submitted | available | document details (if available) | source link |
---|---|---|---|
Adobe PDF Library 10.0.1 |
various | Users Manual | Users Manual | 2.56 MiB |
Smart Deactivator Manual UL manual smart deactivator according to ul regulations SMART DEAC Mounting SMART DEAC Wiring Appendix 1 : Quick Reference Technical Support Email:
support-eas@nedap.com Postal address:
N.V. Nederlandsche Apparatenfabriek NEDAP, Parallelweg 2, 7141DC, Groenlo, The Netherlands Safety precautions:
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED NEDAP SERVICE PERSONNEL. EN 50419:2005 This European Standard specifies a marking of electrical and electronic equipment in accordance with Article 11(2) of Directive 2002/96/
EC (WEEE); This is in addition to the marking requirement in Article 10(3) of this Directive which requires producers to mark electrical and electronic equipment put on the market after 13 August 2005 with a crossed-out wheeled bin symbol. that applies to electrical and electronic equipment falling under Annex IA of Directive 2002/96/EC, provided the equipment concerned is not part of another type of equipment that does not fall within the scope of this Directive. Annex IB of Directive 2002/96/EC contains an indicative list of the products, which fall under the categories set out in Annex IA of this Directive;
that serves to clearly identify the producer of the equipment and that the equipment has been put on the market after 13 August 2005. 2013 N.V. Nederlandsche Apparatenfabriek NEDAP:
The software / hardware described in this book / file is furnished under a license agreement and may be used only in accordance with the terms of the agreement. Copyright Notice:
All Rights Reserved. Any technical documentation that is made available by N.V. Nederlandsche Apparatenfabriek NEDAP is the copyrighted work of N.V. Nederlandsche Apparatenfabriek Nedap and is owned by N.V. Nederlandsche Apparatenfabriek Nedap. 2 Table of content 1 2 3 4 5 6 Introduction System overview Installation instructions Regulatory declaration Specifications SMART DEAC Appendix 1 4 5 6 7 8 9 3 1 Introduction N.V. Nederlandsche Apparatenfabriek Nedap, hereafter called Nedap, is manufacturer of one of the most reliable and scalable EAS Systems in the market today. With a Nedap EAS system you are able to reduce shoplifting costs to a minimum in combination with Nedaps tagging solutions. The Nedap Smart Deactivator, also called SMART DEAC, is meant for deactivation of disposable 8.2MHz RF labels. It detects RF labels and hard tags in range of the deactivator antenna and tries to deactivate the rf labels until they are deactivated. Some of the Smart Deactivator advantages are:
1. Constant optimal deactivation distance, independent of the tag frequency between 7.2 8.8 MHz 2. Deactivation behavior programmable with switches 3. Detect only Mode 4. Deactivation on input 5. Forced deactivation on input 6. Short repeating acoustical feedback for successful deactivation, continuous beep when deactivation is unsuccessful or when a hard tag is detected. 7. Prepared for connectivity in RS485 bus structure 8. Sends only a deactivation burst when a tag is detected; Low energy consumption 9. Through air synchronization with Nedap OS/T systems and other SMARTDEAC s The SMART DEAC produces an acoustic and visual signal when it detects and / or deactivates an operating RF label or hard tag. SMART DEAC ANTENNA 265x265 ANTENNA 275x275 4 2 System overview 1 4 7 Power Adapter Nedap Part.no.: 9651802 RS485 communication 5 6 Input Output LED Nedap Part.no.: 9563652 SMART DEAC Nedap Part.no. 9937676 2 Antenna Model: SDA-265x265 Nedap Part.no.: 9564101 or Model: DAPL-275x275 Nedap Part.no.: 9911537 3 Figure 1 Functional system overview The SMART DEAC system (Figure 1) consists of the following components:
1. AC/DC Power adapter Wall Mount 100 240 VAC / 12 VDC Nedap Part.no.: (9551802) 2. Smart Deactivator electronics (9937676) 3. Antenna including cable - Model: SDA-265x265 (9564101) or Model: DAPL-275x275 (9911537) 4. RS485 connection to communicate with the SMART DEAC 5. Input for functionality to be defined 6. Output for functionality to be defined 7. LED for visual indication (9563652) The SMART DEAC system is plug & play. You only have to follow the next steps:
Install the Smart Deactivator system according the instructions;
Power up the Smart Deactivator system;
Check the functionality; by deactivating a RF label above the antenna and check it for a audio signal. Call Nedap EAS Support for quick hands-on problem solution in case of unforeseen trouble
(see Technical Support on page 2) 5 3 Installation instructions The SMART DEAC electronics unit must be powered with a NEC class2 type power source like the NEDAP AC/DC power adapter 100~240Vac/12V dc NEDAP part number 9651802. Always place the unit near a power outlet (less than 1 meter / 3.3 feet ), the power outlet should be easily accessible, also after installation. All the outputs from the SMART DEAC are NEC class2 outputs, output voltages will be 12Vdc or less. The inputs may only be connected to class2 powered system. The SMARTDEAC must be mounted on a solid, nonflammable surface, using all mounting holes and proper mounting material, according to local regulations. All wiring should be done according to local regulations. External LED An external LED can be connected to the connector pins marked LED + and -. We recommend the use of an UL recognized LED like the APEM red panel mount indicator led type Q14F1CXXR02.
(V_forward 1,6v +/-10% and I_forward max. 20mA) The LED output is current limited and short-circuit protected. 6 4 Regulatory declaration Compliance statements (part15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Warning (part15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This in particular is applicable for the antenna which can be delivered with the SMART DEAC System. RF Exposure (OET Bulletin 65) To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm / 8 separation distance between the antenna and all persons. Information to the User (Part 15.106(b)) Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on , the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult your local Nedap Business Partner or
- Consult the dealer of the radio communication device(s) or an experienced radio/TV technician for help. 7 5 Specifications SMART DEAC Enviromental Description Material Construction Protection Class Operating frequency Operational temperature Storage temperature Relative Humidity Operating Distance Aluminium IP20 Min. 7.5 MHz 0 C / 32 F
-10 C / 14 F 20 %
Input Requirements and electrical specifications Description Min. 90 VAC 0.35 A 47 Hz Input Voltage Input Current Line Frequency Operation Voltage Power Regulations Safety approvals of the Power Adapter cULus according to UL/CSA 60950-1 CB according to IEC60950-1 TUV EN60950-1 (2006) NEC Class 2 CE Europe according to EN300330 Japan PSE Typical 8.2 MHz 0.3 m / 12 Typical 100-240
-
50-60 Hz 3 W Max. 8.8 MHz 40 C / 104 F
+70 C / 158 F 90 %
Condition non-condensing Tag-dependant Max. 264 VAC 0.7 A 63 Hz Condition Full Range; 50/60Hz 264 VAC - 90 VAC
-
230 VAC 50Hz Telecom system approval Canada IC according to RSS210 IC ID:1444A-SMARTDEAC US according to FCC Part 15 FCC ID:CGDSMARTDEAC CE according to EN300330 Japan pending In compliance with Human exposure assessment according to:
ICNIRP Guidelines IEEE C95.1 EN62369-1 and EN50364 RSS102 ARIB STD-38 IEC62369-1 Electromagnetic compatibility EN 301 489 (Emission according to EN55022) CISPR 22 IEC 61000-6-2 IEC 61000-6-3 8 6 Appendix 1 Deactivator Antenna 265x265 Deactivator Antenna 265 x 265 (cable length 1600 mm) 02 Bottom mount 01 Table 4x , not included 4,5 (4x) 0 5 1 5 6 2 4,5 (4x) 0 5 1 5 6 2 150 265 150 265 GROENLO THE NETHERLANDS dsgn
: CB date
: 27 February 2014 12:08 PM quick reference : antenna 265x265 Copyright by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. rev
: A article no
: 9741704 page
: 1 of 1 drawing
: T9741704-45.01 9 Smart Deactivator 1x Smart Deactivator including power supply 1x Antenna connector set 1x Power Supply 1x Connector cover 02 Connect deactivator antenna to antenna connector to deactivator antenna ANT1 ANT2 Tie Wrap 6
. 1 3 1 ANT Antenna wire 1 Antenna wire 2 ANT GND Ground GND Ground 03 Connect deactivator antenna to Smart Deactivator 01 Mount housing to solid surface 0 1 5 2
. 8 9 0 1 3
. 5 7 1 5
. 0 4 5
. 4 106 14.5 56 86.6 04 Connect to power 100-240V 05 Beeper sound volume 06 Beeper sound (Standard mode) deactivation detection GROENLO - HOLLAND description:
quick ref. Smart Deactivator | art. no. 9200002 Copyright by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. drw: CB 2013/05/29 chk:
doc. article no: 5276802 Rev. : B.03 sheet: 45.01 of 1 drawing: T9937-676 10
) s g n i t t e s h c t i w s m a r g o r P e e S
(
. t n e r e f f i d e b n a c r u o i v a h e b D E L
, s g n i t t e s h c t i i w s p d n o g n d n e p e D i
) e d o m d r a d n a t S
(
s e h s a 3 d e t a v i t c a e d l e b a L
) e d o m d r a d n a t S
(
h s a 1 d e t c e t e d l e b a L
=
r e w o P
=
D E L t u p t u O
=
D E L s u t a t S
=
s D E L s u t a t S n e e r G d e R e g n a r O w o l l e Y s D E L s u t a t S 8 7 6 5 4 3 2 1 e d i s r o t c e n n o C d e s u t o n n o i t a v i t c a e d r e t f a e s l u p h g H i n o i t a v i t c a e d r e t f a w o l l a n g i s t u p n i t a h g H i n o i t c e t e d r e t f a e s l u p h g H i h s a l F n o i t c e t e d r e t f a e s l u p h g H i n o i t a v i t c a e d g n i r u d h g H i 5 8 4 S R n o i t a n m r e T e n L
=
i i 1 1 s s e r d d A w o L
=
4 8 7 6 5 4 3 2 1 r o t a v i t c a e D
-
t r a m S e s n e S
!
h t i 7 3 i 2 r o t a v i t c a e D
-
t r a m S 1 r o t a v i t c a e D
-
t r a m S 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 5 8 4 S R n o i t a n m r e T e n L
=
i i 1 i n o i t a n m r e T e n L o N
=
i 1 2 s s e r d d A h g H
=
i 4 1 s s e r d d A w o L
=
4 2 r o t a v i t c a e D 1 r o t a v i t c a e D
-
t r a m S
-
t r a m S 7 3 i e d i s r o t c e n n o c a n n e t n A 3 1 4 1 S S
+
D N G r o t a v i t c a e d t r a m S 5 8 4 S R
+
B A
-
s o n e R 5 8 4 S R V 2 1
+
A B D N G w e s u r o f y l n o s g n i t t e S 6
. 7 V
>
:
n o i s r e V A 1 5 3
-
M V 3 G 1 C O t u p t u O e t a t S d i l o S C D V 2 1
+
r o t c e n n o C r e w o P d n u o r G r o t c e n n o c r e w o P n o i t a v i t c a e d t a x 3 h s a l l i w D E L e h T
. n o i t c e t e d n o e c n o d n a o t
, e r a w t f o s d n a r e t r e v n o c 5 8 4 S R l a i c e p s a g n i s u y b
, e l b i s s o p s i t I
. s g n i t t e s e m o s t s u d a j t u p t u O e t a t S d i l o S V 2 1
-
5
+
r o t c e n n o C t u p t u O D E L
-
r o t c e n n o C t u p t u O D E L n o m m o C t u p t u O n e p O l a m r o N e d o h t a K t u p n I e d o n A t u p n I
+
A r o t c e n n o C 5 8 4 S R B r o t c e n n o C 5 8 4 S R
-
D N G V 2 1
+
+
D E L
-
D E L C t u O O N t u O A p n I K p n I V 2 1
+
A 5 8 4 S R B 5 8 4 S R D N G
)
-
(
e d o h t a K t u p n I
)
+
(
e d o n A n o i t c e t e d s d n o c e s 0 1 r e t f a h g H i d e s u t o n n o i t c e t e d s d n o c e s 0 1 r e t f a h g H i n o i t c e t e d r e t f a w o L h s a l F n o i t a v i t c a e d r e t f a w o L l a n g i s t u p n i t a h g H i n o i t a v i t c a e d g n i r u d h g H i w o l l e Y D E L e g n a r O D E L e g n a r O D E L w o l l e Y D E L w o l l e Y D E L e g n a r O D E L w o l l e Y D E L n o i t c e t e d f o s d n o c e s 0 1 r e t f a t u p t u O e d o m y l n o t c e t e D 5 8 4 S R n o i t a n m r e T e n L i i
) t i n u f o m o t t o b n o l e b a l e d o m d r a d n a t S n o i s r e v
,
. 8 6 v n o i s r e v t s n g e r n r u i t c t
(
e s g s n h i t t c e t s i w h c S t i w m S a m r a g r g o o r r P P 8 7 6 5 4 3 2 1 e g n a r O D E L l a n g i s t u p n s d n o c e s 0 9 i r e t f a s d n o c e s 0 9 r o f
, n o i t a v i t c a e d d e c r o F w o l l e Y D E L e g n a r O D E L w o l l e Y D E L e g n a r O D E L e g n a r O D E L w o l l e Y D E L w o l l e Y D E L e g n a r O D E L g n i l l
) 3
. 6
>
e r a w t f o s
(
i h g h s i t u p n i f i y l n o n o i t a v i t c a e D
) 4 6
.
>
e r a w t f o S
(
y t i v i t i s n e s d r a d n a t S
=
y t i v i t i s n e s w o L
=
w o L h g H i e d o m d r a d n a t S
-
d e t r e v n i t u p t u o g n i t n u o C d e t r e v n i t u p t u O
-
y l n o t c e t e D l e m u o v r e z z u b r o f h c t i w s s a d e s u t u p n I o r t n o C n o i t c a s n a r T
-
e d o m L L D
) 0
. 7 V e r a w t f o s
(
8 7 6 5 4 3 2 1
) d r a d n a t s
(
1 s s e r d d A w o l
=
4 2 s s e r d d A h g h
=
i 4
) 0
. 7 V e r a w t f o s
(
5
. 7 V
>
:
n o i s r e V 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 2 3 4 5 6 7 8 9 0 1 1 1 2 1 11 1 v
-
4 1 0 2 parallelweg 2d nl-7141 dc groenlo the netherlands t f e i
+31 (0) 544 471555
+31 (0) 544 465814 info-rs@nedap.com www.nedap-retail.com
This product uses the FCC Data API but is not endorsed or certified by the FCC