all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user manual | Users Manual | 70.68 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
Internal picture | Internal Photos | 183.17 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
External picture | External Photos | 163.06 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
Label-rev1 | ID Label/Location Info | 97.04 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
ACB-Form-FCC agent | Cover Letter(s) | 15.66 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
ACB-Form-FCC-Confidentiality | Cover Letter(s) | 23.03 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
report FCC IC-rev1 | Test Report | 1006.71 KiB | August 08 2019 / September 08 2019 | |||
1 |
|
test Setup | Test Setup Photos | 128.57 KiB | August 08 2019 / September 08 2019 |
1 | user manual | Users Manual | 70.68 KiB | August 08 2019 / September 08 2019 |
Model : BNR-U144Y instructions Technical parameters:
Battery parameters: 12V23A Transmission frequency: 433.92MHz Remote control by remote control handle:
Press the button on the remote control handle, the indicator light will be on, the corresponding remote control signal will be emitted, and the control receiver will conduct corresponding operation. Battery replacement:
The remote control handle is powered by 12V23A battery. When the remote control distance gets closer or when the button is pressed, there is no indicator light, please replace the battery of the product, the battery model is 12V23A. Open the battery cover plate on the back of the remote control handle by pressing down and then pushing in the direction indicated by PUSH. remove the old battery, according to the instructions of the battery polarity, the prepared new battery according to the battery polarity into. Push the battery cover into the product to complete the battery replacement. Caution:
This device complies with Part 15 of the FCC Rules / Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference. (2) this device must accept any interference received, including interference that may cause undesired operation. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
1 | Internal picture | Internal Photos | 183.17 KiB | August 08 2019 / September 08 2019 |
FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Internal Picture Page 1 of 2 FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Antenna Page 2 of 2
1 | External picture | External Photos | 163.06 KiB | August 08 2019 / September 08 2019 |
FCC ID: 2ATL2T12V007H IC: 25145-T12V007H External Picture Page 1 of 3 FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Page 2 of 3 FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Page 3 of 3
1 | ACB-Form-FCC agent | Cover Letter(s) | 15.66 KiB | August 08 2019 / September 08 2019 |
NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD Authority to Act as Agent Date: July 3, 2019 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern:
Intertek Testing Service Shanghai is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: Dec 31, 2020 San panl sun jianli
(Signature') (Print name) Title: Sas ety (ey-Gification Cagineet On behalf of: __ NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD
(Company Name) Telephone: sskpourey +& | IB] bust) By:
1. Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
1 | ACB-Form-FCC-Confidentiality | Cover Letter(s) | 23.03 KiB | August 08 2019 / September 08 2019 |
NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD Request for Confidentiality Date: July 3, 2019 Subject: Confidentiality Request for: _ FCC ID: 2ATL2T12V007H___ Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Lj Short Term J Permanent Block Diagrams C1 Short Term External Photos XO Short Term ZC Permanent *! Internal Photos U3 Short Term ] Permanent Operation Description/Theory of Operation O Short Term LC Permanent Parts List & Placement/BOM 0 Short Term CO Permanent Tune-Up Procedure Lj Short Term J Permanent Schematics Lj Short Term Test Setup Photos UD Short Term ZC Permanent *? Users Manual NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to
"competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality:
The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of __ (specify number of days not to exceed 180)__ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications:
IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: Sun \tan ly | Sa (erbhication Gonincee sun jianli
(Signature/Title*) (Print name) 1. The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at:
https://apps.fec.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 . Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3. Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
1 | report FCC IC-rev1 | Test Report | 1006.71 KiB | August 08 2019 / September 08 2019 |
NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD RF TEST REPORT Report Type:
FCC Part 15.231 & ISED RSS-210 RF report Model:
BNR-U144Y REPORT NUMBER:
190600666SHA-001 ISSUE DATE:
Jul 31, 2019 DOCUMENT CONTROL NUMBER:
TTRF15.231_V1 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com Report no.: 190600666SHA-001 NINGBO BAINIAN ELECTRIC APPLIANCE CO., LTD NO, 785, XINCHENG NORTH ROAD, HUSHAN TOWN, CIXI CITY, ZHEJIANG PROVINCE, CHINA NINGBO BAINIAN ELECTRIC APPLIANCE CO., LTD NO, 785, XINCHENG NORTH ROAD, HUSHAN TOWN, CIXI CITY, ZHEJIANG PROVINCE, CHINA NINGBO BAINIAN ELECTRIC APPLIANCE CO., LTD NO, 785, XINCHENG NORTH ROAD, HUSHAN TOWN, CIXI CITY, ZHEJIANG PROVINCE, CHINA 2ATL2T12V007H 25145-T12V007H TEST REPORT Applicant:
Manufacturer:
Manufacturing site:
FCC ID:
IC:
SUMMARY:
The equipment complies with the requirements according to the following standard(s) or Specification:
47CFR Part 15 (2018): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-210 Issue 9 (August 2016): Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment RSS-Gen Issue 5 (April 2018): General Requirements for Compliance of Radio Apparatus PREPARED BY:
Project Engineer Teddy Yin REVIEWED BY:
Reviewer Daniel Zhao This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.231_V1 2018 Intertek Page 2 of 29 TEST REPORT Report No.: 190600666SHA-001 Content REVISION HISTORY................................................................................................................................................ 4 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 5 1 GENERAL INFORMATION ............................................................................................................................. 6 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 6 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 7 2 TEST SPECIFICATIONS ................................................................................................................................... 8 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 8 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 8 2.3 TEST SOFTWARE LIST ............................................................................................................................................ 8 2.4 TEST PERIPHERALS LIST ......................................................................................................................................... 8 2.5 TEST ENVIRONMENT CONDITION: ............................................................................................................................ 9 2.6 INSTRUMENT LIST .............................................................................................................................................. 10 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 11 3 FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ...................................... 12 3.1 LIMIT .............................................................................................................................................................. 12 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 13 3.3 TEST CONFIGURATION ........................................................................................................................................ 14 3.4 TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 16 4 POWER LINE CONDUCTED EMISSION ......................................................................................................... 22 4.1 LIMIT .............................................................................................................................................................. 22 4.2 TEST CONFIGURATION ........................................................................................................................................ 22 4.3 MEASUREMENT PROCEDURE ............................................................................................................................... 23 4.4 TEST RESULTS OF POWER LINE CONDUCTED EMISSION............................................................................................... 24 5 EMISSION BANDWIDTH ............................................................................................................................. 25 5.1 LIMIT .............................................................................................................................................................. 25 5.2 MEASUREMENT PROCEDURE ............................................................................................................................... 25 5.3 TEST CONFIGURATION ........................................................................................................................................ 25 5.4 THE RESULTS..................................................................................................................................................... 26 6 DEACTIVATING TIME .................................................................................................................................. 27 6.1 TEST LIMIT ....................................................................................................................................................... 27 6.2 TEST CONFIGURATION ........................................................................................................................................ 27 6.3 TEST PROCEDURE AND TEST SETUP ........................................................................................................................ 28 6.4 TEST PROTOCOL ................................................................................................................................................ 28 ANTENNA REQUIREMENT .......................................................................................................................... 29 7 TTRF15.231_V1 2018 Intertek Page 3 of 29 TEST REPORT Revision History Report No. Version Description 190600666SHA-001 Rev. 01 Initial issue of report Report No.: 190600666SHA-001 Issued Date Jul 31, 2019 TTRF15.231_V1 2018 Intertek Page 4 of 29 Report No.: 190600666SHA-001 Measurement result summary TEST REPORT TEST ITEM FCC REFERANCE IC REFERANCE RESULT Fundamental & spurious emission
&Restrict band radiated emission 15.231(b) 15.209(a) 15.205 RSS-210 A.1.2 RSS-Gen Issue 5 Clause 8.9&8.10 Power line conducted emission 15.207 Emission bandwidth 15.231(c) Deactivating time 15.231(a)(1) RSS-Gen Issue 5 Clause 8.8 RSS-210 Issue 9 A1.3 RSS-GEN Issue 5 6.7 RSS-210 Issue 9 A1.1(a) Pass NA Pass Pass Antenna requirement 15.203
-
Pass Notes: 1: NA =Not Applicable 2: Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement uncertainty. 3: Additions, Deviations and Exclusions from Standards: None. TTRF15.231_V1 2018 Intertek Page 5 of 29 TEST REPORT 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Report No.: 190600666SHA-001 Product name:
Type/Model:
Description of EUT:
Rating:
Category of EUT:
EUT type:
Software Version:
Hardware Version:
Transmitter BNR-U144Y The EUT is a transmitter to control the working condition of the corresponding receiver. DC 12V Class B Table top Floor standing
/
/
Sample received date:
Jun 1, 2019 Date of test:
Jun 1~23, 2019 1.2 Technical Specification Operation Frequency:
433.92MHz Type of Modulation:
FSK Mobile Portable Fix Location Product Type:
Channel Number:
1 Antenna Designation:
Integral PCB antenna, non-user removable Gain of Antenna:
0dBi (Declared by manufacture) TTRF15.231_V1 2018 Intertek Page 6 of 29 TEST REPORT 1.3 Description of Test Facility Report No.: 190600666SHA-001 Name:
Intertek Testing Services Shanghai Address:
Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone:
86 21 61278200 Telefax:
86 21 54262353 The test facility is recognized, certified, or accredited by these organizations:
CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab CAB identifier.: CN0051 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 TTRF15.231_V1 2018 Intertek Page 7 of 29 TEST REPORT Report No.: 190600666SHA-001 2 TEST SPECIFICATIONS 2.1 Standards or specification 47CFR Part 15 (2018) ANSI C63.10 (2013) RSS-210 Issue 9 (August 2016) RSS-Gen Issue 5 (April 2018) 2.2 Mode of operation during the test Within this test report, EUT was tested with modulation and tested under its rating voltage and frequency. The EUT is a handheld device, so three axes (X, Y, Z) were observed while the test receiver worked as max hold continuously and the highest reading among the whole test procedure was recorded. Compare with the test results that X axis is the worst case. 2.3 Test software list Test Items Software Manufacturer Version Conducted emission ESxS-K1 Radiated emission ES-K1 R&S R&S V2.1.0 V1.71 2.4 Test peripherals list Item No. Name Band and Model Description 1
/
/
/
TTRF15.231_V1 2018 Intertek Page 8 of 29 TEST REPORT 2.5 Test environment condition:
Report No.: 190600666SHA-001 Test items Temperature Humidity Fundamental & spurious emission
& Restrict band radiated emission Power line conducted emission Emission bandwidth & Deactivating time 25C
/
25C 53% RH
/
53% RH TTRF15.231_V1 2018 Intertek Page 9 of 29 TEST REPORT 2.6 Instrument list Radiated Emission Used Equipment Test Receiver Bilog Antenna Pre-amplifier Horn antenna Semi-anechoic chamber RF test Used Equipment PXA Signal Analyzer Additional instrument Used Equipment Therom-
Hygrograph Therom-
Hygrograph Report No.: 190600666SHA-001 Manufacturer R&S TESEQ R&S R&S Type ESIB 26 CBL 6112D AFS42-00101800-
25-S-42 HF 906 Albatross
-
Internal no. EC 3045 EC 4206 EC5262 EC 3049 EC 3048 Due date 2019-09-12 2019-12-10 2020-06-11 2019-11-16 2019-07-31 Manufacturer Type Internal no. Due date Keysight N9030A EC 5338 2020-03-04 Manufacturer Type Internal no. Due date S.M.I.F. EC 5198 2020-02-27 S.M.I.F. EC 3325 2020-04-07 ZJ1-2A ZJ1-2A TTRF15.231_V1 2018 Intertek Page 10 of 29 TEST REPORT Report No.: 190600666SHA-001 2.7 Measurement uncertainty The measurement uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Test item Measurement uncertainty Maximum peak output power Radiated Emissions in restricted frequency bands below 1GHz Radiated Emissions in restricted frequency bands above 1GHz Emission outside the frequency band Power line conducted emission 0.74dB 4.90dB 5.02dB 2.89dB 3.19dB TTRF15.231_V1 2018 Intertek Page 11 of 29 TEST REPORT Report No.: 190600666SHA-001 3 Fundamental & Spurious Emission & Restrict band radiated emission Test result:
Pass 3.1 Limit 3.1.1 The emission shall test through the 10th harmonic or to 40GHz, whichever is lower. It must comply with the limits below:
Fundamental Frequency Fundamental limit Spurious limit
(MHz) (uV/m) (uV/m) ___________________________________________________________ 40.66 40.70 2250 225 70 130 1250 125 130 - 174 1250 to 3750 174 - 260 3750 260 470 3750 to 12500 375 to 1250 Above 470 12500 1250 375 125 to 375 ___________________________________________________________ The formulas for calculating the maximum permitted fundamental field strengths are as follows: for the band 130-174 MHz, uV/m at 3 meters = 56.81818(Frequency) - 6136.3636; for the band 260-470 MHz, uV/m at 3 meters = 41.6667(Frequency) - 7083.3333. The maximum permitted unwanted emission level is 20 dB below the maximum permitted fundamental level. For that the EUT use fundamental frequency of 433.92MHz, after calculation, the limit is:
Fundamental limit = 41.6667 * 433.92 - 7083.3333 = 10996.68 uV/m = 80.80dBuV/m Spurious limit = 81 20 = 60.80dBuV/m
/////////////////////////////////////////////////////////////////////////////////////////////////
3.1.2 The radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) showed as below:
Frequency Field Strength Measurement Distance
(MHz) (dBuV/m) (m) ___________________________________________________________ 30 - 88 40.0 3 88 - 216 43.5 3 216 - 960 46.0 3 Above 960 54.0 3 ______________________________________________________ TTRF15.231_V1 2018 Intertek Page 12 of 29 TEST REPORT Report No.: 190600666SHA-001 3.2 Measurement Procedure For Radiated emission below 30MHz:
a) The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber room. The table was rotated 360 degrees to determine the position of the highest radiation. b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c) Both X and Y axes of the antenna are set to make the measurement. d) For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. e) The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. NOTE:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency below 30MHz. For Radiated emission above 30MHz:
a) The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above 1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to determine the position of the highest radiation. b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c) The height of antenna is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d) For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. e) The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum hold mode when the test frequency is below 1 GHz. f) The test-receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets average limit, measurement with the average detector is unnecessary. Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at frequency below 1GHz. 2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz for Peak detection (PK) at frequency above 1GHz. 3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 1/T (Duty cycle < 98%) or 3 x RBW (Duty cycle 98%) for Average detection (AV) at frequency above 1GHz. 4. All modes of operation were investigated and the worst-case emissions are reported TTRF15.231_V1 2018 Intertek Page 13 of 29 TEST REPORT 3.3 Test Configuration For Radiated emission below 30MHz:
Report No.: 190600666SHA-001 EUT&
Support Units 3m Turn Table 80cm Test Receiver For Radiated emission 30MHz to 1GHz:
EUT&
Support Units 3m Turn Table 80cm Ant. Tower 1-4m Variable Test Receiver TTRF15.231_V1 2018 Intertek Page 14 of 29 TEST REPORT For Radiated emission above 1GHz:
Report No.: 190600666SHA-001 EUT&
Support Units 3m Ant. Tower 1-4m Variable Turn Table Absorber 150cm Test Receiver TTRF15.231_V1 2018 Intertek Page 15 of 29 Report No.: 190600666SHA-001 TEST REPORT 3.4 Test Results of Radiated Emissions The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit line per 15.31(o) was not reported. All keys were pre-tested, and the onkey is the worst case. Level [dBV/m]
Horizontal 90 80 70 60 50 40 30 20 10 x x x x x x 0 30M 50M 70M 100M Frequency [Hz]
x MES 0502999H10_red MES 0502999H10_pre LIM FCC 15 F 3 QP Field Strength QP Level [dBV/m]
80 70 60 50 40 30 20 10 0 1G 2G Frequency [Hz]
MES 0502999H15_pre LIM FCC 15 F 3 PK Field Strength QP LIM FCC 15 F 3 AV Field Strength QP 200M 300M 500M 700M 1G 3G 4G 5G 6G TTRF15.231_V1 2018 Intertek Page 16 of 29 Report No.: 190600666SHA-001 TEST REPORT Level [dBV/m]
80 70 60 50 40 30 20 x 10 Vertical x x x x x 0 30M 50M 70M 100M Frequency [Hz]
x MES 0502999V10_red MES 0502999V10_pre LIM FCC 15 F 3 QP Field Strength QP Level [dBV/m]
200M 300M 500M 700M 1G 80 70 60 50 40 30 20 10 0 1G 2G Frequency [Hz]
3G 4G 5G 6G MES 0502999V15_pre LIM FCC 15 F 3 PK Field Strength QP LIM FCC 15 F 3 AV Field Strength QP TTRF15.231_V1 2018 Intertek Page 17 of 29 TEST REPORT Test data:
Report No.: 190600666SHA-001 Polarization Frequency
(MHz) Corrected Reading
(dBV/m) Correct Factor
(dB/m) Emission Type Limits Margin
(dBV/m)
(dB) Detector H V 433.92 867.81 2172.34 30.00 433.92 867.81 2172.34 83.8 31.2 45.9 20.2 72.9 29.8 34.6 18.3 23.2
-6.3 18.6 18.3 23.2
-6.3 Fundamental Spurious Spurious Spurious Fundamental Spurious Spurious 100.8 80.8 80.8 80.8 100.8 80.8 80.8 17.0 49.6 34.9 60.6 27.9 51.0 46.2 PK PK PK PK PK PK PK Remark: 1. Correct Factor = Antenna Factor + Cable Loss (+ Amplifier, for higher than 1GHz), the value was added to Original Receiver Reading by the software automatically. 2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided. Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB, Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10.00dBuV, Limit = 40.00dBuV/m. Then Correct Factor = 30.20 + 2.00 32.00 = 0.20dB/m;
Corrected Reading = 10dBuV + 0.20dB/m = 10.20dBuV/m;
Margin = 40.00dBuV/m - 10.20dBuV/m = 29.80dB. TTRF15.231_V1 2018 Intertek Page 18 of 29 TEST REPORT Duty Cycle:
The test data with maximum duty cycle was listed below. The worst Duty cycle= (0.92*13+0.30*20) / 44.50 = 0.40 All keys were pre-tested, and the onkey is the worst case. TTRF15.231_V1 2018 Intertek Page 19 of 29 Report No.: 190600666SHA-001 TEST REPORT Report No.: 190600666SHA-001 TTRF15.231_V1 2018 Intertek Page 20 of 29 Report No.: 190600666SHA-001 TEST REPORT Calculating the AV value according to the duty cycle Antenna H H H V V V Frequency
(MHz) 433.92 867.81 2172.34 433.92 867.81 2172.34 PK Reading
(dBuV/m) Correct Factor
(dB) AV Reading
(dBuV/m) 83.8 31.2 45.9 72.9 29.8 34.6
-8.0 75.8 23.2 37.9 64.9 21.8 26.6 Limit Margin
(dBuV/m) 80.8 60.8 60.8 80.8 60.8 60.8
(dB) 5.0 37.6 22.9 15.9 39.0 34.2 Remark:
1. Correct Factor = 20lg (duty cycle) = 20lg (0.40) = -8.0;
2. AV Reading = PK Reading + Correct Factor;
3. Margin = limit - AV Reading. TTRF15.231_V1 2018 Intertek Page 21 of 29 Report No.: 190600666SHA-001 TEST REPORT 4 Power line conducted emission Test result:
NA 4.1 Limit Frequency of Emission (MHz) Conducted Limit (dBuV) 0.15-0.5 0.5-5 5-30 QP 66 to 56*
56 60 AV 56 to 46 *
46 50
* Decreases with the logarithm of the frequency. 4.2 Test Configuration EUT Peripheral devices LISN LISN EMI receiver TTRF15.231_V1 2018 Intertek Page 22 of 29 TEST REPORT Report No.: 190600666SHA-001 4.3 Measurement Procedure Measured levels of ac power-line conducted emission shall be the emission voltages from the voltage probe, where permitted, or across the 50 LISN port (to which the EUT is connected), where permitted, terminated into a 50 measuring instrument. All emission voltage and current measurements shall be made on each current-carrying conductor at the plug end of the EUT power cord by the use of mating plugs and receptacles on the LISN, if used. Equipment shall be tested with power cords that are normally supplied or recommended by the manufacturer and that have electrical and shielding characteristics that are the same as those cords normally supplied or recommended by the manufacturer. For those measurements using a LISN, the 50 measuring port is terminated by a measuring instrument having 50 input impedance. All other ports are terminated in 50 loads. Tabletop devices shall be placed on a platform of nominal size 1 m by 1.5 m, raised 80 cm above the reference ground plane. The vertical conducting plane or wall of an RF-shielded (screened) room shall be located 40 cm to the rear of the EUT. Floor-standing devices shall be placed either directly on the reference ground-plane or on insulating material as described in ANSI C63.4. All other surfaces of tabletop or floor-standing EUTs shall be at least 80 cm from any other grounded conducting surface, including the case or cases of one or more LISNs. The bandwidth of the test receiver is set at 9 kHz. TTRF15.231_V1 2018 Intertek Page 23 of 29 TEST REPORT 4.4 Test Results of Power line conducted emission Report No.: 190600666SHA-001 Remark: 1. Correct Factor = LISN Factor + Cable Loss, the value was added to Original Receiver Reading by the software automatically. 2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided. TTRF15.231_V1 2018 Intertek Page 24 of 29 TEST REPORT 5 Emission Bandwidth Test result:
Pass Report No.: 190600666SHA-001 5.1 Limit The bandwidth of the emission shall be no wider than 0.25 % of the center frequency for devices operating above 70MHz and below 900MHz. For devices operating above 900 MHz, the 99% bandwidth shall be less or equal to 0.5% of the center frequency. The limit for the EUT = 0.25% * 433.92 MHz = 1085 kHz 5.2 Measurement Procedure The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal metal ground plane. The turn table rotated 360 degrees to determine the position of the maximum emission level. The EUT was set 3 meters away from the receiving antenna which was mounted on an antenna mast. The antenna moved up and down between from 1meter to 4 meters to find out the maximum emission level. The central frequency of test receiver was set near the operating frequency of EUT. The test was conducted using the Spectrum Analyzer with the resolutions bandwidth set at 1kHz, the video bandwidth set at 3kHz. 5.3 Test Configuration Ant. Tower 1-4m Variable EUT&
Support Units 3m Turn Table 80cm Test Receiver TTRF15.231_V1 2018 Intertek Page 25 of 29 Report No.: 190600666SHA-001 TEST REPORT 5.4 The results All keys were pre-tested, and the onkey is the worst case. Frequency
(MHz) 433.92 Limit Result 20dB Bandwidth
(kHz) 9.116 1085 Complied 99%
Bandwidth
(kHz) 64.772 1085 Complied TTRF15.231_V1 2018 Intertek Page 26 of 29 Report No.: 190600666SHA-001 TEST REPORT 6 Deactivating time Test result:
Pass 6.1 Test limit
(1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmissions, including data, to determine system integrity of transmitters used in security or safety applications are allowed if the total duration of transmissions does not exceed more than two seconds per hour for each transmitter. There is no limit on the number of individual transmissions, provided the total transmission time does not exceed two seconds per hour.
(4) Intentional radiators which are employed for radio control purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operate during the pendency of the alarm condition.
(5) Transmission of set-up information for security systems may exceed the transmission duration limits in (1) and (2) above, provided such transmission are under the control of a professional installer and do not exceed ten seconds after a manually operated switch is released or a transmitter is activated automatically. Such set-up information may include data. 6.2 Test Configuration EUT&
Support Units 3m Turn Table 80cm Ant. Tower 1-4m Variable Test Receiver TTRF15.231_V1 2018 Intertek Page 27 of 29 Report No.: 190600666SHA-001 TEST REPORT 6.3 Test procedure and test setup The measurement was applied in a semi-anechoic chamber. The central frequency of test receiver was set as the operating frequency of EUT and the Span was set as 0. The EUT was switched once. The test receiver recorded the whole time from the triggered moment to the time of stopping radiating. For manual switching, to avoid uncertainty, the operating above would be repeated five times and the worst data is recorded. 6.4 Test protocol Whole time from the triggered moment to the time of stopping radiating: 440ms. As a result, the EUT complies with the limit of 5s deactivating time. All keys were pre-tested, and the onkey is the worst case. TTRF15.231_V1 2018 Intertek Page 28 of 29 TEST REPORT Report No.: 190600666SHA-001 7 Antenna requirement Requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. Result:
EUT uses permanently PCB antenna to the intentional radiator, so it can comply with the provisions of this section.
******************************************* END ************************************
TTRF15.231_V1 2018 Intertek Page 29 of 29
1 | test Setup | Test Setup Photos | 128.57 KiB | August 08 2019 / September 08 2019 |
FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Test Setup Page 1 of 2 1. Radiated Emission Above 1GHz FCC ID: 2ATL2T12V007H IC: 25145-T12V007H Below 1GHz Page 2 of 2
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-09 | 433.92 ~ 433.92 | DSC - Part 15 Security/Remote Control Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-08-09
|
||||
1 | Applicant's complete, legal business name |
NINGBO BAINIAN ELECTRIC APPLIANCE CO.,LTD
|
||||
1 | FCC Registration Number (FRN) |
0028552834
|
||||
1 | Physical Address |
NO, 785, XINCHENG NORTH ROAD, HUSHAN TOWN CIXI CITY, ZHEJIANG PROVINCE, CHINA
|
||||
1 |
NO, 785, XINCHENG NORTH ROAD, HUSHAN TOWN
|
|||||
1 |
cixi
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ATL2
|
||||
1 | Equipment Product Code |
T12V007H
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
s******** j****
|
||||
1 | Telephone Number |
0574-********
|
||||
1 | Fax Number |
0574-********
|
||||
1 |
s******@chinatimer.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
T****** Y****
|
||||
1 | Physical Address |
Building No.86
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
86-21********
|
||||
1 |
t******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
T******** Y********
|
||||
1 | Physical Address |
Building No.86
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
86-21********
|
||||
1 |
t******@intertek.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSC - Part 15 Security/Remote Control Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Transmitter | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
L**** X******
|
||||
1 | Telephone Number |
+86 2********
|
||||
1 |
l******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231 | 433.92000000 | 433.92000000 |