Master Specification Wireless Barcode Scanner Product Name OPL-2724 Specification No. SS08057 Edition Initial Date of Publication Original Spec. No. SS08045 Optoelectronics Co., Ltd. 4-12-17 Tsukagoshi Warabi-shi, Saitama 335-0002 Japan TEL: +81 (0)48-446-1183 FAX: +81 (0)48-446-1184 Revision History Specification Number: SS08057 Product Name: OPL-2724 Revision Initial Date 2008/
Section
Description of Changes OPL-2724 SS08057 Table of Contents 1. Abstract.................................................................................................................................................. 1 2. Overview................................................................................................................................................ 1 3. Physical Features .................................................................................................................................. 1 4. Detailed View......................................................................................................................................... 2 5. Basic Specifications............................................................................................................................... 3 6. Electrical Specifications ......................................................................................................................... 4 7. Technical Specifications......................................................................................................................... 4 8. Interface Specifications........................................................................................................................ 10 9. Operation Specifications...................................................................................................................... 11 10. Default Settings ................................................................................................................................. 12 11. Durability ............................................................................................................................................ 14 12. Reliability ........................................................................................................................................... 14 13. Electrical Specifications ..................................................................................................................... 14 14. Regulatory Compliance ..................................................................................................................... 15 15. RoHS ................................................................................................................................................. 15 16. Display of Product Information........................................................................................................... 16 17. Packaging Specifications................................................................................................................... 18 18. Product Specification Changes.......................................................................................................... 20 19. Warranty ............................................................................................................................................ 20 20. Precautions.......................................................................................................................................... 1 21. Bluetooth.............................................................................................................................................. 2 22. Frequency Band .................................................................................................................................. 2 OPL-2724 SS08057 1. Abstract 2. Overview This manual provides specifications for the OPL-2724 wireless barcode scanner. This scanner is a laser barcode scanner which is able to detect black or colored barcodes on the white or colored back ground.
- OPL-2724 is a wireless barcode scanner.
- The use of a short-wavelength red laser beam enhances visibility when scanning lines.
- To scan a barcode, press the trigger switch without the optical window of this scanner touching the objective barcode.
- Supported symbologies are: WPC (EAN, JAN, UPC-A / UPC-E), industrial 2of5, IATA, interleaved 2of5, NW-7 (Codabar), Code-39, Code-93, Code-128, EAN-128 and MSI Plessey.
- Code options, read options and communication settings can be configured by sending commands.
- Scanned data is transferred to the designated device via wireless communication (Bluetooth V2.0).
If the OPL-2724 is disconnected because it is out of range or the Bluetooth device is not available, scanned data will be saved in the built-in memory of the scanner.
- OPL-2724 uses 2 size AAA alkali batteries for its power supply.
- This product is compliant with RoHS. 3. Physical Features 3-1. Dimensions 96 x 40 x 22 (in millimeters) Figure 1: Physical Features 3-2. Weight 50 g Max. (excluding the weight of battery)
- - 1 OPL-2724 SS08057 4. Detailed View Name Figure 2: Detailed View Function To scan barcodes and to enable or disable Bluetooth communication. To notify the status of barcode scanning, Bluetooth communication, and warnings so on. 1. Trigger Switch 2. 3-color LED (Red, Green, Blue) 3. Plastic Mask for Optical Window Optical window for laser barcode scanning. 4. Laser Scan Engine 5. Battery Cover 6. Certification Label 7. Laser Caution Label 8. Serial Label 9. Serial Barcode Label 10. Hand Strap Hole Laser scan engine to scan barcodes. To protect batteries. Label to notify the acquisition of Radio Law 38-24-1 certification. To warn about the laser beam. Label to notify the model name and other product information. Label to notify the serial number of the product. To attach the hand strap to the scanner.
- - 2 OPL-2724 SS08057 5. Basic Specifications Item Control section External memory Display section CPU Clock frequency FROM SRAM LED Function Buzzer Loudness Operation keys Scanning section Operation keys Key durability Laser wavelength Scan rate Resolution PCS Depth of field Specifications 16-bit CISC CPU 14.74 M Hz 256 KB 32 KB 3-color LED (red, green, blue) Notifies the status of barcode scanning, battery power remained, Bluetooth communication. 70 dBA or higher
(when the scanner is set to Loud)
/ enable or disable 1 key
(trigger key Bluetooth communication) 500,000 times 650 10 nm / under 1 mW 100scan/sec 0.127 mm or higher 0.45 or higher 70 to 185 mm WPC(UPC,EAN,JAN),NW-7,Code-39, industrial 2of5, interleaved 2of5, Code-93,Code-128 etc and EAN-128 LR-03 (two size AAA alkali batteries) 48 hours Ambient light immunity 50,000lx Supported symbologies Power Supply Section Main battery Battery life 1 Battery life 2 (*) Current consumption Data retention time Frequency Specifications Transmission power Comm. range 30 days or longer 1.5 mA or less 125 mA or less 48 hours Lithium secondary battery (3.4 mAh) 2400 MHz to 2483.5 MHz Bluetooth Ver2.0 compliant Class 2 compliant (Under 4 dBm ) 10 m 115.2 kbps 1/4 (surface mounted) Baud rate Antenna Operating temperature -5 to 50 deg. C
-10 to 60 deg. C Storage temperature Operating humidity 30 to 80 %
20 to 90 %
Storage humidity Water resistant IP-X2 Shock 1.5 onto a concrete floor.
(Dropped once on each of 6 sides). Air discharge: 10 kV Air discharge: 15 kV Indirect discharge: 10 kV Radio Law 38-24-1 certification Bluetooth logo certification Anti-static Others Wireless Comm. Section Environmental Conditions Regulations
* When scanning 100 times a day. (Connect Bluetooth only when transmitting data.)
- - 3 Notes For BIOS/AP For WORK/DATA Buzzer noise was estimated at a point 10 cm behind the scanner. IEC68025-1 Class 2 Resolution: 1.0 mm PCS: 0.9 or higher When scanning twice in every 10 seconds with Bluetooth ON all time. Under conditions below. In stand-by state In operating state After the discharge of main batteries. With SPP Communication range may differ due to the environments. No condensation No condensation No defects found. No malfunctions found. No destruction found. No malfunctions found. OPL-2724 SS08057 6. Electrical Specifications Item Light source Emission wavelength Light output Scan method Scan rate Scan angle Scan angle Resolution Specifications Red laser diode 650 10 (at 25 deg. CJIS C 6802 Class 1
< 1.0 (IEC60825-1 Class 2) Bi-directional scanning 100 20 54 5 44 0.127 or higher Unit nm mW Deg. Deg. mm scans / sec 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Item Conditions Ambient temperature and humidity Room temperature and humidity Ambient light Background Scan angle Light detecting angle PCS
(Note*) Barcode sample 500 to 900 lx Black 54 (scan range: 44) 40 0.45 or higher
(over 70% of reflectivity of space and quiet zones.) OPTOELECTRONICS test sample (9-digit Code-39) Resolution: 0.25 mm 90 mm from the optical window
= 0, = 15, = 0 R =
Distance Angle Curvature PCS=
Reflectance of white barReflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.
- - 4 OPL-2724 SS08057 7-1. Scan Area and Resolution Figure 3: Depth of field in millimeters. PCS 0.9 Resolution (mm) 1.0 0.5 0.25 0.15 Space 25 mm 18 mm 10 mm 7 mm Depth of Field (mm) 70 to 185 50 to 160 50 to 120 50 to 70 Details:
The depth of field is measured from the optical window of the scanner. The scan area is a circular area centered on the beam, which appears at various resolutions. Conditions:
Resolution Symbology No of Digit Barcode Sample 1.0 mm 0.5 mm 0.25 mm 0.15 mm Code-39 Code-39 Code-39 Code-39 1 3 8 10 OPTOELECTRONICS test sample, PCS = 0.9 OPTOELECTRONICS test sample, PCS = 0.9 OPTOELECTRONICS test sample, PCS = 0.9 OPTOELECTRONICS test sample, PCS = 0.9
- - 5 OPL-2724 SS08057 7-2. Pitch Angle Pitch angle: = 25 Figure 4: Pitch angle 7-3. Skew Angle Skew angle: = 50 (excluding dead zone)
- - 6 OPL-2724 SS08057 7-4. Dead Zone Dead zone: = 8
(There are some areas in which scanning may fail due to specular reflection.) Figure 5: Skew angle and dead zone
- - 7 OPL-2724 SS08057 7-5. Tilt Angle
= 20
<Conditions>
Barcode Sample: OPTOELECTRONICS test sample PCS:
Resolution:
Symbologies:
(96 mm from the optical window of the scanner.) 0.9 0.26 mm 13-digit JAN 7-6. Curvature Figure 6: Tilt angle With 8-digit JAN barcodes, decoding performance is guaranteed when R15mm. With 13-digit JAN barcodes, decoding performance is guaranteed when R20mm.
(96 mm from the optical window of the scanner.) Figure 7: Curvature
<Conditions>
Barcode Sample: OPTOELECTRONICS test sample PCS:
Resolution:
0.9 0.26 mm
- - 8 OPL-2724 SS08057 Scannable barcode width differs depending on the depth of field. Scanning performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values:
7-7. Scan Width 7-8. Ambient Light Immunity Incandescent Light: to 3,000 lx. Fluorescent Light:
to 3,000 lx. to 50,000 lx Sunlight:
Figure 8: Ambient Light Immunity 0.9
<Conditions>
In the state shown in the figure above, carried out scanning test under the conditions below:
PCS:
Resolution: 0.25 mm Symbology: 8-digit Code-39 Quiet zone: 10 mm N/W ratio: 1:2.5
(Do not cause specular reflection of the light source.) Industrial 2of5, Interleaved 2of5 7-6. Supported Symbologies
WPC (UPC, EAN, JAN)
NW-7 (CODABAR)
Code-39
Code-93
Code-128
EAN-128
MSI / Plessey Scan rate 100 scans and 100 decodes per second Ambient temperature and humidity: Room temperature and humidity Ambient light: 500 to 900 lx
- - 9 OPL-2724 SS08057 8. Interface Specifications 8-1. Wireless Specifications OPL-2724 is a Bluetooth ver2.0 + EDR compliant device supporting SPP (serial port profile). OPL-2724 uses Bluetooth as the wireless interface. Therefore, the device which communicates with the OPL-2724 must support the same SPP. Supported protocol stack RF (Radio Frequency Protocol) BB (Base Band Protocol) LM (Link Manager Protocol) L2CAP (Logical Link Control and Adaptation Protocol) SDP (Service Discovery Protocol) RFCOMM (serial port emulation)
-Supported profile GAP (Generic Access Profile) SPP (Serial Port Profile)
-Communication configuration 1 OPL-2724 to 1 Host System (Do not connect multiple scanners to one host system.)
-Operation mode of the scanner while connected to the host system Master / Slave mode
-Security mode Authentication enabled: These settings can be configured using menu barcodes.
-Encryption Encryption enabled: These settings can be configured using menu barcodes.
*Encryption will be disabled if the device which communicates with the OPL-2724 does not support the encryption features.
-Communication range Approximately 10 meters
*Communication range may differ due to the environments. 8-2. Configuration of Settings by Reading Menu Barcode Labels Communication parameter settings of OPL-2724 can be configured by scanning menu barcodes.
(Refer to the instruction manual for further information of menu barcodes)
10 OPL-2724 SS08057 9. Operation Specifications 9-1. Buzzer and LED Display OPL-2724 notifies its operation state with LED and buzzer on its head section. Overview Status Details of the Status Scanning Orange Bluetooth connect Bluetooth disconnect Trigger Key operation Color Green Red Blue Blue Red Red Red Trrr Buzzer is disconnected. has been done successfully. Light Lighting Shows that scanning of the barcode or transmission of scanned Lighting Shows that scanned data is stored in memory while the scanner Lighting Shows that the scanned data was not successfully transmitted. Blinking Shows that the scanner is making connection to Bluetooth. Blinking Shows that Bluetooth connection was made successfully. (*1) Lighting Shows that Bluetooth connection was not made successfully. Lighting Shows that Bluetooth was disconnected. Lighting Shows that the Bluetooth device is out of range or not available. Trrrrrrrrrrr Trrrrrrrrrrr Pip, Pip, Pip
Trrr, Trrr Pip, Pip, Pip Red Lighting Red Lighting Notifies that the batteries are running low every time the user presses trigger key. (*2) It is possible to scan barcodes. Notifies that the batteries are running low every time the user presses trigger key. (*3) It is not possible to scan barcodes. Pip, Pip, Pip
*1: When the scanner is automatically connected after scanning a barcode, Good Read buzzer will sound.
*2: Please prepare new batteries.
*3: Please change batteries. 9-2. Operating Time Specifications About 48 hours 30 days or longer Operating conditions Conditions
- When scanning once in every 5 seconds.
- When Bluetooth is connected all time.
- When scanning 100 times a day.
- Connect Bluetooth only when transmitting scanned data.
- Normal temperature
- Barcode sample: Code-39 (PCS: 0.9, Resolution: 0.25mm)
*The foregoing performance is guaranteed when using alkali batteries.
*OPL-2724 may not satisfy the foregoing performance due to battery degradation.
11 OPL-2724 SS08057 10. Default Settings To make it easier to configure the settings of OPL-2724 to the default settings, there are [U1] menu barcodes. For communication settings, there are [INIT] menu barcodes. At the time of shipment from the factory, all settings are configured to [U1]. ([INIT] menu barcodes are included in [U1] menu barcodes.
[U1] Default Settings 1: Supported symbologies Transmit code length Code type Reading UPC-A UPC-A Add-on UPC-E UPC-E Add-on EAN-13 EAN-13 Add-on EAN-8 EAN-8 Add-on Code-39 NW-7(Coda bar) Transmit CD Calculate CD Transmit others ST/SP Transmission Transmit as abcd/abcd Set prefix Set suffix CR CR CR CR CR CR CR CR CR CR D.2of5 I.2of5 Code-93 Code-128 EAN-128 MSI/Plessey IATA Note:
1) In the Reading column, means Enable to read and means Disable to read. 2) In the Transmit code length column, means Transmit code length and means Not CR CR CR CR CR CR CR
transmit code length. 3) In the Transmit CD column, means Transmit check digit and means Not transmit check digit. Also,- means there is no setting for check digit transmission. 4) In the Calculate CD column, means calculate check digit and means do not calculate check digit. 5) In the Setting prefix column,- means there is no setting for prefix.
12 OPL-2724 SS08057
[U1] Default Settings 2: Read, trigger and buzzer options Item Setting the number of characters Read mode Multiple read reset time Add-on wait mode Redundancy NW-7 inter-character gap check Multiple columns read Trigger switch Read time Buzzer durations Buzzer tone Buzzer loudness Indicator duration (Green LED) Default setting Fixed length OFF all codes Single read 500 msec 500 msec Read 3 time, redundancy = 2 Within 1 character Disable multiple columns read Enable trigger 2 seconds 200 msec 3 kHz + 2.5 kHz Loud 200 msec
[U1/INIT] Default Settings 3: Communication options Item Default setting Enabled BD address automatic connection setting Barcode automatic connection setting Disabled No reception memory setting Data correction mode setting Disabled Enable / Disable connection with trigger switch Enabled Trigger key for connecting hold time setting Trigger key for disconnecting hold time setting Automatic disconnection time setting Automatic re-connection valid time setting Select a sound when disconnected ACK/NACK control ACK/NACK Time required for connecting to slave mode 3 seconds 5 seconds 3 minutes Disabled Enabled Nonprocedural 1 second 2 minutes U1/INIT] Default Settings 4: Bluetooth options Item Default setting Connection mode BD address setting Authentication PIN-code label Encryption Master mode Disabled Disabled Disabled Disabled
13 OPL-2724 SS08057 11. Durability 11-1. Water Resistant and Dust-proof Features Item Water Resistant Specifications IP-X2 11-2. Anti-static Electricity Features Item Anti-static Electricity Test Specifications No malfunction Air discharge: 10 kV Air discharge: 15 kV No destruction Indirect discharge: 19 kV No malfunction IEC61000-4-2 compliant Notes 11-3. Drop Test Item Drop Test *
Conditions Dropped from a height of 150 cm onto a concrete floor. Notes Once on each of 6 sides.
*Note:
- Scratches on the scanners case are not deemed as defects.
- The scanner must perform normally after the test.
- Battery cover should not fall apart during or after the test. 12. Reliability Item MTBF Keystroke verification 13. Electrical Specifications 13-1. Absolute Maximum Ratings Section Laser scan engine
(when not ON all time) Trigger key Conditions: Press trigger key with 2kgf force. 10,000 hours 500,000 times Life Item Power Supply Vol. Specifications
-0.3 to 3.6 Unit V 13-2. Current Consumption Item Specifications In standby state 1.5 mA or less In communication 35 mA or less Conditions No Bluetooth communication No laser scanning With Bluetooth communication No laser scanning With Bluetooth communication With laser scanning Maximum current Testing conditions Power supply voltage: 3.0 V, Operating temperature: 25 deg. C 125 mA or less
14 OPL-2724 SS08057 14. Regulatory Compliance 14-1. Laser Safety JIS C 6802: 2005 Class 1 IEC825-1/EN60825-1: Laser class 1 FDA CDRH Laser class 1. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50 dated July 26, 2001. Class 1 laser devices are not considered to be hazardous when used for their intended purpose. Avoid staring into the laser beam. 14-2. Product Safety IEC60950-1 EN60950-1 14-3. EMC EN55022 EN55024 FCC Part 15 Subpart B Class B FCC Part 15 Subpart C Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : ( 1 ) this device may not cause harmful interference, and ( 2 ) this device must accept any interference received, including interference that may cause undesired operation. VCCI Class B This is a Class B product, to be used in a domestic environment, based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. 14-3. R&TTE EN300 328 EN301 489 14-4. Others Radio Law 38-24-1 Bluetooth logo certification 15. RoHS OPL-2724 is a RoHS compliant product.
*RoHS: The restriction of the use of certain hazardous substances in electrical and electronic equipment,2002/95/EC.
15 OPL-2724 SS08057 16. Display of Product Information Attach serial label, laser caution label and model name label as shown below:
Manufacturer_ID_Label OPL27247039-0-01 T C U D O R P R E S A L 1 S S A L C 1 0 0 2
2 A
1
5 2 8 0 6 C E I LR03 LR03 CLASS 1 LASER PRODUCT IEC60825-1+A2:2001 Laser_Caution_Label OPL27247032-0-00 Model_Name_Label OPL27247100-0-02 Figure 9: Product Information
16 OPL-2724 SS08057 16-1. Individual Packaging Box Label Attach a label with the information listed below to the individual packaging box. OPL2724 Model name
*OF2OPL2724*
Specification No. OPL2724 Item No.
* 1 2 3 4 5 6 *
Serisla No. (6 digits)
17 OPL-2724 SS08057 17. Packaging Specifications 17-1. Individual Packaging Specifications Put the OPL-2724 into a protective bubble bag and put it into the individual packaging box. Accessories:
Size AAA alkali batteries X 2 Hand strap
18 OPL-2724 SS08057 17-2. Individual Packaging Box Specifications Dimensions: 245 (W) x 110 (D) x 38 (H) mm Note: The Ro mark on the inner and outer packaging indicates that this product does not use any materials, components or parts that are restricted under RoHS standards (the restriction of the use of certain hazardous substances in electrical and electronic equipment, 2002/95/EC). This is an internal determination by Optoelectronics and carries no legal weight in the EU.
19 OPL-2724 SS08057 18. Product Specification Changes Any changes to the product specifications stated in this manual shall be discussed in advance. 19. Warranty 19-1. Warranty Period Optoelectronics Co., Ltd. (hereinafter Optoelectronics) warrants that this product is free of defects and malfunctions for a period of 12 (twelve) months beginning on the last day of the month in which it is shipped. Optoelectronics will repair product defects or malfunctions that arise in the course of normal usage during the twelve-month warranty period free of charge. Any repair or replacement of the product after the foregoing warranty period will be charged at regular rates. Repair or replacement of the product due to defects or malfunctions that arise as a result of customer mishandling will be charged at regular rates, even during the foregoing warranty period. Products for maintenance or repair shall be sent back to Optoelectronics. The sender is responsible for all shipping costs. 19-2. Delivery Method 19-3. Repair Timeframe Repaired products will be sent back to the customer within 20 (twenty) days of acceptance by Optoelectronics. Expedited repairs may be available, subject to terms agreed upon by Optoelectronics and the customer. 19-4. Maintenance Period The maintenance period of this product is 5 (five) years after its shipment. Optoelectronics may discontinue maintenance of this product during the 5 (five)-year maintenance period if a satisfactory replacement product or alternative maintenance solution is agreed to. 19-5. Other Any additional warranty issues must be discussed with Optoelectronics on a case-by-case basis.
20 OPL-2724 SS08057 20. Precautions 20-1. Laser-related Caution Do not stare into the laser light from a scanning window. It may harm your eyes. Do not point the laser directly at others eyes. It may harm your eyes. Do not stare into the beam with optical instruments. It may harm your eyes. 20-2. For the Radio Equipment OPL-2724, a radio equipment for low power radio station of 2.4 GHz band advanced data communication system specified in the Radio Law, has obtained the Certification for Construction Design of Specified Radio Equipment. Therefore, it does not have radio station license in Japan. The following activities are prohibited under the Radio Law:
Remodeling and disassembly Peeling off the certificate label Do not use this product for the devices or in the environments stated below:
It may cause radio interference and affect surrounding equipments, which may induce injury or physical damages. Safety and medical devices designed to protect human body Environments in which there may be serious damages to this product. 20-3. Handling Handle this product carefully. Do not deliberately subject it to any of the following:
(1) Shock Do not throw or drop the scanner. Do not squeeze the scanner between heavy items.
(2) Temperature Conditions Do not use the scanner at temperatures outside the specified range. Do not pour boiling water on the scanner. Do not throw the scanner into the fire.
(3) Foreign Materials Do not put the scanner into water. Do not put the scanner into chemicals.
(4) Other Do not disassemble this product. Do not use the scanner near a radio or a TV receiver. It may cause reception problems. Do not use the scanner near a device which generates excessive static electricity. It may cause problems. The device may not perform properly when placed near a flickering light, such as a CRT. The information in this specification is subject to change without notice. 20-4. Export Administration Regulations This product is subject to the strategically controlled exports regulated under Foreign Exchange and Foreign Trade Laws. Therefore, export of this product may require an export permission of Japanese government.
- - 1 OPL-2724 SS08057 21. Bluetooth Bluetooth is a trademark owned by its proprietor and used by OPTOELECTRONICS Co., Ltd. under license. To communicate via Bluetooth, the divice which OPL-2724 is connected to, must support the same Bluetooth version and profile. OPL-2724 is compliant to Bluetooth standards. However, we cannot assure the connection between OPL-2724 and other Bluetooth devices which have not been tested. this Bluetooth supporting devices use 2.4 GHz frequency band. However, many other sorts of the communication speed or devices also utilize communication range of this scanner. The use of OPL-2724 outside of the European Union, the United States and Canada is punishable under the law. frequency band. It may effect Communication speed and communication range of OPL-2724 may differ due to the obstcles and radio wave conditions between OPL-2724 and the divice, which OPL-2724 is connected to. Conditions of the divice, which OPL-2724 is connected to, may also effect the communication speed and communication range of OPL-2724. Expected interference distance is up to 10 meters. 22. Frequency Band The frequency band 2.4 GHz is utilized by this scanner. Read carefully the followings before using this product. In the frequency band of this scanner, scientific, medical and industrial devices including microwaves are used. Also other radio stations including local private radio station for mobile object identification requiring license for such as manufacturing lines at factories, specific power-saving radio station requiring no license and amatuer radio station are managed. 1. Please make sure that other radio stations are not managed in the frequency band 2.4 GHz before using this scanner. 2. In case that radio interference occurs between this scanner and other radio stations, change the service space immediately, or stop transmitting radiowave to avoid the interference.
*If you have any questions or troubles, please contact our marketing group. Handle product in accordance with this specification.
- - 2 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This device complies with Part 15 of FCC RF Rules. Operation is subject to the following two conditions:
1) this device may not cause interference and 2) this device must accept any interference, including interference that may cause undesired operation of the device.