User manual | Users Manual | 1.93 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 |
|
External photographs | External Photos | 1018.35 KiB | ||||
1 |
|
Internal photographs | Internal Photos | 1.14 MiB | ||||
1 |
|
Label / label location | ID Label/Location Info | 230.91 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | RF Exposure Info | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | User manual | Users Manual | 1.93 MiB |
MCU-30 User Manual Mobilicom LTD Hametzoda 31, Azor -Israel Phone : +972-77-7103060 - Fax : +972-77-7103060 - www.mobilicom.com MCU-30 User Manual This manual contains information that is proprietary of Mobilicom Ltd. Notice No part of this publication may be reproduced in any form whatsoever without prior written approval by Mobilicom. License Terms Mobilicom hereby grants a non-exclusive, nontransferable worldwide license to the licensee of this software product to use and install Mobilicom's MC-EMA software, in object code only for the sole and internal purpose of configuring, monitoring and managing Mobilicom's MCUs. Warranty Mobilicom does not warrant that this software product is free from errors and/or will run properly on all computer hardware and/or operating systems. Mobilicom does not warrant that this software will operate in the combinations which may be selected for use by end users or that the operation of this software product will be uninterrupted or error free. Limitation of Liability Mobilicoms cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this agreement and the MC-EMA shall not exceed the sum paid to Mobilicom for the purchase of the MC-EMA. In no event shall Mobilicom be liable for any indirect, incidental, consequential, special or exemplary damages or lost profits, even if Mobilicom has been advised of the possibility of such damages. This agreement shall be construed and governed in accordance with the laws of the State of Israel. Page : 2 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd Document Information MCU-30 User Manual Date Version Author(s) 06.05.13 19.12.13 17.2.14 4.6.14 21.10.14 12.01.15 2.04.15 27.08.15 14.06.16 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Tomer Hot Tomer Hot Tomer Hot Tomer Hot Tomer Hot Tomer Hot Tomer Hot Tomer Hot Tomer Hot 28.08.17 1.8.1 Tomer Hot 28.01.18 1.8.2 Boaz Pick 29-1-2018 1.8.3 Boaz Pick 14-2-2018 1.8.4 Boaz Pick Reference Distribution External Comments Release External LED functionality External Added PTMP External Configuration changes External Updates External Update of product images External Added Collaborative MESH External Datasheet updates External Added Embedded unit phase 1 External Added FCC Statement External Changes for FCC External Change per FCC Request External Section 6.1.2 , Antenna type +Declaration of Conformity Section Revision History Change Revision All Section 10 Appendix A Updated Datasheet Changed Images Added Section 4.2, 5 and Appendixes A,B,C Sections 6.1.3, 13 and 15.1 Added Embedded info/drawings Added FCC Statement Removed confidential statement Typos fixing Remove Optional statements 6.1.2, 13, p51 Antenna Type Dipole 1.5 1.6 1.7 1.8 1.8.1 1.8.2 1.8.3 1.8.4 Page : 3 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Contents 1 QUICK START GUIDE ........................................................................................ 8 2 INTRODUCTION ................................................................................................. 9 2.1 ABBREVIATION LIST ......................................................................................... 9 3 OVERVIEW ....................................................................................................... 12 3.1 NETWORK TOPOLOGIES AND APPLICATIONS .................................................... 13 3.1.1 Mobile Point-to-Point (PTP)................................................................. 13 3.1.2 Mobile MESH - Multi-Point-to-Multi-Point (MPTMP) ............................ 13 3.1.3 Collaborative MESH Collaborative Relay ......................................... 13 3.2 MCU-30 MAIN FEATURES ............................................................................. 14 3.3 PACKETS SUPPORTED BY THE MOBILICOM NETWORK ....................................... 14 4 PHYSICAL DESCRIPTION ............................................................................... 15 4.1 FRONT VIEW CONNECTORS ........................................................................... 15 4.2 REAR VIEW CONNECTORS ............................................................................. 16 5 MECHANICAL SPECIFICATIONS ................................................................... 19 6 TECHNICAL SPECIFICATIONS ....................................................................... 19 6.1 RADIO AND MODEM SPECIFICATIONS .............................................................. 19 6.1.1 Frequency bands available with the MCU-30: ..................................... 19 6.1.2 Antennas ............................................................................................. 19 6.1.3 RF Characteristics ............................................................................... 20 6.2 6.3 6.4 POWER SPECIFICATIONS ............................................................................... 21 ENVIRONMENTAL SPECIFICATIONS ................................................................. 21 EMBEDDED GPS CHARACTERISTICS .............................................................. 22 7 TDMA ................................................................................................................ 23 8 MOBILE PTP (POINT-TO-POINT) .................................................................... 23 8.1 MOBILE PTP LINK STEP-BY-STEP CONFIGURATION ......................................... 24 8.2 MCU-30 LED INDICATOR .............................................................................. 25 9 MOBILE MESH (MULTI-POINT-TO- MULTI-POINT) NETWORK .................... 26 9.1 MOBILE MESH NETWORK STEP-BY-STEP CONFIGURATION ............................. 28 9.2 MCU-30 LED INDICATOR .............................................................................. 30 10 COLLABORATIVE MESH (COLLABORATIVE RELAY) .......................... 31 10.1 COLLABORATIVE MESH NETWORK EXAMPLE:................................................. 32 10.2 CONFIGURING A COLLABORATIVE MESH NETWORK ........................................ 34 10.3 MCU-30 LED INDICATOR .............................................................................. 36 Page : 4 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 11 12 INTRODUCTION TO PTMP (POINT-TO- MULTI-POINT) ............................. 37 INSTALLATION AND SETUP ....................................................................... 38 12.1 PACKAGE CONTENTS .................................................................................... 38 12.2 CONNECTING THE ANTENNAS ........................................................................ 38 12.3 CONNECTING THE POWER ............................................................................. 38 13 14 APPENDIX A - DATA SHEET ....................................................................... 39 APPENDIX B - MECHANICAL DRAWINGS ................................................. 41 14.1 MCU-30 RUGGED DRAWINGS ....................................................................... 41 14.2 MCU-30 EMBEDDED DRAWINGS .................................................................... 42 15 APPENDIX C CONNECTORS PINOUT .................................................... 43 15.1 MAIN (DATA) CABLE .................................................................................... 43 15.2 POWER CABLE ............................................................................................. 44 15.3 EMBEDDED SYSTEM DATA CONNECTOR .......................................................... 45 15.4 EMBEDDED SYSTEM POWER CONNECTOR ....................................................... 46 16 APPENDIX D TROUBLESHOOTING .......................................................... 47 Page : 5 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual List of Figures Figure 1: MCU-30 ..................................................................................................... 12 Figure 2: Asymmetric link configuration .................................................................... 13 Figure 3: MCU-30 Front View ................................................................................... 15 Figure 4: MCU-30 Embedded Front View ................................................................. 15 Figure 5: MCU-30 Rear View .................................................................................... 17 Figure 6: MCU-30 Embedded Rear View ................................................................. 18 Figure 7: shows the transmit frames of VC and Node from Power Up ..................... 23 Figure 8: MC-EMA-PTP connect to screen............................................................... 24 Figure 9: MC-EMA-PTP Configuration screen .......................................................... 25 Figure 10: Transmit frames of MCUs in Mobile MESH from Power Up .................... 27 Figure 11: Simple air transmission vector ................................................................. 27 Figure 12: MC-EMA-MPTMP connect to screen ....................................................... 28 Figure 13: MC-EMA-MPTMP configuration validation .............................................. 29 Figure 14: MC-EMA-MPTMP Network configuration screen..................................... 29 Figure 15: Collaborative MESH ............................................................................... 32 Figure 16: C.MESH network transmission in a 3 units network which all units are relayed ................................................................................................................ 33 Figure 17: C.MESH network transmission in a 3 units network unit 2 is relay only .. 33 Figure 18: MC-EMA-MPTMP connect to screen ....................................................... 35 Figure 19: MC-EMA-MPTMP configuration validation .............................................. 35 Figure 20: MC-EMA-MPTMP network configuration screen ..................................... 36 Figure 21: MAIN Connector Front View (MCU-30 side) ............................................ 43 Figure 22: PWR Connector Front View (MCU-30 side) ............................................ 44 Figure 23: Embedded System Data Connector (MCU-30 side) ................................ 45 Figure 24: Embedded System Power Connector (MCU-30 side) ............................. 46 Page : 6 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual List of Tables Table 1: Abbreviation List......................................................................................... 11 Table 2: MCU-30 Mechanical Specifications............................................................ 19 Table 3: MCU-30 Power Specifications ................................................................... 21 Table 4: MCU-30 Environmental Specifications ....................................................... 21 Table 5: Embedded GPS Characteristics of the MCU-30 ........................................ 22 Table 6: MAIN Connector Type and Pin Mapping (connectors on cable side) ......... 43 Table 7: PWR Connector Type and Pin Mapping .................................................... 44 Table 8: Embedded System Data Connector Pin Mapping ...................................... 45 Table 9: Embedded System Power Connector Pin Mapping ................................... 46 Page : 7 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 1 Quick Start Guide MCU-30 User Manual If you are familiar with Mobilicom's MCUs, use this guide to prepare for operation. If you are not familiar with the Mobilicom MCUs, it is recommended to read the entire user guide. You can also visit the Mobilicom website for more material and videos at http://www.mobilicom.com Before turning the MCU on:
1. Connect antennas to the MCU RF1 and RF2 connectors. 2. Connect the GPS antenna to the AUX connector (For a Mobile MESH and Collaborative MESH links it is mandatory to connect the GPS antenna). 3. Connect the data cable to the MAIN connector. 4. Connect the power cable. 5. Connect a DC power source to the power cable according to the specification. 6. If the MCUs are pre-configured, they will start operating automatically (plug and play). 5. Otherwise: connect an Ethernet cable between the data cable and the PCs Ethernet adapter. 7. Use the MC-EMA to configure the unit. CAUTION Powering up an MCU unit without connecting the antennas can cause unrepairable damage to the MCU-30. Page : 8 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 2 Introduction MCU-30 User Manual As a leading global mission-critical-communications solution provider, Mobilicom develops and delivers Bound-Free Mobile Private Network technology and solutions for wireless mobile networks, without the need for any infrastructure. By leveraging 4G technology combined with Mobile MESH network topology, Mobilicom assures optimal secured wireless communications. All our products and solutions are designed to operate as a unified entity on a single platform, regardless of which unit is operating. With versatile network topologies and large product portfolio, Mobilicom caters to every deployment and project scope from small to large scale with the highest flexibility, reliability and mobility in the market. 2.1 Abbreviation List BPS BW CEP Bits Per Second Bandwidth Circular Error Probable (Accuracy) CINR Carrier to Interference and Noise Ratio (Signal to Noise Ratio) CPLD Complex programmable logic device CRC dB dBm CDD CTC DC Cyclic Redundancy Code Decibel Power ratio in decibels of the measured power referenced to one milliwatt Cyclic Delay Diversity Convolutional Turbo Code Direct Current EMA Element Management Application EMI ETH ETSI FAE FCC FEC FFT Electromagnetic Interference Ethernet European Telecommunication Standard Institute Field Application Engineer Federal Communication Commission Forward Error Correction Fast Fourier Transform Freq. Frequency Page : 9 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual FW GHz Firmware Gigahertz GPS Global Positioning System HD HPA HW ID IP LAN LAT LED LON LOS mW High Definition (Video) High Power Amplifier Hardware Identification (Number) Internet Protocol Local Area Network Latitude Light Emitting Diode Longitude Line Of Sight Milli Watt MBR Multi Band Radio MCU Mobilicom Communications Unit MHz Mega Hertz MIMO Multiple In Multiple Out MRC Maximal Ratio Combining MPTMP Multi-Point To Multi-Point Node N.C OEM Mobilicom Communications Unit, In PTP setup act as end point communication unit Not Connected Original Equipment Manufacturer OFDM Orthogonal Frequency Division Modulation OS PC PPS PTP QAM Operating System Personal Computer Pulse Per Second Point To Point Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying (modulation) RF Radio Frequency RMS Root Mean Square (Average) Page : 10 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual RSSI Receiver Signal Strength Indication RX Receive SBAS Satellite Based Augmentation System SW TDD Software Time Division Duplexing TDMA Time Division Multiple Access TX UAV UGV VC Transmit Unmanned Aerial Vehicle Unmanned Ground Vehicle Virtual Concentrator, Mobilicom Communications Unit in PTP setup act as end point communications unit that distribute clocks in the system VLAN Virtual LAN VPN Virtual Private Network Table 1: Abbreviation List Page : 11 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 3 Overview MCU-30 User Manual Mobilicom's multifunctional MCU-30 unit is a 4G Technology combined with Mobile MESH (not a cellular device), IP communications unit that delivers ad-hoc direct wireless mobile communication including HD Video, data and VoIP without the need for any infrastructure. Figure 1: MCU-30 Communications between MCU units is both robust and broadband quality, of several Mbps transmission between units. Ideal for large area coverage, including non-line-of-sight (N-LOS), conditions in rural and urban areas, with extended range provided by a powerful relay capability. Its compact size makes this device suitable for public transportation, utility grids, emergency/security vehicles as well as helicopters / UAV / UGV usage. The MCU-30 is part of Mobilicoms Mobile Communications Unit (MCU) product line which also includes the MCU-200, a high-end, high performance product optimized for various land, air and sea platforms. MC-HPA, is a High-Power Amplifier that enables extended range when required and MC-EMA, MCU management software. Page : 12 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 3.1 Network Topologies and Applications 3.1.1 Mobile Point-to-Point (PTP) A mobile point-to-point system includes 2 units, while the bandwidth ratio between the two MCU units is configurable according to the application. It can be symmetric when a full duplex communication is required (50% to each unit) or asymmetric up to 10% to one unit (VC or node) and 90% to the other unit (i.e. Helicopter which transmits video to the ground unit and its camera is controlled by it). Example for asymmetric link: 8.4Mb/s configuration, where 10% of available BW is allocated for uplink and 90% is allocated for downlink Figure 2: Asymmetric link configuration 3.1.2 Mobile MESH - Multi-Point-to-Multi-Point (MPTMP) A multi-point-to-multi-point network is a cluster of MCUs over a radio link. The cluster includes at least 2 MCU units and can run up to 32 MCUs. Each MCU unit receives from, and transmits to, all other members of the cluster within a reception range. 3.1.3 Collaborative MESH Collaborative Relay The Mobilicom Collaborative MESH technology is an enhancement to the Mobile MESH capabilities. The Collaborative MESH allows to choose the data, which is received by all cluster members simultaneously, to be relayed by any of the cluster members (i.e. multiple MCUs can relay the data transmitted from a specific unit at the same time). This feature significantly extends the network's range and reliability, without any implication on its capacity (compared to a simple relay system). Page : 13 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 3.2 MCU-30 Main Features MCU-30 User Manual Diversity support MIMO antenna processing technologies. Scalable solution from a Mobile Point-to-Point to a MPTMP MESH High mobility with continuous transmissions up to 800km/h Mobile broadband network Small physical dimensions (portable device) Low power consumption (less than 10W) Plug-and-play installation Battery operated Dual power feed for hot swap during operation 3.3 Packets supported by the Mobilicom network The MCU physical link supports Ethernet (IEEE 802.3) which includes:
1. Ethernet, VLAN Services, VPN and any other Protocol over IP. 2. Including real time applications using RT Protocols such as: Voice, Video, Data 3. Broadcast, Multicast, Unicast Any Ethernet packet received by the MCUs Ethernet port, is encapsulated with Mobilicoms standard frame for transmitting over the air-link to the remote MCU. The remote MCU recovers the original Ethernet packet and forwards it to the Ethernet port. NOTE The MCU is similar to Ethernet layer 1 (physical layer) which makes the integration with your equipment to be nothing more than connecting the ETH cable. Page : 14 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 4 Physical Description 4.1 Front View Connectors RF1: Antenna 1 Connector, SMA/F 50 Ohm RF2: Antenna 2 Connector, SMA/F 50 Ohm AUX: GPS Antenna Connector, SMA (Female) Figure 3: MCU-30 Front View Figure 4: MCU-30 Embedded Front View Page : 15 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 4.2 Rear View Connectors Main:
MCU-30 User Manual MCU-30: A HR22-12WTRA-20P connector is used. MCU-30 Embedded: A Molex P/N: 5015715007 connector is used. The data connectors include 10/100Mbps ETHERNET port and can in additional support Serial RS-232 port. Power:
MCU-30: A LF10WBRB-4P connector is used. MCU-30 Embedded: A Molex P/N: 5023520600 connector is used. The power connecters utilizing 7-14.5VDC. The connector includes Dual Inputs for Hot Swap during operation. CAUTION Connecting two batteries in parallel for a long period might cause common discharge. For hot swap connect the second battery and disconnect the first one after. CAUTION When an MCU-30 is carried by a personnel, environment temperature should not exceed 45C (113F) NOTE Information about the connectors pin assignment is available in Appendix C Connectors Pinout LED: The MCU-30 LED indicates power up and link status Page : 16 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 5: MCU-30 Rear View Page : 17 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 6: MCU-30 Embedded Rear View Page : 18 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 5 Mechanical Specifications MCU-30 User Manual The MCU-30 has various packaging options enabling a wide range of applications and installation scenarios. The most common packaging option is the outdoor unit with rugged casing, designed for harsh environment conditions and flight ready. An extended ruggedized environmental casing should be used for extreme environmental conditions and is available for ordering. There is an option for an embedded package (electronic boards only) which does not include any casing. It is commonly used for embedding the unit as OEM into systems such as UAVs, robots and other applications. In such cases, the customer/partner is responsible for the mechanical casing and mechanical design considerations such as cooling, (heat sink), sealing etc. The following table shows the MCU-30 mechanical details for various packages types. Dimensions
[HxWxD] cm
[HxWxD] inch Weight (g) Weight (Oz) Embedded Package 7.4 x 8.0 x 2.7 cm 2.9 x 3.15 x 1.1 140 gr. Ruggedized 12 x 9 x 6 cm 4.7 x 3.5 x 2.3 Extended Rugged 12 x 9 x 6 cm 4.7 x 3.5 x 2.3 550 gr. 550 gr. 4.94 oz. 19.5 oz. 19.5 oz. Table 2: MCU-30 Mechanical Specifications 6 Technical Specifications 6.1 Radio and Modem Specifications 6.1.1 Frequency bands available with the MCU-30:
700-950MHz 2.3-2.7GHz 2.4GHz unlicensed band 4.9-5.9GHz (including all the unlicensed bands). Additionally, there is an option for a multiband radio including 2 different bands within the same MCU unit. The MCU-30 family is hardware ready to support any frequency between 70MHz and 6GHz upon specific demand submitted by the customer. 6.1.2 Antennas Various standard antennas Dipole, 2dBi maximum gain, Omni with SMA/M connector can be supported. Page : 19 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 6.1.3 RF Characteristics MCU-30 User Manual Max output power: 2 x 0.5W per channel Average output power :2x 200mW per channel (23dBm) Noise Figure: 5dBm Transmission Power Control Range: 50dB in 1dB steps. Radio Access Method: OFDM - TDMA Configuration & Diversity Support: 2X2 MIMO with MRC(RX) and CDD(TX) Frequency Resolution: 0.25MHz Channel bandwidth: Configurable 4.2/8.4MHz FFT Supported: 512 Guard band: 64 sub-carries each side Total subcarriers used per symbol: 384 Data carriers used: 336 Pilot carriers used: 48 Sub carrier spacing: 13KHz for 5MHz bandwidth with 5msec frame Modulations: QPSK FEC methods: CTC FEC Ratios , , Error Detection: CRC32 Full TDD asymmetrical duplexing Flexible ratio from 1:1 to 1:9 in Mobile PTP Resolution of 1% between all units in Mobile MESH and Collaborative MESH networks NOTE The wide configurable power control range enables transmitting in low TX power when not needed and by that reducing the power consumption. Page : 20 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 6.2 Power Specifications MCU-30 User Manual The MCU-30 is designed to be battery operated (DC) with low power consumption. Its design allows for multiple battery cell configurations (different voltages). Power - LF10WBRB-4P DC Voltage (Battery Operated) 7-14.5VDC Dual Inputs Hot swap during operation Power Consumption 8 Watts average use Up to 12 Watt Depends on the operational scenario (TX:RX Ratio) Table 3: MCU-30 Power Specifications 6.3 Environmental Specifications The MCU-30 is designed to meet international EMI, Radio & Environmental Standards, such as wireless ETSI & FCC etc. Environmental Temperature Range Ruggedized Extended Rugged Embedded Humidity Sealing Operating
-20C to 50C
-20C to 60C N/A Storage
-50C to 85C
-50C to 85C
-50C to 85C 5 to 95%
Outdoor, rain proof Table 4: MCU-30 Environmental Specifications Page : 21 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 6.4 Embedded GPS Characteristics The MCU-30 has a built in GPS receiver. In a Mobile PTP network configuration it is used for location information only (which can be operated by the customer via the Mobilicom API). In a Mobile MESH and Collaborative MESH configuration it is used for synchronization and can also be used by the customer for location purposes. The MCU-30 can use both active and passive GPS antennas. The power for the active antenna is provided by the MCU via a regular GPS SMA connector. Item Description Receiver Type GPS L1 C/A code Accuracy Position 2.5 m CEP SBAS 2.0 m CEP Acquisition Cold start: 27 s Aided start: < 3 s Hot start: 1 s Sensitivity Tracking: 161 dBm Cold start: 147 dBm Hot start: 156 dBm Timing Accuracy RMS 30 ns 99% < 60 ns Granularity 21 ns Table 5: Embedded GPS Characteristics of the MCU-30 Page : 22 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 7 TDMA MCU-30 User Manual Time division multiple access (TDMA) is a channel access method for shared medium networks. It allows several MCUs to share the same frequency channel by dividing the signal into different time slots. The MCUs transmit and receive on the same frequency in a synchronized manner. Every MCU transmits in its own dedicated time slots. On the other time slots it receives the transmission sent by the other units which are members of the same network (which are also transmitting on their own dedicated slots). TDMA require synchronization system. The system is synchronized internally, externally or via GPS (synchronization varies between topologies and method used). The MCU uses TDMA regardless of the application type, Mobile PTP, Mobile MESH or Collaborative MESH. 8 Mobile PTP (Point-to-Point) A Mobile PTP network is a radio link between 2 MCUs. The configuration (frequency and profile) of both units must be the same with only one difference, one MCU is configured as a VC (Virtual Concentrator) while the other unit is configured as a Node. The VC works with its internal clock and synchronizes the Node. After power-up the VC starts transmitting regardless of link status. The node however, does not transmit and stays in RX mode, it tries to acquire synchronization by finding a preamble
(synchronization pattern). As soon as the node recognizes the pattern, it starts to transmit according to its allocated time slot. The transmission bandwidth ratio is pre-defined as part of the profile configuration. It can be symmetric when full duplex communications is required (50% to each unit) or asymmetric up to 10% to one unit (VC or node) and 90% to the other unit. Figure 7: shows the transmit frames of VC and Node from Power Up Page : 23 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 8.1 Mobile PTP Link Step-by-Step Configuration In order to build a Mobile PTP link, 2 MCUs are required. One MCU acts as a VC, while the other as a Node. 1. Connect antennas to RF1 and RF2 connectors, and power up the MCU. CAUTION Powering up an MCU unit without connecting the antennas can cause unrepairable damage to it. 2. Connect the MCU to a PC using a standard Ethernet Cat 5 cable. 3. Set static IP in the 192.168.131.xxx subnet. (for more information see MC-
EMA P2P User Manual). 4. Using the MC-EMA: connect to the MCU (VC or Node, by default. The MCUs are shipped with a Mobile PTP SW and are set as a VC). From the MC-EMA, connect to screen choose the unit and click on the Connect button. Figure 8: MC-EMA-PTP connect to screen 5. From the MC-EMA main menu (on the left side) choose the configuration screen and set the MCU to VC (if needed) by choosing the VC radio button than click on the Set Mode button the unit will reboot 6. Change the frequency to the required frequency and click on the Set Frequency button the unit will reboot 7. Set the profile as required (RF bandwidth, bitrate and ratio) click on the Set button - the unit will reboot 8. Repeat stages 1-4 with the 2nd unit. 9. Go to configuration screen and set the MCU to Node (if needed) the unit will reboot. 10. Repeat stages 6-7 with the 2nd unit. Page : 24 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 9: MC-EMA-PTP Configuration screen NOTE A Mobile PTP requires 2 MCUs configured with same Frequency. and Profile. 8.2 MCU-30 LED indicator By following the LED on the MCU the power and link status can be monitored, it is described as follows:
LED is ON the unit is on, air link is down and no data is transmitted. LED blinks slowly Air link is up but there is no data over the link LED blinks fast Air link is up and data is transferred over the air link Link status, CINR, RSSI, throughput and unit log information is available using the MC-EMA. Page : 25 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 9 Mobile MESH (Multi-Point-to- Multi-Point) Network A Mobile MESH network is a cluster of MCUs over a radio link. The cluster includes at least 2 MCU units and can range up to 32 MCUs. Each MCU unit receives from, and transmits to, all other members of the cluster within the reception range. The system is synchronized using a GPS or 1PPS External source. The MCU has an internal GPS receiver and an external connector for GPS antenna (passive or active). In the Mobile MESH network, the transmission bandwidth is pre-allocated to each member of the cluster; this allocation is called a transmission vector and can be configured using the MC-EMA. All MCUs in the cluster must have the same configuration (Frequency, Profile and Transmission Vector) with only one difference, unit ID number. An MCU can be a listener only, receiving the information from all other members of the cluster without consuming any bandwidth by not In such configuration the listener unit cannot be monitored via other units (over the air), it cannot be seen in the link monitor screen since it does not transmit at any time. This application can be used when transmitting broadcast data to several units, when there is no need for sending data to the other direction. It can also be used when a unit is needed as a relay only unit. transmitting. After powering up the MCU, it waits for synchronization (1PPS). As soon as the MCU is synchronized (regardless of other units synchronization) it starts to transmit in its dedicated time slot(s). NOTE The MCU can be synchronized by an external 1PPS source. For further information on this option, contact: support@mobilicom.com. Page : 26 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 10: Transmit frames of MCUs in Mobile MESH from Power Up Figure 11: Simple air transmission vector Page : 27 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 9.1 Mobile MESH Network Step-by-Step Configuration 1. Connect antennas to RF1 and RF2 connectors, and power up the MCU. CAUTION Powering up an MCU unit without connecting the antennas can cause unrepairable damage to it. 2. Connect the MCU to your PC using Ethernet cable. 3. Set static IP in the 192.168.131.xxx subnet. (for more information see MC-
EMA MPTMP User Manual). 4. Using the MC-EMA (MPTMP Version) connect to the MCU by clicking the button of the unit ID (by default MPTMP configuration the unit ID is set to 1) Figure 12: MC-EMA-MPTMP connect to screen Page : 28 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 5. From the MC-EMA main menu (left side of the screen) go to network configuration screen and configure:
a. Network Frequency b. TX Power c. Transmission Vector (bandwidth allocation) d. Profile 6. Click 'Verify' and chose the unit ID from the dropdown list. Figure 13: MC-EMA-MPTMP configuration validation 7. Click configure unit the configuration is now downloaded to the MCU. 8. The MCU reboots with the new configuration and unit ID number. 9. Repeat stages 1-10 with other units in the network. Figure 14: MC-EMA-MPTMP Network configuration screen Page : 29 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual NOTE Verify that each unit has a different unit ID NOTE In a Mobile MESH network configuration, the Number of Hops and Max retransmit parameters should be set to 1. NOTE unlimited amount of MCUs can use the same unit ID when in listener only mode. NOTE A Mobile MESH network requires at least 2 MCUs configured with same Transmission Vector, Frequency and Profile. 9.2 MCU-30 LED indicator By following the LED on the MCU the power and link status can be monitored, it is described as follows:
LED is ON the unit is on, air link is down and no data is transmitted. LED blinks slowly 1 PPS signal is locked but there is no data over the link LED blinks fast Air link is up and data is transferred over the air link Link status, CINR, RSSI, Throughput and unit Log are available using the MC-EMA. Page : 30 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 10 Collaborative MESH (Collaborative Relay) In telecommunications, a relay/repeater is an electronic device that receives a signal and retransmits it at a higher level or higher power, or onto the other side of an obstruction, so that the signal can cover longer distances. Unlike the description above, Mobilicoms Collaborative MESH does not require special hardware. In a Mobilicom Collaborative MESH network that is based on the Mobilicoms Mobile MESH network, the user needs only to choose the MCU whose data needs to be relayed (can be one MCU or the entire cluster), and any member of the cluster (even listener only units) that are within the reception range repeat it on a dedicated time slots. By that, the network achieves better relay capabilities although the MCUs locations may changes randomly. The data can be relayed up to 4 times (4 hops). It can be relayed by the originating MCU or any other MCU that has already received the data in the previous relay slots. As a result the link is more robust and can reach longer distances. As in the Mobile MESH network, the air time is divided into time slots. Each unit has its own slots in which it transmits data. Every unit which is defined as a relayed unit, gets specific dedicated relay slots to it. These slots are taken from the allocated bandwidth of the relayed unit. For this reason, only the relayed unit has lost from its allocated bandwidth for the relay transmission. The other units bandwidth is not affected this way. The actual bandwidth of an MCU that is marked as a relayed unit is the allocated bandwidth (in the Transmission Vector configuration) divided by the Number of Hops. A Hop represents one portion of the path between source and destination. We can say that any members of the cluster within a reception range of the current transmitting MCU is one Hop from this MCU. Other members of the cluster within the reception range of these MCUs is in 2 Hops from the original MCU and any cluster member that in the reception range of these units is in 3 Hops from the original MCU and so on. As a Mobile MESH network, the system is synchronized using a GPS or external 1PPS source. The configuration is the same as in the Mobile MESH network where All MCUs in the cluster must have the same configuration (Frequency, Profile and Transmission Vector) with only one difference - unit ID number. Additional configuration which is specific to the Collaborative MESH network is the Number of Hops, Max retransmission and enabled relay check box per node in the cluster. After powering up the MCU, the unit waits for synchronization. As soon as the MCU is synchronized (regardless to other units synchronization) it starts to transmit on its dedicated time slot(s). Page : 31 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 10.1 Collaborative MESH Network Example:
1. Units 2 and 3 are within the reception range of unit 1. 2. Units 4 and 5 are within the reception range of unit 3. 3. We configure unit 1 as a unit that needs to be relayed. 4. When unit 1 transmits its data, it is received by units 2 and 3. Units 1, 2 and 3 retransmit the same data, as unit 1 transmitted in the previous slot at the same time (achieved by the fact that it is a synchronized network) this time the data is received by units 4 and 5. Figure 15: Collaborative MESH Page : 32 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 16: C.MESH network transmission in a 3 units network which all units are relayed Figure 17: C.MESH network transmission in a 3 units network unit 2 is relay only Page : 33 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 10.2 Configuring a Collaborative MESH Network 1. Connect antennas to RF1 and RF2 connectors, and power up the MCU. CAUTION Powering up an MCU unit without connecting the antennas can cause unrepairable damage to it. 2. Connect the MCU to a PC using Ethernet cable. 3. Set static IP in the 192.168.131.xxx subnet. (for more information see MC-EMA MPTMP User Manual). 4. Using the MC-EMA (MPTMP Version): connect to the MCU by clicking the button of the unit ID (by default, the unit ID is set to 1) Page : 34 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 18: MC-EMA-MPTMP connect to screen 5. From the MC-EMA main menu (left side of the screen) go to network configuration screen and configure:
a. Network Frequency b. TX Power c. Number of Hops and Max Retransmission (should be equal) d. Transmission Vector (bandwidth allocation) e. Profile 6. Click Verify and chose the unit ID from the dropdown list. Figure 19: MC-EMA-MPTMP configuration validation 7. Click configure unit the configuration is now downloaded to the MCU. 8. The MCU reboots with the new configuration and unit ID number. 9. Repeat stages 1-10 with the other units in the network. Page : 35 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Figure 20: MC-EMA-MPTMP network configuration screen NOTE Verify that each unit has a different unit ID NOTE unlimited amount of MCUs can use the same unit ID when in listener only mode. NOTE A Collaborative MESH network requires at least 3 MCUs configured with the same transmission vector (including relayed units), Frequency and Profile. 10.3 MCU-30 LED indicator The Led Indications are the same as in the Mobile MESH section ( 9.2). Page : 36 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 11 Introduction to PTMP (Point-to- Multi-Point) A PTMP network is a unique topology; it can be achieved by Mobile MESH networks. It is widely used for multicast/broadcast data distribution from a main unit to many stations. In this case only one of the stations is controlling the main unit (bi-directional link) while the other units are only receiving the data. In this network, there is one MCU which is set to be unit ID 1, this unit is the data distributer, unit with the unit ID 2 is the controller. In this network there are many listener units which are defined by different unit IDs. The transmission vector includes 3 units when the 3rd unit members bandwidth allocation is set to 0. In cases where a handoff of the controller position is needed (between other
"listener" members), the transmission vector will be set to 2 units. All the listener units will be configured with unit ID 2 as well. The TX power of unit 1 and 2
(controller) should be set to maximum (23dBm) and the other listener units TX power should be set to minimum (-40dBm). The handoff procedure should be done in the following steps:
1. TX power of the current controller should be set to minimum (-40dBm) 2. TX power of the new controller should be set to maximum (23dBm) NOTE listener MCU cannot be monitored over the air and isnt present in link monitor. Page : 37 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 12 Installation and Setup 12.1 Package Contents MCU-30 2 Detachable Antennas 12.2 Connecting the Antennas Antennas installation vary in size, shape, requirements and mounting method. The antennas should be as close to the MCU-30 as possible and can be connected to it directly. Recommended distance between antennas is ~1.5m (for 2.XGHz). Cables should be chosen according to their attenuation (lower attenuation gives better results) and flexibility (according to the path they pass through). Each cable should have SMA Male connector on the MCU end, and a connector matching to the antennas connector on the other. Recommended cable standards can be supplied by Mobilicom. 12.3 Connecting the Power The MCU-30 has a dual power feed enabling hot-swap battery replacement during operation. CAUTION Powering up an MCU unit without connecting the antennas can cause unrepairable damage to the MCU. Page : 38 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 13 Appendix A - Data Sheet Radio and Modem Frequency 700-950 MHz 902-928 MHz (ISM) 2.3-2.7GHz, 4.9-5.9 GHz, Multi Band Radio (MBR) Available Optional other frequencies in the range of 75MHz-6Ghz Antenna 2dBi , Dipole, SMA/M connector Antenna's Connectors 2 x SMA Female GPS Output Power (Average per channel) TX Power Control RX Dynamic Range Sensitivity Radio Access Method Duplexing Configuration Channel BW Frequency Resolution Diversity Support FFT Supported FEC method Modulations Throughput Synchronization Encryption*
*Upgrade Options Active and Passive 2x23dBm or 2x18dBm for 5GHz 50dB 70dB Max 101dBm OFDM - TDMA TDD Diversity support MIMO 2X2 4.2MHz/ 8.4MHz 0.25MHz TX & RX Diversity 512 32 2048 upon request CTC QPSK Up to : 8Mbps For P2P - Not required For Mobile MESH: GPS/ External 1PPS AES-128/256 Page : 39 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd Environmental Temperature Range Ruggedized Extended Rugged Embedded Humidity Interfaces Data MCU-30 User Manual Operating
-20C to 50C
-20C to 60C
-10C to 45C*
Storage
-50C to 85C
-50C to 85C
-50C to 85C 5 to 95%
Ethernet 10/100Mbps Full Ethernet Protocol Transparency IP,TCP,UDP, RTP, HTTP Optional Interfaces*
Dimensions Embedded Package Ruggedized Extended Rugged Weight Embedded Package Ruggedized Extended Rugged Power Broadcast, Multicast, Unicast Ethernet, VLAN, VPN RS232 /485 / 422GPIO, 1pps
[HxWxD] cm 7.4 x 8 x 2.7 cm 12 x 9 x 6 cm 12 x 9 x 6 cm Grams 140 gr. 550 gr. 550 gr.
[HxWxD] inch 2.9 x 3.15 x 1.1 4.7 x 3.5 x 2.3 4.7 x 3.5 x 2.3 Ounce 4.94 oz. 15.5 oz. 19.0 oz. DC Voltage (Battery Operated) 7-14.5VDC Power Consumption Up to12 Watt 8W Average Configuration and Management Unit Monitoring Application MC-EMA Network Management Application MC-NMA*
*Depends on the customers installation Page : 40 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 14 Appendix B - Mechanical Drawings 14.1 MCU-30 Rugged Drawings MCU-30 User Manual Page : 41 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 14.2 MCU-30 Embedded Drawings MCU-30 User Manual Page : 42 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 15 Appendix C Connectors Pinout 15.1 MAIN (Data) Cable MCU-30 User Manual Use a shielded CAT 5E (or higher) cable with 26 AWG gauge (or thicker) wires to connect the MAIN connector to a shielded RJ-45 connector (which then can be used for maintenance or plugged to an IP device as Camera and monitor). Follow the instructions provided in the connector's datasheets. Make sure the cables shield drain wire is properly connected to the shields of the connectors on both sides. The connector on the MCU side is: Hirose HR22-12WTRA-20P, on the cable side it is:
HR22-12TPD-20S (73) Figure 21: MAIN Connector Front View (MCU-30 side) MCU-30:
RJ45 Pin Name Description HR22-12TPD-20S(73) 1 2 3 4 1 2 3 6 Tx_D1+ Fast Ethernet 10/100 TPOP Transceiver Data +
R_D1-
Fast Ethernet 10/100 TPON Transceiver Data -
Rx_D2+ Fast Ethernet 10/100 TPIP Receive Data +
Rx_D2-
Fast Ethernet 10/100 TPIN Receive Data -
Table 6: MAIN Connector Type and Pin Mapping (connectors on cable side) Page : 43 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd 15.2 Power Cable MCU-30 User Manual Use a cable with 18 AWG gauge (or thicker) wires to connect the PWR connector to proper terminations that will connect to the DC source. Make sure the grounding pin is connected to a solid grounding point. The connector on the MCU side is: Hirose LF10WBRB-4P, On the Cable side it is: Hirose LF10WBP-4S. Figure 22: PWR Connector Front View (MCU-30 side) MCU-30 LF10WBP-4S Description 1 2 3 4 GND (-VDC) Vin1 (+VDC) Vin2 (+VDC) GND (-VDC ) Table 7: PWR Connector Type and Pin Mapping Page : 44 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 15.3 Embedded system Data Connector This connector is used for Ethernet, LED, RS232 connectivity to the unit. For the Ethernet connector use a shielded CAT 5E (or higher) cable with 26 AWG gauge (or thicker) wires to connect the data connector to a shielded RJ-45 connector. Follow the instructions provided in the connector's datasheets. Make sure the cables shield drain wire is properly connected to the shields of the connectors on both sides. The connector on the MCU side is: Molex P/N: 5015715007:
Figure 23: Embedded System Data Connector (MCU-30 side) MCU-30:
General Pins Name Description Molex P/N: 5015715007 1 2 30 3 5 15 17 35 37 39 41 GND GND External Led RS-232 (D9) 3 2 GND GND GND 0V GND 0V The Status LED indicates that the unit is powered on, and displays special status modes User Interface Input For GND (Pin 5 in the D9 connector ) use GND (pin 1 or 2) Output RS-232 (D9) Internal Use - Debug 3 2 Input For GND (Pin 5 in the D9 connector ) use GND (pin 1 or 2) Output RJ45 Pin Description 1 2 6 3 Tx_D1+ Fast Ethernet 10/100 TPOP Transceiver Data +
R_D1-
Fast Ethernet 10/100 TPON Transceiver Data -
Rx_D2-
Fast Ethernet 10/100 TPIN Receive Data -
Rx_D2+ Fast Ethernet 10/100 TPIP Receive Data +
Table 8: Embedded System Data Connector Pin Mapping Page : 45 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 15.4 Embedded system Power Connector The MCU30 is fed from one of the two inputs. Use a cable with 18 AWG gauge (or thicker) wires to connect to the connector. The connector on the MCU side is: Molex P/N: 5023520600 Figure 24: Embedded System Power Connector (MCU-30 side) MCU-30 LF10WBP-4S Description 1 2 3 4 5 6 GND (-VDC) Vin1 (+VDC) N.C Vin2 (+VDC) N.C GND (-VDC ) Table 9: Embedded System Power Connector Pin Mapping Page : 46 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual 16 Appendix D Troubleshooting Symptom Possible Cause Action Needed LED is off Not connected to power source or battery is empty 1. Verify power cable properly connected to the MCU PWR connector. 2. Verify that the battery or power supply is connected to the MCU power cable and to a power outlet. 3. Replace the battery or check the outlet. 4. Replace the power cable. LED light is always on MPTMP Not sync with 1PPS MPTMP :
PTP Unit is in boot mode 1. Verify GPS antenna is connected to AUX connector. 2. Verify the antenna can see the sky. 3. Using the MC-EMA, verify that the antenna type is configured correctly
(Active/Passive) and change it if required. 4. Replace the GPS antenna. PTP 1. Check the power source 2. Reboot the MCU. Cannot connect to MCU using MC-EMA 1. The PC isnt configured 1. Verify your PC is set with a static IP with a correct static IP in the subnet of 192.168.131.xxx. 2. Using incompatibility MC-
2. Check that the ETH port is set to EMA version
(PTP/MPTMP) 3. Unit isnt powered up auto negotiation on. 3. Verify the unit is powered up. 4. Verify that the PC ETH port status 4. Ethernet cable isnt isnt unplugged or disabled. connected or damaged data cable 5. Firewall is blocking traffic 6. ETH port set to auto negotiation off with 1GE 7. Trying to connect to remote unit when link is down. 5. Disable the PC firewall 6. Verify ETH cable is connected to the PCs ETH port and to the MCU MAIN connector. If needed: replace cables. 7. Verify using PTP-EMA for a PTP configured MCU and MP2MP-EMA to MPTMP configured MCU. 8. Ping the unit. 9. Try to connect to the local MCU and verify link is up Page : 47 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd No link between MCUs 1. Configuration isnt the same on all of the MCUs. 2. PTP both MCUs set as VC or both as Node. MPTMP many MCUs uses the same ID. 3. The MCUs arent MCU-30 User Manual 1. Connect to each MCU and verify they have the same configuration
(Frequency, profile, and Transmission Vector (for MPTMP only) 2. PTP -Verify 1 unit is set as a VC and the other as a Node. MPTMP - verify each transmitting MCU have different unit ID. within reception range 3. Verify that TX power is set to the maximum. 4. Verify the antennas fit the used Frequency (antenna spec). 1. Verify that the data bandwidth sent to the unit from the connected device(s) does not exceed the allocated bandwidth (in its configuration). 2. Decrease the data received by the data source or change the allocated bandwidth via MC-EMA Data with high delay and disconnecting data Trying to send higher amount of data the allocated bandwidth set to in the unit. than Page : 48 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Federal Communications Commission (FCC) Statement Labelling requirement for small device statement (FCC15.19(3)) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Radio Frequency Interference (RFI) (FCC 15.105) This equipment has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Labeling Requirements (FCC 15.19) This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications (FCC 15.21) Changes or modifications to this equipment not expressly approved by Mobilicom LTD. may void the users authority to operate this equipment. RF Exposure info ( FCC 2.1093) This equipment has been approved for mobile applications where the equipment must be used at distances greater than 20cm from the human body. Operation at distances less than 20 cm is strictly prohibited Page : 49 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd MCU-30 User Manual Corporate & EMEA Headquarters Mobilicom Ltd. 31 HaMetsuda Street, POB 11320, Azor 58001, ISRAEL Telephone: +972 777 10 30 60 Fax: +972 775 17 40 50 info@mobilicom.com Company's Sales Mobilicom's Headquarters: SalesHQ@mobilicom.com Europe: SalesEurope@mobilicom.com North America: SalesAmerica@mobilicom.com Technical Support Inquiries For technical support on all Mobilicom products, please contact Telephone: +972 777 10 30 60 Support@mobilicom.com Marketing, Media and Analyst Inquiries Marketing:marketing@mobilicom.com Page : 50 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd Feb 14, 2018 MCU-30 User Manual Suppliers Declaration of Conformity We, Mobilicom LTd Address: 31 Hametzuda St, Azur, Israel Declare under our sole responsibility that the product and in combination with our accessories:
Product name:
Trade name:
Accessories:
MCU-30 MCU30 None To which this declaration relates is in conformity with the requirements of the following specifications:
ANSI C63.4 FCC 47 CFR Part 15, Subpart B, Class B Digital Device. Supplementary information:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Signature:
Name :
Yossi Segal Title : VP R&D Place and of issue : Azur Israel 14-2-2018 Page : 51 / 51 This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. No part of this document may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd
1 | Label / label location | ID Label/Location Info | 230.91 KiB |
Label + Label Location HQ address: 31 Hametzoda street, P.O.B 11320, Azur, 5200174 Israel HQ Tel: +972 777 10 30 60 | HQ Fax: +972 775 17 40 50 | Email: info@mobilicom.com www.mobilicom.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-02-26 | 2403 ~ 2478 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-02-26
|
||||
1 | Applicant's complete, legal business name |
Mobilicom ltd.
|
||||
1 | FCC Registration Number (FRN) |
0021974985
|
||||
1 | Physical Address |
Hametsuda 31
|
||||
1 |
Azur, 58001
|
|||||
1 |
Israel
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
Q88
|
||||
1 | Equipment Product Code |
MCU-30
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
Y******** S******
|
||||
1 | Telephone Number |
+972-********
|
||||
1 | Fax Number |
+972-********
|
||||
1 |
y******@mobilicom.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Mobilicom
|
||||
1 | Name |
H****** Z********
|
||||
1 | Physical Address |
31 HaMetsuda Street
|
||||
1 |
Azur, 58001
|
|||||
1 |
Israel
|
|||||
1 | Telephone Number |
+9727******** Extension:
|
||||
1 | Fax Number |
97277********
|
||||
1 |
h******@mobilicom.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Mobilicom
|
||||
1 | Name |
B****** P******
|
||||
1 | Physical Address |
31 HaMetsuda Street
|
||||
1 |
Azur, 58001
|
|||||
1 |
Israel
|
|||||
1 | Telephone Number |
+9727******** Extension:
|
||||
1 | Fax Number |
97277********
|
||||
1 |
b******@mobilicom.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Communication unit used for security, robotics & surveillance | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is composite conducted. This device must be professionally installed. Authorised for use with diploe antennas of maximum gain +2 dBi. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Qualitech
|
||||
1 | Name |
M**** B******
|
||||
1 | Telephone Number |
972-3********
|
||||
1 | Fax Number |
972 3********
|
||||
1 |
M******@ecitele.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2403.00000000 | 2478.00000000 | 0.9480000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC