Wireless electricity
sensor familyoverview
Our electricity sensor series is comprised of non-invasive, self-powered, miniature
wireless current sensors. The sensors clamp onto the electrical outgoing wire from
thecircuitbreakerandare self-poweredbythe circuit’smagneticfield.Hundreds
of sensors canbe installed ina few hourswith nodisturbance to daily operations.
Once installed, the sensors become part of the building infrastructure, never
requiring maintenance, service or batteryreplacement.
PAN-14P wireless high current sensor specifications
Physical dimensions
Current input range
33.8 × 29 × 42.5 mm
1.33 × 1.14 × 1.67 inch
0 – 5 A (up to 10 A peak)
(fromexternal currenttransformer)
Current measurement range
Determined by external current transformer
Current measurement accuracy
Typically <2% at I > 0.1 A (at input from external CT)
Minimum operating current
0.03 – 0.05 A (at input from external CT)
AC frequency supported
Transmission frequency
Transmission power (ERP)
60 Hz
915 MHz
0 dBm (max)
Transmission interval
10 seconds
The PAN-14P high-current
sensor attaches to any size
standard
0 – 5 Acurrent transformer,
allowing measurements at
any current range or wire gauge.
Wireless electricity
sensor familyoverview
PAN-14P wireless high current sensor
specifications
Certification1
Key features
• Connects to any standard 5 A
current transformer
• No maintenance; self-powered
• High accuracy
• Wireless sensor and CT are
closedaround the hot wire
with no additional wiring
• Real-time
data
transmitted every 10seconds
current
USA and Canada
Safety: UL 61010-1, UL 61010-2-030, CAN/CSA-C22.2
No. 61010-1 (ETL listed)
EMC: FCC Part 15 subpart B, ICES-003
Radio: FCC Part 15 subpart C, RSS-210, RSS-Gen
Europe
Safety: EN 61010-1, EN 61010-2-030 (CE)
EMC: EN ETSI 301 489-1, 301 489-3, 613 326-1
Radio: EN ETSI 300 220-1, 300 220-2
Australia
ACMA compliant
Russia
EAC compliant
Japan
Radio: ARIB STD-T108
CB Certification IEC 61010-1, IEC 61010-2-030
by Intertek Testing Services
Flammability rating of external enclosure
UL94 V-0
Ingress protection (IP) rating
IP5X
Operating temperature
-25 – 60°C / -13 – 140°F
Operating humidity range
5% – 95% non-condensing
Storage temperature
-25 – 65°C / -13 – 149°F
Wireless electricity
sensor familyoverview
FCC Warnings
Modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment under
FCC Rules.
ISED Warning (Modification statement)
Panoramic Power n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout
changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur.
RF Exposure Warnings
Mobile Device RF Exposure Statement
Statement in UM
Interference statement
RF Exposure - This device is only authorized for use in a mobile application. At least 20 cm of separation distance between
the PAN-14-P Sensors and the user's body must be maintained at all times.
This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Wireless notice
This device complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment and meets the FCC
radio frequency (RF) Exposure Guidelines and RSS‐102 of the ISED radio frequency (RF) Exposure rules. This transmitter
must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme à l'exposition aux radiations FCC / ISED définies pour un environnement non contrôlé et
répond aux directives d'exposition de la fréquence de la FCC radiofréquence (RF) et RSS‐102 de la fréquence radio (RF) ISED
règles d'exposition. L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec à autre antenne ou autre
émetteur.
Wireless electricity
sensor familyoverview
Statement according to FCC part 15.105:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Statement according to FCC part 15.19:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Statement according to FCC part 15.21:
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.