MONUMEMT PELLET GRILL USE AND CARE MANUAL S1251801T Please read this entire manual before installation and use of this pellet fuel -burning appliance. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Save these instructions. THIS Pellet Grill IS DESIGNED FOR OUTDOOR USE ONLY SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE WWW.MONUMENTGRILLS.COM 1. Safety warning page 3-4 Guide directory 2. Certification sticker Page 5 3. Exploded View Page 6 4. Single part list Page 7 5. Fixing elements Page 7 6. Mounting steps Page 7--18 7. Use of smoked stove Page 19-20 8. Button function description Page 21-23 9. Troubleshooting common faults Page 23 1.Safety warning Please read the entire manual carefully before assembling and using the smoker, and install and use it as required. The company will not be responsible for property damage, personal injury or even death caused by failure to follow the instructions. About carbon monoxide poisoning: All cooking ovens or cooking utensils produce organic gases (such as carbon monoxide) when burning materials
(such as wood, gas or charcoal). Carbon monoxide can impair the ability of the blood to deliver oxygen, which can lead to loss of consciousness or death. If you have headaches, dizziness, weakness, nausea, vomiting, nasal congestion, lethargy or confusion in your use, please seek medical advice. Be sure to use the device in an open area outside and away from inflammable and explosive materials (minimum 40 inches). This equipment is equipped with an ignition system. Do not use gasoline, gasoline fuel, kerosene, barbecue charcoal or special ignition liquid to ignite. Please use the grounding socket that meets the local safety regulations. If you need to reinstall the socket, please follow the local electrical code. Dangerous voltage can cause shock, burns or death. In case of equipment failure, please follow the instructions or contact the local after-sales personnel for maintenance. Please cut off the power before maintenance. During the use of the device, there is a high temperature in the local position. Do not move the device at will, and pay attention to the elderly and children. Beware of burns. Please clean up the remaining fuel after each use, because the fuel may expand and clogging the feeding mechanism. Please use the wood pellets for the smoker to ensure that the particle diameter is not more than 0.3 inches and the length is not more than 1.2 inches. If the particles are too large, the equipment may be extinguished due to poor feeding. FCC Part l5 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNINGChanges or modifications, to this equipment not expressively approved by the party responsible for compliance could void the users authority to operate the equipment. FCC RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide separation distance of at least 20cm from all persons. 2. Certification label 3. Exploded View 4. Single part list Seq. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Cast iron grill Oil guide plate Chimney cover assembly Chimney assembly Chimney insulation cotton Fire board Furnace assembly Ash tray Frame support plate Short leg Shelf Shelf cover axle Body floor 6 inch transparent wheel 5. Fixing elements Appellation Qty Appellation Qty Seq. NO. 16 17 18 19 20 21 22 23 24 25 26 Long legs Burning chamber handle Barbecue probe Control box assembly power cable Control box handle assembly Control box screen Control box cover Combustion chamber assembly Cover panel Upper cover handle assembly 2 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 2 2 1 2 2 2 1 6. Mounting steps Make sure your grill is assembled properly. Detailed assembly instructions are packed with each grill giving specific assembly procedures for each model. Follow these instructions carefully to ensure the correct and safe assembly of the grill. Caution: Although we take every effort to ensure that the assembly process is as easy as possible, it is inherent with fabricated steel parts that corners and edged can cause cuts if improperly handled during assembly procedures. Be careful while handling any parts during assembly. It is strongly recommended that you protect hands with a pair of work gloves. A B C D x36 x4 x15 x4 A8PCS 0.2in A4PCS A4PCS The screws have been pre assembled A2PCS B2PCS A8PCS C8PCS A2PCS C2PCS The screws have been pre assembled B2PCS D4PCS The screws have been pre assembled Please pay attention to protect the temperature probe during installation to prevent damage A5PCS C5PCS A3PCS 7. Use of smoked stove 7.1 Placement of equipment The smoke oven should be placed in an open and ventilated place, at least as shown in the surrounding fixed facilities, and away from inflammable and explosive materials. 7.2 Fuel selection The smoked stove should use standard wood pellet fuel. This kind of fuel can be purchased in local surrounding stores. Users can purchase fuel of different materials according to personal preference, but the particle size of fuel should not exceed 1.2x0.3. Large fuels may cause the equipment to go out due to poor feeding. 7.3 Confirmation before power on Before powering on the equipment, you should re-confirm the surrounding power environment, and the socket and plug are not wet or the wiring is bare. 7.4 Button interface 40"
12"
12"
1.2"MAX 0.3"MAX 7.5 Ignition instructions Clean the remaining ash in the combustion chamber before each ignition. Then pour new fuel into the control box, not to exceed the control box screen (about 2/3), and then put a small amount of new fuel into the combustion chamber. The fuel is pyramid-shaped to cover the best layer of the ignition rod 1~2. Then place the fire plate, the oil guide plate and the grilling net in turn, close the lid, turn on the Power button, and select the desired mode. The device starts to ignite. White smoke will be emitted during the ignition of the fuel, and personnel can stay away from the operating equipment after waiting for the ignition to complete. It should be noted that in order to save electricity, the ignition rod will only work when the Cook or Smoke mode is selected for the first time after power-on. In other cases, it does not work. Therefore, if the fuel is not ignited, the power should be turned off first. Key, then turn the Power button back on and select the appropriate mode to re-ignite. 7.6 Device shutdown After the barbecue is over, please turn off the equipment safely:
First of all, please open the top cover of the control box, remove the excess fuel from the box, and keep it for future use. Then, let the equipment continue to work for 5 to 10 minutes to drain the fuel in the feeder;
Next, click the Power button to turn it off, but don't unplug the power immediately. At this point, the cooling fan will continue to work for 5 minutes until the fuel is burned out and extinguished. Finally, please unplug the power supply and store the oven in a cool, ventilated place, avoiding sun exposure and heavy rain. Not exceeding the filter screen igniter 8. Button function description The key is the device key, the key is turned on, other keys can be operated, the key is closed, the device is in the stop state, other key operations are invalid, and the corresponding keys in the APP have the same function. This button is the cooking button. When it is turned on, it enters the normal cooking mode. The corresponding icon on the LCD screen lights up. The user can select the default setting or set the cooking temperature by itself. (The SET area of the LCD screen will display correspondingly.) The button is a smoked button. When it is turned on, it enters the smoke mode. The corresponding icon on the LCD screen lights up. The user can select 1 (small smoke) or 2 (too smoke) file (LCD SET area will be There is a corresponding display), the app will automatically synchronize with the device.The device can only choose one mode to work in the cooking button and the smoke button. No matter which mode is selected, the other mode will be automatically turned off. The button is the probe opening key (the external barbecue probe needs to be connected). When the probe is turned on, the probe is enabled, the corresponding icon on the LCD screen is lit, the user can select the default setting, or set the cooking temperature by himself (the LCD SET area will be Corresponding display), the app will automatically synchronize with the device. The corresponding key in the app has the same function. After the setting is completed, the device starts to work. After the set temperature is reached, the device will b eep. You can press any button to cancel the beep. If there is no 2 minutes. The operation will automatically stop. Press and hold for 3 seconds to exit this mode. Display priority is higher than and This button is the timed key. When it is turned on, it enters the countdown mode. The corresponding icon on the LCD screen lights up. Select the default setting, you can also set the countdown time yourself (the LCD screen SET area will have corresponding display), the App will automatically synchronize with the device, the corresponding key in the App has the same function, the device starts working after the setting is completed, after the set time, the device The beep will prompt, you can press any key to cancel the buzzer, if there is no operation for 2 minutes, it will stop automatically. Press and hold for 3 seconds to exit this mode. When this key is enabled, the display priority is higher than This key is the key to the child lock. When it is turned on, it enters the child lock mode. At this time, the operation of any key is invalid, mainly to prevent children from misoperation. The button needs to be pressed for 3 seconds to unlock. After unlocking, other buttons can be used again. The app will automatically sync with the device, and the correspon ding keys in the app have the same function. This button is the unit switching button. The Fahrenheit temperature is displayed by default. It can display Celsius temperature after lighting, or switch back to Fahrenheit. The corresponding icon on the LCD will automatically switch. The app will automatically synchronize with the device, and click the temperature display position in the center of the App interface to achieve unit switching. This button is a digital up button, and each time you click, th e number
"+1" is completed. This button is a digital drop button, and each time you click, the number
"-1" operation is completed. Every time the above keys are successfully operated, the device will have a beep sound, please pay attention. If the sensor in the furnace is poorly connected or damaged, the LCD panel will display Err and the device will not work. The fan will continue to operate for 5 minutes to prevent fuel re-ignition each time the key is turned on for shutdown. If the temperature of the sensor in the furnace is lower than 120 F for 15 minutes, the device will beep for 2 minutes to indicate that the combustion is extinguished. Press any key to cancel the buzzer. If there is no operation for 2 minutes, it will stop automatically. 9. Troubleshooting common faults Fault description Troubleshooting The equipment not on fire is Fuel is not ignited The fuel particles are too large to enter the feeder Troubleshooting Try to re-ignite Replace small pellet fuel Feed screw stop Check if the circuit is abnormal or replace Ignition rod is not heated the feed motor Check if the circuit is abnormal or replace the ignition rod LCD displays "Err"
In-furnace sensor failure Check or replace the furnace sensor Beep alarm The barbecue probe reaches the set temperature Press any key to cancel the buzzer Timing arrival time Smoker is extinguished Press any key to cancel the buzzer Refueling Grilled probe is not connected Connecting barbecue probe Poor connection or damage furnace sensor to the Replace the furnace sensor