Table of Content Package content Tools required Prior to installation Cylinder & unit Installation 1. Cylinder Installation 1.1 1.2 1.3 1.4 1.5 Magnet fitting 1.6 2. ENTR description 2.1 2.2 2.3 ON/OFF switch ENTR description Indications Cylinder to unit assembly (optional) 2.3.1 Switching the ENTR ON 2.3.2 Switching the ENTR OFF 2.3.3 Low battery indication Initiating the lock 2.4 2.5 Default PIN code 3. Operation 3.1 Changing PIN code 3.2 Door configuration 3.3 Pairing remote control 3.4 Deleting remote control 3.5 Setting the sound signal Setting locking mode 3.6 Operated by knob 3.7 3.8 Operated by slide buttons 5 5 5 6 6 7 7 9 9 9 10 10 10 10 11 11 12 12 13 14 15 16 17 18 18 ii ENTR Dead Bolt User Manual 4. Touchpad Reader Changing PIN code 4.1 4.2 Battery replacement 4.2.1 Low battery indication Pairing Touchpad Reader Touchpad Reader master PIN code 5. Touchpad Reader operation 5.1 Operation 5.2 5.3 5.4 Menu mode 5.5 Adding personal user code 5.6 Open door 5.7 Lock door 5.8 Delete personal user code 5.9 Delete all personal user codes 5.10 Factory reset 6. Fingerprint Reader 6.1 Mounting the Fingerprint Reader 6.2 6.3 Battery replacement Initial configuration 6.3.1 Adjust Date & Time 6.4 Pairing fingerprint reader 6.4.1 Add master 6.4.2 6.4.3 Set finger Set PIN code Unlock the door 6.5 ENTR Dead Bolt User Manual 19 19 19 19 20 20 20 22 22 22 23 23 23 23 24 25 25 25 25 25 26 27 27 27 28 iii Lock Door Low-battery Indication Setting Menu Add User 6.6 6.7 6.8 6.9 6.10 Delete User 6.11 Enable/Disable User 6.12 Delete all Users 6.13 Add Time Schedule 6.14 Edit Time Schedule 6.15 Volume Control 6.16 Double Security 6.17 Factory Reset 7. Smartphone App 7.1 7.2 8. Remote Control Battery Change Battery Removal 8.1 8.2 Battery Insertion 9. Sabbath Mode 10. Troubleshooting 10.1 Limitations and External Influences 10.2 Cases Limited warranty Federal Communications Commission (FCC) Statement App Installation Pairing Smartphone 31 31 31 32 33 33 34 34 35 35 36 36 37 37 38 39 39 40 41 42 42 42 45 48 4 iv ENTR Dead Bolt User Manual 1. Cylinder Installation 1.1 Package content 1 2 3 4 9 Base plate & Knob Electrical unit Mounting screw Panel screw Decorative spacer 5 6 7 8 Battery charger Magnet Inside drive adaptor Mounting screws 1.2 Tools required 2mm Allen key 3mm Allen key 5/32" Allen key Small flat screwdriver Note: Do not use power tools or any excessive force to assemble ENTR parts. ENTR Dead Bolt User Manual 5 1.3 Prior to installation Warning: Do not attempt to operate the unit until assembled into the door Remove knob screw using 1/16" Allen key and take the knob out. Use a flat screwdriver to remove the cover. Remove both Allen screws entirely and remove internal mechanism. Note: While removing the internal mechanism secure the outside cylinder from falling. Consider using masking tape or similar. Knob Knob screw Cover 1.4 Unit installation Prior to installation check bolt locking direction. Verify that the bolt is in open position (bolt inside the door, unlocked). Rotate adaptor tail piece opposite to the bolt locking direction until stopped. Verify that the wide teeth is pointing up. If not rotate the external ring until the wide teeth will point up. Wide teeth Bolt locking direction Rotate adaptor tail piece opposite to the bolt locking direction 6 ENTR Dead Bolt User Manual Place the Inside drive adaptor and tighten the screws. Do not over tighten the screw or use power tools. Adaptor Place decorative spacer over the Inside drive adaptor Assemble base plate (top housing & knob). Tighten cylinder mounting screw. Mounting screw Decorative spacer Base plate Note: In case the gear and the projecting rectangle are not aligned the unit will not be engaged to the knob. Knob back view Knob back view Adaptor Adaptor ENTR Dead Bolt User Manual 7 Carefully connect data cable plug. Assemble electrical unit panel (battery housing). attache to base plate (1) and push down (2). Tighten electrical unit panel screw. Electrical unit 1 Data cable plug Panel screw 2 1.5 Magnet fitting Magnet Fitting:
Position the magnet on the frame. moldings, as close as possible to the lock. The top point of the magnet should be Align with the lower point of the slider
(see illustration). Note: The magnet area on frame molding should be clean and free from dust, peeling paint etc. Use alcohol if required. Wait until completely dry prior to sticking. Frame molding Magnet Slider 8 ENTR Dead Bolt User Manual 2. ENTR description 2.1 ENTR description ON/OFF switch Touchpad Indications Knob 2.2 Indications Mute (Green) Manual Mode (Green) OK (Green) Door not closed (Red) Battery status (Green/Red) Error (Red) ENTR Dead Bolt User Manual 9 2.3 ON/OFF switch Turning the ENTR lock ON or OFF. 2.3.1 Switching the ENTR ON Before turning ENTR ON, verify that the door is shut. Move the switch to the ON position. Make sure that the knob is in the zero position
(see illustration). Function and numeric buttons will all blink once. Hazard beep sound will be emitted and error indication will blink once. ENTR is now in operating mode. Note:
After turning ENTR ON, avoid touching the front panel until beep sound ends. After turning ENTR ON, the door will be shut but not locked. OFF ON Zero position 2.3.2 Switching the ENTR OFF Move the switch to OFF position. 2.3.3 Low battery indication Battery red signal rapidly blinking and 2 long beeps will be emitted during every lock/unlock action, indicating that the battery is low and needs to be charged. 10 ENTR Dead Bolt User Manual 2.4 Initialization of the Lock Initiate the lock by touching the screen with the palm of your hand or fingers for 3 seconds. Programing buttons and battery status indication light will illuminate for 15 seconds, waiting for user's action. After 15 seconds of inactivity, ENTR will idle. 2.5 Default PIN Code The lock's default factory PIN code is: 1 2 3 4 5 #
Please note:
Default PIN code must be changed before starting the configuration process. The PIN code must consist of 4-10 digits using numbers 1 through 5 in any sequence. Only the Code and Mute functions will operate until the default PIN code is changed ENTR Dead Bolt User Manual 11 3. Operation 3.1 Changing PIN code Warning: Do not attempt to operate the unit until assembled on the door. 1 Touch screen with palm or fingers for 3 seconds to active. 2 Press [Code]
Numeric buttons illuminated. 3 Type [Default PIN code]
(1 2 3 4 5)
[#]
4
[OK] indication blinks once, 1 long beep emitted. Illuminated buttons turn off. 5 Numeric buttons illuminated Enter
[New PIN code] (4-10 digits)
[#]
For example: 1231234#
6
[OK] indication blinks once. 1 long beep emitted. Illuminated buttons turns off. 7 Numeric buttons illuminated Reenter
[New PIN code]
[#]
For example: 1231234#
PIN codes match
[OK] indication illuminated. 2 short beep emitted. New PIN code is set. PIN Code doesn't match
[Error] indication illuminated. 2 long Beeps emitted for 1 second. ENTR goes to menu mode. Start the process from stage 1. 12 ENTR Dead Bolt User Manual 3.2 Door Configuration The door configuration process sets your lock and door preferences. This process should be done after successful installation of the lock. It will take 15-20 seconds to complete. 1 Important: Verify that the door is shut and no key is inserted into the cylinder during configuration steps. 2 Touch screen with palm or fingers for 3 seconds to active. 3 Press [Cfg]
4 Numeric buttons illuminated, Type [PIN code]
1 long beep emitted.
[#]
5 Press [1] or [3] to configure ENTR side (see illustration). Press [1] for ENTR on left side. Press [3] for ENTR on right side. ENTR on left side of the door Press [1]
ENTR on right side of the door Press [3]
ENTR Dead Bolt User Manual 13 6 Hold the door shut to avoid opening. The lock will carry out the configuration process. It take's 15-20 seconds to complete. Configuration OK
[Manual] indication illuminated.
[Cfg] indication blinks. Note: If the configuration fails refer to troubleshooting #1 7 Open the door using the handle. Bring the latch as close as possible to the door frame. Note: Do not shut the door. Door moldings Magnet 8 Press [Cfg]
The lock will carry out the configuration process. Configuration OK
[OK] Indication blinks once. 2 short beeps emitted, Illuminated buttons turn off. Latch Troubleshooting #1 Lock configuration failed 1. Remove the mechanical key from the lock. 2. Check that the door was closed properly or if lock operation was interfered. 14 ENTR Dead Bolt User Manual Configuration failed
[Error] indication illuminated, 2 long beeps emitted. Refer to troubleshooting #2 Troubleshooting #2 Magnet configuration failed 1. You can still operate ENTR in Manual mode (w/o automatic locking). 2. Remove any other magnets from the door. 3. Place the magnet according to instructions. 4. Consult your installer or contact ENTR Technical Support. Magnet Fitting:
Position the magnet on the door moldings, as close as possible to the lock. The top point of the magnet should align with the lower point of the slider (see illustration). Slider Door frame Magnet ENTR Dead Bolt User Manual 15 3.3 Pairing Remote Control 1 2 Press [Add]
Touch screen with palm or fingers for 3 seconds to active. 3 Numeric buttons illuminated.
[#]
Type [PIN code]
Numeric buttons blinking. 4 Press [1] to add remote control. Illuminated buttons turn off.
[OK] indication blinks for 15 Seconds, waiting for remote control unit 5 Press the remote control button. Remote control button 16 ENTR Dead Bolt User Manual Pairing OK
[OK] indication blinks once, 2 short beeps emitted. Remote control unit added. Pairing failed
[OK] indication blinks for 15 seconds, No beeps emitted. Start the process from stage 1. Notes:
To add more remote control units repeat this procedure. A remote control unit can be paired with only one single door unit. It is possible to add up to 20 remote control units. Only authorized dealer can reset a paired remote. 3.4 Deleting Remote Control The deleting remote control process' will delete all remote control units including Touchpad and Fingerprint readers defined within the system. 1 Touch screen with palm or fingers for 3 seconds to active. 2 Press [Del]
Numeric buttons illuminated. 3 Type [PIN code]
1 long beep emitted.
[#]
ENTR Dead Bolt User Manual 17 4
[Del] blinks for 30 seconds. 5 Press [Del] to confirm. Deletion accomplished
[OK] indication blinks once. 2 short beeps emitted, Illuminated buttons turn off. Note: Wall reader and smartphone connected to the ENTR lock will not be deleted. 3.5 Setting Sound Signal Turn the sound signal to OFF or ON 1 Touch screen with palm or fingers for 3 seconds to active. 2 Press [Mute]
3
[Mute] indication illuminated. Sound signal is off. Notes:
Setting the ENTR lock sound to OFF will mute the lock and unlock sounds, and the open door hazard signal. It will not mute the touchpad, mechanical override and low-battery sounds. Follow the same procedure to turn the sound back to [ON]. 18 ENTR Dead Bolt User Manual 3.6 Setting Locking Mode Toggle between Automatic to Manual locking mode 1 Touch screen with palm or fingers for 3 seconds to active. 2 Press [M A]
3 Type [PIN code]
[#]
4
[Manual] indication illuminated. Notes:
Setting the ENTR lock to Manual will disable automatic locking. Follow the same procedure to set the ENTR lock to Automatic locking. ENTR Dead Bolt User Manual 19 3.7 Doorknob operation Turn clockwise or counterclockwise to unlock. Beep sound emitted during doorknob operation. Important! When an active lock is opened by turning of the knob you must re-operate it by one of its automatic modes (i.e remote, phone, sliding your fingers, touch pad etc.) or else it will remain UNLOCKED. Knob operation is meant solely for mechanical override in the rare event it will not otherwise unlock. 3.8 Slide Buttons Operation Slide your fingers on the recessed grooves on both sides of the ENTR front panel:
To open, slide fingers downwards on the recessed grooves on both sides. To lock, slide fingers upwards on the recessed grooves on both sides. Open Lock 20 ENTR Dead Bolt User Manual 4. Touchpad Reader 4.1 Mounting the Touchpad Reader Select the location where the Touchpad Reader will be mounted. Attach the Touchpad Reader baseplate to the wall. Use 4 screws and screw anchors, or double sided adhesive strip. 4.2 Battery Replacement 1. Release lid screw and open the lid. 2. Put in the batteries (2xAA) according to the "+" "-" signs. 3. Close the lid and tighten the screw. Notes:
After inserting the batteries the Touchpad Reader will turn on automatically. A short beep sound emitted and Green
[OK] indication illuminated for 2 seconds. Important: Do not touch the Touchpad during the self test procedure and until the lights are off. 4.2.1 Low battery indication When batteries need replacement, a red warning signal will blink rapidly and long beep will sound during every lock/unlock action. ENTR Dead Bolt User Manual 21 5. Touchpad Reader Operation 5.1 Operation To turn the Touchpad Reader ON press [#] for 5 seconds. The reader will perform a self test followed by series of beeps. LED blinks Green, Red, Blue. 5.2 Pairing Touchpad Reader This procedure is done via the ENTR lock. See also: Pairing Remote Control. 1 Touch ENTR lock screen with palm or fingers for 3 seconds to active. 2 Press [Add]
3 Numeric buttons illuminated. Type [PIN code]
[#]
Numeric buttons blinking. 4 Press [1] to add Touchpad. Illuminated buttons turn off.
[OK] indication blinks for 15 seconds waiting for the Touchpad. 5 Touch the Touchpad Reader screen with palm or fingers. Press [77]
Blue LED blinking rapidly.
[#]
22 ENTR Dead Bolt User Manual Pairing OK
[OK] indication blinks once, 2 short beeps emitted. Touchpad Reader added. Pairing failed
[OK] indication blinks for 15 seconds, No beeps emitted. In wall reader: Green LED illuminated and 2 beeps emitted. Start the process from stage 1. Hang the Touchpad Reader on the base plate. Tighten fixing screw. Fixing screw ENTR Dead Bolt User Manual 23 5.3 Touchpad Reader Master PIN Code 1 Touch screen with palm or fingers. Press [11]
2 Enter [New master PIN code]
(4-10 digits) For example: 1231234#
[#]
[#]
3 Reenter:
[New master PIN code]
[#]
Master PIN code added Green [OK] illuminated for 1 second. 2 short beeps emitted. Master PIN code not added Red [Error] illuminated for 1 second. 1 long beep emitted. 5.4 Menu Mode Entering menu mode: Press [*]
[Master PIN code]
[#]
5.5 Adding PIN Code (up to 20 different codes) 1 Touch Reader screen with palm or fingers. Press [*]
[#]
[Master PIN code]
Press [11]
[#]
2 Enter [Personal PIN code]
(4-10 digits) For example: 1231234#
[#]
3 Retype:
[Personal PIN code]
[#]
PIN code added Green [OK] illuminated for 1 second, 2 short beeps emitted PIN code not added Red [Error] illuminated for 1 second, 1 long beep emitted. 24 ENTR Dead Bolt User Manual 5.6 Open Door 1 Touch Reader screen with palm or fingers. 2 Press [Personal PIN code]
[#]
Not opening Red [Error] illuminated for 1 second, 1 long beep emitted. 5.7 Lock Door 1 Touch Reader screen with palm or fingers. 2 Press [1]
[#]
Not locking Red [Error] illuminated for 1 second, 1 long beep emitted. 5.8 Delete PIN Code 1 Touch Reader screen with palm or fingers. Press [*]
[#]
Press [33]
[Master PIN code]
[#]
2 For deletion enter:
[Personal PIN code]
[#]
Personal code deleted Personal code not deleted Green [OK] illuminated for 1 second, 2 short beeps emitted. Red [Error] illuminated for 1 second, 1 long beep emitted. 5.9 Delete all PIN Codes 1 Touch Reader screen with palm or fingers. Press [*]
[#]
Press [22]
[Master PIN code]
[#]
2 Enter [Master PIN code]
Reenter: [Master PIN code]
[#]
[#]
Personal PIN codes deleted Green [OK] illuminated for 1 second, 2 short beeps emitted. Note: Master PIN code can not be deleted. Personal PIN codes not deleted Red [Error] illuminated for 1 second, 1 long beep emitted. ENTR Dead Bolt User Manual 25 5.10 Volume Control 1 Touch Reader screen with palm or fingers. Press [*]
[#]
Press [55]
[Master PIN Code]
[#]
2 Press [2] to increase the volume, or [8] to decrease the volume. Press [#] to confirm volume level. 5.11 Factory reset The reset action will delete all PIN codes (master and personal) and will cut off the Touchpad Reader from the ENTR lock. 1 Touch Reader screen with palm or fingers. Press [*]
[#]
Press [99]
[Master PIN code]
[#]
2 Enter [Master PIN code]
[#]
Personal and master PIN codes deleted Personal and master PIN codes not deleted Green [OK] illuminated for 1 second. 2 short beeps emitted. Device performing self test & is factory reset. Red [Error] illuminated for 1 second. 1 long beep emitted. 26 ENTR Dead Bolt User Manual 6. Fingerprint Reader 6.1 Mounting the Fingerprint Reader Prior to starting, select the location where the Fingerprint Reader is to be mounted. Avoid direct sun light to the front panel. Attach the Fingerprint Reader base plate to the wall. Use 4 screws and screw anchors or double sided glued tape. 6.2 Battery Replacement 1. Using a 2mm Allen key release the lid screw and open the lid. 2. Insert batteries (2xAA) according to the
"+" "-" signs. Green LED will illuminate for 2 seconds. 3. Close the lid and tighten the screw. 4. Press on number #5 for 5 seconds. The reader will self calibrate, which will be followed by a series of beeps and blinking LEDs. 6.3 Adjust Date & Time DEVICE DATE/TIME
--/--/--
DD/MM/YY Enter Date Press [OK]
--/--
12 11 1 10 9 8 2 3 4 7 5 6 hh:mm Enter Time Press [OK]
15/03/15 12 11 1 10 9 8 2 3 4 7 5 6 11:00 Press [OK]
ENTR Dead Bolt User Manual 27 6.4 Pairing Fingerprint Reader This procedure is done via the ENTR lock. See also: Pairing Touchpad Reader. 1 Touch ENTR lock screen with palm or fingers for 3 seconds to active. 2 Press [Add]
3 Numeric buttons illuminated. Type [PIN code]
[#]
Numeric buttons blinking. 4 Press [1] to add the reader. Illuminated buttons turn off.
[OK] indication blinks for 15 seconds waiting for the reader. 5 Touch Fingerprint Reader screen. 2 short beeps emitted. Press [OK] for YES or [*] to cancel. PAIR LOCK?
*-NO OK-YES Pairing OK
[OK] indication blinks once. 2 short beeps emitted. Fingerprint Reader added. LOCK PAIR Pairing failed 1 long beep emitted. Red LED illuminated for 2 seconds. FAILED PAIR Note: At the end of the initial pairing process, a short notice will be displayed. 28 NO USERS ENTR Dead Bolt User Manual 6.4.1 Add Master User Setting a Master User requires both fingerprint and PIN code. It is possible to have up to two Master Users. Note: At any stage you can press and hold the [*] key to move to standby mode. MASTERNAME JOHN Type in [Master name]
[OK]
6.4.2 Set Finger MASTER #01 JOHN Blue LED illuminates. Green LED blinking. SWIPE 1st FINGER Swipe 1st finger several times over fingerprint scanner until two confirmation beeps emitted. SUCCESS 2nd FINGER ADD USER SET FINGER Press [OK]
Green LED blinking. SWIPE 2nd FINGER Swipe 2nd finger several times over fingerprint scanner until two confirmation beeps emitted. 6.4.3 Set PIN Code SUCCESS 1st FINGER ADD USER SET CODE Press [OK]
Type in [PIN Code], (4 to 10 digits) ENTER CODE ENTER CODE
******
4-10 digits Press [OK]
Retype [PIN Code]
RETYPE CODE
******
4-10 digits Press [OK]
Matched Codes Mismatched Codes SUCCESS SET CODE FAILED INVALID ENTR Dead Bolt User Manual 29 Hang the reader on the base plate. Tighten fixing screw. Fixing screw OPTION 2:
Touch the Fingerprint Touchpad. Screen shows user code.
[OK]. Enter your code 6.5 Unlock the Door OPTION 1:
Place finger on fingerprint scanner. Short beep emitted & white LED is on. Swipe finger over fingerprint scanner Fingerprint authorized: Blue LED blinking and unlock command is sent. Fingerprint not authorized: Red LED is ON. The device goes to standby. USER CODE 23:49 03/01 Note: In case ENTR lock hasnt succeed to unlock the door, unlock failed message appear on the screen. FAILED UNLOCK 30 ENTR Dead Bolt User Manual 6.6 Lock the Door Touch the Fingerprint Touchpad Press [1]
[#]
6.7 Low battery indication Warning signal blinking. Fingerprint Reader low battery indication Red LED illuminate for 1s after wake-up, 2 long beeps emitted. Door Unit low battery indication Low battery: Red LED illuminate for 1s after wake-up. Extremely low battery:
Red LED illuminate for 1s after wake-up, 2 long beeps emitted. BATTERY LOW BATTERY LOW 6.8 Setting Menu Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01 Enter [Master PIN code]
[OK] or swipe finger over fingerprint scanner SETTING USERS ENTR Dead Bolt User Manual 31 6.9 Add User The unit allows adding up to 20 users. For each user two different fingerprints and one PIN code. Use different user name for each user. 1 2 3 4 SETTING USERS USERS ADD USER 2nd MASTER?
USERNAME JENNIFER User name added. User name added USER #08 JENNIFER Type [USER NAME]
[OK]
*-NO OK-YES Choose [OK] to add 2nd Master User or [*] to add a user. Note: This screen will not appear if two Master Users are defined. 6 Press [OK]
Press [OK]
User name exist 5 USERNAME EXIST Same user name. Choose different user name. ADD USER SET FINGER Press [OK]
1st finger added 7 SWIPE SUCCESS SWIPE 1st FINGER Swipe 1st finger several times over fingerprint scanner until two confirmation beeps emitted. 1st FINGER 2nd FINGER Swipe 2nd finger several times over fingerprint scanner until two confirmation beeps emitted. 2nd finger added 8 9 10 SUCCESS ADD USER SET CODE 2nd FINGER
*-NO OK-YES Press [OK] for YES or [*]
for NO. ENTER CODE ENTER CODE
******
4-10 digits RETYPE CODE
******
4-10 digits Type [CODE]
[OK]
Retype [CODE]
[OK]
Matched codes SUCCESS SET CODE Mismatched codes FAILED INVALID Process did not complete. All data typed in will be erased from memory. 32 ENTR Dead Bolt User Manual 6.10 Delete User Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner SETTING USERS 1 2 3 4 User deleted SETTING USERS Press [OK]
USERS DELETE USER SURE?
DELETED DELETE USER JENNIFER Use [8] or [2] to select user for deletion:
[DELETE USER]
[OK]
*-NO OK-YES Press [OK]
*-NO OK-YES Confirm deletion. JENNIFER Two beeps emitted, Green LED illuminates. Note: The first Master User can't be deleted without doing a factory reset. 6.11 Enable/Disable User Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner. SETTING USERS 1 2 3 User enabled SETTING USERS Press [OK]
USERS ENABLE USER USER ENABLE USER Use [8] or [2] to select user:
[ENABLE USER]
[OK]
JENNIFER Disabled Use [8] or [2] to toggle between users. Press [OK]
ENABLED Two beeps emitted. Green LED illuminates. Note: Repeat this procedure to disable a user ENTR Dead Bolt User Manual 33 6.12 Delete All Users Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner. SETTING USERS 1 2 3 4 All users deleted SETTING USERS Press [OK]
USERS DELETE ALL?
SURE?
SUCCESS DELETE ALL Use [8] or [2] to select:
[DELETE ALL]
[OK]
*-NO OK-YES
*-NO OK-YES DELETED ALL Press [OK]
Press [OK]
Two beeps emitted. Green LED illuminates. 6.13 Add Time Schedule SETTING USERS Press [OK]
1 6 2 3 4 5 USERS ADD SCHED ADD SCHED CHOOSE DAY SARAH Sun-Sat(1-7) SUNDAY FROM 12:00 Use [8] or [2] to
[OK]
select a user Press 1-7 to choose a day. Example: 1 for Sunday. Enter START time
[OK]
Use [8] or [2] to select:
[ADD SCHED]
[OK]
7 SUNDAY TO 13:00 SUNDAY 12:00-13:00
*-No OK-Yes Schedule Saved Enter END time
[OK]
Press [OK] for YES or [*]
for NO Notes:
1. Define up to 7 different time schedules for the same user. 2. Press [*] to go back on every menu. 3. Press [*] for 3 seconds to exit setting menu. 34 ENTR Dead Bolt User Manual 6.14 Edit Time Schedule SETTING USERS Press [OK]
1 6 2 3 4 5 USERS EDIT SCHED EDIT SCHED SARAH SUNDAY 12:00-13:00 Use [8] or [2] to select:
[EDIT SCHED]
[OK]
Use [8] or [2] to toggle between users
[OK]
*-Back OK-Yes Use [8] or [2] to choose the desired schedule to be edited. Pressing on [4] for 3 seconds shall delete the specific schedule. FRIDAY 12:00-13:00 DAY Use [8] or [2] to change schedule day
[OK]
7 8 9 10 FRIDAY 11:00-13:00
--:mm-HH:MM FRIDAY 12:15-13:00 HH:---HH:mm FRIDAY 12:15-17:00 HH:mm---:mm FRIDAY 12:15-17:45 HH:mm-HH:--
FRIDAY 12:15-17:45
*-NO OK-Yes Use [8] or [2] to change the START hour setting. Use [6 ] to move to START minutes. Use [8] or [2] to change START minutes setting. Use [6 ] to move to the END hour. Use [8] or [2] to change END hour setting. Use [6 ] to move to the END minutes. Use [8] or [2] to change END minutes setting. Press [OK] for YES or [*]
for NO. 6.15 Volume Control Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner. SETTING USERS 1 2 3 4 SETTING DEVICE DEVICE VOLUME VOLUME VOLUME SUCCESS Use [8] or [2] to select:
[DEVICE]
[OK]
Use [8] or [2] to select:
[VOLUME]
[OK]
Use [8] or [2] to toggle between HIGH, MEDIUM or LOW. HIGH LOW Press [OK]
SET VOLUME Two beeps emitted. Green LED illuminates. ENTR Dead Bolt User Manual 35 6.16 Double Security After activating the double security option use both methods - swiping a fingerprint and inserting a PIN code to unlock the door. Note: User set up with only one of the settings (fingerprint or PIN code) will not be able to unlock the door. Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner. SETTING USERS 1 2 3 4 SETTING DEVICE DEVICE 2x Security ENABLE?
2x Security Use [8] or [2] to select:
[DEVICE]
[OK]
Use [8] or [2] to select:
[2x Security]
[OK]
*-NO OK-YES Press [OK]
ON Two beeps emitted. Green LED illuminates. 6.17 Factory Reset Warning: A factory reset action will delete all information stored in the memory, including users and paired locks. Touch screen USER CODE MASTER CODE 23:49 03/01 Press [*]
******
23:49 03/01
[OK] or Enter [Master PIN Code]
swipe finger over fingerprint scanner. SETTING USERS 1 2 3 4 Factory reset SETTING DEVICE DEVICE FACTORY Use [8] or [2] to select:
[DEVICE]
[OK]
Use [8] or [2] to select:
[FACTORY]
[OK]
36 RESET?
SURE?
SUCCESS
*-NO OK-YES
*-NO OK-YES FACTORY Press [OK]
Press [OK]
Two beeps emitted. Green LED illuminates. ENTR Dead Bolt User Manual 7. Smartphone App 7.1 App Installation Android smartphone users: go to Google Play to download the ENTR application. System requirements: Android 4.4 iOS (iPhone/iPad) users: go to the app store to download the ENTR application. System requirements: iOS 7.0 or higher. Bluetooth low-energy compliant. The below message will be displayed when opening the ENTR app prior to pairing it with your lock:
"There are no available locks or keys within range". ENTR Dead Bolt User Manual 37 7.2 Pairing a Smartphone This procedure is done via the ENTR lock door unit. 1 Touch the Door Unit screen with your palm or fingers for 3 seconds to activate. 2 Press [Add]. 3 Numeric buttons illuminate. Type [PIN Code]
Numeric buttons blink.
[#]
4 Press [2] to add a smartphone.
[OK] indication blinks for 3 seconds. Illuminated buttons turn off, ENTR will be visible for 5 min. Open the ENTR app and follow the steps described in order to pair the smartphone with the ENTR lock. ENTR App User Manual is available for download at: www.entrlock.com 38 ENTR Dead Bolt User Manual 8. Remote Control Battery Change 8.1 Battery Removal a. Release the lid by safely inserting a small tool into the notch (1), and press the lid clasp (2). Notch 1 2 Clasp b. Take out the push button and intermediate part. c. Take out the electronic board with the battery and remove battery. ENTR Dead Bolt User Manual 39 8.2 Battery Insertion a. Insert new battery (CR2032) into the electronic board according to the "+" "-" signs (1). b. Insert the electronic board into the remote controls housing (2). 1 c. Reassemble the intermediate part and the push button and place over the electronic board. d. Place the lid and press until the clasp clicks into place. 2 Clasp 40 ENTR Dead Bolt User Manual 9. Sabbath Mode Auto-locking and hazard beeps after knob operation are disabled. Battery indication LED blinks every 20 seconds. 1 Touch screen with palm or fingers for 3 seconds to active. 2 Press [Cfg]
3 Numeric buttons illuminated. Type [PIN Code]
[#], Numeric buttons blinking. 4 Press [5] to toggle between activation and deactivation of the Sabbath mode. Sabbath mode activated Sabbath mode deactivated ENTR Dead Bolt User Manual 41 10. Troubleshooting 10.1 Limitations and External Influences 1. Door position sensor might be influenced by external electromagnetic interference. 2. After mechanical key operation, the user should unlock and lock the unit electronically. 10.2 Cases New Unit Installation and Configuration Symptom Corrective action Page The unit isn't accepting my administrative code. Make sure the code you are using contains between 4-10 digits and is different from the "12345" factory code. When I try to start the configuration
(Cfg) process, I'm getting an error sound and light. This could mean that the factory code hasn't been replaced with your administrative code. Go back and set your administrative code. At the end of Step 1 of the configuration process, I'm getting an error sound At the end of Step 2 of the configuration process, I'm getting an error sound. 1. Verify that you are able to lock and unlock the door using the key without issue. 2. Please contact your locksmith 1. Verify that the magnet has been correctly positioned 2. Contact to your locksmith to replace the magnet with a stronger one. I turn the knob, but the lock isn't unlocking. 1. Make sure that the mechanical key can operate the lock 2. Check that the electronic unit is properly attached to the cylinder. 3. Please consult with your locksmith/installer to ensure proper installation was completed. I've configured ENTR, but when I slide my fingers down, the door locks; and when I slide my fingers up, it unlocks -- opposite actions of what should happen. 1. Redo the configuration process. 2. Pay attention to the door's orientation, (Left = 1 and Right = 2). Remote Control Symptom Corrective action I'm having trouble pairing the remote control. 1. Please confirm that the LED on the remote control is ON when you press the button. 2. Repeat the pairing process again while standing closer to the door unit. 3. If after these steps are taken and pairing still isn't working, please contact your locksmith / installer. 12 12 13 13 6 13 Page 16 Sometimes the remote control doesn't open on the first attempt. The remote control operates on RF signal, so you need to be within a certain proximity to the lock. Get closer and try again. 16 42 ENTR Dead Bolt User Manual Constant Usage Symptom Corrective action ENTR has started double beeping whenever I lock or unlock the door. This is an indication your battery is low; it's time to charge the door unit. The unit has started to beep constantly. Sliders aren't responding as expected. The touch panel isn't responding as expected. The latch isn't moving fully into position. 1. Place the knob in the zero position. 2. Please consult your locksmith or installer. Turn the unit off, wait for 3 seconds, and then turn it back on to reset it. Turn the door unit off and wait for 3 seconds. When turning the power back on, avoid touching the front panel until the unit beeps. 1. Pull/push the door toward the frame and observe if the problem is solved. If so, consult your locksmiths to adjust the door or lock case. 2. Verify that the lock is operating smoothly when manually using the key. When I lock or unlock the unit, an error sound occurs. Please consult with your locksmith / installer to adjust the door or lock case. The power adaptor is not charging the door unit. When i fully open the door the knob is touching the wall. Make sure you are using the dedicated ENTR power adaptor that was supplied with your lock. Standard 5V power adaptors WILL NOT charge the unit. Place a doorstop at correct position to prevent the door from opening too widely and damaging the knob or nearby wall. Fingerprint/Touchpad Reader Symptom Corrective action I'm having trouble pairing with the wall reader. I'm having trouble pairing the wall reader with the door unit. The wall reader's blue LED is blinking, but the door unit isn't responding. The touchpad isn't accepting the PIN code I'm entering. 1. Repeat the pairing process until you hear double beep from both the door unit and the wall reader. 2. In some cases, if there are electro-magnetic interferences, there may be a need to repeat the pairing process several times until pairing is completed. Set the door unit to pair mode, by pressing Add + Code
+ 1, then immediately set the wall reader to pair mode. You'll have a 30 second window until the door unit reverts back to standby mode. Verify that the wall reader is paired to the door unit by redoing the pairing process -- you will hear double beeps from both devices when completed. 1. This specific code already exists within the device's memory. 2. Make sure that the PIN code is 4 - 10 digits. ENTR Dead Bolt User Manual Page 31 20 20 12-19 6 6 31 Page 22 22 25 25 43 Symptom Corrective action I have replaced the batteries, but when I press on "5", nothing happens. You need to first power-up the wall reader by pressing and holding the "#" button for 5 seconds. My 5-year old son and his grandmother's fingerprints are no longer working with the fingerprint reader. Both children and the elderly have fingerprints that change. If this occurs, you'll have to repeat the fingerprint learning process for them. Alternatively, they can use a PIN code. The fingerprint Touchpad keys aren't functioning properly. Please go to Setting mode --> Device --> Device, in order to get the product version. Contact your locksmith /
installer for further information and next steps. Mobile App Symptom Corrective action The ENTR mobile app is disconnected from the door unit and/or I can't find my lock on the app. 1. Make sure your phone is compatible with bluetooth 4.0, and that your phone model and OS version are approved for ENTR. 2. Refresh the app. 3. Only one phone can connect to ENTR at the same time. It's possible that another user's phone is already connected to ENTR. If so, close the app on any other user's phone. 4. Close the app, turn off your phone's Bluetooth. Then turn Bluetooth back on, and open the app. 5. Turn the door unit off, and then turn it on again. I've updated the OS on my mobile phone, but the ENTR app still isn't working properly. If you are a lock owner, uninstall and then re-install the app. Then go to My Locks in the app and choose lock recovery. Use your owner password to recover the lock. If you are a user, please ask the lock owner to issue you a new key. I'm unable to complete the 'Set Owner'
process because I can't scan the QR on the ENTR package. I have created a key for a new user, but the user doesn't see that the key is available even though the user is within the lock's Bluetooth range. I'm unable to open the door from a distance of 10 meters / yards. 1. Verify that you have a working internet connection. 2. Try to enter the unit's serial number manually
(IFEU000xxxx). 3. Open a ticket on www.entrlock.com. 1. As only one phone can connect to the lock at the same time, please make sure you have closed your app. 2. Verify that you completed the key creation process by selecting the "active" button. 3. Verify that the new user did not exceed the expiration time you have set for this key. 1. The app works via a Bluetooth connection , which can be impacted by the environment. 2. For both security and functionality reasons, the ideal operating distance should not exceed 5m from the door 3. Try moving as close as possible to the lock. I'm getting strange error messages and/or the app crashed during operation. 1. Verify that you are using a supported mobile device and OS for ENTR app. Page 27 30 6 Page 38 38 38 38 38 37 44 ENTR Dead Bolt User Manual LIMITED WARRANTY Mul-T-Lock hereby warrants, to the end user ("Purchaser") who purchased the genuine Mul-T-Lock product (Product"), from an authorized Mul-T-Lock dealer
(Dealer), that the Product will be free from defects in materials and workmanship
("Defects"), for a period of one year from the date the Product was purchased from Mul-T-Locks authorized dealer. Subject to the terms and conditions indicated below, Mul-T-Lock will repair or replace such Product or part thereof which, upon inspection by Mul-T-Locks authorized dealer, is found to be defective, despite the Product not having been subjected to Improper Activity (as defined below). Improper Activity shall render this warranty void. Improper Activity includes any and all of the following: installation by anyone other than a Dealer: improper installation;
use/operation/maintenance other than in accordance with Mul-T-Locks instructions and requirements (as directed below); tampering by Purchaser; neglect; damage by the application of force; bending; breaks; cracks; scratches; any other act of vandalism; repair or alteration by anyone other than a Dealer: use of keys, key blanks, cylinders, locks, approved batteries, accessories and/or other components that are not suitable and genuine Mul-T-Lock products; all the foregoing as determined by Mul-T-Lock, in its sole judgment. Some basic instructions and recommendations for correct use of the Product are shown overleaf. Mul-T-Locks sole obligation under this limited warranty is to repair or replace, at Mul-T-Locks sole discretion, at the venue of a Dealer, any Product and/or Product component found by Mul-T-Lock to have Defects. This limited warranty does not grant any other rights or give rise to any other obligation, or absolve Purchaser of the responsibility to employ any other suitable measures, by whatever means, including insurance, against the risk of personal injury or damage to property. This limited warranty relate to products defects only. Mul-T-Lock shall be liable, in any event, for any labour costs associated with the product and its installation process. In order to facilitate the warranty service and enable Mul-T-Lock to determine entitlement under this warranty, Purchaser must first return the Product, with proof of purchase from a Dealer, to Mul-T-Lock, either directly, or through the Dealer from whom Purchaser purchased the Product. All shipping, handling, travel, service call and/
or other incidental and/or related charges are fully payable by Purchaser only and are not included in this limited warranty. ENTR Dead Bolt User Manual 45 THE USE OF OTHER THAN SUITABLE, GENUINE MUL-T-LOCK COMPONENTS MAY CAUSE SEVERE DAMAGE TO THE PRODUCT, AND WILL VOID THIS LIMITED WARRANTY. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE TRANSFERRED IN ANY WAY AND MAY NOT BE EXTENDED, ALTERED OR VARIED. TO THE FULLEST EXTENT ALLOWABLE BY THE LAWS APPLYING HERETO, THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH ARE EXPRESSLY EXCLUDED AND DISCLAIMED. MUL-T-LOCK WILL NOT BE LIABLE FOR LOSS OF PROFITS, ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHICH PURCHASER MAY SUSTAIN, OR PUNITIVE DAMAGES, EVEN IN THE EVENT OF NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. Some Basic Instructions and Requirements for Correct Use of ENTR Products Protection of Keys:
Keys should be used only for their original purpose, of operating the corresponding Your key carries a code. Make sure you keep it concealed. Only genuine Mul-T-Lock key blanks should be used. Duplicate keys must be performed by an authorized Mul-T-Lock locksmith on Mul-T-Locks key cutting machine. Keys must be inspected periodically and must be replaced when show physical wear. Cylinders:
Installation must be performed by an authorized Mul-T-Lock dealer only. Cylinders must not be submerged in water, or exposed to any chemical wash, or be cylinder. painted. Protect the cylinder from dirt & dust. Protect your cylinder from exposure to extreme temperatures. (External -20 C to
+80C, Internal -10C to +50C) The cylinders keyway should be lubricated at least once per year (preferably using lubricants authorized by Mul-T-Lock, or light machinery oil). In any heavy use environments, extreme weather conditions, lubrication must be conducted every three months. 46 ENTR Dead Bolt User Manual LEGAL NOTICES Mobile phones ENTR warranty should not cover any problem related with end user mobile phone/
smartphone or its operation system, by connecting to ENTR lock or installing ENTR application. For any other limitation please refer to End User licence agreement. Items excluded / limited from this warranty Screws Normal wear and tear Cleaning with cleaning detergents Warranty for ENTRs Main battery is limited for 1 year Trademarks Mul-T-Lock and ENTR are trademarks/trade names belonging to Mul-T-Lock Ltd. No unauthorised use may be made of these trademarks. No Insurance No security product can ever guarantee the safety of assets. The ENTR product is by no means a substitute for suitable insurance coverage protecting against loss or damage of your property. Mul-T-Lock is not an insurance company and does not provide insurance services of any kind. External Influences Services are subject to various external influences, outside our control, such as satellites and cellular or other communications networks, and may also be influenced by weather conditions, frequency jamming/interference, improper use or activity, interference, vandalism, destruction etc. Services may also be adversely affected, or rendered impossible when the ENTR product is located in places where a signal may not be available - for example, a garage, parking lot, tunnel or other such location. The fingerprint sensor may not work for certain members of the population, for physiological reasons Limitations of Services and Liability The Services will not always provide an accurate picture of whether or not assets have been subject to unauthorized access - for example, if the ENTR product is accessed using the original key or a duplicate key. Proper functioning of the ENTR product may be impaired if the ENTR product is not installed and maintained properly, in accordance with the instructions provided with the ENTR product. Installation and/or disassembly must be carried out only by authorised ENTR installation personnel. ENTR Dead Bolt User Manual 47 For radio enclosure Federal Communications Commission (FCC) Statement Labelling requirement for small device statement (FCC15.19(3)) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Radio Frequency Interference (RFI) (FCC 15.105) This equipment has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Labeling Requirements (FCC 15.19) This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications (FCC 15.21) Changes or modifications to this equipment not expressly approved by Mul-T-Lock may void the users authority to operate this equipment. RF Exposure info ( FCC 2.1093)-for module radio This equipment has been approved for mobile applications where the equipment should be used at distances greater than 20cm from the human body (with the exception of hands, wrists, feet and ankles). Operation at distances less than 20cm is strictly prohibited. 48 ENTR Dead Bolt User Manual
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-09-30 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2016-09-30
|
||||
1 | Applicant's complete, legal business name |
MUL-T-LOCK TECHNOLOGIES LTD
|
||||
1 | FCC Registration Number (FRN) |
0025321845
|
||||
1 | Physical Address |
aharon.vardi@mul-t-lock.com
|
||||
1 |
Yavne, N/A 8156218
|
|||||
1 |
Israel
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AHH8
|
||||
1 | Equipment Product Code |
81130
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A**** V****
|
||||
1 | Telephone Number |
+9728******** Extension:
|
||||
1 | Fax Number |
+9728********
|
||||
1 |
a******@mul-t-lock.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
MUL-T-LOCK TECHNOLOGIES LTD
|
||||
1 | Name |
A**** V********
|
||||
1 | Physical Address |
Mul-T-Lock Park
|
||||
1 |
637
|
|||||
1 |
Yavne, 8110601
|
|||||
1 |
Israel
|
|||||
1 | Telephone Number |
+9728********
|
||||
1 |
A******@mul-t-lock.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Electromechanical door cylinder | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output Power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Qualitech
|
||||
1 | Name |
M**** B********
|
||||
1 | Telephone Number |
972-3********
|
||||
1 | Fax Number |
972 3********
|
||||
1 |
M******@ecitele.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0015500 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC