all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.44 MiB | June 09 2011 / July 09 2011 | |||
1 | Cover Letter(s) | June 09 2011 / July 09 2011 | ||||||
1 | Cover Letter(s) | June 09 2011 / July 09 2011 | ||||||
1 | Cover Letter(s) | June 09 2011 / July 09 2011 | ||||||
1 | External Photos | July 09 2011 | ||||||
1 | Attestation Statements | June 09 2011 / July 09 2011 | ||||||
1 | Internal Photos | June 09 2011 / July 09 2011 | ||||||
1 | ID Label/Location Info | July 09 2011 | ||||||
1 | RF Exposure Info | June 09 2011 / July 09 2011 | ||||||
1 | Test Setup Photos | June 09 2011 / July 09 2011 | ||||||
1 | Test Report | June 09 2011 / July 09 2011 |
1 | User Manual | Users Manual | 1.44 MiB | June 09 2011 / July 09 2011 |
Monnit Wireless Sensors and iMonnit Online Monitoring System User Guide Monnit Wireless Sensors and iMonnit Online Monitoring System User Guide 1 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Contents FCC Information to Users About Monnit System Requirements The Monnit Wireless Hardware MonnitLink USB Sensor Network Software Installation Hardware Installation (Bringing Sensors Online) MonnitLink USB Driver Installation Monnit Gateway Application Installation Using the iMonnit System Logging into iMonnit.com iMonnit User Interface (Overview) Using My Account (Account and Contacts) Selecting the Date Range Using the Sensor List Configuring Sensors (Basic) Configuring Sensors (Advanced) Configure Multiple Sensors Simultaneously Setting Up Notifications and Alerts History and Chart Views Exporting Data (To File) Exporting Data to an External Source Sensor Maps Reports Error Reporting, Troubleshooting and Support Warranty Information 3 4 5 6 10 11 12 14 15 17 18 19 20 21 23 24 26 27 28 29 30 31 31 2 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. FCC Information to Users This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by Monnit could void the users authority to operate the equipment. RF Exposure WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. 3 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. About Monnit Corp. Monnit is a leader in the design and manufacture of turnkey, self-installing, low cost wireless sensor solutions targeted at the commercial, industrial and consumer markets. Monnits sensing solutions are designed to be easily installed and used by anyone wanting to remotely monitor information and activities, including: access, presence of water, luminosity, temperature, humidity, and vibration in or around structures, machinery, and various environments. Please Read Before Proceeding THE WIRELESS SENSORS ARE ACTIVE AND HAVE ALREADY BEEN ASSIGNED TO YOUR CUSTOMER SENSOR NETWORK. YOUR WAR-
RANTY IS INVALIDATED IF YOU DISASSEMBLE OR ATTEMPT TO DISASSEMBLE ANY OF THESE DEVICES. 4 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Network and Computer Requirements MonnitLink USB Gateway Computer System Requirements To use your wireless sensors with a MonnitLink USB Gateway you will need a Windows PC with the following:
A MonnitLink USB Wireless Gateway Windows XP with 512 MB Memory
(Windows 7 with 1024 MB Recommended) 20 MB Free Disk Space ASP.NET 3.5
( http://www.asp.net/downloads/essential ) MonnitLink Ethernet Gateway To use your wireless sensors with a MonnitLink Ethernet Gateway you will need the following:
A MonnitLink Ethernet Wireless Gateway An Internet enabled router with one available Ethernet port or a direct internet ethernet connection. MonnitLink Cellular Gateway To use your wireless sensors with a MonnitLink Cellular Gateway you will need the following:
A MonnitLink Cellular Wireless Gateway A MonnitLink Cellular Data Plan. 5 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Monnit Wireless Hardware Monnit wireless sensor networks consist of MonnitLink Wireless Gateways, Monnit WIT Wireless Sensors and Monnit Sensor Monitoring Software such as iMonnit On-
line, Monnit Express PC Software and Monnit Enterprise Server Software. The simplest way to get started with Monnit wireless sensors is to select either a USB or Ethernet version of the gateway and monitor your sensors online through the iMonnit Online Sensor Monitoring and Notification System. MonnitLink USB Gateways require the use of a personal computer running windows XP or later and requires that the computer remain running and connected to the internet in able for the sensors to communicate to the online system. A MonnitLink Ethernet Gateway is a standalone unit that oper-
ates continuously without the need for a computer and only requires an Ethernet connection with access to the Internet. A MonnitLink Cellular Gateway is a standalone unit that op-
erates continuously without the need for a computer and only requires an Internet data plan available through Monnit. RF Specifications Operating Frequency Power Output Receiver Sensitivity RF Range Modulation 902 MHz - 928 MHz
+8 dBm
-102 dBm 250 - 300 ft. non-line-of-sight Frequency Shift Keying (FSK) 6 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. MonnitLink Ethernet Gateway RP SMA Antenna Rugged Plastic Enclosure Indicator Lights Power Plug Control Button Ethernet Port RP SMA Antenna Connector Contains FCC ID: ZTL-RFSC1 & IC: 9794A-RFSC1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the antennas listed below, and having a maximum gain of 5.0 dB. Antennas not included in this list or having a gain greater than 5.0 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. Approved Antenna:
Hyperlink HG905RD-RSP (omnidirectional) 7 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. MonnitLink Cellular Gateway RP SMA Antenna Rugged Plastic Enclosure Contains FCC ID: ZTL-RFSC1 & IC: 9794A-RFSC1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the antennas listed below, and having a maximum gain of 5.0 dB. Antennas not included in this list or having a gain greater than 5.0 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. Approved Antenna:
Hyperlink HG905RD-RSP (omnidirectional) 8 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. MonnitLink USB Gateway 4 Whip Antenna USB Interface Rugged Plastic Enclosure FCC ID: ZTL-RFUSB1 & IC: 9794A-RFUSB1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the attached non-removable antenna. 9 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Monnit WIT Wireless Sensors Battery Removal Hole 4 Whip Antenna Rugged Plastic Enclosure External Sensor Battery Slot Mounting Tabs Contains FCC ID: ZTL-RFSC1 & IC: 9794A-RFSC1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the attached non-removable antenna. 10 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Monnit Wireless Repeater RP SMA Antenna Rugged Plastic Enclosure Power Plug Contains FCC ID: ZTL-RFSC1 & IC: 9794A-RFSC1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the antennas listed below, and having a maximum gain of 5.0 dB. Antennas not included in this list or having a gain greater than 5.0 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. Approved Antenna:
Hyperlink HG905RD-RSP (omnidirectional) 11 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. MonnitLink USB Sensor Networks
(The following information is for sensor networks using a MonnitLink USB Gateway. If using a MonnitLink Ethernet or Cellular Gateway skip to page 12.) Before inserting the MonnitLink USB Gateway into your comput-
er, you will need to install the USB Drivers and the Monnit Gate-
way Application which will allow your sensor network to communi-
cate with the iMonnit Online Sensor Monitoring System. Note: If you purchased the Monnit Express standalone PC applica-
tion, then you will have received an email with download and installation instructions. If you have lost the email please contact a Monnit represen-
tative to have the email resent. USB Driver Installation MonnitLink The latest MonnitLink USB drivers can be installed directly from the web or downloaded for manual installation. http://www.monnit.com/support/downloads.php From the downloads page, click on MonnitLink USB Driver In-
staller to launch the web installer download. The driver file should automatically start downloading, if prompted to save the file, select a location that is easily accessible and click Save. When the file has completed downloading, browse to the folder where the file was saved. Double click the Monnit-Driver-Setup. exe file and select Run. Select Next then follow the on-screen guide to install the drivers. When the setup has finished, the program will automatically de-
termine which drivers to install for your system and another guide will launch to guide you through the installation of the drivers. Click Next to install the drivers. When the drivers are done installing you will see a success screen. Click Finish to exit the installation program. Note: To manually install the driver you can download the appropriate file from the downloads page and follow the included instructions. 12 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Monnit Gateway Application Installation The Monnit Gateway Application allows your wireless sensors to communicate with the iMonnit Online Sensor Monitoring and Notification System. (iMonnit allows you to view all your sensor data, sensor status and configure all sensor parameters as well as setup notifications or alerts via sms text and email.) To install the software, open a web browser and navigate to http://www.monnit.com/support/downloads.php. From the down-
loads page, click on Monnit Gateway Application Installer to launch the web installer download. If prompted to save the file, select a location that is easily accessible and click Save. When the file has completed downloading, browse to the folder where the file was saved. Double click the MonnitGatewaySetup. msi file, select Run when prompted then follow the on-screen instructions to complete the installation. When installation is complete the program will automatically launch. You can now begin using your Monnit wireless sensors online. Note: The Monnit Gateway application needs to be running on your computer in order for the sensor data to be transmitted to the iMonnit Online System. If the gateway is not running your sensor data is not being recorded and notifications based on sensor data cannot be sent from the system. 13 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Bringing Sensors Online Launch the Monnit Gateway Application:
From the Windows Start Menu under All Programs >
Monnit click on Monnit Gateway.
(Skip this step if using an Ethernet or Cellular Gateway) Insert the MonnitLink USB Wireless Gateway:
With the Monnit Gateway application running, insert the MonnitLink USB into your computer. The network status in the software should change to active when the USB gateway has been plugged in.
(If the status does not change, try unplugging and re-inserting the USB gateway.)
(Skip this step if using an Ethernet or Cellular Gateway) Insert batteries into the sensors:
Peel back the black sticker cover of the battery slot and slide the coin cell battery into the sensor. It will power on within 10-20 seconds. fig.1 Battery Insertion Note: Note the proper orientation of battery in fig.1. When inserting, make sure to push the battery all the way back. _
Check that Sensor Data is Being Recieved:
As the sensors power up, they will check into the Monnit-
Sphere Gateway and transmit their current reading. Your gateway window should look similar to this:
RSSI: -21 / -31, Volts: 2.96V, STS: 16, Data: 72.3 F 06/24/2011 09:44:57.939: RX: Sensor Data: Device: 10721 SensorType: Temperature[2], 06/24/2011 09:44:57.375: RX: Status Indication: Device: 10721 has joined network 06/24/2011 09:44:42.274: RX: Network Status: APN: 2116, NetCNT: 4, Channel: 4, Network Active NetID: 248, MODE: "ACTIVE/RESUME"
14 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Continued... If a sensor does not join the network when a battery is inserted, try cycling the power by removing and re-inserting the battery. (You should wait 45 seconds before re-inserting the battery.) Once you have verified that your sensors are all powered on and have checked into the MonnitSphere Gate-
way they are ready to be deployed. If you wish to change a sensor configuration, all of the parameters are editable in the MonnitSphere online software. The new parameters will be downloaded to the Wireless Gateway every 5 minutes, then transmitted to the sensors on their next heartbeats. If you need more immediate response from a sensor, you can press the Download Sensor Updates button in the Monnit Gateway applicaton, then cycle the sensor by removing, then re-inserting the battery. 15 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Using the iMonnit Online System Logging into iMonnit Open any Internet Browser and navigate to the iMonnit website at www.imonnit.com. Enter your username and password in the appropriate field and click the Login button to continue. Your username and password are included on the informa-
tion sheet that shipped with your sensors. Note: You will be prompted to change your password when you login for the first time. 16 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. iMonnit User Interface (Overview) 1. Menu System 4. Current Sensor Quick Stats s r o t i a c d n I s u a S t t r o s n e S
. 3 2. Sensor List 5. Sensor Data Window Menu System Provides quick links to areas of the software for navigational purpose. Network Overview Displays a list of all wireless sensor networks associated with the account. Clicking on a network name will change the current view to the selected network. Sensor Maps Visual Tool for uploading a building blueprint or schematic, allowing you to visually place sensor tags on the map. Clicking on the sensor graphics gives you a quick view of the latest sensor reading and status. My Account Access and edit account information and system users. Reports Access reports for your account. 17 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Sensor List Displays all sensors that are currently assigned to your sen-
sor network. Clicking on a sensor name allows you to select which sensor information is viewable on-screen. Clicking the edit button by a sensors name allows you to change the sensor specific settings such as sensor name and heartbeat
(report interval) as well as advanced sensor configuration information that is stored on the sensor hardware. Sensor Status Indicators Displays the status for each individual sensor. Sensor is checking in and within user defined safe parameters. Sensor has not checked in. Sensor has met a user defined threshold or triggered event. Current Sensor Quick Stats Displays the most current information from the selected sensor, including: sensor name, signal strength, battery power and sensor reading / status. Sensor Data Window The sensor data window displays content according to the selected sensor data tab. There are four different views available. History - Displays a history of the data sent from the selected sensor. Alerts - Allows you to view, create, edit or delete user customizable notifications for the selected sensor. Chart
- Displays a graphical view of the readings sent from the selected sensor. Export - You can archive data by exporting as a .csv file or send the sensor data to an external source. Calibrate - Allows you to calibrate your sensors by correcting a current reading, and applying the adjustment to all future readings. (Only available on applicable sensors.) 18 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Using My Account (Account and Contacts) Clicking on the My Account link in the navigation bar will open the account settings page. From here you have the ability to edit your account information, manage users, and create a master recipient for all messages from the system. Edit Account Information Allows you to change general account information such as; com-
pany name, address, time zone and primary contact. Create New Account User Allows you to create new users for the account by entering contact information and sensor network permissions. Edit Account User Allows you to change contact information, change login password and change sensor network permissions. Edit Sensor Networks Allows you to change the name of the sensor network and enable or disable notifications for all sensors located in that network. Configure All Notification Recipient Allows you to create a contact that will overwrite all existing notifi-
cations for all sensors and networks within the account. Note: Using this function will overwrite all existing notifications setup in the account. 19 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Selecting the Date Range All of the sensor information viewed through the user interface is selectable by a Date Range. The default view for the system is the past 30 days. To change this simply click on the date range box at the top of the sensor data window. After clicking on the date range box, the following pop-up win-
dow will appear. You can click on any of the pre-determined date configurations in the left column or select Pick a Date to view single day data for a given date or select Date Range to define a specific range of dates. Note: The current date is highlighted in yellow, while your selected dates will be displayed in red. 20 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Using the Sensor List The sensor list provides a quick view of the status for all sensors in the selected network as well as providing quick link access to sensor data and configuration windows. The following is a summary of the status indicators and what they mean. Sensor is checking in and within user defined safe parameters. Sensor has not checked in for the past 3 heartbeats. Sensor has met a user defined threshold or triggered event. Clicking on the name of a sensor in the list opens the sensor dis-
play view and clicking on the Edit icon by each name opens the sensor configuration window. List Options (Sorting the Sensor List) For larger sensor networks, we have provided a way to easily sort your sensor list to only show sensors by Type or Status. To activate a sorting filter on the list, mouse over List Options and select the filter you would like to apply. To reset to the default sensor list view select Reset View. 21 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Configuring Sensors (Basic) Click the Edit icon next to the name of the sensor that you would like to configure. (You can also click on the Edit tab in the sen-
sor information window.) The basic sensor configuration window allows you to set the primary configurations for each sensor. The basic configurations will suffice for the majority of users. Within this window you can name your sensor, set the heartbeat (how frequently the sensor will take a reading and communicate with the MonnitSphere online monitoring and notification system), and select the units of mea-
surement etc. If more advanced configurations are needed, click on Advanced Configuration link above the Save button. Note: Be sure to click the Save button anytime you make a change to any of the configuration elements. 22 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Configuring Sensors (Advanced) All of the advanced configuration settings are transmitted to the sensor and stored on the sensor hardware. These settings allow the sensor to act differently, independent of the software. 23 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Advanced Sensor Setting Definitions Inactivity Alert (Minutes) The amount of time that elapses without a heartbeat before you are noti-
fied. The default is 3 times the set heartbeat interval. Active Between The time of day the sensor is actively working. No communication will be sent while sensor is hibernating. Assessments per Heartbeat How many times between heartbeats a sensor will check its measure-
ments against its thresholds to determine whether it will enter the aware state. Minimum Threshold Any assessments below this value will cause the sensor to enter the aware state. Maximum Threshold Any assessments above this value will cause the sensor to enter the ware state. Hysteresis A buffer to prevent the sensor from bouncing between standard operation and the aware state when the assessments are very close to a threshold. For example, if a maximum threshold is set to 90 and the hysteresis is set to 1, when a sensor takes an assessment of 90.0 and enters the aware state it will remain in the aware state until the temperature reading drops to 89.0. Similarly, at the minimum threshold the temperature will have to rise 1 above the threshold to return to standard operation. Transmission Offset In large sensor networks, offset is used to prevent all sensors from trans-
mitting simultaneously; therefore minimizing communication disruption. Aware State Heartbeat How often the sensor communicates with the gateway while in the aware state. 24 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Configure Multiple Sensors Simultaneously You can make certain configurations to multiple sensors by click-
ing on Configure Multiple Sensors at the bottom of the Sensor List Window. Click the checkboxes in front of all sensors that you would like to apply the settings to, then click Save to apply the same settings for all selected sensors. Note: Settings configured through this window will overwrite any custom settings currently set for the selected sensors. 25 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Setting Up Notifications and Alerts Clicking on the Notifications tab within the sensor data window will bring up a list of sent notifications as well as a list of all currently setup notifications and alerts. New Edit Delete To create a new notification or alert, click on the New icon at the bottom right of the window. To edit or delete an existing notification, click on the Edit icon or the Delete icon. 26 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Creating a New Notification or Alert Person to Notify Start typing a name into the box and the system will show all users with a similar name, if you need to create a new user click Add New. Type of Notification Allows you to choose the notification delivery method (Email or SMS.) Notification Text This is a user defined message that will be emailed or texted to the recipient when the conditions have been met. Sensor Conditions for Alert This area is dependant upon what type of sensor is being used. For example a temperature sensor will ask for a condition that when met will trigger the alert, such as a temperature above 80. Notify Again After Allows you to define how frequently you want to be notified if the sensor condition is still met or exceeded. For example, if the temperature is still above 80 I can be notified every 10 minutes until I have addressed the issue. Notification is On Allows you to turn off a notification temporarily, without deleting it. 27 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. History and Chart Views Clicking on the History or Chart tabs within the sensor data window allows you to view the sensor data history as text or in a graphical chart. To change the date range of the viewable information, click on the date range box at the top right of the sensor data window. 28 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Exporting Data Clicking on the Export tab within the sensor data window allows you to export sensor data to a comma separated value (.csv) file or send the sensor data to an external web source. To export sensor data to a comma separated value (.csv) file for use in spreadsheet software such as Microsoft Excel, click on Export Data at the bottom of this window. The default value will export data for the viewed sensor only, if you would like to include data for all sensors in the viewed network, click the checkbox by Include Data from All Sensors. Note: Only the first 5,000 records within the selected date range will be exported, you can adjust the date range to export more data if needed. 29 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Exporting Data to an External Source To send the sensor data to an external web source, click on Con-
figure External Source. On this page you can select the External Data Subscription Type which can be a Generic URL or an external service that is cur-
rently registered with the MonnitSphere System such as Sensing Planet. If you are using a registered external subscription ser-
vice enter your External Identifier and Connection Information. All available parameters are listed on the page. 30 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Sensor Maps By clicking on Sensor Maps in the main navigation bar you can access MonnitSpheres Visual Sensor Mapping Tool. This tool allows you to upload a graphic of your building or sensor area, and visually place sensor tags on the graphical map to remind you where sensors have been placed. The tool also allows for one click access to current sensor readings and status. To create a new sensor map, click on the New icon. In the pop-
up window, type a name for your map and then click Choose File to browse your computer for the graphic you would like to upload. Click Create to save the map to your list. Once your map is created, you can add sensors from your sensor list to the map by clicking on Add to Map by each sensor. 31 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Once the sensors have been added to the map they will disappear from the sensor list and a sensor image will appear on the map. You can move the sensor tags on the map by single click and holding to drag. Right click on a sensor image for a context menu to remove a sensor from the map. Once the sensors have been placed where you like, you can view a sensors status and last reading by mousing over the sensor tag. Single clicking on a sensor image will open a pop-up window showing its current readings and sensor history. You can close this view by clicking the X in the upper right corner of the pop-up window. Reports By clicking on Reports in the main navigation bar you can access any standardized reports generated by the MonnitSphere software system. To suggest a report idea email software@monnit.com with a full description. 32 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. Error Reporting, Troubleshooting and Support For technical support and troubleshooting tips please visit our support library online at http://www.monnit.com/support/. If you are unable to solve your issue using our online support, email Monnit support at support@monnit.com with your contact information and a description of the problem, and a support representative will call you within one business day. For error reporting, please email a full description of the error to support@monnit.com. Warranty Information
(a) Monnit warrants that Monnit-branded products will be free from defects in materials and workmanship for a period of one (1) year from the date of delivery with respect to hardware and will materially conform to their published specifica-
tions for a period of one (1) year with respect to software. Monnit may resell sen-
sors manufactured by other entities and are subject to their individual warranties;
Monnit will not enhance or extend those warranties. Monnit does not warrant that the software or any portion thereof is error free. Monnit will have no warranty obligation with respect to Products subjected to abuse, misuse, negligence or accident. If any software or firmware incorporated in any Product fails to conform to the warranty set forth in this Section, Monnit shall provide a bug fix or software patch correcting such non-conformance within a reasonable period after Monnit receives from Customer (i) notice of such non-conformance, and (ii) sufficient information regarding such non-conformance so as to permit Monnit to create such bug fix or software patch. If any hardware component of any Product fails to conform to the warranty in this Section, Monnit shall, at its option, refund the purchase price less any discounts, or repair or replace non-conforming Products with conforming Products or Products having substantially identical form, fit, and function and deliver the repaired or replacement Product to a carrier for land shipment to customer within a reasonable period after Monnit receives from Cus-
tomer (i) notice of such non-conformance, and (ii) the non-conforming Product provided; however, if, in its opinion, Monnit cannot repair or replace on com-
mercially reasonable terms it may choose to refund the purchase price. Repair parts and replacement products may be reconditioned or new. All replacement products and parts become the property of Monnit. Repaired or replacement products shall be subject to the warranty, if any remains, originally applicable to the product repaired or replaced. Customer must obtain from Monnit a Return Material Authorization Number (RMA) prior to returning any Products to Monnit. Products returned under this Warranty must be unmodified. Customer may return all Products for repair or replacement due to defects in original materials and workmanship if Monnit is notified within ninety (90) days of customers receipt of the product. Monnit reserves the right to repair or replace products at its own and complete discretion. Customer must obtain from Monnit 33 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. a Return Material Authorization Number (RMA) prior to returning any products to Monnit. Products returned under this Warranty must be unmodified and in original packaging. Monnit reserves the right to refuse warranty repairs or replacements for any products that are damaged or not in original form. For products outside the ninety-day warranty period repair services are available at Monnit at standard labor rates for a period of one year from the Customers original date of receipt.
(b) As a condition to Monnits obligations under the immediately preceding para-
graphs, Customer shall return Products to be examined and replaced to Monnits facilities, in shipping cartons which clearly display a valid RMA number provided by Monnit. Customer acknowledges that replacement products may be repaired, refurbished or tested and found to be complying. Customer shall bear the risk of loss for such return shipment and shall bear all shipping costs. Monnit shall deliver replacements for Products determined by Monnit to be properly returned, shall bear the risk of loss and such costs of shipment of repaired products or replacements, and shall credit Customers reasonable costs of shipping such returned Products against future purchases.
(c) Monnits sole obligation under the warranty described or set forth here shall be to repair or replace non-conforming products as set forth in the immediately preceding paragraph, or to refund the documented purchase price for non-con-
forming Products to Customer. Monnits warranty obligations shall run solely to Customer, and Monnit shall have no obligation to customers of Customer or other users of the Products. Limitation of Warranty and Remedies. THE WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY APPLI-
CABLE TO PRODUCTS PURCHASED BY CUSTOMER. ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. MONNITS LIABIITY WHETHER IN CONTRACT, IN TORT, UNDER ANY WARRANTY, IN NEGLI-
GENCE OR OTHERWISE SHALL NOT EXCEED THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT. UNDER NO CIRCUMSTANCES SHALL MONNIT BE LIABLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAM-
AGES. THE PRICE STATED FOR THE PRODUCTS IS A CONSIDERATION IN LIMITING MONNITS LIABILITY. NO ACTION, REGARDLESS OF FORM, ARIS-
ING OUT OF THIS AGREEMENT MAY BE BROUGHT BY CUSTOMER MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS ACCRUED. IN ADDITION TO THE WARRANTIES DISCLAIMED ABOVE, MONNIT SPECIFI-
CALLY DISCLAIMS ANY AND ALL LIABILITY AND WARRANTIES, IMPLIED OR EXPRESSED, FOR USES REQUIRING FAIL-SAFE PERFORMANCE IN WHICH FAILURE OF A PRODUCT COULD LEAD TO DEATH, SERIOUS PERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE SUCH AS, BUT NOT LIMITED TO, LIFE SUPPORT OR MEDICAL DEVICES OR NUCLEAR APPLICATIONS. PRODUCTS ARE NOT DESIGNED FOR AND SHOULD NOT BE USED IN ANY OF THESE APPLICATIONS. 34 |
M-UG01-3A | www.monnit.com | 2011 Monnit Corp. For additional information on Monnit Wireless Sensors and Software, please visit us on the web at www.monnit.com. Monnit Corporation 7304 South Cottonwood Suite #204 Midvale, Utah 84047 www.monnit.com All trademarks are property of Monnit. 2011 Monnit Corp. All Rights Reserved. M-UG01-3A (7/11)
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2011-09-07 | 903 ~ 927 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2011-09-07
|
||||
1 | Applicant's complete, legal business name |
Monnit Corporation
|
||||
1 | FCC Registration Number (FRN) |
0020736583
|
||||
1 | Physical Address |
450 South Simmons Way
|
||||
1 |
Kaysville, Utah 84037
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
v******@ultratech-labs.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
ZTL
|
||||
1 | Equipment Product Code |
RFUSB1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B******** W****
|
||||
1 | Title |
CEO
|
||||
1 | Telephone Number |
80159********
|
||||
1 | Fax Number |
80159********
|
||||
1 |
b******@monnit.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | MonnitLink USB Wireless Gateway | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 | Grant Comments | Output power listed is conducted. This device must not be co-located or operating in conjunction with any other antenna or transmitter. No restriction on use as per RF Exposure Compliance shown in the filing. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UltraTech Engineering Labs Inc.
|
||||
1 | Name |
T****** L******
|
||||
1 | Telephone Number |
905-8********
|
||||
1 | Fax Number |
905-8********
|
||||
1 |
t******@ultratech-labs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 903.00000000 | 927.00000000 | 0.0061000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC