A73x addWAVE User Guide valid for A731, A732, A733 and A733GSM RTUs Release 2.0 and higher Rel. 2.1 / September 2004 U ADCON TELEMETRY GmbH I N K U S T R A S S E 2 4 A-3400 KLOSTERNEUBURG A A TEL: +43-2243-38280-0 FAX: +43-2243-38280-6 h t t p : / / w w w . a d c o n . a t R S T I Proprietary Notice:
The Adcon logo, the A720 series and addIT, the A730 series and addWAVE, addVANTAGE and AgroExpert are trademarks or registered trademarks of Adcon Telemetry GmbH. All other registered names used throughout this publication are trademarks of their respective owners. This publication contains confidential information, property of Adcon Telemetry GmbH. Disclosure to third parties of the information contained herein is prohibited. Neither the whole nor any part of the information contained in this publication may be reproduced in any material form except with the prior written permission of Adcon Telemetry GmbH. Release 2.1, September 2004 Copyright 2004 by Adcon Telemetry GmbH. All rights reserved. Table of Contents Table of Contents 1 1.1 1.2 1.3 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.7.1 2.7.2 3 3.1 3.1.1 3.1.2 3.2 3.3 3.3.1 3.3.2 3.4 Introduction .........................................................................5 About the addWAVE A73x...............................................................5 Compliance Statement and Warnings .............................................6 Conventions .....................................................................................7 Using the A73x RTU ............................................................9 Opening the packages .....................................................................9 Installing the RTU...........................................................................10 Special notes for the A733GSM RTU ............................................11 Field Installation .............................................................................13 More about the LED tool ................................................................14 Configuring an A73x RTU in the addVANTAGE software..........................................................................................15 Maintaining and servicing the RTU................................................15 The RTU battery.............................................................................15 Changing the battery......................................................................16 Performing Advanced Functions.....................................19 Understanding connectors .............................................................19 The RTU connectors......................................................................19 The POWER Connector.................................................................20 Communicating with the RTU ........................................................21 Serial communication protocol.......................................................22 General format of a command .......................................................22 General format of an answer .........................................................22 Using terminal commands .............................................................23 CMDS.............................................................................................23 TIME...............................................................................................23 3 FREQ .............................................................................................23 RSSI...............................................................................................24 ID....................................................................................................24 SLOT..............................................................................................25 SST ................................................................................................25 PMP ...............................................................................................25 ANLG .............................................................................................26 DATA..............................................................................................29 IMME..............................................................................................31 FDEV..............................................................................................31 INFO...............................................................................................32 PORT .............................................................................................33 RX ..................................................................................................36 TX...................................................................................................36 B.....................................................................................................37 BLST ..............................................................................................37 VER................................................................................................38 SDI .................................................................................................38 DATASDI........................................................................................39 SDA................................................................................................41 FPC ................................................................................................41 GSMPIN .........................................................................................42 GSMPUK........................................................................................42 GSMSTAT......................................................................................42 Notifications....................................................................................43 Returned errors list ........................................................................43 Command line interpreter ..............................................................44 Device descriptors and storage handler ........................................44 Real time clock...............................................................................44 Radio interface...............................................................................44 Notifications....................................................................................45 Specifications....................................................................47 Index...................................................................................51 Table of Contents 3.5 3.6 3.6.1 3.6.2 3.6.3 3.6.4 3.6.5 4 5 4 1 Introduction Introduction This manual explains the hardware aspects of Adcons A733, A732, A731 and A733GSM remote telemetry units (further referred to as A73x), including installation issues and certain parameter configurations. The manual is divided as follows:
"Introduction", which gives some general information and document conventions.
"Using the A73x RTU", which details the installation and use of the remote telemetry unit.
"Performing Advanced Functions", which contains technical information for the advanced user.
"Specifications", which describes operating parameters for the devices. 1.1 About the A73x RTU family The A73x family of Remote Telemetry Unit (RTU) consists of four types of low power, telemetry devices, namely the A733, A732, A731 and the A733GSM (EU and US). The following table gives an overview of the capabilities of these devices. Type Analog inputs Digital Inputs Outputs SDI-12 0 6 12 12 0 4 (2 counters) 8 (4 counters) 8 (4 counters) A731 A732 A733 A733GSM Both A733 are capable of sampling up to 12 analog and 8 digital inputs (of which 4 counter types); in addition, it can control up to 4 outputs. A 3 volt CMOS serial interface is also built-in, allowing for configuration, data download, or expansion
(e.g. various bus implementations). Latest firmware (starting with version 2.0) No Yes Yes Yes 0 2 4 4 Serial Interface Yes Yes Yes Yes 5 Compliance Statement and Warnings supports the SDI-12 bus implementation. The unit is based on a powerful 8 bit Flash RISC microcontroller, that can also be field programmed (software upgraded). The only difference between these devices and the A732 and A731 is the number of analog and digital interfaces. The A731, A732 and A733 RTUs incorporate an A431 radio module operating in the 430 to 470 MHz range, making it adaptable to most radio communication regulations in the world. The output power is variable up to 0.5 W, while the modulation is narrow-band FM (6.25, 12.5 or 25 kHz channel spacing). The A733GSM RTU incorporates a GSM module and uses the standard GSM network for retrieving telemetry data (900/1800MHz in Europe, 1900MHz in the US). Due to its construction, as well as to the software controlling it, the power consumption is extremely low (on average 1 mA without sensors, approx. 3 mA for the GSM version). The RTUs operate from a built-in NiCd 6.2 Volt rechargeable battery, which is charged using either a solar panel or an external power adapter. A special configuration may be implemented where no internal battery is used, rather the power is obtained exclusively over an external connector. The A73x is a rugged RTU, complying with the IP65 ingress protection class
(NEMA 4). Depending on topography it ensures a reliable wireless connection to other A73x RTUs, an A730MD or A730SD device or an A840 Telemetry Gateway over a distance of up to 20 km (12 miles). The A733GSM has no such limitations, however, your cellular service provider must cover the site where you want to install the RTU. The A733GSM operates in conjunction with the A840 Telemetry Gateway only. 1.2 Compliance Statement and Warnings The A73x must not be used with any antenna other than the one supplied by Adcon (or an antenna with identical technical specifications). A minimum distance of 18cm to the antenna is required in order to guarantee compliance with basic safety restrictions. In conformity with the EC Parliament recommendations 1999/519/EG 28V/m is the reference value for the frequency range used. By adhering to any and all recommended reference levels, the compliance to basic restrictions serving the protection of the general public against electromagnetic fields is ensured. This device is notified in the following countries:
Australia, Austria, Germany, Denmark, Finland, France, Greece, Hungary, Italy, Ireland, Netherlands, Norway, Poland, Portugal, Spain, Sweden, Switzerland, United Kingdom, USA In some countries individual user licences and frequency allocations need to be applied for. Please consult your dealer for further information. The above paragraphs are not applicable to the A733GSM RTU. The A733GSM is available for the European 900MHz and 1800MHz networks as well as for the 1900MHz infrastructure in the US and several other countries. Using the equipment in 850MHz networks is not authorized. Note:
6 Introduction This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
1. this device may not cause harmful interference, 2. this device must accept any interference received, including interference that may cause undesired operation, 3. any manipulations on this device other than mentioned in this manual void the FCC type approval. 1.3 Conventions Certain conventions apply in this documentation. Italics Bold fixed font FileSave Note
CAUTION
WARNING Indicate that the text is variable and must be substituted for something specific, as indicated in the explanation. Italics can also be used to emphasize words as words or letters as letters Indicates special emphasis of the text. Also indicates menu names and items in a window. Indicates characters you must type or system messages. Indicates menu selection. For example, select the File menu, then the Save option. Indicates information of interest. Notes appear after the information they apply to. Indicates that you may get unexpected results if you dont follow the instructions. Cautions appear before the information they apply to. Indicates danger to yourself or damage to the device if you dont follow the instructions. Warnings appear before the information they apply to. 7 Using the A73x RTU 2 Using the A73x RTU The A73x series of remote telemetry units (RTU) is part of the A730 series. For testing purposes, you should have an A730SD/A730MD and/or an A840 Telemetry Gateway installed before you install your A73x RTU. For information about installing the A730SD or A730MD, refer to the addVANTAGE A730 User Guide Version 3.4x. For information about installing the A840, refer to the Base Station, A840 Telemetry Gateway and Wireless Modem A440 User Guide. The A733GSM RTUs operates in conjunction with an A840 Telemetry Gateway only. 2.1 Opening the packages The A73x RTU package contains the A73x RTU, an antenna, and a pipe clamp. If ordered, the following items come in separate packaging:
A solar panel with pipe clamp A set of aluminum poles A LED tool Sensors and cables, one box for each sensor, and fastening ties in each sensor box Make sure you have received all the equipment and read through the instructions that follow. When you are sure you understand them, you are ready to install your RTU. Fig. 1 and Fig. 2 show the top and bottom view of an A733 addWAVE RTU. 9 Installing the RTU Fig. 1:
addWAVE RTU (top) Fig. 2:
addWAVE RTU (bottom) 2.2 Installing the RTU The following restrictions apply:
In general, the typical line-of sight distance the RTU can communicate is 10 km (6 miles). This is valid if both the RTU and its partner device are mounted on a 3 m mast (9 ft.); the results may vary under different conditions, and you can sometimes achieve greater distances. The above does not apply for the A733GSM RTU. In principle there is no distance limit for this type of devices as long as your cellular provider covers the area where it is installed. As with all wireless communication devices, the higher the transmitter is, the better the communication will be. All A73x devices accept the standard Adcon sensors (A731 excluded), which are different from the A730MD series, in that they provide IP65 class protection. All Adcon sensors are delivered by default with type of connector. An adapter cable is optionally available to connect current sensors to the RJ-12 ports of the A730MD stations. For technical reasons, Adcon cannot provide adapters for the RJ-12 connector to the A73x devices. Note:
Note:
10 Using the A73x RTU 2.3 Special notes for the A733GSM RTU The A733GSM RTU is based on a GSM module which employs a GSM cellular network to transmit the telemetry data. Before you install such a device you must make sure that there is sufficient signal for proper operation of the RTU on the site you plan to use it; this is done best by using a standard cellular phone operated by the same cellular provider. You can also check if you can communicate with the RTU simply by calling it as a normal cellular phone. Most cellular/GSM providers use a different telephone number for data communication than for voice communication. Dont forget to ask for it when you order your SIM card!
When you call the RTU from a standard phone, use the data number: else the RTU will answer, but immediately send a busy tone, as the voice call cannot connect to a data terminal. In addition you need to insert your SIM card into the SIM-holder inside your A733GSM RTU. This is done as follows:
1. Open the lid of the A733GSM RTU by unscrewing the four bolts in the corners of the RTU, then remove the lid as shown in Figure 3 . Fig. 3:
Removing the A73x Lid Note:
It is not required to remove the battery plug from the base board during this operation, but make sure nothing is attached to the POWER connector!
Fig. 4:
Installing the SIM card in the A733GSM RTU 2. Locate the SIM card holder and open it by sliding it as indicated by the red arrow (see Fig. 4, left). 11 Special notes for the A733GSM RTU 3. Raise the holder top and slide the SIM card into it (Fig. 4, center). 4. Snap the holder top back on and slide it back as shown again by the red arrow depicted in Fig. 4, right. 5. Mount the lid back, taking care that the rubber gasket sealing the box is not out of place and free of dust or dirt. Be sure to mount the rubber gasket properly, so that the units IP65 environmental protection is not affected. 6. Screw the four screws back in, applying a moderate force, tightening crosswise. This completes the SIM-card installation. Now you will need to activate the card by means of a PIN code. You will find this code in the package that you got from your cellular service provider. In order to be able to activate your card, the A733GSM must be properly powered. As the RTUs are delivered from the factory with the batteries uncharged (they have a longer shelf life in this state) you will need to charge the batteries first. The best way to do this is to attach the solar panel to the power connector and expose the RTU to the sunlight for at least one hour. If the sky is overcast the battery will still charge, but at a lower rate; in this case allow for at least four hours or more of charge. To enter the PIN code you will also need a serial adapter cable; this can be obtained from Adcon Telemetry or your reseller. Proceed as follows:
1. Connect the serial cable between the COM port of your PC and the RTU. Configure your terminal as follows: 19200 baud, 1 stop bit, 8 data bits, no parity, no handshaking protocol (neither hardware nor software). For more details on this issue you may want also to check the section Communicating with the RTU on page 21. 2. Make sure that you can communicate with the RTU by pressing the enter key:
the device will answer with its own ID number and a hash sign (#). 3. Now type the command GSMPIN nnnn (where nnnn is the PIN code) and press enter; if the PIN was correct, the RTU will answer id gsmpin 0, where id is its ID number. This completes the PIN entry procedure. You can check the status of the A733GSM RTU by typing at any time the command GSMSTAT. This command returns a list of GSM parameters:
#gsmstat 26142 gsmstat GSM modem on: Yes SIM card found: Yes PIN set: Yes PIN accepted: Yes Sleepmode OK: Yes PUK required: No Default IMEI nr: No Attempts left to enter PIN: 3, PUK: 10 0
The above shows that
WARNING:
12 Using the A73x RTU the GSM modem is on there is a valid SIM card inserted the SIM card was activated with a valid PIN code. Additional information is also listed but this should be of no concern for the user, except the PUK required entry. If this parameter is Yes, it can be the result of entering a wrong PIN code three times in a row. You can see this also in the last string displayed by the GSMSTAT command (number of retries left). To re-activate the card you will need its PUK number, which you get also from your cellular provider with the SIM-card. To reactivate the card, enter the command GSMPUK pppppppp nnnn (where pppppppp is the PUK code and nnnn is the new pin code). Note that the new pin code will immediately be used and will activate the SIM card. Your A733GSM RTU has an internationally unique identification number (IMEI). You will find this number on a leaflet packaged with your device, and it is needed in case of loss of the device. Please keep it in a safe place.
WARNING:
2.4 Field Installation Installing A73x RTUs in the field is a fairly simple process. Youll perform a connectivity check with an LED tool (does not apply to A733GSM RTUs). The LED tool is shown in Fig. 5. Note:
Note:
Fig. 5:
LED Tool The LED tool is a blind plug to be plugged into the POWER connector. Follow these steps to install an A73x RTU in the field:
1. Review the installation area and choose the best site (for the A733GSM RTU skip to Step 2.3). 2. Perform a connectivity check using the LED tool:
a. Insert the LED tool in the POWER connector and wait up to 10 seconds. If the unit connects to at least one station (or a base station), it will light up the LED for about 4 seconds. b. Keep observing the LED tool and, after several more seconds, the LED will blink one or more times (the number of blinks indicates the number of stations it has successfully contacted). For the A733GSM, make sure that you have sufficient RF signal from your cellular service provider. The simplest way to achieve this is to check a cellular phone operated by the same cellular service provider on the site where you want to install the RTU. 3. Assemble your pole set. 13 More about the LED tool Note:
WARNING:
4. Using a hammer, drive the 80cm aluminum rod into the ground. Prior to that put an Adcon plastic cap into the top of the pole and secure it with a pie clamp in order to protect the top of the pole from damage. 5. Using the pipe clamp supplied fasten the solar panel onto the pole. Make sure that the panel is facing south (north if you are located in the southern hemisphere) and out of the way of the A73x RTU. The solar panel can be mounted under or behind the A73x RTU, but make sure that the RTU does not shadow the panel. 6. Fasten the A73x RTU to the top of the pole with a pipe clamp. Adcon recommends that you perform another connectivity test (not for the A733GSM), if you can, to check the positioning of the device. If you turn the fastening screws too tightly, you could damage the connectors:
7. Attach the sensors to the I/O connectors and the solar panel to the POWER connector by turning the plugs fastening screws clockwise until secure. If you have SDI-12 sensors, attach the SDI-12 adapter and the respective sensors. For more details on how to install the SDI-12 adapter, consult the leaflet that came with the adapter. 8. 9. Secure the extra length of the sensor cables to the pole with cable ties. This completes the installation of your A73x RTU. If one of the I/O connectors is left unused, use the cap specially provided to protect it against moisture and dust. Be sure to make a note of the following information because youll need it when you configure the device in the software:
Serial number for each RTU (for the A733GSM RTUs also the data telephone number) Type of sensors connected to each RTU and to which I/O port. 2.5 More about the LED tool The LED tool allows you to rapidly check the status of an A73x RTU. After you insert the LED tool into the POWER connector, the unit waits up to two seconds and then sends a broadcast frame (does not apply to the A733GSM RTU). If a nearby listening station or receiver decodes the frame, it will answer backthis may take up to 10 seconds. When an answer is received, the LED tool lights up for about 4 seconds. After another few seconds, the LED lights up one or more times, depending on the number of stations/receivers that answered to its broadcast frame. In addition, the LED always blinks briefly at 0.5 second intervals to indicate that the unit is alive and the internal battery has enough energy to operate. If the blinking interval lengthens to 2 seconds, the battery has become undercharged (that is, under 5.6 volts but over 5.2 volts)this is called the misery state. In this state, an A73x RTU reduces its activities to a minimum. The radio unit is switched off, the sensor sampling ceases, and no data is stored in the internal memory. Only the internal real-time clock is maintained and the power management functions are performed. If the battery level drops below 5.2 volts, the system switches completely off, effectively decoupling itself from the battery in order to protect it. In this case the LED tool stays permanently off. An A73x RTU in such a situation will restart only after connecting it to an external power supply (even a solar panel under low light conditions). 14 Note:
Using the A73x RTU New A73x RTUs are delivered with their internal batteries unformatted, meaning they are completely discharged, and you should install them only on sunny days. The battery will be fully charged after two consecutive sunny days, but you should get an LED light-up after several minutes of charging in the sunlight. 2.6 Configuring an A73x RTU in the addVANTAGE software Note:
To configure the A73x RTU with an A730 base station system, follow the steps described in the addVANTAGE A730 User Guide Version 3.40. To configure the A73x RTU with an A840 Telemetry Gateway and the addVANTAGE 4 Pro software, check the Base Station, Telemetry Gateway A840 and Wireless Mode A440 User Guide. The addWAVE A733GSM RTU is not supported by the A730SD base station and addVANTAGE 3.x.; partial support to addVANTAGE 3.x is offered only if used in conjunction with the A840 Telemetry Gateway. For more details on this issue please consult your dealer. In addition, the SDI-12 adapter and sensors are not supported on the A730SD Base Station and the addVANTAGE 3.x software. 2.7 Maintaining and servicing the RTU The A733 unit needs virtually no maintenance. It is waterproof and designed to withstand harsh environmental conditions (-30 to +70 C, or -22 to 158 F), high RH values, water, and other non-corrosive liquids. It conforms to the European protection class IP65. This applies also to the connectors, as long as they are mated or capped. Dont let unmated/uncapped connectors on either the A73x RTU or the sensors be exposed to the environment for extended periods of time. When used in coastal areas with high salt content in the air the use of an extra protective case is recommended to avoid corrosion. Avoid spraying agrochemicals on your RTU, as they might form very aggressive compounds. 2.7.1 The RTU battery The internal battery supplies 6.2 volts and consists of a NiCd pack. The internal electronics manage the battery charging/discharging process, ensuring it a long life. This approach, coupled with a remarkably low average consumption (some mere 6 mW for the standard RTU and 15 mW for the GSM RTU), allows an A73x RTU to operate at least two weeks on a fully charged battery, with the following conditions:
The channel has moderate radio activity, with requests every 15 minutes. Total consumption of attached sensors is 100 mA. The sensors are sampled once every minute and an averaged slot is stored in the internal memory every 15 minutes. The following table shows the A73x devices expected operation time on a fully charged battery under various conditions. The sensor consumption totals 100 mA. 15 Maintaining and servicing the RTU Radio Activity No Low Heavy Low Low Heavy Sensor Sampling
(samples/15 min) No sensors No sensors No sensors 3 15 15 Average Consumption (mA) 0.85 2.8 5 4.2 6.3 9 Estimated Operation (days) 132 40 22 26 17 12 Table 1:
A73x Device Operation Time Note:
Low radio activity means that one base station and between one and three A730MDs/A73xs or A730SDs are active on the same operating frequency as the A73x remote station under test. Heavy radio activity means that approximately 30 devices are on the same channel. However, no routing is used. The table above does not apply to the A733GSM RTU. However, if for some reason (wear-out or accident) the battery loses its capacity
(noted in the software with repeated Battery low messages), it must be replaced. Make sure, though, that the problem is really due to the battery and not to a defective or dirty solar panel. Adcon highly recommends that you check the solar panels state and clean them often. The rain droplets can splash thin layers of soil on the panels, thus reducing their power output. The surrounding vegetation can also lower the panels efficiency. 2.7.2 Changing the battery If you have verified that the battery needs to be replaced, follow these steps to do so:
1. Open the lid by unscrewing the four screws in the corners of the A73x RTU, then remove the lid as shown in Fig. 6. Fig. 6:
Removing the A73x Lid 2. The battery pack is connected to the electronics board by means of a PCB connector. Remove the battery packs plug from the PCB connector, as shown in Fig. 7. 16 Using the A73x RTU Fig. 7:
Unplugging the PCB Connector 3. Unscrew the four screws of the plastic cover that holds the battery pack in place, then remove the cover. Fig. 8 shows the A733 battery pack inside the RTU. Fig. 8:
A733 Battery Pack 4. Remove the battery pack and replace it with a new one (obtainable from Adcon). 5. Replace the plastic cover and screw the four screws back in. 6. Carefully remove the rubber gasket in the lid and replace it with the one supplied with the battery. Insert the battery plug into the PCB connector. 7. 8. Mount the lid back, taking care that the rubber gasket sealing the box is properly seated.
WARNING:
Be sure to mount the rubber gasket properly, so that the units IP65 environmental protection is not affected. 9. Screw the four screws back in, applying a moderate force. 17 Maintaining and servicing the RTU 18 Performing Advanced Functions 3 Performing Advanced Functions With the appropriate knowledge, you can configure the A73x devices in the field by using a HyperTerminal window. To configure the RTU, you will need a special serial cable adapter (not supplied, available from Adcon). Do not try to configure your A73x devices if you are not sure what to dothe unit may not communicate with the remote measuring station or function with the addVANTAGE software. Tampering with parameters for the A73x devices may void your warranty or damage the device. In general, the commands described in this chapter are intended for technical support staff and users with a great deal of highly technical hardware and software experience. In the system architecture, the base station and RTU are both considered to be nodes. The base station is called the master node, or master, while the RTU is called the slave node, or slave. 3.1 Understanding connectors The A73x devices have cable attachments called connectors. The connector type determines how the device communicates with the sensors or the computer. 3.1.1 The RTU connectors The A73x RTU uses standard 7-pin sensor for all available I/O ports (A731 addRELAY excluded), model Binder 702 and 712 series or equivalent, that are identical. Each connector contains three analog inputs (0 to 2.5 volt) and two digital input/outputs, one of which you can use as a pulse counter (for example, a rain gauge). Fig. 9 illustrates the individual pins of an I/O connector. 19 Understanding connectors Switched Battery Digital I/O Pulse Counter 7 1 6 2 345 Ground Cabling 1 Cabling 2 Cabling 3 Fig. 9:
Pins on an I/O Connector (Top View)
CAUTION:
Using Adcons 7-pin Y-cable lets you attach more than one sensor to one connector. To avoid cabling conflicts, first verify in the addVANTAGE software that the sensor combination in the configuration you want is allowed. If there are no conflicts, you can physically attach the sensors to the A73x RTU. 3.1.2 The POWER Connector The A73x RTU also has a POWER connector, which allows for:
External supply (battery or any DC source from 5.6 to 10 volts) External charge supply (either a solar panel or an AC adapter) if an internal rechargeable battery is used Communication over serial lines, at 19200 baud Fig. 10 illustrates the connections available at the POWER connector. Ext. Power Battery 5 1 234 Ground RxD TxD Fig. 10:
A73x POWER Connector (Top View)
WARNING:
The serial line is 3-volt CMOS compatible; therefore, a special adapter cable must be used to reach the RS-232 levels. Also, if an external battery is used, the internal battery must be disconnected. You might want to use the POWER connector with something other than the standard configuration. For example, if you want to connect an external battery to the RTU, disconnect the internal battery and use the configuration shown in Fig. 11. 20 Performing Advanced Functions
Battery (5,6 to 10V)
5 1 234 Short Fig. 11:
A73x Connection with External Battery If you want to use the internal battery with a different power supply (charger) than the provided solar panel, disconnect the solar panel and use the configuration shown in Fig. 12.
Charger (9 to 10V, 100 to 300mA)
5 1 234 Short Fig. 12:
A73x Connection with External Power Supply And if you want to use an external battery with a different power supply (charger) than the provided solar panel, disconnect the internal battery and solar panel and use the configuration shown in Fig. 13.
Charger (must fit the battery)
Battery
(5,6 to 10V) 5 1 234 Short Fig. 13:
A73x Connection with External Battery and Power Supply 3.2 Communicating with the RTU Note:
You can use a Windows HyperTerminal window to connect to the A73x RTU. After you have installed the system, follow these steps to configure the device and set the default parameters:
To configure the A73x RTU, you must have a special adapter cable (available from Adcon) and plug it into the POWER connector. 1. Start a HyperTerminal session. 2. Select the appropriate serial port and click OK. 3. Configure your terminal as follows:
19200 baud 1 stop bit - 8 data bits No parity No protocol (neither hardware nor software) 4. Select OK to open the terminal window. 5. Press Enter to generate a response in the window. 21 Serial communication protocol 3.3 Serial communication protocol This protocol is based on a master sending commands and a node answering; the whole communication is conducted in plain ASCII, as strings. When exchanging numbers, they are represented in decimal format. All commands are terminated with a CR/LF combination. All responses (answers) are terminated with the #
character. 3.3.1 General format of a command The commands have the following format:
ID Command Param1 Param2 ... ParamN ID is the destination device. If you include an ID as part of a command, the node checks whether ID=ownID. If it does, the node executes the command on itself. If the ID is not the nodes ID, the node executes the command on a remote device, if such an ID exists. If the ID is missing, this implies that the command is addressed locally. Note:
Not all the commands can be relayed remotely. Command is the command proper, which can be composed of a variable string of characters (for example, SLOT). Each node can implement a set of commands depending on the functionality of the node itself. However, as a minimum requirement, a node recognizes the CMDS command, which returns a list with the commands recognized by the node. Param1 Param2 ... ParamN represent the parameters, which are command dependent. If you type no parameters when you issue a command, it is the equivalent of querying for information (the GET version of a command). If you type parameters, you are issuing the SET version of a command and are setting the command to the parameters you typed. 3.3.2 General format of an answer The answers have the following format:
ID Command Result1 Result2 ... ResultN ErrResult #
ID is the answering device. If a command was further routed, it is the ID of the end device. The answer must always contain the ID on return. Command is the string representing the original command. It is supplied so that a master can distinguish between the answers it is waiting for, and out-
of-band notifications (which may come, for example, over the radio port of a node). As with the ID, the command name must be always supplied. Result1 Result2 ... ResultN are the result values returned by the remote node. If the ErrResult is not zero, all other possible characters and/or strings until the end of the line may be ignored. ErrResult shows whether the command was successfully executed. If this value is 0, the command was successfully executed. If this value is other than 0, the command failed. The number may further indicate the error type. (See also Returned errors list on page 43.) 22 Performing Advanced Functions The answer string may contain any number of spaces or CR/LF characters between its components; however, after the terminator (#) no other characters are allowed. 3.4 Using terminal commands Note:
Following is a list of available commands and an explanation of their use. You can type uppercase or lowercase characters because the commands are not case sensitive. CMDS AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE TIME AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE FREQ
CAUTION:
A731 A732 A733 A733GSM Returns a list of supported commands. None. A list of strings separated by spaces. GET only. No. CMDS 9193 CMDS CMDS ID PMP RSSI TIME FREQ SLOT DATA INFO RX TX FDEV 0
A731 A732 A733 A733GSM Sets/returns the real time clock. The actual time, or none in the GET version. The actual time as dd/mm/yyyy hh:mm:ss. GET/SET. No. TIME 12/12/1999 22:10:10 9193 TIME 0
TIME 9193 TIME 12/12/1998 22:10:10 0
Do not change the frequency of your device without reason: apart from the fact it may not communicate in the network anymore, you may also violate the applicable radio-communications laws in your country. Depending on the destination country, some models may also return an error message. AVAILABLE FOR A731 A732 A733 A733GSM 23 Using terminal commands DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE Sets/returns the operating frequency. The operating frequency and step (Hz), or none in the GET version. The actual frequency and step, in Hz. GET/SET. Not applicable to the A733GSM. Yes, SET only. FREQ 433925000 25000 9193 FREQ 0
FREQ 9193 FREQ 433925000 25000 0
RSSI AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE Note:
ID AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE 24 A731 A732 A733 A733GSM v Sets/returns the Relative Signal Strength Indicator threshold at which the RF receiver must wake up. The threshold value. For the A73x non-GSM RTU, it can take values from 0 to 255;
it is typically factory set to 42. The instant RSSI value and the programmed threshold. GET/SET. Not applicable to the A733GSM. No. RSSI 42 9193 RSSI 0
RSSI 9193 RSSI 34 42 0
The values of the RSSI threshold have no units, they are arbitrary. However, a value of 160 corresponds approximately to the maximum value allowed in the addVANTAGE software (that is, 8 V). A731 A732 A733 A733GSM Sets/returns the nodes ID. The node ID. The node ID. GET/SET. Yes, SET only. ID 4557 9193 ID 0
ID 4557 ID 4557 0
SLOT
CAUTION AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE SST AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE PMP AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS Performing Advanced Functions Changing these parameters may adversely affect the ability of the device to operate for extended periods under low solar radiation conditions. A731 A732 A733 A733GSM Sets/returns the nodes sampling interval and rate. The interval (60 - 65535) and rate (0 - 255). The interval represents the time (in seconds) elapsed between two slots stored in the internal memory, while the rate represents the numbers of samples used to build the average that will be stored. The interval and rate. GET/SET. The default interval is 900 (15 minutes) and rate is 15 (15 samples per quarter of an hour). Yes, SET only. SLOT 900 15 9193 SLOT 0
SLOT 9193 SLOT 900 15 0
A731 A732 A733 A733GSM Sets/returns the RTUs sensors settling time; this is the time that elapses between powering the sensors and sampling them. Default value is 2 seconds. The settling time in seconds. The current settling time. GET/SET. Yes, SET only. SST 3 9193 SST 0
SST 9193 SST 3 0
A731 A732 A733 A733GSM Sets/returns the nodes Power Management Parameters (switches on/off the battery charge). The lower (switch on) and the higher limit (switch off), both in volts x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for 7.2 Volts) for switch off (for a standard 6.2 Volt NiCd battery). From these values, other thresholds are internally computed. The lower (switch on) and the higher limit (switch off), both in volts x 10. GET/SET. 25 Using terminal commands REMOTE EXAMPLE Yes, SET only. PMP 65 72 9193 PMP 0
PMP 9193 PMP 65 72 0
ANLG AVAILABLE FOR DESCRIPTION PARAMETERS A731 A732 A733 A733GSM Sets/returns various parameters of the analog subsystem (for example, the sampling/averaging method used for individual data acquisition channels). A control byte specifying the command and the analog input channel number the command is acting on:
Command Code Channel Number Fig. 14:
The ANLG Control Byte Layout. Some commands may also require one or two additional 12-bit parameters representing threshold values. The Channel Number selects the analog channel that will be affected by the command. For the A733, only 0000 to 1011 are accepted (only 12 analog channels are available). The Command Code specifies the operation that will be applied to the selected channel. They are described in Table below. Description Code 0000 RSM Read Sampling Method. This command reads the current programmed sampling method for all analog input channels. 0001 SSMMI Set Sampling Method to Minimum. The specified analog channel will be instructed to store the lowest sampled value 0010 SSMMA Set Sampling Method to Maximum. The specified analog channel will be instructed to store the highest sampled value 0011 SSMS Set Sampling Method to Sum. The specified analog channel will be instructed to store the sum of all sampled values Parameters Returns None The channel num-
ber The current sampling methods and the result (OK or ERROR). See also the table that follows Result (OK or ERROR) The channel num-
ber Result (OK or ERROR) The channel num-
ber Result (OK or ERROR) 26 Performing Advanced Functions Code 0100 SSMAA Set Sampling Method Description to Arithmetic Average. The specified analog channel will be instructed to store the arithmetic average of all sampled values 0101 SSMCA Set Sampling Method to Circular Average. The specified analog channel will be instructed to store the circular average of all sampled values. 0110 SSMF Set Sampling Method to First. Only the first sampled value will be stored in each slot 0111 SSML Set Sampling Method to Last. Only the last sampled value will be stored in each slot Parameters The channel num-
ber Returns Result (OK or ERROR) The channel num-
ber Result (OK or ERROR) The channel num-
ber Result (OK or ERROR) The channel num-
ber Result (OK or ERROR) The channel num-
ber None 1000 RNS Read Notification Status1. If no notification was pending, this command should return an error. If one was pending, then the last valid timestamp is returned and the notification is cleared 1001 RPNNER Read the Pending Notifications and the Notification Enable Register. This command returns the 16-bit Pending Notifications and the Notification Enable Registers; the channel Number has no significance for this command 1010 DAN Disable Any Notification 1011 RNTTL Read Notification Type and Thresholds/Limits The channel num-
ber The channel num-
ber 1100 ENOPTR Enable Notify On Positive Threshold Reached The channel num-
ber and the threshold (16 bit value) 1 See also Notifications on page 43. Returns the time when the threshold was reached (in standard time format) and the result (OK or ERROR) Two 16-bit integers (first the NE and then the PN register) and the result (OK or ERROR) Result (OK or ERROR) One 8-bit char
(Notification Type), two 16-bit integers
(first the lower limit and then the higher limit) and the result (OK or ERROR). If only a threshold was set, then the second 16-bit integer is irrelevant Result (OK or ERROR) 27 Using terminal commands Code 1101 ENONTR Enable Notify On Negative Threshold Reached Description 1110 ENOL Enable Notify if Out of Limits 1111 ENIL Enable Notify if Inside the Limits. Returns Result (OK or ERROR) Result (OK or ERROR) Result (OK or ERROR) Parameters The channel num-
ber and the threshold (16 bit value) The channel num-
ber and the limit values (16 bit value), first the lower and then the higher limit. The channel num-
ber and the limit values (16 bit value), first the lower and then the higher limit Sampling methods are defined by three bits, as follows. Sampling method Binary value Reserved Minimum 000 001 Maximum Sum Average
(arithmetic) 010 011 100 Average (circular) 101 First sample 110 Last sample 111 Description Not defined If more than one sample per slot is performed, the lowest value will be stored If more than one sample per slot is performed, the highest value will be stored. The sum of all samples for a certain slot will be stored. If more than one sample per slot is performed, the arithmetic average of all samples will be stored If more than one sample per slot is performed, the average computed on a circle will be stored (i.e. on a 0 to 359 deg. circle, overflow occurs at the 359 deg value). If more than one sample per slot is performed, the first value will be stored. All other samples are discarded. If more than one sample per slot is performed, the last value will be stored. All other samples are discarded. Following notification types can be returned when issuing the RNTTL command:
Notification Type Notify On Positive Threshold. Notify On Negative Threshold. Notify if Out of Limits. Notify if Inside the Limits. Value 00 01 10 11 The return result depends on the control byte (see table). However, whatever the return result is, it includes the control byte. RETURNS 28 REMARKS REMOTE EXAMPLE Performing Advanced Functions The general behavior is that an ANLG command issued on a certain input channel will override any previous ANLG commands affecting that channel. The A733 cannot issue ANLG commands remotely, but can execute them. For RSM ANLG 0 9999 ANLG 0 5 5 5 5 5 5 5 5 4 4 5 5 0
For SSMAA (on channel 4) ANLG 68 9999 ANLG 68 0
For DAN (on channel 0) ANLG 160 9999 ANLG 160 0
For RNTTL (on channel 2) ANLG 178 9999 ANLG 178 340 3900 0
For ENOPTR (on channel 10) ANLG 202 1000 9999 ANLG 202 0
DATA AVAILABLE FOR DESCRIPTION PARAMETER RETURNS REMARKS REMOTE EXAMPLE A733 A732 A731 A733GSM Returns data stored for a certain device. The ID of the device for which the data is requested and the date/time (in the standard format) the data was stored. If missing, then it refers to the data of the local device. A data block. GET only. If the date/time parameter is not included, the latest data is returned. If the date/time parameter is included, the date and time closest to, but later than, the given date/time is returned. Yes, for a GET, but only one frame at a time. The A733 can issue the command only for itself, locally. DATA 9193 1/3/2000 12:12:12 9193 DATA b1 b2 b3 ... bn 0
The data block returned will typically contain a number of data frames (telegrams). The structure of a block is as follows:
29 Using terminal commands The data block returned will typically contain a number of data frames (telegrams). The structure of a block is as follows:
dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy ... dn cs where:
dd mm yyyy is the date hh mm ss is the time si is the size of the frame (21 for frame type 37, 13 for frame type 38) ft is the frame type (37 for the A733, 38 for A732 and A731) d1 d2 ... dn are the data values (the frame content) cs is a 16-bit checksum obtained by summing the bytes and discarding the carries over 0xFFFF The A733 devices always respond with a type 37 data frame. The A731 and A732 respond with a type 38. The composition of the data blocks of such frames (the values marked as d1, d2... dn) is depicted in Fig. 15 while the digibyte is depicted in Fig. 16. A733 A732 / A731 RF incoming RF outgoing Digibyte I/O A Pulse Counter I/O B Pulse Counter I/O C Pulse Counter I/O D Pulse Counter Battery I/O A Cabling 1 I/O A Cabling 2 I/O A Cabling 3 I/O B Cabling 1 I/O B Cabling 2 I/O B Cabling 3 I/O C Cabling 1 I/O C Cabling 2 I/O C Cabling 3 I/O D Cabling 1 I/O D Cabling 2 I/O D Cabling 3 RF incoming RF outgoing Digibyte I/O A Pulse Counter I/O B Pulse Counter Battery I/O A Cabling 1 I/O A Cabling 2 I/O A Cabling 3 I/O B Cabling 1 I/O B Cabling 2 I/O B Cabling 3 Fig. 15:
Frame 37 (left) and Frame 38 (right) description 30 Performing Advanced Functions b7 b0 SC Dig6 Dig5 Dig4 Dig3 Dig2 Dig1 Dig0 SC-Battery Charge (0-off, 1-on) Fig. 16:
Dig n Digital I/O n The Digibyte The remote version is limited to a single frame. An example of such a command is given below:
9999 DATA 9999 30/9/1999 14:50:00 9999 DATA 30 9 1999 14 54 55 21 37 255 255 77 0 0 0 0 89 156 126 20 0 0 0 0 0 0 0 0 0 3197 0
Notice that if you need to get data that is not the last (newest) slot remotely from a device, the ID must be supplied twice. If you need to get the last slot stored, you can ignore the ID and the date/time parameters:
9999 DATA 9999 DATA 13 9 1999 19 26 36 21 37 255 255 79 0 0 0 0 87 148 149 15 0 0 0 0 0 0 0 0 0 3148 0
IMME AVAILABLE FOR DESCRIPTION PARAMETER Note:
RETURNS REMARKS REMOTE EXAMPLE A731 A732 A733 A733GSM Samples all inputs and immediately returns the sampled data. The ID of the requested subsystem; default is the standard A/D subsystem of the A733 (ID=0). Currently only the default subsystem is implemented on the A73x. A data block (see also DATA on page 29). GET only. The command needs a certain delay to execute (for example, for the standard subsystem this delay amounts to two seconds. The delay is necessary to allow for the sensors to settle after applying power to them. No. IMME 15695 IMME 26 5 2003 17 18 28 21 37 0 0 127 0 554 0 0 84 0 0 0 1016 2048 3072 0 0 0 0 0 0 9056 0
FDEV AVAILABLE FOR DESCRIPTION A731 A732 A733 A733GSM Formats the internal memory (destroys all the data). 31 Using terminal commands PARAMETER If the parameters are missing, the command will destroy all the data in the EEPROM file. If a parameter is given, the EEPROM type is defined (data wont be destroyed). Following EEPROM types are currently defined:
0 16 Kbytes (e.g. model 25128) 1 32 Kbytes (e.g. model 25256) RETURNS REMARKS REMOTE EXAMPLE Nothing. SET only. Yes, SET only. FDEV 1 9193 FDEV 0
A731 A732 A733 A733GSM Returns various status information. None. A list of a devices internal variables:
ID INFO rf_in rf_out date time ver clk stack cop batt temp days_uptime hr:min_uptime rssi pmp_low pmp_high type slot samples po err_level
The formats for the above parameters are as follows:
rf_in and rf_out as a decimal (irrelevant for the A733GSM) date as dd/mm/yyyy time as hh:mm:ss ver as x.x clk, stack, and cop as decimal; they represent internal housekeeping parameters: the A733 uses cop to number watchdog occurrences, but clk and stack are currently undefined batt as battery level using the standard voltage conversion equation (0 is 0 volts, 255 is 20 volts) temp as internal temperature in the A733 housing, which is device dependent. The precision of the sensing element is low (2C), but it is sufficient for battery power management (charge/discharge). To compute the actual value (in C), the following equation must be used:
Temp =
internalTemp * 400 255
- 68 days_uptime in days; together with hr:min_uptime, it represents the amount of time the device is up without a reset or watchdog hr:min_uptime in hours:minutes format rssi as decimal; it is the programmed value with the RSSI command
(irrelevant for the A733GSM) INFO AVAILABLE FOR DESCRIPTION PARAMETER RETURNS 32 Performing Advanced Functions pmp_low and pmp_high are the programmed values with the PMP command (irrelevant for the A733GSM) type is used to represent the device type; following types are assigned currently:
0 for A730MD 1 for A720 2 for A730SD 3 for A720B 4 for A733 5 for A723 6 for A440 7 for A733 GSM 8 for A731 9 for A732 REMARKS REMOTE EXAMPLE PORT AVAILABLE FOR DESCRIPTION PARAMETERS slot and samples are the actual values programmed by means of the SLOT command po is the power output of the device during the last frame sent; this value is relative (50 mW corresponds to a value of approx. 25 while 500 mW corresponds to a value of approx. 200) (irrelevant for the A733GSM) err_level is the error value; 0 means no error GET only. Yes, GET only. The A733 can issue the command both remotely and locally. INFO 9193 INFO 255 0 18/4/1999 21:5:11 1.3 0 0 0 91 72 40 1:46 58 65 72 3 900 15 175 0
A731 A732 A733 A733GSM A complex command acting upon the I/O ports of a device. A control byte specifying the command, the bit of the port the command is acting on, and two 16-bit parameters, depending on the control byte; for some commands, one or both of them may be missing. However, if they are needed for a certain command but not given, null values are implied. The control bytes significance is shown in Fig. 17. Command Code Port Number Fig. 17:
The Control Byte Layout The Port Number selects a the port that will be affected by the command. For the A733, only 0000 to 0011 are accepted (only four ports are available). 33 Using terminal commands The Command Code specifies the operation that will be applied to the selected port. They are explained in the table below. Parameters Returns None Code Description 0000 RDP Read Data Port. This command reads the whole 16-bit port and returns its value; the Port Number has no significance for this command 0001 RDDR Read Data Direction Register. This command reads the whole 16-bit Data Direction Register and returns its value; the Port Number has no significance for this command. 0010 CAI Configure the port specified by Port Number as input (acts upon the Data Direction Register). 0011 CAO Configure the port specified by Port Number as output (acts upon the Data Direction Register). 0100 RBV Read the specified bit. 0101 RNS Read the notification2 status. If no notification was pending, this command returns an error. Even in this case the time stamp of the last valid notification is returned. If a notification was pending, it will be cleared. 0110 DNOPC Disable Notify On Port Change. 0111 ENOPC Enable Notify On Port Change. 1000 RPNNER Read the Pending Notifications and the Notification Enable Register. This command returns the 16-bit Pending Notifications and the Notification 2 See also Notifications on page 43. 34 None The port number The port number The port number The port number The port number The port number None A 16-bit integer and the result (OK or ERROR). Only the lowest four significant bits reflect valid ports for the A733 A 16-bit integer and the result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Bit value and the result (OK or ERROR). Returns the time of the last port change in standard time format and the result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Two 16-bit integers
(first the PN and then the NE register) and the result (OK or ERROR). Performing Advanced Functions Code Description Enable Registers; the Port Number has no significance for this command. 1001 CB Clear the specified bit. 1010 SB Set the specified bit. 1011 XB Exclusive Or the specified bit. 1100 MFR Monostable function, start with the specified bit in OFF state
(reset). 1101 MFS Monostable function, start with the specified bit in ON state
(set). 1110 MVFR Multivibrator function, start with the specified bit in OFF state
(reset). 1111 MVFS Multivibrator function, start with the specified bit in ON state
(set). Parameters Returns Result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). Result (OK or ERROR). The port number The port number The port number The port number, the OFF and the ON times (in seconds), both as 16-
bit integers. The port number, the ON and the OFF times
(in sec-
onds), both as 16-bit integers. The port number, the ON and the OFF times
(in sec-
onds), both as 16-bit integers. The port number, the ON and the OFF times
(in sec-
onds), both as 16-bit integers. RETURNS REMARKS The return result depends on the control byte. However, whatever the return result is, it includes the control byte. The general behavior is that a PORT command issued on a certain port bit will override any previous PORT commands. For example, if a port was configured as 35 Using terminal commands input and then an MFR (monostable function) was issued, the port automatically switches to output. A new MFR or similar function clears the status of the port and starts from scratch, even if the previous command was not finished. The A733 cannot issue the PORT command remotely, but can execute it. For RDP:
PORT 0 9193 PORT 0 1 0
For RDDR:
PORT 16 9193 PORT 16 0 0
For ENOPC:
PORT 112 9193 PORT 112 0
For RPNNER:
PORT 128 9193 PORT 128 0 1 0
For RNS:
PORT 80 9193 PORT 80 7/5/1999 18:34:22 0
A731 A732 A733 A733GSM Switches the unit to permanent receive mode (for tuning purposes). None. Nothing. The system stops, and exits the command only when a key is pressed. This command returns no message. No. RX 9193 RX 0
A731 A732 A733 A733GSM Switches the unit to transmit mode (for tuning purposes). None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated carrier), 0
(sends a 2 kHz modulated carrier) or 5 (sends a mixed 1 + 2 kHz modulated carrier). Nothing. EXAMPLE RX AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE TX AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS 36 REMARKS REMOTE EXAMPLE B AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE BLST AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE Performing Advanced Functions The system stops, and exits the command only when a key is pressed. This command returns no message. Not applicable to the A733GSM. No. TX 9193 TX 0
TX 1 9193 TX 0
TX 5 9193 TX 0
A731 A732 A733 A733GSM Sends a broadcast frame. None. A data block. After the device sends the broadcast frame, it will listen for answers. All valid answers will be listed with their IDs. Not applicable to the A733GSM. Yes. A device getting this frame would have to wait for a random time (2 to 10 seconds) before performing the actual broadcast; if no terminal is active, then no results will be listed. A list of heard stations with their RF levels will be updated in the memory and available whenever the BLST command is issued. B 9193 B 0
#234 BA 0
#7851 BA 0 A731 A732 A733 A733GSM Lists the stations heard after the last broadcast command was issued. None. The date and time when the broadcast was performed, the number of stations heard, and a list with the heard stations ID and their respective RF levels. GET only. Not applicable to the A733GSM. Yes. The remote version will list only the first 9 stations heard. BLST 9193 BLST 10/12/1999 12:15:04 4 2008 150 2003 177 6883 168 4027 220
37 Using terminal commands VER AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE Note:
SDI AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS A731 A732 A733 A733GSM Requests the firmware version of the device. None. The current version. GET only. No. VER 9193 VER 1.0.17 0
This command is provided only for compatibility with older units. The host software may use this command to identify the unit it is communicating with. After detecting that the device supports this protocol, the INFO command must be used for further details, if available. A731 A732 A733 A733GSM A complex command that can be used to check the status of the SDI-12 subsystem, as well as configure it. The command has a multitude of options. If issued without parameters, the GET variant is implied, i.e. the status of the SDI-12 subsystem will be returned (see also bellow). The full extend of the commands is not given here as the configuration of the SDI-12 subsytem is done via the wireless link by means of the GUI configurator in the A840 Telemetry Gateway. Additional information can be obtained from Adcon Telemetry upon request. Following information is supplied in the form of a string of characters (the GET variant):
a/A The presence of the SDI-12 adapter: a absent, A present;
w/W The system is in wait state: w not waiting, W waiting for an SDI-12 sensor;
m/M Measurement command started: m no measurement is being done, M a measurement is in progress;
v/V Values for storage available: v no values are available, V values are available for local storage;
d/D autodiscovery autodiscovery pending (will be done at the next sensor poll cycle). initiated: d no autodiscovery pending, D In addition, for every programmed SDI-12 sensor, following information will be listed:
sensor id the sensor ID in ASCII (0 - 9, A - Z and a - z);
method + CRC the measuring method, either M (normal) or R
(continuous), optionally followed by the CRC flag (C);
index the indices used (in hexadecimal), e.g.: 0x3 if indices 0 and 1 are used. 38 Note:
REMARKS REMOTE EXAMPLE Performing Advanced Functions For further information about the significance of the above terms please consult also the SDI-12 standard specification, version 1.3 (http://www.sdi-12.org). SET/GET. Yes. 12225 sdi 12225 sdi AWmVd 3 0 M0 0x9 0 M2 0x20 7 M5 0x1 0 OK
DATASDI AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS A731 A732 A733 A733GSM Returns a slot of SDSI-12 sensor data, if any. Offset and date/time, both optional. If an offset is specified, then only the values after the offset are returned, all other are skipped. The date/time specifies the first slot to be retrived that is strictly younger than the specified time stamp. The data block returned will typically contain a number of data frames (telegrams). The structure of a block is as follows:
dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy ... dn cs where:
dd mm yyyy is the date hh mm ss is the time si is the size of the frame (variable for the SDI frames) ft is the frame type (60 or 61 for the A733) d1 d2 ... dn are the data values (the frame content) cs is a 16-bit checksum obtained by summing the bytes and discarding the carries over 0xFFFF The composition of the data block of such a frame (the values marked as d1, d2... dn) is depicted in Fig. 18, while the digibyte is depicted in Fig. 19. 39 Using terminal commands A733 A732 / A731 RF incoming RF outgoing Digibyte I/O A Pulse Counter I/O B Pulse Counter I/O C Pulse Counter I/O D Pulse Counter Battery I/O A Cabling 1 I/O A Cabling 2 I/O A Cabling 3 I/O B Cabling 1 I/O B Cabling 2 I/O B Cabling 3 I/O C Cabling 1 I/O C Cabling 2 I/O C Cabling 3 I/O D Cabling 1 I/O D Cabling 2 I/O D Cabling 3 SDI count SDI offset SDI available SDI data block RF incoming RF outgoing Digibyte I/O A Pulse Counter I/O B Pulse Counter Battery I/O A Cabling 1 I/O A Cabling 2 I/O A Cabling 3 I/O B Cabling 1 I/O B Cabling 2 I/O B Cabling 3 SDI count SDI offset SDI available SDI data block Fig. 18:
Frame 60,61 (left) and 62 (right) description The frame is similar to the standard DATA frame, but has the SDI sensor values appended after the standard analog values. The frames type 60 contain SDI-12 only data. SDI-12 specific parameters are explained below:
SDI count represents the number of SDI values following in the SDI data block. SDI offset the offset in the SDI-12 frame. Usually it is 0 (no offset is used). SDI available is the number of SDI-12 sensor values effectiveky returned. The difference between the SDI count and SDI available indicates missing sensors (down or damaged). Usually these two values are equal. SDI values it is a number of SDI-12 data blocks, each consisting of four values:
SDI address SDI method SDI index 40 Performing Advanced Functions SDI value (floating point).
(see also the example below) For additional information on the significance of the SDI address, method and index, please see also the SDI-12 standard specification (http:// www.sdi-12.org). The digibyte is similar to the DATA command:
b7 b0 SC Dig6 Dig5 Dig4 Dig3 Dig2 Dig1 Dig0 SC-Battery Charge (0-off, 1-on) Fig. 19:
Dig n Digital I/O n The Digibyte The remote version is limited to a single frame. GET only. Yes. 12800 datasdi 12800 datasdi 16 5 2003 20 14 49 44 60 255 255 127 87 9 0 9 3 0 0 74.379401 3 0 1 68.117003 3 0 2 58.832397 3 0 3 51.611795 3 0 4 38.346400 3 0 5 19.800799 3 0 6 14.895999 3 0 7 3.553500 3 0 8 0.037200 2953 0
A731 A732 A733 A733GSM Sets/returns the maximum delay for waiting awake (i.e. out of sleep mode) for a service request of an SDI-12 sensor. This parameter is set to 30 seconds by default. A larger value may lead to higher power consumption. This should be used in cases an SDI-12 sensor needs large time values to return a sensor result. If you have such sensors and still want to use them, you need to change this parameter, but please be aware of the fact that the RTUs power consumption will be higher. Maximum wake time in seconds (1 to 999). The current value (in seconds). SET/GET. No. SDA 29000 SDA 30 0
SDA 50 29000 SDA 0
REMARKS REMOTE EXAMPLE SDA AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE FPC AVAILABLE FOR DESCRIPTION: This command allows the use of sensors which generate pulses with frequencies A731 A732 A733 A733GSM from 0.5Hz up to 30Hz. 41 PARAMETERS: 0: let processor enter power save mode and thus not catch "fast" pulses. Using terminal commands RETURNS:
REMARKS:
REMOTE:
EXAMPLE:
1: enable RTU to count "fast" pulses. NONE: display current setting. The current setting, or the commands success or error code. GET/SET, starting from RTU firmware version 2.2.0. No. FPC 193 FPC 0 0
FPC 1 193 FPC 0
FPC 193 FPC 1 0
GSMPIN AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE A731 A732 A733 A733GSM Allows entering the PIN code for activating the SIM card. The PIN code. Result: success or error (error if wrong PIN code entered). SET only. Valid for the A733GSM RTU only. No. GSMPIN 1234 29000 GSMPIN 0
GSMPUK AVAILABLE FOR DESCRIPTION PARAMETERS RETURNS REMARKS REMOTE EXAMPLE A731 A732 A733 A733GSM Allows entering the PUK code for recovering a lost PIN code. The PUK and the PIN codes. Result: success or error (error if wrong PUK code entered). SET only. Valid for the A733GSM RTU only. No. GSMPUK 12345678 1234 29000 GSMPUK 0
GSMSTAT AVAILABLE FOR DESCRIPTION PARAMETERS A731 A732 A733 A733GSM Returns GSM module related status information. None. 42 RETURNS REMARKS REMOTE EXAMPLE Note:
Performing Advanced Functions Result: a list of current status parameters. The list is self-explanatory. GET only. Valid for the A733GSM RTU only. No. GSMSTAT GSM modem on: Yes SIM card found: Yes PIN set: Yes PIN accepted: Yes Sleepmode OK: Yes PUK required: No Default IMEI nr: No Attempts left to enter PIN: 3, PUK: 10 0
The A733GSM RTU can be called via the GSM interface from a standard modem. The command line interface is therefore remotely accessible. In this respect, many commands that are otherwise as not remotely accessible can be in fact accessed remotely. 3.5 Notifications Notifications are frames sent asynchronously by devices that are otherwise slaves. The notifications are received by a device closest to the host and then sent to the host. If the host is not available, the receiving device will store the notification and wait until it is questioned by the host. At this point, it will inform the host that it has a notification. It is then the task of the host to issue a command to read the respective notification. Before a device can issue a notification, the notification must first be enabled. Special frames are used to this end, depending on the notification type. If an end device is not able to send a notification due to radio propagation or other kinds of communication problems, it will store the date/ time when the notification took place. As soon as the communication is re-established, the device will try to send the notification again. To avoid collisions, the device will wait a random time (up to 10 seconds) before sending the notification frame. The following notifications are currently implemented for the A733 device:
NOPCNotification On Port Change (see PORT on page 33);
NOTRNotification On Threshold Reached (see ANLG on page 26). The A733GSM RTU currently does not suppport notifications. Note:
Note:
3.6 Returned errors list Following are error messages you might get. 43 Returned errors list 3.6.1 Command line interpreter 1 nonexistent command 2 command line buffer overflow (input line too long) 3 internal error 4 reserved 5 missing or false parameters in command 6 operation not implemented 7 remote operation not allowed 8 Invalid IMEI checksum number 3.6.2 Device descriptors and storage handler 10 device not found (attempt to perform a command on a nonexistent device) 11 device already exists 12 reserved 13 no more space for descriptors (too many devices) 14 no more records for the specified device 15 temporary communication break, no more data (the last request was not successful) 16 time-out (the handler blocked or is busy) 17 internal error 18 attempt to insert a reserved device ID number (0 or 65535) 3.6.3 Real time clock 20 incorrect time supplied (conversion to time_t was not possible) 3.6.4 Radio interface 30 error at receive (CRC, etc.) 31 unexpected frame received 32 wrong length 33 reserved 34 reserved 35 time-out (remote device not responding) 36 receiver busy (for example, just making the request round) 37 time stamp of a frame is too far in the future 38 general modem error 44 Performing Advanced Functions 3.6.5 Notifications 40 request to read a notification when no notification is pending 45 Specifications 4 Specifications Note:
The A733 was intended to fulfill the specification of the EN 300 220-1, and ETSI 300 113, as well as the FCC Part 90, Subpart J of the CFR 47. Table. 2 shows the main operational parameters of the A733. The parameters below are measured with an A733 + A431 combination. Parameter Common Supply Operating Temperature Relative Humidity Class Protection Data Rate (Using the on-board software modem)3 Dimensions Weight Data Acquisition Subsystem Analog Inputs Analog Inputs Resolution Analog Inputs Accuracy Analog Input Range Digital I/O Digital I/O Zero Level 3 Data rate is content dependent. Max 10.0
+70 99 2000 Min 5.6
-30 1000 Typ 6.2 IP65 1500 16(L) x 8(W) x 6(D) 6.25 x 3.15 x 2.4 1.15 3 12 6 0 0 4 2 0
(A733 and A733GSM)
(A732)
(A731) 10 0.1 2.5
(A733 and A733GSM)
(A732)
(A731) 0.2 Unit V 0C
bps cm in kg Ib bits
V V 47 Returned errors list Parameter Digital I/O One Level Pulse Counters Pulse Counter Speed Pulse Counter Input Levels
(Counting on Leading Edge) Sensor Supply Current
(Switched Output) Sensor Settling Time Data Memory Size Sampling Rate Storage Interval Other Interfaces Serial Interface (3V TTL) Zero Level Serial Interface (3V TTL) One Level Battery Management Charge Current (External Battery) Radio Subsystem (Receive /
Transmit Not Valid for A733GSM) Operating Frequency (low-band version)4 Operating Frequency (high-band version) Frequency Stability (-20 to +50 C) Frequency Stability (-30 to +60 C) Receiver (Not Valid for A733GSM) Sensitivity (12 dB S/S+N) Image Frequency Attenuation
(1st IF=45MHz) Local Oscillator Leakage Adjacent Channel Attenuation RSSI dynamic Operating current (incl. On-board microcontroller) Min 4 2 0 0 0 60 430 450
-70
-70 90 Transmitter (all measurements made on 50Ohm resistive load not Valid for A733GSM) Typ 2.4 Max
(A733 and A733GSM)
(A732)
(A731) Unit V 2 1024 0.2 2.4
-118 2 2.4 500 255 65535 pulses/s V mA s Slots samples
/slot s V 0.8 450 470 1.5 2.5 2 32 27 V A MHz MHz kHz kHz dBm dB nW dB dB mA dBm Output power 24 26 4 This parameter represents the alignment range; the switching range can be limited in the software to a narrower space (even to the extent of a single channel). 48 Specifications Parameter Spurious Radiation Adjacent Channel Power
(12,5kHz mode) Adjacent Channel Power (25kHz mode) Operating current(incl. On-board microcontroller) Min Typ Max 200
-34
-44 600 Unit nW dBm dBm mA Table. 2:
Operational Parameters 49 5 Index Index A A440 ....................................................15 A730MD ..............................................10 A733GSM Communication distance................10 PIN code ........................................12 PUK................................................13 SIM Card ........................................11 Special Notes .................................11 A840 Telemetry Gateway....................15 addVANTAGE Software......................15 Advanced Functions............................19 ANLG...................................................26 B B ..........................................................37 Battery .................................................15 Changing........................................16 BLST ...................................................38 C Changing the battery...........................16 CMDS..................................................23 command ANLG..............................................26 B.....................................................37 BLST ..............................................38 CMDS.............................................23 DATA ............................................. 29 DATASDI....................................... 39 FDEV ............................................. 32 FPC ............................................... 42 FREQ............................................. 23 GSMPIN ........................................ 42 GSMPUK....................................... 42 GSMSTAT ..................................... 43 ID ................................................... 24 IMME ............................................. 32 INFO .............................................. 32 PMP............................................... 25 PORT............................................. 34 RSSI .............................................. 24 RX.................................................. 37 SDA ............................................... 41 SDI................................................. 38 SLOT ............................................. 25 SST................................................ 25 TIME .............................................. 23 TX .................................................. 37 VER ............................................... 38 Command General format............................... 22 Compliance Statement ......................... 6 connectivity check .............................. 13 Connector I/O Connector ................................ 20 Power Connector........................... 20 51 R Returned error .................................... 44 RSSI ................................................... 24 RTU Battery ........................................... 15 Changing the battery ..................... 16 configuration.................................. 15 Connectors .................................... 19 Maintainance ................................. 15 Service........................................... 15 RX....................................................... 37 S SDA .................................................... 41 SDI...................................................... 38 Sensor Power consumption....................... 15 Serial communication protocol ........... 22 Serial Port Configuration ................................. 21 SLOT .................................................. 25 Solar Panel ........................................... 9 Specification ....................................... 47 SST..................................................... 25 T Terminal commands ........................... 23 TIME ................................................... 23 TX ....................................................... 37 U Using the A73x RTU............................. 9 V VER .................................................... 38 W Warnings............................................... 6 Index D DATA...................................................29 DATASDI.............................................39 Distance ..............................................10 F FCC Rules.............................................7 FDEV...................................................32 FPC .....................................................42 FREQ ..................................................23 G GSMPIN ..............................................42 GSMPUK.............................................42 GSMSTAT ...........................................43 H Hyperterminal......................................21 I ID.........................................................24 IMME ...................................................32 INFO....................................................32 Installing the RTU................................10 Introduction............................................5 L LED tool.....................................9, 13, 14 N Notifications.........................................43 P PMP.....................................................25 Pole .......................................................9 PORT ..................................................34 Power Connector................................20 52
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2005-04-18 | 450 ~ 470 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2005-04-18
|
||||
1 | Applicant's complete, legal business name |
Ott Hydromet GmbH Business Unit Adcon Telemetry
|
||||
1 | FCC Registration Number (FRN) |
0011471562
|
||||
1 | Physical Address |
Inkustr. 24
|
||||
1 |
Klosterneuburg, N/A A-3400
|
|||||
1 |
Austria
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
m******@tuev.or.at
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
SHX
|
||||
1 | Equipment Product Code |
A731-46
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G******** C********
|
||||
1 | Telephone Number |
+43-2******** Extension:
|
||||
1 | Fax Number |
+43-2********
|
||||
1 |
g******@ott.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Telemetry transceiver | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV Austria
|
||||
1 | Name |
I******** S********
|
||||
1 | Telephone Number |
43-1-******** Extension:
|
||||
1 | Fax Number |
+43 1********
|
||||
1 |
s******@tuev.or.at
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 90 | BC | 450.00000000 | 470.00000000 | 0.5000000 | 1.5000000000 ppm | 8K50F1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC