MOUNTING NOTE: This device is for commercial use only. It is not intended or suitable for any consumer applications. NOTE: This device requires professional installation to prevent tampering with or removal/replacement of the antenna by anyone other than qualified service professionals. OR Install the power supply and power up the Hub. Secure the power supply by wrapping the rubber flap around the connector and attaching into the opening on top of the Hub. Main Plug of the adapter acts as disconnect device, the socket-outlet shall be installed near the equipment and shall be easily accessible. Warning: The Adapter used must be marked with LPS or Limited Power Sources; otherwise those others are prohibited to use. La prise principale de ladaptateur agit comme un dispositif de dconnexion, la prise de courant doit tre installe prs de lquipement et doit tre facilement accessible. Avertissement: Ladaptateur utilis doit porter la mention LPS ou Sources dalimentation limites. sinon, ces autres sont interdits dutilisation. If using with MTI Connect application software, plug the Hub into the internet with an available Ethernet cable or setup with WIFI credentials. If not using with MTI Connect, move on to Freedom Micro Provisioning. MTI P/N 063-00210 rev D 2019 MTI All Rights Reserved 1 CONNECT HUB PRODUCT MANUALwww.mtigs.com | T:800.426.6844132 NETWORK PROVISIONING Ensure the Hub and all Freedom Micro positions are powered up. Once powered, the staus light will illuminate (see page 3 for LED Status Indicators). Network System Status stem Stat Power Reset Plug user key into the USB port on the top of the Hub. When the key LED lights green, it has been added to the system whitelist. Remove and repeat for all other user keys. Plug in any user key in for 10 seconds. After 10 seconds, the Hub status indicator will flash blue, indicating the Hub is in network provisioning mode. Network System Status tattatm Stataatuaa Power Reset Remove the key (blue LED will stay flashing on Hub for up to 15 minutes). Take any of the user keys to each position that has a flashing yellow LED and plug in the key for 10 seconds (the key LED will light up red). After 10 seconds, the puck LED will flash blue until it connects to the Hubs network. Network System Status tattatm Stataatuaa Power Reset After connecting to the network, the LED on the puck will double white flash every 5 seconds, the keys LED will still remain red. Remove and re-insert the key;
the keys LED should light green, indicating the key will now control the puck. Removing the key after the LED illuminates green will arm the position if the position is fully merchandised. MTI P/N 063-00210 rev D 2019 MTI All Rights Reserved 2 CONNECT HUB PRODUCT MANUALwww.mtigs.com | T:800.426.6844147258369 LED STATUS INDICATORS Visual Reference System Status Condition Network System Status Power Reset Network System Status stem Stat Power Reset Network System Status stem Stat Power Reset Network System Status stem Stat Power Reset No Lights On Hub has no power and backup battery has been depleted. Reconnect Hub to power. Status LED Solid Green Hub is fully functional:
Mesh network communication is good MTI Connect cloud communication is good Status LED Flashing Blue Hub is in mesh provisioning mode. Status LED Solid Yellow No mesh communication - provision Pucks/
Locks or move Hub closer to them. Status LED Solid Red MTI Connect cloud communication error. If this condition persists for more than 5 minutes, cycle power to the hub. If the condition continues, call for support. Status LED Flashing Red Hub is in battery backup - connect to power. MTI P/N 063-00210 rev D 2019 MTI All Rights Reserved 3 CONNECT HUB PRODUCT MANUALwww.mtigs.com | T:800.426.6844 CONNECTIONS 1. 2. 3. 4. 5. 6. 7. 8. 1. Auxiliary Micro USB Power Port - Used for installation and maintenance 2. HDMI Port - Used for installation and maintenance 3. Audio/Video 3.5mm Port - Used for installation and maintenance 4. Primary Power Port - The standard power input. Connect a 5V power supply, rated for 10 watts or more 5. Dipswitches - Sets configurations at installation. Refer to dipswitch setting table in appendix. 6. Reset button - Used to reset the list of whitelisted IntelliKeys 7. Ethernet port - Connect an Ethernet (RJ45) cable from a router or a broadband modem for network or Internet access. The two lights next to the connector indicate the connectivity status and network activity. 8. USB ports - Used for installation and maintenance Warning: Ports designated as used for installation and maintenance must not be accessed by end users. Only MTI-certified technical personnel may use these ports during installation and maintenance. MTI P/N 063-00210 rev D 2019 MTI All Rights Reserved 4 CONNECT HUB PRODUCT MANUALwww.mtigs.com | T:800.426.6844 FCC AND ISED STATEMENT FCC ID: 2AA2X-16500361 Model: Connect Hub FCC Statement This device complies with Part 15 of the FCC Rules. Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the users authority to operate the equipment. The RF Exposure Compliance distance is 20 millimeters. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ISED Certification Number: 24439-16500361 Model: Connect Hub ISED Statement This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. CAN ICES-3(B)/NMB-3(B) Le prsent appareil est conforme aux CNR Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) il ne doit pas produire de brouillage et (2) l utilisateur du dispositif doit tre prt accepter tout brouillage radiolectrique reu, mme si ce brouillage est susceptible de compromettre le fomctionnement du dispositif. CAN ICES-3(B)/NMB-3(B) The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre lexemption des limites courantes dvaluation dans la section 2.5 de RSS 102 et la conformit lexposition de RSS-102 rf, utilisateurs peut obtenir linformation canadienne sur lexposition et la conformit de rf. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 millimeters between the radiator and your body. Cet metteur ne doit pas tre Co-plac ou ne fonctionnant en mme temps quaucune autre antenne ou metteur. Cet quipement devrait tre install et actionn avec une distance minimum de 20 millimtres entre le radiateur et votre corps. Technical Data Operating Frequency:
Operating Temperature:
Max Power:
2405- 2480MHz 0 C to 40 C 2.4GHz < 20 dBm MTI P/N 063-00210 rev D 2019 MTI All Rights Reserved 5 CONNECT HUB PRODUCT MANUALwww.mtigs.com | T:800.426.6844