Order Number
: GETEC-C1-21-525 Test Report Number
: GETEC-E3-21-029 FCC Part 15 subpart C Page 1 / 1 APPENDIX H
: USERS MANUAL EUT Type: Remote Controller FCC ID.: OZ5RCRBT1 CS-800 MANUAL 1 - Mechanical 1.1 - Pictures October 26, 2021 Page 1 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 1.2 Dimensions
- Dimensions : 80.25 x15.2mm October 26, 2021 Page 2 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com 1.3 - Materials & coloyrs CS-800 MANUAL PART NAME DESCRIPTION SPECIFICATION Material Spray Color PC+ABS / TPE (BLACK ) 1Coat' : PRIMER CLEAR 2Coat' : YMB-M-S BLACK PANTONE Cool Gray 5C TOP CASE Print Color Except For Designate Print Color PANTONE Cool Gray 9C Surface Treatment Nihon etching HN21/Semi-Gloss Material ABS (BLACK ) Surface Treatment Nihon etching HN21/Semi-Gloss Material PC+ABS / TPE(BLACK ) Surface Treatment Nihon etching HN21/Semi-Gloss 1Coat' : PRIMER CLEAR 2Coat' : YMB-M-S BLACK PC+ABS / TPE (BLACK ) 1Coat' : PRIMER CLEAR 2Coat' : YMB-M-S BLACK PANTONE Cool Gray 5C MIDDLE CASE BATTERY COVER BOTTOM CASE Spray Color MIC BUTTON KNOB Material Spray Color Print Color Surface Treatment Nihon etching HN21/Semi-Gloss 1.4 Label It is attached to the Middle case and it can be seen compartment after removing the bottom case. October 26, 2021 Page 3 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 2 - Electrical 2.1 - Electrical Characteristic Condition Bluetooth Low Energy Specification Spec 2.402 ~ 2.480 Parameter Frequency Range Channel RF Power Test channel RF Power Modulation Characteristics Carrier Frequency Offset and PAvg PMax Pmin f1 avg f2 avg f2/f1 f2min f2rate fTx-fn f0-fn f1-f0 TC-3000
(RF measuring instrument) Drift fn-f(n-5) Operating Voltage RF (Bluetooth) 2.2~3.6 LVI Voltage Low Voltage Indicate Operating current (IR) Power: 3V Operating current (RF KEY) Operating current (RF+Voice) Power: 3V Leakage current Non-directional distance RF range (distance) IR Range Direct Horizontal VOICE Voice Inspection JIG 300Hz 2KHz 3.8KHz October 26, 2021 Page 4 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com Unit
[GHz]
[Num]
[dBm]
[Num]
[dBm]
[dBm]
[dBm]
[KHz]
[KHz]
[KHz]
[KHz]
[KHz]
[KHz]
[KHz]
[V]
[V]
[mA]
[mA]
[mA]
[m]
[m]
[m]
[dB]
[dB]
[dB]
39 3.5 19
+8
-20
-20~+10 225~275 185 0.8 92.5 99 150 50 20 20 10 10
1
CS-800 MANUAL 3 - Software Specification 3.1 Pairing 3.1.1 Pairing Condition RCU can perform pairing with 1 Sound Bar. 3.1.2 Pairing (Re-pairing) Scenario Press and hold the BT button on the Sound Bar Sound Bar LED will indicate RCU pairing mode, like flashing blue. Press the RCU [Enter OSD Menu] or [Exit OSD Menu] Button for about 3 seconds to start pairing. i. If the previous pairing information remains. 1. Send un-pairing command to the Sound Bar. 2. Delete the pairing information and start pairing. After pairing starts, advertise until Advertising Time Out. ii. 1. Advertising Time Out is about 30 seconds. 2. Advertising Interval is about 30 ~ 35ms. When the Sound Bar find the new RCU, deleting the previous pairing information and pairing with the new RCU. When pairing is complete, all buttons of the RCU output RF code. 3.1.3 Reconnection (Disconnected State) After pairing, when the power of the RCU is re-applied or the BLE connection between the Sound Bar and the RCU is disconnected, it advertises every 5 seconds. When the BLE connection is disconnected, Press any RCU button to start direct advertising for 5 seconds to reconnect. 3.1.4 Factory Reset When reconnection is completed, all buttons of RCU output RF Code. Press about 5 seconds [Power] + [] Button, try the Factory Reset. In case of Factory Reset, the BLE connection between the Sound Bar and RCU is disconnected. And the pairing information of the RCU is also deleted. The RCU sends an un-pairing command to the Sound Bar before deleting the pairing information. Sound Bar receives the Un-Pairing Command Code, it deletes the pairing information. October 26, 2021 Page 5 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 3.2 Operation Mode 3.2.1 Normal Operation Mode The keys below work.
[Power]
[Smart Framing]
[Enter OSD Menu]
[Camera Preset 1]
[Camera Preset 2]
[Speaker Volume +, -]
[Zoom +, -]
[Mic Mute]
3.2.2 OSD Menu Operation Mode The keys below work.
[Mic Mute]
[Cursor Control , , , ]
[Exit OSD Menu]
[Speaker Volume +, -]
3.3 Enable Full Function
Press the RCU [Enter OSD Menu] + [Camera Preset 2] Button for about 3 seconds to start to enable full function The RCU sends an enable full function command to the Sound Bar 3.4 Couch Mode (Stuck) Any Hard Button is pressed for more than 30 seconds, Release Code is output 3.5 OTA: Over the Air (Firmware Update) 3.5.1 OTA Scenario Provide bin file for RCU OTA. Perform RCU OTA by running the App on Sound Bar. When the RCU enters the OTA mode, all buttons do not work. When the OTA is complete, the RCU reboots and attempts to reconnect. October 26, 2021 Page 6 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 3.6 Button Code 3.6.1 Button Code Table Hold operation should be implemented by checking the output of the repeated operation every 100ms in the Sound Bar October 26, 2021 Page 7 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 3.7 Battery Specification 3.7.1 Battery Level Sound Bar can read Battery Level of RCU using BLE Battery Service. The battery level is evenly divided into 10 steps in the battery voltage range from 2.50V to 3.10V. 1. +/- 0.15% tolerance Percentage (%) Table by Voltage 2. Table Voltage Percentage (%) Battery info 3.10 ~
100%
2.98 ~ 3.10 2.92 ~ 2.98 2.86 ~ 2.92 2.80 ~ 2.86 2.74 ~ 2.80 2.68 ~ 2.74 2.62 ~ 2.68 2.56 ~ 2.62 2.50 ~ 2.56
~ 2.50 90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0x0A 0x09 0x08 0x07 0x06 0x05 0x04 0x03 0x02 0x01 Cut-Off
# Scheduled to be updated upon correction after H/W measurement. 3.7.2 Operating Voltage RF Button Code output is possible up to 2.50V. 3.7.3 Cut-Off Scenario Cut-off stops the use of the remote control to prevent damage to the circuit due to low voltage. When the battery level is measured below 2.50V, the RCU operation stops. When a voltage of 2.65V or higher is applied in the cut-off state, the RCU operates October 26, 2021 Page 8 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 3.8 BLE Protocol 3.8.1 Pairing Scenario 3.8.2 Key Packet Structure CS-800 BLE Protocol consists of a total of 2 bytes.. Button Data is composed of 1 byte and means RCU Button Code. Button State is composed of 1 byte and means the pressed state of the RCU Button. 1. The state when the button is first pressed is Press State (0x01). 2. The state of pressing the button is Repeat State (0x02). A. If the button is kept pressed, the button state repeats every 100ms and the packet is repeatedly output. 3. When the button is released, the state is Release State (0x03). 3.8.3 Key Packet Example October 26, 2021 Page 9 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL When the Camera Home Button is pressed, Key Packet consisting of Button Data (0x07), Button State
(Press 0x01), output If the button is pressed continuously, only the Button State is changed to Repeat 0x02, output at intervals of 100ms. When the button is released, only the button state is changed to Release 0x03, output. October 26, 2021 Page 10 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 4 - Environmental Tests 4.1 - Temperatures Conditions
- Operating Temperature: 0C ~ +45C
- Storage Temperature: -10C ~ +60C at 95% Humidity 4.2 - Operating Tests 4.2.1 - Dry Heat Test
- Temperature: +45C
- Test Time: 72hours
- Test Quantity: 3EA 4.2.2 - Cold Test
- Temperature: 0C
- Test Time: 72hours
- Test Quantity: 3EA 4.3 - Non-Operating Tests 4.3.1 - Dry Heat Test
- Temperature: +60C
- Test Time: 72hours
- Test Quantity: 3EA 4.3.2 - Cold Test
- Temperature: -10C
- Test Time: 72hours
- Test Quantity: 3EA
- Functional Test: Take the measurements after for 1 hour at room temperature.
- Requested level: Remote Control should satisfy electrical and mechanical performances.
- Functional Test: Take the measurements after for 1 hour at room temperature.
- Requested level: Remote Control should satisfy electrical and mechanical performances.
- Functional Test: Take the measurements after keeping for 1 hour at room temperature.
- Requested level: Remote Control should satisfy electrical and mechanical performances.
- Functional Test: Take the measurements after keeping for 1 hour at room temperature. The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com October 26, 2021 Page 11 of 14 CS-800 MANUAL
- Requested level: Remote Control should satisfy electrical and mechanical performances. 5 - Certification Assesment of compliance of the product to the requirements relating to Electromagnetic Compatibility is based on the following standards
- FCC Part 15 subpart C 15.247
- EN 62368-1:2020 + A11:2020
- ETSI EN 301 489-1 V2.2.3:2019
- ETSI EN 301 489-17 V3.2.4:2020
- ETSI EN 300 328 V2.2.2:2019
- EN 62479:2010 6 - Manufacturer & Importer 6.1 - Manufacturer
- Name: Ohsung Electronics Co., Ltd. 6.2 Importer
- Name: YAMAHA
- Address: #181 Gongdan-dong, Gumi, Gyeongbuk Republic of Korea. October 26, 2021 Page 12 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 7 - Battery Management 7.1 - Caution
- Do not ingest battery, Chemical Burn Hazard
- [The remote control supplied with] This product contains a coin / button cell battery. If the coin / button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
- Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning!
Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Note: The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to operate the equipment. FCC Caution This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference October 26, 2021 Page 13 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com CS-800 MANUAL 2. This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Federal Communication Commissions (FCC) Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. October 26, 2021 Page 14 of 14 The contents of this document may not be reproduced or distributed without prior written permission of OHSUNG ELECTRONICES CO., LTD. Address: #335-4, SANHO-DAERO, GUMI, GYUNG BUK, KOREA http://www.ohsungec.com