all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual 01 | Users Manual | 945.09 KiB | May 01 2012 / June 01 2012 | |||
1 |
|
User manual 02 | Users Manual | 1.60 MiB | May 01 2012 / June 01 2012 | |||
1 | Cover Letter(s) | May 01 2012 / June 01 2012 | ||||||
1 | Cover Letter(s) | May 01 2012 / June 01 2012 | ||||||
1 | External Photos | May 01 2012 / June 01 2012 | ||||||
1 | Internal Photos | May 01 2012 / June 01 2012 | ||||||
1 | ID Label/Location Info | May 01 2012 / June 01 2012 | ||||||
1 | Cover Letter(s) | May 01 2012 / June 01 2012 | ||||||
1 | Test Setup Photos | May 01 2012 / June 01 2012 | ||||||
1 | Test Report | May 01 2012 / June 01 2012 |
1 | User manual 01 | Users Manual | 945.09 KiB | May 01 2012 / June 01 2012 |
Service manual For installation, operation and service Panel Reader VP1850 February 2011 / Manual version 1.2 Manual article number 5277027 Preface This manual describes the installation, operation, troubleshooting and maintenance of the VP1850 Panel reader. Read this manual entirely and when installing, carefully follow the instructions step by step as described in the manual. Pictograms Please pay extra attention here. This pictogram indicates an important subject. Version overview Manual version 1.0 / May 2010 First release. Manual version 1.1 / October 2010 Wiring adjusted. Manual version 1.2 / February 2011 IP utility wizard instructions for CD adjusted. This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands VP1850-200PM-00GB-Panel reader Manual version 1.2 Table of contents Preface and Version overview Table of contents Introduction .........................................................................................................................1 1. 1.1. Description ............................................................................................................................1 1.2. Functioning............................................................................................................................1 2. Mounting the VP1850 Panel reader...................................................................................3 3. Starting up operation..........................................................................................................4 3.1. Connecting the VP1850 Panel reader ..................................................................................4 3.2. Setting up the network configuration ....................................................................................5 3.3. Setting up the VP1850 Panel reader software .....................................................................6 4. Operation .............................................................................................................................8 5. Malfunctions and disposal.................................................................................................9 5.1. Trouble shooting ...................................................................................................................9 5.2. Resetting the VP1850 Panel reader ...................................................................................10 6. Maintenance and disposal ...............................................................................................11 6.1. Maintenance........................................................................................................................11 6.2. Disposal ..............................................................................................................................11 Technical specifications..................................................................................12 Appendix A Appendix B Wiring Panel reader .........................................................................................13 Appendix C Corridor requirements.....................................................................................15 VP1850-200PM-00GB-Panel reader Manual version 1.2 1. Introduction The VP1850 Panel reader identifies RFID ear tags attached to individual animals. The identification can be used for registration of the animals that have passed the VP1850 Panel reader unit. A weight scale can optionally be connected to the Panel reader. This device complies with Part 15 of the FCC Rules and to RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1.1. Description The VP1850 Panel reader system consists of a Panel reader unit that is connected to an adaptor, a PC or a network or optionally a weight scale. 2 1 Weight scale 4 OR 3 5 6 Figure 1. Overview VP1850 Panel reader system 1.2. Functioning 1. VP1850 Panel reader unit 2. Adaptor 3. PC 4. Optional Weight scale 5. Blue tooth connection 6. GPS connection The VP1850 Panel reader creates a magnetic field around the antenna that is used to identify the tags on ISO frequency 134.2 kHz. The Panel reader antenna identifies RFID ear tags attached to individual animals that pass the Panel Reader unit. The identification is indicated with five blue burning led lights in the top of the Panel reader. Figure 2. Identification blue led lights VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 1 When an animal is identified in the Panel reader antenna, the responder number will be stored. The responder number will be shown in the web server program. A PC or a network is used to access the web server (and the Internet worldwide). It does not have to be connected all the time. 1. VP1850 Panel reader unit 2. Responder number
(animal identification) 3. Data in web server program 3 2 1 Figure 3. Connection between VP1850 Panel reader and web server program VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 2 2. Mounting the VP1850 Panel reader See Appendix A for technical specifications before mounting. See Appendix C for corridor requirements. Mounting requirements:
1. The Panel reader must be mounted at the side where the ear tags of the animals are attached. 2. The Panel reader must be mounted on a wall close to a stable power supply. 3. The Panel reader must not be mounted close to any iron. Iron will affect the performance of the antenna. 4. The Panel reader must be mounted > 1.5 m. from electrical cables or power supply /
transformers. 5. The Panel reader must not be mounted close to electrical equipment (e.g. a power supply) with background noise. This can disturb the antenna. 6. The Panel reader may not be exposed to direct sunlight. Mount the VP1850 Panel reader unit firmly on a wall or at a (non metal) frame. 1. Drill 10 and at least 50 mm deep holes to mount the Panel reader in the 4 positions indicated in the picture below. 2. Use the bolts that are supplied with the unit to mount the Panel reader. Use the 4 big bolts for a wall or the 4 smaller ones for a metal surface. 2 A 3 3 A B 2 4 B For wall: Bolt, washer, spacer and plug (4x) A. Bolt M8x80 DIN 571 2. Plain washer M8 DIN 9021 3. Spacer 4. Nylon plug 10x50 For metal: Bolt, washer and spacer (4x) B. Bolt M6.3x50 DIN 7504 2. Plain washer M8 DIN 9021 3. Spacer Figure 4. Mounting positions for the VP1850 Panel reader General remark: Dont drill through the Panel reader. This could damage the electronics and affect the functioning of the Panel reader. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 3 3. Starting up operation The VP1850 Panel reader is pre-tuned and ready for use. 3.1. Connecting the VP1850 Panel reader Connect the VP1850 Panel reader to a PC or a weight scale through an RS232 connection or to a PC or router through a LAN (or Bluetooth) connection. The Panel reader is already connected to the adapter through the connector. The adapter is optionally used when connected to a weight scale (depends on weight scale type). See appendix B for a wiring scheme of the Panel reader cable. 1 Weight scale 1. RS232 connection with PC 2. RS232 connection with weight scale or other device and optional adaptor 3. Bluetooth or LAN connection with PC 4. LAN connection with router 3 4 Figure 5. Overview VP1850 Panel reader system to be connected 2 Connect the VP1850 Panel reader to a PC or a network and optionally to a weight scale. Install cables and power supplies / transformers > 1.5 m. from the Panel reader if possible. 3. Connect a PC to the Sub-D connection from the connector if there is no weight scale or connect a PC via the Bluetooth or LAN connection or connect a network via the LAN connection. 4. Optionally connect a weight scale to the Sub-D connection from the connector. 5. Put the adaptor into an electric socket. 6. Check the operation of the Panel reader. Use an extension cable (art. nr 7707037) of 4 meters to extend the Velos Panel reader cable if necessary. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 4 3.2. Setting up the network configuration Make sure the VP1850 Panel reader is connected to the network and is operating. Take the IP Utility wizard CD and run it on the connected PC to set the IP address correctly. 1. Click on the IP utility wizard icon from the IP wizard CD. 2. Turn off the fire wall (in the Control panel - Security centre) and click Next. 3. Click Next. 4. Click on copy advice if this is suggested and click Next. If the VP1850 Panel reader is not found check if the Panel reader is running and if the network is connected correctly. Click Back and try again. Contact a network specialist if necessary. 5. Click Next. The IP address will now be changed and a web server program shortcut will be created on the desktop. Click OK. 6. Click on OK and on Finish. 7. The web server program shortcut is now on the desktop. Click on it to start the program. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 5 3.3. Setting up the VP1850 Panel reader software Click on the web server shortcut icon on the desktop to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard (factory default http://10.10.10.10). 1. Set the clock time in the screen Settings > Clock and press Submit. Press refresh or F5 to get the new value from the Panel reader. 2. Change the output and storage protocol if necessary in the screen Settings > Protocol and press Submit. The output and storage settings will influence the output data that will be send by the RS232 and the Bluetooth every time a number is read. The default and recommended output setting is: ISO extended. ISO: output data send according ISO standards. ISO Extended: output data send according to ISO standards, including timestamp. Output protocol:
Nedap: output data send according to Nedap Velos protocol. For advanced user: In UDP the number is sent real-time. The default and storage settings are: Recognition time 5 and store double tags No. Store double tags Yes: store the identification time of double tags in the same file. Store double tags No: store only the last identification time. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 6 3. Optionally enter a user name and password. Especially when the Panel reader is integrated in a network this is advised. 4. Change the RS232 and Bluetooth settings in the Settings screen if necessary and press Submit. The network settings have been made in 3.2. The default RS232 settings are: Baud rate 9600, Data bits 8, Parity None and Stop bits 1. The default Bluetooth name is BlueMod+B20 %:4a and the default security pin code is 0000. These settings can be changed. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 7 4. Operation The Panel reader web server data program can be opened and operated on a PC. Click on the web server shortcut icon on the desktop to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard (factory default http://10.10.10.10). A list of filenames is shown in the data page. The last created data log file is shown at the top. Click on a filename to look at the content of a file. The data can be downloaded or deleted. Click on download to download the data to another web page. Here you can select and copy data. A new data file is automatically created at midnight and after a power down. Please note: its a static webpage. To see new numbers click refresh or press F5. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 8 5. Malfunctions and disposal 5.1. Trouble shooting Check the operation of the VP1850 Panel reader regularly with (a few) tag(s). Check the actual state of the Panel reader. The Panel reader led lights will show if there are any malfunctions. The Panel reader led lights will show if the system is working correctly or not. Green light Red light Both ON
+ Both OFF
= OK Display VP1850 Panel reader Check the cause of the malfunction and solve it. Problem What/How to check or re-install See 2 2 1 green light on: reduced antenna field caused by some iron. Identification possible but reduced performance. 2 flashing green lights: no correct antenna field caused by a lot of iron. Identification possible but a very much reduced performance. Antenna tuning. Remove the iron from the Panel reader area. Antenna tuning. Remove the iron from the Panel reader area. 1 red light(s) on: identification possible but reduced performance caused by electrical equipment with background noise. Possibly cable or power supply /
transformer < 1.5 m. from the Panel reader. Find source of the background noise in the Panel reader area that disturbs the antenna e.g. a power supply, fluorescent lightning, another antenna or a frequency controller. Delete it or turn it off. 2 red light(s) on: strongly reduced performance caused by a no synchronisation with a nearby HDX reader or electrical equipment with strong electrical background noise. Possibly cable or power supply /
transformer < 1.5 m. from the Panel reader. No identification possible. Blue light not on: no signal or blue tooth pincode not entered correctly. Find source of the background noise in the Panel reader area that disturbs the antenna e.g. a power supply, fluorescent lightning, another antenna or a frequency controller. Delete it or turn it off. Install cables and power supply / transformer > 1.5 m. from the Panel reader if possible. Check the pin code. 3.3 Yellow light not on: no GPS signal in the area or building. If indoors move Panel reader outdoors. If outdoors no GPS signal available. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 9 5.2. Resetting the VP1850 Panel reader If necessary set the VP1850 Panel reader back to its factory defaults:
1. Turn on the power 2. Put a magnet on the spot indicated on the back of the Panel reader with a circle on the sticker and keep it there. A row of blue leds will light up when the magnet is in the correct position. 3. Turn off the power and turn it back on. The row of blue leds will light up again. 4. Remove the magnet from the Panel reader. 5. Turn off the power and turn it back on again. The Panel reader is now set back to its factory defaults. The IP address now is 10.10.10.10 again like in the beginning. See chapter 3 to start up the operation again by setting the network configuration and the software settings. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 10 6. Maintenance and disposal 6.1. Maintenance Check the operation of the VP1850 Panel reader regularly. No regular maintenance is required. The Panel reader can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids. 6.2. Disposal At discard dispose of materials from the Panel reader in accordance with the current environmental rules of the state or local governing authorities. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 11 Appendix A Technical specifications Measurements VP1850 Panel reader Total height Total width Depth 595 mm 395 mm 30 mm Specifications for transport / installation Weight VP1850 Panel reader Electrical supply Main supply Frequency Input voltage (use Nedap power supply) Input current (mA) depends on input voltage (without buzzer) Environmental Operating temperatures Transport / storage temperatures Humidity (rh) Enclosure protection class (when cover and cables installed correctly) The Panel reader may not be exposed to direct sunlight. The Panel reader must always be transported and stored dry and frost-free. 6.2 kg 100V - 240V 50 60 Hz 12 48 V DC 1 0.5 A
- 10C / + 45C
- 40C / + 70C 45C / 85%
IP67 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 12 Appendix B Wiring Panel reader 1 2 Wiring scheme Panel reader cable 1. Connector number Velos Panel reader cable ( art.nr.7707029) Red Black Blue Blue / White Shield Orange Orange / White Green Green / White
Tx+
Tx-
Rx+
Rx-
TxD RxD
(12 48 V) Ethernet 10 Mb Tx+
Ethernet 10 Mb Tx-
Shielding Ethernet 10 Mb Rx+
Ethernet 10 Mb Rx-
RS232 TxD RS232 RxD Wiring scheme Panel reader cable 2. Connector number Velos Panel reader cable ( art.nr.7707029) Not connected Minus
Red Black Blue Blue / White Shield Orange Orange / White Green Green / White FDX in F-synchronization FDX in FDX out F-synchronization FDX out HDX HDX Shielding HDX synchronization HDX synchronization Output Buzzer -
Output Buzzer + (10 - 24 V) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 13 Wiring more than one Panel reader. 2 >2m 2 >2m 2 1 2 3 Connect all cables with number 2 to a Connector block. Connect the 1st blue-white wire and the 2nd and 3rd blue wires to one connector point. Connect all 3 black, shielding, orange and orange-white wires, each colour to one connector block point. Wiring scheme Panel reader cable 2. Connector number Velos Panel reader cable ( art.nr.7707029) Not connected Minus FDX in F-synchronization FDX in FDX out F-synchronization FDX out
1 2 3 4 5 6 7 8 Red Black Blue Blue / White Shield Orange Orange / White Green Green / White HDX HDX Shielding HDX synchronization HDX synchronization Output Buzzer -
Output Buzzer + (10 - 24 V) VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 14 Appendix C Corridor requirements The maximum corridor width at the Panel reader location will be different for each animal sort and breed. Make sure the corridor is not too wide at the Panel reader location. The maximum width of the corridor is essential to achieve a proper working system. Animals should never be able to pass each other, turn around or walk in the wrong direction. Maximum width 1 animal wide IN g n o l l i a m n a 1 h g n e t l m u m n M i i Maximum corridor entrance width:
Allow passage of 1 animal at the time. Keep the corridor as narrow as possible. RFID Eartags : Attach all ear tags on same side of animals (left in this example). The antenna must be mounted at the side where the tag is attached. The identification distance of the antenna field The identification distance of the antenna varies per installation. It depends on the iron and the background noise in the panel reader area. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 15 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 16
1 | User manual 02 | Users Manual | 1.60 MiB | May 01 2012 / June 01 2012 |
Panel Reader VP1850 Manual article number 5278384 March 2011 / Manual version 1.2 1 Thank you for purchasing a high quality VP1850 Panel Reader. VP1850-200PM-00GB-Panel reader Manual version 1.2 Preface This manual describes the installation, operation, troubleshooting and maintenance of the VP1850 Panel reader. Read this manual entirely and when installing, carefully follow the instructions step by step as described in the manual. Pictograms Please pay extra attention here. This pictogram indicates an important subject. First release. Version overview Manual version 1.2 / March 2011 This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. www.tepari.com VP1850-200PM-00GB-Panel reader Manual version 1.2 Table of contents Preface and Version overview Table of contents 1. Introduction .........................................................................................................................1 1.1. Description ............................................................................................................................1 1.2. Functioning............................................................................................................................1 2. Mounting the VP1850 Panel reader...................................................................................3 3. Starting up operation..........................................................................................................4 3.1. Connecting the VP1850 Panel reader ..................................................................................4 3.2. Setting up the network configuration.....................................................................................5 3.3. Setting up the VP1850 Panel reader software......................................................................6 4. Operation .............................................................................................................................8 5. Malfunctions and disposal.................................................................................................9 5.1. Trouble shooting ...................................................................................................................9 5.2. Resetting the VP1850 Panel reader ...................................................................................10 6. Maintenance and disposal ...............................................................................................11 6.1. Maintenance........................................................................................................................11 6.2. Disposal ..............................................................................................................................11 Appendix A Technical specifications..................................................................................12 Appendix B Wiring Panel reader .........................................................................................13 Appendix C Corridor requirements.....................................................................................15 VP1850-200PM-00GB-Panel reader Manual version 1.2 1. Introduction The VP1850 Panel reader identifies RFID ear tags attached to individual animals. The identification can be used for registration of the animals that have passed the VP1850 Panel reader unit. A weight scale can optionally be connected to the Panel reader. This device complies with Part 15 of the FCC Rules and to RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Description 1.1. The VP1850 Panel reader system consists of a Panel reader unit that is connected to an adaptor, a PC or a network or optionally a weight scale. 2 1 Weight scale 4 OR 3 5 6 Figure 1. Overview VP1850 Panel reader system 1.2. Functioning 1. VP1850 Panel reader unit 2. Adaptor 3. PC 4. Optional Weight scale 5. Blue tooth connection 6. GPS connection The VP1850 Panel reader creates a magnetic field around the antenna that is used to identify the tags on ISO frequency 134.2 kHz. The Panel reader antenna identifies RFID ear tags attached to individual animals that pass the Panel Reader unit. The identification is indicated with five blue burning led lights in the top of the Panel reader. Figure 2. Identification blue led lights VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 1 When an animal is identified in the Panel reader antenna, the responder number will be stored. The responder number will be shown in the web server program. A PC or a network is used to access the web server (and the Internet worldwide). It does not have to be connected all the time. 1. VP1850 Panel reader unit 2. Responder number
(animal identification) 3. Data in web server program 3 2 1 Figure 3. Connection between VP1850 Panel reader and web server program VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 2 2. Mounting the VP1850 Panel reader See Appendix A for technical specifications before mounting. See Appendix C for corridor requirements. Mounting requirements:
1. The Panel reader must be mounted at the side where the ear tags of the animals are attached. 2. The Panel reader must be mounted on a wall close to a stable power supply. 3. The Panel reader must not be mounted close to any iron. Iron will affect the performance of the antenna. 4. The Panel reader must be mounted > 1.5 m. from electrical cables or power supply /
transformers. 5. The Panel reader must not be mounted close to electrical equipment (e.g. a power supply) with background noise. This can disturb the antenna. 6. The Panel reader may not be exposed to direct sunlight. Mount the VP1850 Panel reader unit firmly on a wall or at a (non metal) frame. 1. Drill 10 and at least 50 mm deep holes to mount the Panel reader in the 4 positions indicated in the picture below. 2. Use the bolts that are supplied with the unit to mount the Panel reader. Use the 4 big bolts for a wall or the 4 smaller ones for a metal surface. 3 3 2 A A B 2 4 B For wall: Bolt, washer, spacer and plug (4x) A. Bolt M8x80 DIN 571 2. Plain washer M8 DIN 9021 3. Spacer 4. Nylon plug 10x50 For metal: Bolt, washer and spacer (4x) B. Bolt M6.3x50 DIN 7504 2. Plain washer M8 DIN 9021 3. Spacer Figure 4. Mounting positions for the VP1850 Panel reader General remark: Dont drill through the Panel reader. This could damage the electronics and affect the functioning of the Panel reader. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 3 3. 3.1. Starting up operation The VP1850 Panel reader is pre-tuned and ready for use. Connecting the VP1850 Panel reader Connect the VP1850 Panel reader to a PC or a weight scale through an RS232 connection or to a PC or router through a LAN (or Bluetooth) connection. The Panel reader is already connected to the adapter through the connector. The adapter is optionally used when connected to a weight scale (depends on weight scale type). See appendix B for a wiring scheme of the Panel reader cable. 1 Weight scale 1. RS232 connection with PC 2. RS232 connection with weight scale or other device and optional adaptor 3. Bluetooth or LAN connection with PC 4. LAN connection with router 3 4 Figure 5. Overview VP1850 Panel reader system to be connected 2 Connect the VP1850 Panel reader to a PC or a network and optionally to a weight scale. Install cables and power supplies / transformers > 1.5 m. from the Panel reader if possible. 1. Connect a PC to the Sub-D connection from the connector if there is no weight scale or connect a PC via the Bluetooth or LAN connection or connect a network via the LAN connection. 2. Optionally connect a weight scale to the Sub-D connection from the connector. 3. Put the adaptor into an electric socket. 4. Check the operation of the Panel reader. Use an extension cable (art. nr 7707037) of 4 meters to extend the Velos Panel reader cable if necessary. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 4 3.2. Setting up the network configuration Make sure the VP1850 Panel reader is connected to the network and is operating. Take the IP Utility wizard CD and run it on the connected PC to set the IP address correctly. 5. Click on the IP utility wizard icon from the IP wizard CD. 6. Turn off the fire wall (in the Control panel - Security centre) and click Next. 7. Click Next. 8. Click on copy advice if this is suggested and click Next. If the VP1850 Panel reader is not found check if the Panel reader is running and if the network is connected correctly. Click Back and try again. Contact a network specialist if necessary. 9. Click Next. The IP address will now be changed and a web server program shortcut will be created on the desktop. Click OK. 10. Click on OK and on Finish. 11. The web server program shortcut is now on the desktop. Click on it to start the program. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 5 3.3. Setting up the VP1850 Panel reader software Click on the web server shortcut icon on the desktop to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard (factory default http://10.10.10.10). 1. Set the clock time in the screen Settings > Clock and press Submit. Press refresh or F5 to get the new value from the Panel reader. 2. Change the output and storage protocol if necessary in the screen Settings > Protocol and press Submit. The output and storage settings will influence the output data that will be send by the RS232 and the Bluetooth every time a number is read. The default and recommended output setting is: ISO extended. ISO: output data send according ISO standards. ISO Extended: output data send according to ISO standards, including timestamp. Output protocol:
Nedap: output data send according to Nedap Velos protocol. For advanced user: In UDP the number is sent real-time. The default and storage settings are: Recognition time 5 and store double tags No. Store double tags Yes: store the identification time of double tags in the same file. Store double tags No: store only the last identification time. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 6 3. Optionally enter a user name and password. Especially when the Panel reader is integrated in a network this is advised. 4. Change the RS232 and Bluetooth settings in the Settings screen if necessary and press Submit. The network settings have been made in 3.2. The default RS232 settings are: Baud rate 9600, Data bits 8, Parity None and Stop bits 1. The default Bluetooth name is BlueMod+B20 %:4a and the default security pin code is 0000. These settings can be changed. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 7 4. Operation The Panel reader web server data program can be opened and operated on a PC. Click on the web server shortcut icon on the desktop to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard (factory default http://10.10.10.10). A list of filenames is shown in the data page. The last created data log file is shown at the top. Click on a filename to look at the content of a file. The data can be downloaded or deleted. Click on download to download the data to another web page. Here you can select and copy data. A new data file is automatically created at midnight and after a power down. Please note: its a static webpage. To see new numbers click refresh or press F5. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 8 5. 5.1. Malfunctions and disposal Trouble shooting Check the operation of the VP1850 Panel reader regularly with (a few) tag(s). Check the actual state of the Panel reader. The Panel reader led lights will show if there are any malfunctions. The Panel reader led lights will show if the system is working correctly or not. Display VP1850 Panel reader Green light Red light Both ON
+ Both OFF
= OK Check the cause of the malfunction and solve it. Problem What/How to check or re-install See 2 2 1 green light on: reduced antenna field caused by some iron. Identification possible but reduced performance. 2 flashing green lights: no correct antenna field caused by a lot of iron. Identification possible but a very much reduced performance. Antenna tuning. Remove the iron from the Panel reader area. Antenna tuning. Remove the iron from the Panel reader area. 1 red light(s) on: identification possible but reduced performance caused by electrical equipment with background noise. Possibly cable or power supply /
transformer < 1.5 m. from the Panel reader. Find source of the background noise in the Panel reader area that disturbs the antenna e.g. a power supply, fluorescent lightning, another antenna or a frequency controller. Delete it or turn it off. 2 red light(s) on: strongly reduced performance caused by a no synchronisation with a nearby HDX reader or electrical equipment with strong electrical background noise. Possibly cable or power supply /
transformer < 1.5 m. from the Panel reader. No identification possible. Blue light not on: no signal or blue tooth pincode not entered correctly. Find source of the background noise in the Panel reader area that disturbs the antenna e.g. a power supply, fluorescent lightning, another antenna or a frequency controller. Delete it or turn it off. Install cables and power supply / transformer > 1.5 m. from the Panel reader if possible. Check the pin code. 3.3 Yellow light not on: no GPS signal in the area or building. If indoors move Panel reader outdoors. If outdoors no GPS signal available. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 9 5.2. Resetting the VP1850 Panel reader If necessary set the VP1850 Panel reader back to its factory defaults:
1. Turn on the power 2. Put a magnet on the spot indicated on the back of the Panel reader with a circle on the sticker and keep it there. A row of blue leds will light up when the magnet is in the correct position. 3. Turn off the power and turn it back on. The row of blue leds will light up again. 4. Remove the magnet from the Panel reader. 5. Turn off the power and turn it back on again. The Panel reader is now set back to its factory defaults. The IP address now is 10.10.10.10 again like in the beginning. See chapter 3 to start up the operation again by setting the network configuration and the software settings. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 10 Maintenance and disposal 6. 6.1. Maintenance Check the operation of the VP1850 Panel reader regularly. No regular maintenance is required. The Panel reader can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids. Disposal 6.2. At discard dispose of materials from the Panel reader in accordance with the current environmental rules of the state or local governing authorities. VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 11 Appendix A Technical specifications Measurements VP1850 Panel reader Total height Total width Depth 595 mm 395 mm 30 mm Specifications for transport / installation Weight VP1850 Panel reader Electrical supply Main supply Frequency Input voltage (use Nedap power supply) Input current (mA) depends on input voltage (without buzzer) Environmental Operating temperatures Transport / storage temperatures Humidity (rh) Enclosure protection class (when cover and cables installed correctly) The Panel reader may not be exposed to direct sunlight. The Panel reader must always be transported and stored dry and frost-free. 6.2 kg 100V - 240V 50 60 Hz 12 48 V DC 1 0.5 A
- 10C / + 45C
- 40C / + 70C 45C / 85%
IP67 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 12 Appendix B Wiring Panel reader 1 2 Wiring scheme Panel reader cable 1. Connector number Velos Panel reader cable ( art.nr.7707029) Red Black Blue Blue / White Shield Orange Orange / White Green Green / White
Tx+
Tx-
Rx+
Rx-
TxD RxD
(12 48 V) Ethernet 10 Mb Tx+
Ethernet 10 Mb Tx-
Shielding Ethernet 10 Mb Rx+
Ethernet 10 Mb Rx-
RS232 TxD RS232 RxD Wiring scheme Panel reader cable 2. Connector number Velos Panel reader cable ( art.nr.7707029) Not connected Minus
Red Black Blue Blue / White Shield Orange Orange / White Green Green / White FDX in F-synchronization FDX in FDX out F-synchronization FDX out HDX HDX Shielding HDX synchronization HDX synchronization Output Buzzer -
Output Buzzer + (10 - 24 V) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 13 Wiring more than one Panel reader. 2 >2m 2 >2m 2 1 2 3 Connect all cables with number 2 to a Connector block. Connect the 1st blue-white wire and the 2nd and 3rd blue wires to one connector point. Connect all 3 black, shielding, orange and orange-white wires, each colour to one connector block point. Wiring scheme Panel reader cable 2. Connector number Velos Panel reader cable ( art.nr.7707029) Not connected Minus FDX in F-synchronization FDX in FDX out F-synchronization FDX out
1 2 3 4 5 6 7 8 Red Black Blue Blue / White Shield Orange Orange / White Green Green / White HDX HDX Shielding HDX synchronization HDX synchronization Output Buzzer -
Output Buzzer + (10 - 24 V) VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 14 Appendix C Corridor requirements The maximum corridor width at the Panel reader location will be different for each animal sort and breed. Make sure the corridor is not too wide at the Panel reader location. The maximum width of the corridor is essential to achieve a proper working system. Animals should never be able to pass each other, turn around or walk in the wrong direction. Maximum width 1 animal wide IN Maximum corridor entrance width:
Allow passage of 1 animal at the time. Keep the corridor as narrow as possible. RFID Eartags : Attach all ear tags on same side of animals (left in this example). The antenna must be mounted at the side where the tag is attached. The identification distance of the antenna field The identification distance of the antenna varies per installation. It depends on the iron and the background noise in the panel reader area. g n o l l i a m n a 1 h t g n e l m u m n M i i VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 15 VP1850-200PM-00GB-Panel reader Manual version 1.2 / Page 16 Contact Us Te Pari Products Ltd PO Box 25 67 Humber Street Oamaru 9444, New Zealand Phone: 0800 837 274 or 03 433 0077 Fax: 03 434 8859 Email: sales@tepari.com Web: www.tepari.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-01-06 | 0.1342 ~ 0.1342 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-01-06
|
||||
1 | Applicant's complete, legal business name |
N. V. Nederlandsche Apparatenfabriek NEDAP
|
||||
1 | FCC Registration Number (FRN) |
0007696149
|
||||
1 | Physical Address |
Parallelweg 2
|
||||
1 |
Groenlo, N/A 7141 DC
|
|||||
1 |
Netherlands
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
CGD
|
||||
1 | Equipment Product Code |
VP1850
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R**** H****
|
||||
1 | Title |
Approbation Officer
|
||||
1 | Telephone Number |
00315********
|
||||
1 | Fax Number |
00315********
|
||||
1 |
r******@nedap.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Inductive Card Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV Rheinland Nederland B.V.
|
||||
1 | Name |
R**** v****
|
||||
1 | Telephone Number |
31-08********
|
||||
1 | Fax Number |
31-59********
|
||||
1 |
r******@nl.tuv.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.13420000 | 0.13420000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC