all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual Part 1 | Users Manual | 2.19 MiB | January 12 2004 | |||
1 |
|
Users Manual Part 2 | Users Manual | 3.08 MiB | January 12 2004 | |||
1 | Cover Letter(s) | January 12 2004 | ||||||
1 | Operational Description | January 12 2004 | ||||||
1 | Cover Letter(s) | January 12 2004 | ||||||
1 | External Photos | January 12 2004 | ||||||
1 | Internal Photos | January 12 2004 | ||||||
1 | ID Label/Location Info | January 12 2004 | ||||||
1 | Cover Letter(s) | January 12 2004 | ||||||
1 | RF Exposure Info | January 12 2004 | ||||||
1 | Test Report | January 12 2004 | ||||||
1 | Test Report | January 12 2004 | ||||||
1 | Test Setup Photos | January 12 2004 |
1 | User Manual Part 1 | Users Manual | 2.19 MiB | January 12 2004 |
NPort W2004 Series Users Manual First Edition, November 2004 www.moxa.com/product Moxa Technologies Co., Ltd. Tel:
+886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide:
The Americas support@moxa.com.tw support@moxa.com NPort W2004 Series Users Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright 2004 Moxa Technologies Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Trademarks Disclaimer All other trademarks or registered marks in this manual belong to their respective manufacturers. MOXA is a registered trademark of The Moxa Group. Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa. Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time. Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use. This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication. Table of Contents Chapter 4 Chapter 3 Chapter 2 Chapter 1 Introduction ..................................................................................................1-1 Overview.................................................................................................................................. 1-2 Package Checklist.................................................................................................................... 1-2 Product Features ...................................................................................................................... 1-3 Product Specifications ............................................................................................................. 1-3 Serial Port Pin Assignments..................................................................................................... 1-4 Getting Started .............................................................................................2-1 Panel Layout ............................................................................................................................ 2-2 Connecting the Hardware ........................................................................................................ 2-2 Wiring Requirements.................................................................................................... 2-3 Connecting the Power................................................................................................... 2-3 Connecting to the Network........................................................................................... 2-3 Connecting to a Serial Device ...................................................................................... 2-4 LED Indicators ............................................................................................................. 2-4 Initial IP Address Configuration .................................................................3-1 Installation Procedure for First-time Users.............................................................................. 3-2 Factory Default IP Address ...................................................................................................... 3-2 Telnet Console ......................................................................................................................... 3-3 Serial Console (19200, n, 8, 1)................................................................................................. 3-6 Choosing the Proper Operation Mode .......................................................4-1 Overview.................................................................................................................................. 4-2 TCP Server Mode .................................................................................................................... 4-2 TCP Client Mode ..................................................................................................................... 4-3 UDP Mode ............................................................................................................................... 4-3 Real COM Mode...................................................................................................................... 4-4 Chapter 5 Web Console Configuration........................................................................5-1 Configuring Your Browser....................................................................................................... 5-2 Time Settings ........................................................................................................................... 5-4 Network Settings...................................................................................................................... 5-5 General Settings............................................................................................................ 5-5 Ethernet Configuration ................................................................................................. 5-6 WLAN Configuration................................................................................................... 5-7 Serial Port Settings................................................................................................................. 5-10 Operation Modes ........................................................................................................ 5-10 Communication Parameters........................................................................................ 5-19 System Management.............................................................................................................. 5-21 Misc. Network Settings .............................................................................................. 5-21 Auto Warning Settings ............................................................................................... 5-25 System Status.............................................................................................................. 5-29 Change Password........................................................................................................ 5-32 Installing and Configuring the Software ....................................................6-1 Overview.................................................................................................................................. 6-2 Installing NPort COM Driver .................................................................................................. 6-2 Installing NPort Search Utility................................................................................................. 6-5 Configuring NPort COM Driver.............................................................................................. 6-9 Configuring NPort Search Utility .......................................................................................... 6-17 Chapter 6 Real TTY and Fixed TTY Installation ................................................................................... 6-19 Installing the Real TTY driver.................................................................................... 6-19 Installing the fixed TTY driver................................................................................... 6-21 Appendix A SNMP Agents with MIB II & RS-232 Like Groups ..................................... A-1 Appendix B Well Known Port Numbers ......................................................................... B-1 Appendix C Service Information..................................................................................... C-1 MOXA Internet Services..........................................................................................................C-2 Problem Report Form ..............................................................................................................C-3 Product Return Procedure........................................................................................................C-4 Appendix D Federal Communication Commission Interference Statement............... D-1 11 Introduction Chapter 1 Moxas NPort W2004 Series of wireless serial device servers give you an easy way to connect your RS-232/422/485 serial devices to a WLAN. The 4-port NPort W2004 is ideal for environments where a LAN is not available, or where serial devices are moved frequently. The following topics are covered in this chapter:
! Overview
! Package Checklist
! Product Features
! Product Specifications
! Serial Port Pin Assignments NPort W2004 Users Manual Introduction Overview Moxas NPort W2004 wireless device server is the ideal choice for connecting your RS-232/422/485 serial devicessuch as PLCs, meters, and sensorsto a Wired Ethernet LAN and Wireless LAN. Your communications software will be able to access the serial devices from anywhere over a local LAN, WLAN, or the Internet. Moreover, the WLAN environment offers an excellent solution for applications in which the serial devices are moved frequently from place to place. NPort W2004 wireless serial device servers support automatic IP configuration protocols (DHCP) and manual configuration via a handy web browser console. Both IP configuration methods ensure quick and effective installation, and the NPort Windows Driver Manager Utility makes Port Mapping very convenient to configure. An external antenna increases the range of the wireless connection. Users can position the adjustable antenna for maximum signal strength or even replace the antenna with their own for additional flexibility and scalability. This feature is particularly useful when a serial device is connected in a high interference area. As an added feature, a signal strength indicator is located on the front panel to make it easier to troubleshoot connection problems. NPort W2004 wireless serial device servers ensure the compatibility of network software that uses a standard network API by providing TCP Server Mode, TCP Client Mode, and UDP Mode. The Real COM/TTY drivers allow software that works with COM/TTY ports to be set up to work over a TCP/IP network in no time. This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly. To make your management task easier, the NPort W2004 Series provides additional features, such as password authentication, IP filter, WEP support for 64-bit and 128-bit encryption, and SNMP support. Package Checklist Power adaptor NPort W2004 is shipped with the following items:
Standard Accessories
! NPort W2004 x 1
! Documentation & Software CD
! RJ45 to RJ45 Ethernet cross-over cable
! RJ45 to male DB9 cable
! RJ45 to female DB9 cable
! Warranty Booklet
! Quick Installation Guide Optional Accessories
! DK-35A DIN-Rail Mounting Kit (35 mm)
! CBL-RJ45M9-150 (8-pin RJ45 to male DB9 cable; 150 cm)
! CBL-RJ45F9-150 (8-pin RJ45 to female DB9 cable; 150 cm)
! CBL-RJ45M25-150 (8-pin RJ45 to male DB9 cable; 150 cm)
! CBL-RJ45F25-150 (8-pin RJ45 to male DB9 cable; 150 cm) NOTE: Notify your sales representative if any of the above items is missing or damaged. 1-2 NPort W2004 Users Manual Product Features Introduction 4 RS-232/422/485 ports, at up to 460.8 Kbps Supports Windows and Linux Real COM drivers
! Connect any serial device to WiFi 802.11g/b network
! Web-based configuration via built-in Ethernet of WLAN
! Versatile socket operation modes, including TCP Client/Server, pair connection, and UDP
! Auto MDI/MDIX function Product Specifications Secure data access via standard WEP Enhanced remote configuration via HTTPS and SSH WLAN Standard Compliance Radio Frequency Type Tx Power 11b Tx Power 11g Rx Sensitivity Transmission Rate Transmission distance Security Antenna Connector Network Mode LAN Ethernet Protection Serial No. of ports Interface Port Type RS-485 Data direction 802.11g/b DSSS, OFDM 18 dBm 2 dBi 16 dBm 2 dBi
-70 dBm @ 54 Mbps, -85 dBm @ 11 Mbps 54 Mbps (max.) with auto fallback
(54, 48, 36, 24, 18, 12, 11, 9, 6, 5.5, 2, 1 Mbps) Up to 300 meters (@ 12 Mbps, in open areas) WEP 64-bit/128-bit data encryption Reverse SMA Infrastructure mode, Ad-Hoc mode 10/100 Mbps, RJ45 Built-in 1.5 KV magnetic isolation 4 RS-232/422/485, with 15 KV ESD for all signals 8-pin RJ45 ADDC (patented Automatic Data Direction Control) Serial Communication Parameters Parity Data Bits Stop Bits Flow Control Transmission Speed None, Even, Odd, Space, Mark 5, 6, 7, 8 1, 1.5, 2 RTS/CTS, XON/XOFF 50 bps to 460.8 Kbps Console Ports Ethernet console x 1 RS-232 console x 1 10/100M LAN, 8-pin RJ45 8-pin, RJ45 1-3 NPort W2004 Users Manual Introduction Software Features Protocols Utilities Configuration Power Requirements Power Input Power Consumption ICMP, IP, TCP, UDP, DHCP, Telnet, DNS, SNMP, HTTP, SMTP, SNTP, SSH, SSL, HTTPS Windows utility for Windows 98/ME/2000/XP/2003 Web browser, serial/telnet console, or Windows utility 12-48 VDC 685 mA @ 12V; 184 mA @ 24V, 340 mA @ 24V Mechanical Specifications Material SECC sheet metal (1 mm) Environmental Operating Temperature Storage Temperature Regulatory Approvals EMC Safety 0 to 60C (32 to 140F), 5 to 95%RH
-20 to 85C (-4 to 185F), 5 to 95%RH FCC Class A, CE Class A UL, CUL, TV Serial Port Pin Assignments 8-pin RJ45 Port 1 8 RS-232/422/485 Pinouts Pin 1 2 3 4 5 6 7 8 RS-232 DSR RTS GND TxD RxD DCD CTS DTR RS-422
TxD+
GND TxD-
RxD+
RxD-
RS-485
(4-wire)
TxD+
GND TxD-
RxD+
RxD-
RS-485
(2-wire)
GND
Data+
Data-
1-4 22 Chapter 2 Getting Started This chapter includes information about installing NPort W2004. The following topics are covered in this chapter:
! Panel Layout
! Connecting the Hardware
" Wiring Requirements
" Connecting the Power
" Connecting to the Network
" Connecting to a Serial Device
" LED Indicators NPort W2004 Users Manual Panel Layout Getting Started Reset button Power inputs Antenna Top View DIN-Rail Mount Signal Strength LEDs Ready WLAN P1 P2 P3 P4 LEDs 10M LED Ethernet port 100M LED Serial Console port 8-pin RJ45 serial ports P3 P1 r e v r e S e c i v e D Signal Strength Ethernet RS-232 Console P4 5 8 4
2 2 4
2 3 2
S R P2 NPort W2004 Front View Side View Connecting the Hardware This section describes how to connect NPort W2004 to serial devices for first time testing purposes. We cover Wiring Requirements, Connecting the Power, Connecting to the Network, Connecting to a Serial Device, and LED Indicators. 2-2 NPort W2004 Users Manual Wiring Requirements ATTENTION Getting Started Safety First!
Be sure to disconnect the power cord before installing and/or wiring your device. Wiring Caution!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment. Temperature Caution!
Be careful when handling the device. When plugged in, the devices internal components generate heat, and consequently the casing may feel hot to the touch. You should also pay attention to the following items:
! Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. NOTE: Do not run signal or communication wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
! Use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
! Keep input wiring and output wiring separate.
! Where necessary, it is advisable to label the wiring to all devices in the system. Connecting the Power Connect the 12-48 VDC power line with NPort W2004s power jack. When the power is supplied properly, the Ready LED will show a solid red color until the system is ready, at which time the
Ready LED will change to a green color. Connecting to the Network Connect one end of the Ethernet cable to NPort W2004s 10/100M Ethernet port and the other end of the cable to the Ethernet network. If the cable is properly connected, NPort W2004 will indicate a valid connection to the Ethernet in the following ways:
The Ethernet LED maintains a solid green color when connected to a 100 Mbps Ethernet network. The Ethernet LED maintains a solid orange color when connected to a 10 Mbps Ethernet network. The Ethernet LED will flash when Ethernet packets are being transmitted or received.
2-3 NPort W2004 Users Manual Connecting to a Serial Device Getting Started Connect the serial data cable between NPort W2004 and the serial device. Serial data cables are optional accessories for NPort W2004. Refer to Chapter 1 under Optional Accessories in the Ordering Information section for information about the RJ45-to-DB25 and RJ45-to-DB9 cables. LED Indicators LED IndicatorsThe front panel of NPort W2004 has eleven LED indicators, as described in the following table. LED Name LED Function LED Color Steady onPower is on and NPort is booting up. Blinking fast (once every 0.5 sec)Indicates a LAN IP conflict. Blinking slowly (once every sec)Looking for an IP when no DHCP server is available. Steady onPower is on and NPort is functioning normally. Blinking fast (once every 0.5 sec)Loading factory default configuration after holding in the reset button for 5 seconds. Blinking slowly (once every sec)The device server has been located by NPort Search utility. Power is off, or power error condition exists. OnWireless enabled. Blinking fast (once every 0.5 sec)Indicates a WLAN IP conflict. Blinking slowly (once every sec)Looking for an IP when no DHCP server is available. Serial port is receiving data. Serial port is transmitting data. No data is being transmitted or received through the serial port. These 5 LEDs are used to indicate the WLAN signal strength, in increments of 20%. The bottom LED of these 5 will be lit when the WLAN links to the access point. 10 Mbps Ethernet connection 100 Mbps Ethernet connection Ethernet cable is disconnected, or has a short. red green off green orange green off green orange green off Ready WLAN P1, P2, P3, P4 Signal Strength
(5 LEDs) 10/100 M Ethernet 2-4 33 Initial IP Address Configuration Chapter 3 When setting up your NPort W2004 for the first time, the first thing you should do is configure the IP address. Select one of the initial IP Address configuration methods to configure NPort W2004s IP Address. For more details about network settings, see the Network Settings section from Chapter 5, Web Console Configuration. This chapter covers the following topics:
Installation Procedure for First-time Users
! Factory Default IP Address
! Telnet Console
! Serial Console (19200, n, 8, 1) NPort W2004 Users Manual Initial IP Configuration Installation Procedure for First-time Users STEP 1: After removing NPort W2004 from the box, use a cross-over Ethernet cable to connect directly to your computers Ethernet port. STEP 2: Attach the power adaptor to the NPort W2004 and then plug the adaptor into an electrical outlet. STEP 3: Use the Web console to configure the NPort W2004 via the Ethernet port. NOTE We recommend that you use the web console to configure NPort W2004. See Chapter 5 for instructions on how to use the web console. Factory Default IP Address static IP 192.168.126.254 255.255.255.0 NPort W2004 is configured with the following default IP addresses:
LAN:
Setting IP Address Netmask
# If the Ethernet port is unable to get an IP address from the DHCP server, then the IP address/netmask will revert to 192.168.126.254/255.255.255.0. WLAN:
Setting IP Address Netmask
# If the WLAN port is unable to get an IP address from the DHCP server, then the IP address/netmask will revert to 192.168.127.254/255.255.255.0 static IP 192.168.127.254 255.255.255.0 NOTE NOTE NOTE If you forget the IP address, you can use the NPort Search utility (from your PC) to locate the NPort W2004 unit over the network. You will be able to view the IP address on the screen. Only one Network Interface can be used at the same time. If the Ethernet Link is active, then the WLAN will be disabled. If the WLAN is active, then the Ethernet Link will be disabled. The default login parameters are: username = admin, and password = blank. 3-2 NPort W2004 Users Manual Telnet Console Initial IP Configuration 1. From the Windows desktop, click on Start and then select Run 2. Type telnet 192.168.126.254 (default IP address) in the Open text input box, and then click
: NPW2004_20
: NPort W004-US on OK. When the Telnet window opens, if you are prompted to input the Console password, input the password and then press Enter .Note that this page will only appear if the NPort W2004 is password protected.
Host Name Model Name LAN MAC Address : 00:90:e8:93:04:36 WLAN MAC Address : N/A Serial No
: 20 Firmware Version : 0.0.1.1_beta6
<< Main Menu >>
(1) Time Settings
(2) Network Settings
(3) Serial Port Settings
(4) System Management
(q) Quit 3. Type 2 to select Network settings, and then press Enter.
: NPW2004_20
: NPort W004-US
Host Name Model Name LAN MAC Address : 00:90:e8:93:04:36 WLAN MAC Address : N/A Serial No
: 20 Firmware Version : 0.0.1.1_beta6
<< Main Menu >>
(1) Time Settings
(2) Network Settings
(3) Serial Port Settings
(4) System Management
(q) Quit Key in your selection: 2 4. Type 2 to select Ethernet Configuration and then press Enter. 3-3 NPort W2004 Users Manual Initial IP Configuration
<< Main Menu >>
(1) General Settings
(2) Ethernet Configuration
(3) WLAN Configuration
(4) View Settings
(5) Back to the Main Menu
(6) Quit Key in your selection: 2 5. Type 2 to select IP Address and then press Enter, then use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter.
<< Main Menu->Network Settings->Ethernet Configuration >>
(1) IP Configuration
(2) IP Address
(3) Netmask
(4) Gateway
(v) View Settings
(m) Back to Main Menu
(q) Quit Key in your selection: 2 IP Address : 192.168.126.254 6. Type m and then press Enter to return to the main menu.
<< Main Menu->Network Settings->Ethernet Configuration >>
(1) IP Configuration
(2) IP Address
(3) Netmask
(4) Gateway
(v) View Settings
(m) Back to Main Menu
(q) Quit Key in your selection: m 7. Type 4 to select System Management, and then type 4 to select Maintenance. 3-4 NPort W2004 Users Manual Initial IP Configuration
<< Main Menu >>
(1) Time Settings
(2) Network Settings
(3) Serial Port Settings
(4) System Management
(q) Quit Key in your selection: 4
<< Main Menu >>
(1) Misc. Network Settings
(2) Auto Warning Settings
(3) System Status
(4) Maintenance
(m) Back to Main Menu
(q) Quit Key in your selection: 4 8. Type 4 and then type y to Restart the system.
<< Main Menu->System Management->Maintenance >>
(1) Load Factory Default
(2) Change Password
(3) Restart Port
(4) Restart System
(m) Back to Main Menu
(q) Quit Key in your selection: 4 Are you sure to restart system?
(y) Yes
(n) No Key in your selection: y 3-5 NPort W2004 Users Manual Initial IP Configuration Serial Console (19200, n, 8, 1) Before configuring the NPort W2004 via the serial console, turn off the power and use a serial cable to connect the NPort W2004 to your computers serial port. We suggest using MOXA PComm Terminal Emulator, which can be downloaded free of charge from www.moxa.com, to carry out the configuration procedure. 1. Connect NPort W2004s serial port 1 directly to your computers male RS-232 serial port. 2. From the Windows desktop, click on Start # Programs # PComm Lite # Terminal Emulator. 3. When the PComm Terminal Emulator window opens, first click on the Port Manager menu item and select Open, or click on the Open icon. 4. The Property window opens automatically. From the Communication Parameter page, select the appropriate COM port for the connection, COM1 in this example, and 19200 for Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits. 5. From the Property windows Terminal page, select ANSI or VT100 for Terminal Type, and click on OK. If you select Dumb Terminal as the terminal type, some of the console functionsespecially the Monitor functionmay not work properly. 3-6 NPort W2004 Users Manual Initial IP Configuration Input the password when prompted. 6. 7. Start by configuring the IP address under Network Settings. Refer to the Telnet Console section for instructions on how to configure the rest of the IP settings. 3-7 44 Chapter 4 Choosing the Proper Operation Mode In this chapter, we describe the various NPort W2004 operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions. This chapter covers the following topics:
! Overview
! TCP Server Mode
! TCP Client Mode
! UDP Mode
! Real COM Mode NPort W2004 Users Manual Choosing the Proper Operation Mode Overview NPort W2004 wireless Serial Device Servers are used to network-enable traditional RS-232/422/485 devices. A Serial Device Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can bi-directionally translate data between the serial and Ethernet formats. The Serial Device Server lets you use a computer to access, manage, and configure remote facilities and equipment over the Internet from anywhere in the world. Traditional SCADA and data collection systems rely on serial ports (RS-232/422/485) to collect data from different types of instruments. Since NPort W2004 wireless Serial Device Servers network-enable instruments equipped with an RS-232/422/485 communication port, your SCADA and data collection system will be able to access all instruments connected to a standard TCP/IP network, regardless of whether the devices are used locally or at a remote site. NPort W2004 is an external IP-based network device that allows you to expand the number of serial ports for a host computer on demand. As long as your host computer supports the TCP/IP protocol, you wont be limited by the host computers limited number of conventional busses
(such as ISA or PCI), or lack of drivers for various operating systems. In addition to providing socket access, NPort W2004 also comes with a Real COM/TTY driver that transmits all serial signals intact. This means that you can continue using existing COM/TTY-based software, eliminating the need to invest in additional, costly software. Three different Socket Modes are available: TCP Server, TCP Client, and UDP Server/Client. The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender. UDP does not require this type of verification, making it possible to offer speedier delivery. UDP lets you unicast to one IP address, or multicast to groups of IP addresses. TCP Server Mode 1 TCP/IP WLAN TCP Server Mode In TCP Server mode, NPort W2004 is configured with a unique IP:Port address on a TCP/IP network. NPort W2004 waits passively to be contacted by the host computer, allowing the host computer to establish a connection with and get data from the serial device. This operation mode also supports up to 4 simultaneous connections, so that multiple hosts can collect data from the same serial deviceat the same time. As illustrated in the figure, data transmission proceeds as follows:
1. The host requests a connection from the NPort W2004 configured for TCP Server Mode. 2. Once the connection is established, data can be transmitted in both directionsfrom the host Request a connection Proceed with data transmission NPort W2004 Serial Device Serial (TTL) 2 1 2 r e v r e S e c i v e D NPort W2004 Signal Strength RS-232 Console 5 8 4
2 2 4
2 3 2
S R Ethernet Ready WLAN P1 P2 P3 P4 P4 P1 P3 P2 to the NPort W2004, and from the NPort W2004 to the host. 4-2 NPort W2004 Users Manual TCP Client Mode Choosing the Proper Operation Mode In TCP Client mode, NPort W2004 can actively establish a TCP connection to a pre-defined host computer when serial data arrives. After the data has been transferred, NPort W2004 can disconnect automatically from the host computer by using the TCP alive check time or Inactivity time settings. Refer to Chapter 5 for more details As illustrated in the figure, data transmission proceeds as follows:
1. The NPort W2004 requests a connection to the host. TCP Client Mode 1 2 Request a connection Proceed with data transmission 1 2 TCP/IP WLAN NPort W2004 Ready WLAN P1 P2 P3 P4 P3 P1 r e v r e S e c i v e D Signal Strength Ethernet RS-232 Console P4 5 8 4
2 2 4
2 3 2
S R P2 NPort W2004 Serial Device Serial (TTL) 2. Once the connection is established, data can be transmitted in both directionsfrom the host to the NPort W2004, and from the NPort W2004 to the host. UDP Mode Compared to TCP communication, UDP is faster and more efficient. In UDP mode, you can unicast or multicast data from the serial device to one or more host computers. The serial device can also receive data from multiple host computers, making this mode ideal for message display applications. UDP Mode TCP/IP WLAN Proceed directly with data transmission (connection request not required) NPort W2004 Serial Device Serial (TTL) Ready WLAN P1 P2 P3 P4 P3 P1 r e v r e S e c i v e D Signal Strength Ethernet RS-232 Console P4 5 8 4
2 2 4
2 3 2
S R P2 NPort W2004 4-3 NPort W2004 Users Manual Real COM Mode Choosing the Proper Operation Mode TCP/IP WLAN Real COM Mode NPort W2004 comes equipped with COM drivers that work with Windows 95/98/ME/NT/2000/XP systems. The driver establishes a transparent connection between host and serial device by mapping the IP:Port of the NPort W2004s serial port to a local COM port on the host computer. One of the main conveniences of using Real COM Mode is that Real COM Mode allows users to continue using RS-232/422/485 serial communications software that was written for pure serial communications applications. The driver intercepts data sent to the hosts COM port, packs it into a TCP/IP packet, and then redirects it through the hosts Ethernet card. At the other end of the connection, the NPort W2004 accepts the Ethernet frame, unpacks the TCP/IP packet, and then transparently sends it to the appropriate serial device attached to one of the NPort W2004s serial ports. Proceed directly with data transmission (connection request not required) NPort W2004 Serial Device Serial (TTL) r e v r e S e c i v e D NPort W2004 Signal Strength RS-232 Console 5 8 4
2 2 4
2 3 2
S R Ethernet Ready WLAN P1 P2 P3 P4 P1 P4 P3 P2 ATTENTION Real COM Mode allows several hosts to have access control of the same NPort W2004. The driver that comes with your NPort W2004 controls host access to attached serial devices by checking the hosts IP address. Refer to Accessible IP Settings in Chapter 5 for more details. 4-4 55 Chapter 5 Web Console Configuration The Web Console is the most user-friendly method available to configure NPort W2004 Series. This chapter introduces the Web Console function groups and function definitions. The following topics are covered in this chapter:
! Configuring Your Browser
! Basic Settings
" Time Settings
" Web/Telnet Console
! Network Settings
" General Settings
" Ethernet Configuration
" WLAN Configuration
! Serial Port Settings
" Operation Modes
" Communication Parameters
! System Management
" Accessible IP Settings
" SNMP Agent
" Auto Warning Settings
" System Status
! Change Password
! Load Factory Default
! Save/Restart NOTE You may use either a cross-over or straight-through Ethernet cable to connect NPort W2004 to a PC, Hub, Switch, or LAN/WAN port. NPort W2004s Ethernet port will auto-detect which type of cable is being used, and then adjust the signals accordingly. NPort W2004 Users Manual Web Console Configuration Configuring Your Browser Before opening your browser, you need to enable cookies. 1. To enable your browser for cookies, right click on your desktop Internet Explorer icon, select Properties, and then click on the Security tab. 2. Enable the three options shown in the figure below, and then click on OK. 5-2 NPort W2004 Users Manual Web Console Configuration 3. Type 192.168.126.254 (the default IP address) in your browsers Address box (use the correct IP address if different from the default), and then press Enter. Input the password. NPort W2004 allows only one user. The username is set to admin and the default password is also set to admin. You may NOT change the username, but you can change the password at any time. Note that the login function cannot be disabled. 4. 5. The NPort W2004 homepage will open. On this page, you can see a brief description of the Web Consoles nine function groups. ATTENTION If you cant remember the password, the ONLY way to start configuring NPort W2004 is to load factory defaults by using the Reset button, which is located near the NPort W2004s power jack. ATTENTION If you use a web browser other than Internet Explorer, remember to Enable the functions to
allow cookies that are stored on your computer or allow per-session cookies. NPort W2004 uses cookies only for password transmission. 5-3 NPort W2004 Users Manual Time Settings Web Console Configuration NPort W2004 has a built-in Real-Time Clock that allows you to add real-time information to functions such as Auto warning Email or SNMP Trap. ATTENTION First time users should select the time zone first. The Console will display the real time according to the time zone compared to GMT. If you would like to modify the real time clock, select Local time. NPort W2004s firmware will modify the GMT time according to the Time Zone. Time zone Setting User selectable time zone Local tim (yy/mm/dd)e Setting User adjustable time
(2000/1/1-2037/12/31) Factory Default GMT (Greenwich Mean Time) Factory Default GMT (Greenwich Mean Time) Necessity Optional Necessity Optional Click on the [ Modify ] button to open the Modify time settings window to input the correct local time. 5-4 NPort W2004 Users Manual Web Console Configuration Time server Setting IP Address or Domain Name
(E.g., 192.168.1.1, time.stdtime.gov.tw, or time.nist.gov) Factory Default None Necessity Optional NPort W2004 uses SNTP (RFC-1769) for auto time calibration. Input the correct Time server IP address or domain name. Once NPort W2004 is configured with the correct Time server address, NPort W2004 will request time information from the Time server every 10 minutes. Network Settings General Settings Click on the General Settings option to modify the Server name and DNS server IP addresses or domain names. Server name Setting Alphanumeric DNS server 1 / DNS server 2 Setting E.g., 192.168.1.1
(IP addresses of the form x.x.x.0 and x.x.x.255 are invalid. Factory Default NPW2004_<Serial No.>
Factory Default None Necessity Optional Necessity Optional When a user wishes to visit a particular website, the computer first requests the websites correct IP address from the Domain Name System (DNS) server, and then the computer uses the response to connect to the website. DNS represents the method used to translate Internet domain names into IP addresses. A domain name is an alphanumeric name, such as moxa.com, that it is easier to remember. A DNS server is a host that translates this kind of text-based domain name into the numeric IP address used to establish a TCP/IP connection. 5-5 NPort W2004 Users Manual Web Console Configuration In order to use NPort W2004s DNS feature, you need to configure the DNS server. Doing so allows NPort W2004 to use a hosts domain name to access the host. NPort W2004 provides DNS server 1 and DNS server 2 configuration items to configure the IP address of the DNS server. DNS Server 2 is included for use when DNS sever 1 is unavailable. Ethernet Configuration You must assign a valid IP address to NPort W2004 before it will work in your network environment. Your network system administrator should provide you with an IP address and related settings for your network. The IP address must be unique within the network (otherwise, NPort W2004 will not have a valid connection to the network). First time users should refer to Chapter 3, Initial IP Address Configuration, for more information. Choose from two possible IP configuration modesStatic and DHCPlocated under the web console screens IP configuration drop-down box. IP configuration Method Static DHCP Function Definition User defined IP address, Netmask, Gateway. DHCP Server assigned IP address, Netmask, Gateway, DNS, and Time Server. IP address Setting E.g., 192.168.1.1
(IP addresses of the form x.x.x.0 and x.x.x.255 are invalid. Factory Default 192.168.126.254 Necessity Required An IP address is a number assigned to a network device (such as a computer) as a permanent address on the network. Computers use the IP address to identify and talk to each other over the network. Choose a proper IP address that is unique and valid in your network environment. Netmask Setting E.g., 255.255.255.0 Factory Default 255.255.255.0 Necessity Required 5-6 NPort W2004 Users Manual Web Console Configuration A netmask is used to group network hosts into subnets. When a packet is sent out over the network, the NPort W2004 will use the netmask to check whether the desired TCP/IP host specified in the packet is on the same subnet as the NPort. If the address is on the same subnet, a connection is established directly between the NPort W2004 and the host. If the host is not on the same subnet, the packet is sent to the Gateway address. Gateway Setting E.g., 192.168.1.1 Factory Default None Necessity Optional A gateway is a network gateway that acts as an entrance to another network. Usually, the computers that control traffic within the network or at the local Internet service provider are gateway nodes. NPort W2004 needs to know the IP address of your networks default gateway computer in order to communicate with the hosts outside the local network environment. For correct gateway IP address information, consult your network administrator. ATTENTION In Dynamic IP environments, the firmware will make 3 requests to the DHCP server every 30 seconds until network settings are assigned by the DHCP server. The Timeout for each try increases from 1 second, to 3 seconds, to 5 seconds. If the DHCP Server is unavailable, the firmware will use the default IP address (192.168.126.254), Netmask, and Gateway for IP settings. WLAN Configuration Network Configuration NPort W2004 supports the IEEE 802.11b wireless network interface. The supported IP configurations are static and dynamic (DHCP). Users can set up the IP configuration via the serial console, or the Web/Telnet consoles through the NPorts Ethernet 5-7 NPort W2004 Users Manual Web Console Configuration interface. For detailed information about configuring IP configuration, IP address, Netmask, and Gateway, see the previous section, Ethernet Configuration. Wireless LAN You may choose from two different WLAN modesInfrastructure Mode and Ad-hoc Mode which are illustrated in the following diagrams. Ad-hoc Mode In the following example, two NPort W2004 devices establish an Ad-hoc peer-to-peer relationship, which means that they communicate with each other directly, without going through an AP
(Access Point). Infrastructure Mode In the following example, the NPort W2004 communicates with the host computer via the AP. The host computer connects to the AP via an Ethernet connection, allowing serial data to be transmitted back and forth between the serial devices and host computer. 5-8 NPort W2004 Users Manual Web Console Configuration SSID Enter the name of the wireless network (SSID) that the W2004 is connected to. Channel Select a radio channel for the wireless network from the pull-down menu. In infrastructure mode, the AP will specify the channel automatically. In Ad-hoc mode, the user must use the pull-down menu to specify the channel. ATTENTION Click on the Wizard to configure the WLAN IP address quickly. Security The wireless network interface supports data encryption (WEP, 64 or 128 bits) and authentication
(Open or Shared authentication). Authentication Select an authentication scheme of Open or Shared from the pull-down menu. WEP Mode By default, WEP Mode is disabled. When WEP Mode is enabled, data packets will be encrypted before send .you can select 64-bit or 128-bit. WEP Key 1/2/3/4 For each of the four WEP Keys, select either ASCII or HEX format, and then enter the appropriate WEP Key. The WEP Keys are used to help prevent data from being stolen as it is transmitted over public networks. The WEP Key setting(s) for the NPort W2004 must be the same as the WEP Key settings for the AP. 5-9 NPort W2004 Users Manual Serial Port Settings Serial port settings are configured by port. Operation Modes Web Console Configuration The Serial Port parameters that appear in the right pane of the browser window when Serial Port Settings # Port 1/2/3/4 # Operation Modes is selected are dependent on which of the four operation modes is selected. We consider each operation mode separately. Real COM Mode Port 1/2/3/4 Max connection Setting 1, 2, 3, 4 Factory Default 1 Necessity Required Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specific host can access this port of the NPort W2004, and the Real COM driver on that host will have full control over the port. Max connection 1 Allows only 1 hosts Real COM driver to open the specific NPort W2004 serial port. Max connection 2 to 4:
Allows 2 to 4 hosts Real COM drivers to open the specific NPort W2004 serial port, at the same time. When multiple hosts Real COM drivers open the serial port at the same time, the COM driver only provides a pure data tunneling without control ability. Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions. The firmware will only send the data back to the driver on the host. Data will be sent first-in-first-out when data comes into the NPort W2004 from the Ethernet interface. 5-10 NPort W2004 Users Manual Web Console Configuration ATTENTION When Max connection is set to 2, 3, or 4, NPort W2004 will use a multi connection application (i.e., 2, 3, or 4 hosts are allowed access to the port at the same time). When using a multi connection application, NPort W2004 will use the serial communication parameters set in the console. All of the hosts connected to that port must use the same serial settings. If one of the hosts opens the COM port with parameters that are different from NPort W2004s console setting, data communication may not work properly. Data Packing Delimiter 1/2 Setting 00 to FF (hex) Factory Default None Necessity Optional Once the NPort W2004 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort W2004s Ethernet port. ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort W2004 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. Force transmit Setting 0 to 65535 ms Factory Default 0 Necessity Optional 0: Disable force transmit timeout. 1 to 65535: Forces the NPort W2004s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame. This parameter defines the time interval during which NPort W2004 fetches the serial data from its internal buffer. If data is incoming through the serial port, NPort W2004 stores the data in the internal buffer. NPort W2004 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no parity. In this case, the total number of bits needed to send a character is 10 bits, and the time required to transfer one character is
( 10 (bits) / 1200 (bits/s) ) * 1000 (ms/s) = 8.3 ms. Therefore, you should set Force transmit to be larger than 8.3 ms, so in this case, it must be greater 5-11 NPort W2004 Users Manual Web Console Configuration than or equal to 10 ms. If you want to send a series of characters in the same packet, the serial device attached to NPort W2004 should send that series of characters during a time interval less than the Force transmit timeout, and the total length of data must be less than or equal to NPort W2004s internal buffer size. The serial communication buffer size for NPort W2004 is 1 KB per port. TCP Server Mode Port 1/2/3/4 Inactivity time Setting 0 to 65535 ms Factory Default 0 ms Necessity Optional 0 ms: TCP connection is not closed due to an idle serial line. 0-65535 ms: NPort W2004 automatically closes the TCP connection if there is no serial data activity for the given time. After the connection is closed, NPort W2004 starts listening for another hosts TCP connection. This parameter defines the maintenance status as Closed or Listen for the TCP connection. The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time. If the Inactivity time is set to 0, the current TCP connection is kept active until a connection close request is received. Although Inactivity time is disabled, the NPort W2004 will check the connection status between the NPort W2004 and remote host by sending keep alive packets periodically. If the remote host does not respond to the packet, NPort W2004 assumes that the connection was closed down unintentionally. NPort W2004 will then force the existing TCP connection to close. 5-12 NPort W2004 Users Manual Web Console Configuration ATTENTION The Inactivity time should be set at least larger than that of Force transmit timeout. To prevent the unintended loss of data due to the session being disconnected, it is highly recommended that this value is set large enough so that the intended data transfer can be completed. Max connection Setting 1, 2, 3, 4 Factory Default 1 Necessity Required Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specific host can access this port of the NPort W2004, and the Real COM driver on that host will have full control over the port. Max connection 1 Allows only 1 hosts Real COM driver to open the specific NPort W2004 serial port. Max connection 2 to 4:
Allows 2 to 4 hosts Real COM drivers to open the specific NPort W2004 serial port, at the same time. When multiple hosts Real COM drivers open the serial port at the same time, the COM driver only provides a pure data tunneling without control ability. Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions. The firmware will only send the data back to the driver on the host. Data will be sent first-in-first-out when data comes into the NPort W2004 from the Ethernet interface. ATTENTION When Max connection is set to 2, 3, or 4, NPort W2004 will use a multi connection application (i.e., 2, 3, or 4 hosts are allowed access to the port at the same time). When using a multi connection application, NPort W2004 will use the serial communication parameters set in the console. All of the hosts connected to that port must use the same serial settings. If one of the hosts opens the COM port with parameters that are different from NPort W2004s console setting, data communication may not work properly. Data Packing Delimiter 1/2 Setting 00 to FF (hex) Factory Default None Necessity Optional Once the NPort W2004 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort W2004s Ethernet port. 5-13 NPort W2004 Users Manual Web Console Configuration ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort W2004 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. Force transmit Setting 0 to 65535 ms Factory Default 0 Necessity Optional 0: Disable force transmit timeout. 1 to 65535: Forces the NPort W2004s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame. This parameter defines the time interval during which NPort W2004 fetches the serial data from its internal buffer. If data is incoming through the serial port, NPort W2004 stores the data in the internal buffer. NPort W2004 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no parity. In this case, the total number of bits needed to send a character is 10 bits, and the time required to transfer one character is
( 10 (bits) / 1200 (bits/s) ) * 1000 (ms/s) = 8.3 ms. Therefore, you should set Force transmit to be larger than 8.3 ms, so in this case, it must be greater than or equal to 10 ms. If you want to send a series of characters in the same packet, the serial device attached to NPort W2004 should send that series of characters during a time interval less than the Force transmit timeout, and the total length of data must be less than or equal to NPort W2004s internal buffer size. The serial communication buffer size for NPort W2004 is 1 KB per port. TCP Server Mode Local TCP Port Setting 1 to 65535 Factory Default 4001 Necessity Required The Local TCP port is the TCP port that NPort W2004 uses to listen to connections, and that other devices must use to contact NPort W2004. To avoid conflicts with well known TCP ports, the default is set to 4001. 5-14 NPort W2004 Users Manual Web Console Configuration Command port Setting 1 to 65535 Factory Default 966 Necessity Optional The Command port is a listen TCP port for IP-Serial Lib commands from the host. In order to prevent a TCP port conflict with other applications, the user can set the Command port to another port if needed. IP-Serial Lib will automatically check the Command Port on NPort W2004 so that the user does not need to configure the program. TCP Client Mode Port 1/2/3/4 TCP alive check time Setting 0 to 99 min Factory Default 7 min Necessity Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort W2004 automatically closes the TCP connection if there is no TCP activity for the given time. After the connection is closed, NPort W2004 starts listening for another hosts TCP connection. Inactivity time Setting 0 to 65535 ms Factory Default 0 ms Necessity Optional 0 ms: TCP connection is not closed due to an idle serial line. 5-15 NPort W2004 Users Manual Web Console Configuration 0-65535 ms: NPort W2004 automatically closes the TCP connection if there is no serial data activity for the given time. After the connection is closed, NPort W2004 starts listening for another hosts TCP connection. This parameter defines the maintenance status as Closed or Listen for the TCP connection. The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time. If the Inactivity time is set to 0, the current TCP connection is kept active until a connection close request is received. Although Inactivity time is disabled, the NPort W2004 will check the connection status between the NPort W2004 and remote host by sending keep alive packets periodically. If the remote host does not respond to the packet, NPort W2004 assumes that the connection was closed down unintentionally. NPort W2004 will then force the existing TCP connection to close. ATTENTION The Inactivity time should be set at least larger than that of Force transmit timeout. To prevent the unintended loss of data due to the session being disconnected, it is highly recommended that this value is set large enough so that the intended data transfer can be completed. ATTENTION Inactivity time is ONLY active when TCP connect on is set to Any character. Data Packing Delimiter 1/2 Setting 00 to FF (hex) Factory Default None Necessity Optional Once the NPort W2004 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort W2004s Ethernet port. ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort W2004 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. 5-16 NPort W2004 Users Manual Web Console Configuration Force transmit Setting 0 to 65535 ms Factory Default 0 Necessity Optional 0: Disable force transmit timeout. 1 to 65535: Forces the NPort W2004s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame. This parameter defines the time interval during which NPort W2004 fetches the serial data from its internal buffer. If data is incoming through the serial port, NPort W2004 stores the data in the internal buffer. NPort W2004 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no parity. In this case, the total number of bits needed to send a character is 10 bits, and the time required to transfer one character is
( 10 (bits) / 1200 (bits/s) ) * 1000 (ms/s) = 8.3 ms. Therefore, you should set Force transmit to be larger than 8.3 ms, so in this case, it must be greater than or equal to 10 ms. If you want to send a series of characters in the same packet, the serial device attached to NPort W2004 should send that series of characters during a time interval less than the Force transmit timeout, and the total length of data must be less than or equal to NPort W2004s internal buffer size. The serial communication buffer size for NPort W2004 is 1 KB per port. TCP Client Mode Destination IP address 1/2/3/4 Setting IP address or Domain Name ATTENTION Factory Default None Necessity Required Inactivity time is ONLY active when TCP connect on is set to Any character. 5-17 NPort W2004 Users Manual Web Console Configuration UDP Mode Data Packing Delimiter 1/2 Setting 00 to FF (hex) Factory Default None Necessity Optional Once the NPort W2004 receives both delimiters through its serial port, it immediately packs all data currently in its buffer and sends it to the NPort W2004s Ethernet port. ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1 KB, the NPort W2004 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. Force transmit Setting 0 to 65535 ms Factory Default 0 Necessity Optional 0: Disable force transmit timeout. 1 to 65535: Forces the NPort W2004s TCP/IP protocol software to try to pack serial data received 5-18 NPort W2004 Users Manual Web Console Configuration during the specified time into the same data frame. This parameter defines the time interval during which NPort W2004 fetches the serial data from its internal buffer. If data is incoming through the serial port, NPort W2004 stores the data in the internal buffer. NPort W2004 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout. The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no parity. In this case, the total number of bits needed to send a character is 10 bits, and the time required to transfer one character is
( 10 (bits) / 1200 (bits/s) ) * 1000 (ms/s) = 8.3 ms. Therefore, you should set Force transmit to be larger than 8.3 ms, so in this case, it must be greater than or equal to 10 ms. If you want to send a series of characters in the same packet, the serial device attached to NPort W2004 should send that series of characters during a time interval less than the Force transmit timeout, and the total length of data must be less than or equal to NPort W2004s internal buffer size. The serial communication buffer size for NPort W2004 is 1 KB per port. UDP Mode Destination IP address 1 Setting IP address range Begin:
E.g. End:
192.168.1.1 192.168.1.10 Destination IP address 2/3/4 Setting IP address range Begin:
E.g. End:
192.168.1.11 192.168.1.20 Factory Default Begin:
End:
Port:
Empty Empty 4001 Factory Default Begin:
Empty Necessity Required Necessity Optional Allows NPort W2004 to connect actively to the remote host whose IP address is set by this parameter. Communication Parameters 5-19 NPort W2004 Users Manual Web Console Configuration Port 1/2/3/4 Port alias Setting 1 to 15 characters
(e.g., PLC-No. 1) Factory Default None Necessity Optional
Port alias is included to allow easy identification of the serial devices that are connected to NPort W2004s serial port. Serial Parameters ATTENTION Check the serial communication parameters in your Serial Devices users manual. You should set up NPort W2004s serial parameters with the same communication parameters used by your serial devices. Baud Rate Setting 50 bps to 460.8 Kbps Factory Default 115.2 Kbps Necessity Required 5-20 NPort W2004 Users Manual Web Console Configuration Data Bits Setting 5, 6, 7, 8 Factory Default 8 Necessity Required When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits. Stop Bits Setting 1, 1.5, 2 Factory Default 1 Stop bits will be set to 1.5 when Data bits is set to 5 bits. Parity Setting None, Odd, Even, Space, Mark Factory Default None Flow Control Setting None, RTS/CTS, XON/XOFF Factory Default RTS/CTS FIFO Setting Enable, Disable Factory Default Enable Necessity Required Necessity Required Necessity Required Necessity Required NPort 2004s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To prevent data loss during communication, disable the FIFO setting when your serial device does not have a FIFO. Interface Model NPort W2004 Factory Default RS-232 Settings RS-232/422/485 Necessity Required Ports 4 System Management Misc. Network Settings Console Settings 5-21
1 | Users Manual Part 2 | Users Manual | 3.08 MiB | January 12 2004 |
NPort W2004 Users Manual Web Console Configuration Use this screen to enable or disable HTTP console, HTTPS console, TELNET console, and SSH console. Accessible IP List NPort W2004 uses an IP address based filtering method to control access to itself. Accessible IP Settings allows you to add or block remote host IP addresses to prevent unauthorized access. Access to NPort W2004 is controlled by IP address. That is, if a hosts IP address is in the accessible IP table, then the host will be allowed to access the NPort W2004. You can set up one of the following cases by setting the parameters accordingly. 5-22 NPort W2004 Users Manual Web Console Configuration
! Only one host with a specific IP Address can access the NPort W2004 Enter the specific IP address (e.g., 192.168.1.1), and enter 255.255.255.255 for Netmask.
! Hosts on the specific subnet can access the NPort W2004 Enter an IP address (e.g., 192.168.1.0), and enter the Netmask (e.g., 255.255.255.0). Note that this type of setting will allow access to all network hosts on a particular subnet.
! Any host can access the NE-4000T Disable this function by un-checking the Enable the accessible IP list checkbox. Refer to the following table for more configration examples. The following Allowable Hosts table gives five configuration examples. Allowable Hosts Any host 192.168.1.120 192.168.1.1 to 192.168.1.254 192.168.0.1 to 192.168.255.254 192.168.1.1 to 192.168.1.126 192.168.1.129 to 192.168.1.254 IP Address blank 192.168.1.120 192.168.1.0 192.168.0.0 192.168.1.0 192.168.1.128 Netmask blank 255.255.255.255 255.255.255.0 255.255.0.0 255.255.255.128 255.255.255.128 TCP Alive Check Time TCP alive check time Setting 0 to 99 min Factory Default 7 min Necessity Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: NPort W2004 automatically closes the TCP connection if there is no TCP activity for the given time. After the connection is closed, NPort W2004 starts listening for another hosts TCP connection. 5-23 NPort W2004 Users Manual Serial Data Logging Web Console Configuration NPort provides the capability to store data logs for all serial ports. The logs will be stored in the system RM. The data will be deleted when NPort is powered off. Due to the systems SDRAM limitation, the memory size of local buffers is fixed. Each serial port is allotted 64 KB to store the ports log file. SNMP Agent To enable the SNMP Agent function, select the enable option, and enter a Community Name (e.g.,
public). Community name Setting 1 to 39 characters
(e.g., Support, 886-89191230
#300) Factory Default public Necessity Optional A community name is a plain-text password mechanism that is used to authenticate weakly queries to agents of managed network devices. Contact Setting Factory Default Necessity 5-24 NPort W2004 Users Manual Web Console Configuration 1 to 39 characters
(e.g., Support, 886-89191230
#300) None Optional The SNMP contact information usually includes an emergency contact name and telephone or pager number. Location Setting 1 to 39 characters
(e.g., Floor 1, Office No. 2) Factory Default None Necessity Optional Specify the location string for SNMP agents such as NPort W2004. This string is usually set to the street address where the NPort W2004 is physically located. Auto Warning Settings Event Settings System Event Cold start This refers to starting the system from power off (contrast this with warm start). When performing a cold start, NPort W2004 will automatically issue an Auto warning message by e-mail, or send an SNMP trap after booting up. Warm start This refers to restarting the computer without turning the power off. When performing a warm 5-25 NPort W2004 Users Manual Web Console Configuration start, NPort W2004 will automatically send an e-mail, or send an SNMP trap after rebooting. Authentication Failure The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, NPort W2004 will immediately send an e-mail or send an SNMP trap. IP address changed The user has changed NPort W2004s IP address. When the IP address changes, NPort W2004 will send an e-mail with the new IP address before NPort W2004 reboots. If the NPort W2004 is unable to send an e-mail message to the mail server within 15 seconds, NPort W2004 will reboot anyway, and abort the e-mail auto warning. Password changed The user has changed NPort W2004s password. When the password changes, NPort W2004 will send an e-mail with the password changed notice before NPort W2004 reboots. If the NPort W2004 is unable to send an e-mail message to the mail server within 15 seconds, NPort W2004 will reboot anyway, and abort the e-mail auto warning. Serial Port Event : DCD Changed The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection status has changed. For example, a DCD change to high also means Connected between local modem and remote modem. If the DCD signal changes to low, it also means that the connection line is down. When the DCD changes, NPort W2004 will immediately send an e-mail or send an SNMP trap. Serial Port Event : DSR Changed The DSR (Data Set Ready) signal has changed, also indicating that the data communication equipments power is off. For example, a DSR change to high also means that the DCE is powered ON. If the DSR signal changes to low, it also means that the DCE is powered off. When the DSR changes, NPort W2004 will immediately send an e-mail or send an SNMP trap. Checkbox Items Local Log Setting Enable, Disable Factory Default Disable Necessity Optional This feature helps the administrator manage how the NPort W2004 logs system events when enabled eventssuch as Cold start, Warm start, Authentication failure, etc.occur. To configure this feature, click on the Event Type Local Log checkbox. Mail Setting Enable, Disable Factory Default Disable Necessity Optional This feature helps the administrator manage how the NPort W2004 sends e-mail to pre-defined e-mail boxes when the enabled eventssuch as Cold start, Warm start, Authentication failure, etc.occur. To configure this feature, click on the Event Type Mail checkbox. Trap Setting Enable, Disable Factory Default Disable Necessity Optional 5-26 NPort W2004 Users Manual Web Console Configuration This feature helps the administrator manage how the NPort W2004 sends SNMP Trap to a pre-defined SNMP Trap server when the enabled eventssuch as Cold start, Warm start, Authentication failure, etc.occur. To configure this feature, click on the Event Type Trap checkbox. E-mail Alert Mail Server Settings Mail server (SMTP) Setting IP Address or Domain Name User name Setting 1 to 15 characters Password Setting 1 to 15 characters From E-mail address Setting 1 to 63 characters Alert Mailing List E-mail address 1/2/3/4 Setting 1 to 63 characters Factory Default None Factory Default None Factory Default None Factory Default None Factory Default None Necessity Optional Necessity Optional Necessity Optional Necessity Optional Necessity Optional 5-27 NPort W2004 Users Manual Web Console Configuration ATTENTION Consult your Network Administrator or ISP for the proper mail server settings. The Auto warning function may not work properly if it is not configured correctly. NPort W2004 SMTP AUTH supports LOGIN, PLAIN, CRAM-MD5 (RFC 2554). SNMP Trap SNMP trap receiver IP (or domain name) Setting IP address or Domain Name Factory Default None Necessity Optional 5-28 NPort W2004 Users Manual Web Console Configuration System Status WLAN Status The WLAN Status page lists Mode, SSID, Band, Channel, Link Status, Signal Strength, Connection Speed, WEP Mode, IP Configuration, IP Address, and Netmask, as shown in the following figure. Serial to Network Connections The Serial to Network Connections page lists the operation modes and IP addresses associated with each of the wireless device servers serial ports. 5-29 NPort W2004 Users Manual Web Console Configuration Serial Port Status The Serial Port Status page lists serial transmission stats for each of the wireless device servers serial ports. Serial Port Settings The Serial Port Settings page lists the serial transmission settings for each of the four ports. Serial Data Log This Text box is enabled only when Data logging is enabled. The data log contents are displayed in ASCII mode or HEX mode. Use the Select all button to select the entire log; you can then copy and paste the contents into a text file. The Clear log and Refresh buttons are used to clear the log, and refresh the log contents, respectively. 5-30 NPort W2004 Users Manual Network Connections Web Console Configuration The Network Connections page displays the current status of the network connection. System Log This window displays the System Log. Use the Select all button to select the entire log; you can then copy and paste the contents into a text file. The Clear log and Refresh buttons are used to clear the log, and refresh the log contents, respectively. 5-31 NPort W2004 Users Manual Change Password Firmware Upgrade Click on Firmware Upgrade to upgrade the firmware. Web Console Configuration Select the correct firmware file, and then click on Submit to load the new firmware into the NPort W2004s memory. Configuration Import Select the a configuration file, and then click on Submit to load the configuration settings into the NPort W2004. Configuration Export Click on the Download button, and then select the file that you would like to export the current configuration to. 5-32 NPort W2004 Users Manual Web Console Configuration Configuration Export Use this page to reset the NPort W2004s settings to the factory default values. Be aware that previous settings will be lost. Choose one of the two optionsReset to factory default
(excluding IP configuration) or Reset to factory defaultand then click on Submit. Choose the first option to retain the current IP address, Netmask, and Gateway address. Change Password To change the password for the NPort W2004, input the Old password, New password, and then retype the new password in the Retype password input box. To erase the password, simply leave all three text input boxes blank, and then click on Submit. 5-33 NPort W2004 Users Manual Web Console Configuration ATTENTION If you forget the password, the ONLY way to configure NPort W2004 is by using the Reset button on NPort W2004s casing to Load Factory Default. Restart Ports Select the ports you would like to restart, and then click on the Submit button to restart the ports. Restart System Click on Submit to reboot the NPort W2004.. 5-34 Chapter 6 66 Installing and Configuring the Software This following topics are covered in this chapter:
! Overview
Installing NPort COM Driver Intalling NPort Search Utility
! Configuring NPort COM Driver
! Configuring NPort Search Utility
! Real TTY and Fixed TTY Installation
! Upgrading the Firmware NPort W2004 Users Manual Installing and Configuring the Software Overview The Documentation & Software CD included with your NPort W2004 is designed to make the installation and configuration procedure easy and straightforward. This auto-run CD includes the NPort COM Driver (for COM mapping), NPort Search Utility (to broadcast search for all NPort W2004 accessible over the network), Users Manual, and firmware upgrade utility. Installing NPort COM Driver 1. Click on the INSTALL COM Driver button in the NPort Installation CD auto-run window to install the NPort W2000 Series COM Driver. 2. Once the installation program starts running, click on Yes to proceed. 3. Click on Next when the Welcome window opens to proceed with the installation. 6-2 NPort W2004 Users Manual Installing and Configuring the Software 4. Click on Next to install program files in the default directory, or use the folder menu to select an alternative location. 6-3 NPort W2004 Users Manual Installing and Configuring the Software 5. Click on Next to install the programs shortcuts in the NPort Windows Driver Manager Start Menu folder. 6. Click on Install to proceed with the installation. 7. The Installing window will report the progress of the installation. 8. Click on Finish to complete the installation of the NPort W2004 COM Mapping Utility. 6-4 NPort W2004 Users Manual Installing and Configuring the Software Installing NPort Search Utility 1. Click on the INSTALL UTILITY button in the NPort Installation CD auto-run window to install the NPort Search Utility. 6-5 NPort W2004 Users Manual Installing and Configuring the Software 2. Once the program starts running, click on Yes to proceed. 3. Click on Next when the Welcome window opens to proceed with the installation. 6-6 NPort W2004 Users Manual Installing and Configuring the Software 4. Click on Next to install program files in the default directory, or use the folder menu to select an alternative location. 6-7 NPort W2004 Users Manual Installing and Configuring the Software 5. Click on Next to install the programs shortcuts in the NPort Search Utility Start Menu folder. 6. Click on Install to proceed with the installation. 7. The Installing window will report the progress of the installation. 8. Click on Finish to complete the installation of the NPort W2004 Search Utility. 6-8 NPort W2004 Users Manual Installing and Configuring the Software Configuring NPort COM Driver The NPort COM Driver utility installs Real COM drivers that work under Windows 98/ME/2000/XP/2003. After you install NPort COM Driver, you can set up the NPort W2004s serial ports as remote COM ports for your PC host. Use the following steps to map the COM ports:
1. Click on Start # Nport Windows Driver Manager # NPort COM Mapping Utility to start the COM mapping utility. 6-9 NPort W2004 Users Manual Installing and Configuring the Software 2. Click on the Add icon. 3. Click on Rescan to search for NPort device servers, select the server you would like to map COM ports to, and then click on OK. 6-10 NPort W2004 Users Manual Installing and Configuring the Software 4. Alternatively, you can select Input Manually and then input the NPort IP Address, 1st Data Port, 1st Command Port, and Total Ports for the NPort W2004 that you would like to map COM ports to. Click on OK to proceed to the next step. 5. Click on Yes to activate the COM ports at this time, or click on No to activate the COM ports later. Activating the COM ports saves the information in the host system registry. The host computer will not have the ability to use the COM port until you click on the Apply icon. 6-11 NPort W2004 Users Manual Installing and Configuring the Software 6. The display text corresponding to NPorts whose ports are activated will change from blue to black. 7. To re-configure the settings for a particular NPort, click on the row corresponding to that NPort to highlight it, and then click on the Setting icon. 6-12 NPort W2004 Users Manual Installing and Configuring the Software 8. In the Basic Setting panel, use the COM Number drop-down list to select a COM number for the NPorts first serial port. Check mark the Auto Enumerating COM Number for Selected Ports checkbox to automatically assign the next available COM number to the second serial port. Note that ports that are in use will be labeled accordingly. Click on the Advanced Setting tab to modify Tx Mode, FIFO, and Flash Flush. Tx Mode Hi-performance mode is the default for Tx mode. When the driver finishes sending data to the NPort W2004, the driver will issue a Tx Empty response to the program. Under classical mode, the driver will not notify the users program that Tx transmission is finished until all Tx data has been sent out from the NPort W2004. This ODE will cause 6-13 NPort W2004 Users Manual Installing and Configuring the Software lower throughput. Classical mode is recommended if you want to ensure that all data is sent out before further processing. FIFO If the FIFO is Disabled, NPort W2004 will transmit one byte each time the Tx FIFO becomes empty, and an Rx interrupt will be generated for each incoming byte. This will result in a faster response and lower throughput. If you want to use XON/XOFF flow control, we recommend setting the FIFO to Disable. Fast Flush (only flushes the local buffer) a. We have added one optional Fast Flush function to Moxas new NPort Real COM driver. b. For some applications, the users program will use the Win32 PurgeComm() function before it reads or writes data. With our design, after the program uses this Purge Comm() function, the NPort driver will keep querying NPorts firmware several times to make sure no data is queued in the NPort firmware buffer, rather than just flushing the local buffer. This kind of design is used to satisfy some special considerations. However, it might take more time (about several hundred milliseconds) than a native COM1, because it needs to work via Ethernet. Thats why the native COM ports on the motherboard can work fast with this function call, but NPort requires much more time. In order to accommodate other applications that require a faster response time, the new NPort driver implements a new Fast Flush option. Note that by default, this function is disabled. c. To begin with, make sure there are some PurgeComm() functions being used in your application program. In this kind of situation, you might find that your NPort exhibits a much poorer operation performance than when using the native COM1 port. Once you have enabled the Fast Flush function, you can check to see if there has been an improvement in performance. d. By default, the optional Fast Flush function is disabled. If you would like to enable this function, double click on the COM ports that are mapped to the NPort, and then select the Fast Flush checkbox. You should find that when Fast Flush is enabled, the NPort driver will work faster with PurgeComm(). 6-14 NPort W2004 Users Manual Installing and Configuring the Software 9. The Serial Parameter settings shown in the following figure are the default settings when the NPort W2004 is powered on. However, the program can redefine the serial parameters to different values after the program opens the port via Win 32 API. 6-15 NPort W2004 Users Manual Installing and Configuring the Software 10. To save the configuration to a text file, select Export COM Mapping. You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host. 6-16 NPort W2004 Users Manual Installing and Configuring the Software Configuring NPort Search Utility The Broadcast Search function is used to locate all NPort W2004s that are connected to the same LAN as your computer. After locating an NPort W2004, you will be able to change the IP address. Since the Broadcast Search function searches by MAC address and not IP address, all NPort W2004s connected to the LAN will be located, regardless of whether or not they are part of the same subnet as the host. 1. Open the NPort Search Utility and then click on the Search icon. 2. The Searching window indicates the progress of the search. 3. When the search is complete, the NPort W2004 units that were located will be displayed in the NPort Search Utility window. 6-17 NPort W2004 Users Manual Installing and Configuring the Software 4. Click on the Assign IP icon to change the IP address. 6-18
NPort W2004 Users Manual Installing and Configuring the Software Real TTY and Fixed TTY Installation Installing the Real TTY driver Procedure To map an NPort serial port to the hosts tty port, you need to:
1. Set up NPort Make sure the IP configuration is ok and you can access the NPort (ping, telnet...) successfully, and then configure the NPort serial port to Real COM Mode. Install driver files on the host Refer to Driver Files Installation below for details. 2. 3. Map the NPort serial port to the hosts tty port Refer to Mapping TTY Ports below for details. Hardware Installation Before proceeding with the software installation, make sure you have completed the hardware installation, as illustrated in the users manual. The default IP address for NPort Server is 192.168.127.254. NOTE After installing the hardware, you MUST configure the NPort operating mode to Real COM Mode. Driver Files Installation a. Get the driver file from the product CD-ROM or Moxa website. b. Log in to the console as a super user (root). c. Execute cd / to go to the root directory. d. Copy the driver file npreal2xx.tgz to the / directory. e. Execute tar xvfz npreal2xx.tgz to copy all files into the system. f. Execute /tmp/moxa/mxinst. NOTE For RedHat AS/ES/WS and Fedora Core1, extra argument is needed: # /tmp/moxa/mxinst SP1 g. The shell script will install the driver files automatically. After installing the driver, you will be able to see several files in the /usr/lib/npreal2/driver folder, including
> mxaddsvr
> mxdelsvr
> mxloadsvr
> mxmknod
> mxrmnod
(Add Server, mapping tty port)
(Delete Server, un-mapping tty port)
(Reload Server)
(Create device node/tty port)
(Remove device node/tty port) 6-19 NPort W2004 Users Manual Installing and Configuring the Software
> mxuninst
(Remove tty port and driver files) At this point, you will be ready to map the NPort serial port to the system tty port. See Mapping TTY Ports below for detailed instructions. Mapping TTY Ports Before mapping tty ports, you must set the operation mode of your NPort to Real Com Mode. We provide two ways to map tty ports. Mapping tty ports automatically After logging in as a super user, enter the directory /usr/lib/npreal2/driver and then execute mxaddsvr to map the target NPort serial port to the host tty ports. The syntax of mxaddsvr is:
mxaddsvr [NPort IP Address] [Total Ports] ([Data port] [Cmd port]) Example 1:
# cd /usr/lib/npreal2/driver
# ./mxaddsvr 192.168.3.4 16 Example2:
# cd /usr/lib/npreal2/driver
# ./mxaddsvr 192.168.3.4 16 4001 966 In Example 1, 16 tty ports will be added, all with IP 192.168.3.4, but with data ports equal to (950, 951, , 965), and command ports equal to (966, 967, 968, , 981). In example2, 16 tty ports will be added, all with IP 192.168.3.4, but with data ports equal to (4001, 4002, , 4016), and command ports equal to (966, 967, 968, , 981). The following actions will be performed:
> Modify the "npreal2d.cf"
> Create tty ports in directory "/dev" with major & minor number configured in npreal2d.cf.
> Stop and then restart the driver. Remove Mapped TTY ports As with the Mapping TTY Ports task, we provide two ways to remove mapped tty ports:
Remove the mapped tty ports automatically After logging in as root, enter the directory /usr/lib/npreal2/driver and then execute mxdelsvr to delete a server. The syntax of mxdelsvr is:
mxdelsvr [IP]
Example:
# cd /usr/lib/npreal2/driver
# ./mxdelsvr 192.168.3.4 If you dont provide the IP address in the command line, the program will list the installed servers and total ports on screen, so that you can only choose the index of the installed server list to delete. The following actions will be performed:
> Modify the npreal2d.cf 6-20 NPort W2004 Users Manual Installing and Configuring the Software
> Remove the relevant tty ports in directory /dev
> Stop and then restart the driver. Driver Files Removal Driver Removal will remove all driver files, mapped tty ports, and unload the driver. To do this, you only need to enter the directory /usr/lib/npreal2/driver, and then execute mxuninst to uninstall the driver. This program will perform the following actions:
> Unload the driver.
> Delete all files and directories in "/usr/lib/npreal2"
> Delete directory "/usr/lib/npreal2".
> Modify the system initializing script file. Installing the fixed TTY driver Installation and Configuration step 1 :
login to UNIX and create a directory for MOXA TTY, for instance, /usr/etc.
# mkdir /usr/etc
# cd /usr/etc step 2 :
Extract source code from tar-file :
Type "tar xvf moxattyd.tar". step 3 :
step 4 :
After extract, you can find the following files :
README moxattyd.c --> source program moxattyd.cf Makefile
--> empty configuration file
--> makefile
--> this file
# make linux Compile and Link :
For SCO UNIX:
# make sco For Linux:
For UnixWare 7:
# make svr5 For UnixWare 2.1.x, SVR4.2:
For IBM AIX:
For HP-UNIX:
For SunOS 5.8:
For QNX6:
# make hpunix
# make svr42
# make qnx6
# make sun
# make aix Modify configuration :
The configuration of moxattyd program is defined on
"moxattyd.cf" file at the same directory where contains 6-21 NPort W2004 Users Manual Installing and Configuring the Software program moxattyd. User can use vi or any edit to modify it. Its a text file. For more configuration information, please take at moxattyd.cf file. We put detail decription on it. a look
Please note that the "Device Name" is depended on OS. See "E. Device Naming Rule" for more information.
step 5 :
finish :
Add program moxattyd into /etc/inittab and any tty name you configued at moxattyd.cf. eg. for Linux:
You have finished the installation and configuration of MOXA TTY. ts:2:respawn:/usr/etc/moxattyd p1:345:respawn:/etc/mingetty ttyp1 p2:345:respawn:/etc/mingetty ttyp2 Start moxattyd program Run "init q" or reboot your UNIX. Add additional server Step 1 Step 2 Step 3 Modify "moxattyd.cf" file to add additional server.
User can use vi or any edit to modify it. Its a text file. For more configuration information, please take at moxattyd.cf file. We put detail decription on it. a look Find the proccess id (PID) of program "moxattyd".
# ps -ef | grep moxattyd Update configuration of moxattyd program.
# kill -USR1 PID
(ex. if "moxattyd" PID = 404, "kill -USR1 404") finish :
You have finished to add additional server. 6-22 AA Appendix ASNMP Agents with MIB II & RS-232 Like Groups NPort has built-in SNMP (Simple Network Management Protocol) agent software that supports SNMP Trap, RFC1317 RS-232 like groups and RFC 1213 MIB-II. The following table lists the standard MIB-II groups, as well as the variable implementation for NPort . RFC1213 MIB-II supported SNMP variables:
System MIB Interfaces MIB ICMP MIB IP MIB SysDescr SysObjectID SysUpTime SysContact SysName SysLocation SysServices itNumber ifIndex ifDescr ifType ifMtu ifSpeed ifPhysAddress ifAdminStatus ifOperStatus ifLastChange ifInOctets ifInUcastPkts ifInNUcastPkts ifInDiscards ifInErrors ipForwarding ipDefaultTTL ipInreceives ipInHdrErrors ipInAddrErrors ipForwDatagrams ipInUnknownProtos ipInDiscards ipInDelivers ipOutRequests ipOutDiscards ipOutNoRoutes ipReasmTimeout ipReasmReqds ipReasmOKs IcmpInMsgs IcmpInErrors IcmpInDestUnreachs IcmpInTimeExcds IcmpInParmProbs IcmpInSrcQuenchs IcmpInRedirects IcmpInEchos IcmpInEchoReps IcmpInTimestamps IcmpTimestampReps IcmpInAddrMasks IcmpOutMsgs IcmpOutErrors IcmpOutDestUnreachs NPort W2004 Users Manual SNMP Agents with MIB II & RS-232 Like Groups System MIB Interfaces MIB IP MIB ICMP MIB IcmpOutTimeExcds IcmpOutParmProbs IcmpOutSrcQuenchs IcmpOutRedirects IcmpOutEchos IcmpOutEchoReps IcmpOutTimestamps IcmpOutTimestampReps IcmpOutAddrMasks IcmpOutAddrMaskReps ifInUnknownProtos ipReasmFails ifOutOctets ifOutUcastPkts ifOutNUcastPkts ifOutDiscards ifOutErrors ifOutQLen ifSpecific ipFragOKs ipFragFails ipFragCreates ipAdEntAddr ipAdEntIfIndex ipAdEntNetMask ipAdEntBcastAddr ipAdEntReasmMaxSize IpNetToMediaIfIndex IpNetToMediaPhysAddress IpNetToMediaNetAddress IpNetToMediaType IpRoutingDiscards SysServices UDP MIB TCP MIB SNMP MIB UdpInDatagrams UdpNoPorts UdpInErrors UdpOutDatagrams UdpLocalAddress UdpLocalPort Address Translation MIB AtIfIndex AtPhysAddress AtNetAddress tcpRtoAlgorithm tcpRtoMin tcpRtoMax tcpMaxConn tcpActiveOpens tcpPassiveOpens tcpAttempFails tcpEstabResets tcpCurrEstab tcpInSegs tcpOutSegs snmpInPkts snmpOutPkts snmpInBadVersions snmpInBadCommunityNames snmpInASNParseErrs snmpInTooBigs snmpInNoSuchNames snmpInBadValues snmpInReadOnlys snmpInGenErrs snmpInTotalReqVars A-2 NPort W2004 Users Manual SNMP Agents with MIB II & RS-232 Like Groups Address Translation MIB AtNetAddress TCP MIB tcpRetransSegs tcpConnState tcpConnLocalAddress tcpConnLocalPort tcpConnRemAddress tcpConnRemPort tcpInErrs tcpOutRsts SNMP MIB snmpInTotalSetVars snmpInGetRequests snmpInGetNexts snmpInSetRequests snmpInGetResponses snmpInTraps snmpOutTooBigs snmpOutNoSuchNames snmpOutBadValues snmpOutGenErrs snmpOutGetRequests snmpOutGetNexts snmpOutSetRequests snmpOutGetResponses snmpOutTraps snmpEnableAuthenTraps RFC1317: RS-232 MIB objects Generic RS-232-like Group RS-232-like General Port Table rs232Number The Input Signal Table rs232InSigTable rs232InSigEntry rs232InSigPortIndex rs232InSigName rs232InSigState rs232PortTable rs232PortEntry rs232PortIndex rs232PortType rs232PortInSigNumber rs232PortOutSigNumber rs232PortInSpeed rs232PortOutSpeed RS-232-like Asynchronous Port Group rs232AsyncPortTable rs232AsyncPortEntry rs232AsyncPortIndex rs232AsyncPortBits rs232AsyncPortStopBits rs232AsyncPortParity The Output Signal Table rs232OutSigTable rs232OutSigEntry rs232OutSigPortIndex rs232OutSigName rs232OutSigState A-3 BB Appendix BWell Known Port Numbers This appendix is for your reference. Listed below are Well Known Port Numbers that may cause network problems if you configure NE-4000T for the same port. Refer to RFC 1700 for Well Known Port Numbers or refer to the following introduction from IANA. The port numbers are divided into three ranges: the Well Known Ports, the Registered Ports, and the Dynamic and/or Private Ports.
The Well Known Ports are assigned by IANA, and on most systems, can only be used by system processes or by programs executed by privileged users. The following table shows famous port numbers among the well-known port numbers. For more details, please visit the IANA website at http://www.iana.org/assignments/port-numbers The Well Known Ports range from 0 through 1023. The Registered Ports range from 1024 through 49151. The Dynamic and/or Private Ports range from 49152 through 65535. TCP Socket Application Service 0 1 2 7 9 11 13 15 20 21 23 25 37 42 reserved TCP Port Service Multiplexor Management Utility Echo Discard Active Users (systat) Daytime Netstat FTP data port FTP CONTROL port Telnet SMTP (Simple Mail Transfer Protocol) Time (Time Server) Host name server (names server) NPort W2004 Users Manual Well Known Port Numbers TCP Socket Application Service 43 49 53 79 80 119 123 213 160 223 Whois (nickname)
(Login Host Protocol) (Login) Domain Name Server (domain) Finger protocol (Finger) World Wibe Web HTTP Netword news Transfer Protocol (NNTP) Network Time Protocol IPX Reserved for future use UDP Socket Application Service 0 2 7 9 11 13 35 39 42 43 49 53 69 70 79 80 107 111 119 123 161 162 213 reserved Management Utility Echo Discard Active Users (systat) Daytime Any private printer server Resource Location Protocol Host name server (names server) Whois (nickname)
(Login Host Protocol) (Login) Domain Name Server (domain) Trivial Transfer Protocol (TETP) Gopler Protocol Finger Protocol World Wide Web HTTP Remote Telnet Service Sun Remote Procedure Call (Sunrpc) Network news Tcanster Protocol (NNTP) Network Time protocol (nnp) SNMP (Simple Network Mail Protocol) SNMP Traps IPX (Used for IP Tunneling) B-2 CC Appendix CService Information This appendix shows you how to contact Moxa for information about this and other products, and how to report problems. In this appendix, we cover the following topics.
! MOXA Internet Services
! Problem Report Form
! Product Return Procedure NPort W2004 Users Manual Service Information MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and users manual updates. The following services are provided E-mail for technical support................................support@moxa.com.tw Moxa Group website for product information, driver downloads, documentation, and more:
.............................http://www.moxa.com C-2 NPort W2004 Users Manual Service Information Problem Report Form MOXA NPort W2004 Customer name:
Company:
Tel:
Email:
1. Moxa Product: $ NPort W2004 2. Serial Number: _________________ Problem Description: Please describe the symptoms of the problem as clearly as possible, including any error messages you see. A clearly written description of the problem will allow us to reproduce the symptoms, and expedite the repair of your product. Fax:
Date:
C-3 NPort W2004 Users Manual Service Information Product Return Procedure For product repair, exchange, or refund, the customer must:
% Provide evidence of original purchase.
% Obtain a Product Return Agreement (PRA) from the sales representative or dealer.
% Fill out the Problem Report Form (PRF). Include as much detail as possible for a shorter product repair time.
% Carefully pack the product in an anti-static package, and send it, pre-paid, to the dealer. The PRA should be visible on the outside of the package, and include a description of the problem, along with the return address and telephone number of a technical contact. C-4 DD Appendix DFederal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.
Moxa declares that NPort W2004 is limited to CH1-CH11 by specified firmware when controlled in the USA. IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. INFORMATION TO USER:
The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-12-01 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-12-01
|
||||
1 | Applicant's complete, legal business name |
Moxa Inc.
|
||||
1 | FCC Registration Number (FRN) |
0011650785
|
||||
1 | Physical Address |
4F, No.135, Lane 235, BAOQIAO Rd. XINDIAN DIST.
|
||||
1 |
NEW TAIPEI CITY, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@americantcb.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
SLE
|
||||
1 | Equipment Product Code |
W2004
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
O******** C********
|
||||
1 | Title |
Assistant Manager
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
o******@moxa.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Advance Data Technology Corp.
|
||||
1 | Name |
E**** W****
|
||||
1 | Physical Address |
No.19, Hwa Ya 2nd Rd.
|
||||
1 |
Kueishan Taoyuan, 333
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
+886-******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
e******@adt.com.tw
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Serial Device Server | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is Conducted. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Advance Data Technology Corporation
|
||||
1 | Name |
S******** C****
|
||||
1 | Telephone Number |
88626********
|
||||
1 | Fax Number |
88626********
|
||||
1 |
s******@adt.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 17 | 2412.00000000 | 2462.00000000 | 0.0640000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC