E D C B A E D C B A
!D Top height max. 250 cm
!D Top mounting template for ceiling The !D top is most stable when the wires form a broader basis (see picture on the right). To make this mounting template more rigid use the cardboard packaging of the !D top steps for mounting !D Top on the ceiling 1. determine the position of the !D top in store 2. measure the height between !D top and ceiling 3. nd the corresponding mounting holes on this 4. position this template to the ceiling and mark the four mounting holes (pierce through the paper) 5. drill the holes, connect the cables and the !D top template, closest to the measured height h height max. 250 cm height max. 200 cm height max. 200 cm height max. 150 cm height max. 150 cm height max. 100 cm height max. 100 cm height max. 50 cm height max. 25 cm height max. 50 cm height max. 25 cm height max. 25 cm height max. 50 cm height max. 25 cm height max. 50 cm height max. 100 cm height max. 100 cm height max. 150 cm height max. 150 cm height max. 200 cm height max. 200 cm height max. 250 cm height max. 250 cm a 1 9 2
1 4 7 9 t
. o n g n w a r d i 1 9 2 1 4 7 9
. o n t r a p 3x Tie-wrap 2x Bracket (wall mounting) 1x Poster
Ref.Nr. A REV. YYYY-MM-DD DATE Documentation released DESCRIPTION ROUGHNESS ACC. ISO 1302 in M N/A DESCRIPTION ISO A GROENLO HOLLAND GENERAL TOLERANCES SCALE:
FORMAT:
DIM. IN MM 1:5 A3 LIN. 0.2 ANG. 1
APPROVED YYYY-MM-DD YYYY-MM-DD YYYY-MM-DD DSGN:
DRW:
CHCK:
ARTICLE NUMBER REV. 1 2 1x !D Top 3 4 5 6 4x Mounting set 7 9954139 N/A Copyright (c) by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. SHEET:
DRAWING:
A.01 10.01 OF 1 N/A 8 dimensions remove cover
. 6 2
m m 5 6 5 6 500mm / 1.6ft 500 198.5mm / 7.8 198,5 1 1 3
. 3
5 m 4 8 m
, 5
. 4 8 1 5 2 6
. 4 0 1 5
6 m 2 m 5 6 2 8 50(4x) 35(4x) 7(4x) 7 4(8x) 8 7(4x)
) x 4
8 5 DETAIL A SCALE 1 : 2 3 7 4 8 5 6 F 900mm / 3ft 900 E distance between antennas 7 7 5 Holes, for excample:
- Fixing bracket at the ceiling
- Using wire rod(s) For hanging on the antenna with hook (for excample) D 196,5 recommended - 2.0m/6.6ft absolute max. - 2.4m/7.9ft 6,5(3x)
=150=
Ref.Nr. A REV. YYYY-MM-DD DATE ROUGHNESS ACC. ISO 1302 in M N/A DESCRIPTION ISO A Documentation released DESCRIPTION floor GROENLO HOLLAND GENERAL TOLERANCES SCALE:
FORMAT:
DIM. IN MM 1:5 A3 LIN. 0.2 ANG. 1
APPROVED YYYY-MM-DD YYYY-MM-DD YYYY-MM-DD DSGN:
DRW:
CHCK:
ARTICLE NUMBER REV. 5 3 0 5 recommended - 3.0m/9.8ft absolute max. - 3.5m/11.5ft C B
Ref.Nr. A REV. YYYY-MM-DD DATE Documentation released DESCRIPTION GROENLO HOLLAND GENERAL TOLERANCES SCALE:
FORMAT:
DIM. IN MM 1:5 A3 LIN. 0.2 ANG. 1 ISO A ROUGHNESS ACC. ISO 1302 in M N/A DESCRIPTION A 9954139 N/A 9954139 Copyright (c) by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. orientation in the shop DRAWING:
SHEET:
4 8 5 1 5 2 6 3 7 Copyright (c) by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. 6 7 A.01 10.01 OF 1 N/A
APPROVED YYYY-MM-DD YYYY-MM-DD YYYY-MM-DD DSGN:
DRW:
CHCK:
ARTICLE NUMBER REV. N/A SHEET:
DRAWING:
A.01 10.01 OF 1 N/A 8 F E D C B A 2 2 Weight of antenna: 4 kg 2m / 6ft 1m / 3ft t f 3
m 1 t f 3
m 1 t f 6
m 2 t f 6
m 2 1 2 2m / 6ft 1m / 3ft required label free zone recommended label free zone Power inserter sales floor stock room all antennas in the same direction. GROENLO - HOLLAND description:
quick reference !D Top Copyright by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be repro-
duced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. drw: CB 2013/05/29 chk:
doc. article no: 5279615 rev. : B.01 sheet: 45.01 of 1 drawing: T5279-615 drilling holes (poster recommended)
(not included) ceiling 520mm / 1.7ft 520 1 3 m m / 0 . 5 6 m m 5
. 3
m m 0 9 4x plugs S6 (recommended) 4x screw 4x40 (recommended)
!D Top ceiling installation ceiling steel-cable adjust height press here. 7
. 8
0 2 2 m m 0 2 2 01 02 ceiling not included steel-cable top-view included processing unit power supply Out Power for Reader network IN USB host network OUT USB service port In Power supply 9561811. One needed for every installed system. (not included) Not compatible with IEEE 802.3a* standard Recommended to place in switch-room 1 2 3 4 5 6 7 8 9 10 11 12 H G F 1 Green 2 Blue Blue 3 Red E 1 2 3
buzzer Processing unit at output No device at output Blink Continuous Power inserter at output Power error
!D Reader previous next 1 Yellow Heartbeat 2 Green Disk access 3 Green Firmware running H G F E D C Green RFID active Green Power
fix cable with tie-wrap 01 installation of one !D Top mounting power cable note:
use only cat5e ethernet cable or better, with all 8 wires connected. Led Blue Orange Red Firmware running Error power-supply OUT ceiling unit - network IN 02 installation of one !D Top ceiling RJ45 connector to ethernet outlet - customer network. fix cable with tie-wrap mounting ethernet cable note:
use only cat5e ethernet cable or better, with all 8 wires connected. 01 installation of two !D Tops note:
use only cat5e ethernet cable or better, with all 8 wires connected. RJ45 connector to ethernet outlet - customer network. ceiling fix cable with tie-wrap fix cable with tie-wrap
!D-Top - 1
!D-Top - 2 unit - network OUT unit - network IN place cover 2 1 2 1 2 1 connect voltage supply 230V 110V Note :
The start up of all the processes takes approximately 3 minutes. Model: !D Top Region 2 FCC ID: CGDSTOREIDT IC: 1444A-STOREIDT Model: !D Top Region 2 FCC ID: CGDSTOREIDT IC: 1444A-STOREIDT This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Cet appareil se conforme aux normes RSS 210 exempts de license du Industry Canada. Lopration est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interfrence, et
(2) cet appareil doit accepter nimporte quelle interfrence, y inclus interfrence qui peut causer une opration non pas voulu de cet appareil. Les changements ou modifications nayant pas t expressment approuvs par la partie responsable de la conformit peuvent faire perdre lutilisateur lautorisation de faire fonctionner le matriel. FCC and IC Radiation Exposure Statement:
This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 22 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme a RSS-102 limites nonces pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 22 cm entre le radiateur et votre corps. This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numrique de Classe B est conforme la norme Canadienne ICES-003 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.