Tubular Motor-
DM45CEQ/S Specification A-OO Product introduction Functional features Integrated radio control Setting up + add emitter +delete emitter Motor direction setting option Resistance stop function Jogging&tilt function Set electronic limit Set /delete the third limit position Low standby power 85
-10 Operating temperature Technical Dare Type Rated Torque(N.m) Rated speed(RPM) Rated Voltage(V) Emission frequency(MHz) DM45CEQ/S 3N.m 28RPM 12V 433.925MHz Motor Installation Driving tube must be close-fitting with crown and drive adapter. Choose crown and drive adapter based on the driving tube. Drive tube Drive tube Runner Circlip Crown Tail insert bracket Stroke support Rechargeable Description The motor can be charged by both the power adapter or the 12V supply electricity.Is that is rechargeable by solar panel or adaptor when the battery is low. 1 2 V b a t t e r y p o l e Operation note Please read the fallowngprecautions befor use 1. Dont operate motors wheuin low wltage alarm Motor stop running When the supply voltage is lower than 7 v and it will restart again when the voltage is greater than 7.5V If the voltage is less than 10v, the motor will alarm for 10 times to prompt it needs to be charged every timewhen the motor is working. 2. Optrating:
The valid interval of the emitter button is 10s,the emitter will quit the set after 10s The motor will run or beep for hint,please do the next step after the hint. 3. Set limit position After the up limit and down limit setting,and the up limit down limit and third limit position are at the same location After limit settingwith power and memory function;
Into the match-code status 2 minutes later, it will quit out the setting limits status automatically It will delete every memory and restore the factory settings 4. When the motor running without any operation, the maximum running time is 6 minutes,it will stop automatically 5 If the emitterlost,please set up again with new emitter READING Button specification Setting button(P1) Adapter or battery rod Channel-
(P1-) FACTORY MODE 1 Setting up Display Up Stop Down Setting P2 Channel+
(P1+) If you need to reverse the rotateon of the motor controlled by the emitter,please run the reverse of direction setting(as lists in the second point of the P1 button setting) Run for hint x1 Di x1 Run for hint x2 Di x3 Set up is ok Press 2s loosen P1 Press 2s 2 The reverse of direction setting The blind run down
+
Run for hint x1 Successful change the direction Press 1s Press 2s 3 Limit position 1, Enter the limit setting mode Or Dot-move Or Continuous moving Press 1s Press 2s 2, Set up limit
(UpUp+Stop) The blind run up The up limit point Press 1s Confirm the Blind to stop in the up limit position 3, Set down limit DownStop+Down The blind run down The down limit point Press 1s Confirm the Blind to stop in the down limit position Run for hint x2 Di x3 Set up is ok Run for hint x2 Di x3 Set up is ok
+
Press 2s
+
Press 2s Note: After setting up the up and down limit into user mode. USER MODE 1 Fine-tune up/down limit position Enter the limit setting mode Run for hint x1 Di x1 Enter fine-tune up limit mode Or
+
Press 5s Run for hint x1 Di x1 Enter fine-tune down limit mode
+
Press 5s Note: Can not be fine-tune up/down limit position at the same time. Or Dot-move Or Continuous moving Press 1s Press 2s Adjust the new up limit point Run for hint x2 Di x3 Or
+
Confirm the new up limit point P2 M P2 Lithium Cell 3V Press 1s Press 2s Adjust the new down limit point Run for hint x2 Di x3 4 Add Emitter Method one Run for hint x1 Di x1 Run for hint x2 Di x3 Emitter adding is ok Press 2s loosen P1 Press 2s Method two P2 P2 P2 Run for hint x1 Di x1 Run for hint x1 Di x1 Run for hint x2 Di x3 P2 P2 P2 Emitter adding is ok I O P E R A T O N G U D E I
+
Confirm the new down limit point Press 1s Press 1s Press 1s Press 1s Press 2s 2 The third limit position setting 1, The third limit position setting
(P2StopStop) Note:Emitter is the one already matched code, while emitter has not 5 Delete one emitter P2 P2 P2 Run for hint x1 Di x1 Run for hint x1 Di x1 Run for hint x2 Di x3 P2 P2 P2 One emitter is deleted After the up limit and down limit setting, you can set the third limit point between them as the half open position;
Press 1s Press 1s Press 1s Already set up, down limit position Any position The blind stops The third limit position
(any position) Press 1s Run for hint x1 Di x1 Run for hint x1 Di x1 Run for hint x2 Di x3 P2 Set up is ok Press 1s Press 1s Press 1s Long press the stop button for 2s,the roller blinds will move to the third limit 2, The third limit cancel
(P2StopStop) Run for hint x1 Di x1 Run for hint x1 Di x1 P2 Run for hint x1 Di x1 Set up is ok Press 1s Press 1s Press 1s 3 Dot-move/Continuous moving function switch switch Run for hint x1 Run for hint x1 Di x1
+
Dot-move function Press 5s Press 1s Run for hint x1 Run for hint x2 Di x3
+
Continuous moving function Press 5s Press 1s Notes: Repetitive operation dot-move and continuous moving function switching cycle, under the dot-move function, according to the upor down button more than 2S release motor linkage operation. Note:With the same method,you only can delete the emitter not the emitter P1 BUTTON OPERATION Functions that can be operated under any mode 1, Activate motor for the first time Run for hint x1 Di~~x1 Activate is ok Long Press P1 loosen P1 2, The reverse of direction setting Run for hint x2 Dix2 Successful change the direction Long Press P1 loosen P1 3, Restore factory settings Run for hint x3 Dix3 Set up is ok Long Press P1 loosen P1 FAULT AND SOLUTION NUMBER PHENOMENON REASON PROCESSING METHOD 1 2 The motor alarms when it is working The voltage is low in the alarm mode Charge the battery Motor cant running a,The battery is not activated. b,Theemitter is not matched. c,If press P1 button for a aActivate the motor after fully charged bSet up the match code cContact the engineers for after-sales. FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.