PT40 OEM User Manual Version 1.0 PT40 OEM USER MANUAL Table of Contents 1 Version Tracking ................................................................................................... 4 2 OEM Notice ............................................................................................................... 5 3 Product Overview .................................................................................................. 5 4 External Interfaces ................................................................................................ 6 Overview ....................................................................................................................................... 6 4.1 4.2 Pinout ............................................................................................................................................ 6 4.3 USB-C ............................................................................................................................................. 7 5 LEDs ........................................................................................................................... 7 Overview ....................................................................................................................................... 7 5.1 5.2 5.3 ORANGE LED ................................................................................................................................. 8 GREEN LED .................................................................................................................................... 8 5.4 BLUE LED ....................................................................................................................................... 8 6 Power Supply .......................................................................................................... 8 7 Testing Environment ............................................................................................ 9 8 Software Tools ........................................................................................................ 9 9 Initial setup ............................................................................................................. 9 10 Control Interface .................................................................................................. 10 11 Cellular Information ........................................................................................... 10 11.1 Query normal .............................................................................................................................. 10 11.2 Query no SIM .............................................................................................................................. 11 12 GPS Information ................................................................................................... 11 13 Input/Outputs ....................................................................................................... 12 13.1 Overview ..................................................................................................................................... 12 13.2 Digital inputs ............................................................................................................................... 12 13.3 Open-drain outputs..................................................................................................................... 12 13.4 Connecting a load ....................................................................................................................... 13 Pacific Track, LLC 2 PT40 OEM USER MANUAL 13.5 1-Wire interface ....................................................................................................................... 14 13.6 Serial interface ............................................................................................................................ 14 Pacific Track, LLC 3 PT40 OEM USER MANUAL 1 Version Tracking Version 0.1 0.2 0.3 1.0 Date 11/19/2017 9/17/2018 9/18/2018 1/28/2019 Change Initial Version Updated Comments from CC Published Pacific Track, LLC 4 PT40 OEM USER MANUAL 2 OEM Notice This user manual is provided to OEM and Resellers of Pacific Tracks products. It is not intended to be used by end users. OEM and Resellers should include the following notices in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed:
Product Marketing Name: Telematics Device FCC ID: 2ALBDPT40 IC :
23259-PT40 This equipment complies with FCC radiation exposure limits and Canada radiation RF exposure limits set forth in CFR 47 Sections 2.1091 and ISED RSS-102 for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux rayonnements de la FCC et aux limites d'exposition aux rayonnements RF du Canada nonces dans les sections 2.1091 du CFR 47 et ISED RSS-
102 pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20 cm entre le radiateur et votre corps. Cet metteur ne doit pas tre colocalis ou fonctionner en conjonction avec une autre antenne ou metteur. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canadas license-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 3 Product Overview The PT40 is a cellular device that can be used for both simple and complex telematics application. In simple application the PT40 can be powered with a basic power-only connection. In more complex Pacific Track, LLC 5 PT40 OEM USER MANUAL application, the PT40 cab be connected to digital inputs and outputs, temperature sensors, iButton and additional devices over a serial connection. The PT40 can also be connected to vehicle bus to augment the telematics data with information collected directly from the vehicle. The PT40 supports J1939, J1708/1587 and OBD-II (CAN only). Thanks to the integrated Bluetooth Low Energy interface, the PT40 can also communicate with an external device such as a smartphone or tablet. Finally, the PT40 can be programmed to run complex applications schemes based on locally generated events and states. 4 External Interfaces 4.1 Overview The PT40 uses a single external interface. The interface is a 20-pin connector Molex Micro-Fit 3.0 P/N 04304-52009. The mating connector is the Molex 04302-52000. Pacific Track has approved the substitution of the Molex connector with other brands that have met a series of tests conducted internally. 4.2 Pinout Pacific Track, LLC 6 PT40 OEM USER MANUAL The pinout of the connector is specified is the following table:
PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FUNCTION POWER_OUT UART RX BATTERY OUTPUT 2 1-WIRE INPUT 4 INPUT 2 J1708+
CAN HIGH POWER IN GND UART TX VDC OUTPUT 1 GND INPUT 3 INPUT 1 J1708-
CAN LOW POWER GND DETAILS / RANGE
+3V switched power Accessories UART Receive Internal Battery (do not use) Open Drain Output 1-Wire Interface 3 to 32V 3 to 32V J1708 Interface J1939 or OBD-II 6 to 32V Ground for accessories Accessories UART Transmit DC/DC converter Output (do not use) Open Drain Output Ground for 1-Wire 3 to 32V 3 to 32V J1708 Interface J1939 or OBD-II 0V The device should be powered from pins 10 and 20. 4.3 USB-C For debugging purpose, the PT40 also includes a USB-C connector. The USB-C connector can be used to connect USB 2.0 equipment (PC, laptop or smartphone) to the PT40. Note that the PT40 cannot be powered from the USB-C connector nor can the connector provide power to a connected accessory. 5 LEDs 5.1 Overview The PT40 includes three LEDs (ORANGE, GREEN and BLUE). Note: This document describes the current default behavior of the LEDs. This behavior can be changed by the user. Pacific Track, LLC 7 PT40 OEM USER MANUAL 5.2 ORANGE LED The following table summarizes the functionality of the ORANGE LED;
LED State Off Blinking On Meaning GPS power management engaged. GPS is turned off, GPS backup clock in ON. GPS is in acquisition mode GPS signal is locked Note: In production mode, the GPS chipset will go into power management mode (GPS OFF, RTC ON) to save power. 5.3 GREEN LED One short blink every 10 second 5.4 BLUE LED The following table summarizes the functionality of the BLUE LED;
LED State Off One blink / 10s Fast blink Slow Blink On Meaning The cellular subsystem is off The cellular subsystem is not searching The cellular network has rejected the device The cellular subsystem is searching The cellular subsystem found a network Note: The GPS may go into power management mode for example when the PT40 detects that the vehicle is not moving. 6 Power Supply The PT40 is powered with a circuit that has been tested to meet the requirements of ISO 16750-2. The circuit provides the following benefit:
1) Protected against reversed polarity 2) Protected against over current with a resettable fuse 3) Filtered against noise present on the power line Pacific Track, LLC 8 PT40 OEM USER MANUAL 4) Protected against the overvoltage/overshoot present in the automotive and industrial environments with a Transient Voltage Suppressor (TVS) which has a peak power dissipation of 1500W 7 Testing Environment To test the PT40, the following shall be provided:
A reliable power supply (at least one amp at 12V) A SIM card for the targeted operator A PC or laptop A USB cable to connect a PC or laptop to the PT40 such as this one:
8 Software Tools It is recommended to use a terminal emulation program called Tera Term. The latest version is 4.100 and it can be found at: https://osdn.net/projects/ttssh2/releases/
Do not use other branches of the Tera Term projects such as 2.x or 3.x 9 Initial setup Insert the SIM card in the PT40 1. 2. Power the device 3. Connect the USB connector to the PC/Laptop and to the device 4. On a recent operating system (Windows 10), you will be prompted to install a device named STM32 Virtual ComPort and the driver will be automatically installed 5. Start Tera Term Pacific Track, LLC 9 PT40 OEM USER MANUAL 6. Click on File New Connection Serial and select the port that was just installed 7. Click OK 8. Click on Setup Serial Port and select the following options:
Speed: 115200 Data: 8 bit Parity: none Stop bits: 1 bit Flow control: none 9. Click OK 10. It might be convenient to store those settings by going to:
Setup Save setup and click Save 10 Control Interface At that point the user should be able to enter commands to control and query the device. Note that there is no echo unless the command character (!) is first entered. To test the interface, type the following commands:
!H<cr>
(<cr> is the carriage return character which is sent when the Enter key is pressed) 11 Cellular Information 11.1 Query normal The Cellular interface can be queried with the following command:
!CI<cr>
Here below is an example answer to this query:
H/W Model: SARA-R410M-02B Revision: L0.0.00.00.05.06 IMEI: 352753090114156 CAT-M: B2 B4 B5 B12 SIM Status: OK ICCID: 89011703278144196279 IMSI: 310170814419627 NETWORK Registered: Yes Pacific Track, LLC 10 PT40 OEM USER MANUAL Roaming: No RSSI: 26 Network: 310410 LAC: FFFE CID: 08720B0F OK The following line:
CAT-M: B2 B4 B5 B12 Shows which LTE bands that have been enabled on that specific module. The following bands should be active:
Country US US FR Bands 2, 4, 5 and 12 4 and 13 3 and 20 Operator AT&T Verizon Orange 11.2 Query no SIM If the SIM card is not present or not detected, the following is displayed:
H/W Model: SARA-R410M-02B Revision: L0.0.00.00.05.06 IMEI: 352753090114156 SIM Status: No SIM NETWORK Registered: No OK 12 GPS Information The GPS subsystem can be queried with the following command:
!G<cr>
Here below is an example answer to this query:
GPS STATUS Mode: Power ON Lock: 1 Pacific Track, LLC 11 PT40 OEM USER MANUAL Sat U: 11 Sat V: 14 Time: 09/17/2018 22:12:51 Lat: 48.858343 Lon: 2.294705 Spd: 0.0 Hea: 257 Alt: 23 DOP: 0.8 Age: 1 s RTC: 09/17/2018 22:12:50 Lock: 35 Relock: 35 OK 13 Input/Outputs 13.1 Overview The PT40 includes the following interfaces:
4 Digital inputs 2 Open-drain outputs A 1-Wire interface A serial UART For debugging purpose, these interfaces can be controlled locally. In actual deployments, these interfaces can be controlled remotely over an IP connection or SMS messages 13.2 Digital inputs The inputs can be verified with the following command:
!INP<cr>
The result is as shown below:
4 3 2 1 0 1 1 0 OK In that case, inputs 2 and 3 are high (more than 3V on the input) and inputs 1 and 4 are low. 13.3 Open-drain outputs The outputs can be controlled with the following command:
Pacific Track, LLC 12 PT40 OEM USER MANUAL
(1 activates the open-drain which grounds the output))
!OUT=<OUTPUT>,<LEVEL>
<OUTPUT> is 1 or 2
<LEVEL> is 0 or 1 Example 1: activate output #2:
!OUT=2,1 Example 2: deactivate output #1:
!OUT=1,0 13.4 Connecting a load The load can be connected to any of the two PT40 outputs using the following schematic:
Please note the following:
Pacific Track, LLC 13 PT40 OEM USER MANUAL The POWER applied to the load does not need to be the same as the one powering the PT40 When using separate power sources, the two grounds (PT40 and load) must be connected together The diode shown above must be present if the load is not purely resistive. If a non-resistive load such as a relay is switched without the diode, the PT40 output will be immediately destroyed. The maximum voltage for the load is 60V (note that this is different from the maximum voltage supported by the PT40 itself) The maximum current is 3 Amps. 13.5 1-Wire interface The PT40 supports iButton and temperature sensors. 13.6 Serial interface Please contact Pacific Track to discuss the supported devices. Pacific Track, LLC 14