INSTR,INSTL,GLASS BREAK,ZW - P/N: 235512 X8 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000 X 8.500 - FOLDING: 4-FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1 PRINTERS INSTRUCTIONS:
GB00Z-1 WIRELESS GLASS BREAK DETECTOR Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com 3. INSTALLING OR CHANGING BATTERIES INSERT TWO CR123A BATTERIES INTO BATTERY HOLDERS OBSERVE POLARITY !!!
GREEN INDICATOR WILL FLASH ONCE WHEN BATTERIES ARE INSTALLED 6. DETECTOR TESTING WARNING DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. 1 FROM THE IRIS WEB SITE, CLICK THE DEVICES TAB 2 ON THE GLASS BREAK DETECTOR DEVICE CLICK "MANAGE"
3 CLICK TEST RED GLASS BREAK 2ND STAGE INDICATOR DETECTION MICROPHONE 2. FEATURES 1. PRODUCT DESCRIPTION The Model GB00Z-1 is a battery powered glass break detector with built-in Z-Wave interoperable two-way RF mesh networking technology designed for use with Lowes Iris Smart Home Hub. This device is used for perimeter protection. The GB00Z-1 can send ve different signal types: fault, restore, low battery, status, and tamper. The Iris system hub must be paired with the glass break detector before system testing and operation. Refer to the Lowes Iris system Web site for details on pairing and testing the detector. In a typical installation, the detector is mounted on a wall or ceiling within 15 feet of the protected glass window(s). The unit uses dual-stage digital audio processing to detect the sound of breaking glass in a 360 area around the device. If the unit detects breaking glass, a fault signal is sent to the system followed by a restore signal. Periodically, the unit sends a status signal to update the system. If the battery tests low, a low battery signal is included with any transmission. The glass break detector is powered from two 3-Volt CR123A lithium batteries (included). An internal switch senses if the detector is removed from its base. Removing the detector will send a tamper signal to the system. Three screws and screw anchors are provided for mounting the detector. 4. PAIRING OR UN-PAIRING THE DETECTOR WITH THE HUB 5. MOUNTING THE DETECTOR REMOVABLE MOUNTING ALIGNMENT INDICATORS DETECTOR BASE BASE PARING THE DETECTOR TO ADD TO HUB UN-PARING THE DETECTOR WHEN INSTRUCTED, PRESS THE BUTTON ON THE DETCTOR TO REMOVE FROM HUB GREEN 1ST STAGE INDICATOR MOUNTING SCREWS AND ANCHORS TEST BUTTON 1 LOCATE THE DETECTOR ON THE ADJACENT OR OPPOSITE WALL OR ON THE CEILING WITHIN 15 FEET OF THE WINDOW BEING PROTECTED 2 USE THE MOUNTING BASE AS A TEMPLATE TO MARK THE LOCATION OF THE THREE MOUNTING HOLES NOTE: WHEN WALL MOUNTING, ORIENT THE TEST BUTTON DOWN 3 DRILL 3/16" PILOT HOLES FOR THE SCREW ANCHORS AND PUSH THE ANCHORS INTO THE HOLES AFTER INSTALLING BATTERIES, WAIT 5 SECONDS FOR THE POWER UP DELAY 1 FROM THE IRIS WEB SITE, CLICK THE DEVICES TAB 1 2 3 4 PLACE DETECTOR WITHIN 10 FEET OF THE IRIS SYSTEM HUB FROM THE IRIS WEB SITE, CLICK THE DEVICES TAB, THEN CLICK THE
"ADD DEVICES" BUTTON SELECT GLASS BREAK DETECTOR FROM THE LIST 5 FOLLOW THE ON-SCREEN INSTRUCTIONS TO PAIR THE DETECTOR WITH THE HUB 2 ON THE GLASS BREAK DETECTOR DEVICE CLICK "MANAGE"
3 CLICK REMOVE 4 FOLLOW THE ON-SCREEN INSTRUCTIONS TO UN-PAIR THE DETECTOR WITH THE HUB Operating Frequency: 908.42 MHz Operating Temperature: 32 to 120 F (0 to 49 C) Operating Relative Humidity: 5 to 95%, non-condensing 7. SPECIFICATIONS The minimum size for all glass types is 11 x 11 (28 cm x 28 cm) square. Glass must be framed, in a wall of the room or mounted in a barrier of 36 (91 cm) minimum width. Battery Type: Two 3-Volt CR123A Lithium Batteries Sensor Type: Single microphone, dual-stage (thud & crash) MOUNTING SCREWS NOTE: IF THE BATTERIES ARE NOT INSTALLED, THE DETECTOR WILL NOT ALLOW MOUNTING TO THE BASE 4 ATTACH THE MOUNTING BASE WITH THE THREE SCREWS 5 ATTACH THE DETECTOR TO THE BASE, MATCH THE ALIGNMENT MARKS AND TURN CLOCKWISE 8. LINEAR LIMITED RETAIL WARRANTY Linear LLC (the Company) warrants to the original purchaser that products delivered hereunder will be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. The Company within said period shall at its option, either repair or replace free of charge, any product or part thereof found, upon the Companys inspection, to be so defective, and will return the repaired or replaced product to the purchaser at Companys expense. All products returned for warranty service require a Return Product Authorization Number (RPA#). For warranty service, shipping instructions, and an RPA#, contact Linear Technical Services at 1-800-421-1587. Devices must be sent to the Company at owners expense and be accompanied with statement of defect and proof of purchase. This warranty is conditioned on the following:
1. The Company must be notified within one year of purchase and have been given the opportunity of inspection by return of any alleged defective product free and clear of all liens and encumbrances to the Company or its distributor; and 2. The product must not have been abused, misused or improperly maintained and/or repaired during such period; and 3. Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear. THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. The Companys maximum liability hereunder is limited to the purchased price of the product. In no event shall the Company be liable for any consequential, indirect, incidental or special damages of any nature arising from the sale or use of the product, whether based in contract, tort, strict liability or otherwise. Note: Some states do not allow limitations on incidental or consequential damages or how long an implied warranty lasts, so that the above limitations may not fully apply. This warranty gives specific legal rights and you may also have other rights which may vary from state to state. This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Copyright 2013 Linear Corporation 235512 X8 4 FOLLOW THE ON-SCREEN INSTRUCTIONS TO TEST THE DETECTOR WITH THE HUB PLATE TEMPERED 1/8 TO 1/4 (3.2 mm TO 6.4 mm) 1/8 TO 1/4 (3.2 mm TO 6.4 mm) GLASS TYPE MINIMUM TO MAXIMUM THICKNESS SEALED, INSULATING 1/8 TO 1/4 (3.2 mm TO 6.4 mm) Z-Wave is a registered trademark of Sigma Designs Inc. and/or its subsidiaries. WHEN INSTRUCTED, PRESS THE BUTTON ON THE DETCTOR 3 TIMES