all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
user manual | Users Manual | 1.43 MiB | ||||
1 2 | Cover Letter(s) | December 04 2019 | ||||||
1 2 | Cover Letter(s) | December 04 2019 | ||||||
1 2 | ID Label/Location Info | December 04 2019 | ||||||
1 2 | Test Report | December 04 2019 | ||||||
1 2 | External Photos | December 04 2019 | ||||||
1 2 | Internal Photos | December 04 2019 | ||||||
1 2 | Test Setup Photos | December 04 2019 | ||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info |
1 2 | user manual | Users Manual | 1.43 MiB |
uniFLOW Release Station Installation & Configuration Manual Versioning Document Versioning Version Date Author(s) Reviewer(s) 1.0 03-Sep-2014 1.1 05-Sep-2014 1.2 08-Sep-2014 1.3 17-Sep-2014 Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Oliver Shikaloski, Holger Bauszus, Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer 1.4 06-Oct-2014 1.5 08-Oct-2014 1.6 20-Jan-2015 1.7 29-Apr-2015 1.8 08-Jun-2015 1.9 15-Oct-2015 1.10 22-Mar-2016 1.11 26-Apr-2016 1.12 03-Aug-2016 1.13 03-Nov-2016 2.0 10-Feb-2017 2.1 16-Aug-2017 2.2 16-Aug-2017 2.3 08-Dec-2017 Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Sebastian Husnik Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer, Holger Bauszus Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Thomas Lemmer Document Name uniFLOW Release Station - Installation & Configuration Knowledgebase MOMKB-770 (https://web.nt-ware.net/its/browse/MOMKB-770) File Name uniFLOW Release Station - Installation & Configuration - V2.2.pdf Technologies Concerned uniFLOW Release Station HID uniFLOW Release Station Hitag uniFLOW Release Station Multi uniFLOW Release Station PLUS uniFLOW Release Station PLUS-2 V2 uniFLOW Release Station Touch uniFLOW uniFLOW Online Short Summary This document describes the installation and configuration of the uniFLOW Release Station. Document Version Topic(s) Changes Changes 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Configuration (on page 6), Network Configuration (see "Network" on page 19), Firmware Update (on page 24), Factory Reset (on page 24), Job Release via uniFLOW Release Station (see "Job Release" on page 25) Added note that IPv6 is not supported. Added note about USB drive file system (FAT, FAT32). Updated cost center search description. Card Reader (on page 16) Added PLUS card reader configuration instructions. Mounting Options (on page 35) Corrected a link. Card Reader (on page 16) Added MiCard PLUS config tool download instructions. FCC and IC Compliance Notes (see
"Compliance and Disposal Notes" on page 35) Updated IC Notes. Configuration (on page 6) Added note about network cable connection. Info Screen (on page 27) Added description of info screen. Firmware Update (on page 24) 1.9 Specific Settings (on page 10) 1.10 Release Station (see "uniFLOW Release Station" on page 14) Added information on where to download the newest firmware. Added Printed Queue Parameter
(uniFLOW V5.4, firmware 1.0 SR4 only). Added new parameter Server Ping Interval for Emergency Access
(seconds). 1.11 uniFLOW Release Station Website (on page 12) Settings (on page 23) Logout (on page 23) Factory Reset (on page 24) Described new login screen. Described new settings page. Described new logout page. Updated Factory Reset infos. 1.12 uniFLOW Release Station Website (on page 12) Updated URL. 1.13 Specifications (on page 28) uniFLOW Online (on page 20), Network (on page 19), uniFLOW Release Station Website (on page 12) uniFLOW Online (on page 20) Reformatted chapter, moved to end of book, added disposal note. Added firmware V1.1 features:
uniFLOW Online connectivity, proxy configuration, HTTPS support, changed screenshots. Firmware V1.2: Added wizard based adding to uniFLOW Online. Firmware Update (on page 24) Added a more detailed description. Various topics Added uniFLOW Release Station MiCard PLUS-2 V2 2.0 2.1 2.2 2.3 Disclaimer NT-ware Systemprogrammierungs-GmbH, all its affiliates, partners and licensors disclaim all warranties, including, but not limited to, warranties about the accuracy or completeness of statements of this site's/document's content or the content of any site or external sites for a particular purpose. This site/document and the materials, information, services, and products at this site/document, including, without limitation, text, graphics, and links, are provided 'as is' and without warranties of any kind, whether expressed or implied. All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the prior written permission of NT-ware Systemprogrammierungs-GmbH (hereinafter also referred to as NT-ware). Company and product names mentioned herein are registered or unregistered trademarks of their respective companies. Mention of third-party products is for information purposes only and constitutes neither an endorsement nor a recommendation. NT-ware assumes no responsibility with regard to the performance or use of these products. Also, NT-ware makes no claim to these trademarks. Any use of trademarks, logo, service marks, trade names, and product names is prohibited without the written permission of the respective owners. Adlib, Express and Express Server are either registered trademarks or trademarks of Adlib Publishing Systems Inc.; Adobe, Adobe Reader, Acrobat, Distiller, PostScript and products of the CREATIVE SUITE(S) are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries; Android is a trademark of Google Inc.; Apple, the Apple logo, Mac, Mac OS, Macintosh, iPhone, iPad and AirPrint are trademarks of Apple Inc. registered in the U.S. and other countries; Box of Box Inc.; Blackboard Transact of Blackboard Inc.; CANON, imageRUNNER, imageRUNNER ADVANCE, MEAP, CPCA, AMS, iW AMS, iW Desktop, iSend, iW SAM are trademarks or registered trademarks of Canon Inc.; CardSmith is a trademark of CardSmith LLC; CBORD CS Gold of the CBORD Group Inc.; Crystal Reports and other Business Objects products and services mentioned herein as well as their respective logos are trademarks or registered trademarks of Business Objects Software Ltd. Business Objects is an SAP company; Dropbox of Dropbox Inc.; eCopy, eCopy ShareScan and eCopy ScanStation are marks or trademarks of Nuance Communications, Inc.; Evernote of Evernote Corporation; FileNet of IBM Corporation; FoxitSDK and Foxit Reader of Foxit Corporation; Google Docs of Google Inc.; Google Cloud Print web printing service is a trademark of Google Inc.; Helix Production Workflow is a trademark of NT-ware Systemprogrammierungs-GmbH; HP, HEWLETT-PACKARD, PCL and LASERJET are registered trademarks that belong to Hewlett-Packard Development Company; KONICA MINOLTA is a registered trademark of KONICA MINOLTA Inc.; iOS of Cisco Technology Inc.; iDRS SDK and IRISConnect are unregistered trademarks of I.R.I.S. Group S.A.; JAWS pdf courier are trademarks of Global Graphics SA.;
Microsoft, Windows, Windows Server, Internet Explorer, Internet Information Services, Microsoft Word, Microsoft Excel, Microsoft SharePoint, Microsoft SharePoint Online, OneDrive, One Drive for Business, SQL Server, Active Directory, Hyper-V are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries of Microsoft Corporation; Neevia Document Converter Pro of Neevia Technology; NetWare, Novell, Novell eDirectory of Novell Inc. are registered/unregistered trademarks of Novell Inc. in the United States and other countries; MobileIron of Mobile Iron Inc., Oc, Oc PlotWave, Oc ColorWave and PRISMA are trademarks or registered trademarks of Oc-Technologies B.V. Oc is a Canon company, OpenOffice.org of Oracle Corporation;
PAS is a trademark of Equitrac Corp.; PosterJet is copyrighted and an internationally registered trademark of Eisfeld Datentechnik GmbH & Co. KG; RedTitan EscapeE of RedTitan Limited; NETAPHOR, SiteAudit are trademarks of NETAPHOR SOFTWARE Inc.; SAMSUNG is a trademark of SAMSUNG in the United States or other countries; Therefore, Therefore Online of Therefore; UNIX is a registered trademark of The Open Group; uniFLOW, uniFLOW Serverless Secure Printing, Helix Production Workflow, MIND, microMIND, MiCard and uniFLOW Service for AirPrint are registered trademarks of NT-ware Systemprogrammierungs-GmbH; pcProx, AIR ID are registered trademarks of RFIdeas Inc.Readers;
CASI-RUSCO is a registered trademark of ID Card Group; Radio Key is a registered trademark of Secura Key; GProx II is an unregistered trademark of Guardall; HID ProxHID is a registered trademark of HID Global Corporation; Indala is a registered trademark of Motorola; ioProx is an unregistered trademark of Kantech; VMware vSphere and VMware vSphere Motion are registered trademarks of VMware; Xerox, Xerox and Design, as well as Fuji Xerox and Design are registered trademarks or trademarks of Xerox Corporation in Japan and/or other countries. All other trademarks, trade names, product names, service marks are property of their respective owners and are hereby acknowledged. While every precaution has been taken in the preparation of this document, NT-ware assumes no responsibility for errors or omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it. NT-ware does not assume any responsibility or liability for any malfunctions or loss of data caused by the combination of at least one NT-ware product and the used operation system and/or third-party products. In no event shall NT-ware be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document. In addition, this manual provides links to the sites of affiliated or independent companies and certain other businesses. NT-ware is not responsible for examining or evaluating, and NT-ware does not warrant the offerings of, any of these businesses or individuals or the content of their websites. NT-ware does not assume any responsibility or liability for the actions, product, and content of all these and any other third parties. You should carefully review their privacy statements and other conditions of use. Friday, December 08, 2017, Bad Iburg (Germany) Important Note Serious problems might occur if you modify the registry of your Windows operating system incorrectly. These problems might require that you reinstall the operating system. We strongly recommend to always back up the registry of your Windows operating system before applying changes to it, just in case you do something wrong. NT-ware does not assume any responsibility or liability for any impact on the operating system after changing the registry. You understand and accept that you use this information and modify the registry of your Windows operating system at your own risk. uniFLOW and corresponding components like Web Submission and Internet Gateway rely heavily on their SQL databases. We strongly suggest that you refrain from modifying these SQL databases manually without prior consultation from the NT-ware support team. NT-ware does not assume responsibility or liability for possible impact on your uniFLOW environment after modifying any of the SQL databases. Copyright and Contact NT-ware Systemprogrammierungs-GmbH Niedersachsenstrae 6 49186 Bad Iburg Germany www.nt-ware.com Tel: +49 - 54 03 - 7243 - 0 Fax: +49 - 54 03 - 78 01 03 Email: info@nt-ware.com Register of Companies: Amtsgericht Osnabrck No. of entry in Register of Companies: HRB 110944 Chief Executive Officer: Karsten Huster Responsible according to 6 MDStV: Karsten Huster VAT registration no. according to 27 a Umsatzsteuergesetz: DE 230932141 1998-2017 NT-ware Systemprogrammierungs-GmbH. Feedback Should you come across any documentation@nt-ware.com or use the Send feedback here button of the uniFLOW Online Help. relevant errors or have any suggestions please contact Technical Support First technical support services will be provided by your dealer. Before you contact the dealer for technical support, ensure you have read this document. How to use this Document Text Styles This style is used for text that is displayed on screen. This style is used for text the user has to type in. This style is used for hyperlinks to web pages, internal links to other pages in this manual. This style is used for code examples: XML code, variables or regular expressions. Pictograms Important Note:
Information that is crucial for the correct functioning of the uniFLOW software. Further Information:
Pointer to additional manuals, installation manuals, white papers or the NT-ware Knowledgebase. Region Specific Feature:
Indicator for uniFLOW features that are not available worldwide. External Link:
Link to an external web page. Settings:
Detailed explanation of configuration settings or operational procedures. Compass:
Path to the menu or configuration page in the software. Screenshots and Diagrams This manual contains screenshots of the software, diagrams explaining relations and pictures of products. Even though all visuals are up-to-date at the time of writing, they are subject to change. Language and Translations This document has originally been written in English language. Translations of this document are based on the English original. Some screenshots, diagrams and pictures in this document may not be translated and appear in English language only. Send Feedback Should you come across any documentation@nt-ware.com or use the Send feedback here button of the uniFLOW Online Help. relevant errors or have any suggestions please contact About this Document This document is delivered as part of the device / the software from NT-ware. Please read this document before using the device / the software and keep this document or the link to an online version of this document for future reference. Please make sure that all persons operating the device / the software are familiar with this document. Please observe all instructions given in this document. Installation, configuration and maintenance must only be performed by sufficiently qualified personnel. Failure to comply with this document may void the warranty. Every effort has been made to ensure that the contents of this manual are accurate. However, NT-ware reserves the right to make changes without notice. uniFLOW Release Station Contents Contents 1 2 3 4 5 6 7 8 8.1 8.1.1 8.2 8.2.1 8.2.2 8.2.3 8.2.3.1 8.2.4 8.2.5 8.2.6 8.2.7 8.2.8 8.2.9 8.2.10 8.3 8.4 8.5 9 10 11 Introduction ............................................................................................... 1 Available Models ........................................................................................ 2 Scope of Supply .......................................................................................... 2 Ports ........................................................................................................... 3 LED / Beep Status ....................................................................................... 4 Copy Control Cables.................................................................................... 5 Installation ................................................................................................. 6 Configuration ............................................................................................. 6 Advanced Configuration ................................................................................................ 8 Specific Settings ........................................................................................................................... 10 uniFLOW Release Station Website ............................................................................... 12 uniFLOW Release Station ............................................................................................................. 14 Card Reader ................................................................................................................................. 16 Port Configuration ....................................................................................................................... 16 Signal Interpreter ................................................................................................................................. 17 Network ....................................................................................................................................... 19 Support ........................................................................................................................................ 20 Upgrade ....................................................................................................................................... 20 uniFLOW Online ........................................................................................................................... 20 About ........................................................................................................................................... 22 Settings ........................................................................................................................................ 23 Logout .......................................................................................................................................... 23 MiCard Configuration .................................................................................................. 23 Factory Reset .............................................................................................................. 24 Firmware Update ........................................................................................................ 24 Job Release ............................................................................................... 25 Info Screen ............................................................................................... 27 Specifications ........................................................................................... 28 11.1 Supported Card Standards........................................................................................... 30 11.2 Mounting Options ....................................................................................................... 35 11.3 Compliance and Disposal Notes ................................................................................... 35 I uniFLOW Release Station Contents 12 Index ........................................................................................................ 41 II uniFLOW Release Station 1 Introduction The uniFLOW Release Station is an easy to use external terminal with touch screen and embedded card reader that can be used for releasing personal secure print jobs from any device as well as for print & copy accounting. Copy accounting can only be used on devices for which a copy control cable has been developed and produced. For a list of available copy control cables, please refer to chapter Copy Control Cables
(on page 5). Specifications 5.7 inch capacitive multi-touch screen. Integrated MiCard contactless card readers or model without card reader for PIN code or credentials authentication. Integrated two port network switch. For a use in projects, the uniFLOW Release Station is furthermore equipped with:
A USB port for connecting external MiCard card readers via USB. MiCard Magnetic Card Reader is not supported at the moment. An I/O connector for controlling and monitoring copying devices via copy control cable. 1 uniFLOW Release Station 2 3 Available Models The uniFLOW Release Station is available in versions with integrated MiCard card readers and in a version without integrated card reader. Available Models uniFLOW Release Station Hitag uniFLOW Release Station HID uniFLOW Release Station Multi uniFLOW Release Station PLUS uniFLOW Release Station PLUS-2 V2 uniFLOW Release Station Touch integrated card reader)
(with MiCard Hitag reader)
(with MiCard HID reader)
(with MiCard Multi reader)
(with MiCard PLUS reader)
(with MiCard PLUS-2 V2 reader)
(PIN code or credentials only; without Scope of Supply The uniFLOW Release Station package includes:
A patch cable to connect the device to a printer. Power supply. The uniFLOW Release Station Installation Guide. The uniFLOW Release Station device. 2 uniFLOW Release Station 4 Ports 1. Network port 1:
To connect the uniFLOW Release Station to the printer or to the network. 2. Network port 2:
To connect the uniFLOW Release Station to the printer or to the network. 3. USB port:
Used to connect an additional MiCard USB card reader to the uniFLOW Release Station. 4. Copy Control port 1:
To connect a copy control cable. 5. Copy Control port 2:
To connect a copy control cable. 6. RJ45 port:
Only for internal use. 7. Power input jack:
To connect the external power supply. 3 uniFLOW Release Station 5 LED / Beep Status The uniFLOW Release Station is equipped with either three, one or no LEDs, depending on what model is used. uniFLOW Release Station Hitag/HID/Multi The uniFLOW Release Station Hitag/HID/Multi is equipped with 3 status LEDs: green
(left), yellow (middle) and red (right). The table below shows the status information given by the respective LED. Status Green LED Yellow LED Red LED Booting up flashing Not synchronized Synchronized (operating) Authentication OK Authentication failed on flashing flashing flashing flashing flashing on The uniFLOW Release Station Hitag/HID/Multi is equipped with a little beeper which emits different beep tones for different statuses. The table below shows the status information given by the beeper. Status The card reader is booting up. The card reader is not parameterized which means, there was no saved config found. Beep Signal 2 x fast 2 x slow The card reader is parameterized. A configuration was found on the device. 1 x short If parameters are sent to the card reader. A card has been detected. 2 x slow 1 x long If a Facility Code has been detected as invalid. 3 x fast uniFLOW Release Station PLUS / PLUS-2 V2 The uniFLOW Release Station PLUS / PLUS-2 V2 is equipped with 1 status LED that can show three colors: Green, Yellow and Red. The table below shows the status information given by the LED. 4 uniFLOW Release Station Status LED color/Beep Booting up yellow, then green with beep Not synchronized flashing yellow Synchronized (idle) steady red Reading/Hold green with beep uniFLOW Release Station Touch The uniFLOW Release Station Touch does not have any LEDs. Neither does it have a beeper. Network Port LED (all models) Status LED color A link to a network is established. green A link to a network is established and data is transmitting. green flashing The network speed is 100 Mbit/s. yellow ON The network speed is 10 Mbit/s. yellow OFF 6 Copy Control Cables A copy control cable is needed to make use of uniFLOW copy accounting and device lock options. The cables are developed by NT-ware to make them fit to the uniFLOW Release Station. Copy control cables are sold separately and are not included by default with the uniFLOW Release Station. Copy control cables have to be configured via the PORTS.ini file. For more information, refer to chapter Port Configuration (on page 16). This is not necessary, if the uniFLOW Release Station is connected to uniFLOW Online. For a detailed list of all available copy control cables, please refer to the NT-ware DIF Portal (http://difportal.nt-ware.net) or to the NT-ware Accessory Guide which can be found on the NT-ware Partner Site (https://web.nt-ware.net/partner/). 5 uniFLOW Release Station 7 Installation Required Components uniFLOW Release Station. Power supply for the uniFLOW Release Station. Printer. Network cable (delivered with the uniFLOW Release Station). Optional Components Copy control cable for the manufacturer and model of your device. Please refer to the NT-ware DIF Portal (http://difportal.nt-ware.net) or to the Accessory Guide on the NT-ware Partner Site (https://web.nt-ware.net/partner/) for more information about which copy control cable is required for your specific machine(s). Installation 1. Switch off the desired printer. 2. Disconnect the printer from the network. 3. Attach network cable of the printer to one of the two network ports. 4. Optional: In case copy accounting is required on an MFP: Attach the uniFLOW Release Station with the respective copy control cable to the MFP. Connecting the copy control cable to your MFP might require additional installation steps. 5. Attach the uniFLOW Release Station to the network. 6. Attach the power supply to the uniFLOW Release Station. 7. The uniFLOW Release Station boots up. 8. Switch on the printer. The uniFLOW Release Station is now ready for more advanced configurations. For the uniFLOW Release Station configuration, see chapter Configuration (on page 6). Configuration The uniFLOW Release Station works without any additional configuration if your network has a DHCP server configured to provide an IP address. 6 8 uniFLOW Release Station If no DHCP is available, the uniFLOW Release Station obtains an IP address from the link-local block (for IPv4 169.254.0.0/16, for IPv6 the fe80::/10 prefix). You can use this IP address to access the uniFLOW Release Station website and assign the correct IP address manually. uniFLOW Release Station does not support IPv6 at the moment. IPv6 can only be used for a temporary link-local address for configuration purposes. Any further use of IPv6 is not supported. Please make sure to attach the network cable to the uniFLOW Release Station before switching it on. 1. After the uniFLOW Release Station has been successfully connected to the network of the uniFLOW server, it will display its assigned IP address:
2. The uniFLOW Release Station has now to be assigned to a Secure Print - Output Printer in uniFLOW. To do so, the Secure Print - Output Printer with uniFLOW Release Station printer wizard has to be used:
a. Go to uniFLOW Server Configuration > Printer/ Scanner > Wizard. b. Select the Secure Print - Output Printer with uniFLOW Release Station. c. Follow the steps of the wizard. Make sure to have IP addresses of the Release Station and the printer at hand. 3. After the uniFLOW Release Station has been successfully configured in uniFLOW, it will display the login screen of the login method you chose during the wizard. The uniFLOW Release Station is now ready to use. The uniFLOW Release Station does not require any separate license to be purchased in order to work with uniFLOW and RPS. The uniFLOW Release Station uses TCP port 8000 for discovery and EAI communication with uniFLOW. Make sure this port is open in both directions if you have any connection problems. 7 uniFLOW Release Station 8.1 Copy accounting can only be used on devices for which a copy control cable has been developed and produced. For a list of available copy control cables, please refer to chapter Copy Control Cables
(on page 5). Advanced Configuration If you want to change the configuration of the uniFLOW Release Station after you have run the wizard, you can do so simply by running the wizard again. Alternatively, you can change the settings configured during the wizard under Connections > Agents/Terminals > EAI. The sections relevant for the uniFLOW Release Station are General Information, List view and the Network Configuration. General Configuration Here you can define a global behavior that applies to all uniFLOW Release Stations connected to the uniFLOW server. To configure the global behavior, expand the select box next to Please select one of the embedded applets to change its configuration and choose uniFLOW Release Station. The options are the same as explained in chapter Specific Settings (on page 10). 8 uniFLOW Release Station The general configuration set here is only used, if no settings are made under Specific Settings (on page 10) for the corresponding uniFLOW Release Station. List View This section lists all configured EAI devices in uniFLOW. The uniFLOW Release Station is listed here as well. The uniFLOW Release Station can be configured by clicking the button. This will open a new window with device specific settings. Please refer to the chapter Specific Settings (on page 10) for a detailed explanation of these options. Network Configuration Here you can configure the IP address of the uniFLOW Release Station. IPs:
Currently configured EAI devices and their IP addresses. Discovering Server:
Leave at default (All) unless you want to limit EAI discovery to single servers. Device:
IP address of the uniFLOW Release Station. EAI Server:
http://<uniFLOW_Release_Station>:8000/mom/eai.htm Update interval in sec.:
The interval in which EAI devices are being detected by uniFLOW or an RPS. 9 uniFLOW Release Station 8.1.1 Specific Settings The uniFLOW Release Station specific settings can be changed under Connections >
Agents/Terminals > EAI > List view. Click on the Station entry. General:
button of the uniFLOW Release Select the main functionality for the uniFLOW Release Station. You can select more than one functionality at the time by holding the shift key and selecting with the mouse. o PrintJobRelease:
Allows the uniFLOW Release Station to access your secure printing queue and release your print jobs. o CardReader:
Not applicable for uniFLOW Release Station. o DeviceLock:
Allows the uniFLOW Release Station to lock the device until the user logs in. o PrintedQueue:
Device Lock is only available, if a copy control cable is used. Users can see new, not yet printed jobs and already printed jobs in different queues (called New Jobs and Printed Jobs). When pressing the Print+Keep button, the document is printed and moved to the Printed Jobs queue. The Printed Jobs queue additionally displays the time and date the job was printed. Authentication:
Select the desired authentication method here. o PIN:
The user is asked to enter their PIN code. At the moment, only numeric PIN codes can be entered on the uniFLOW Release Station. o Username/Password:
The user is asked to enter their Username/Password. o CardReader:
The user is asked to swipe their card. o CardReader with PIN:
The user is asked to swipe their card. Alternatively, the user can login with their PIN code by hitting the PIN Code button. o CardReader with Username/Password:
The user is asked to swipe their card. Alternatively, the user can login with their user name and password by hitting the AD Login button. Cost Center Selection:
Tick the checkbox if you want to give users the possibility to select a cost center on the uniFLOW Release Station after having logged in. Change Cost Center without Logout:
If checked, the users can change their cost centers without the necessity to 10 uniFLOW Release Station previously log-out. To change a cost center, the user has to touch the Change Cost Center button. Card Registration Method:
If you have unknown cards in the system and you are using a Card Reader for the authentication, you can select a card registration method here. This can either be via UserName/Password or via TIC (Temporary Identification Code). Accounting:
Not applicable for uniFLOW Release Station. On Server Failure:
Here you decide what can be done if the device becomes inaccessible in case of a server failure. There are five options:
o None o Lock Device o Unlock Device with Account o Only Emergency Accounts o Emergency & Cached Accounts:
During server or network failure the Username/Password login type is not available. Refer to chapter Emergency Account Access for setup information. 11 uniFLOW Release Station On Network Failure:
Here you have the same options as with On Server Failure. 8.2 uniFLOW Release Station Website The uniFLOW Release Station website contains general information and configuration options about the device like its firmware version, its serial number and its current IP address. The login screen for the website can be accessed under:
http://<uniFLOW_Release_Station>:8002/login.htm Firmware versions V1.1 or higher use HTTPS in order to be compatible with uniFLOW Online and automatically redirect to:
https://<uniFLOW_Release_Station>:8442/login.htm Login Page The login page exists since firmware version V1.0 SR4. 12 uniFLOW Release Station If your uniFLOW Release Station still has an older firmware version installed, the website can be accessed under:
http://<uniFLOW_Release_Station>:8002/config.htm Enter your User Name and Password and click Login to access the uniFLOW Release Station configuration website. The standard user name is administrator, the standard password is password. You should change these after the first login on the Settings (on page 23) page. If you have checked the parameter Authentication for Config Settings on uniFLOW Server? on the Settings (on page 23) page, you have to login using uniFLOW user credentials. Administrator Login Only Only administrator users with the ACL feature Administer enabled in uniFLOW can login to the uniFLOW Release Station website when uniFLOW Server Authentication is used. 13 uniFLOW Release Station After login, you will be automatically transported to the uniFLOW Release Station web page. The following chapters explain the different web pages. 8.2.1 uniFLOW Release Station The uniFLOW Release Station site gives information about the following:
Serial Number:
This is the serial number of the uniFLOW Release Station itself. It is used to select a uniFLOW Release Station during the printer wizard. You will also find this number on a sticker on the back of each uniFLOW Release Station. The serial number of the uniFLOW Release Station is derived from its MAC address
(without colons and leading zeros). Software Version:
The current firmware version of the uniFLOW Release Station. Last ID (raw):
This option is only displayed if Restrict HTTP Access to IP is set. It shows the last read card number without code conversion (raw data). Name:
You can change the default name of the uniFLOW Release Station for an easier identification of the device itself, for example the name of the associated printer. The name will also appear as Model name under the List view of the uniFLOW EAI settings. The preconfigured default name is "uniFLOW Release Station". Restrict HTTP Access to IP:
Only the computer with the IP address entered here is able to open the websites of the uniFLOW Release Station. If this IP address is not the uniFLOW server, then you are not able to access the websites from the uniFLOW server. However, this does not affect necessary communication between the uniFLOW server and the uniFLOW Release Station. If left blank, there is no access limitation. 14 uniFLOW Release Station Session timeout (seconds):
Specify the time it takes for the uniFLOW Release Station to automatically log out if a user has logged in and does not touch the screen and the device is not used. Server Ping Interval for Emergency Access (seconds) (default: 60):
The time interval in which the uniFLOW Release Station checks if the network and/or uniFLOW Server is still available. This parameter is only active if emergency behavior has been configured under uniFLOW Server Configuration > Connections
> Agents/Terminals > EAI > uniFLOW Release Station. For more information refer to topic Specific Settings (on page 10). Language:
Specify the language of the uniFLOW Release Station on-screen UI. This setting is independent from the UI language set in uniFLOW or uniFLOW Online. The default language is English. Languages if connected to uniFLOW Online If connected to uniFLOW Online, the uniFLOW Release Station currently only supports the following languages:
English French Italian German Spanish Simplified Chinese Any other language falls back to English. Save & Reboot:
Saves the settings and restarts the uniFLOW Release Station to apply them. Restart required after changes A restart of the uniFLOW Release Station is necessary in order for the settings to be applied. The login screen is updated once the language strings have been downloaded. 15 uniFLOW Release Station 8.2.2 Card Reader If you own a uniFLOW Release Station PLUS / PLUS-2 V2, you can upload a MiCard PLUS / MiCard PLUS-2 V2 configuration file here in order to configure the build-in card reader with specific settings. The configuration file can be created using the MiCard PLUS configuration utility (pcProxConfig.exe):
1. Download the newest version of the MiCard PLUS / MiCard PLUS-2 V2 configuration utility.
-
and Installation Configuration To download the file, please refer to MANUAL - uniFLOW Release Station
(MOMKB-770
(https://web.nt-ware.net/its/browse/MOMKB-770)) the NT-ware Knowledgebase. Please note that registration is required in order to access the NT-ware Knowledgebase. Access to the NT-ware Knowledgebase is limited to trained Canon personnel only. If you require the above document and you do not have access to the NT-ware Knowledgebase, please contact your Canon partner. in Install and run pcProxConfig.exe. 2. 3. Select File > Save USB device hex raw data to (SDK) file ... The option Save USB device hex raw data to (SDK) file ... is only available in the new versions of the pcProxConfig.exe. 4. Save the configuration text file. 5. On the uniFLOW Release Station Card Reader site, browse for the configuration text file and click Upload & Configure. For more information, please refer to chapter MiCard Configuration in the uniFLOW User Manual. Upload & Configure:
Uploads the configuration file to the uniFLOW Release Station and applies the settings. 8.2.3 Port Configuration This chapter is only relevant if your uniFLOW Release Station is connected to uniFLOW. If your uniFLOW Release Station is connected to uniFLOW Online, the correct port configuration is automatically downloaded from uniFLOW Online and uploaded to the uniFLOW Release Station. Manually uploading a PORT.ini has no effect. The Port Configuration site allows you to change the DIPORT settings. This is necessary if you use a copy control cable for features such as device lock and copy accounting. 16 uniFLOW Release Station These can be changed by uploading a certain configuration file (PORT.ini). Please refer to chapter Signal Interpreter (on page 17) in the installation manual for more information about how to create such a configuration file. 8.2.3.1 Signal Interpreter The uniFLOW Release Station signal interpreter allows the configuration of simple pattern matching rules. These include multi-click events and clock driven events while observing multiple I/O port pins in parallel. INI Configuration
[PORTS]
The Digital Input Port can be configured in the a .INI file on the uniFLOW Release Station. The general configuration is in the [PORT] section as follows:
REVERSE - Set to 1 if the bit order of the I/O port pins shall be reversed, e.g. b101000 instead of b000101. Otherwise, set to 0. This means that for example the port pin previously addressed as [DIPORT0] would then be addressed as
[DIPORT5]. INVERT - Set to 1 if the bits on the I/O port pins shall be inverted, e.g. b001000 instead of b110111. Otherwise, set to 0. 17 uniFLOW Release Station
[DIPORTn]
Each pin on the I/O port can be configured under [DIPORT0] ... [DIPORT5]. The following settings are available:
Interpreter Parameters DEBOUNCE - The number of milliseconds after a signal edge has been detected, to suspend monitoring. Helps to solve double-click problems because of signal bouncing. TIMEOUT - period since last edge after which an open multi-click sequence is terminated. A multi-click sequence is regarded as open after the first matching event. EDGE - 0 for valid signal event on rising edge, 1 for falling edge, 2 for both edges. RULEn - defines rules for pattern matching as explained below. n may be within 1 to 16. The sequence must be continuous or the rules won't be used after the discontinuity. For example if RULE1, RULE2, RULE3, RULE5 are defined, only RULE1, 2 and 3 will be used. Interpreter Rules Different Rules can be defined for each port pin in the respective [DIPORTn] sections. Rules must be defined under the port which holds the clock signal in order to trigger port events. The rule format is RULE{number}={product}: {mask}, {pattern}, {counter}, {clicks} where
{number}: 1,2,3,... up to 16. Do not use a leading 0, i.e. do not use RULE01, RULE02 but instead RULE1, RULE2
{product}: Product index which is used for click counting if the rule matches. The product index is calculated directly as mask&x if the value is set to -1, where x is the data word on the I/O port and "&" denotes the binary AND operator. The data bits in x may occur reversed or inverted or both if configured as explained under
[PORTS] above.
{mask}, {pattern}: The rule match condition holds true if mask&x = pattern, where x is the data word on the I/O port. Again, "&" denotes the binary AND operator. The data bits in x may be reversed or inverted or both if configured as explained under [PORTS] above.
{counter}: For multi-clicks the assignment of a counter index is required. The counter index may be within 0 and 15 and if not used set to -1. The counters are shared between all [DIPORTn] sections.
{clicks}: Set to 0 if multi-clicks are not used. Otherwise, give the number of clicks for this match to hold true. Note that that the numerical values in the rules (and only in the rules, not elsewhere) can be entered either in decimal (e.g. 17), binary (b10001), octal (o21) or hexadecimal
(0xd1 or $D1) format. Comments can be started after the {clicks} value with any non-whitespace character, for example '#' or ';'. 18 uniFLOW Release Station Example An example of the PORT.ini would look like this:
[DIPORT2]
DEBOUNCE=20 EDGE=0 TIMEOUT=200 RULE1=2:3,0,-1,0 #copy A4 COL RULE2=4:3,1,-1,0 #copy A3 COL RULE3=1:3,2,-1,0 #copy A4 B/W RULE4=3:3,3,-1,0 #copy A3 B/W 8.2.4 Network This page displays the network configuration of the uniFLOW Release Station. IP Address:
The IP address of the uniFLOW Release Station. Netmask:
The network mask of the uniFLOW Release Station. Gateway:
The gateway of the uniFLOW Release Station. Activate DHCP:
If checked, the uniFLOW Release Station uses DHCP to obtain IP Address, Netmask and Gateway automatically. If unchecked, you have to enter IP Address, Netmask and Gateway manually for a static IP address. Proxy Type:
Here you can configure a proxy. This is necessary if your uniFLOW Release Station has limited internet access. HTTPS internet access is needed for the uniFLOW Release Station in order to communicate with uniFLOW Online. o None:
No proxy is configured. o HTTP:
Allows configuration of an HTTP proxy. o SOCKS:
Allows configuration of a SOCKS proxy. Proxy Server:
The IP address and port of the proxy server. Bypass Proxy for:
Here you can enter comma separated IP addresses and URLs the proxy shall be bypassed for. For lists of single hosts, the port has to be added. For example:
10.128.1.34:8443,W81X64CLI-34.test.example.com:8443 For lists with wildcards, no port is needed. For example:
10.128.1.*, 10.128.5.*,10.128.10.*
19 uniFLOW Release Station Save & Reboot:
Saves the settings and reboots the uniFLOW Release Station to apply them. IPv6 Support uniFLOW Release Station does not support IPv6. 8.2.5 Support Here you can export, show and clear the log of the uniFLOW Release Station. The uniFLOW Release Station support team might request a copy of the log file, in order to solve problems more effectively. 8.2.6 Upgrade On this screen you can upload a file to update the firmware of the uniFLOW Release Station. For more information, refer to chapter Firmware Update (on page 24). 8.2.7 uniFLOW Online On this page, you can connect your uniFLOW Release Station with uniFLOW Online. Parameters Status:
Shows whether the uniFLOW Release Station is connected to uniFLOW Online. Printer:
Enter the IP address or FQDN of the printer the uniFLOW Release Station is connected to. o Obtain Printer Details via SNMP:
Check, if you want to obtain printer information like manufacturer, serial number, device name, device location and model name automatically. The printer details are forwarded to uniFLOW Online during the registration process and are prefilled automatically. Secret:
The secret value that has to be entered during the uniFLOW Online registration process. uniFLOW Online URL:
The URL of the uniFLOW Online tenant you want to connect the uniFLOW Release Station with. o Save:
Save the URL before clicking on connect. 20 uniFLOW Release Station o Connect:
Opens a new browser window with uniFLOW Online and starts the registration process. o Disconnect (only shown when connected to uniFLOW Online):
Disconnects the uniFLOW Release Station from uniFLOW Online. Response:
Here you can manually enter the uniFLOW Online registration response code, in case uniFLOW Online cannot directly connect to the uniFLOW Release Station during registration. Connecting uniFLOW Release Station to uniFLOW Online Login to uniFLOW Online as an Customer Tenant administrator. Via the uniFLOW Online Add Device Wizard (firmware V1.2 or newer required) 1. 2. Navigate to Print > Devices and click the "+" button. 3. Follow the wizard steps. Manually 1. Open https://<uniFLOW Release Station IP>:8442/uniflowonline.htm. 2. Under Printer, enter the IP address or FQDN of the printer the uniFLOW Release Station is connected to. This step is optional, you can do so in step 9 as well. 3. Check Obtain Printer Details via SNMP. This step is optional, you can also manually enter the data in step 9. 4. Under uniFLOW Online URL, enter the URL of your uniFLOW Online tenant. For example: https://exampletenant.eu.uniflowonline.com. 5. Click Save. 6. Click Connect. 7. uniFLOW Online opens in a new browser window (make sure your browser allows pop-ups for this page). Login to uniFLOW Online if necessary. 8. 21 uniFLOW Release Station 9. The AUTHORIZATION window opens. Enter all the necessary data about the printer. Most of it should be prefilled if you did not skip steps 2 and 3. 10. Under Secret Value, enter the Secret value from the uniFLOW Release Station uniflowonline.htm page. 11. Click Register to finish the registration process. If for any reason uniFLOW Online cannot send the registration response to the uniFLOW Release Station, a message with the registration response is shown after you clicked on Register. To finish the registration process, copy this response, paste it in the Response field of the uniFLOW Release Station uniflowonline.htm page and click Submit. 8.2.8 About General information about the uniFLOW Release Station and legal info. 22 uniFLOW Release Station 8.2.9 Settings Authentication for Config Settings on uniFLOW Server?:
If checked, only uniFLOW users with the ACL feature Administer enabled in uniFLOW can login to the uniFLOW Release Station website using their uniFLOW credentials (e.g. LDAP Login). The local username and password are disabled. uniFLOW Release Station has to be connected to a uniFLOW Server. Username (Local):
Here you can change the username for logging in to the uniFLOW Release Station website. Disabled, if Authentication for Config Settings on uniFLOW Server? is checked. New Password (Local):
Here you can change the password for logging in to the uniFLOW Release Station website. Disabled, if Authentication for Config Settings on uniFLOW Server? is checked. Retype New Password (Local):
Confirm your new password by retyping it here. Save:
Save your settings. 8.2.10 Logout 8.3 Click Logout to log out the currently logged in user. You are transported back to the login screen. MiCard Configuration The uniFLOW Release Station is available in versions with different integrated MiCard card readers. These card readers are preconfigured with a standard configuration and can be used in most cases without any further configuration necessary. However, if you still want to configure specific settings for the card readers, you can do so under Connections > Agents/Terminals > MiCard. The MiCard PLUS and MiCard PLUS-2 V2 reader cannot be configured in uniFLOW. Please use its configuration utility and upload a configuration file instead. For more information, refer to chapter Card Reader (on page 16). For more information about the MiCard specific settings available, please refer to chapter MiCard Configuration in the uniFLOW User Manual. 23 uniFLOW Release Station 8.4 8.5 Factory Reset It is possible to do a factory reset to the internal settings of the uniFLOW Release Station:
1. Create an empty text file with the name: ResetToFactoryDefaults.txt. 2. Copy the file to the root folder of an USB drive formatted with FAT or FAT32 file system. 3. Connect the USB drive to the uniFLOW Release Station. 4. The uniFLOW Release Station detects the USB drive and if it finds the file, it resets the settings and automatically reboots. The following settings are reset to default:
Release Station:
o Name o Restrict HTTP access to IP o Session timeout o Contact server on interval o Language Port Configuration:
o The default ports configuration file is used. Network:
o Activate DHCP Settings:
o Authentication for Config Settings on uniFLOW Server?
o Username (Local) o Password (Local) The MiCard and MiCard PLUS configuration is not covered by the factory reset. Firmware Update It is possible to update the firmware of the uniFLOW Release Station. To do so, you first have to download the newest firmware .apk file. To obtain the newest firmware .apk file, please refer to uniFLOW Release Station -
Firmware (MOMKB-816 (https://web.nt-ware.net/its/browse/MOMKB-816)) in the NT-ware Knowledgebase. Please note that registration is required in order to access the NT-ware Knowledgebase. Access to the NT-ware Knowledgebase is limited to trained Canon personnel only. If you require the above document and you do not have access to the NT-ware Knowledgebase, please contact your Canon partner. 24 uniFLOW Release Station There are two ways to update the firmware of the uniFLOW Release Station:
Via USB Drive 1. Copy the downloaded .apk to the root folder of an USB drive formatted with FAT or FAT32 file system. 2. Plug-in the USB drive while the uniFLOW Release Station app is running. The uniFLOW Release Station will detect the USB drive mounting and read the first
.apk file it finds in the root folder. 3. A pop-up window appears on the uniFLOW Release Station asking you to install the application. Select Install. 4. After installation, select Open to start the new uniFLOW Release Station firmware. Via Web Browser 1. Open http://<uniFLOW_Release_Station>:8002/upgrade.htm in a browser to access the Release Station - Upgrade web page. 2. Under Upload package, click the Browse button and select downloaded .apk file. 3. Click Upload & Install and wait until the web page displays sent. 4. A pop-up window appears on the uniFLOW Release Station asking you to install the application. Select Install. 5. After installation select Open to start the new uniFLOW Release Station firmware. You can check the new version of the firmware by hitting the top bar of the screen to open the About page. You can see the build version there. Only official NT-ware signed .apk files can be used for the firmware update. 9 Job Release The core functionality of the uniFLOW Release Station is the job release of your print jobs in the secure print queue. After you have logged in with your PIN or card and have selected your desired cost center (see below), your secure print queue is displayed. Here, the following actions are available:
Print+Delete:
Prints the selected jobs and deletes them. Delete:
Deletes the selected jobs with without printing them. Print+Keep:
Prints the selected jobs and keeps in in the queue. 25 uniFLOW Release Station Refresh:
Refreshes the jobs displayed in the secure queue. Select All:
Selects all jobs on the current page. One page can display a maximum of 100 jobs. If there are more than 100 jobs in the queue, you can scroll down and tap the arrow buttons to go to switch pages. Logout:
Logs out the currently logged in user. Simply select the desired job by tapping on it and select the appropriate action. Cost Center Selection If you enabled cost center selection during the configuration of the uniFLOW Release Station, you will be first presented with the Cost Center Selection screen after logging in. Select the desired cost center and choose one of the following actions:
Cancel:
Return to the login screen. Search:
Search for the cost center entered in the Search field on top of the screen. Clear:
Remove the search filter. Up:
Move up a cost center level. 26 uniFLOW Release Station Down:
Move down a cost center level. Select:
Proceed to the secure print queue. One page can display a maximum of 100 cost centers. If there are more than 100 cost centers, you can scroll down and tap the arrow buttons to go to switch pages. 10 Info Screen You can access an info screen with general information about the uniFLOW Release Station by touching the top bar of either the login screen or the "This application is not yet configured"-screen. The info screen provides the following relevant information:
Firmware version Serial number IP address 27 uniFLOW Release Station 11 Specifications Model:
uniFLOW Release Station HID uniFLOW Release Station Hitag uniFLOW Release Station Multi uniFLOW Release Station PLUS uniFLOW Release Station PLUS-2 V2 uniFLOW Release Station Touch Power Supply:
12 V LPS, min 1.0 A. Use a polarized plug 2.1/5.5 mm with positive wire to the inner jack. Ethernet Connector:
2x RJ-45 Ethernet connection with a built in 10/100 MBit switch. USB Connector:
USB Type A connection with USB 2.0 to connect a USB identification device. D-SUB-15:
Digital I/O Connector to lock/unlock the machine for copy accounting. D-SUB-15HD:
Digital I/O Connector to lock/unlock the machine for copy accounting. Indicators:
The uniFLOW Release Station is equipped with different LEDs depending on the built in card reader. See chapter LED/Beep Status (see "LED / Beep Status" on page 4) for more info. Display:
5.7" LCD with capacitive multi-touch and LED background lighting, 640 x 480 pixels Transmit Frequency:
uniFLOW Release Station HID: 125 kHz Dimensions:
Weight:
uniFLOW Release Station HiTag: 125 kHz uniFLOW Release Station Multi: 13,56MHz uniFLOW Release Station PLUS: 125 kHz & 13.56 MHz uniFLOW Release Station PLUS-2 V2:
125 kHz & 13.56 MHz 218 mm x 127 mm x 58 mm (8.58" x 5" x 2.28") uniFLOW Release Station HID uniFLOW Release Station Hitag 524 g (18.5 oz) uniFLOW Release Station Multi uniFLOW Release Station PLUS 525 g (18.5 oz) uniFLOW Release Station PLUS-2 V2 uniFLOW Release Station Touch 492 g (17.4 oz) Operating Temperature Range: 0 +35 C (32 +95 F) 28 uniFLOW Release Station Included Items:
uniFLOW Release Station Cover Ethernet cable Power supply 12V GT-41080 EU/UK/CN/KR/AUS Installation manual uniFLOW Compatibility:
uniFLOW and/or RPS V5.3 or higher. Safety Restrictions:
Certifications:
Use only in closed rooms. CE FCC RCM UL VCCI IC IC Cleaning Clean the device with a slightly dampened cloth that has been well wrung out. Turn off the power or unplug the device before cleaning. Never use alcohol, benzene, paint thinner, aerosol sprays or any other highly flammable substance for cleaning. Modifications Changes and/or modifications of the uniFLOW Release Station not approved by NT-ware will invalidate the users authority to operate the uniFLOW Release Station. 29 uniFLOW Release Station 11.1 Supported Card Standards uniFLOW Release Station HITAG Read unique ID number using the following standards HITAG 2, HITAG S, EM4102 and EM4150 technologies Configurable HITAG 1 technology Operating frequency 125 kHz uniFLOW Release Station HID Read transponders using the following standards PCProx technology from HID Configurable Reading out different lengths of Facility Codes and ID Codes of the PCProx technology HID cards. Operating frequency 125 kHz uniFLOW Release Station Multi Read unique ID number using the following standards MIFARE and MIFARE ultra light technologies, MIFARE DESFire (EV1), iCLASS, Inside Contactless, other ISO15693 /
ISO14443A cards/transponders. Configurable LEGIC prime, LEGIC advant Operating frequency 13,56 MHz 30 AWID Cardax*
CASI-RUSCO Deister*
DIGITAG EM 410x Farpointe Data GProx II*
HID Prox HiTag 1, S & 2 Indala (Motorola) ioProx (Kantech) Keri NXT Keri*
Nexwatch (Honeywell) Pyramid Radio Key ReadyKey Pro*
*Unique ID Advant CSN (Legic) eTag CSN HID iCLASS CSN I-Code CSN I-tag CSN ISO 14443A CSN ISO 15693 CSN MIFARE CSN uniFLOW Release Station uniFLOW Release Station PLUS 125 kHz Supported Cards 13,56 MHz Supported Cards 31 uniFLOW Release Station uniFLOW Release Station PLUS-2 V2 125 kHz Supported Cards AWID Cardax UID CASI-RUSCO CDVI Cotag Deister UID DIGITAG Dimpna UID EM 410x EM 4102 EM 4150 GProx II UID GProx II ID HID Prox HiTag 1 HiTag 2 HiTag S IDTECK (64 bits) IDTECK Alternate (128 bits) Indala (Motorola) ioProx (Kantech) Isonas Keri UID Keri NXT UID Nedap Nexwatch (Honeywell) Postech Pyramid (Farpointe Data) Radio Key ReadyKey Pro Rosslare Russwin UID Secura Key 32 uniFLOW Release Station uniFLOW Release Station PLUS-2 V2 13,56 MHz Supported Cards ISO 14443A:
LEGIC Advant CSN MIFARE Classic CSN MIFARE DESFire CSN MIFARE Ultralight CSN MIFARE Plus S, X CSN MIFARE Pro X CSN MIFARE Smart MX CSN Oyster ISO 14443B:
Cepas Pico Pass ISO 15693:
HID iCLASS CSN HID iCLASS SE/SR CSN HID iCLASS ID 33 uniFLOW Release Station 34 uniFLOW Release Station 11.2 Mounting Options There are different ways of mounting the uniFLOW Release Station. Depending on the device manufacturer and model, the uniFLOW Release Station can either be attached directly to the machine using a device bracket, be mounted on the wall or be set up on a stand pole next to the machine. Brackets are sold separately and are not included with the uniFLOW Release Station. For a detailed list of all available mounting options, please refer to the NT-ware Device Bracket Guide which can be found under Brackets/Mounting on the NT-ware Partner Site (https://web.nt-ware.net/partner/). Assembly instructions for each mounting option can be found on the NT-ware Partner Site as well. 11.3 Compliance and Disposal Notes FCC Compliance Notes (for USA) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IC Compliance Notes For all models with integrated RFID functionality (uniFLOW Release Station Hitag, HID, Multi, PLUS, PLUS-2 V2):
35 uniFLOW Release Station This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. For all models without RFID functionalty (uniFLOW Release Station Touch):
CAN ICES-3 (B)/NMB-3(B) Product Label Location The product label is permanently attached on the device housing as indicated below:
For some installations, a plastic cover will be attached that can be easily removed. Information on Disposal for Users of Waste Electrical & Electronic Equipment
(WEEE) The WEEE symbol on the product and/or accompanying documents means that used electrical and electronic equipment should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product to designated collection points, in accordance with your national legislation and the Directive 2012/19/EU. The correct disposal of this product will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. For professional users in the European Union If you wish to discard electrical and electronic equipment (EEE), please contact your dealer or supplier for further information. For disposal in countries outside of the European Union 36 uniFLOW Release Station This symbol is only valid in the European Union (EU). If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal. 37 uniFLOW Release Station 38 uniFLOW Release Station 39 Index uniFLOW Release Station Index
. INI Configuration 17 A About 22 Advanced Configuration 8 Available Models 2 C Card Reader 5, 16, 23 Compliance and Disposal Notes 5, 35 Configuration 5, 6 Copy Control Cables 1, 5, 8 D Disclaimer 7 F Factory Reset 5, 24 L LED / Beep Status 4, 28 Logout 5, 23 M MiCard Configuration 23 Mounting Options 5, 35 N Network 5, 19 P Port Configuration 5, 16 Ports 3 S Scope of Supply 2 Settings 5, 13, 23 Signal Interpreter 17 Firmware Update 5, 20, 24 Specific Settings 5, 8, 9, 10, 15 H How to use this Document 10 I Info Screen 5, 27 Installation 6 Introduction 1 J Job Release 5, 25 Specifications 5, 28 Support 20 Supported Card Standards 30 U uniFLOW Online 5, 20 uniFLOW Release Station 5, 14 uniFLOW Release Station Website 5, 12 Upgrade 20 V Versioning 3 41 NT-ware 2009-2017
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-04-12 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Class II permissive change or modification of presently authorized equipment |
2 | 2018-06-15 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2019-04-12
|
||||
1 2 |
2018-06-15
|
|||||
1 2 | Applicant's complete, legal business name |
NT-ware Systemprogrammierung GmbH
|
||||
1 2 | FCC Registration Number (FRN) |
0017918913
|
||||
1 2 | Physical Address |
Arkadenstrasse 5
|
||||
1 2 |
Bad Iburg, 49186
|
|||||
1 2 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
B******@phoenix-testlab.de
|
||||
1 2 |
k******@
|
|||||
1 2 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
WG7
|
||||
1 2 | Equipment Product Code |
URSPLUS02
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
H****** B******
|
||||
1 2 | Title |
Hardware Developer
|
||||
1 2 | Telephone Number |
+49-5********
|
||||
1 2 | Fax Number |
+49-5********
|
||||
1 2 |
h******@nt-ware.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | uniFLOW Release Station PLUS-2 V2 | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Snap ferrite Wuerth 7420711011 and 742 711 42. Class II Permissive Change disenables HID, HID SE and HID SEOS reading as documented in this filing. | ||||
1 2 | Snap ferrite Wuerth 7420711011 and 742 711 42 | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
PHOENIX TESTLAB GmbH
|
||||
1 2 | Name |
H****** B****
|
||||
1 2 | Telephone Number |
49-52********
|
||||
1 2 | Fax Number |
49-52********
|
||||
1 2 |
o******@phoenix-testlab.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 19 | 0.125 | 0.125 | ||||||||||||||||||||||||||||||||||||
1 | 2 | 15C | 19 | 13.56 | 13.56 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 19 | 0.125 | 0.125 | ||||||||||||||||||||||||||||||||||||
2 | 2 | 15C | 19 | 13.56 | 13.56 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC