back label of the meter and the detailed specifications in Chapter 6 SPECIFICATIONS. 2 RDS-32 with BLACK front frame includes two variants for different dose rate areas 1 2 RDS-32 for max dose rate 100mSv/h RDS-32WR for max dose rate 10Sv/h WR is marked on the upper right corner of front frame iTx variants have a distinctive frame color. These variants include an internal radio and can be used in WRM compatible systems. iTx is marked on the upper right corner of front frame. 3 4 YELLOW for max dose rate 100mSv/h BLUE for max dose rate 10Sv/h WR is marked on the upper right corner of front frame GETTING STARTE GETTING STARTED 1.3 OVERVIEW OF THE METER The RDS-32 is lightweight and is ergonomically designed for handheld use. Navigation keys are placed above the large display, and the rubber grip around the meter enables handling in all conditions. In menu mode the display tilts to ensure easy navigation. Enclosure class is IP67, including battery compartment. For performance characteristics, check the RDS-32 variant specification. RDS-32 front view A. RDS-32 bottom view E. B. F. Dimensions L x H x W 116 x 72 x 32 mm
(4.57 x 2.83 x 1.26 in) C. C. D. 3 A. Navigation keys with shortcuts, Menu/Select key (ON/OFF) in the middle B. Visual alarm C. Binder connector with protective cap for external probes, cable connections and external alarming devices D. Charging contacts E. Fixing lug for the wrist strap F. Additional information if the meter is WR or iTx variant. Detector positions for GM-tube or both detectors depending on the variant. Observe the markings on the meter, which show the position of the detector(s). GETTING STARTE 1.4 INSERTING BATTERIES The instrument uses two IEC (LR6/ HR6) AA-size batteries. The use of alkaline batteries is recommended, but rechargeable NiMH batteries can also be used. Open the battery compartment using a Pozidriv #1 screwdriver. Observe the correct polarity of the batteries. 4 GETTING STARTE 1.5 POWER ON/OFF POWER ON the device by pressing the Menu/Select key for two seconds. The firmware version, time and calibration status are first shown on the display. In case the time of meters Real Time Clock is not set, the flashing TIME NOT SET message is displayed. The Real Time Clock can be set with configuration software. After the initialization phase is complete the operating screen with dose rate is displayed. 5 When switched on the meter performs a self-test function:
All the display pixels are turned on The buzzer is activated The vibration is activated The display backlight is switched on The battery condition is tested The HV-generator is tested POWER OFF the device by pressing the Menu/Select key so that the PWR OFF selection is activated. Press the Menu/Select key again for 3 seconds to POWER OFF the device. GETTING STARTE Pressing the Menu/Select key, a counter will emerge to guide the user. If the user releases Menu/Select key before the counter is completed the device will return to menu selection screen. 1.6 OPERATING DISPLAY AND SYMBOLS After initialization phase the operating screen with dose rate is displayed. The symbols visible on the operating display depend on the status of meter. The basic instrument RDS-32 has two units: Sv-based and rem-based units. A suitable sub-
multiplier or m is set to extend the display range. In addition, /h is applied to indicate the dose rate. With external probes, additional units can be provided in the display, depending on the external detector. 6 GETTING STARTE With external gamma detectors, the same basic units can be used (Sv/h, Sv, rem/h and rem). With external contamination detectors, the display can be configured to units (cps, cpm, dpm, Bq or Bq/cm2). The selected unit is indicated above the reading. While using external probes, RDS-32 simultaneously measures and displays the dose rate from the internal detector of the instrument (bottom left corner of the display). The external readings are marked according to the type of radiation measured. Display with alpha/beta probe:
Display with gamma probe:
DISPLAY SYMBOLS AND THE RELATED FUNCTIONS:
Display symbols for audio and alarming functions Audible chirp enabled Audible chirp disabled Vibration alarm is enabled AL Alarm condition exists Button and alarm buzzer enabled Button buzzer disabled, alarm buzzer enabled Button buzzer enabled, alarm buzzer disabled Button and alarm buzzer disabled NOTE: If speaker and chirp symbols are not visible, device is muted. 7 GETTING STARTE Display symbols for external detectors Waiting for external detector detection Alpha detector measuring Gamma detector measuring (and internal detector measurement) EXT n External detector is connected Beta detector measuring Neutron detector measuring Display symbols for battery status Battery full Powered from USB or cradle. Alternates with battery capacity symbol in two second intervals. Display symbols for communication Bluetooth NFC 50% capacity (changes showed in steps of 10%) Battery life indicator blinks on the left side of battery symbol WRM transmission active NOTE: Battery monitoring is for alkaline batteries. Analog bar is shown at the bottom of the display:
The graph indicates very short integration time pulse rates and helps in searching. 8 GETTING STARTE 1.7 NAVIGATION AND SHORTCUTS Navigation in the RDS-32 menu:
ENTER the menu by pressing the MENU/SELECT key. SCROLL DOWN in the menu using the UP and DOWN arrow keys. MOVE into a menu section by pressing the RIGHT arrow key. SELECT an item by pressing the MENU/SELECT key. RETURN to a higher level in the menu by pressing the LEFT arrow key SET a value, SELECT a function, or RESET a counter by pressing the MENU/SELECT key. The parameters of the instrument can be changed using the menu functions described later in this manual. The configuration software is required to change those parameters that are either disabled from the Instrument Menu or are included only in the software. Almost all the menu functions can be disabled with the software. Display automatically returns to the operating display if keys are not pressed for 14 seconds. Predefined shortcut functions of the RDS-32:
Backlight on for 15 seconds Mute/Unmute active alarm and chirp DOSE Checking accumulated dose No predefined shortcut The top arrow key does not have a predefined shortcut. The user can define a shortcut for this key with configuration software. The user can also change the predefined shortcut functions with configuration software. 9 1.8 CONNECTING EXTERNAL PROBE To connect the external probe to the meter, first remove the rubber protection cap of the connector by pulling the cap out. Connect the external probe by carefully inserting the probe connector and then turn the fixing sleeve clockwise until firmly fastened. RDS-32 MENU IT The probe can be attached to or removed from the meter without any need to switch off the meter first. Most probes are detected automatically, and the radiation detection starts immediately without any need for input. Probe menu opens when detector with no memory is connected to the meter. For detailed probe settings see Chapter 3.9 Probes. RDS-32 MENU ITEMS Quick guide to menu items is provided below. For detailed operation, see the individual chapters for each item. MENU ITEM FUNCTION PWR OFF Switching off the meter DOSE Check and reset the current accumulated dose value DRATE CHIRP ALARM HISTO CONN DIAG Check and reset the current maximum recorded dose rate since last reset Adjust the sensitivity of the visual and audible pulse indication Dose and dose rate alarm settings Operate the Histogram functions and/or pick manually the current data values into the memory NFC, Bluetooth and WRM connection settings Activate the internal diagnostics, check software revision and battery capacity PROBE Settings for external probes 10 1.9 POWER OFF POWER OFF the device by pressing the Menu/Select key so that the PWR OFF selection is activated. Press the Menu/Select key again for 3 seconds to power off the device. RDS-32 MENU IT Pressing the Menu/Select key, a counter will emerge to guide the user. If the user releases Menu/Select key before the counter is completed the device will return to menu selection screen. The instrument does not completely shut down all the internal circuitry. The RTC-circuit remains active maintaining the time signal. The energy is supplied with the batteries. The time setting of the instrument RTC is lost in case the batteries are removed for more than 1 minute. In case the instrument is to be stored for a prolonged period, it is advisable to remove the batteries to prevent any leakage to the battery compartment. 11 RDS-32 MENU IT 1.10 DOSE The instrument integrates the cumulative dose continuously when switched on. The cumulative dose can be viewed by pressing the DOSE shortcut key or by entering the menu. To reset accumulated dose, navigate to DOSE in the main menu and select RESET by pressing the Menu/Select key. The date/time of the dose reset is recorded and shown in the menu. 1.11 DOSE RATE The instrument monitors maximum dose rate while measuring. The maximum recorded dose rate can be viewed by entering the menu. To reset maximum recorded dose rate, navigate to DRATE in the main menu and select RESET by pressing the Menu/Select key. The date/time of the maximum dose rate reset is recorded and shown in the menu. 12 RDS-32 MENU IT 1.12 CHIRP The chirp function can be used to activate or deactivate the audible or visual chirp and to select the Chirp divisor. The possible divisors are: 1/1, 1/2, 1/5, 1/10, 1/20 and 1/50. The audible and visual Chirp can be disabled individually, but they share the common dividing ratio when enabled. To see or change the chirp state navigate CHIRP in the RDS-32 menu. The menu shows A:ON or A:OFF depending on the current state of the Audible Chirp. The menu shows LED:ON or LED:OFF depending on the current state of the Visual Chirp. To change the divisor of the chirp function navigate to SCALE. 13 RDS-32 MENU IT 1.13 ALARMS ALARM menu selection includes the following items:
Dose rate Dose TimeToDose: the remaining time is visible Mode Selection structure and logic to set the dose rate or dose levels are similar for both and described in below chapters. Alarm mode (fixed or dual, fixed is default) can be changed with configuration software. 1.13.1 DOSE RATE ALARM (DRATE) Dose rate alarm can operate in two different modes Fixed alarm Dual alarm (different level is set for WARNING and ALARM) Default mode is fixed alarm. The mode can be changed only with configuration software. User can choose the fixed alarm threshold level from the 8 preset levels for dose rate alarm:
DISABLED, 10, 50, 100, 500, 1000, 5000, 10000, 50000 Sv/h or mrem/h The preset levels can be changed with configuration software. To see the current dose alarm level or change it, navigate to ALARM in the menu. 14 RDS-32 MENU IT On Dose Rate press the right arrow key and navigate further to right to modify alarm level. The alarm level is modified using the top and bottom arrow keys and moving to right / next figure once ready. The measuring unit is modified the same way. The alarm level can be defined in format 000.0 and units can be selected from Sv/h, mSv/h or Sv/h (rem/h, mrem/h, rem/h). Alarm level is updated only if Save is selected using the Menu/Select key. To ignore the change, select Undo or press the left arrow key until returned to previous menu level. Also waiting 5 seconds will switch the display back to operating mode with no change to the alarm level. 1.13.2 DOSE ALARM Dose alarm can operate in two different modes Fixed alarm Dual alarm (different level is set for WARNING and ALARM) Default mode is fixed alarm. The mode can be changed only with configuration software. User can choose the fixed alarm threshold level from the 8 preset levels for dose rate alarm:
DISABLED, 100, 500, 1000, 5000, 10 000, 50 000, 100 000 or 500 000 Sv or mrem. The preset levels can be changed with configuration software. To see the current dose alarm level or change it, navigate to ALARM in the menu. Press right arrow key, navigate to Dose and navigate further to right to modify dose alarm level. The alarm level is modified using the top and bottom arrow keys and moving to right / next figure once ready. The measuring unit is modified the same way. The alarm level can be defined in format 000.0 and units can be selected from Sv, mSv or Sv (rem, mrem, rem). Alarm level is updated only if Save is selected using the Menu/Select key. To ignore the change, select Undo or press the left arrow key until returned to previous menu level. Also waiting 5 seconds will switch the display back to operating mode with no change to the alarm level. 15 RDS-32 MENU IT 1.13.3 EXTERNAL DOSE RATE / COUNT RATE ALARM The external alarm is dependent of the connected probe. For dose rate detectors the alarm is dose rate alarm and for count rate detectors the alarm is count rate alarm. User can choose any of the preset 8 alarm levels listed below. Disabled, 10, 50, 100, 500, 1 000, 5 000, 10 000 or 50 000 Sv/h or mrem/h. Preset levels for dose rate alarm:
Preset levels for count rate alarm:
1.14 HISTOGRAM Disabled, 10, 15, 20, 60, 100, 600, 1000 or 6000 cps. The default setting in the RDS-32 is that the histogram is ON and collecting data at a 5 minute interval. The meter memory is able to store approximately 60000 data sets. The information stored is the immediate value in the display, the average and maximum dose rate from the previous storing, the location and time. When an external detector is connected to the instrument, the histogram stores data from both internal and external detector. The final number of stored data sets depends on the amount of diagnostics information that is also stored into the same memory area. The histogram memory is downloaded using the configuration software and communication link. It will take approximately 80 hours to fill the RDS-32 histogram memory when sampling at 10 second intervals. If the histogram memory becomes full the older data sets will be overwritten by new data sets. In addition to the type of data sets mentioned above there are automatic records that are stored into histogram memory:
Diagnostics (Automatic, manual or error found) The user has reset the dose or the max dose rate The instrument has been calibrated (New and old Coefficients are stored) These data records also consume the histogram memory. Calibration memory: The results of the 64 newest calibrations are stored in the memory. The oldest are overwritten in case more than 64 calibrations are performed. Diagnostics memory: The first start-up of the day is stored here. In case the instrument operates continuously without going to the OFF state, automatic diagnostics is run at 00:00:00 and the results are stored into a specific diagnostics memory. This memory can store the data 16 of over one year of operation. When the memory becomes full, the oldest diagnostics data is overwritten. These special memory areas cannot be cleared with the configuration software but require special service. RDS-32 MENU IT The histogram memory can be cleared by selecting Clear in the HISTO menu. 1.14.1 CLEAR 1.14.2 STATE The current state of the histogram data collection can be checked and changed ON/OFF in the STATE menu. NOTE: With configuration software user can configure the instrument to automatically save histogram data when alarm conditions are met, although the histogram STATE would be set to OFF. See the software manual for more details 17 RDS-32 MENU IT 1.14.3 INTERVAL (I) 1.14.4 LOCATION (L) The interval of storing measurement results to the histogram can be selected from the predefined list in this menu by pressing the Menu/Select key. The intervals available are 10 s, 30 s, 1 min, 5 min, 10 min, 30 min, 1 h and 2 h. A location can be stored as additional information to the histogram. There are up to 255 numbered locations. The location 0 is a general-purpose placement. Using the RDS-32 configuration software it is possible to specify a mnemonic or longitude and latitude values for the first 16 locations. By selecting Manual, the user can save the current values displayed by the meter into the histogram. 1.14.5 MANUAL 1.15 CONNECTIONS 18 RDS-32 MENU IT 1.15.1 WRM WRM (Wireless Remote Monitoring) functionality can be enabled with configuration software. The WRM communication uses either internal WRM-radio in applicable models or serial line wired connection. The WRM can be set OFF or to send messages in intervals between 2 seconds to 2 hours. The WRM functionality is used to send data packets via radio system, RS communication or over Local Area Network. In RDS-32iTx variants an internal radio modem enables the dose/dose rate data transmission to any WRM compatible system. In RDS-32iTx variants the WRM setting are available in the menu as default. To activate the WRM communication in an RDS-32iTx variant:
Scroll to WRM in the menu and check the current state of the communication link
(WRM: xs | WRM:OFF ). Change WRM ON/OFF and send interval as needed. 1.15.2 BLE 1.15.3 NFC BLE communication can be configured in the BLE menu. The user can manually activate BLE enumeration for 30 s or use NFC pairing. The user can also disable to BLE communication in this menu. NFC Pair => activated with NFC (Standby STBY) ON for 30s => Manual activate BLE enumeration active for 30 seconds OFF => Disable the BLE communication Basic device configurations can be performed via BLE interface by using dedicated Mirion application. The NFC Tag mode can be set ON when BLE communication is initiated with NFC reader or OFF when BLE communication needs to be initiated via BLE menu selection, see 1.15.2. Tag mode ON/OFF 19 RDS-32 MENU IT 1.16 DIAGNOSTICS The user can manually activate the meter self test in the DIAG menu. The DIAG menu also contains information about the device firmware version and the time and date set to the RDS-32. The time and date can be set using the configuration software. The firmware can also be updated using configuration software. See the software manual for more details. Activate the meter self test routine by navigating into the DIAG menu and by pressing Menu/Select on Self test. The self test routine includes checking the high voltage, the operating voltage and the battery capacity. During this process the user may also check the operation of all the display pixels, the visual alarm LED, the audible alarm and the vibration alarm. Selecting CAL Check starts the calibration check procedure. The check dose rate value is set to 1 mSv/h as a default. With the configuration software, the value can be set to a more optimal value between 300 Sv/h - 3 mSv/h. After a fixed 1 minute waiting time the instrument measures a dose of 100 Sv (time calculated from the rate). In case the measured dose is within 10% from expected dose the check is cleared, otherwise there will be a warning and it is advised to perform a recalibration of the instrument. Start the calibration check procedure. The results of the check are stored into the Diagnostics histogram. 1.17 PROBES Most probes are detected automatically, and the radiation detection starts immediately without any need for input. Probe menu opens when detector with no memory is connected to the meter. From this sub-
menu it is possible to change the detector profile, unit for external detector. For isotope profile detectors there is the possibility to change the used isotope. It is also possible to change radiation type for detectors that are capable to detect different radiations. Gen.CHK.Def is profile for no-memory detector that is tested for the pulse generation of the external probe. If no pulses are detected for a given time the meter will show error message. 20 Gen.No.Def is profile for no-memory detector that is not tested for pulse generation. For instance alpha probes, and there are no pulses at all (some of the probes are alpha sensitive only) in the determined time window. ERROR CODES AN ERROR CODES AND OTHER DISPLAY MESSAGES When necessary the meter will give display messages regarding battery condition, current alarms, and error situations. 1.18 LOW BATTERY WARNING An audible low battery warning signal combined with a blinking battery symbol indication repeated every 6 minutes when the battery capacity is 10% < Capacity < 30%
Low battery warning: _______ _ _______ (Long Short Long Bleep in five minutes intervals). The dose rate measurement continues normally. 1.19 LOW BATTERY ALARM The display shows "LOBAT" blinking and the audible alarm is activated when the battery capacity is <10%. Low battery alarm: _______ _ _______ (Long Short Long Bleep in 20 second intervals). NOTE: The dose rate measurement is prevented. 1.20 DOSE RATE / DOSE ALARM (BLINKING DISPLAY) Dose rate alarm: ------ (two beeps per second). The dose rate display is blinking, and the continuous audible alarm is on. The audible alarm can be silenced with mute shortcut (right arrow key). Dose alarm: - - - - - - (one beep per two seconds). The dose rate display is on and the current dose alarm level alternates in the display and the continuous audible alarm is on. The audible alarm can be silenced with mute shortcut (right arrow key). 21 ERROR CODES AN 1.21 DOSE RATE OVERFLOW ALARM (OFL) When the measurement limits are exceeded, the display shows OFL (blinking). The continuous audible alarm is on. Dose rate overflow: ____ ____ (continuous beeps). The overflow alarm cannot be reset. NOTE: When the dose rate overflow has been activated, there will be a message from this event in the dose read-out. When the dose is given, the display alternates between DR.OFL <-> dose. This flag will be set when the dose is reset. This is to inform the user that the measured dose might not give the true value due to exceeding the maximum measurable dose. 1.22 DEFECT ERRORS In case there is a critical internal failure in the instrument, the Defect error is activated. The continuous audible alarm is on. Error alarm: _______ _______ (continuous bleeps every two seconds). The dose rate measurement is prevented. Error codes and types:
Error1 = CAL.DF Calibration error, the calibration coefficient is default, or is out of accepted limits. Error2 = FLS.DF Non-volatile memory error Error3 = DET.DF Detector is faulty (internal or external) Error4 = DG1.DF High voltage is not within specified range Error5 = DG2.DF Internal power supply is out of specified range Error6 = DG3.DF Firmware CRC error; the bit sum check of embedded software failed Error7 = LFE.DF Cumulative dose overflow (>10 Sv). The GM-detector can be at the end of life. Should an error occur, write down the Error message and return the meter to the manufacturer for service (for contact info: see the last page of this manual). The internal diagnostics memory will also store critical errors, but in case the problem is the memory itself, it cannot be completed. 22 MAINTENANCE AN MAINTENANCE AND DECONTAMINATION No specific maintenance is required except for a periodic check of the calibration. The local authorities typically determine the required checking interval. Once a year under demanding conditions, or every second year under typical laboratory conditions is a recommended interval in maintaining the proper operational reliability of the instrument. 1.23 FIRMWARE UPDATE Configuration software is needed for firmware update. Follow the procedures outlined in the software manual to upload a new firmware to the RDS-32. 1.24 BATTERY COVER AND SEAL CHANGE For battery cover and seal change a replacement cover or seal and a Pozidriv #1 screwdriver are needed. Instructions:
Unscrew the battery cover from the meter Pull the rubber seal from the plastic cover. Attach the new rubber seal to the plastic cover. Make sure that the tips in the plastic are in the holes of the seal and the seal is well aligned. Screw the battery cover to the meter. 1.25 CALIBRATION Configuration software is needed for the calibration of RDS-32. Follow the calibration procedure outlined in the software manual. 1.26 MECHANICAL DECONTAMINATION The recommended mechanical method is vacuum cleaning or blasting with pressurized air. 23 SPECIFICATIONS 1.27 CHEMICAL DECONTAMINATION During the decontamination procedure following items are needed:
Cleaning solution with neutral pH (non-corrosive preferred) Cotton pad, paper tissue, etc. In principle the RDS-32 can be decontaminated with any commercially available decontamination solutions, suitable for polycarbonate/polyamide materials (e.g. Sprint 200 Free PH 7). Acetone is not recommended. Begin with wiping and/or brushing. Immersion is only recommended as a next step if necessary and the IP67 sealing has been confirmed. Please see service manual or ask factory for more advices about immersing the RDS-32 in a decontamination solution. SPECIFICATIONS DETECTOR:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR DETECTOR 1 Energy Compensated Geiger Mueller. SENSITIVITY (137Cs) 1.5 c/s per 1 Sv/h
(manufacturer spec 18 cpm per mR/h, 60Co) YES YES YES*
YES*
DETECTOR 2 Energy Compensated SI diode. SENSITIVITY (137Cs) 16 cps / 1mSv/h NO NO YES*
YES*
* Changing from G-M to Si diode takes place at 30 mSv/h in increasing field and back from Si diode to G-M tube at 10 mSv/h in decreasing field. 24 SPECIFICATIONS RADIOLOGICAL CHARACTERISTICS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR Operational quantity Ambient dose equivalent H*(10) Ambient dose equivalent H*(10) Ambient dose equivalent H*(10) Ambient dose equivalent H*(10) Radiation detected: gamma and X-rays: Low 48 keV 48 keV 55 keV 65 keV**
55 keV 65 keV**
Radiation detected: gamma and X-rays: High 3 MeV 3 MeV 3 MeV 3 MeV Dose rate measurement range 0.05 Sv/h .. 100 mSV/h 0.005 mrem/h .. 10 rem/h 0.05 Sv/h .. 100 mSV/h 0.005 mrem/h .. 10 rem/h 0.05 Sv/h .. 10 SV/h 0.005 mrem/h .. 1000 rem/h 0.05 Sv/h .. 10 SV/h 0.005 mrem/h .. 1000 rem/h IEC Dose rate measurement range: Low 0.3 Sv/h 0.03 mrem/h 0.3 Sv/h 0.03 mrem/h 0.3 Sv/h 0.03 mrem/h 0.3 Sv/h 0.03 mrem/h IEC Dose rate measurement range: High 100 mSv/h 10 rem/h 100 mSv/h 10 rem/h 10 Sv/h 1000 rem/h 10 Sv/h 1000 rem/h Dose measurement range: Low 0.1 Sv 0.01 mrem 0.1 Sv 0.01 mrem 0.1 Sv 0.01 mrem Dose measurement range: High 10 Sv 1000 rem 10 Sv 1000 rem 10 Sv 1000 rem 0.1 Sv 0.01 mrem 10 Sv 1000 rem Calibration accuracy at reference calibration direction and in the Cs-137 calibration field, temperature +20 C (68F). Compared to Finnish National Laboratory STUK 5% @137Cs 5% @137Cs 5% @137Cs 5% @137Cs Dose rate linearity 15% least significant number 0.3 Sv/h...0.1 Sv/h 15% least significant number 0.3 Sv/h...0.1 Sv/h 15% least significant number 0.3 Sv/h...10 Sv/h 15% least significant number 0.3 Sv/h...10 Sv/h Variation of the response due to photon radiation energy and angle of incidence
(R E,A) 71% < RE,A <
167% (48 keV...3 MeV), 45
(R E,A) 71% < RE,A <
167% (48 keV...3 MeV), 45
(R E,A) 71% < RE,A < 167%
(48 keV 65 keV*...3 MeV), 45
(R E,A) 71% < RE,A <
167% (48 keV 65 keV*...3 MeV), 45
**for Si diode detector above 30 mSv/h dose rates 25 SPECIFICATIONS FUNCTIONAL CHARACTERISTICS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR 4 navigation keys and a Menu/Select key to operate the instrument. 3 default shortcuts: Backlight, Mute and Dose. One user defined shortcut. Configurable units: Sv(/h), rem(/h), with external detectors Gy(/h), cps, cpm, dpm and Bq. Versatile histogram functions (dose rate, dose, diagnostic logging depending on configuration, time stamp, optional location control for mapping and repeating room control analysis). YES YES YES YES Histogram data stored in XML format; allowing additional histogram analyzing capabilities when downloaded from CSW-31 software to a spreadsheet. Real Time Clock (RTC) function. Back-up time 3 hours Configurable audible, visual and a vibration alarm. Graphical LCD display with 128 x 64 square pixels; special symbols for alarm, external probe, battery, RF communication, vibration alarm, chirp and mute. YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES 26 SPECIFICATIONS COMMUNICATION PROTOCOLS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR USB-communication with suitable adapter. YES YES YES YES Bluetooth Low Energy 4.2 protocol, BLE Class 2 communication. Three telemetry data channels including dose rate and dose (1 x internal and external probe with two channels). Basic device configurations can be performed via BLE interface by using dedicated Android application. YES YES NFC communication. BLE pairing by using NFC. YES YES YES YES YES YES WRM radio 900 MHz or 2.4GHz. Max emitting Tx Power:
- 298mW@900MHz
- 86mW@2.4GHz NO YES NO YES Graphical display with 128 x 64 square pixels; special symbols for alarm, external probe, battery, RF communication, vibration alarm, chirp and mute. YES YES YES YES 27 SPECIFICATIONS ELECTRICAL CHARACTERISTICS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR Batteries 2 x AA/LR6, alkaline or NiMH
- Battery monitoring not working with rechargeable lithium batteries 2 x AA/LR6
(alkaline or NiMH) 2 x AA/LR6
(alkaline or NiMH) 2 x AA/LR6
(alkaline or NiMH) 2 x AA/LR6
(alkaline or NiMH) Contacts for external power and charging of NiMH battery (charging conditions +5... +35C). YES YES YES YES Operation time with fresh batteries more than 2 months at background radiation at +23C, 8 h use/24h. Operation time with fully charged NiMH batteries more than 1 month at background radiation at
+23C, 8 h use/24h with 2900 mAh capacity. (radios disabled, display backlight off, LED off) YES YES YES YES YES YES YES YES Battery life ca. 600 h (in backgroud radiation, radios disabled). Real time clock secured with back up battery 3 hours 3 hours 3 hours 3 hours Alarm audio Level in dB 86 dBA@30cm 86 dBA@30cm 86 dBA@30cm 86 dBA@30cm YES YES YES YES 28 SPECIFICATIONS MECHANICAL CHARACTERISTICS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR 116 x 72 x 32 mm
(4.57 x 2.83 x 1.26 in) 116 x 72 x 32 mm
(4.57 x 2.83 x 1.26 in) 116 x 72 x 32 mm
(4.57 x 2.83 x 1.26 in) 116 x 72 x 32 mm
(4.57 x 2.83 x 1.26 in) 160 g 170 g 195 g 205 g Dimensions Weight without batteries Weight with batteries 210 g 220 g 245 g 255 g Enclosure class, including battery compartment. IP67 (IEC 60529) IP67 (IEC 60529) IP67 (IEC 60529) IP67 (IEC 60529) Case high impact durable PA6 Grilon EG30 glass fiber reinforced polymer. Tested 6 drops from 1 meter hight to concrete floor (once for each face). Ergonomic design, rubber grip and cushion around the case. YES YES YES YES YES YES YES YES Wrist strap Belt clip YES YES YES YES YES YES YES YES 29 SPECIFICATIONS ENVIRONMENTAL CHARACTERISTICS:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR
-25 C...+60 C
(-13 F to 140 F)
-25 C...+60 C
(-13 F to 140 F)
-25 C...+50 C
(-13 F to 122 F)
-25 C...+50 C
(-13 F to 122 F)
-40 C...+70 C
(-40 F to 158 F)
-40 C...+70 C
(-40 F to 158 F)
-40 C...+70 C
(-40 F to 158 F)
-40 C...+70 C
(-40 F to 158 F) Operating temperature Storage temperature Relative humidity
+10% to 85% at +35 C
(95 F)
+10% to 85% at +35 C
(95 F)
+10% to 85% at +35 C
(95 F)
+10% to 85% at +35 C
(95 F) RF-immunity. Fulfills following standards: IEC61000-4-2 (2008), IEC61000-4-3 (2006 +A1:2007 +
A2:2010), IEC61000-4-6 (2013), IEC61000-4-8 (2009) YES YES YES YES YES YES YES YES RF Emissions. Fulfills following standards: EN55032B 2AHI8-RDS-32 2AHI8-RDS-32 2AHI8-RDS-32 2AHI8-RDS-32 26167-RDS32 26167-RDS32 26167-RDS32 26167-RDS32 CONNECTOR:
RDS-32 RDS-32 iTx RDS-32 WR RDS-32 iTx WR Binder-702-series Binder-702-series Binder-702-series Binder-702-series FCC approval IC approval Probe connector Existing detectors In separate list In separate list In separate list In separate list External alarm output max. 24 V YES YES YES YES Available accessories and ordering codes: See related chapter in User Manual 30 ACCESSORIES AN RDS-32 VARIANTS AND ORDERING CODES:
Part no. 1233-321 RDS-32S SURVEY METER Part no. 1233-322 RDS-32R SURVEY METER Part no. 1233-323 RDS-32S WR SURVEY METER Part no. 1233-324 RDS-32R WR SURVEY METER Part no. 1233-325 RDS-32iTxS SURVEY METER (2.4GHz) Part no. 1233-326 RDS-32iTxR SURVEY METER (900MHz) Part no. 1233-327 RDS-32iTxS WR SURVEY METER (2.4GHz) Part no. 1233-328 RDS-32iTxR WR SURVEY METER (900MHz) The variant with Sievert-units is marked with S and the variant with rem-units with R. ACCESSORIES AND PROBES 1.28 ACCESSORIES PROBE CABLES:
Part no. 1241-251 Cradle for RDS-32 including power supply and wall mounting kit Part no. 1233-293 GMP-12SD/GSD/UW/GMP-25i coiled connection cable, 0,7 m - 1,6 m Part no. 1233-295 GMP-12SD/GSD/UW/GMP-25i straight connection cable, length 20 m Part no. 1233-318 RDS-32 - CSP probe adapter cable, length 0,4 m Part no. 1233-319 RDS-32 - CSP probe straight adapter cable, length 1,5 m Part no. 1233-320 RDS-32 - CSP probe coiled adapter cable, length 0,7 m - 1,6 m 31 ACCESSORIES AN SOFTWARE:
Part no. 1233-331 CSW-32 configuration software with USB Cable Link OTHER ACCESSORIES:
Part no. 1233-213 Telescopic Pole for RDS-32 (Incl. carrying strap) Part no. 1233-311 Carrying bag for telescopic pole 1.29 COMPATIBLE PROBES Part no. 1233-294 GMP-12GSD Gamma dose rate probe Part no. 1233-286 GMP-12SD Gamma dose rate probe Part no. 1233-287 GMP-12UW Gamma dose rate probe Part no. 1233-279 GMP-25 Alfa/Beta/Gamma pancake probe Part no. 1233-291 GMP-25i Alfa/Beta/Gamma pancake probe Part no. 1233-289 ABP-150 Alfa/Beta probe with 100 cm detection area Part no. 1233-274 GMP-11-3 Alfa/Beta/Gamma probe Part no. 1233-276 GMP-12-3 Gamma dose rate probe Part no. 1233-277 GMP-12L-3 Gamma dose rate probe Part no. 1233-278 GMP-12H-3 Gamma dose rate probe Part no. 1233-275 GMP-15-3 Alfa/Beta/Gamma pancake probe Part no. EM90062 SA-20-2 Alpha probe with 20 cm detection area Part no. EM75863 SA-100 Alpha probe with 100 cm detection area Part no. EM74672 SB-20 Beta probe with 20 cm detection area Part no. EM78627 SX-2R 1.5 x 3 mm X-Ray probe Part no. EM75864 SAB-100 Alpha/Beta probe with 100 cm detection area Part no. EM81933 SABG-100 Alpha/Beta probe with 100 cm detection area Part no. EM108330 Easy-Count Alfa/Beta PIPS smear holder Part no. EM75860 SG-1R 1" x 1" NaI(Tl) Gamma probe Part no. EM75861 SG-2R 2" x 2" NaI(Tl) Gamma probe Part no. EM78766 SPAB-15 Alpha/Beta 15 cm probe with PIPS detector 32 ACCESSORIES AN Part no. EM83023 STTC Wide Range Gamma probe Part no. EM85916 SABG-15+ Alpha/Beta/Gamma pancake probe Part no. EM86790 SVLD Very Low Dose Rate Gamma probe Part no. EM108072 SN-D-2 Neutron Dose probe Part no. EM85810 SN-S Neutron Search probe Part no. EM95464 SABS-579 Alfa/Beta 579 cm Floor probe Part no. EM106271 SABP-525 Alfa/Beta 525 cm 33 FCC COMPLIANCE FCC COMPLIANCE STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Modifications: Any modifications made to this device that are not approved by Mirion Technologies Oy may void the authority granted to the user by the FCC to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver. is connected. Consult the dealer or an experienced radio/television technician for help. 34 IC COMPLIANCE IC COMPLIANCE STATEMENT This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dIn-novation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
1. Lappareil ne doit pas produire de brouillage;
2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est sus-ceptible den compromettre le fonctionnement. 35 FEEDBACK FEEDBACK We are continuously working hard at producing correct and easy-to-read technical documents. However, complex systems are often difficult to explain or understand and the documentation process. To correct these errors, we would like to hear your opinion on this document. inadequacies may occur occasionally therefore mistakes or in You can submit your feedback on our website www.mirion.com filling out the contact form. Alternatively, you can directly contact the manufacturing site for RDS-32:
Mirion Technologies (RADOS) Oy Mustionkatu 2 20750 Turku Finland Email: services.finland@mirion.com Tel.: +358 2 4684 600 Same contact information applies for all service-related matters. As standards, specifications and design are subject to change over a period of time, please request for the confirmation of the information given in this publication. For additional information on Mirion products and solutions please visit our webpage www.mirion.com. 36
1 | Label Information | ID Label/Location Info | 314.32 KiB | May 28 2021 |
RDS-32iTx(900MHz) WR Survey Meter Radiation: y and x-rays External probes: a, 8, y, n SNr. BS Effective Range:
0.3 uSv/h - 10 Sv/h/ 0.1pSv - 100 Sv 30 urem/h - 1000 rem/h / 10 urem - 10 krem Energy: H*(10), 48 keV - 3 MeV 65 keV - 3 MeV (>30 mSv/h) Angle: 0 to +45; reference from top of uae YAN T-Y AT-t:J[6) Operating environment: -10 - +40 C, IP 67 Center Key: ON / MENU / ENTER / OFF Arrow Key: Navigate / Shortcut: press > 2 sec bs EVES FCC ID: 2AHI8-RDS-32 contains FCC ID: 2AHI8-XB900HP a IC: 26167-RDS32 contains IC: 26167-XB900HP Mirion Technologies (RADOS) Oy 2 x AA (LR6 /HR6)
| Radiation: y and x-rays eit cel
| Effective Rang 0.3 pSv/h - 10 Sv/h/ 0.1p1Sv - ee Sv :
ON cn em Lee cola pean clued OL Cut HM @
Energy: H*(10), 48 keV - 3 MeV \ >
or VEC OST) . Nie) CO Cole toalCollcielae MICO ORM ec) Operating environment: -10 - +40 C, IP 67 ores Key: ON / MENU / ENTER / OFF Arrow Key: Navigate / Shortcut: press > 2 sec 3 ee (DE Gore geo 2atite-XBS00HP i MSP CuuN mr Miisect aac
(PLT Taso k eee ued ene a Lede
5 t re
1 | Agent Authorization Letter | Cover Letter(s) | 465.59 KiB | May 28 2021 |
M | 2 | O N Health Physics Division Mirion Technologies (RADOS) Oy Tel. +358-2-46 84 600 TECHNOLOGIES P.O.Box 506 Fax +358-2-46 84 601 Fl-20101 Turku www.mirion.com Date: 29" June 2020 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AHI8-RDS-32 To whom it may concern:
We, the undersigned, hereby authorize Mr. Markus Wallasvaara to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, | acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Mirion Technologies (RADOS) Oy This authorization is valid until further written notice from the applicant. Name: Lauri Sois Title: Managing Director Signature:
On behalf of Company: Mirion Technologies (RADOS) Oy Telephone: +358 2 4684613
1 | Applicant Declaration Letter | Cover Letter(s) | 529.29 KiB | May 28 2021 |
0'0:A2u uonedejoag juesjddy asegejep 994 ay] ul pays) uossed paziuoyjne ue Aq paubis aq jjeys jI jJuaby ue Aq paubls aq jouueo uoyesejoap SIV, :FLONs OL Jopolg Suseu oyesio "= rh ff OweN JUL aunyeuBbls jueoddy 1707 [dv 1s1Z
:9]eq
[WY"OE | LOJS/DUS/JSU}SD-}LUS/9}IS/919/E9 "9D 'OF MMM//-SANY :O0b-dSY 0} YUN]
Ufo XSPUl/Gpy/Jjo}s0/NOD Ooy sdde/-SdHY :sqqy oO} UIT Zp-S}-SUOHe|NbeJ-Sa|N/UOISIA|p-UO|}eAOUUI-pUe-SLO}SAS-So]b0|OU4OS}/SUOISIAIp-Neaing/SSe[ouIM/AOD Oo} MMWNY/-SGHY :SY4D 0} YUrT
"SUO}IPUOD pUe SLD} (GO1)dU| eOLAWIy UUON SOS au} Aq apiqe 0} seaube pue sjdacce poojsiepun peas sey jueoyddy ey} = (6 sasodind asayj 10} ,Ayed, 2 Jo UOMUYSp OU} JOY (q)ZOO7' | HAOLY 89S BOUL]SQNs paljOjUOD & JO UOIINLIsSIP JO UOISSassod JO} UO!JDIAUOD B Jo aSNedaq Z98 D'S'/N LZ 8B6L JO }OW esnay Bnig-HUY ey} Jo LOES UO!}D9S 0} JueNsund sjyeueq DO Sepnjoul yeu} s}Youq jeJapo~ jo e|Uap e 0} JOalqns si UoHeOI|dde au} 0} AWed Aue Jou jueol|ddy ayyseuyiou = (J
"SOS Aq payiyeo sjonpoid jo soue||lavuns pipne pue UO!}eoWS9O MAINS UO!}EN|eAS JO} pasInbas aremyos JO aJeMpseY JOJO JO SaLOSsa0oe aJeMYOS sajqeod ssolAap Yoddns |je apnjou! |jeys ajdwes ay, payonsjsul se GAS] Jo/pue 994 S$9DS 0} onpoid paysenbai ay} jo ajdwes uolonpoid e apiAoid asuadxe sjueolddy au} ye Sgs Aq sanbas uodn eys jueolddy eu () GAS Jo/pue 994 SOs Aq jsenbei uodn ajqejiene ajdwes uojonpold e aney sheme 0} SUOISIAOJd aye //eys jued|ddy au} (Zz) Buljsa} soue||iavins Jo} pejsenbei oq Aew ajdwes e yey} saeu6e pue s}deooe spuejsiapun jueolddy au} (1) s}UQWaUINbes aoue||IaAINS JayJeW }sod ay} Aq apige 0} seelbe pue s}dec0e poojsiapun peai sey jueoliddy ay} 00L-dSY PUB LZEPEEEGY 2001 9G DOJ E9LL/9GCM ODS S9OZLOSI UM aouepioooR Ul (8 LZEP6EAGM pue 606'Z YAO Ly Jepun payloads se saniiqisuodsa s1ay} Aq apiqe 0} ses6e pue Ayed ajqisuodsai ay} ase Aoy} yeu} }de00e 0} soaibe pue poojsuapun pea sey jueolddy au} }Zep~p6Egqy Pue 606'Z HAD Zy IM soURpIODe Ul (p sjUsWauINbad [2d|UY499} $,994 Bu} UM AjdWOo 0} snuNUOD ||I/M JUsUdINbe siuj Jo sun UONONpod yeu}
AINSUD 0} JaINJoeJNUeW dy} UJIM spew UdEq aAeY sjUsWebUeE o}eldoJdde juawdinba ay} jo Jounjoejnuew jenjoe ay} jou si juedddy eu si = (9 sans [ed1uyd9} a[qeol|dde au} yy JusWdinbs uj jo soueljduo09 = () sans ajqeorjdde ay} 0} juensind Buyjeqe| Juewaye}s souel|dwod = (Z) uoneordde siy} ul payloeds se G| O94 }oexe ay} U}IM JUsWdinbe ay} Buljeqe; (1) JO} a]qisuodsa s| Jueol|ddy au} uoeoldde siuj ul epeW SuO!ejUsseidad OU} JO }INSaJ e se OD-4 ay} Jo AoUNe ou} JapuN qo e Aq panss! UOHezZUOUINY JUsUdINby jo jueID e Buydeooe ul (q Joljoq pue aBpaymouy Aw JO ]S9q Bj 0} 9909 puke 9nd} aue OJaJaYy payoeye syiqiyxe ay} pue Ulalay SJUBWA}e}s BU} Jo [12 (P)LLE'TUAOZY UM BoURPIODOR Ul (2 faue|oep sJojasey} pue UedI|dd\y au} Jo} AtoyeuBbls pezuoujne ue we | yey} Ajeo pauBbisuepun au} |
19 V89P T 8SE+ | auoud JoeR}Uu0D Wd WOM @)o]esios] yey yoejUu0D oyesiog mney AL OWEN JOBJUOD pezuou ny ce-Sda-8IHVe dl S04 SIHVTE BPOD sajUelS) CNVINIA MINT OSLO 7 MeyUONsN] SsoJppy SO (SOGVYA) Salsojouysa], VOLTA aweN ssouisng jebe7 Jueoddy se]e}s peylun z00 eiGioay aauemns 00) SLINS peoYy 9ed}4YOe8dq PIO 029 uoljesej90qg jUeOIIddy OU| POLOLIY UON SOS
1 | Confidentiality Request | Cover Letter(s) | 236.75 KiB | May 28 2021 |
Health Physics Division Mirion Technologies (RADOS) Oy P.O.Box 506 FI-20101 Turku Tel. +358-2-46 84 600 Fax +358-2-46 84 601 www.mirion.com Mustionkatu 2 20750 Turku FINLAND Confidentiality Request regarding application for FCC ID: 2AHI8-RDS-32 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States To:
From: Mirion Technologies (RADOS) Oy Regarding:
LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Parts List / BOM The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within 180 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Markus Wallasvaara Quality Manager Mirion Technologies (RADOS) Oy
1 | Test Setup Photos | Test Setup Photos | 412.32 KiB | May 28 2021 / November 24 2021 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-05-28 | 2402 ~ 2480 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2021-05-28
|
||||
1 | Applicant's complete, legal business name |
Mirion Technologies (RADOS) Oy
|
||||
1 | FCC Registration Number (FRN) |
0025332966
|
||||
1 | Physical Address |
Mustionkatu 2
|
||||
1 |
506
|
|||||
1 |
Turku, N/A
|
|||||
1 |
Finland
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
u******@sgs.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AHI8
|
||||
1 | Equipment Product Code |
RDS-32
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L****** S********
|
||||
1 | Title |
Managing Director
|
||||
1 | Telephone Number |
+3582********
|
||||
1 | Fax Number |
+3582********
|
||||
1 |
l******@mirion.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Mirion Technologies (RADOS) Oy
|
||||
1 | Name |
M**** W********
|
||||
1 | Physical Address |
Mustionkatu 2
|
||||
1 |
506
|
|||||
1 |
Turku, 20101
|
|||||
1 |
Finland
|
|||||
1 | Telephone Number |
35824********
|
||||
1 | Fax Number |
35824********
|
||||
1 |
m******@mirion.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Mirion Technologies (RADOS) Oy
|
||||
1 | Name |
M******** W********
|
||||
1 | Physical Address |
Mustionkatu 2
|
||||
1 |
506
|
|||||
1 |
Turku, 20101
|
|||||
1 |
Finland
|
|||||
1 | Telephone Number |
35824********
|
||||
1 | Fax Number |
35824********
|
||||
1 |
m******@mirion.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 11/24/2021 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RDS-32 Survey Meter | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This grant supports portable use of a transmitter. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SGS Fimko Oy
|
||||
1 | Name |
J******** N******
|
||||
1 | Telephone Number |
+358 ********
|
||||
1 | Fax Number |
+358-********
|
||||
1 |
j******@sgs.eom
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 1M06F1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC