RAV Technical support Technical specification aUraalucolamearieaecad (ea) DD1187 sensor uses button battery for power supply, with 3 modes and 4 light levels for choice,it can also test light intensity with low voltage alarm function. e Input voltage: 3V(CR2032) e Transmitting frequency: 433.925MHz+100KHz e Transmitting power: 10 milliwatt
* Operating temperature: -20C C BY AN INCORRECT TYPE. Intensity Level: 15klux~7sklux DISPOSE OF USED BATTERIES ACCORDING. Transmitting distance: 200 meters open office, See oe Notice: transmitter do not exposed to moisture and strike, so as not to affect life. 35 meters on two walls When you use transmitter, if found emission distance obviously short or less sensitive, please change another same new battery. Please have batteries for recycling. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED The default is o level. Short press SUN button to show current light level. Short press SUN button to turn to different light levels. Intensity Level Technical support Light grade The abve grades equal to 1:When the grade is o,the light will close 2:When the grade is the light reaches over 15KLUX,the awning will fold, LED flashing
> grade 30KLUX 3:When the grade is 2,the light reaches over 30KLUX,the awning will fold,LED flashing 3 grade | 4sKLUX 4:When the grade is 3,the light reaches over 45KLUX,the awning will fold, LED flashing 4 grade 60KLUX 5:When the grade is 3,the light reaches over 60KLUX,the awning will fold, LED flashing During the settings, the time between A Matchable R/E/ED tubular motor set up A two operation must be shorter than 4s, otherwise it will quit the setting Additional function s Tubular motor Setting is ok a emitters setting Setting switch on button(P2) x2 button(P2) x1 During the settings, the time between Matchable DC43 set up b two operation must be shorter than 4s, otherwise it will quit the setting Additional function Sp sys fs Co > > => OK
(coal Setting is ok Dc43 switch on Setting Indicator Stop button x1 Indicator Up buttonX1 Indicator flashing button(P2) x 1 flashing long flashing and extinguished During the settings, the time between b two operation must be shorter than 4s, Matchable D@136 set up Additional otherwise it will quit the setting function
= 3) a i & D> omy > | >@.> > y >is OX a. 5 Setti i Cy etting is o Dai36 switch on Setting Indicator Stop buttonx1 Indicator Up button x1 Indicator flashing button(P2) 1 flashing long flashing and extinguished
: m After testing, if it shows level o, it means the light level Ambient light test f) is below level 1; you can press any button to quit testing. Additional If no operations within 2 min, it will quit automatically. function
(P2+Sun) X35 Level o continuous light, entering test Show current light level Press any button to quit yan Sensor work mode
(The sucking disk of sensor f) After issuing orders,the sensor will re eat this kind of command 10s later Additional Should be toward to the sun) P function mode 4 Sensors in weak light will not launch up the command Set light intensity | When light intensity is beyond ee h u h : When light intensity is below the setting enge orsrade) he eer ihore Shall 2 GUESS), (more than 15 minutes),the sensor is in the sensor will issue command of
~ d cai Pee i a state of weak light, and will not OiMAWIOrS OF ora LOS TOnee launch an ascending order. blinds will be downward mode 2 The shutter operation will not block at sun sensor
-e- . -e-
OY oe :
. ye y ) EP Set light intensity | When light intensity is beyond When light intensity is below the setting a~ (not "ograde) the setting (more than 2 minutes), (more than 15 minutes),the sensor will the sensor will issue command of issue command of upward-otion,and the downward-otion,and the roller roller blinds will be upward blinds will be downward d The shutter down will Please ensure the roller blinds is above the sensor.If it covers mode 3 block the sun sensor at the sensor during the downward-motion,it will change the direction to upward;until the sensor catch the light,it won't stop.
\ Ry oe 2 Set light intensity | When light intensity is beyond When light intensity is below the setting aa (not "ograde) the setting (more than 2 minutes), (more than 15 minutes),the sensor will the sensor will issue command of issue command of upward-otion,and the downward-otion,and the roller roller blinds will be upward blinds will be downward View and switch sensor mode Additional function . <> 10S >
y y Press Sun button momentarily, Light no flashing mode 1 Long press Sun After indicating light flashes and release it.The indicating Light flashes 2 time mode 2 button,hold on 5 times,you can switch light of sun-intensity falshes Light flashes 3 time mode 3 mode 1,mode 2,mode 3 Please replace battery promptly after low-voltage hint low voltage hint function Additional function . N =
o ~ 7]
Set light intensity (not "ograde) No operation(below 2.6V) flashes 10 times every 2 minutes FCC Warning:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designedto provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interferenceto radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,the user is encouragedto try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning:
This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio RSS-210. Lexploitation est autorise aux deux conditions suivantes :
(1) appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre lexemption des limites courantes dvaluation dans la section 2.5 de RSS 102 et la conformit a lexposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur lexposition et la conformit de rf. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 5 mm between the radiator and your body. Cet metteur ne doit pas tre Co-plac ou ne fonctionnant en mme temps quaucune autre antenne ou metteur. Cet equipement devrait tre install et actionn avec une distance minimum de 5mm entre le radiateur et votre corps.