CONFIDENTIAL & PROPRIETARY C005 v.0r1 Modem USER MANUAL SPRS Ready Self-contained Extended service life Highly robust communication protocol The C005 modem is an autonomous transceiver that is used primarily for the communication of identification, control and management information using RF (radio frequencies). The modem may be used in conjunction with active transponders which may be affixed to assets with which it can communicate in order to collect data. System description. The C005 system has been developed with the goal of providing the following services. Temperature monitoring Data transfer, logging and Telemetry Humidity monitoring Automated inventory management Automated fleet management Stolen vehicle tracking Alarm signal communication (CID) The use of the C005 enables automated and remote data collection. It also offers the ability to control and monitor the property on which our proprietary transceivers are affixed. This monitoring and control is done according to schedules and specific conditions that have been previously established. The modem operates using a communication protocol that is both highly secure and robust. It contains a proprietary information recovery and patterning encoding. The C005 was developed in order to minimize the use of space while also minimizing its visibility. This equipment was also developed so that it can operate with great efficiency, thus providing greater autonomy in emergency situations. One of the main criteria for the development was reduced operating cost. This is achieved by virtue of the fact that energy consumption is kept to a minimum by maximizing overall system efficiency. This device complies with Industry Canadas licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Please note: The minimum separation distance between the device's antenna and all persons during normal operation is 25 centimeters. Warning: Any changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment. Do not attempt to tamper or make any changes to this device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Avertissement RF conformit de lexposition. Lantenne (s) utilise pour cet metteur doit tre installe pour fournir une distance de sparation dau moins 25 cm de toutes personnes et ne doit pas tre situ proximit ou fonctionner en conjonction avec une autre antenne ou metteur. Tout changement ou modification non expressment approuv par la partie responsable de la conformit risque dinvalider lautorisation accorde lutilisateur dutiliser cet appareil. Les utilisateurs et les installateurs doivent recevoir des instructions dinstallation de lantenne et des conditions de fonctionnement du transmetteur satisfaisant le respect de lexposition aux RF. Caracteristics Rugged reinforced enclosure Advantages The enclosure is made of molded high density and reinforced fiberglass material. Benefits The enclosure is extremely solid and resistant thus guaranteeing durable protection. The enclosure is also built to withstand elevated temperatures. Autonomous and automated operation Our system is the only electronic Remote and autonomous operation system for automated identification and management that can operate autonomously. helps to reduce overall operating and maintenance costs. Active LR (RFID) This system offers the possibility of Remote and secure data identification Secure and robust communication protocol remotely identifying data in an automated and secure fashion. and collection provides an independent and covert data flow. The RF environment is more and Data is transmitted using an encoding more saturated, hence the need for robust communication means. system that maintains a very high degree of data integrity. It is therefore possible to recover data even in extreme circumstances. Technical specifications General information Operational & Environmental Outside dimensions (Enclosure) Operating temp. :
-40 +85C Height :
Width :
Length :
44.45 mm (1.75 inches) 190.50 mm (7.50 inches) 127.00 mm (5.00 inches) Material :
Molded reinforced fiberglass Color :
Light-grey / Beige Antenna :
Rubber duck 1/4 Battery Type :
LisoC Primary (no maintenance) Chemistry :
Lithium Thyonil Chloride Charge time :
Non-Rechargeable Capacity-Voltage : 10Ah ~ 14.75Vdc Environmental protection :
IP6x (non-immersed) Specifications ( TX / RX ) Receiver Span (freq.) :
Modulation :
Sensitivity:
Transmitter Span (freq.) :
Modulation :
Encoding :
902.000MHz ~ 928.000MHz SSFH / 2FSK
-114 dBm 902.000MHz ~ 928.000MHz FH / 2FSK Variable encoding Output power :
30 dbm Electrical Supply voltage (lead in) :
N/A (Internal sealed bat pack) Internal voltage:
3.3Vdc Electrical consumption:
Variable. Peak 0.05%
Certifications Industry Canada FCC (United-States) RSS-247 Issue1 Part 15 (C) The information contained in this document may be changed or modified without notice. This information remains the sole and exclusive property of Otodata Wireless Network Inc.