MP26Z 235 x 285 mm 2+6 78.4x40.7mm 80G Specicaon Input: 125VAC 60Hz Frequency: 908.42 MHz Loading: 15A 1875W RESISTIVE OR GENERAL PURPOSE 10A MAX 1250W TUNGSTEN 1/2 HP Temperature Range: 32 F~104 F 3. If the reset fails, exclude the device from your Z-Wave hub (z-wave exclusion). 4.If the z-wave controller does not nd the device, bring the device as close as possible to your z-wave controller and re-add the device. Aer the network conguraon is completed, the device can be moved to the locaon you want. 5. Special reminder for users that connected the device with SmartThings or Hubitat:
(1) For SmartThings: If your z-wave controller is SmartThings, be sure to install the edge driver by following steps to solve the problem of abnormal usage. Z-Wave Mini Smart Plug (800S) MP26Z
(ZW37MU) LED indicator LED Blinks quickly: Add/Inclusion LED Blinks slowly: Remove/Exclusion Program buon Press Once: Manually ON/OFF the device (The buons on the le and right control the outlets on the le and right respecvely.) Press 3 mes quickly (Le/Right): Inclusion/
exclusion mode Press the buon twice quickly then hold a 3rd press for 10 seconds: Return device to factory sengs LED indicator Features:
1. Z-Wave control on/o. 2. Z-Wave controlled AC outlet for standard incandescent lighng, CFL/LEDs, fans or small appliances(1875W Resisve Max). 3. Grounded 3-wire power connecon for safety. 4. Remembers and restores on/o status aer power failure. 5. Built-in Z-Wave Plus signal repeater to extend network range. 6. S2 security and 800 Z-Wave chip for reliable wireless communicaon. 7. Work with most of Z-Wave controllers. Z-WAVE INTEROPERABILITY This product can be included and operated in any Z-Wave network with other Z-Wave-cered devices from other manufacturers and/or other applicaons. All non-baery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (associaon group 1) supporng 1 node for lifeline communicaon. Group 1 must be assigned the Node ID of the primary controller where unsolicited nocaons will be sent. The Z-Wave controller should set this associaon automacally aer inclusion. Lifeline Associaon only supports the Device Reset Locally funcon. Add the Device to Z-Wave Network with QR Code 1. Plug In the Smart Plug: Insert the Z-Wave smart plug into a power outlet. Note: (1) Plug directly into the outlet. Do not use with power strip.
(SmartThings driver subscripon channel)
(guide video) Scan the above QR code(le)to open the SmartThings Edge Driver subscripon channel of the product. Log in to the SmartThings account aer opening the SmartThings Edge Driver subscripon channel. Select the SmartThings Hub you are using, and click "Enroll". Aer "Enroll" is completed, click "Available Drivers". Aer entering the "Available Drivers" page, select "Z-Wave Switch to "Install". Aer installing our egde driver, please remove the device from your hub and re-add it. Note: Please scan the QR code on the right to view the guide video.
(2) For Hubitat: Device handler is needed for this device. Please download it from www.minos-
ton.com. Add Z-Wave Long Range with QR Code The device is compable with SmartStart. SmartStart enabled products can be added to a Z-Wave network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No further acon is required and the SmartStart product will be added automacally within 10 minutes of being switched on and in the network vicinity. Note: Z-Wave Long Range device can only support be included via SmartStart. Extract the DSK from the end device and paste it into the DSK Value in the PC Controller, make sure the "Long Range" opon is cked. Return Factory Defaults Manually reset: Press the buon twice quickly then hold a 3rd press for 10 seconds. Host reset: Aer being removed from the host, the device is restored to factory sengs. Remove the Device 1. Follow the instrucons for your Z-Wave-cered controller to remove a device from the Z-Wave network. 2. Once the controller is ready to remove your device, press the manual buon on the le/right smart plug 3 mes quickly. Associaon Group The device supports 3 groups and each group supports up to 5 devices. Group 1 Lifeline Group 2 Le outlet sends basic set Group 3 right outlet sends basic set
(2) The device may need to be within 100 feet of the z-wave controller to pair. Therefore, it is recommended to move the device within 100 feet of the controller, and then relocate it to the desired location in your home once paired. If the device is included in this way, be sure to refresh the network. 100 feet Please contact us if you have any quesons:
www.minoston.com ask@minoston.com Parameter Sengs 2. Refer to your specic Z-Wave hub or controller's instrucons to enter inclusion mode. 3. Put the device in Inclusion Mode: Scan the QR on the device and then press the buon
(le/right) 3 mes quickly. Scan here for SmartStart inclusion Note: FULL DSK Code can be found on the packaging box. Do not remove or damage them. 4. Wait for Pairing Conrmaon: The Z-Wave controller should detect the smart plug, and you may receive a conrmaon on the controller. Conrm it to complete the sengs. Troubleshoong:
1. If the device does not enter pairing mode (the LED indicator does not blink), press the device buon 3 mes faster. 2. If the device does not enter pairing mode (the LED indicator does not blink) even aer pressing the device buon 3 mes faster, reset the device by pressing the buon twice quickly then hold a 3rd press for 10 seconds. LED Indicator Status This parameter can set the status of the indicator light when the device is turned on or o. Operaon: Press the manual buon 6 mes quickly to change parameters. Parameter =1, size =1byte, value=00(default) Led on when outlet on Parameter =1, size =1byte, value=01 Led o when outlet on Parameter =1, size =1byte, value=02 LED always ON Parameter =1, size =1byte, value=03 LED always OFF 2.Timer Auto-o This parameter can set a mer to turn o the device automacally. The value entered in the parameter corresponds to the number of minutes. Operaon: Set up in the z-wave hub. Parameter =2, Size=4byte, Values:0-65535 (Min) Parameter =3, Size=4byte, Values:0-65535 (Min) Value=0(default) auto-o the le outlet auto-o the right outlet disable 3.Timer Auto-on This parameter can set a mer to turn on the device automacally. The value entered in the parameter corresponds to the number of minutes. Operaon: Set up in the z-wave hub. Parameter =4, Size=4byte, Values: 0 65535 (Min) Parameter =5, Size=4byte, Values:0 65535 (Min) auto-on the le outlet auto-on the right outlet 4.Power-on Status This parameter can set the power condion of the socket aer the device is powered on. Operaon: Press the manual buon 10 mes quickly to change the parameter. Parameter=6Size=1byte Value=0 Output is always o Value=1 Output is always o Value=2 Output memory last status(default) 5.Adjust LED Brightness This parameter can set the brightness of the device LED indicator. Operaon: Press the manual buon 8 mes quickly to change the parameter. Parameter=7, Size=1byte Value=0 Bright Value=1 Medium Value=2 Low (default) GRNERIC DEVICE CLASS:
0x10 - SWITCH BINARY SPECIFIC DEVICE CLASS:
0x00 NOT_USED COMMAND CLASSES:
COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SWITCH_BINARY_V2 COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_INDICATOR COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 COMMAND_CLASS_CONFIGURATION_V4 FCC / IC This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operaon is subjected to the following two condions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operaon. FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by modicaons to this equipment. Such modicaons could void the users authority to operate the equipment. IC Cauon.
- English:
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two condions: (1) This device may not cause interfer-
ence, and (2) This device must accept any interference, including interference that may cause undesired operaon of the device.
- French:
Le prsentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitaonestautorise aux deux condions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareildoit accepter tout brouillageradiolectriquesubi, mmesi le brouillageest suscepble d'encompromere le fonconnement. FCC Cauon. This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operaon. Any Changes or modicaons not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separaon between the equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio / TV technician for help. RF warning for Portable device:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. To comply with the FCC RF exposure compliance requirements, no change to Important note:
the antenna or the device is permied. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void users authority to operate the device. CAUTION - PLEASE READ!
This device is intended for installaon in accordance with the Naonal Electric Code and local regulaons in the United States, or the Canadian Electrical Code and local regulaons in Canada If you are unsure or uncomfortable about performing this installaon consult a qualied electrician. WARNING RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING-TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING-TYPE POWER OUTLET. IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY. CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT DO NOT EXCEED RATINGS DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP ETC.) MEDICAL EQUIPMENT Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be used to control the On / O status of Medical and / or Life Support equipment. CONTROLLING APPLIANCES Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. The reason is that the appliance you want to control may be in a separate room and if unintenon-
al behavior occurs (such as a device turning on or o - either intenonally via schedules or unintenonally via network error) this event may lead to a hazardous condion. For these reasons, please note the following suggesons:
1) Do not include Z-Wave devices in Groups or Scenes if they control appliances. 2) Do not use Z-Wave devices to control electric heaters or any other appliances that may present a hazardous condion due to unaended, unintenonal, or automac power control.