all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.65 MiB | March 06 2020 | |||
1 |
|
Internal Photos | Internal Photos | 2.89 MiB | March 06 2020 | |||
1 |
|
External Photos | External Photos | 2.62 MiB | March 06 2020 | |||
1 |
|
Label & Location | ID Label/Location Info | 93.02 KiB | March 06 2020 | |||
1 |
|
731 Signature Authorization Letter | Cover Letter(s) | 115.32 KiB | March 06 2020 | |||
1 |
|
Authorization Letter | Cover Letter(s) | 114.39 KiB | March 06 2020 | |||
1 | Block Diagram | Block Diagram | March 06 2020 | confidential | ||||
1 |
|
Confidentiality Request Letter | Cover Letter(s) | 117.19 KiB | March 06 2020 | |||
1 | Operational Description | Operational Description | March 06 2020 | confidential | ||||
1 | Parts List | Parts List/Tune Up Info | March 06 2020 | confidential | ||||
1 | Schematics | Schematics | March 06 2020 | confidential | ||||
1 | Test Report | 3.87 MiB | March 06 2020 | |||||
1 | Test Report | 3.42 MiB | March 06 2020 | |||||
1 |
|
Test Setup Photos | Test Setup Photos | 1020.06 KiB | March 06 2020 | |||
1 |
|
Tune Up Procedure | Parts List/Tune Up Info | 113.15 KiB | March 06 2020 |
1 | User Manual | Users Manual | 3.65 MiB | March 06 2020 |
Instruction Manual EBK1 EBK2 Echo Base Kit Package, 1 Barn
(1=US, 2=Global) Echo Barn Kit Echo Base Kit Package, 1 Barn Models: EBK1 EBK2 Munters Corporation, February 2020 QM1601r1A 1 EBK1/EBK2 Echo Barn Kit Instructions for Use and Maintenance Thank You:
Thank you for purchasing a Munters EBK1/EBK2 Echo Barn Kit. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note:
To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty:
For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at aghort.info@munters.com. Conditions and Limitations:
Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1601r1A Munters Corporation, February 2020 Index Chapters 1. Unpacking the Equipment 1.1 Parts List 1.2 Tools for Installation 1.3 Supplies not supplied by Munters 2. Installation Instructions 2.1 Installation Process 2.2 Echo Enclosure Mounting Tabs 2.3 Junction Box (JBox) Preparation 2.4 Junction Box (JBox) Mounting 2.5 Junction Box (JBox) 24vdc Wiring 2.8 Echo Power Supply and Surge Protector 2.9 Echo EPS and Water Meter 3. Troubleshooting 4. Echo Log Process 4.1 Conguring the Mobile Application 4.2 Adding/Registering a new device 6. Testing and Calibrating 7. FCC Compliance 8. Warranty 2.10 Echo Hub 1: Echo Temperature/Humidity & Automatic Bird Scale optional Ammonia Sensor 2.11 Echo Hub 2: Echo Pulse Splitter and Automatic Silo Scale Page 4 4 6 6 7 7 7 7 9 9 12 14 15 19 22 26 26 28 31 38 40 Munters Corporation, February 2020 QM1601r1A 3 Unpacking the Equipment 1. Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all components for signs of shipping damage. Any shipping damage is the customers responsibility and should be reported immediately to your freight carrier. EPS100: Echo Water Consumption Kit:
ECHO-24VDC-SPLY FC3496 EA1002 1.1 Parts List Each EBK1/EBK2 is shipped with:
EPW100: Echo 24VDC Power Distribution Kit:
1 ECHO-24VDC-SPLY 1 EA1002 3 FC3496 1 HP1473 1 ECHO-EPS 1 ECHO-ETH 1 HP1472 1 ECHO-EBS 1 EB2110 ETH100: Echo Temperature/Humidity Sensor Kit:
EBS100: Echo Automatic Bird Scale Kit:
ECHO-ETH ECHO-EPS ECHO-EBS EB2110 4 QM1601r1A Munters Corporation, February 2020 Chapter 1 Unpacking the Equipment HP1473 Hardware Package for EPW100 Cat. No. FC1208 Description 5-Pole Terminal Block Qty. 6 12 12 WC3208M Watertight Fitting w/ Nut, .11-.25D Cable, NY
#9 x 1.5 Hex, Seal Washer Polebarn Screw, BLK KS1402 HP1474 Hardware Package for EAP100/105 Qty. Cat. No. Description WC3208M Watertight Fitting w/ Nut, NY KS1402
#9 x 1.5 Hex, Seal Washer Polebarn Screw, BLK WC3220EC Watertight Fitting w/ Nut, .21-.33D E-Net, NY KE2460 Ethernet Cable,3L.,RJ45 CAT6, GRAY or BLK HP1475 Hardware Package for FC4303 Qty. Description
#9 x 1.5 Hex, Seal Washer Polebarn Screw, BLK WC3220EC Watertight Fitting w/ Nut, .21-.33D E-Net, NY
-20 x SRTD Hex Flange Bolt, ZP
-20 Serrated Hex Flange Nut, ZP 14.1 50 LB, UV Resistant Wire Tie, Black NY Cat. No. KS1402 KS1153 KN0730 KE1106 HP1472 Hardware Package for ETH100 Qty. Cat. No. AC1015 Description x 150L. Lift Line, Braided Polyester, WHT AC0211 & AC0212 Azuma Bolt & Nut, Blue PL KS2601 6 GA x 1.875L. Open Eye Lag Screw, ZP HP1475 Hardware Package for EB2110 Qty. Cat. No. KS1402 KS1073 KW3513 KW3029 KX1139 KS2767 KX1092 AC1385 Description
#9 x 1.5 Hex, Seal Washer Polebarn Screw, BLK
-10 x 1.75 Hex Bolt, SS Splitlock Washer, SS ID x 1.75OD Flat Washer, SS
-16 x Star Knob, SS & PL
-13 x 6.75 Hook Type Bolt w/ Nut, ZP x 3.94 Spring Snap Hook, ZP 2Dia. Hitching Ring w/ Bracket, ZP ID
[A]
[B]
[C]
ID
[B]
[C]
[D]
[E]
ID
[C]
[D]
[F]
[G]
[H]
ID
[J]
[K]
[L]
ID
[C]
[M]
[N]
[P]
[R]
[S]
[T]
[U]
1 4 1 1 4 1 2 2 3 1 2 1 4 1 1 2 2 1 1 1
[T]
[U]
[A]
[B]
[C]
[D]
[F]
[G]
[K]
[L]
[M]
[N]
[P]
[R]
[S]
Munters Corporation, February 2020 QM1601r1A 5 Chapter 1 Unpacking the Equipment 1.2 Tools Required by Installer (not provided) Tools/Supplies Rotary Hammer Drill Concrete Drill Bit Diameter 3 lb sledge for concrete anchor Diameter Socket 1 Open End Wrench Diameter Socket Open End Wrench Drill Bit - Titanium or Cobalt for hardened steel Knee pads 1 Diameter Socket Claw Hammer Cordless Drills chuck Drill Bits (Assorted Sizes) Drill Screw Setters & Drivers Phillips, driver, etc Cordless Impact Uni Bit (Step Bit) drilling plastic box holes, " dia. and " dia. Hole Saw Diameter = pvc conduit. For drilling hole through the wall for conduit Flash light Echo Kit ELK100 ELK100 ELK100 ELK100 ELK100 ELK100 ELK100 ELK100 ELK100 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 1.3 Recommended Supplies not supplied by Munters Echo Kit EBK1/2 EBK1/2 Tools/Supplies 18/2 Cond Shielded Cable 24Vdc power 18/4 Cond Shielded Cable For Water Meters to Echo EPS & for Echo EPS to ventilation controller PVC Conduit or 1 diameter. Length = barn wall thickness. 3 entrys per barn. These are for passing wire through the wall in 3 spots of barn PVC Coupler Diameter = PVC conduit. For keeping conduit from sliding out of wall. 2 per conduit Staples/Wire Fasteners Diameter = wire/cable sizes. To secure low voltage wire in building Zip Ties Length 8 - option to secure low voltage wire in building Zip Ties Length 14 (UV rated) to secure low voltage wire from feed bin scale unit on feed lines entering the building For Outside US: installation Countries VAC cords or plug adapters for Ubiquity Access Point, 24Vdc Power Supply and Power Strips. If supplied from Lansing will have US 120 VAC Plugs 18/3 Cond Shielded Cable For RS232 communication of (2) Luamus Bin controls to (2) Echo ESS ESK100 Option: 18/5 Cond Shielded Cable - for combining (2) Laumus 24v power & RS232 to (2) Echo ESS ESK100 Ground wire Size 12 AWG, calculate approx 15 feet per feed bin. Color green ESK100 Ground Rod - Diameter . Length 10. If 1 ground rod per feed bin does not already exist EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 EBK1/2 Ground Rod Clamp Diameter same as rod Cutting Oil (2) diameter holes drilled into each feed bin leg ELK100 ELK100 ELK100 6 QM1601r1A Munters Corporation, February 2020 Installation Instructions 2. 2.1 Installation Process The installation of the Barn Kit may vary from our illustrations depending on the layout of the barn or farm. There are many similarities between barns and farms which allow for repeated installations or setups that we have attempted to show here in our installation manual. When barn design variations require a dierent approach from how placing the hardware inside the control room, main house or outside are shown, feel free to contact Munters for support and recommendations. 2.2 Echo Enclosure Mounting Tabs Step 1 Each Echo Sensor Enclosure is supplied with a packet of four mounting tabs and hardware. Attach one mounting tab to each corner of the enclosure back using one of the machine screws supplied. See Figures 1A, 1B and 1C. Failure to use screw provided leads to potential of other screw to pass through enclosure and make contact with circuit board, causing Echo failure. Figure 1B Figure 1C Figure 1A Repeat Step 1 with all remaining Echos. 2.3 Junction Box (JBox) Preparation Step 2 Step 3 Step 4 Each EPW100, contains (3) Junction Boxes. JBox mounted locations and wiring path to Echos will determine number of 24vdc input and output wires required per enclosure and the watertight fittings to prepare holes for. If provided, consult the Munters Sonar/Echo layout drawing for locations of JBoxes. JBox enclosure Cover and Bottom align using the molded plastic male/female alignment offset tab found in one of the 4 corners cover screws. Incorrect alignment allows improper sealing of enclosure top and bottom, potentially leading to moisture or other foreign debris to enter and disrupt Echo Power System. Munters Corporation, February 2020 QM1601r1A 7 Chapter 2 Installation Instructions Do not bring wires through either the sides, top or front of the enclosure. See Figure 2. With number of holes and top/bottom determined, mark wire in/out locations on bottom of enclosure. Example shows 3 in/out locations. See Figure 3. Figure 2 Figure 3 Using a Uni Bit, drill dia. holes at each mark. See Figure 4. Insert a Watertight Fitting [B] into each hole and secure with nut. See Figure 5. Step 5 Step 6 Step 7 Step 8 Step 9 Figure 4 Figure 5 Recommended placement of JBoxes in house are at Control Room Sidewall, Opposite side of Building, at both ESS Automatic Silo Scales, and at the best Echo position to provide best coverage for up to two conductor wires. If provided, consult the Munters Sonar/Echo layout drawing for locations of JBoxes. 8 QM1601r1A Munters Corporation, February 2020 Chapter 2 Installation Instructions 2.4 Junction Box (JBox) Mounting Step 10 After determining the locations for the JBoxes, hold bottom of JBox up to wall, making sure that the watertight fittings point down and drill two pilot holes for mounting screws. See Figure 6A and 6B. Then fasten to wall using (2) Screws [C]. See Figure 6C. Next mount the remaining JBoxes. Figure 6A Figure 6B Figure 6C 2.5 Junction Box (JBox) 24vdc Wiring NOTE: Two-Conductor, Shielded Cable, 18 AWG recommended. Step 11 Step 12 Pull shielded cable to 1st JBox. See Figure 7A. From 1st JBox, pull shielded cable to 2nd JBox. See Figure 7B. Repeat this for 3rd JBox. Repeat Step 11 for any Echo at the end of line, such as the EBS. Repeat Step 11 for 24v to POE box (see Access Point instructions). Repeat Step 11 for any Echo placed in other areas of house, for example the ETH. From 1st JBox pull one shielded cable to each Echo it is meant for. Repeat step for each JBox to Echo it is meant for. This allows no junctions are done inside Echo and each has its own 24vdc power wire. Terminate cable in Echo and note wire colors used for +24vdc and --24vdc polarity. Figure 7A Figure 7B Munters Corporation, February 2020 QM1601r1A 9 Chapter 2 Installation Instructions Step 13 At 1st JBox, strip wire insulation from all cables in JBox. See Figure 8A. Next, strip ends of each individual wires. See Figure 8B. Figure 8A Figure 8B Step 14 Locate (2) WAGO 5-Pole Terminal Blocks [A]. One Terminal Block [A] will be for one color of wire and the other Terminal Block [A] will be for the 2nd color of wire. For example Black and White wires or Black and Red wires. Lift lever and insert wire into Terminal Block and lock in place by lowering lever. See Figure 9A and 9B. Figure 9A Figure 9B Step 15 Connect all bare shield wires together using 18 AWG wire nut or equivalent (not provided). See Figure 10A and 10B. 10 QM1601r1A Munters Corporation, February 2020 Figure 10A Figure 10B Chapter 2 Installation Instructions Repeat Steps 13-15 for remaining JBoxes. NOTE: Installing Echos without connecting bare shield between terminal block and main power ground increases EMI noise potential in the Echo Sensors circuitry. Step 16 Step 17 Secure cabling ran in barn with wire staples, zip ties or equivalent. See local electrical codes for acceptable methods. See Figure 11. Figure11 Munters Corporation, February 2020 QM1601r1A 11 Chapter 2 Installation Instructions 2.8 Echo Power Supply and Surge Protector Step 42 In Control Room select a 120VAC outlet to use for power and determine where to mount the Surge Protector and 24vdc Power Supply. If provided, consult the Munters Sonar/Echo layout drawing for locations of Surge Protector and Power Supply. See Figure 39A and 39B. Step 43 Step 44 Figure 39A Figure 39B Locate the (4) mounting holes on the back of the Surge Protector. Hold the Surge Protector up to the wall and mark the location for the (4) mounting holes. See Figure 40A and 40B. Figure 40A Figure 40B Using the mounting screws provided with the Surge Protector, run screws into wall at the positions marked leaving space between the screw head and wall. See Figure 41A and 41B. Figure 41A Figure 41B 12 QM1601r1A Munters Corporation, February 2020 Chapter 2 Installation Instructions Step 45 Attach Surge Protector to wall by sliding mounting holes over wall screws and sliding the Surge Protector down until it locks in place. See Figure 42A and 42B. Figure 42A Figure 42B Step 46 Step 47 Locate the Echo Power Supply. If the mounting tabs are not already installed to the back, See Step 1 and 2 to install the mounting tabs on the Echo Power Supply. Mount the Echo Power Supply to wall using (4) Screws provided and Mounting Tabs. See Figure 43. Figure 43 Step 48 Plug the Echo Power Supply into Surge Protector, then plug the Surge Protector into 120V outlet. See Figure 44A and 44B. Figure 44A Figure 44B Munters Corporation, February 2020 QM1601r1A 13 Chapter 2 Installation Instructions 2.9 Echo EPS and Water Meter Step 49 The Echo EPS can be connected to up to 4 existing digital water meters. Mount EPS inside building, near the water meters. Location is important to minimize wiring and allow for good wifi reception. Allow for any wiring to pass through wall from both the water meter and ventilation control. See Figure 45A, 45B and 45C. Figure 45A Figure 45B Figure 45C Step 50 Install Option 1: Determine if the water meter wire to the barn control can be rerouted and used again. The wire must reach the EPS output. Add a two wire shielded cable from the water meter to the EPS input. See Figure 46A. Install Option 2: Add a new four wire shielded cable from the EPS to the water meter. See Figure 46B, 46C and 46D. WHITE & BROWN = WATER METER RED & BLACK = BARN CONTROL Figure 46A Figure 46B Figure 46C Figure 46D 14 QM1601r1A Munters Corporation, February 2020 Chapter 2 Installation Instructions 2.10 Echo Hub 1: Echo Temperature/Humidity & Automatic Bird Scale w/ option to add Ammonia Sensor Step 51 Hub 1 will measure Temperature, Humidity, Bird Weights and Ammonia (with optional ammonia sensor added). Install Mounting Tabs to enclosure (See Step 1). With Braided Polyester Lift Line [J] create a loop through the top two mounting tabs and fasten Lift Line to itself using Azuma Bolt & Nut [K] to allow for future adjustment. See Figure 47A and 47B. Figure 47A Figure 47B Step 52 Install Open Eye Lag Screw [L] in ceiling truss. Allow Lift Line to hang from Lag Screw [L] and hang Hub 1 Enclosure. See Figure 48A. NOTE: Minimum height from floor to be out of birds reach. See Figure 48B. Figure 48A Figure 48B Munters Corporation, February 2020 QM1601r1A 15 Chapter 2 Installation Instructions Step 53 Determine the location for the Hanging Automatic Bird Scale Platform. Drill four pilot holes into truss or solid cross board using the Hitching Ring [U] as a guide. Then using (4) Screws [C] attach Hitching Ring
[U] to ceiling. See Figure 49. Step 54 Hook one end of the Automatic Bird Scale Load Cell to Spring Snap Hook [T], then hook the Spring Snap Hook [T] to the Hitching Ring [U]. See Figure 50. Figure 49 Figure 50 16 QM1601r1A Munters Corporation, February 2020 Chapter 2 Installation Instructions Step 55 Step 56 Locate the smaller Automatic Bird Scale Pole and thread the Hook Bolt with Nut [S] into the end of pole with nut until the 2 nuts meet. See Figure 51. Smaller Pole w/ Nut Hook Bolt w/ Nut Figure 51
" or Greater Start to thread (2) Star Knob [R] into the two holes in the larger Automatic Bird Scale Pole. Slide the smaller Automatic Bird Scale Pole into the larger Pole to the desired position and lock in place by tightening Star Knobs [R]. See Figure 52A and 52B. Larger Pole w/ Nut Star Knobs [R]
Smaller Pole w/ Nut Larger Pole w/ Nut Figure 52A Figure 52B Step 57 On the end of the larger Automatic Bird Scale Pole with the nut, attach the Automatic Bird Scale Platform and Balancing weight to the pole using (2) Washer [P], (1) Splitlock Washer [N] and Bolt [M]. See Figure 53. Larger Pole w/ Nut Washer [P]
Automatic Bird Scale Platform Balancing Weight Washer [P]
Splitlock Washer [N]
Bolt [M]
Figure 53 Munters Corporation, February 2020 QM1601r1A 17 Chapter 2 Installation Instructions Step 58 Hang the hook end of the Automatic Bird Scale Platform assembly on the Automatic Bird Scale Load Cell. Use the Star Knobs to adjust the height of the Platform. See Figure 54. Hitching Ring [U]
Spring Snap Hook [T]
Automatic Bird Scale Load Cell Automatic Bird Scale Hanging Rod Automatic Bird Scale Platform Figure 54 18 QM1601r1A Munters Corporation, February 2020 Chapter 2 Installation Instructions 2.11 Echo Hub 2: Echo Pulse Splitter and Automatic Silo Scale Step 59 Hub 2 will measure 1 - 4 water meter pulses and feed bin weights. Install Mounting Tabs to back of Hub 2 enclosure (See Step 1). Locate a mounting spot on the outside wall near the feed bins. Allowing the four conductor, shielded cable(s) to enter wall from ESBS Feed Bin Junction Box(es). See Figure 55. Figure 55 Step 60 Pull four conductor, shielded cable from the ESBS and route wires into Hub 2 through one of the provided watertight fittings. Terminate wires to the Scale Input terminals, SH(shield), EX+(Red), S+(Green), S--(White), EX--(Black). See Figure 56A. Install additional Hub 2s and repeat this step for wiring instructions for additional feed bins or if feed bins and water meter proximity is out of reach. See Figure 56B. Figure 56A Figure 56B Munters Corporation, February 2020 QM1601r1A 19 Chapter 2 Installation Instructions Step 61 Determine number of water meters to be measured. Recommended method of routing wires is from water meters to Hub 2 Water Meter # Input. Then from that Water Meter # Output to the Main Control. See Figure 57. Output #4 Input #4 Output #3 Input #3 Output #2 Input #2 Output #1 Input #1 Figure 57A Figure 57B NOTE: A Qualied Electrician is recommended when working inside barn control. All wiring should be installed in accordance with National, State, and Local electrical codes. Step 62 Connect FLW#1 INPUT to Water Meter #1. Connect FLW#1 OUTPUT to Barn Control Water Meter #1. Repeat this step for Water Meter #2, #3 and #4. See Figure 57B. 20 QM1601r1A Munters Corporation, February 2020 Troubleshooting 3. 3.3 Echo Troubleshooting Procedures The troubleshooting procedures on the following pages are used to identify the cause of problems with an Echo installation. The most common problem is expected to be an Echo that is oine and not sending data reports to Sonar. If the Sonar app indicates that an Echo is oine, start at the top of the Echo Not Sending Data Reports procedure. That diagnostic procedure may lead you to another procedure, such as one of those listed below:
connected. Echo Not Connecting To Wi: The Echo has power and is trying to connect to WiFi, but has not Echo Not Connecting To Sonar: The Echo has power and is connected to WiFi. It's trying to connect to Device Not Able To Reach Internet: An Echo or a WiFi Access Point (AP) is connected but unable to Sonar, but has not connected. access the Internet. These diagnostic procedures assume that the user has access to the farm's houses and control rooms, plus these tools:
mobile devices is recommended. The EchoLog mobile app A mobile device that detects nearby WiFi APs and their signal strength. The WiFi Analyzer app for Android A Fluke Networks LinkSprinter 100 Network Tester A Tripp Lite Network Cable Continuity Tester for Ethernet cables, or equivalent An Ethernet PoE power detector that can detect 24 VDC Active and Passive PoE Munters Corporation, February 2020 QM1601r1A 21 Chapter 3 Troubleshooting 22 QM1601r1A Munters Corporation, February 2020 Chapter 3 Troubleshooting Munters Corporation, February 2020 QM1601r1A 23 Chapter 3 Troubleshooting 24 QM1601r1A Munters Corporation, February 2020 Chapter 3 Troubleshooting Munters Corporation, February 2020 QM1601r1A 25 Echo Log Process 4. On your mobile device go to the Play Store (Android) or to App Store (iphone) and search and download application EchoLog (Munters). After installations of the Echo units have been completed, you will scan the QR code on the sensor boxes, this will activate the sensor installed to start transferring data to the cloud. The Farm Kit will allow for EchoMesh Wi-Fi network to become functional. For the Farm Kit, you will not need to scan the QR code. This is done for:
Echo Temperature Humidity Sensor Echo Automatic Bird Scale Sensor Echo Automatic Silo Scale Sensor Echo Pulse Splitter 4.1 Configuring the Mobile Application Step 1 Open EchoLog mobile application. See Figure 60. Figure 60 Step 2 Enter the following in the fields: See Figure 61. Username: (Provided by Munters) Password: (Provided by Munters) Figure 61 26 QM1601r1A Munters Corporation, February 2020 Chapter 4 Echo Log Process Step 3 Step 4 Confirm that the location services (GPS) is enabled for auto barn location detection. Select the farm in which you are working. See Figure 62. Google Maps displays your location. Figure 62 Step 5 Step 6 Confirm your location by clicking the Right Arrow sign (option). Select specific house from the list. See Figure 63. Figure 63 Munters Corporation, February 2020 QM1601r1A 27 Chapter 4 Echo Log Process 4.2 Adding/Registering a new device Step 1 Click the [ + ] sign to add a new Echo Manufacturing sensor device on the site. See Figure 64. Figure 64 Step 2 Click SCAN and point the camera to the printed QR sticker. See Figure 65. Figure 65 28 QM1601r1A Munters Corporation, February 2020 Chapter 4 Echo Log Process Note: You can insert the QR code manually, via mobile devices keyboard:
a. Click the mobile devices Back button. The QR code camera closes. b. Click Device Serial #. The keyboard appears. c. Insert the serial number (found under the QR code). d. Click the Right Arrow key to complete the process. Select the System Location (Front/ Middle/ Back). See Figure 66. Step 3A Step 3B Step 3C For ESS, select Feed Bin (A, B, etc.). For EPS select Liter/Gallon. select Quantity select No. of Meters Step 4 Step 5 Click Install. See Figure 67. Click Save. See Figure 68. Displays values transmitted by the EPS. Figure 66 Figure 67 Figure 68 Munters Corporation, February 2020 QM1601r1A 29 Chapter 4 Echo Log Process Device Name Echo Temperature/RH Common Name ETH Technical Description Vdc Input: 12-28VDC The sensor shows best performance when operated within recommended normal temperature and humidity range of 5 60C [41 - 140F] and 20 80 %RH, respectively. Long term exposure to conditions outside normal range, especially at high humidity, may temporarily oset the RH signal (e.g.+3%RH after 60h at >80%RH). After returning into the normal temperature and humidity range the sen-
sor will slowly come back to calibration state by itself. Vdc Input: 12-28VDC Load Cell capacity 50Kg Echo Automatic Bird Scale EBS Echo Automatic Silo Leg Bracket ESLB Echo Automatic Bird Scale Platform Echo Automatic Bin/Silo Scale ESS Junction Box for Bin Wiring ESBS Echo Pulse Splitter EPS Vdc Input: 12-28VDC 4 wire connection to ESBS Summing Box Shield connector Outdoor enclosure Up to 8 Load Cells 3mV/V Screw-clamp terminals Vdc Input: 12-28VDC Split pulse of up to 4 water meters Echo Quick Lift Load Cells Load cell capacity 10KLb Echo Mesh Echo Power Supply
(Attached) Power supply: 90-264VAC Output: 24VDC 60W 2.5A Image
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
<insert device image>
30 QM1601r1A Munters Corporation, February 2020 Testing and Calibrating Required: EchoLog App. If username and password required contact Munters Step 1 Open EchoLog 6. Step 2 In ECHO Farms select Farm Munters Corporation, February 2020 QM1601r1A 31 Chapter 6 Testing and Calibrating Step 3 Select House number For ESS proceed to next step. For EBS skip to step xx 6.1 ESS & ESBS - Automatic Silo Scales Step 4 Calibrate Step 5 Select Silo Weight ESS to be calibrated. 32 QM1601r1A Munters Corporation, February 2020 Chapter 6 Testing and Calibrating Step 6 Step 7 Step 8 Select Menu at the top of the screen Select Theoretical Calibrate Enter No. of Load Cells (examples 4, 6 or 8) Enter 1 Load Cell Capacity (ex. 10,000 lbs) Enter current Feed Weight (example 0 or from feed ticket delivery) Step 9 Step 10 Step 11 Press Calibrate Munters Corporation, February 2020 QM1601r1A 33 Required: EchoLog App. Test mode will show new values every 10 seconds for two minutes. The weight in use value should appear in EchoLog from the weight being detected after it was applied or after it was removed. Chapter 6 Testing and Calibrating Test Step 1 Step 2 Step 3 Step 4 In EchoLog select ESS to be tested. Select Menu at the top of the screen Select Test Stand on Each Leg and view EchoLog to conrm the weight increase equals body weight 34 QM1601r1A Munters Corporation, February 2020 Chapter 6 Testing and Calibrating 6.2 EBS - Automatic Bird Scales Calibrate Required: EchoLog App. Any type of weight can be use with its known weight value. Example a 1.0kg barbell weight has been weighed elsewhere and is 1.03kg (1030grams). Step 1 In EchoLog select EBS to be calibrated. Step 2 Select Menu at the top of the screen Munters Corporation, February 2020 QM1601r1A 35 Chapter 6 Testing and Calibrating Step 3 Step 4 Select Calibrate Follow remaining instructions provided in EchoLog. Required: EchoLog App. Two test weights are recommended. The calibration weight can be used and a second weight recommended is 50 grams (approximately a 1 day old bird). Test mode will show new values every 10 seconds for two minutes. The weight in use value should appear in EchoLog from the weight being detected after it was applied or after it was removed. Test Step 1 In EchoLog select EBS to be tested. 36 QM1601r1A Munters Corporation, February 2020 Chapter 6 Testing and Calibrating Select Menu at the top of the screen Step 2 Step 3 Step 4 Select Test When Test Mode begins the screen will start showing 1. EchoMesh WiFi Signal strength 2. Last Reading Time will update to the current clock time and then change every 10 seconds. 3. Weights Step 5 Step 6 Step 7 Step 8 Once the weight shows 0.0, place the known test weight on the scale. Within the next 10 seconds, the new cycle will change and this known weight appears in EchoLog. If not wait another 10 seconds or until the known test weight eventually appears. Go to step 6. When 0.0 reappears, remove the rst test weight. In the next 10 second cycle the known weight will appear again after it had been removed. If not wait another 10 seconds or until the weight eventually appears. Follow Steps 5 & 6 using a second test weight on the scale. Repeat Steps 5 & 6 using both the rst and second test weight onto the scale. When 0.0 appears remove one of the two weights and conrm this weight appears in Echolog. Munters Corporation, February 2020 QM1601r1A 37 FCC Compliance 7. FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be veried by turning the device o and on, the user is encouraged to eliminate the interference by one or more of the following measures:
Re-orient or re-locate the receiving antenna. Increase the distance between the device and the receiver. Connect the device to an outlet on a circuit dierent from the one that supplies power to the receiver. Consult the dealer or an experienced radio/TV technician. WARNING! Changes or modications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. A distance of at least 20 cm. between the equipment and all persons should be maintained during the operation of the equipment. Une distance d'au moins 20 cm. entre l'quipement et toutes les personnes devraient tre maintenues pendant le fonctionnement de l'quipement 38 QM1601r1A Munters Corporation, February 2020 This page left blank intentionally Munters Corporation, February 2020 QM1601r1A 39 Warranty 8. Warranty and technical assistance Munters products are designed and built to provide reliable and satisfactory performance but cannot be guaranteed free of faults; although they are reliable products they can develop unforeseeable defects and the user must take this into account and arrange adequate emergency or alarm systems if failure to operate could cause damage to the articles for which the Munters plant was required: if this is not done, the user is fully responsible for the damage which they could suer. Munters extends this limited warranty to the rst purchaser and guarantees its products to be free from defects originating in manufacture or materials for one year from the date of delivery, provided that suitable transport, storage, installation and maintenance terms are complied with. The warranty does not apply if the products have been repaired without express authorization from Munters, or repaired in such a way that, in Munters judgment, their performance and reliability have been impaired, or incorrectly installed, or subjected to improper use. The user accepts total responsibility for incorrect use of the products. The warranty on products from outside suppliers tted to the Echo, (for example power supplies, cables, etc.) is limited to the conditions stated by the supplier: all claims must be made in writing within eight days of the discovery of the defect and within 12 months of the delivery of the defective product. Munters has thirty days from the date of receipt in which to take action, and has the right to examine the product at the customers premises or at its own plant (carriage cost to be borne by the customer). Munters at its sole discretion has the option of replacing or repairing, free of charge, products which it considers defective, and will arrange for their dispatch back to the customer carriage paid. In the case of faulty parts of small commercial value which are widely available (such as bolts, etc.) for urgent dispatch, where the cost of carriage would exceed the value of the parts, Munters may authorize the customer exclusively to purchase the replacement parts locally; Munters will reimburse the value of the product at its cost price. Munters will not be liable for costs incurred in demounting the defective part, or the time required to travel to site and the associated travel costs. No agent, employee or dealer is authorized to give any further guarantees or to accept any other liability on Munters behalf in connection with other Munters products, except in writing with the signature of one of the Companys Managers. WARNING: In the interests of improving the quality of its products and services, Munters reserves the right at any time and without prior notice to alter the specications in this manual. 40 QM1601r1A Munters Corporation, February 2020 Chapter 5 Warranty The liability of the manufacturer Munters ceases in the event of:
dismantling the safety devices;
use of unauthorized materials;
inadequate maintenance;
use of non-original spare parts and accessories. Barring specic contractual terms, the following are directly at the users expense:
preparing installation sites;
providing an electricity supply (including the protective equipotential bonding (PE) conductor, in accordance with CEI EN 60204-1, paragraph 8.2), for correctly connecting the equipment to the mains electricity supply;
information supplied with regard to installation;
tools and consumables required for tting and installation;
lubricants necessary for commissioning and maintenance. providing ancillary services appropriate to the requirements of the plant on the basis of the It is mandatory to purchase and use only original spare parts or those recommended by the manufacturer. Dismantling and assembly must be performed by qualied technicians and according to the manufacturers instructions. The use of non-original spare parts or incorrect assembly exonerates the manufacturer from all liability. Requests for technical assistance and spare parts can be made directly to the nearest Munters oce. A full list of contact details can be found on the back page of this manual. Munters Corporation, February 2020 QM1601r1A 41 Echo Barn Kit is developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66. Munters Corporation 2691 Ena Drive Lansing, MI 48917 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078 www.munters.us Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters Corporation Lansing, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 3311, India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia, Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone
+52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endstri Sistemleri A., Phone +90 322 231 1338, USA Munters Corporation, Lansing MI Phone
+1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11 Munters reserves the right to make alterations to specifications, quantities, etc., for production or other reasons, subsequent to publication. Munters AB, 2015 42 QM1601r1A Munters Corporation, February 2020
1 | 731 Signature Authorization Letter | Cover Letter(s) | 115.32 KiB | March 06 2020 |
Date: November 20, 2019 To: Timco Engineering Inc. To Whom It May Concern We hereby authorize Mr. Ilan Cohen of I.T.L. (Product Testing) Ltd (ITL) to sign FORM 731 on our behalf for the following FCC ID application:
FCC ID: 2ATJLECHO Thank you, Wouter Claassens VP Sales Americas and Business Development Munters Corporation 2691 Ena Drive Lansing, MI 48917-2033 U.S.A. Phone: +1 517-676-7070 +1 800-227-2376 Fax: +1 517-676-7078 aghort.info@munters.com www.munters.us
1 | Authorization Letter | Cover Letter(s) | 114.39 KiB | March 06 2020 |
Date: November 20, 2019 To Whom It May Concern We hereby authorize Mr. Ilan Cohen of I.T.L. (Product Testing) Ltd (ITL) to act on our behalf regarding the FCC Certification Process for the following application:
FCC ID: 2ATJLECHO Thank you, Wouter Claassens VP Sales Americas and Business Development Munters Corporation 2691 Ena Drive Lansing, MI 48917-2033 U.S.A. Phone: +1 517-676-7070 +1 800-227-2376 Fax: +1 517-676-7078 aghort.info@munters.com www.munters.us
1 | Confidentiality Request Letter | Cover Letter(s) | 117.19 KiB | March 06 2020 |
Date: November 20, 2019 Federal Communications Commission Authorization and Evaluation Division To: Federal Communications Commission Confidentiality Request regarding application for the FCC certification of FCC ID: 2ATJLECHO Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, we hereby request confidential treatment of information accompanying this application as outlined below:
a. CONF APPENDIX ECHO Partlst.pdf b. CONF APPENDIX ECHO BlkDia.pdf c. CONF APPENDIX ECHO Schem.pdf d. CONF APPENDIX ECHO OpDes.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Thank you, Wouter Claassens VP Sales Americas and Business Development Munters Corporation 2691 Ena Drive Lansing, MI 48917-2033 U.S.A. Phone: +1 517-676-7070 +1 800-227-2376 Fax: +1 517-676-7078 aghort.info@munters.com www.munters.us
1 | Tune Up Procedure | Parts List/Tune Up Info | 113.15 KiB | March 06 2020 |
Date: November 20, 2019 To: Federal Communications Commission FCC ID: 2ATJLECHO No manual tune-up procedure required. Thank you, Wouter Claassens VP Sales Americas and Business Development Munters Corporation 2691 Ena Drive Lansing, MI 48917-2033 U.S.A. Phone: +1 517-676-7070 +1 800-227-2376 Fax: +1 517-676-7078 aghort.info@munters.com www.munters.us
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-03-06 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-03-06
|
||||
1 | Applicant's complete, legal business name |
MUNTERS ISRAEL LTD
|
||||
1 | FCC Registration Number (FRN) |
0028534444
|
||||
1 | Physical Address |
2691 Ena Drive
|
||||
1 |
Lansing, MI
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ATJL
|
||||
1 | Equipment Product Code |
ECHO
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
W**** C******
|
||||
1 | Title |
VP Sales Americas And Business Development
|
||||
1 | Telephone Number |
+1-21********
|
||||
1 | Fax Number |
+9723********
|
||||
1 |
w******@munters.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Poultry House Monitoring Equipment | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports 20 MHz bandwidth modes. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
ITL PRODUCT TESTING LTD
|
||||
1 | Name |
I****** C****
|
||||
1 | Telephone Number |
972-8********
|
||||
1 | Fax Number |
+972 ********
|
||||
1 |
i******@itl.co.il
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.1258900 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC