A725 addSDI User Manual SMART WIRELESS SOLUTIONS ADC NO T E L E M E T R Y ADCON TELEMETRY GMBH I N K U S T R A S S E 2 4 A-3400 KLOSTERNEUBURG A A TEL: +43 | 2243 | 38280-0 FAX: +43 | 2243 | 38280-6 h t t p : / / w w w . a d c o n . a t h t t p : / / w w w . a d c o n . a t U R S T I LYNDELL ADCON INTERNATIONAL INC 2050 TERRACE S U I T E 1 2 0 C A - 9 5 6 1 6 D A V I S , U S A TEL: +1 | 530 | 753-1458 FAX: +1 | 530 | 753-1054 h t t p : / / w w w . a d c o n . a t h t t p : / / w w w . a d c o n . a t B O X ADCON AUSTRALIA PTY. LTD. ENFIELD PLAZA SA 5058 P O 6 0 5 A D E L A I D E A U S T R A L I A TEL: +61 | 8 | 8260-4682 FAX: +61 | 8 | 8260-4685 h t t p : / / w w w . a d c o n . a t h t t p : / / w w w . a d c o n . a t Proprietary Notice:
The Adcon logo, addSDI, addIT, addWAVE, addVANTAGE, addVANTAGE Profes-
sional and AgroExpert are trademarks or registered trademarks of Adcon Telemetry. All other registered names used throughout this publication are trademarks of their respective own-
ers. Neither the whole nor any part of the information contained in this publication may be repro-
duced in any material form except with the prior written permission of Adcon Telemetry. This publication is intended only to assist the reader in the use of the product. Adcon Telemetry shall not be liable for any loss or damage arising from the use of any information in this publica-
tion, or any error or omission in such information, or any incorrect use of the product. Document Release 1.0, Dezember 2006 Copyright '2003-2006 by Adcon Telemetry. CHAPTER 1 About the A725 addSDI___________________________________________________3 Conventions _____________________________________________________________4 Opening the packages ____________________________________________________5 Installing the RTU ________________________________________________________6 Field Installation_______________________________________________________7 More about the LED tool _______________________________________________8 Configuring an addSDI RTU in the addVANTAGE software__________________9 Maintaining and servicing the RTU__________________________________________9 The RTU battery_______________________________________________________9 Changing the battery ________________________________________________ 10 Understanding connectors_______________________________________________ 14 The POWER Connector ______________________________________________ 14 The SDI Connector __________________________________________________ 15 SDI-12 Sensor Connections ______________________________________________ 16 Self powered Sensor _________________________________________________ 17 Multiple Sensors connected to the SDI-12 Bus __________________________ 18 Communicating with the RTU ____________________________________________ 18 Serial communication protocol ___________________________________________ 19 General format of a command ________________________________________ 19 General format of an answer __________________________________________ 20 Using terminal commands _______________________________________________ 20 Returned errors list _____________________________________________________ 37 Command line interpreter ____________________________________________ 37 Device descriptors and storage handler ________________________________ 37 Real time clock ______________________________________________________ 37 Radio interface ______________________________________________________ 37 Specifications _________________________________________________________ 39 2 CHAPTER CHAPTER 1 About the A725 addSDI 3 Chapter 1. Introduction This manual explains the hardware aspects of Adcons A725 addSDI Remote Telemetry Units, including installation issues and certain parameter configurations. The manual is divided as follows:
"Introduction," which contains some general information and document conventions.
"Using the A725 RTU," which details the installation and use of the Remote Telemetry Unit.
"Specifications," which describes operating parameters for the devices. About the A725 addSDI The A725 Remote Telemetry UnitRTU (commercial trademark addSDI) is a low power, short range telemetry device, capable of operating SDI-12 compatible sensors. The frequency of operation is in the 432 to 470 MHz range, mak-
ing it compliant to most radio communication regulations in the world. The output power is under 10 mW, while the modulation is narrow band FM (12.5 or 25 kHz channel spacing). Due to its construction, as well as to the software controlling it, the power consumption is extremely low. The unit operates from a built in 6.2 Volt rechargeable battery, which is charged either using a solar panel or an external power supply adapter. A special con-
figuration may be implemented where no internal battery is used, but the power is obtained exclusively over an external connector. The SDI-12 bus is also powered by the internal 6.2 Volt battery, therefore the attached SDI-12 sensors must be able to work within 4 CHAPTER 1 Introduction Conventions a minimum voltage of 5.6V. This is lower than the official SDI-12 minimum operating voltage. The A725 is a ruggedized unit, complying with the IP65 environ-
mental protection class (NEMA 4). It can easily be installed and it integrates perfectly into an Adcon A733 network. Depending on the terrain, it assures a reliable wireless connection to an A733 series device to distances up to 1000 meters, under favorable con-
ditions even more. Certain conventions apply in this document. Italics Bold fixed font FileSave Note Indicate that the text is variable and must be substi-
tuted for something specific, as indicated in the expla-
nation. Italics can also be used to emphasize words as words or letters as letters. Indicates special emphasis of the text. Also indicates menu names and items in a window. Indicates characters you must type or system mes-
sages. Indicates menu selection. For example, select the File menu, then the Save option. Indicates information of interest. Notes appear after the information they apply to.
CAUTION Indicates that you may get unexpected results if you dont follow the instructions. Cautions appear before the information they apply to.
WARNING Indicates danger to yourself or damage to the device if you dont follow the instructions. Warnings appear before the information they apply to. 5 Chapter 2. Using the addSDI The A725 addSDI Remote Telemetry Unit (RTU) is part of the A7xx series. For testing purposes, you should have an A840 Telemetry Gateway installed before you install the A725 RTU. For informa-
tion about installing the A840, refer to the Base Station, Telemetry Gateway A840 and Wireless Modem A440 User Guide. Opening the packages The addSDI RTU package contains the A725 RTU, an antenna, and a pipe clamp. If ordered, the following items come in separate packaging:
A solar panel and pipe clamp A set of aluminum poles A LED tool Sensors and cables, one box for each sensor. Make sure you have received all the equipment and read through the instructions that follow. Once you are sure to understand them, you are ready to install your RTU. 6 CHAPTER 2 Using the addSDI Figure 1 shows the front view of an addSDI RTU. Gore PreventTM SDI-12 Connector To Solar Panel
WARNING Do not turn or manipulate the Gore Prevent element!
The units IP65 environmental protection may be affected. Figure 1. addSDI RTU Installing the RTU The following restrictions apply:
In general the typical line-of sight distance over which the RTU can communicate is 1 km (.6 miles). This is valid if both the RTU and its partner device are mounted on a 3 m mast (9 ft.); the results may vary under different conditions, and you can sometimes achieve greater distances, sometimes shorter. CHAPTER 2 Installing the RTU 7 Field Installation
As with all wireless communication devices, the higher the transmitter is installed, the better the communication will be. Installing addSDI RTUs in the field is a fairly simple process. You can perform a connectivity check with a LED tool. The LED tool is shown in Figure 2. Figure 2. LED Tool Note: The LED tool is a blind plug to be connected to the POWER connector. Follow these steps to install an addSDI RTU in the field:
1. 2. Review the installation area and choose the best site. Perform a connectivity check using the LED tool:
a. Insert the LED tool into the POWER connector and wait up to 10 seconds. If the unit connects to at least one station (or a base station), it will light up the LED for about 4 seconds. Keep observing the LED tool and, after another several seconds, the LED will blink one or more times (the number of blinks indicates the number of stations it has contacted). b. 3. Assemble the mast from the set of poles. 4. Drive the tipped aluminum pole vertically into the ground, using a sledge hammer. Put the pole pounder cap on top of the pole to protect it from damage while hammering it in. How far you drive the pole into the ground depends on your application and the soil. Sandy soils in windy areas might require guy wires to secure the pole. 5. Using a pipe clamp, fasten the solar panel onto the aluminum mast. Make sure that the panel is facing south (north if you are located in the southern hemisphere) and is out of the way of the addSDI RTU. 8 CHAPTER 2 Using the addSDI
Note: The solar panel can be mounted under or behind the addSDI RTU, but be sure that the RTU does not shadow the panel. 6. Fasten the addSDI RTU to the top of the mast using another pipe clamp. Adcon recommends that you perform another connectivity test, if you can, to check the positioning of the device. WARNING If you turn the fastening screws too tight, you might damage the plugs. 7. Attach the SDI-12 sensor to the SDI jack and the solar panel to the POWER jack by turning the connectors fastening screws clockwise until secured tightly. Secure access cable of the SDI-12 cable to the pole with cable ties. To protect it from damage dont let it sit on the ground!
8. This completes the installation of your addSDI RTU. If the SDI-12 jack is left unused, use the attached cap, meant to protect it against moisture and dust. Be sure to make a note of the following information because youll need it when you configure the device in the software:
WARNING The SDI-12 sensor addresses must be set prior to attaching the sensors to the SDI-12 bus. Be sure to use unique addresses only! There is no way to resolve address conflicts once the sensors are attached to the SDI-12 bus. Serial number of each RTU Type and address of SDI-12 sensors connected to each RTU More about the LED tool The LED tool allows you to rapidly check the status of an addSDI RTU. After you insert the LED tool into the POWER connector, the unit waits for up to two seconds and then sends a broadcast frame. If a nearby station or receiver decodes the frame, it will answer this may take up to 10 seconds. When an answer is received, the LED tool lights up for about 4 seconds. A few seconds later, the LED will light up again one or several times - once per station/
receiver that answered to its broadcast frame. After that the LED continuously blinks briefly in 0.5 second inter-
vals to indicate that the unit is alive and that the internal battery has enough energy to operate. If the blinking interval lengthens to 2 seconds, the battery has become undercharged (that is, under CHAPTER 2 Maintaining and servicing the RTU 9 5.6 volts but over 5.2 volts)this is called the misery state. In this state, an addSDI RTU reduces its activities to a minimum. The radio unit is switched off, the sensor sampling ceases, and no data is stored in the internal memory. Only the internal real-time clock is maintained and the power management functions are performed. If the battery level drops below 5.2 volts, the system switches off completely, effectively decoupling itself from the battery in order to protect it. In this case the LED tool stays permanently off. An addSDI RTU in such a situation will restart only after connecting it to an external power supply (even a solar panel under low light conditions). Note: New addSDI RTUs are delivered with their internal batteries unformatted, meaning they are completely discharged, and you should install them only on sunny days. The battery will be fully charged after two consecutive sunny days, but you should get an LED light-up after several minutes of charging in the sunlight. Configuring an addSDI RTU in the addVANTAGE software To configure the addSDI RTU with an A840 Telemetry Gateway and the addVANTAGE Pro software, check the Base Station, Telemetry Gateway A840 and Wireless Modem A440 User Guide. Maintaining and servicing the RTU The A725 unit needs virtually no maintenance. It is waterproof and designed to withstand harsh environmental conditions (-30 to
+70 C, or -22 to 158 F), high RH values, water, and other noncor-
rosive liquids. It conforms to the European protection class IP65. This applies also to the connectors, as long as they are mated. Dont let unmated connectors on either the addSDI RTU or the sensors be exposed to the environment for extended periods of time. The internal NiMH rechargeable battery pack supplies 6.2 volts. The internal electronics manage the battery charging/discharging process, ensuring it a long life. This approach, coupled with a remarkably low average consumption, allows an addSDI RTU to The RTU battery 10 CHAPTER 2 Using the addSDI operate at least two weeks on a fully charged battery under the fol-
lowing conditions:
The channel has moderate radio activity, with requests every 15 minutes. Sensor readings are stored in the internal memory every 15 minutes. The sensors do not drain excessive current (neither in sleep-
mode nor during measurement).
Table 1 shows the addSDI devices expected operating time on a fully charged battery under various conditions.. Table 1. addSDI Device Operation Time Radio Activity Average SDI-12 Sensor Current Average Consumption
(mA) No Yes Yes none none 1.1mA 0.667 0.833 1.8 Estimated Operation
(days) 100 80 37 Note: Radio activity means that one base station and between one and three RTUs are active on the same operating frequency as the addSDI remote station under test. However, if for some reason (wear-out or accident) the battery loses its capacity (noted in the software with repeated Battery low messages), it must be replaced. Make sure, though, that the problem is really due to the battery and not to a defective or dirty solar panel. Adcon highly recommends you to take good care of your solar panels! Clean them frequently with a damp cloth. Rain droplets might splash thin layers of soil onto the panels, wind and spraying covers them with dust, birds tend to drop things onto them, thus reducing their power output. Watch out for the surrounding vege-
tation! A solar panel, well exposed to the sun at the beginning of the season, might be shadowed by growing vegetation as the sea-
son progresses. CHAPTER 2 Maintaining and servicing the RTU 11 Changing the battery If you have verified that the battery needs to be replaced, follow these steps to do so:
1. Open the lid by unscrewing the four screws in the corners of the addSDI RTU, then remove the lid as shown in Figure 3. Figure 3. Removing the addSDI Lid 2. The battery pack is connected to the electronics board by means of a PCB connector. Remove the battery packs plug from the PCB connector, as shown in Figure 4. Figure 4. Unplugging the PCB Connector 12 CHAPTER 2 Using the addSDI 3. Unscrew the two screws of the metal cover that holds the battery pack in place, then remove the cover. Figure 5 shows the A725 battery pack inside the RTU. Figure 5. A725 Battery Pack 4. 5. 6. Remove the battery pack and replace it with a new one
(obtainable from your Adcon dealer). Put the metal cover back in place and secure it with the two screws. Replace the old cover seal with the new one, provided together with your battery, as rubber gaskets tend to stiffen and might not reseal properly. Place the rounded side of the gasket into the groove and have the flat side showing!
Insert the battery plug into the PCB connector. 7. 8. Mount the lid back, taking care that the rubber gasket sealing the box is not out of place.
WARNING Be sure to mount the rubber gasket properly, so that the units IP65 environmental protection is not affected. Dont clamp the battery cable between the lid and the case, as this might damage the cable and shorten the unit. Watch for soil and dust on the seal, as this might lead to water ingress!
13 Chapter 3. Performing Advanced Functions
With the appropriate knowledge you can configure the addSDI devices in the field by using a hyperterminal window. To configure the RTU you need a special serial adapter cable (item 200.720.540;
not included with the RTU; available from your Adcon distributor). CAUTION Do not try to configure your addSDI devices if you are not well familiar with the SDI-12 commands and bus architecture
the unit may not communicate properly with the SDI-12 sensors and/or with the remote measuring station or function with the addVANTAGE software. WARNING Tampering with parameters for the addSDI devices may void your warranty or damage the device. In general, the commands described in this chapter are intended for technical support staff and users with a great deal of experience in handling advanced hard- and software. In the system architecture, the base station and RTU are both con-
sidered to be nodes. The base station is called the master node, or master, while the RTU is called the slave node, or slave. 14 CHAPTER 3 Performing Advanced Functions Understanding connectors The addSDI devices have cable attachments called connectors. The connector type determines how the device communicates with the sensors or the computer. The POWER Connector The RTUs POWER connector, a 5-pin M9 jack, allows for:
External charge supply (either a solar panel or an AC adapter) if the internal rechargeable battery is used. (as in most cases). External power supply (battery or any DC source from 5.6 to 10 volts), with the internal battery removed Communication over a serial connection with 19200 baud
Figure 6 illustrates the connections available at the POWER con-
nector. Ext Power Battery 5 4 1 2 3 Ground RxD TxD
Figure 6. A725 POWER Connector (Top View) WARNING The serial line is 3-volt CMOS compatible; therefore, the above mentioned adapter cable must be used to reach the RS-
232 levels (Adcon item number 200.720.540). You might want to use the POWER connector with something other than the standard configuration. For example, if you want to connect an external battery to the RTU, disconnect the internal battery and use the configuration shown in Figure 7. Battery
(5.6 to 10 Volt)
5 4 1 2 3 Short Figure 7. A725 Wiring up an External Battery CHAPTER 3 Understanding connectors 15 If you want to use the internal battery with a different power sup-
ply (charger) than the ones provided by Adcon (120 or 300mA solar panels or the ACS110 charger), make sure to use the wiring as shown in Figure 8. 5 4 1 2 3 Short Charger
(9 to 10 Volt, 100 to 300 mA)
Figure 8. A725 Connection with External Power Supply And if you want to use an external battery, charged by its own solar panel, you need to disconnect the internal the internal bat-
tery and the Adcon solar panel and use the wiring as shown in Figure 9.
Charger
(must fit the Battery)
Battery
(5.6 to 10 Volt)
5 4 1 2 3 Short Figure 9. A725 Connection with External Battery and Power Supply The SDI connector is used to connect the addSWITCH A725 to an SDI-12 Sensor bus (See Figure 10). The connector used is a female 5 pin SWITCHCRAFT jack (EN3P5F, the counterpart is the EN3C5M). The A725 comes with a 1m cable with flying ends. A standard cable clamp can be used to connect the sensors. It is up to the user to protect this cable clamp for outdoor usage. Please contact your local Adcon dealer for special SDI-12 wiring boxes. The SDI Connector 16 CHAPTER 3 Performing Advanced Functions
GND SDISense 1 2 3 5 4 SDIGND gray SDIDATA yellow SDIPOWER green Figure 10. The SDI-12 Connector If you do not use an SDI-12 sensor with the proper cable already mounted, but will connect it to the SDI bus through a wiring box, it is absolutely crucial to obey the following instructions: first identify the function of each of the sensors cables. Then connect them to the wiring box in exactly the folloing order: First connect SDI-GND. Then connect SDI-POWER (only if a sensor receives its power sup-
ply from the RTU) and last connect SDI-DATA. Else you might cause the SDI-12 bus to perform unexpectedly!
CAUTION Some SDI-12 sensors have a rather high startup current, which prevents operation with our low power addSDI RTU. Always check your SDI-12 sensors peak current draw upon start-up! This is of particular importance when connecting more than one sensor to the SDI-12 bus - while one sensor might still operate flawlessly with your RTU, two might draw too much current and cause the RTU to shut off the bus. This will occurr when the total power draw on the SDI-12 bus goes beyond 500mA. In case of doubt or questions please consult your sensor supplier or your Adcon dealer. Note: Please see also SDI-12 spec for additional wiring and setup information. To enable the SDI-12 bus operation, a jumper must be installed between GND (Pin 1) and SDI-Sense (Pin 2). This jumper is factory installed in the connector of the standard 1m cable, which comes with your addSDI RTU. Note: When the SDI-12 bus is not used, please disconnect the SDI connector and the solar panel from your addSDI. The RTU will then switch to a power save mode. CHAPTER 3 SDI-12 Sensor Connections 17 SDI-12 Sensor Connections Sensor powered by RTU To connect a single SDI-12 sensor, that does not have its own power supply, follow the wiring scheme as shown in Figure 11. GND SDIGND Detection Jumper SDISense 1 2 3 5 4 SDIDATA SDIPOWER gray yellow green SDIGND SDIDATA POWER SDI12 SENSOR Figure 11. Single Sensor Connection, sensor is powered by the RTU Note: In this configuration, the RTU powers the SDI-12 sensor. The sensor must be capable of working with a supply voltage as low as 5.6V. WARNING Check the minimum supply voltage of your sensor BEFORE installing it! This information should be available from your sensor supplier.
Self powered Sensor Sensors with an integrated power supply must be connected fol-
lowing the wiring scheme in Figure 12. 18 CHAPTER 3 Performing Advanced Functions GND SDIGND Detection Jumper SDISense 1 2 3 5 4 SDIDATA SDIPOWER green gray yellow SDIGND SDIDATA SDI12 SENSOR self powered Figure 12. Single Sensor Connection, for sensor with internal battery pack Multiple Sensors connected to the SDI-12 bus
Multiple sensors can be connected to the SDI-12 bus as long as the following conditions are met:
the maximum total (!) current consumption (500mA) is not exceeded the maximum number of sensor values (20) is not exceeded all sensors have unique addresses
WARNING If two sensors with identical addresses are connected to the same bus, communication with these sensors is not possible. Note: The factory default address of most SDI-12 sensors is usually 0. Please use an appropriate tool, usually delivered by the sensor manufacturer, to change the address. The A725 addSDI RTU is not capable of changing addresses of SDI-12 sensors. The sensors can be connected in a star, daisy chain or mixed topol-
ogy. Self powered and RTU powered sensors can also be mixed. See Figure 13 for details. CHAPTER 3 Communicating with the RTU 19 GND SDIGND Detection Jumper SDISense 1 2 3 5 4 SDIDATA SDIPOWER gray yellow green s e l f p o w e r e d I S D 1 2 S E N S O R I S D D A T A I S D G N D P O W E R I S D D A T A I S D G N D I S D 1 2 S E N S O R Communicating with the RTU Figure 13. Multiple SDI-12 sensors
WARNING Please disconnect the SDI connector, when attempting to configure the A725 RTU via the A720SC serial cable. You will not be able to communicate with your A725 addSDI RTU as long as the SDI connector is plugged in. You can use a Windows Hyperterminal window to connect to the addSDI RTU. After you have installed the system, follow these steps to configure the device and set the default parameters:
Note: To configure the A725 RTU you must use the A720SC adapter cable mentioned above (available from your Adcon dealer) and connect it to the POWER jack of the RTU. 1. Open a Hyperterminal window. 2. 3. Configure your terminal as follows:
Select the appropriate serial port and click OK.
19200 baud 1 stop bit 8 data bits No parity No protocol (neither hardware nor software) 20 CHAPTER 3 Performing Advanced Functions 4. 5. Select OK to open the terminal window. Press Enter to generate a response in the window. Serial communication protocol This protocol is based on a master sending commands and a node answering. The whole communication is conducted in plain ASCII strings. When exchanging numbers, they are represented in deci-
mal format. All commands are terminated with a CR/LF combina-
tion. All responses (answers) are terminated with the # character. General format of a command The commands have the following format:
ID Command Param1 Param2 ... ParamN
ID is the destination device. If you include an ID as part of a command, the node checks whether ID=ownID. If it does, the node executes the command on itself. If the ID is not the nodes ID, the node executes the command on a remote device, if such an ID exists. Not naming any ID implies that the command is addressed locally. Note: Not all the commands can be executed remotely!
Command is the command proper, which can be composed of a variable string of characters (for example, SLOT). Each node can implement a set of commands depending on the functionality of the node itself. However, as a minimum requirement, a node recognizes the CMDS command, which returns a list with the commands accepted by the node. Param1 Param2 ... ParamN represent the parameters, which are command dependent. If you type no parameters when you issue a command, it is the equivalent of querying for information (the GET version of a command). If you type parameters, you are issuing the SET version of a command and are setting the command to the parameters you typed.
General format of an answer The answers have the following format:
ID Command Result1 Result2 ... ResultN ErrResult #
CHAPTER 3 Using terminal commands 21
ID is the answering device. If a command was further routed, it is the ID of the end device. The answer must always contain the ID on return. Command is the string representing the original command. It is supplied so that a master can distinguish between the answers it is waiting for, and out-of-band notifications (which may come, for example, over the radio port of a node). As with the ID, the command name must always be supplied. Result1 Result2 ... ResultN are the result values returned by the remote node. If the ErrResult is not zero, all other possible characters and/or strings until the end of the line may be ignored. ErrResult shows whether the command was successfully executed or not. If this value is 0, the command was successfully executed. If this value is other than 0, the command failed. The number may further indicate the error type. (See also Returned errors list on page 37.) The answer string may contain any number of spaces or CR/LF characters between its components; however, after the terminator
(#) no other characters are allowed. Using terminal commands The A725 addSDI firmware is basically the same as used with the A723 addIT, except for the following items:
new device type: A725 only SDI-12 Sensors available The following list describes all available commands and their usage. Note: You can type uppercase or lowercase characters because the commands are not case sensitive. CMDS DESCRIPTION PARAMETERS RETURNS REMARKS Returns a list of supported commands. None. A list of strings separated by spaces. GET only. 22 CHAPTER 3 Performing Advanced Functions REMOTE EXAMPLE TIME DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE FREQ
DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE No. CMDS 15535 CMDS CMDS ID PMP RSSI TIME FREQ SLOT DATA INFO RX TX FDEV 0
Sets/returns the real time clock. The actual time, or none in the GET version. The actual time as dd/mm/yyyy hh:mm:ss. GET/SET. No. TIME 12/12/1999 22:10:10 15535 TIME 0
TIME 15535 TIME 12/12/1998 22:10:10 0
CAUTION Do not change the frequency of your device without reason: apart from the fact that it might not communicate in the network anymore, you might also violate the applicable radiocommunications laws in your country. Depending on the destination country, some models may also return an error message. Sets/returns the operating frequency. The operating frequency and step (Hz), or none in the GET version. The actual frequency and step, in Hz. GET/SET. Yes, SET only. FREQ 433925000 25000 15535 FREQ 0
CHAPTER 3 Using terminal commands 23 FREQ 15535 FREQ 433925000 25000 0
Sets/returns the Relative Signal Strength Indicator threshold at which the RF receiver must wake up. The threshold value. For the A725, it can take values from 0 to 255; it is typically factory set to 42. The instant RSSI value and the programmed threshold. GET/SET. No. RSSI 50 15535 RSSI 0
RSSI 15535 RSSI 34 50 0
Note: The values of the RSSI threshold have no units, they are arbi-
trary. However, a value of 160 corresponds approximately to the maximum value allowed in the addVANTAGE software
(that is, 8 V). Sets/returns the nodes ID. The node ID. The node ID. GET/SET. Yes, SET only. ID 4557 15535 ID 0
RSSI DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE ID DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE 24 CHAPTER 3 Performing Advanced Functions ID 4557 ID 4557 0
SLOT
DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE PMP DESCRIPTION PARAMETERS RETURNS CAUTION Changing these parameters may adversely affect the ability of the device to operate for extended periods under low sun shine conditions. Sets/returns the nodes sampling interval and rate. The interval (60 - 65535) and rate (0 - 255). The interval represents the time (in seconds) elapsed between two slots stored in the inter-
nal memory, while the rate represents the numbers of samples used to build the average that will be stored. Note: The rate parameter is not relevant for the A725 RTU. The sensors firmware is responsible for calculations of avaraged values etc. The interval and rate. GET/SET. The default interval is 900 (15 minutes) and rate is 15 (15 samples per 15 minutes). Yes, SET only. SLOT 900 15 15535 SLOT 0
SLOT 15535 SLOT 900 15 0
Sets/returns the nodes Power Management Parameters (switches the battery charge on/off). The lower (switch on) and the higher limit (switch off), both in volts x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for 7.2 Volts) for switch off (for a standard 6.2 Volt NiCd or NiMH bat-
tery). From these values, other thresholds are internally computed. The lower (switch on) and the higher limit (switch off), both in volts x 10. REMARKS REMOTE EXAMPLE DATA DESCRIPTION PARAMETER RETURNS REMARKS REMOTE EXAMPLE CHAPTER 3 Using terminal commands 25 GET/SET. Yes, SET only. PMP 65 72 15535 PMP 0
PMP 15535 PMP 65 72 0
Returns data stored for a certain device. Note: This command cannot be used to retrieve data from the SDI-12 subsystem. Please see the description of the SDI-
DATA command therefore. The ID of the device for which the data is requested and the date/
time (in the standard format) the data was stored. If missing, then it refers to the data of the local device. A data block. Note: The addSDI does not support analog sensors. GET only. If the date/time parameter is not included, the latest data is returned. If the date/time parameter is included, the data closest to, but later than, the given date/time is returned. Yes, for a GET, but only one frame at a time. The A725 can issue the command only for itself, locally. DATA 15535 1/3/2000 12:12:12 15535 DATA b1 b2 b3 ... bn 0
The data block returned will typically contain a number of data frames (telegrams). The structure of a block is as follows:
dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy ... dn cs where:
dd mm yyyy is the date hh mm ss is the time 26 CHAPTER 3 Performing Advanced Functions
si is the size of the frame ft is the frame type (39 for the A725) d1 d2 ... dn are the data values (the frame content) cs is a 16-bit checksum obtained by summing the bytes and discarding the carries over 0xFFFF The A725 devices always responds with a type 39 data frame. The composition of the data block of such a frame (the values marked as d1, d2... dn) is depicted in Figure 14, while the digibyte is depicted in Figure 15. RF incoming RF outgoing Digibyte Pulse Counter CNT0, always 0 Pulse Counter CNT1, always 0 Battery I/O A Cabling 1, always 0 I/O A Cabling 2, always 0 I/O A Cabling 3, always 0 I/O B Cabling 1, always 0 I/O B Cabling 2, aways 0 I/O B Cabling 3, always 0 Checksum Figure 14. Frame 39 description b7 SC Res Res Res Res Res Res b0 Res SC Solar Cell (0off, 1on) Figure 15. The Digibyte The remote version is limited to a single frame. An example of such a command is given below:
9999 DATA 9999 13/12/2006 19:46:00 9999 DATA 13 12 2006 19 46 23 13 39 255 255 3 0 0 89 0 0 0 0 0 0 0 0 0 0 0 0 2258 0
CHAPTER 3 Using terminal commands 27 Notice that if you need to get data that is not the last (newest) slot remotely from a device, the ID must be supplied twice. If you need to get the last slot stored, you can ignore the ID and the date/time parameters:
9999 DATA 9999 DATA 13 12 2006 22 15 00 13 39 255 255 3 0 0 87 0 0 0 0 0 0 0 0 0 0 0 0 3311 0
Samples all inputs and immediately returns the sampled data. Note: This command cannot be used to get data values from the SDI-12 subsystem. The ID of the requested subsystem; default is the standard A/D subsystem of the A725 (ID=0). A data block (see also DATA on page 25). Note: The analog inputs are disabled on the A725. GET only. The command needs a certain delay to execute (for example, for the standard subsystem this delay amounts to two seconds. The delay is necessary to allow for the sensors to settle after applying power to them. No. IMME 4711 imme 13 12 2006 20 00 18 13 39 0 0 127 0 0 84 0 0 0 0 0 0 2209 0
Formats the internal memory (destroys all the data). If the parameters are missing, the command will destroy all the data in the EEPROM file. If a parameter is given, the EEPROM type is defined (data wont be destroyed). The following EEPROM types are currently defined:
IMME DESCRIPTION PARAMETER RETURNS REMARKS REMOTE EXAMPLE FDEV DESCRIPTION PARAMETER 28 CHAPTER 3 Performing Advanced Functions RETURNS REMARKS REMOTE EXAMPLE INFO DESCRIPTION PARAMETER RETURNS
0 16 Kbytes (e.g. model 25128) 1 32 Kbytes (e.g. model 25256) Nothing. SET only. Yes, SET only. FDEV 1 15535 FDEV 0
Returns various status information. None. A list of a devices internal variables:
ID INFO rf_in rf_out date time ver clk stack cop batt temp days_uptime hr:min_uptime rssi pmp_low pmp_high type slot sam-
ples po err_level
The formats for the above parameters are as follows:
rf_in and rf_out as a decimal date as dd/mm/yyyy time as hh:mm:ss ver as x.x clk, stack, and cop as decimal; they represent internal housekeeping parameters: the A725 uses cop to number watchdog occurrences, but clk and stack are currently undefined batt as battery level using the standard voltage conversion equation (0 is 0 volts, 255 is 20 volts) temp as internal temperature in the A725 housing, which is device dependent. The precision of the sensing element is low (2C), but it is sufficient for battery power management
CHAPTER 3 Using terminal commands 29
(charge/discharge). To compute the actual value (in C), the following equation must be used:
Temp C[
internalTemp 400
255 68 days_uptime in days; together with hr:min_uptime, it represents the amount of time the device is up without a reset or watchdog hr:min_uptime in hours:minutes format rssi as decimal; it is the value programmed with the RSSI command pmp_low and pmp_high are the programmed values with the PMP command ) type is used to represent the device type; the following types are currently assigned:
0 for A730MD
1 for A720
2 for A730SD
3 for A720B
4 for A733
5 for A723
6 for A440
7 for A733GSM
8 for A731
9 for A732
10 for A740
11 for A740GSM
12 for A724
13 for A725
14 for A726 slot and samples are the actual values programmed by means of the SLOT command po is the power output of the device during the last frame sent err_level is the error value; 0 means no error
REMARKS REMOTE GET only. Yes, GET only. The A725 can issue the command both remotely and locally.
30 CHAPTER 3 Performing Advanced Functions EXAMPLE RX DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE TX DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE INFO 15535 INFO 0 84 13/12/2006 20:02:29 2.10 2 0 0 85 59 0 3:52 42 65 72 12 60 1 0
Switches the unit to permanent receive mode (for tuning pur-
poses). None. Nothing. The system stops, and exits the command only when a key is pressed. This command returns no message. No. RX 15535 RX 0
Switches the unit to transmit mode (for tuning purposes). None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated carrier), 0 (sends a 2 kHz modulated carrier) or 5 (sends a mixed 1
+ 2 kHz modulated carrier). Nothing. The system stops, and exits the command only when a key is pressed. This command returns no message. No. TX 15535 TX 0
TX 1 15535 TX 0
B DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE BLST DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE CHAPTER 3 Using terminal commands 31 TX 5 15535 TX 0
Sends a broadcast frame. None. A data block. After the device has sent the broadcast frame, it will listen for answers. All valid answers will be listed with their IDs. Yes. A device getting this frame would have to wait for a random time (2 to 10 seconds) before performing the actual broadcast; if no terminal is active, then no results will be listed. A list of heard stations with their RF levels will be updated in the memory and will be available whenever the BLST command is issued. B 15535 B 0
#234 BA 0
#7851 BA 0 Lists the stations heard after the last broadcast command was issued. None. The date and time when the broadcast was performed, the num-
ber of stations heard, and a list with the heard stations ID and their respective RF levels. GET only. Yes. The remote version will list only the first 9 stations heard. BLST 15535 BLST 10/12/1999 12:15:04 4 2008 150 2003 177 6883 168 4027 220
32 CHAPTER 3 Performing Advanced Functions VER DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE SDI DESCRIPTION PARAMETERS Requests the firmware version of the device. None. The current version. GET only. No. VER 15535 VER 2.14.0 0
A complex command that can be used to check the status of the SDI-12 subsystem, as well as configure it. The command has a multitude of options. If issued without param-
eters, the GET variant is implied, i.e. the status of the SDI-12 sub-
system will be returned (see also bellow). The following parameters/formats of the command can be used:
sdi + adds a measurement to the list. If you add the C argument, CRC-measurements are used (default is without CRC). You can set a different measurement method with M followed by a number (default M0) or you can choose continuous measurement by choosing R followed by a number. In addition, you can set up to 24 bits in the value index map by adding a mix of several index numbers
(separated by white spaces or ',', default 0-19) and bit masks starting with 0x, e.g., 0x3 for indexes 0 and 1 (see also the examples). The R-Method performs Continuous Measurements (see SDI-12 standard). All measurements are performed sequentially in the order they are situated in the table. sdi - removes a configuration entry. The argument are the sdi-
addr and the method ('M' or 'R') and optionally the checksum flag 'C'. Sensors are considered as belonging to the same sensor unit if they have the same sdi-addr and method. sdi I returns the sensor configuration, including the sensor identifier string in double quotes, where \ and " in the id string are escaped with a \. Invalid characters (those outside
CHAPTER 3 Using terminal commands 33
the SDI-12 allowable characters 0..31, 127..255) are substituted with an underscore (_). The arguments are the same as in sdi - command. sdi ! resets the SDI-12 configuration. All previous entries are deleted from the configuration table. sdi * forces a sensor discovery cycle after the next measurement cycle. The status of the operation can be checked by issuing an sdi command without arguments (the GET version). All sensors discovered will be displayed in the list. When the discovery operation ends, D flag changes back to d (see also below).
CAUTION Use the sdi ! and sdi * command with absolute precaution, because the RTUs SDI-12 configuration may be deleted!
RETURNS The following information is supplied in the form of a string of characters in the case the command was issued without arguments
(the GET variant):
a/A The presence of the SDI-12 BUS: a absent, A active;
w/W Wait-State of the system: w not waiting, W waiting for an SDI-12 sensor;
m/M Measurement command status: m no measurement is being done, M a measurement is in progress;
v/V Availability of Values for storage: v no values are available, V values are available for local storage;
d/D discovery initiation: d no discovery pending, D discovery pending (will be done at the next sensor poll cycle). In addition, for every programmed SDI-12 sensor, the following information will be listed:
method + CRC the measuring method, either M (normal) sensor id the sensor ID in ASCII (0 - 9, A - Z and a - z);
or R (continuous), optionally followed by the CRC flag (C);
index the indices used (in hexadecimal), e.g.: 0x3 if indices 0 and 1 are used.
Note: For further information about the significance of the above terms please also consult the specification of the SDI-12 standard, version 1.3 (http://www.sdi-12.org). 34 CHAPTER 3 Performing Advanced Functions REMARKS REMOTE EXAMPLE SET/GET. Yes. Initiate a discoverycommand
#sdi *
#sdi 35385 sdi awmvD 0 0 Discovery is pending (D). Detach A720SC Serial Cable and attach SDI-12 bus and wait for at least 1 minute; the bus will be scanned. Detach the SDI-12 bus, wait 2s and attach A720SC again. Proceed with the following command:
#sdi 35385 sdi awmvd 1 0 M0 0xfffff 0
The answer indicates: 1 sensor found at address 0, method 0 and index mask is 0xfffff (all 20 indices, 0-19). Note: Every 1 in the index mask (binary), corresponds to a selected index, e.g. 0x3 corresponds to index 0 and 1. Example for three equivalent configuration commands:
sdi + 0 M0 3,4,5,9 sdi + 0 M0 0x238 sdi + 0 M0 0x230,3 DATASDI DESCRIPTION PARAMETERS The binary representation of 0x238 is: 1000111000b (bits 3,4,5 and 9 are set). Returns a slot of SDI-12 sensor data, if any. Offset and date/time, both optional. If an offset is specified, then only the values after the offset are returned, all others are skipped. RETURNS CHAPTER 3 Using terminal commands 35 The date/time specifies the first slot to be retrieved that is strictly
younger than the specified time stamp. The data block returned will typically contain a number of data frames. The structure of a block is as follows:
dd mm yyyy hh mm ss si ft rfin rfout db batt sdih sdib1 sdib2 ... sdibn cs where:
dd mm yyyy is the date hh mm ss is the time si is the size of the frame (variable for the SDI frames) ft is the frame type (60) rfin is the RFin RSSI value rfout is the RFout RSSI value db is the digibyte value batt is the battery voltage value sdih ist the SDI-12 header sdib1, sdib2 ... sdibn are the SDI-12 sensor quadruples cs is a 16-bit checksum obtained by summing the bytes and discarding the carries over 0xFFFF (float values are not included in the checksum). The composition of the data block of such a frame (the values marked as sdih, sdib1... sdibn) is depicted in Figure 16. 36 CHAPTER 3 Performing Advanced Functions SDI count SDI offset SDI available SDI address SDI method SDI index SDI value (floating point) SDI address SDI method SDI index SDI value (floating point) SDI address SDI method SDI index SDI value (floating point) SDI value #1 SDI value #2... SDI value #n Figure 16. SDI-12 Data Frame, part of type 60 Frame The frame is similar to the standard DATA frame, but has the SDI sensor values appended after the battery value. The frame type 60 contains SDI-12 data only.
SDI-12 specific parameters are explained below:
SDI count represents the number of configured SDI values following in the SDI data block. SDI offset the offset in the SDI-12 frame. Usually it is 0 (no offset is used). SDI available is the number of SDI-12 sensor values effectively returned. The difference between the SDI count and SDI available indicates missing sensors (down or damaged). Usually these two values are identical. SDI values this is a number of SDI-12 quadruples:
SDI address SDI method SDI index SDI value (floating point). See also the example below . Note: The remote version is limited to a single frame. REMARKS GET only. CHAPTER 3 Returned errors list 37 REMOTE EXAMPLE Yes.
#12800 datasdi SDA DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE 12800 datasdi 16 5 2003 20 14 49 44 60 255 255 127 87 9 0 9 3 0 0 74.379401 3 0 1 68.117003 3 0 2 58.832397 3 0 3 51.611795 3 0 4 38.346400 3 0 5 19.800799 3 0 6 14.895999 3 0 7 3.553500 3 0 8 0.037200 2953 0
Sets/returns the maximum delay for waiting awake (i.e. out of sleep mode) for a service request of an SDI-12 sensor. This param-
eter is set to 30 seconds by default. A larger value may lead to higher power consumption. This should be used in cases an SDI-
12 sensor needs large time values to return a sensor result. If you have such sensors and still want to use them, you need to change this parameter, but please be aware of the fact that the RTUs power consumption will be higher. Maximum wake time in seconds (1 to 999). The current value (in seconds). SET/GET. No SDA 35385 SDA 30 0
#SDA 50 35385 SDA 0
Returned errors list In the following section you find the error messages you might get. 38 CHAPTER 3 Performing Advanced Functions Command line interpreter
1 command not recognized (=it doesnt exist or isnt supported) 2 command line buffer overflow (input line too long) 3 internal error 4 reserved 5 missing or false parameters in command 6 operation not implemented 7 remote operation not allowed 8 Invalid IMEI checksum number Device descriptors and storage handler
10 device not found (attempt to perform a command on a non-existent device) 11 device already exists 12 reserved 13 no more space for descriptors (too many devices) 14 no more records for the specified device 15 temporary communication break, no more data (the last request was not successful) 16 time-out (the handler blocked or is busy) 17 internal error 18 attempt to insert a reserved device ID number (0 or 65535) 20 incorrect time supplied (conversion to time_t was not possible) 30 error at receive (CRC, etc.) 31 unexpected frame received 32 wrong length 33 reserved 34 reserved 35 time-out (remote device not responding) Real time clock Radio interface CHAPTER 3 Returned errors list 39
36 receiver busy (for example, just executing a polling series) 37 time stamp of a frame is too far in the future 38 general modem error 39 Appendix. Specifications The A725 addSWITCH was built to match the specification of the ETSI 300 220, Class I, Subclasses a and b, but other national norms are similar to this (for example, the CFR 47, Part 90, Subpart J). Table 2 shows the main operational parameters of the A725. Table 2. Operational Parameters Parameter Min Typ Max Unit Common Supply Operating Temperature Relative Humidity Class Protection Data Rate (using the onboard software modem) Operating Frequency b Frequency Stability (-20 to +60 C) Frequency Stability (-30 to +70 C) Receiver 6.2 IP65 1500a 5.0
-30 10 1000 432 10.0
+70 99 2000 470 1.5 2.5 V
C
bps MHz kHz kHz 40 Table 2. Operational Parameters (Continued) Parameter Min Typ Max Unit
-105 Sensitivity (10 db S/N) Image Frequency Attenuation (1st IF = 45 MHz) Local Oscillator Leakage Adjacent Channel Attenuation RSSI Dynamic Operating Current (incl. onboard microcontroller)c 35 55 90 Transmitter (all measurements made on a 50 Ohm resistive load) Output Power Spurious Radiation (0 to 862 MHz) Spurious Radiation (862 MHz to 3.5 GHz) Adjacent Channel Power (12.5 kHz version) Adjacent Channel Power (25 kHz version) Occupied Bandwidth (12.5 kHz version) Occupied Bandwidth (25 kHz version) Operating Current (incl. onboard microcontroller) SDI-12 Sensor Supply Voltaged Sensor Supply Currente 7 9 5.5 6.0 dBm dB nW dB dB mA dBm nW nW dBm dBm kHz kHz mA V mA 2 20 10 2 200
-32
-44 8.5 15 50 10.0 500 a. Data rate is content dependent. b. This parameter represents the tuning range; the switching range may be limited in the software to a narrower space (even to the extent of a single channel). c. Continuous duty. d. This applies for sensors which are powered by the RTUs internal battery. e. This is the maximum peak current for all sensors on the SDI-12 bus.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-02-01 | 450 ~ 470 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-02-01
|
||||
1 | Applicant's complete, legal business name |
Ott Hydromet GmbH Business Unit Adcon Telemetry
|
||||
1 | FCC Registration Number (FRN) |
0011471562
|
||||
1 | Physical Address |
Inkustr. 24
|
||||
1 |
Klosterneuburg, N/A A-3400
|
|||||
1 |
Austria
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
m******@tuev.or.at
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
SHX
|
||||
1 | Equipment Product Code |
A725
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G******** C********
|
||||
1 | Telephone Number |
+43-2******** Extension:
|
||||
1 | Fax Number |
+43-2********
|
||||
1 |
g******@ott.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Adcon Telemetry GmbH
|
||||
1 | Name |
G**** C******
|
||||
1 | Physical Address |
Inkustr. 24
|
||||
1 |
Klosterneuburg, A-3400
|
|||||
1 |
Austria
|
|||||
1 | Telephone Number |
+4322******** Extension:
|
||||
1 | Fax Number |
+4322********
|
||||
1 |
g******@adcon.at
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Telemetry transceiver | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV Austria (Oesterreich)
|
||||
1 | Name |
H******** E********
|
||||
1 | Telephone Number |
43-1-********
|
||||
1 | Fax Number |
43-1-********
|
||||
1 |
s******@tuev.or.at
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 90.217(b) | 450.00000000 | 470.00000000 | 0.0100000 | 1.5000000000 ppm | 8K50F1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC