INSTR,INSTL,GD00Z-4 - P/N: 236956 AX4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000 X 8.500 - TOL. +/-.125" - SCALE: 1-1 - FOLDING: 2-FOLD ALTERNATE - SIDE 1 OF 2 PRINTERS INSTRUCTIONS:
GD00Z-4 APPLIANCE CONTROLS GARAGE DOOR OPENER REMOTE COMMAND TRANSCEIVER with TILT SENSOR Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340 www.nortekcontrol.com PRODUCT COMPONENTS POWER INPUT JACK CONNECTION WIRES OPTIONAL ADJUSTABLE GD00Z-4 MOUNTING BRACKET GD00Z-4 STATUS INDICATOR WIRE TIES SCREW AND MOUNTING HARDWARE FOR ADJUSTABLE BRACKET TILT SENSOR SCREWS AND MOUNTING TAPE FOR TILT SENSOR POWER SUPPLY WARNING LIGHT LINK BUTTON MOUNTING SCREWS AND ANCHORS FOR GD00Z-4 POWER SUPPLY RETAINING BRACKET SCREW FOR POWER SUPPLY BRACKET PRODUCT DESCRIPTION GD00Z-4 Overview
A garage door opener remote command transceiver with built-in Z-Wave technology.
Allows remote operation of a garage door opener using Z-Wave controllers.
Acts as a Z-Wave repeater to improve communications within the Z-Wave mesh network. GD00Z-4 Summary of Operation
GD00Z-4 connects to the garage door openers pushbutton wall console terminals.
A wireless tilt sensor mounts on the garage door and reports the doors position to the GD00Z-4.
GD00Z-4 responds to Z-Wave commands from Z-Wave controllers to open or close the garage door.
A warning indicator light ashes and
a beeper sounds for 5 seconds before the door begins to move. If the door does not completely open or close, a second open or close command can be sent after 30 seconds. If the door does not completely open or close after the second attempt, the GD00Z-4 operation is suspended until a local garage door pushbutton is activated. Z-Wave Information
Z-Wave is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.
Z-Wave is an Interoperable two-way RF mesh networking technology designed for use with a Z-Wave gateway/
controller and other Z-Wave enabled devices.
Replication is the process of copying or transferring your Z-Wave network from one controller to another.
This is a Security enabled Z-Wave product and must be used with a Security enabled Z-Wave controller in order to fully utilize this product. As such, this device will not respond to Basic CC commands.
ASSOCIATION: The GD00Z-4 supports 1 Group with 1 Node. Group 1 must be assigned the Node ID of the controller to which unsolicited noti cations from the GD00Z-4 will be sent. The Z-Wave controller should set this association automatically after inclusion. TILT SENSOR INSTALLATION AND BATTERY 1 To activate the tilt sensor, remove the battery protection pull strip 2 Attach the mounting plate to the top panel of the door 3 Snap the sensor onto the mounting plate ARROWS ON PLATE
& SENSOR POINT UP
"UP"
ARROWS POST ON BOTTOM Use double sided tape or the two mounting screws supplied
(drill 1/16" pilot holes if required) The system will notify you when the battery is low, replace the battery with a type CR2032 coin cell LOW BATTERY REPLACEMENT 2 PLUS SIDE UP !!!
CR2032 Insert the battery into the transmitter 1 To open the case, twist a small screwdriver in case slot SLOT SAFETY NOTES WARNING This operator system is equipped with an unattended operation feature. This door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR!
WARNING This system can be installed on sectional type (roll up) doors only per (UL-325). DO NOT INSTALL ON ONE-PIECE DOORS!
WARNING The Remote Command Transceiver must be mounted in the garage, in sight of the garage door, where the visual and audible movement warning indicators can be clearly seen and heard. WARNING Do not install the Remote Command Transceiver on garage door operators manufactured prior to 1993
(models without an operational safety beam entrapment detection system). PAIRING (INCLUDING) WITH THE SYSTEM Note: Plug in the GD00Z-4 near your Z-Wave Controller for these steps WALL OUTLET POWER SUPPLY GD00Z-4 POWER INPUT JACK LINK BUTTON TO INCLUDE THE GD00Z-4 INTO YOUR CONTROLLER TO EXCLUDE THE GD00Z-4 FROM YOUR CONTROLLER Place your Z-Wave Controller into Discovery or Include mode. 1 Place your Z-Wave Controller into Exclude mode. Press and release the link button on the GD00Z-4. 2 Press and release the link button on the GD00Z-4. Confirm that the GD00Z-4 was recognized by your Z-Wave Controller. 3 Confirm that the GD00Z-4 was excluded by your Z-Wave Controller. 1 2 3 Refer to your Z-Wave Controllers instructions for additional information on including devices. Refer to your Z-Wave Controllers instructions for additional information on excluding devices. INSTR,INSTL,GD00Z-4 - P/N: 236956 AX4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000 X 8.500 - TOL. +/-.125" - SCALE: 1-1 - FOLDING: 2-FOLD ALTERNATE - SIDE 2 OF 2 PRINTERS INSTRUCTIONS:
GD00Z-4 MOUNTING Tilt sensor mounted on the top panel of the door The GD00Z-4 typically mounts on the ceiling near the opener and the power outlet GD00Z-4 CONNECTIONS 2 Plug the power cord into the power input jack on the GD00Z-4 1 Use the four screws and anchors to mount the GD00Z-4 above the opener 3/16" HOLES FOR ANCHORS
! WARNING !
REMOVE POWER FROM THE GARAGE DOOR OPENER BEFORE CONTINUING THE GD00Z-4 WARNING LAMP MUST BE VISIBLE IN ALL DOOR POSITIONS THE GD00Z-4 CAN ALSO BE ATTACHED TO THE OPENER'S HARDWARE USING THE ADJUSTABLE MOUNTING BRACKET Secure bracket with screw INDENT 1A The optional adjustable mounting bracket fits 3 ways on the GD00Z-4 The bracket snaps onto indents on either side or on the end of the GD00Z-4 INDENT 1 Connect the GD00Z-4 connection wires to the pushbutton wall console terminals on the garage door opener. The terminals may be named "PWC", "WC",
"PB", "PUSHBUTTON", or "RED and WHITE". Terminal names and locations vary by model. Either wire can connect to either terminal INDENT 2A GARAGE DOOR OPENER Use the bolts and nuts supplied to attach the bracket to a secure structure BE SURE THE GD00Z-4 IS CLEAR OF ALL MOVING PARTS OF THE GARAGE DOOR AND THE WARNING LAMP IS NOT OBSTRUCTED PUSHBUTTON PUSHBUTTON 3 Remove the screw from 120 VAC outlet faceplate. Secure the retaining bracket to the faceplate with the provided screw. Snap the power supply into the bracket while plugging into the outlet. DO NOT DISCONNECT ANY WIRES CURRENTLY CONNECTED TO THE GARAGE DOOR OPENER !!!
USE WIRE TIES TO SECURE EXCESS WIRING CLEAR OF ALL MOVING PARTS OF THE GARAGE DOOR AND OPENER OPERATION NOTES 1. The warning light will ash and the warning beeper will sound for ve seconds before the door opener is activated. STAY CLEAR OF THE DOOR, AND DOOR OPENER. THEY ARE ABOUT TO MOVE!
If the door does not completely open or close after remote activation, the GD00Z-4 will allow user to try to operate the door one more time. If the second attempt fails, the GD00Z-4 will go into lock-out mode. See Note #3. If the GD00Z-4 is in lock-out mode and will not accept remote commands, activate the door from the pushbutton wall console. 2. 3. 4. Once the GD00Z-4 has initiated the movement of the garage door, another command cannot be sent for 30 seconds. This eliminates the chance of bouncing the garage door and possibly damaging the garage door opener. Strobe: 360 Lumens Audible Alarm: 45 db @ 10 feet Mounting: Screws and anchors to Communications: Z-Wave (908.4 MHz) GD00Z-4 Speci cations Power Supply: Input: 120 VAC, 0.8 A Output: 12 VDC, 2 A Operating Temperature: -4122 F (-2050 C) Tilt Sensor Speci cations Power Supply: Type CR2032 Coin Cell Battery Operating Temperature: -4122 F (-2050 C) Mounting to Garage Door: Double-sided tape or two Communications: Proprietary 345 MHz Battery Life: 24 Months (typical) the ceiling, or bracket to the openers hanging hardware Range: 100 feet line-of-sight to GD00Z-4 mounting screws
(Speci cations subject to change without notice) NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY INFORMATION: THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS PERCHLORATE MATERIAL - SPECIAL HANDLING MAY APPLY - SEE www.dtsc.ca.gov/hazardouswaste/perchlorate KEEP AWAY FROM SMALL CHILDREN. IF BATTERY IS SWALLOWED, PROMPTLY SEE A DOCTOR. DO NOT TRY TO RECHARGE THIS BATTERY. DISPOSAL OF USED BATTERIES MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA. TROUBLESHOOTING PROBLEM Unable to include in Z-Wave network. The GD00Z-4 does not ash or beep when activated. POSSIBLE CAUSE GD00Z-4 was not properly excluded from a previous Z-Wave network. No power to the GD00Z-4. The GD00Z-4 ashes and beeps when activated but the door does not move. Obstruction blocking the door or incorrect wiring. CORRECTIVE ACTION 1. Reset the GD00Z-4 by pressing the LINK button 5 times. A quick beep followed by a longer beep will indicate the reset. 1. Make sure the power supply is plugged in securely to a live outlet. 2. Make sure the power cord is plugged in securely to the GD00Z-4. 1. Make sure that there are no obstacles preventing the door from moving. 2. Make sure that the GD00Z-4 connection wires are connected to the proper terminals on the garage door opener. Trace the wires from the garage door openers pushbutton wall console to the door opener. This is where the GD00Z-4 connection wires should be connected. Garage door opens or closes, but the status does not change on the Z-Wave Controller. The tilt sensor signal is not being received by the GD00Z-4. 1. Make sure the tilt sensor is mounted correctly on the garage door, with the arrow pointing up. 2. Make sure the battery pull tab has been removed from the tilt sensor. 3. Replace the battery in the tilt sensor. SYSTEM OPERATION 1 2 3 4 5 Restore power to your garage door opener To synchronize the system, use the garage door opener's pushbutton to manually open and close the door Use your Z-Wave Controller to activate your garage door opener STAY CLEAR OF THE DOOR !!!
BEEP BEEP BEEP The GD00Z-4 will beep and flash for five seconds before the door moves FLASH FLASH FLASH The GD00Z-4 will activate the door opener and open or close the door STAY CLEAR OF THE DOOR !!!
NORTEK SECURITY & CONTROL LIMITED WARRANTY This Nortek Security & Control product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through Nortek Security & Controls normal distribution channels. Nortek Security & Control does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealers warranty, if any. There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or pro t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for tness, are valid only until the warranty expires. This Nortek Security & Control LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Nortek Security & Control Returns at 1-855-546-3351 for an RPA# and other important details. REGULATORY NOTICES Changes or modi cations not expressly approved by the manufacturer could void the users authority to operate the equipment. Les changements ou modi cations non approuvs expressment par la partie responsable de la conformit pourrait annuler lautorit de lutilisateur faire fonctionner lquipement. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures. Increase the separation between the equipment and receiver
Reorient or relocate the receiving antenna
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Copyright 2015 Nortek Security & Control LLC 236956 AX4