FCC ID: 2AQURZW34 Introduction:
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination. ZW34 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The Device Type of the ZW34 is on/off power switch. The Role Type of the ZW34 is Always On Slave Role Type Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Support firmware upgrades via Over-the-air (need Gateways support) Product Overview:
A. Dimmer Button B. Relay Button C. LED Indicator D. OutLine ZW34 Installation Wiring Diagram A B C D Key function description Function 1: press 1x: Dimmer Button turn output ON (to last set brightness level) or OFF Function 2: hold dimmer button: dimmer up or dimmer down Function 3: quickly press 3x UPPER PADDLE FOR DIMMER: inclusion; quickly press 3x LOWER PADDLE FOR DIMMER: exclusion
(relay button does NOT work for inclusion/exclusion) Function 4: quickly press 6x UPPER PADDLE FOR DIMMER: change LED Indicator Parameter 1 Function 5: quickly press 6x relay button: change LED Indicator Parameter 2 Function 6: Whatever state the DIMMER is in, quickly press UPPER paddle 2 times, switch turns on to 100% brightness
(or according to setting in Parameter 17 Function 7: Press and hold for 15 seconds LOWER PADDLE OF DIMMER until all LEDs start blinking quickly, then release and within 5 press and hold the UPPER PADDLE OF DIMMER for 15 SECONDS until all LEDs blink again for 3 seconds to reset factory
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.) Function 8: press and release relay button: relay ON or OFF Function 9: Tap 4x and hold more than 10 seconds LOWER PADDLE OF DIMMER to rotate values in parameter 19 for disabling local control Function10: Tap 4x and hold more than 10 seconds RELAY button to rotate values in parameter 20 Function11: Tap 1x/2x/3x/4x/5x/6x/hold button Activate the scene. Z-Wave Remote Control ADD the ZW34 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
---When prompted by your primary controller, quickly press 3x UPPER PADDLE FOR DIMMER Remove the ZW34 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
---When prompted by your primary controller, quickly press 3x LOWER PADDLE FOR DIMMER Include ZW34 to/from a Z-Wave Gateway with supporting Security.The ZW34 can support the Primary Controller that implemented the security S2. Notice: Including a node ID allocated by Z-WaveTM Controller means Add or Inclusion. Excluding a node ID allocated by Z-WaveTM Controller means Remove or Exclusion. Z-Wave MULTI_CHANNEL ZW34 is multi channel deviceIt has two endpoints. Dimmer is Endpoint1, Relay is Endpoint2. ZW34 Endpoint1 / Endpoint2 Device Type Generic Device Class: GENERIC_TYPE_SWITCH_BINARY Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY Z-Wave protocol Command Class Node Info COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_TRANSPORT_SERVICE_V2, COMMAND_CLASS_VERSION, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_MULTI_CHANNEL_V4, COMMAND_CLASS_SECURITY_2, COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 The Below listed Command Class are all supported the Security S2 COMMAND_CLASS_VERSION, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_MULTI_CHANNEL_V4, COMMAND_CLASS_MULTI_CHANNEL_V4, COMMAND_CLASS_CONFIGURATION ZW34 protocol Endpoint 1 Full Command Class Node Info COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_SECURITY_2 The Below listed Command Class are all supported the Security S2 COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_SWITCH_BINARY ZW34 protocol Endpoint 2 Full Command Class Node Info COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_SECURITY_2 The Below listed Command Class are all supported the Security S2 COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2, COMMAND_CLASS_SWITCH_BINARY Z-Wave Configuration Parameters You may use the below configuration parameters to change settings of the corresponding functionality. 1LED Indicator Mode for Dimmer Paramter No: 1(0x01) Size:1 Byte Value: 00 On when Off and Off when On(Default) Value: 01 On when On and Off when Off Value: 02 Always Off Value: 03 Always On 2: LED Indicator Mode for Relay Paramter No: 2(0x02) Size:1 Byte Value: 00 On when Off and Off when On(Default) Value: 01 On when On and Off when Off Value: 02 Always Off Value: 03 Always On 3: LED Indicator Color for Dimmer Paramter No: 3(0x03) Size:1 Byte Value: 00 White(default) Value: 01 Blue Value: 02 Green Value: 02 Red 4: LED Indicator Color for Dimmer Paramter No: 4(0x04) Size:1 Byte Value: 00 White(default) Value: 01 Blue Value: 02 Green Value: 02 Red 5: LED Indicator Brightness for Dimmer Paramter No: 5(0x05) Size:1 Byte Value: 00 Bright (100%) Value: 01 Medium (60%)(default) Value: 02 Low (30%) 6: LED Indicator Brightness for Relay Paramter No: 6(0x06) Size:1 Byte Value: 00 Bright (100%) Value: 01 Medium (60%)(default) Value: 02 Low (30%) 7: LED Indicator Mode for Scene Paramter No: 7(0x07)Size=1Value: 0 Enable Paramter No: 7(0x07)Size=1Value: 0 Enable Values: 1 Disable( default) 8: Auto Turn-Off Timer for Dimmer Paramter No: 8(0x08)Size=4Value: 0 timer disabled ( default ) Values: 1 65535 (minutes) 9: Auto Turn-On Timer for Dimmer Paramter No: 9(0x09)Size=4Value: 0 timer disabled ( default ) Values: 1 65535 (minutes) 10: Auto Turn-Off Timer for Relay Paramter No: 10(0x0A)Size=4Value: 0 timer disabled ( default ) Values: 1 65535 (minutes) 11: Auto Turn-On Timer for Relay Paramter No: 11(0x0B)Size=4Value: 0 timer disabled ( default ) Values: 1 65535 (minutes) 12: Restores state after power failure Paramter No: 12(0x0C) Size:1 Byte Value: 00 dimmer, relay off Value: 01 dimmer off, relay on Value: 02 dimmer on, relay off Value: 03 previous state for dimmer, previous state for relay( default ) Value: 04 previous state for dimmer, relay on Value: 05 previous state for dimmer, relay off Value: 06 dimmer on, previous state for relay Value: 07 dimmer off, previous state for relay Value: 08 dimmer on, relay on 13: Ramp rate (local button only, remote control by command class) Paramter No: 13(0x0D) Size:1 Byte Value: 00 instant on/off Value: 01 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s(default)
\\\\\\
Value: 99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s 14: Multilevel minimum value can be set Paramter No: 14(0x0E) Size:1 Byte Value: 00--99 (default 01) 15: Multilevel maximum value can be set Paramter No: 15(0x0F) Size:1 Byte Value: 00--99 (default 99) 16: Association reports for dimmer only Paramter No: 16(0x10) Size:1 Byte (default 00) Paramter No: 16(0x10) Size:1 Byte (default 00) Value: 00 Manual control(long press & relay enable): Basic report(without each level, just final level) Manual control(long press & relay disable): Multilevel report (each level will be reported) Value: 01 Manual control(long press & relay enable OR disable): Basic report (without each level, just final level) 17: when switch is on or off and quickly press UPPER paddle 2 times, switch turns on to x brightness Paramter No: 17(0x11) Size:1 Byte Value: 00 turn on to 99(default) Value: 01 turn on to the value relate with parameter 15 18: Double Tap Behavior Paramter No: 18(0x12) Size:1 Byte (default 00) Value: 00 enable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 Value: 01 disable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 Value: 02 disable double tap to full brightness, single tap always to full brightness 19: Enable or Disable local / Z-Wave control for DIMMER Paramter No: 19(0x13) Size:1 Byte (default 01) Value: 00 disable local on/off control Value: 01 enable local and Z-Wave control (normal operation like now) Value: 02 disable local and Z-Wave on/off control 20: Enable or Disable local / Z-Wave control for RELAY Paramter No: 20(0x14) Size:1 Byte (default 01) Value: 00 disable local on/off control Value: 01 enable local and Z-Wave control (normal operation like now) Value: 02 disable local and Z-Wave on/off control 21: Dimmer Speed Setting (only for local press & hold) Paramter No: 21(0x15) Size:1 Byte (default 04) Value: 00--99(Seconds) from 0x63 to 0x00 or from 0x00 to 0x63 need value seconds 22: Ramp rate for Z-Wave on/off controlled Paramter No: 22(0x16) Size:1 Byte (default 00) Value: 00 on/off ramp rate for Z-Wave same as manual control (set in Parameter 13) Value: 01 on/off ramp rate for Z-Wave control set through command class (like now) 23:Default brightness level - in this parameter define default brightness level Paramter No: 23(0x17) Size:1 Byte (default 00) Value: 00 last brightness level Value: 01-99 custom brightness level Support for Association Groups Support for Association Groups ZW34 supports 3 association groups. Group 1 support 1 node ID,Group 23 Support maximum of 5 node IDs Association group_1:Z-Wave Plus Lifeline Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW34 Status change report, 1. ZW34 will trigger AUTO report function if the Switch status had been changed. Association group_2:basic set command When the output of the ZW34 EP1 state is changed, On (0xFF) or Off (0x00). The ZW34 will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group. Association group_3:basic set command When the output of the ZW34 EP2 state is changed, On (0xFF) or Off (0x00). The ZW34 will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group. Restoring Factory Defaults ZW34 is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Remark : All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.