Quick Install Guide
EL-SC-300
System Controller
IMPORTANT SAFETY INSTRUCTIONS
1.
Read, understand and follow ALL safety and installation instructions included in this
manual. Failure to follow the included documentation may damage the product and will void
manufacturer’s warranty.
Follow ALL installation guidelines included with the product. Installation of the product in high
humidity environments, in close proximity to heat sources and /or non-recommended locations
will impede, interfere and/or damage the intended operation of the product.
2.
3. Only use attachments and accessories which have been specified for use by the manufacturer.
4.
The use of abrasive, liquid or solvent based cleaning fluids will damage the product. Please refer
and follow all Product Care instructions included with the product.
Product Servicing may only be completed by authorized or certified service centers & personnel.
For a complete list of product servicing options, please follow instructions included in the
product documentation and /or contact original manufacturer for details.
5.
FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and
RSS-247.
RESTRICTIONS IN THE 5 GHZ BAND: Within the 5.15 to 5.25 GHz band, UNII devices will be restricted to
indoor operations.
Operation is subject to the following two conditions:
1.
2.
This device may not cause interference and
This device must accept any interference, including interference that may cause undesired
operation of the device.
Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-247.
RESTRICTIONS DANS LA BANDE DE 5 GHZ: Dans la bande de 5,15 à 5,25 GHz, les appareils UNII seront
restreints aux opérations.
Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer
d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent
affecter son fonctionnement.
Warning:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and
meets the exemption from the routine evaluation limits in section 2.5 of RSS 102.
1.
2.
This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters from user and bystanders.
Warning:
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102, and users
can obtain Canadian information on RF exposure and compliance from the Canadian Representative Nortek
Control at Tel: 604-765-6933.
To maintain compliance, only the antenna types that have been tested shall be used.
This radio transmitter [IC: 1078A-00211] has been approved by Innovation, Science and Economic
Development Canada to operate with the antenna types listed below, with the maximum permissible gain
indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated
for any type listed are strictly prohibited for use with this device.
2
QUICK INSTALL GUIDELe présent émetteur radio [IC: 1078A-00211] a ét approuvpar Innovation, Sciences et Développement
économique Canada pour fonctionner avec les types d’antenne énumérés cidessous et ayant un gain
admissible maximal. Les types d’antenne non inclus dans cette liste, et dont le gain est supérieur au gain
maximal indiqu?pour tout type figurant sur la liste, sont trictement interdits pour l’exploitation de l’émetteur.
Antenna Manufacturer: JIADE WIRELESS TECHNOLOGY (SHEN ZHEN) Co., LTD
Model number: JD-B3DB-SMA; Gain (dBi): 3; VSWR: 1.92.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
La puissance de sortie émise par l’appareil de sans fil est inférieure à la limite ‘exposition aux fréquences
radio d’Industry Canada (IC). Utilisez l’appareil de sans fil de façon à minimiser les contacts humains
lors du fonctionnement normal. Ce périphérique a également été évalué et démontré conforme aux
limites d’exposition aux RF d’IC dans des conditions d’exposition à des appareils mobiles (antennes sont
supérieures à 20 cm à partir du corps d’une personne).
FCC and IC Registrations
FCC ID: EF400211
IC: 1078A-00211
Z-Wave Operating Frequency
Australia/New Zealand: 919.8, 921.4 MHz
US/Canada: 908.40, 908.42, 916 MHz
European: 868.40, 868.42, 869.85 MHz
Z-Wave Developer’s Kit: 7.13.1
This product can be operated in any Z-Wave™ network with other Z-Wave certified devices from other
manufacturers. All mains operated nodes within the network will act as repeaters of vendor to increase
reliability of the network.
In an Elan SC Series System Controller, the host application controls the device reset feature.
If this controller is the primary controller for your network, resetting it will result in the nodes in your
network being orphaned and it will be necessary after the reset to exclude or re-include all of the
nodes in the network. If this controller is being used as a secondary controller in the network, use this
procedure to reset the controller only in the event that the network primary controller is missing or
otherwise inoperable.
3
EL-SC-300Contents
1. Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4. RS-232 Serial Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5. RS-485 Serial Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6. IR Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7. Signal Input Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8. Relay Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
9. LAN / PoE Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10. Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
11. Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
12. LED Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13. Network Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
14. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4
QUICK INSTALL GUIDEThe ELAN Training Guide contains valuable hardware and software reference documentation and is
considered an important supplement to this document. Make sure you have the latest version by visiting
the ELAN Dealer website at www.elancontrolsystems.com and follow the Dealer Resources link.
• (10) Phoenix style male connectors, (4) black for signal inputs, (6) green for relays
Status Indicator LED
Power
Included in the box:
• (1) EL-SC-300 System Controller
• (2) Rack Mount Brackets
• (1) 12V DC Power Supply
• (7) Male DB9 to female RJ45 adapter
• (3) Female DB9 to female RJ45 adapter
• (1) Wi-Fi Antenna
1. Front Panel
EL-SC-300 System Controller
2. Rear Panel Connections
Serial Connections
8 bi-directional RS-232 ports
Null-modem configurable
Signal Inputs
4 signal input ports
Detect contact closure or
voltage input to trigger events
Detects 5 -24VDC / 24VAC Max
Relay Connections
6 relays
12VDC 24VAC @ 1A
WiFi Antenna
2.4GHz / 5GHz
Ethernet Connection
10/100/1000 Mbps
PoE IEEE 802.3at/af 48VDC 600mA
Power
Connector
DC power
input
12V - 2.5A
Serial Connections
2 bi-directional RS-485 ports
IR Outputs
12 discreet IR ports (12V)
Compatible with Xantech
single and dual emitters
Audio Out
Doorbell audio output
USB
3.0 USB
2.0 USB
For external storage
and Z-Wave antenna
HDMI
On-screen
display
Reset
Resets to system
defaults
5
EL-SC-3003. Mounting
The EL-SC-300 System Controller is designed to mount on a shelf or hang in a cabinet or rack.
Shelf Mounting
The EL-SC-300 has feet to protect finished surfaces. Set the controller in a location that will allow you
to properly manage connected wiring so that tension is not placed on the connections. Wire tension will
cause the unit to move and may cause wires to become disconnected.
Dimensions with feet: 17” W x 2.25” H x 14” D (431.8mm W x 57.2mm H x 355.6mm D)
Rack Mounting
The Rack Mount Brackets included with the EL-SC-300 attach to the chassis using the included screws.
Do not use longer screws to attach the brackets as this may permanently damage the unit.
Remove the feet from the EL-SC-300 before rack mounting the unit. When mounting in very warm
locations (i.e. enclosed rack or cabinet) leave a rack space above and/or below the unit for ventilation.
Dimensions without feet, with rack mount brackets: 19” W x 1.75” H x 14” D (482.6mm W x 44.45mm H x
355.6mm D)
4. RS-232 Serial Connections
Connect up to eight RS-232 serial controlled devices using an included DB9 to RJ45 adapter to the RS-232
port on the rear of the controller.
For null modem connections, the ports can be configured in ELAN Configurator.
Wiring pin-out for the RJ45 connector.
RS-232 Port Pin #
586A Color Code
586B Color Code
Function
1
2
3
4
5
6
7
8
White / Green
White / Orange
Green
Orange
White / Orange
White / Green
Blue
Blue
White / Blue
White / Blue
RXD (receive)
Orange
Green
TXD (transmit)
White / Brown
White / Brown
Brown
Brown
N/C
DCD
DTR
GND
CTS
RTS
RS-232 Connections
The table shows the 568A and 568B color codes and the function of each conductor of the RS-232 ports.
Please refer to the ELAN Integration Note for the specific device to determine the proper RJ45 to DB9
adapter to use.
CAUTION: Do not connect cables with PoE power on them to the RS-232 or RS-485 ports as it will
damage the unit.
6
QUICK INSTALL GUIDE5. RS-485 Serial Connections
The two RS-485 ports allow connection to Full Duplex (Aprilaire thermostats, for example) and Half Duplex
(Pentair Pool and Spa controllers, for example) RS-485 controlled devices without using adapters. The
table below shows the T-568A and T-568B color codes and the function of each conductor of the RS-485
ports. Please refer to the Integration Notes for the device you are integrating for wiring and programming
specifics.
CAUTION: Do not connect cables with PoE power on them to the RS-232 or RS-485 ports as it will damage
the unit.
RS-485 Port
Pin #
586A Color Code
586B Color Code
Naming Conventions
1
2
3
4
5
6
7
8
White / Green
White / Orange
RxD +
RD (B)
Green
Orange
RxD -
RD (A)
White / Orange
White / Green
TxD +
TD (B)
Blue
Blue
White / Blue
White / Blue
Orange
Green
TxD -
TD (A)
White / Brown
White / Brown
GND
Brown
Brown
N/C
N/C
GND
N/C
B+
B-
A+
A-
GND
6. IR Output Connections
Twelve discrete IR outputs are supplied to control third party devices. Each output is compatible with
Xantech single and dual emitters. IR outputs are 12V.
7. Signal Input Connections
Four signal input ports provide a way to trigger events based on a contact closure or voltage input. Detects
5V to 24V DC / 24VAC Max. For example, use a contact closure on driveway sensors to trigger lights or
push messages. Or use the voltage detector to sense when a standard doorbell chime is rung to trigger an
ELAN doorbell chime through an audio system.
NOTE: DO NOT WIRE DIRECTLY TO THE DOORBELL BUTTON, THIS WILL DAMAGE THE EL-SC-300.
For detailed wiring instructions, please refer to the Integration Note.
Contact Closure*
Door Chime
DC Input
Doorbell
Button
24V
Chime
+
-
+
-
DC Output
5VDC- 24VDC
7
*Please verify your device can accept 12V input for contact closure, as this could cause damage
the device if not rated for 12V.
EL-SC-3008. Relay Connections
Six normally open relays are available for controlling third party devices - motorized lifts, window shades,
and projection screens. The included removable connectors will accept up to 16ga bare copper leads.
Be careful to verify that no portion of one wire touches the other wire. Prior to connection verify that the
connected load does not exceed 24volts AC/DC or 1amp. If either parameter is exceeded, add a higher
capacity relay to control the load and use the EL-SC-300 output to control that relay.
NOTE: The relays only control turning the external load on / off and do not supply any power.
For detailed wiring instructions, please refer to the Integration Note and documentation for the connected
device.
9. LAN / PoE Connection
The EL-SC-300 can be powered over Ethernet (PoE). The minimum PoE requirement is IEEE 802.3at. 42.5
- 57 VDC, 600 mA maximum.
NOTE: The EL-SC-300 can be connected via WiFi, however a wired connection is preferred.
10. Reset Button
Located on the right rear of the controller is the recessed pinhole button that can be used in three ways:
1.
2.
2 second press and release resets the controller to DHCP
20 second press and release removes all configuration information. Software version will be
maintained.
3. While applying power, a 10 second press and release will perform a full factory reset. Software
will revert to factory default version. DO NOT remove power during a factory reset as it will
permanently damage the unit. Allow the unit to reboot and become discoverable (about 4
minutes). Note: the LED will remain red during the reset process.
Once all other connections have been completed, connect an Ethernet cable connected to a PoE switch or
the 12 VDC, 2.5A power supply to the DC input.
WARNING! THESE ACTIONS CANNOT BE UNDONE!
11. Power
12. LED Status Indicator
The LED communicates the status of the controller:
Blue
Power on / connected to network
Blue flashing slowly
Boot up
Blue flashing rapidly
Controller updating
Amber
Power on / not connected to network
Red
Boot failure
Red flashing
Self check failure
8
QUICK INSTALL GUIDE13. Network Connection
The EL-SC-300 is factory set to use DHCP. First, connect to a wired network. Once connected, use
Configurator to set a static IP address or connect via WiFi.
• USB 2.0: 5VDC / 0.5A and USB 3.0: 5VDC / 1.0A (supplied by external AC / DC adapter)
14. Specifications
Connections
• RS-232, Null modem configurable - (8) RJ-45 ports
• RS-485 - (2) RJ-45 ports
• IR Output, (Mono), - 12V DC - (12) 3.5mm ports
• Signal Input - (4) Terminal Block Connectors 3-pin
• Relay - (6) Terminal Block Connectors 3-pin
• HDMI 1.4b - (1) For on screen display
• USB 2.0: 5VDC / 0.5A or USB 3.0: 5VDC / 1.0A (supplied by PoE)
• RCA Audio - (2) Stereo audio out
• Ethernet / PoE IEEE 802.3af (802.3at Type 1) - (1) RJ-45 port
• Power (1) Coaxial Type A, 2.5mm inside diameter. 12V 2.5A
• 2.4 / 5 GHz WiFi 802.11 b/g/n/ac
System
Software compatibility: Refer to the integration note for compatibility
Updates managed by ELAN Core Module software
General
Operating Temperature: 0° to 40° C
Operating Humidity: 90% Maximum (Non-Condensing)
Mounting: Free standing, Rack mount
Product Dimensions
With feet: 17” W x 2.25” H x 14” D (431.8mm W x 57.2mm H x 355.6mm D)
Without feet, with rack mount brackets: 19” W x 1.75” H x 14” D (482.6mm W x 44.45mm H x 355.6mm D)
Weight 8 lbs, 11oz / 3.95kg
Certifications
CE, FCC, C-Tick / RCM
9
EL-SC-300Notes
10
QUICK INSTALL GUIDENotes
11
EL-SC-300Limited Warranty
Nortek Security & Control ( ‘NSC’ ) warrants the EL-SC-300 to be free from defects in materials and
workmanship for the period of two years (2 years) from the date of purchase. If within the applicable
warranty period above purchaser discovers that such item was not as warranted above and promptly
notifies ‘NSC’ in writing, ‘NSC’ shall repair or replace the item at the company’s option. This warranty
shall not apply (a) to equipment not manufactured by ‘NSC’, (b) to equipment which shall have been
installed by other than an ‘NSC’ authorized installer, (c) to installed equipment which is not installed to
‘NSC’s’ specifications, (d) to equipment which shall have been repaired or altered by others than ‘NSC’,
(e) to equipment which shall have been subjected to negligence, accident, or damage by circumstances
beyond ‘NSC’s’ control, including, but not limited to, lightning, flood, electrical surge, tornado, earthquake,
or other catastrophic events beyond ‘NSC’s’ control, or to improper operation, maintenance or storage, or
to other than normal use of service. With respect to equipment sold by, but not manufactured by ‘NSC’,
the warranty obligations of ‘NSC’ shall in all respects conform to the warranty actually extended to ‘NSC’
by its supplier. The foregoing warranties do not cover reimbursement for labor, transportation, removal,
installation or other expenses which may be incurred in connection with repair or replacement. Except
as may be expressly provided and authorized in writing by ‘NSC’, ‘NSC’ shall not be subject to any other
obligations or liabilities whatsoever with respect to equipment manufactured by ‘NSC’ or services rendered
by ‘NSC’.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND IMPLIED
WARRANTIES EXCEPT WARRANTIES OF TITLE, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
ATTENTION: TO OUR VALUED CUSTOMERS
To ensure that customers obtain quality pre-sale and after-sale support and service, Nortek Security &
Control products are sold exclusively through authorized dealers. Nortek Security & Control products are
not sold online. The warranties on Nortek Security & Control products are NOT VALID if the products have
been purchased from an unauthorized dealer or an online E-tailer. To determine if your Nortek Security &
Control reseller is authorized, please call Nortek Security & Control at (707) 283-5900.
www.nortekcontrol.com
©2021 Nortek Security & Control LLC. All Rights Reserved. ELAN is a registered trademark of Nortek
Security & Control LLC.
12
P/N: 10024525 Rev-C
QUICK INSTALL GUIDE