Instruction Manual Contents For your safety Notes on use/Cleaning instructions 1. Components 2. Setting up (Sensor Stand) 3. Charging Sensor 4. Charging Rechargeable battery 5. Changing Rechargeable battery (Sensor) Troubleshooting USB connection with the designated device Specifications 2 4 9 12 14 15 16 18 21 22 This manual contains important information regarding the safe use of this product. Read all the safety and operating instructions before operating the product. For your safety The precautions described in this manual are to ensure safe use of the unit and to prevent harm or injury to you and others. The manufacturer and vendor of this product take no responsibility for any personal injury or other accidental damage that may occur as a result of incorrect or inappropriate use of the product. In particular, be sure to read the manual to ensure that you are familiar with all aspects of safety in using this unit. After reading this manual, keep it in a safe place for further reference when necessary. Warning Failure to follow the instructions will cause danger which will almost certainly result in death or serious injury. Do not get this unit wet. Do not use it with your wet hand. Doing so may cause electric shocks or malfunction. Do not shine the light from this unit directly to the eye. Doing so may damage eyesight. Do not disassemble, repair or modify (e.g. by soldering) the unit. Doing so may cause an accident, fire or electric shocks. Do not leave the unit in places where it may be exposed to high temperatures such as direct sunlight, a heat source and flame (e.g., inside a vehicle during summer). Doing so may increase the internal temperature and cause explosion or fire. Do not use this unit in places where it may be exposed to oil fumes, steam, high humidity, chemicals or dust. Water, oil, grime, humidity or dust inside the unit may damage the internal components. It may also cause malfunction, smoking or fire. Stop using this unit, turn off the power and remove the batteries immediately if any of the following occurs: water or a foreign object entering inside the unit; damage to the outer case; overheating;
smoking; odor. Failure to do so may cause fire or electric shocks. In case of lightening, disconnect the AC adapter from the outlet and do not touch metallic parts of this unit or the batteries. Failure to do so may cause electric shocks from a lightning strike. Do not place this unit near electrical equipment that uses a high-
precision control device or weak electrical signal (including electronic medical devices in your body). Failure to do so may cause malfunction in the other equipment. For your safety Caution Failure to follow the instructions may result in personal injury or physical damage to equipment and surroundings. If liquid crystal leaks from the screen, do not handle with bare hands. Doing so may cause skin irritation. Should hands or clothing come in contact, wash immediately with water. Do not insert a finger or metal object like a wire into the unit. Doing so may cause personal injury and damage to the unit. Keep out of the reach of children to prevent injury. Do not leave the lens facing directly toward the sun or other source of strong light. It may cause fire or damage internal components. Do not use this unit inside a vehicle such as an airplane. Electromagnetic waves emitted by this unit may interfere with the vehicle. Do not use near medical instrument such as inside a hospital. Notes on use Do not use this unit for purposes other than skin analysis. This unit is precision equipment. Do not drop or knock it against other objects. If this unit is subjected to any strong shocks, it may result in malfunction. Do not place or use in a location where it will be exposed to grime or dust. They may get inside the sensor and damage the unit. Only use the included lithium-ion rechargeable batteries, and set them in the correct direction. Failure to do so may cause overheating, fire and damage. When used for an extended period of time, Sensor may feel warm. This will not affect performance or quality. If it feels unusually hot, turn off the power and then remove the batteries. Remove the batteries when the unit is not in use for a long time to avoid leakage and loose connection. If the unit has not been used for a long time, the battery may lose power through self-discharge. Change it or charge before use. Do not place on an unstable surface. Dropping may result in an accident or injury. A rapid change in temperature may cause condensation. If condensation occurs, do not use the unit immediately. Wait until it is dry before use. Do not use near a cell phone or a microwave treatment device. It may not function properly due to magnetism. When attaching a strap, use a durable one to prevent dropping the unit. Dropping may damage the unit. Do not use the USB cable for devices other than the specified device. It may result in damage or malfunction. Cleaning instructions Remove Rechargeable batteries. Do not clean with solvent such as benzene or paint thinner. Use a dry cloth to wipe the display screen. Do not clean the interior of the camera inside the tip of Sensor. It may damage the lens or the light, and result in malfunction. About wireless LAN (IEEE802.11a, IEEE802.11b,IEEE802.11g,IEEE802.11n If the radio equipment uses the above listed 2.4GHz band channels, you can use all the bandwidth and avoid channels used by radio-frequency identification readers. It employs DSSS modulation method and OFDM modulation method, and the interference range is 40m. This unit uses the same frequency band as other industrial, scientific, and medical equipment including a microwave oven, as well as radio-frequency identification readers (radio stations requiring the license) and specified low power radio frequency station (requiring no license) used in factories and manufacturing lines. 1) Before using this unit, be sure there is no specified low power radio frequency station or radio-frequency identification reader in use nearby. If this unit interferes with a radio-frequency identification reader, immediately stop data transmission and contact Support Center for further instructions. 2) Depending on your wireless LAN environment including the structure/material of the building, obstacles, software and signal transmission, the speed of the connection will vary. Note the connection may also slow down or be interrupted. Check with the airline before carrying this unit on an airplane. About the 5GHz band channels This unit can use the 5GHz band. It uses the following channels. Note, in Japan (Radio Act) and some countries, laws prohibit use of 5.2GHz and 5.3GHz bands outdoor. W52 (5.2GHz band/36,40,44,48ch) W53 (5.3GHz band/52,56,60,64ch) W56 (5.6GHz band/100,104,108,112,116,120,124,128,132,136,140ch) Use of Wi-Fi is subject to local laws and regulations in your country/region. Directive on Waste Electrical and Electronic Equipment
[WEEE] (2012/19/EU) This product shall be compliant with WEEE marking requirements
(2012/19/EU). Hereinafter, the CE marking indicates that this electronic equipment shall not be waste as household waste. manufacturer is compliant with all applicable legal requirements of the EU New Approach Directives and European Regulations. When they are disposed of within the European community, please contact Europe of SHISEIDO. Make sure the electronic equipment waste should not be disposed of in the regular trash as household waste. HSS products are a built-in battery type. If you are selling them in the E.U., you are required to provide the product data complying with the revised Directive on Waste Electrical and Electronic Equipment [2012/19/EU]. Since the internal batteries of HSS products cannot be replaced, when they are disposed of, they are collected and disassembled in accordance with the WEEE directive. Then, the batteries shall be recycled based on the WEEE directive. Thus, when the HSS products are disposed of within E.U., please contact Europe of SHISEIDO. When you need the Product Data Sheet related to the internal batteries
(issued by battery manufacturer), please ask for it to Europa of SHISEIDO. FCC / IC Compliment statement Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Cet quipement a t test et trouv conforme aux limites pour un appareil numrique de Classe B, conformment la partie 15 des rgles FCC. Ces limites sont conues pour fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre une nergie de frquence radio et, s'il n'est pas install et utilis conformment aux instructions, peut causer des interfrences nuisibles aux communications radio. Cependant, il n'y a aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interferences nuisibles la rception radio ou tlvision, ce qui peut tre dtermin en teignant l'quipement, l'utilisateur est encourag essayer de corriger les interfrences en prenant une ou plusieurs des mesures suivantes :
Rorientez ou dplacez l'antenne de rception. Augmenter la distance entre l'quipement et le rcepteur. Connecter l'quipement une prise sur un circuit diffrent de celui auquel le rcepteur est connect. Consulter le revendeur ou un technicien radio/tlvision expriment. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. L'opration est soumise aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interfrences, et (2) cet appareil doit accepter toute interfrence, y compris les interfrences pouvant entraner un fonctionnement indsirable de l'appareil. RF exposure compliance This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet metteur ne doit pas tre localis ou fonctionner avec toute autre antenne ou metteur. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourrait annuler l'autorisation d'utilisation de l'quipement. 1. Components Sensor
(Front)
(Back) LED lamp Power switch Mode select button Measurement button Tip of Sensor
(Side) Connector cover Battery compartment cover Strap hole
(With Battery compartment cover open) Close-up Serial number
*It is printed on the inside. Cable hole cover
(With Connector cover open)
(With Cable hole cover open) MicroSD card slot
*Turn off the power when removing the Connector cover. Cable hole cover Cable hole
(The cable passes through here.)
*If you remove Cable hole cover, store safely in a packaging box.
*Serial number is printed on Sensor (in Battery compartment) and on Sensor stand (on the back and the back of the skin tone calibration plate). 1. Components Sensor stand
(Front)
(Back) Skin tone calibration plate Cable guide Serial number Close-up USB connector
(With Skin tone calibration plate cover open)
(Seen from the top) Serial number Skin tone calibration plate RGB Value
*Serial number and the value shown here are an example. Battery slot Skin tone calibration plate LED lamp 1. Components USB cable, miscellaneous AC adapter (for Sensor stand) AC USB adopter Connector for Sensor stand Connector for AC adopter
*Use when you connect the cable to Sensor stand. USB cable (for Sensor, with a bushing) Rechargeable battery (2 pcs) Connector for Sensor Connector for the designated device
*Use when you connect Sensor to the designated device. Contact Support Center before use. Locking screw Connector stopper Insert each battery to Sensor and Sensor stand. Locking screw and Connector stopper are attached to Sensor stand.
*Do not lose any parts including the packaging box. 2. Setting up (Sensor stand) 1. Connect AC adapter (for Sensor stand) to Sensor stand. USB connector 2. Loosen Locking screw, secure USB connector with Connector stopper, and then tighten Locking screw. Locking screw Connector stopper 2. Setting up (Sensor stand) 3. Insert the cable on AC adapter (for Sensor stand) through Cable guide.
*Handle with care and do not damage the cable. Cable guide 4. Place Sensor stand on a flat surface. Plug AC adapter into an electrical outlet. Electrical outlet Caution Only use included AC adopter (for Sensor stand). Using other AC adopters may result in damage and malfunction of Sensor and Sensor stand. 3. Charging Sensor 1. Slide Sensor in from the top of Sensor stand to place it properly. Caution Sensor will not charge if it is placed in a wrong direction or not set in place properly. 2. Sensor stand will charge the battery inside Sensor. LED lamp LED lamp indication Charging LED lamp on Sensor turns red. Fully charged LED lamp on Sensor turns green. Caution If you place Sensor on Sensor stand while it is turned off, it will still charge but LED lamp will not turn on. 4. Charging Rechargeable battery 1. Insert Rechargeable battery into Sensor stand in the correct direction. The indentation on the left 2. Sensor stand will charge it. LED lamp Follow the direction indicated by the triangle. Caution It will not charge if it is inserted in a wrong direction. LED lamp indication Charging LED lamp on Sensor stand turns red. Fully charged LED lamp on Sensor stand turns green. Caution If Sensor is on Sensor stand at the same time, it will charge Sensor but not the inserted Rechargeable battery. LED lamp on Sensor stand will blink in green. 5. Changing Rechargeable battery (Sensor) Warning Never use Rechargeable battery if it is inflated. It may cause overheating, fire or explosion. 1. Remove Battery compartment cover. Push the corners of Battery compartment cover with your fingers and slide until a gap opens at the bottom. Lift Battery compartment cover to open. Remove Rechargeable battery. Caution Turn off the power when removing the Battery compartment cover. 5. Changing rechargeable battery (Sensor) 2. Insert fully charged Rechargeable battery. Be sure to insert rechargeable battery to the battery compartment with triangle mark on battery matches to the same mark in the housing as shown. Also, you may find slotted groove on the left side on the battery. Fully insert Rechargeable battery. 3. Close Battery compartment cover. Follow the direction 1 in reverse order and close tightly. Caution Assembly which is not specified in this chapter may cause damage or malfunction of the products. Troubleshooting Sensor Symptom Solution It does not turn on. When it turns on, the skin tone calibration screen appears. It stopped working during operation.
(The screen froze.) The screen display does not look right. The screen is blank/ the display disappeared. Check Is Rechargeable battery correctly inserted to Sensor?
Is it charged?
Solution Change to charged Rechargeable battery. When you turn it on, press down on Power switch for 2-3 seconds. The Handy Skin Sensor logo will appear. Solution When you first turn it on for the day, the skin tone calibration screen appears. After the second time, the top page will appear. Solution Turn it off, and turn it back on again.
*If it does not turn off, remove Rechargeable battery. Solution Turn it off, and turn it back on again.
*If it does not turn off, remove Rechargeable battery. Check If the unit is left unused for a while, it automatically goes into standby and turns off the screen. Is LED lamp blinking in white (standby mode)?
Solution Press Power switch on Sensor to check if the screen comes back on. Turn it off, and turn it back on again.
*If it does not turn off, remove Rechargeable battery. Troubleshooting Sensor Symptom The display is dark. Solution Check Is the brightness of the screen set too low?
Is there a strong source of light nearby?
Solution Change the brightness. (For instructions on how to change the setup, refer to Counter Utilization Manual.) Try using away from the strong source of light. I cannot turn it off. Solution Press down on Power switch for 5 seconds.
*If it does not turn off, remove Rechargeable battery. I cannot change the mode with Mode select button. Solution Turn it off, and turn it back on again.
*If it does not turn off, remove Rechargeable battery.
*Mode select button only works on the enlarged shooting screen. Sensor is on Sensor stand but it is not charging. Check If you are using a power strip, is it plugged into an electrical outlet properly?
Is AC adapter connected to Sensor stand and an electrical outlet properly?
Is Sensor placed on Sensor stand properly?
Is Rechargeable battery inserted properly in Sensor?
Solution
*If Battery compartment cover is off, Sensor will not charge.
*LED lamp turns red when Sensor is charging. Troubleshooting Sensor Symptom The result value of Skin Tone analysis is displayed on an extreme position like corners of the screen. LED lamp on Sensor is flashing in red. Sensor stand Symptom LED lamp on Sensor stand is flashing in red. Solution Check Do the serial number for Sensor and the serial number for Sensor stand match?
Solution Make sure to pair Sensor and Sensor stand by the serial number and calibrate skin tone from the setup screen. (To find the serial number, refer to p7-8 of this manual.) Solution There is a problem with recharging (overloaded current, overheating). Stop use immediately. Remove Sensor from Sensor stand and unplug AC adopter from an electrical outlet. Contact Support center. Solution Solution There is a problem with recharging (overloaded current, overheating). Stop use immediately. Remove Sensor from Sensor stand and unplug AC adopter from an electrical outlet. Contact Support center. USB connection with the designated device 1. To connect the designated device, use USB cable (for Sensor, with a 2. Remove Battery compartment cover, and remove Rechargeable battery bushing). and Cable hole cover. 3. Connect the correct end of USB cable
(for Sensor, with a bushing). As illustrated, circle once inside the compartment and securely place the bushing. USB Connector Bushing 4. Fully insert Rechargeable battery back in place, and close Battery compartment cover. Rechargeable battery Caution Rechargeable battery must be inserted to connect. 5. Connect the other end of USB connector to the designated device. Caution Turn off the power when removing the Battery compartment cover. Specifications Sensor Measure mode Screen size CMOS Camera Optical lens Lighting OS CPU Memory LCD Touch panel Wireless LAN External interface Power consumption Power source Battery life
(When fully charged) LED lamp indication Weight Dimensions inch CMOS camera sensor 5.55 5.55 m 640 (H) 480 (V) pixel 3 group/ 4 element 8.0 0.58x Super Luminosity White LED/DIP implementation 8 lights / Lamp type 8 lights / Lamp type 8 lights / Lamp type 1GB DDR3 Micro SD 8GB (Micro SD slot Primary) 4.0TFT LCD 480 800 260,000 IEEE802.11a, b, g, n (2.4 / 5GHz) WEP, WPA2/AES Infrastructure Wireless LAN access point (2.4GHz) Texture / Polarized / Skin Tone Approx. 43 times (With 14-inch monitor) Imaging element Pixel size Pixel count Element F value Optical magnification Lamp type Texture mode Polarized mode Skin tone mode Android 5.1.1 ARM Cortex A9 Dual 1GHz Main storage capacity Internal memory Screen size Resolution Displayable colors Capacitive Correspondence standards Security Access method USB (Micro-B type) 2-port microSD Approx. 2W Lithium-ion rechargeable battery *Capacity3120mAh
(Included) Full operation
(Connected to wireless LAN, with lights on, and shooting) Standby
(Not connected to wireless LAN, with lights off) LED off Red Green White Blinking in red Approx. 200g (without battery) Approx. 64 (W) 171 (H) 58.6 (D) mm Approx. 6 hours Approx. 70 minutes Power OFF Charging Power on Standby (Power ON/Charging/Abnormal) Abnormal (Overloaded current/Overheating) Specifications Sensor stand LED lamp indication Power source Weight Dimensions LED off Red Green Blinking in green Blinking in red Via AC adapter Approx. 330g (without AC adapter or cable) Approx. 82 (W) 62 (H) 176 (D) mm Not connected to power Charging the battery in Sensor stand Connected to power Charging Sensor Abnormal (Overloaded current/Overheating) AC adopter (for Sensor stand) Connector Length Input voltage Output voltage Output current Weight Dimensions USB cable For Sensor, with a bushing For sensor: Micro B type For an electrical outlet: plug 1.5m 100-240V 5VDC 1.8A Approx. 69g Approx. 51 (W) 19 (H) 48 (D) mm A type Micro B 1m For Sensor: Micro B type For PC: A type Rechargeable battery (Lithium-ion rechargeable battery) Capacity Weight Dimensions Charge time 3120mAh (70 minutes in full operation) 60g Approx. 43 (W) 69 (H) 12 (D) mm Less than 4 hours (Empty Full charge) Specifications Equipment Name: Handy Skin Sensor Model Name: HSS U.S.A FCC ID: 2AO35-HSS2 Canada IC: 23766-HSS2