1759MG V2.0 Reference & Installation Manual
(433MHZ / 868MHZ) 1759MG Table of Contents Introduction...................................................................... 1 Features.............................................................................................. 1 Specifications...................................................................................... 1 Installation........................................................................ 2 Location and Mounting ....................................................................... 2 Earth Ground ...................................................................................... 2 AC Power............................................................................................ 2 Backup Battery ................................................................................... 2 Auxiliary Power Terminals*................................................................. 4 Telephone Line Connection................................................................ 4 Bell Output Connection....................................................................... 4 Programmable Output Connections* .................................................. 4 Single Zone Inputs.............................................................................. 5 Keypad and Keypad Zone Connections ......................................... 5 Keyswitch Connections....................................................................... 6 Fire Circuits......................................................................................... 6 Programming Methods.................................................... 7 WinLoad Software for Windows* ........................................................ 7 Programming Using a Keypad............................................................ 7 Configuring The LED Keypad ............................................................. 8 Programming Using A Paradox Memory Key*.................................... 9 Access Codes ................................................................ 10 Access Code Length......................................................................... 10 Installer Code (Default: 0000 / 000000)............................................ 10 System Master Code (Default: 1234 / 123456)................................. 10 User Code Options ........................................................................... 10 Lock Master Code............................................................................. 11 Duress Code..................................................................................... 11 Zone Programming........................................................ 12 What is an Expansion Input? ............................................................ 12 Reassign Keypad Zone 2 ................................................................. 12 Reassign Zones to Expansion Inputs ............................................... 13 Zone Programming ........................................................................... 13 Zone Definitions................................................................................ 13 Exclusive Zone Definitions................................................................ 14 Programming a Wireless Fire Zone .................................................. 15 Zone Partition Assignment................................................................ 15 Zone Options .................................................................................... 16 Zone Speed ...................................................................................... 17 EOL Zones........................................................................................ 17 Wireless Features.......................................................... 18 Wireless Transmitter Programming .................................................. 18 Viewing the Wireless Transmitter Signal Strength............................ 19 Serial Number Display ...................................................................... 19 Supervision Options.......................................................................... 19 Remote Control Programming .......................................................... 20 Arming and Disarming Options.................................... 22 Switch To Stay Arming ..................................................................... 22 Stay Arming with Delay..................................................................... 22 Regular Arming Switches to Force Arming
(Not to be used with UL Installations) ............................................... 23 Restrict Arming on Battery Fail ......................................................... 23 Restrict Arming on Tamper Failure................................................... 23 Timed Auto-Arming........................................................................... 23 No Movement Auto-Arming .............................................................. 23 Auto-Arming Options (Not to be used with UL installations)............. 24 One-Touch Arming (Not to be used with UL installations)................ 24 Exit Delay ......................................................................................... 24 Bell Squawk On Arm/Disarm with Keypad ....................................... 24 Bell Squawk On Arm/Disarm with Remote Control .......................... 24 No Exit Delay When Arming with Remote Control ........................... 24 No Exit Delay Beeps and No Bell Squawk When Stay Arming........ 25 Alarm Options............................................................... 25 Bell Cut-Off Timer............................................................................. 25 Recycle Alarm .................................................................................. 25 Tamper Recognition......................................................................... 25 Keypad Panic Options...................................................................... 26 Panic Lockout Timer......................................................................... 26 Reporting and Dialer settings....................................... 27 Reporting/Dialer (Enable/Disable).................................................... 28 Report Codes ................................................................................... 28 Monitoring Station Telephone Numbers........................................... 30 Partition Account Numbers............................................................... 30 Reporting Formats............................................................................ 30 Pager Delay...................................................................................... 32 Event Call Direction.......................................................................... 32 Dialing Method ................................................................................. 32 Pulse Ratio....................................................................................... 32 Bell on Communication Failure ........................................................ 32 Dial Tone Delay................................................................................ 32 Maximum Dialing Attempts............................................................... 33 Delay Between Dialing Attempts...................................................... 33 Alternate Dial Option ........................................................................ 33 Recent Close Delay.......................................................................... 33 Auto Test Report .............................................................................. 33 Closing Delinquency Timer .............................................................. 33 Power Failure Report Delay ............................................................. 33 Disarm Reporting Options................................................................ 33 Zone Restore Report Options .......................................................... 34 Telephone Line Monitoring (TLM) .................................................... 34 Programmable Outputs................................................ 34 PGM Activation Event ...................................................................... 34 PGM Deactivation Event .................................................................. 35 PGM Delay....................................................................................... 35 PGM Normal State ........................................................................... 35 PGM2 Strobe Options ...................................................................... 35 Alarm Relay Options ........................................................................ 35 System Settings............................................................. 36 Hardware Reset ............................................................................... 36 Installer Lock .................................................................................... 36 Keypad Lockout Feature .................................................................. 36 Battery Charge Current .................................................................... 36 Partitioning ....................................................................................... 36 System Real-Time Clock.................................................................. 36 Clock Adjust ..................................................................................... 36 Keypad Tamper Supervision............................................................ 37 Keypad Audible Trouble Warning..................................................... 37 Confidential Mode ............................................................................ 37 Installer Quick Functions Keys......................................................... 38 PGM Modules Supervision............................................................... 38 Printer Module Supervision .............................................................. 38 Zone Expansion Bus Module Supervision........................................ 38 Wireless Transmitter Low Battery Supervision................................. 39 Wireless Transmitter Supervision Options ....................................... 39 Reprogram All Expansion Modules.................................................. 39 Spectra Series Settings for WinLoad Software .................................... 40 Panel Answer Options ...................................................................... 40 Panel Identifier.................................................................................. 40 PC Password .................................................................................... 40 PC Telephone Number ..................................................................... 40 Call WinLoad Software ..................................................................... 40 Answer WinLoad Software ............................................................... 41 Auto Event Buffer Transmission ....................................................... 41 Call Back WinLoad ........................................................................... 41 User Operation.............................................................. 42 Trouble Display................................................................................. 42 Programming Access Codes ............................................................ 43 Disarming & Deactivating an Alarm .................................................. 43 Regular Arming................................................................................. 44 Stay Arming ...................................................................................... 44 Instant Arming................................................................................... 44 Force Arming (Not to be used with UL Installations) ........................ 44 Manual Bypass Programming........................................................... 44 One-Touch Arming ........................................................................... 45 Keyswitch Arming ............................................................................. 45 Panic Alarms..................................................................................... 45 Auto-Arming (Not to be used with UL installations) .......................... 45 Alarm Memory Display...................................................................... 46 Programming Chime Zones.............................................................. 46 Keypad Muting (Not to be used with UL installations) ...................... 46 Keypad Backlight (1686H and 1686V only) ...................................... 46 FCC Warnings................................................................ 47 Index ............................................................................... 49 List of Tables Transformer Requirements Table....................................................... 2 Current Consumption Table................................................................ 4 Decimal and Hexadecimal Programming Table ................................. 7 Zone Recognition Table .................................................................. 12 Sections and Expansion Inputs ........................................................ 18 Remote Control Button Programming............................................... 21 Button Options .................................................................................. 22 Special Keys for Telephone Numbers .............................................. 30 Reporting Formats ............................................................................ 31 Zone Tamper Report Code for Keypad Tamper Supervision Failure.. 37 Trouble List ....................................................................................... 42 Reference & Installation Manual 1.1 1.2 Part 1: Introduction Features Up to 15 fully programmable zones Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for each partition such as Event Reporting, Entry/Exit Delay, Auto-arming and many more. All zones, the keyswitches and all user codes are assigned to specific partitions, which makes this a true partitioned system. Communication bus facilitates the adding, programming and monitoring of all expansion modules 1 Installer Code and 48 user codes (including: 1 System Master, 2 Masters, and 1 Duress) 2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay Simple, direct and logical programming Event Call Direction: The Spectra 1759MG control panel events are divided into 5 groups of events. Each of these event groups can be programmed with a separate dialing sequence. Two 32-digit monitoring station telephone numbers and one 32-digit Backup Telephone Number Contact ID, Pager Format and many more High-Speed Communication Formats
"False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before Alarm Transmission, and Recent Closing Report Regular arming, Stay arming, Instant arming, Force arming, One-touch arming, Auto-arming, or Keyswitch arming 256 Event Buffer with time stamp Telephone Line Supervision Keypad activated panic alarms Compatible with Winload Security System Management Software for Windows Specifications 1.2.1 Spectra 1759MG Control Panel AC Power:
Battery:
Aux. Power:+
Bell Output:++
PGM Outputs:
Alarm Relay:
Approvals:
16Vac transformer (refer to Table 1 on page 2) with minimum 20VA rating (Rec.:
40VA), 50 to 60Hz 12Vdc, 4Ah/7Ah 600mA typical, 700mA maximum, fuseless shutdown @ 1.1A 1A, fuseless shutdown @ 3A PGM1 = 150mA low-current output, PGM2 = 1A high-current output One form C relay rated @ 125V, 5A receptive load 433MHz 868MHz to RTT&E directives. Compliant to all EU and EFTA countries except Greece according 1.2.2 Spectra Keypads (1686H, 1686V, 1689 and 1641) Power input:
1 standard keypad zone On-board anti-tamper switch (optional) Typically 9-16Vdc 1686H and 1686V 10-Zone LED Keypad Current consumption:
62 to 116mA 1689 16-Zone LED Keypad Current consumption:
50 to 117mA 1641 32-Character LCD Keypad Current consumption:
PGM:
LCD:
Specifications may change without prior notice
+ Cannot exceed 200mA for UL installations
++ Cannot exceed 1A for UL installations 60 to 80mA 1 with 50mA current limit Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast adjustable Spectra 1759MG 1 Part 2: Installation 2.1 2.2 2.3 Location and Mounting Before mounting the cabinet, push the five white nylon mounting studs into the back of the cabinet. Pull all cables into the cabinet and prepare them for connection before mounting the circuit board into the back of the cabinet. Select a centralized installation site on the main floor that isn't easily accessible to intruders and leave at least 5cm (2in) around the panel box to permit adequate ventilation and heat dissipation. The installation site should be dry and close to an AC source, ground connection and telephone line connection. Avoid installation near or in the path of strong RF fields (i.e. neon lights, computers), on or near metal objects, circuit breaker boxes, air conditioners and heater ducts since they may cause interference and reduce sensitivity. Avoid installing the 1759MG in the basement. Do not cut, bend or alter the antennae and ensure that electrical wires do not cross over the antennae as these may affect the signal reception. Earth Ground Connect the zone and dialer ground terminals from the control panel to the metallic enclosure and cold water pipe or grounding rod as per local electrical codes. For maximum lightning protection, use separate earth grounds for the zone and dialer grounds as shown in Figure 2 on page 3. For UL installations, the metallic enclosure must be grounded to the cold water pipe. AC Power Do not use any switch-controlled outlets to power the transformer. Connect the transformer as shown in Figure 1 on page 2. Use Table 1 to determine the required transformer. Table 1: Transformer Requirements Table Transformer:
Spectra DC Power Supply rated at:
Auxiliary Supply can provide a maximum of:
Amseco XP-1620 16VAC 20VA
(not verified by UL) 1.2A typ: 600mA, max: 700mA Acceptable Battery Charge Currents 350mA UL: Basler Electric BE156240CAA007 16.5VAC 40VA 1.5A typ: 600mA, max: 700mA Do not exceed 200mA for UL installations 350mA/700mA 2.4 Backup Battery To provide power during a power loss, connect a 12Vdc 4Ah rechargeable acid/lead or gel cell backup battery as shown in Figure 1 on page 2. Use a 7Ah battery to comply with UL fire requirements. Connect the backup battery after applying AC power. When installing, verify proper polarity as reversed connections will blow the battery fuse. Also, refer to Battery Charge Current on page 36. 2.4.1 Battery Test If the battery is disconnected or if the battery fuse is blown, a No/Low Battery failure will appear in the keypads trouble display (see page 42). This trouble will also appear if the batterys capacity is too low or if the voltage drops to 10.5V or lower while the control panel is running on the backup battery. At 8.5V or lower, the panel shuts down and all outputs close. Figure 1: AC Power and Backup Battery Connections Partial view of Spectra 1759MG control panel UL Warning:
A 12Vdc / 7Ah battery is required to comply with UL fire requirements. Caution:
Disconnect battery before replacing the fuse. Improper connection of the transformer may result in damage to the system. Rechargeable Battery UL/ULC - 12Vdc / 4Ah or 7Ah 2 Reference & Installation Manual Figure 2: Spectra 1759MG Control Panel Overview STATUS LED:
Flash once every second = normal ON 1 second and OFF 1 second = trouble Always ON = panel is using phone line Fast flash 4 seconds after power up = installer lock enabled RX LED:
Flashes quickly when receiving signals from wireless devices. Antennae Paradox Memory Key (PMC-3) Reset Jumper Refer to AC Power and Backup Battery Connections on page 2. Four pin connector can be used for the quick installation of a Spectra keypad or Expansion Module. To connect the 5A Alarm Relay and the PGMs, refer to Relay and PGM Connections on page 5. To connect AC power, refer to AC Power and Backup Battery Connections on page 2. Refer to Single Zone Inputs on page 5. Warning: Do not cut, bend or alter the antennae &
ensure that electrical wires do not cross over the antennae as these may affect the signal reception. Warning:
Disconnect telephone line before servicing. AWG#14 single conductor solid copper wire Cold water pipe grounding Ground clamp The BELL output will shut down if the current exceeds 3A. Communication Bus AUX Power Refer to Transformer Requirements Table on page 2 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. For the keypads zone, EOL and tamper configurations, refer to Configuring The LED Keypad on page 8. To provide maximum lightning protection, we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure The maximum number of keypads per installation is dependent on the auxiliary output, which cannot exceed 700mA. Spectra Keypads A door contact or any other detection device can be connected to the Keypad Zone. Warning: Do not connect keypads more than 76m
(250ft) from the control panel. For UL Listed Warnings, refer to UL AND ULC WARNINGS on page 48. Spectra 1759MG 3 2.5 Auxiliary Power Terminals*
The auxiliary power supply terminals can be used to power motion detectors, keypads and other modules or accessories in the security system. A fuseless circuit protects the power supply against current overload and automatically shuts down if the current exceeds 1.1A. If this occurs, the Maximum Auxiliary Current failure will appear in the keypads trouble display (see page 42). Therefore, the combined current consumption of devices connected to the auxiliary power supply should not exceed 700mA. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. Modules with the APR- prefix are compatible with the Spectra 1759MG and DGP-848. Modules with the APR3- prefix are compatible with the Spectra 1759MG, DGP-848 and DGP-NE96. Table 2: Current Consumption Table Modules Spectra 1686H and 1686V 10-Zone LED Keypad Spectra 1689 16-Zone LED Keypad Spectra 1641 LCD Keypad 4-Zone Hardwire Modules (APR3-ZX4/SPC-ZX4) 8-Zone Hardwire Modules (APR3-ZX8/SPC-ZX8) 4-PGM Output Module (APR3-PGM4) Printer Module (APR3-PRT1) InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2) Motion Detectors (see detector instructions for details) Current Consumption Maximum 116mA 117mA 80mA 12mA 30mA 150mA 40mA 105mA Typical 62mA 50mA 60mA 12mA 30mA 13mA 22mA 70mA 10 to 50mA 2.6 2.7 Telephone Line Connection In order to report system events to the monitoring station, you must connect the incoming telephone company wires into the TIP and RING connections of the control panel and then run the wires from T1 and R1 to the telephone or telephone system as shown in Figure 2 on page 3. Bell Output Connection The BELL+ and BELL- terminals power bells, sirens and other warning devices requiring a steady voltage output during an alarm. The bell output supplies 12Vdc upon alarm and can support one 30-watt or two 20-watt sirens. The bell output uses a fuseless circuit and will automatically shut down if the current exceeds 3A. When this occurs the Maximum Bell Current failure will only appear in the keypads trouble display (see page 42) during an alarm. If the load on the BELL terminals returns to normal, the control panel will re-instate power to the BELL terminals during the next alarm. When connecting sirens, please verify correct polarity. Connect the positive lead to the BELL+ terminal and the negative lead to the BELL- terminal of the control panel as shown in Figure 2 on page 3. If the BELL output is not being used, the Bell Disconnected failure will remain in the keypads trouble display
(see page 42). To avoid this connect a 1K resistor across the BELL terminals. 2.8 Programmable Output Connections*
When a specific event occurs in the system, a PGM can reset smoke detectors, activate strobe lights, open/close garage doors and much more. 2.8.1 Alarm Relay and PGMs The Spectra 1759MG control panel includes two on-board programmable outputs (PGMs). For details on how to program the PGM, refer to PGM Programming on page 34. PGM1 can support up to 150mA while PGM2 supports up to 1A (see Figure 3 on page 5) and can be used as a strobe output (see page 35). The PGMs are limited by the power source being used. If powered by:
The AUX terminals. The current consumption of the AUX terminals cannot exceed 700mA. Therefore, whatever devices are connected to the AUX terminals (i.e. modules and PGMs) cannot exceed 700mA combined. For example, if there are six modules connected to the AUX terminals that are using 600mA and you wish to power the PGM using the AUX terminals, the PGMs current consumption cannot exceed 100mA. An external power supply. If using an external power supply, the current consumption cannot exceed 150mA for PGM1 and 1A for PGM2. If the external power supplys current consumption limit is less than that of the PGM it is connected to, than the current consumption will not exceed the power supplys current limit. The Spectra 1759MG control panel also has a 5A relay. This relay can be connected as shown in Figure 3 on page 5. The Alarm Relay can be programmed to follow the bell output or the activation and deactivation of the Global PGM
(see Alarm Relay Options on page 35).
* UL Note: The AUX and PGM terminals cannot exceed 200mA for UL installations. 4 Reference & Installation Manual Figure 3: Relay and PGM Connections AUX+ or External Power Supply. See Programmable Output Connections* on page 4. Alarm Relay (5A) can be programmed to follow the BELL output or the Global PGM. External Power Supply Any device such as a strobe light or siren 2.9 Single Zone Inputs Detection devices such as motion detectors and door contacts are connected to the control panel's zone input terminals. Figure 4 demonstrates single zone input terminal connections recognized by Spectra. Once connected, the associated zone's parameters must be defined. For details refer to Zone Programming on page 12. Figure 4: Single Zone Input Connections 2.10 Keypad and Keypad Zone Connections To connect the keypads to the control panel, remove the back cover and wire the GRN, YEL, RED, and BLK terminals of each keypad to the corresponding terminals on the control panel as shown in Figure 2 on page 3. There is no limit to the number of keypads that can be connected to the control panel as long as the current consumption does not surpass 700mA*. See Keypad Tamper Supervision on page 37. Each keypad has one zone input terminal, allowing you to connect one motion detector or door contact directly to a keypad. The
* UL Note: Cannot exceed 200mA for UL installations. Spectra 1759MG 5 keypad can then communicate the status of the zone to the control panel. A maximum of two keypad zones can be used with each control panel. After connecting the device, the zone's parameters must be defined. For details on zone recognition and Zone Programming on page 12. Also, refer to the feature Reassign Keypad Zone 2 on page 12. Example: A door contact located at the entry point of an establishment can be wired directly to the input terminal of the entry point keypad instead of wiring the door contact all the way to the control panel. Figure 5: Keypad Zone Connections Do not place a jumper across the zone and BLK input terminals of the keypads that are not using their keypad zones. 1641 LCD Keypad
(Not using keypad zone) Be sure to enable option [1] (Keypad Zone Sending) of option [2] (Options) in the 1641s LCD Programming Mode. 2.11 2.12 A door contact or any other detection device 1686H
(Using keypad zone) 1686H
(Not using keypad zone) When a 1641 LCD keypad is connected to the 1759MG, the Keypad Zone Sending option (Option [2] key [1]) determines whether the status of the keypad zone will be transmitted to the control panel. The Keypad Zone Sending option of the 1641 keypad must be enabled during the following conditions:
If you are using both keypad zones and at least one is from a 1641 keypad. If you are using the keypad zones of other types of keypads, such as a 1686H 10-zone LED keypad, and the keypad zone definition of the 1641 keypad (keypad zone 1 or keypad zone 2; Option [2] key [3]) matches that of another connected keypad. Keyswitch Connections Keyswitches allow users to arm or disarm a partition by pushing a button or by activating a switch with a key. Connect the keyswitch (as shown in Figure 6) directly to the control panel terminals. Once a keyswitch is connected, it must be assigned to a zone and its parameters must be programmed (see Zone Programming on page 12 and Keyswitch Options on page 17). Figure 6: Keyswitch Fire Circuits When a zone is programmed as a fire zone, the zone becomes normally open and requires an EOL resistor. If a line short occurs or if the smoke detector becomes active, whether the system is armed or disarmed, the control panel will generate an alarm. If a trouble occurs on a fire zone, the Fire Loop Trouble will appear in the keypads trouble display (see page 42) and the control panel can transmit the Fire Loop Trouble report, if programmed, in section [206]. 2.12.1 4-Wire Installation:
Any on-board zone can be defined as a fire zone (see page 13) when using the 4-
wire installation. Connect the smoke detectors (as shown in Figure 7) directly to the control panel terminals. Program the PGM with the [PG]/[FNC1] Key was Pressed Activation Event (see page 34) so the smoke detectors can be reset by pressing the
[PG] or [FNC1] key. Pressing the [PG] or [FNC1] key will interrupt power to the smoke detectors for 4 seconds (see PGM Delay on page 35). Figure 7: Fire Zones It is recommended that all smoke detectors be connected using a daisy chain configuration. 6 Reference & Installation Manual Part 3: Programming Methods 3.1 3.2 WinLoad Software for Windows*
Program the Spectra Series control panels remotely or on-site using the Winload Software for Windows. For more information, contact your local Paradox Distributor or visit our web site at www.paradox.ca. If you are using the WinLoad software, you must program the features explained on pages 40 and 41.
* Not investigated by UL. Programming Using a Keypad Use the supplied Spectra 1759MG Programming Guide to keep track of which sections were programmed and how. We recommend you read this entire manual before you begin programming. How Do I Enter Programming Mode?
1) Press [ENTER]
2) Enter your [INSTALLER CODE] (default: 0000 / 000000) 3) Enter 3-digit [SECTION] you wish to program 4) Enter required [DATA]
3.2.1 Single Digit Data Entry Method (Hexadecimal and Decimal) Single Digit Data Entry is used in all sections except those specified in the Feature Select Programming Method
(below). After entering Programming Mode as described in the shaded box above, some sections will require that you enter Decimal values from 000 to 255. Other sections will require that you enter Hexadecimal values from 0 to F. The required data will be clearly indicated in this manual as well as in the Spectra 1759MG Programming Guide. When entering the final digit in a section, the control panel will automatically save and advance to the next section. Except sections 001 to 016, after entering the first two digits the control panel will switch to Feature Select Programming. Table 3: Decimal and Hexadecimal Programming Table Value or Action What Do I Press?
Values 1 to 9 A (hexa only) B (hexa only) C (hexa only) D (hexa only) E (hexa only) F (hexa only) Exit Without Saving Insert Blank Digit Save Data
[1] to [9]
[0]
[STAY]
[BYP]
[MEM]
[TBL] / [TRBL]
[PG] / [FNC1]
[CLEAR]
[FORCE]
[ENTER]
10-Zone LED
[1] to [9]
[0 (10)]
[STAY]
[BYP]
[MEM]
[TBL]
[PG]
What Do I See?
16-Zone LED
[1] to [9]
[10]
[11]
[12]
[13]
[14]
[15]
LCD
[1] to [9]
0 B C D E F
[ARM1] & [STAY1] flash
[ENTER] flashes Displays next digit or next section Advances to the next section SECTION [ ]
3.2.2 3.2.3 Feature Select Programming Method After entering sections [001] to [016], [126] to [138], and [302] to [348], each option from [1] to [8] represents a specific feature or option. Press the key corresponding to the desired option and the corresponding light will illuminate or the option number will appear in the LCD display. This means the option is on. Press the key again to extinguish the corresponding light or remove the digit from the LCD display, thereby, turning off the option. Press the [FORCE] key to set all 8 options to off. Press the keys until the current sections options are set. When the options are set, press the
[ENTER] key to save and advance to the next section. Data Display Mode (LED Keypads Only) In the Data Display Mode you can view the programmed contents of each section one digit at a time. After entering the desired 3-digit section (see step 3 of the shaded box on page 7), press the [ENTER] key to access the Data Display Mode (will not function with sections using Multiple Feature Select Programming). Spectra 1759MG 7 Figure 8: Data Display Mode (LED Keypads Only) To access the Data Display Mode, press the [ENTER] key after entering a section and before entering any data. The three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode. 1686H 1686V 1689 Each time the [ENTER] key is pressed, the keypad will display the next digit in the current section and will continue through all the following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature Select Method. Press the [CLEAR] key at any time to exit the Data Display Mode. 3.3 Configuring The LED Keypad Depending on the version of the keypad, two methods can be used to configure the LED keypad (1686H, 1686V and 1689):
3.3.1 Configuring the 1686H, 1686V and 1689 Keypad V2.0 or higher The keypads zone number, EOL definition and anti-tamper switch are programmed through the control panels programming mode. To do so:
How Do I Configure The Keypad?
1) Press [ENTER]. 2) Enter your [INSTALLER CODE] (default: 0000 / 000000). 3) Press the [PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds. 4) Press the desired key ([1] to [3]. See below). 5) Press [ENTER] to exit programming mode. PLEASE NOTE: After two minutes, the keypad exits programming mode. Key [1] - Keypad Zone Selection Key [1] determines whether the keypads zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF (not illuminated), the keypads zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypads zone is Keypad Zone 2. Refer to the Table 4 on page 12 for more information. Key [1] OFF - Keypad Zone 1 (default) Key [1] ON - Keypad Zone 2 Key [2] - EOL Definition Key [2] determines the keypad zones EOL definition. When key [2] is OFF (not illuminated), EOL is disabled and the keypad zone will use the on-board EOL resistor. When key [2] is ON (illuminated), EOL is enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra 1759MG Control Panel Overview on page 3 for more details). Key [2] OFF - EOL disabled Key [2] ON - EOL enabled (default) Key [3] - On-Board Anti-Tamper Key [3] enables or disables the keypads on-board anti-tamper switch. When key [3] is OFF (not illuminated), the anti-
tamper switch is disabled. When key [3] is ON (illuminated), the anti-tamper switch is enabled. Key [3] OFF - On-board anti-tamper switch disabled Key [3] ON - On-board anti-tamper switch enabled 8 Reference & Installation Manual NOTE: The keypad can be ordered with or without an anti-tamper switch. If the keypad has no anti-
tamper switch, key [3] will be OFF by default. If the keypad has an anti-tamper switch, key [3] will be ON by default. 3.4 Programming Using A Paradox Memory Key*
Copy the sections of one Spectra control panel into the Paradox Memory Key (PMC-3). Then copy the contents of the Memory Key into as many Spectra control panels as needed. Each panel is programmed in less than 3 seconds. Download to DESTINATION Control Panel 1) Remove AC and battery power from the control panel. 2) Place the Memory Key on the serial connector labeled KEY of the Spectra Control Panel that is to receive the contents of the Memory Key. In Installer Programming Mode, enter section [900], then press [ENTER] to acknowledge. 3) Reapply AC and battery power. 4) 5) When the keypad emits a confirmation beep, remove the Memory Key. 6) Enter section [750] to reprogram the modules with the information downloaded from the Paradox Memory Key. Copy to Memory Key from SOURCE Control Panel 1) Remove AC and battery power from the control panel. 2) Place Memory Key on the serial connector labeled KEY of the Spectra Control Panel that you want to copy. Make sure the write protect jumper of the Memory Key is on. 3) Reapply AC and battery power. 4) 5) When the keypad emits a confirmation beep, remove the Memory Key. Remove the Memory In Installer Programming Mode, enter section [902], then press [ENTER] to acknowledge. Keys jumper if you do not wish to accidentally overwrite its contents. Figure 9: Paradox Memory Key Jumper ON =
Read from and/or write to memory key. Paradox Memory Key PMC-3 Jumper OFF =
Write protected (read from memory key only) Insert Paradox Memory Key onto the MEMORY KEY connector. Partial view of Spectra 1759MG control panel
* Not investigated by UL Spectra 1759MG 9 The Spectra 1759MG control panel supports the following access codes:
Part 4: Access Codes 4.1 4.2 4.3 4.4 Installer Code:
System Master Code (001):
Master Code 1 (002):
Master Code 2 (003):
45 User Codes (004 to 048):
Used to program all control panel settings except user access codes. Provides full access. Arm and disarm using any method described in the User Code Options on page 10 as well as program the user access codes. Permanently assigned to partition 1. Same as a regular user code except it can also program access codes for user codes assigned to partition 1. Permanently assigned to partition 2. Same as a regular user code except it can program access codes for user codes assigned to partition 2. If the system is not partitioned Master Code 002 will be assigned to partition 1. Can arm and disarm as per User Code Options on page 10. Access Code Length Section [127]: System Options Option [2] OFF = 6-Digit Access Codes Option [2] ON = 4-Digit Access Codes (default) All access codes can be set to lengths of either 4- or 6-digits. When the 4-digit option is selected, entering a 4-digit code will allow access. Using the 6-digit option, entering 6 digits is required to allow access. If the access code length is changed from four digits to six digits when access codes have already been programmed, the control panel will automatically add the last 2 digits by using the first 2 digits. For example, if the access code is 1234 and you switch to 6 digits, the code will become 123412. Be sure to verify the access codes after switching from 4-digit access codes to 6-digit codes. When switching from six digits to four digits, the control panel will simply remove the final two digits of the access code. For example, 123456 will become 1234. Installer Code (Default: 0000 / 000000) The Installer Code is used to enter the 1759MGs programming mode (see page 7), which allows you to program all the features, options and commands of the control panel. The Installer Code can be 4- or 6-digits in length (see Access Code Length on page 10) where each digit can be any value from 0 to 9. The Installer Code cannot be used to program Master Code 1, Master Code 2 or user access codes. To program the Installer Code press:
[ENTER] + [CURRENT INSTALLER CODE] + [281] + new 4- or 6-digit Installer Code System Master Code (Default: 1234 / 123456) The Installer Code can be used to program the System Master Code. With the System Master Code a user can use any arming method and can program any user access code, but not the User Code Options. The System Master Code can be 4 or 6 digits in length Access Code Length on page 10, where each digit can be any digit from 0 to 9. To change the System Master Code press:
[ENTER] + [INSTALLER CODE] + [301] + new 4- or 6-digit System Master Code User Code Options Sections [302] to [348]: Options [1] to [7]
The User Code Options define which arming methods each user can use to arm or disarm the system. Regardless of these settings, all users can Regular arm assigned partitions and all users except those with the Arm Only option can disarm an assigned partition, regardless of how it is armed. Select one or more of the options described on the following pages for each user access code, where sections [302] to [348] represent user access codes 002 to 048. For more information please refer to Programming Access Codes on page 43. 4.4.1 Partition 1 Assignment Sections [302] to [348]: User codes 002 to 048 Option [1] OFF = Deny access to partition 1 Option [1] ON = User code has access to partition 1 (default) If the system is partitioned (see page 36), user codes with this option enabled can arm and disarm partition 1. If the system is not partitioned, you must assign partition 1 to the user access code. Otherwise, the user access code will be considered disabled. 10 Reference & Installation Manual 4.4.2 4.4.3 4.4.4 4.4.5 4.4.6 4.4.7 Partition 2 Assignment Sections [302] to [348]: User Codes 002 to 048 Option [2] OFF = Deny access to partition 2 (default) Option [2] ON = User code has access to partition 2 If the system is partitioned (see Partitioning on page 36), user codes with this option enabled can arm and disarm partition 2. If the system is not partitioned, the control panel ignores this option. Bypass Programming Sections [302] to [348]: User Codes 002 to 048 Option [3] OFF = Bypass Programming Disabled Option [3] ON User codes with this option enabled can perform Bypass Programming in assigned partitions.
= Bypass Programming Enabled (default) Stay Arming Sections [302] to [348]: User Codes 002 to 048 Option [4] OFF = Stay Arming Disabled Option [4] ON = Stay Arming Enabled for selected User Code (default) User codes with this option enabled can Stay arm assigned partitions. Force Arming Sections [302] to [348]: User Codes 002 to 048 Option [5] OFF = Force Arming Disabled (default) Option [5] ON = Force Arming Enabled for selected User Code User codes with this option enabled can Force arm assigned partitions. Arm Only Sections [302] to [348]: User Codes 002 to 048 Option [6] OFF = Arm Only Disabled (default) Option [6] ON = Arm Only Enabled for selected User Code The user code with this option enabled can arm assigned partitions, but cannot disarm any partitions. The type of arming is dependent on the other User Code Options selected. Please note that with the Arm Only option, the user can cancel a recently armed system by re-entering the access code before the end of the exit delay. PGM Activation Sections [302] to [348]: User Codes 002 to 048 Option [7] OFF = User Code follows User Code Options and can activate a PGM (default) Option [7] ON = User Code can activate a PGM only With option [7] off, entering the access code will arm or disarm according to the programmed User Code Options as well as activate or deactivate a PGM. The appropriate PGM Activation/Deactivation Event must also be programmed
(see Programmable Outputs on page 34). With option [7] on, the control panel will ignore all other User Code Options. Therefore, entering the access code will only activate or deactivate the PGM. 4.5 4.6 Lock Master Code Section [127]: System Options Option [4] OFF = Lock System Master Code Disabled (default) Option [4] ON = Lock System Master Code Enabled With this feature enabled, the control panel will lock the System Master Code (001). This means that the System Master Code cannot be deleted, but it can be changed. Duress Code Section [127] = System Options Option [6] OFF = Duress Code Disabled (default) Option [6] ON = User Code 048 becomes a Duress code With this feature enabled, User Code 048 becomes a Duress Code. When forced to arm or disarm their system, users can enter a Duress Code (User Code 048) to arm or disarm the system which can immediately transmit a silent alert to the monitoring station, transmitting the duress report code programmed in section [196]. Spectra 1759MG 11 Part 5: Zone Programming When programming zones, the zone assignments are dependent on where the detection devices are connected to in the system (see Table 4). In installations that require using mostly the expansion inputs (see section 5.1), refer to Reassign Keypad Zone 2 on page 12 and Reassign Zones to Expansion Inputs on page 13. Table 4: Zone Recognition Table Option [7]: OFF Option [8]: OFF Option [7]: ON Option [8]: OFF Option [7]: OFF Option [8]: ON Option [7]: ON Option [8]: ON Control Panel Input 1 =
Input 2 =
Input 3 =
Input 4 =
Input 5 =
Keypad Zone 1 =
Zone 2 =
Expansion Input 1 =
Input 2 =
Input 3 =
Input 4 =
Input 5 =
Input 6 =
Input 7 =
Input 8 =
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 N/A Zone 7 Zone 8 Zone 9 Zone10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 1 Zone 2 N/A N/A N/A Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 1 Zone 2 N/A N/A N/A Zone 3 N/A Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11
= not displayed on 10-Zone LED Keypads Option [7] = Reassign Keypad Zone 2 Option [8] = Reassign Zones to Expansion Inputs 5.1 5.2 What is an Expansion Input?
An expansion input allows you to connect modules to the system to increase the number of zones available up to 15 zones. Each hardwired input on a zone expansion bus module or wireless transmitter can be assigned to an expansion input. The expansion inputs can be used in any combination. For example, 5 wireless transmitters and 3 hardwire inputs can be assigned to the expansion inputs. Spectra control panels cannot support more than eight expansion inputs. Refer to the appropriate modules Instruction Sheet for details. Do not assign inputs from different modules to the same expansion input. Reassign Keypad Zone 2 Section [126]: General Options Option [7] OFF = Reassign Keypad Zone 2 Disabled (default) Option [7] ON = Reassign Keypad Zone 2 Enabled In installations that require using mostly the expansion inputs, such as using wireless zones, 10-Zone LED keypads may be unable to display some of the zones. The Reassign Keypad Zone 2 feature changes the zone numbering to increase the number of expansion inputs that are displayed on 10-Zone LED keypads. Combine with the Reassign Zones to Expansion Inputs feature
(see page 13) to increase the number of displayable expansion inputs. See Table 4 for Zone Recognition. When Reassign Keypad Zone 2 is enabled, the Keypad Tamper Supervision (see page 37) for Keypad Zone 2 is lost. Keypad Tamper Supervision will ONLY function on Keypad Zone 1. 12 Reference & Installation Manual 5.3 5.4 Reassign Zones to Expansion Inputs Section [126]: General Options Option [8] OFF = Reassign Zones to Expansion Inputs Disabled (default) Option [8] ON = Reassign Zones to Expansion Inputs Enabled In installations that require using mostly the expansion inputs, such as using wireless zones, 10-Zone LED keypads may be unable to display some of the zones. The Reassign Zones to Expansion Inputs feature changes the zone numbering to increase the number of expansion inputs that are displayed on 10-Zone LED keypads. Combine with the Reassign Keypad Zone 2 feature
(refer to Reassign Keypad Zone 2 on page 12) to increase the number of displayable expansion inputs. See Table 4 on page 12 for the Zone Recognition. Zone Programming After connecting a hardwired detection device to one of the control panel's or zone expansion bus modules input terminals or after setting up any wireless transmitters, define the associated zone's parameters. The zone parameters define the type of zone, the zone's partition assignment and how the control panel will react when an alarm condition occurs on that zone. These zone parameters are programmed into one section as detailed in Figure 10 on page 13. See Table 4 on page 12 for the Zone Number Recognition. Only the control panels on-board inputs can be defined as a fire, delayed fire or a keyswitch zone. The on-board zones are zones 01 to 05. Figure 10: Spectra Zone Programming Zone Definitions 1 - Entry Delay 1 2 - Entry Delay 2 3 - Follow 4 - Instant 5 - 24Hr Burglary 6 - 24Hr Buzzer Additional definitions for on-board terminals:
7 - Keyswitch 8 - 24Hr Fire 9 - 24Hr Delayed Fire Press the
[ENTER] key Enter the
[INSTALLER CODE]
Key in 3-digit
[SECTION]
[001] = Zone 1
[002] = Zone 2
[003] = Zone 3
[004] = Zone 4
[005] = Zone 5
[006] = Zone 6
[007] = Zone 7
[008] = Zone 8
[009] = Zone 9
[010] = Zone 10
[011] = Zone 11
[012] = Zone 12
[013] = Zone 13
[014] = Zone 14
[015] = Zone 15 Zone Partition Assignment 1 - Zone Assigned to Partition 1 2 - Zone Assigned to Partition 2 3 - Zone Assigned to both Partitions Select one Zone Definition First Digit Select one Zone Partition Assignment Second Digit Keypads beep twice Zone Options Feature Select Press [ENTER]
Zone Options
[5]
Zone Alarm Type
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled
[3] Stay Zone
[4]
OFF OFF Audible Alarm (steady) OFF ON Audible Alarm (pulsed) ON OFF Silent Alarm ON ON Generates only a report
[6] Intellizone
[7] Delay alarm transmission
[8] Force Zone Keyswitch Options
[1] OFF= Maintained ON = Momentary
[2] OFF = Regular Arm ON = Stay Arm 5.5 Zone Definitions As demonstrated in Figure 10, sections [001] to [015] represent zones 1 through 15 respectively, where the first digit in each of these sections represents the zone's definition. Also, refer to Zone Speed on page 17. To disable a zone, clear the contents of the section corresponding to the desired zone by pressing the [FORCE] key 3 times and pressing [ENTER]. There are 9 available Zone Definitions, which are described as follows. Spectra 1759MG 13 5.5.1 5.5.2 5.5.3 5.5.4 5.5.5 5.5.6 Entry Delay 1 Sections [001] to [015]: Zones 1 to 15, First Digit = 1 When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an alarm after the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45 seconds) into section [069]. Entry delay zones are commonly used at the entry/exit points of the protected area (i.e. front/back door, garage, etc.). Using different entry delays (see Entry Delay 2 on page 14) is useful when, for example, one entry point requires a longer delay than the other entry point or in a partitioned system where each partition may require a different entry delay. Entry Delay 2 Sections [001] to [015]: Zones 1 to 15, First Digit = 2 Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate entry delay timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45 seconds) into section [070]. This timer is also used as the Stay Delay timer (see Stay Arming with Delay on page 22). Follow Zones Sections [001] to [015]: Zones 1 to 15, First Digit = 3 When an armed Follow Zone opens, the control panel will immediately generate an alarm, unless an entry delay zone opens first:
If an armed Follow Zone opens after an entry delay zone opens, the control panel waits until the entry delay timer has elapsed before generating an alarm. If an armed Follow Zone opens after more than one entry delay zone opens, the control panel will wait until the entry delay timer of the zone that opened first has elapsed. This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the system. Instant Zones Sections [001] to [015]: Zones 1 to 15, First Digit = 4 When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are commonly used for windows, patio doors, skylights and other perimeter type zones. 24Hr Burglary Zones Sections [001] to [015]: Zones 1 to 15, First Digit = 5 Whenever a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will immediately generate an alarm. 24Hr Buzzer Sections [001] to [015]: Zones 1 to 15, First Digit = 6 Whenever a 24Hr Buzzer Zone opens, whether the zone is armed or disarmed, the control panel sets off the keypads buzzers to indicate that the zone was breached. The control panel will report the alarm, but will not enable the bell/
siren output. Enter any valid access code on the keypad to stop the buzzer. This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed
(i.e. a child accessing a valuable collection). 5.6 Exclusive Zone Definitions The following three zone definitions can only be used for devices connected directly to the control panels on-board input terminals. When a zone is programmed as a keyswitch zone, the control panel will ignore all other Zone Options. When a zone is programmed as a standard fire zone or delayed fire zone, the control panel will ignore the Zone Options that may have been programmed, except Auto Zone Shutdown. Wireless devices and devices connected to the zone expansion bus modules cannot be programmed with these definitions. 5.6.1 Keyswitch Zone Sections [001] to [005]: Zones 1 to 5, First Digit = 7 Connecting a keyswitch to a zone allows users to arm the system by pressing a button or by turning a switch on or off with a key. Please refer to Keyswitch Connections on page 6 and Keyswitch Options on page 17. 14 Reference & Installation Manual 5.6.2 Standard 24Hr Fire Zone Sections [001] to [005]: Zones 1 to 5, First Digit = 8 Whenever a Standard 24Hr Fire Zone opens, whether it is armed or disarmed, the control panel will generate the following:
The control panel can send the corresponding Alarm report code from sections [187] to [190]. If a tamper/wiring fault occurs on a fire zone, the control panel can send a Fire Loop Trouble report code programmed in section [206] to the monitoring station. The keypad will display a Fire Loop Trouble in its trouble display (see page 42). Alarms are always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 11 on page 15. For information on how to connect smoke detectors to the control panel, refer to Fire Circuits on page 6. 5.6.3 Delayed Fire Zone Sections [001] to [005]: Zones 1 to 5, First Digit = 9 When a Delayed 24Hr Fire Zone opens, whether it is armed or disarmed, the control panel will react as shown in Figure 12 on page 15. Delayed 24Hr Fire Zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e. burning bread, etc.). Figure 11: Bell Output During Fire Alarm Figure 12: Delayed 24Hr Fire Zone Bell Output Fire Alarm Latched On Off 0.5s 0.5s 1.5s 5.7 Programming a Wireless Fire Zone Fire zones cannot be assigned to expansion zones. As a result, when installing a wireless smoke detector, the corresponding zone must be programmed as follows:
How Do I Program a Wireless Fire Zone?
1) Enter [5] in the Zone Definition to define it as a 24Hr Burglary Alarm (see page 14). 2) Disable [4] and enable [5] in Zone Options to set the zones alarm type to a pulsed Audible Alarm (see Figure 10 on page 13). 3) Disable [1] and [2] in Zone Options to disable the zones Auto Zone Shutdown and Bypass Enabled features (see Figure 10 on page 13). 4) Change the zones report code from a Burglary report code (Prog. Value 11) to a Fire report code (Prog. Value 04). If using Ademco Contact I.D., set the Contact ID Options from All Codes to Programmable (section [136] option [3] = OFF) and then enter the report code manually. See Spectra 1759MG Programming Guide for more information. 5.8 Zone Partition Assignment Sections [001] to [015]: Zones 1 to 15 The control panel provides the option of partitioning the security system into two completely independent systems. As demonstrated in Figure 10 on page 13, sections [001] to [015] represent zones 1 through 15 respectively, where the second digit in each of these sections represents the zone's partition assignment. The zone is assigned to Partition 1 if second digit = 1, Partition 2 if second digit = 2, or both partitions is second digit = 3. For more details, refer to Partitioning on page 36. Spectra 1759MG 15 5.9 Zone Options As demonstrated in Figure 10 on page 13, sections [001] to [015] represent zones 1 through 15 respectively. After entering the first two digits, select one or more of the following Zone Options by using the Multiple Feature Select Programming Method (see page 7):
5.9.1 Auto Zone Shutdown Sections [001] to [015] = Zones 1 to 15 Option [1] OFF = Auto Zone Shutdown Disabled Option [1] ON = Auto Zone Shutdown Enabled for selected zone (default) 5.9.2 5.9.3 5.9.4 5.9.5 If, in a single armed period, the number of alarms generated by a zone with the Auto Zone Shutdown option enabled exceeds the number defined by the Auto Zone Shutdown Counter, the control panel will no longer generate an alarm for that zone. To program the Auto Zone Shutdown Counter, key in the desired limit (000=Disabled, 001 to 015, Default
= 5) into section [089]. The Auto Zone Shutdown Counter resets every time the partition that is assigned to the corresponding zone is armed. Bypass Zones Sections [001] to [015] = Zones 1 to 15 Option [2] OFF = Bypass Zone Disabled Option [2] ON = Selected Zone is Bypass Enabled (default) When a user utilizes the Bypass Programming feature (see page 44), only zones with the Bypass option enabled can be programmed as bypassed. Do not program a fire zone with the Bypass option, as the control panel will never bypass fire zones. Stay Zones Sections [001] to [015]: Zones 1 to 15 Option [3] OFF = Stay Zone Disabled (default) Option [3] ON = Selected Zone is Stay Enabled Zones with the Stay option enabled will be bypassed when the system is Stay Armed (see page 44). Do not program a fire zone with the Stay option, as the control panel will never bypass fire zones when Stay arming. Alarm Types Sections [001] to [015]: Zones 1 to 15
[4] OFF / [5] OFF: Audible Steady (default) When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and provides a steady output for any bells or sirens connected to the control panels bell output.
[4] OFF / [5] ON: Audible Pulsed Alarm When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and provides a pulsed output (see Figure 11 on page 15) for any bells or sirens connected to the control panels bell output.
[4] ON / [5] OFF: Silent Alarm When the conditions for an alarm are met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and will not activate the control panels bell output. The appropriate ARM or STATUS LED on the keypads will flash to indicate an alarm and the user will still have to disarm the system.
[4] ON / [5] ON: Report Only When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28). The system will not have to be disarmed. Intellizone Sections [001] to [015]: Zones 1 to 15 Option [6] OFF = Intellizone Disabled (default) Option [6] ON = Intellizone Enabled for Selected Zone This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the panel does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. To program the Intellizone Delay Timer, key in the desired 3-digit value (010 to 255 seconds, Default = 48 seconds) into section [084]. If any of the following conditions occur during this period, the panel will generate an alarm:
During the Intellizone Delay, a second zone has caused an alarm. During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened). The zone in alarm remains open for the entire Intellizone Delay. 16 Reference & Installation Manual 5.9.6 5.9.7 5.9.8 Delay Before Alarm Report Code Transmission Sections [001] to [015]: Zones 1 to 15 Option [7] OFF = Delay Alarm Transmission Disabled (default) Option [7] ON = Delay Alarm Transmission Enabled for Selected Zone When an alarm condition occurs on a zone with this option enabled, the control panel enables the bell/siren output, but does not report the alarm to the monitoring station until the end of the Alarm Before Transmission Delay. To program the Alarm Transmission Delay, key in the desired 3-digit delay value (000 = Disabled, 001 to 255 seconds) into section
[080]. During this period, disarming the system disables the bell/siren output and cancels the report code transmission. This feature is commonly used with entry delay zones to reduce false alarms created by new users who may not disarm the system in time. Force Zones Sections [001] to [015]: Zones 1 to 15 Option [8] OFF = Force Zone Disabled (default) Option [8] ON = Selected Zone is Force Enabled Any open Force Zones at the time of arming will be considered deactivated by the control panel (see page 44). If during this period a deactivated zone is closed, the control panel will revert that zone to active status. Consequently, the control panel will generate an alarm if the zone is breached. Do not program a fire zone with the Force option, as the control panel will never bypass fire zones when Force arming. Keyswitch Options Sections [001] to [005]: Option [1] and [2]
When an on-board zone is programmed as a keyswitch zone (see page 14), the control panel will ignore any other Zone Option. The keyswitch can be programmed as a Maintained or Momentary Keyswitch and to Regular or Stay arm
(see page 44). A Maintained Keyswitch will arm the system when it is set to the ON position and will disarm when set to the OFF position. To arm with a Momentary Keyswitch, set the keyswitch to the ON position then turn it back to the OFF position. Repeating this sequence will disarm the system. Program the keyswitch with the following:
Option [1] OFF Option [1] ON
= Regular Arming (default)
= Stay Arming
= Maintained (default)
= Momentary Option [2] OFF Option [2] ON 5.10 5.11 Zone Speed Sections [050] to [064]: Zones 1 to 15 001 to 255 X 10ms, Default = 600ms The Zone Speed defines how quickly the control panel will respond to an open zone. The control panel will not display an open zone on the keypad or generate an alarm until the programmed Zone Speed has elapsed. All other zone definitions and options do not come into effect until the Zone Speed has elapsed. This feature prevents any momentary glitches from causing an alarm or unnecessary reporting. EOL Zones Section [132]: Zone Options Option [4] OFF = Zones do not use EOL resistors (default) Option [4] ON = Zones require EOL resistors If all detection devices connected to the control panel have input terminals that require 1K end of line resistors, enable option
[4] in section [132]. For details on using EOL resistors, refer to Single Zone Inputs on page 5. Spectra 1759MG 17 Part 6: Wireless Features The Spectra 1759MG allows for the addition of up to eight fully supervised Magellan wireless transmitters, and up to eight programmable remote controls. To program a wireless fire zone, refer to Programming a Wireless Fire Zone on page 15. 6.1 Wireless Transmitter Programming The programming of the wireless transmitters (detectors and door contacts) is accomplished in two steps:
1. Assign the wireless transmitter to the Spectra 1759MG. 2. Program the zones. 6.1.1 Assigning Wireless Transmitters to the Receiver Sections [601] to [608]
Sections [601] to [608] represent expansion inputs 1 to 8 respectively. For example, section [601] is assigned to expansion input 1, section [602] is assigned to expansion input 2, etc. (refer to Table 5). Each Expansion Input represents a specific zone in the Spectra 1759MG system (see Table 4 on page 12). Table 5: Sections and Expansion Inputs Section #
[601]
[602]
[603]
[604]
[605]
[606]
[607]
[608]
6-digit Serial Number ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ ___/___/___/___/___/___ Expansion Input Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 How Do I Assign Wireless Transmitters to the Spectra 1759MG?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [601] to [608]). 4) Enter the 6-digit [SERIAL NUMBER] of the wireless transmitter. Do not assign detection devices from different modules to the same expansion input. For example, do not assign a wireless transmitter to section [601] and then connect a detection device to input Z1 of the APR3-ZX8. The serial number is located on the inside of the transmitter or you can use the Serial Number Display (see page 19) to determine its serial number. The transmitters must be activated once having been assigned to the Spectra 1759MG. To activate a transmitter, insert the batteries and close the cover. To ensure proper synchronization between the control panel and the transmitter, open and close the zone corresponding to the transmitter. 6.1.2 Deleting Assigned Wireless Transmitters Sections [601] to [608]
How Do I Delete Assigned Wireless Transmitters?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [601] to [608]). 4) Press the [0] key six times to clear the serial number. 6.1.3 Programming the Zones The zones allocated to the wireless transmitters must be programmed. Refer to Zone Programming on page 12 for more information. 18 Reference & Installation Manual 6.2 Viewing the Wireless Transmitter Signal Strength Sections [631] to [638]
Once wireless transmitters have been installed and assigned to the Spectra 1759MG, the signal strength of each transmitter can be verified in sections [631] to [638]. Each section represents the signal strength viewer for a specific device. For example, section [631] is the viewer for the device in section [601] and section [638] is the viewer for the device in section [608]. Please note that this feature only works with wireless transmitters assigned to an Expansion Input (zone) as described in Assigning Wireless Transmitters to the Receiver on page 18. A reading of 1 is the weakest and a reading of 8 is the strongest. An average reading of 3 or higher is acceptable. Sometimes moving the transmitter or control panel by a small amount will greatly increase the signal reception. How Do I View a Wireless Transmitters Signal Strength?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [631] to [638]). 4) Press the transmitters anti-tamper switch or open the corresponding zone. 5) On an LED keypad: The keypad will illuminate numbers 1 to 8. On an LCD keypad: The keypad will display numbers from 1 to 8 on the screen. For example, the LCD screen below shows a signal strength reading of 5. After entering the desired section, ignore the first reading as it will not be accurate. You can also use a beep sequence feature to verify a transmitters signal strength. When you press a transmitters anti-tamper switch, beep tones emanating from all the keypads connected to the communication bus will advise you of the transmitters signal strength. How Do I Attain a Wireless Transmitters Signal Strength using the Beep Sequence?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [631] to [638]). 4) Press the transmitters anti-tamper switch or open the corresponding zone. 5) Listen for the beep tones:
If the signal strength is less than 3 = One beep If the signal strength is between 3 and 6 = Two beeps If the signal strength is greater than 6 = Three beeps This feature cannot be used with any remote controls assigned to the control panel. 6.3 Serial Number Display Section [630]
This feature will display the serial number of any wireless transmitter on any Spectra keypad. How Do I View a Transmitters Serial Number?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the section [630]. 4) Press the [0] key six times to clear the serial number. 5) On an LED Keypad: The serial number digits will appear one at a time by illuminating the corresponding LED light. To view the next digit, press the [ENTER] key. On an LCD Keypad: The first three digits of the serial number will appear. Press the [ENTER] key three times to view the next three digits. 6.4 Supervision Options The Supervision Options cannot be used with any remote controls assigned to the control panel. 6.4.1 Check-in Supervision Section [610]: Supervision Options Option [1] OFF = Check-in Supervision disabled (default) Option [1] ON = Check-in Supervision enabled Spectra 1759MG 19 6.4.2 6.4.3 6.4.4 Option [1] enables the Check-in Supervision feature. The Spectra 1759MG waits for each of its assigned wireless transmitters to send a status signal within a specified time period (as programmed in Check-in Supervision Timer Settings on page 20) to confirm their presence and functionality. If a device has not sent a signal within that time period, the Spectra 1759MG can generate a trouble, an alarm, and/or transmit a report code to the monitoring station
(refer to Wireless Transmitter Supervision Options on page 39). Check-in Supervision Timer Settings Section [610]: Supervision Options Option [2] OFF = Check-in supervision interval is every 24 hours (default) Option [2] ON = Check-in supervision interval is every 80 minutes Option [2] defines the time period that the control panel will expect a check-in status signal from its assigned wireless transmitters. For example, if the timer is set to 80 minutes (option [2] = ON), the control panel will expect a check-in status signal to be sent from its assigned wireless transmitters every 80 minutes. If the Spectra 1759MG does not receive a signal from one of its wireless transmitters within the period of time defined here, it can then generate a trouble, an alarm, and/or can transmit a report code to the monitoring station (refer to Wireless Transmitter Supervision Options on page 39). Refer to Check-in Supervision on page 19 for instructions on enabling check-in supervision. Tamper Supervision Section [610]: Supervision Options Option [8] OFF = Tamper Supervision disabled (default) Option [8] ON = Tamper Supervision enabled When the control panel detects a tamper or wire fault on a zone or on an expansion module, the control panel can generate an alarm and/or trouble, unless the Tamper Supervision is disabled. Low Battery Supervision When the battery voltage of a wireless transmitter (motion detector or door contact) drops below a certain value, the Spectra 1759MG will send a low battery report code to the monitoring station, and a trouble will appear in the keypads trouble display. Section [129] option [6] must be enabled in order for Low Battery Supervision to work. For more information, refer to Wireless Transmitter Low Battery Supervision on page 39. 6.5 Remote Control Programming The Spectra 1759MG accepts up to eight fully programmable remote controls. Programming the remote controls is accomplished in three steps:
1) Assign the remote controls to the Spectra 1759MG control panel. 2) Assign the remote controls to user access codes. 3) Program the buttons on the remote controls. 6.5.1 Assigning a Remote Control to the Spectra 1759MG Sections [731] to [738]: Remote Controls 1 to 8 respectively Remote controls are assigned to the module using the Automatic Learning method. How Do I Assign a Remote Control to the Spectra 1759MG?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [731] to [738]). 4) Press and hold any button on the remote control until the confirmation beep sounds (Beep-Beep-Beep-Beep-Beep). If you are having trouble assigning the remote control, the environment may be too noisy. Therefore, we recommend that you assign the remote controls before installing the transmitters. 6.5.2 Deleting Assigned Remote Controls Sections [731] to [738]: Remote Controls 1 to 8 respectively How Do I Delete a Remote Control?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [731] to [738]). 4) Press the [FORCE] button. 20 Reference & Installation Manual 6.5.3 Assigning Remote Controls to User Access Codes Sections [701] to [708]: Remote Controls 1 to 8 respectively Each remote control must be assigned to a user access code. All user access codes are given a user number from 001 to 048. Enter the desired user number in a section from [701] to [708] that represent the remote control assigned in sections [731] to [738] (refer to Assigning a Remote Control to the Spectra 1759MG on page 20). For example, the remote control assigned in section [731] will be assigned to the user access code designated in section [701]. How Do I Assign a Remote Control to a User Access Code?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [701] to [708]). 4) Enter the [USER NUMBER] to be assigned to the remote control (001 to 048). 6.5.4 Programming the Remote Control Buttons Sections [711] to [718]: Remote Controls 1 to 8 respectively Each remote control can be programmed to perform up to 5 different actions. Each digit in sections [711] to [718]
represents a button or combination of buttons (refer to Table 6 on page 21). When a user arms or disarms using the remote control, the control panel will arm or disarm all the areas assigned to the user access code (see Assigning Remote Controls to User Access Codes on page 21). Sections [711] to [718] represent the remote controls assigned to sections [731] to [738] (refer to Assigning a Remote Control to the Spectra 1759MG on page 20). For example, the buttons for the remote control assigned in section [731] will be programmed in section [711]. How Do I Program the Remote Controls Buttons?
1) Press the [ENTER] key. 2) Enter your [INSTALLER CODE]. 3) Enter the desired [SECTION NUMBER] (from sections [711] to [718]). 4) Enter the [HEXADECIMAL VALUE] (0 to D) of the desired button option from Table 7 in the appropriate space (refer to Table 6). If you do not wish to program all the buttons or button combinations, simply press the [ENTER] key at any time to save and exit. The user code assigned to the remote control (refer to Assigning Remote Controls to User Access Codes on page 21) must have the same User Options enabled. For example, if you enable the Force Arming button option, you must enable the appropriate Force Arming user option. Also, if you enable any Panic button options, you must enable the Panic options in the control panel (refer to Keypad Panic Options on page 26). Table 6: Remote Control Button Programming RC#
Section RC Buttons Default: ( 1 5 0 0 0 0 0 0 ) 1 2 3 4 5 6 7 8
[711]
[712]
[713]
[714]
[715]
[716]
[717]
[718]
= These button combinations are not available with the MG-REM1 or MG-RAC1 remote controls and cannot be programmed. Spectra 1759MG 21 Figure 13: Remote Control Button Identification Four button Remote Control Table 7: Button Options
[7] = Regular Arm and Disarm
[FORCE] = Button Disabled
[8] = Generate a Panic 1 Alarm (Police)
[1] = Regular Arm
[9] = Generate a Panic 2 Alarm (Medical)
[2] = Stay Arm
[A] = Generate a Panic 3 Alarm (Fire)
[3] = Instant Arm
[B] = Activates any PGMs that have Event Group #07* as their Activation Event
[4] = Force Arm
[5] = Disarm
[C] = Activates any PGMs that have Event Group #08* as their Activation Event
[6] = Disarm when there is no alarm [D] = Activates any PGMs that have Event Group #09* as their Activation Event
* Event Group #07, #08 and #09 (Button Pressed on Remote) of the Spectra 1759MG PGM Table. For the PGM Table, please refer to the Spectra 1759MG Programming Guide (1759MG-EP). The Panic feature must be enabled in the control panel. Part 7: Arming and Disarming Options 7.1 7.2 Switch To Stay Arming Section [133]: Partition 1, Section [134] = Partition 2 Option [4] OFF = Switch to Stay Arming Disabled (default) Option [4] ON = Switch to Stay Arming Enabled If a user Regular arms a partition, but does not exit through (open and close) an entry delay zone during the exit delay, the control panel can be programmed to switch from Regular arming to Stay arming. Stay Arming with Delay Section [133]: Partition 1, Section [134] = Partition 2 Option [5] OFF = Stay Arming with Delay Disabled (default) Option [5] ON = Stay Arming with Delay Enabled If a partition is Stay armed when this feature is enabled, all the zones in the partition, except 24Hr zones and Stay zones, are associated with the Stay Delay. Therefore, the control panel will not generate an alarm if a zone is breached until the Stay Delay has elapsed. This feature prevents false alarms by allowing users enough time to disarm their system if a zone is accidentally triggered. For example, if a user opens an armed window or crosses an armed detector on the way to the kitchen in the middle of the night, the user will have enough time to disarm the system before the alarm is generated. Each partitions Stay Delay follows the value programmed in Entry Delay Timer 2 in section [070]. 22 Reference & Installation Manual 7.3 7.4 7.5 7.6 7.7 Regular Arming Switches to Force Arming (Not to be used with UL Installations) Section [131]: Arming/Disarming Options Option [2] OFF = Regular Arming Switches to Force Arming Disabled (default) Option [2] ON = Regular Arming Switches to Force Arming Enabled With this feature enabled, the control panel will always Force arm instead of Regular arm when a valid user access code with the Force Arming Option is entered. In installations where the user must always Force arm when leaving the protected area, this feature allows users to Force arm without pressing the [FORCE] key before entering their user access code. Force arming cannot be done using a keyswitch. Force arming is not supported by keyswitches. Restrict Arming on Battery Fail Section [130]: Arming/Disarming Options Option [5] OFF = Permit arming on battery failure (default) Option [5] ON = Restrict arming on battery failure If this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery is disconnected, that its fuse is blown, or that the battery voltage drops to less than 10.5V. The control panel will not arm the system until all battery trouble conditions are rectified. Restrict Arming on Tamper Failure Section [130]: Arming/Disarming Options Option [6] OFF = Permit arming on tamper failure (default) Option [6] ON = Restrict arming on tamper failure If this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one or more zones. The control panel will not arm the system until all tamper trouble conditions are rectified. This feature will not function if the Tamper Recognition Options (see page 25) are disabled or whenever the tampered zone is bypassed and the Tamper Bypass Options (see page 26) have been enabled. Timed Auto-Arming Section [133] = Partition 1, [134] = Partition 2 Option [1] OFF = Timed Auto-Arming Disabled (default) Option [1] ON = Timed Auto-Arming Enabled Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer. The Auto-arming Options (see page 24) determine the partition's arming method. Any open zones detected when a partition is Auto-Armed will be bypassed regardless of their definition (except 24Hr zones). The control panel will enter a 60-second exit delay period before arming the system. At this point, Auto-arming can be cancelled by entering a valid access code. Once the partition has successfully armed, the control panel can transmit the Timed Auto-arming report code programmed in section [172]. Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-arming for partition 2 by turning on option [1]
in section [134]. Then key in 18:15 into section [112]. 7.6.1 Auto-Arm Timer Section [111] = Partition 1, [112] = Partition 2 Select the section corresponding to the desired partition and program the time (use the 24-hour clock i.e. 6:30PM =
18:30) that you wish the control panel to attempt to arm the selected partition and/or send the Late to Close report code. No Movement Auto-Arming Section [133] = Partition 1, [134] = Partition 2 Option [2] OFF = No Movement Auto-Arming Disabled (default) Option [2] ON = No Movement Auto-Arming Enabled If no movement occurs in a partition's protected area for the period specified by the No Movement Timer (see page 24), the control panel can automatically arm that partition. The Auto-arming Option described on page 24 of this manual determines the partition's arming method. Any open zones detected when a partition is Auto-armed will be bypassed regardless of their definition
(except 24Hr zones). Upon arming, the control panel will transmit the No Movement report code if programmed in section [172]. Regardless of whether the system was successfully armed or not, the control panel will always transmit the No Movement report code if programmed in section [172]. If No Movement Auto-arming is disabled, the control panel will still send the No Movement report code at the time specified by the No Movement Timer. Example: To arm partition 1 whenever there is no movement for a period of 4 hours, enable No Movement Auto-arming for partition 1 by turning on the [2] Option in section [133]. Then in section [075] enter 016 (16x15min = 240min = 4 hours). Spectra 1759MG 23 7.7.1 No Movement Timer Section [075] = Partition 1, [076] = Partition 2 001 to 255 x15min, Default = Disabled Select the section corresponding to the desired partition and program the interval of time without movement you wish the control panel to wait before arming and/or sending the No Movement report code. If No Movement Auto-arming is disabled, the control panel can still send the No Movement report code when no movement has been detected for the period specified by the No Movement Timer. Auto-Arming Options (Not to be used with UL installations) Section [133] = Partition 1, [134] = Partition 2 Option [3] OFF = Regular Arming (default) Option [3] ON = Stay Arming When using Timed Auto-arming or No Movement Auto-arming (see pages 23 and 23), the control panel can Regular or Stay arm
(see page 44) the selected partition. One-Touch Arming (Not to be used with UL installations) Section [130]: Options [1] to [4]
Option [1] ON = Press & hold the [ENTER] key for One-touch Regular Arming. Option [2] ON = Press & hold the [STAY] key for One-touch Stay Arming. Option [3] ON = Press & hold the [FORCE] key for One-touch Force Arming. Option [4] ON = Press & hold the [BYP] key for One-touch Bypass Programming. The One-touch arming features allow users to arm the system without having to enter any access codes. To arm the system, press and hold the appropriate key (see above) for approximately 2 seconds. If the system is partitioned (see page 36), you must also press the key corresponding to the partition you wish to arm. For more information on the different arming methods, please refer to page 44. Exit Delay Section [071] = Partition 1, [072] = Partition 2 001 to 255 seconds, Default = 30 seconds, Maximum 60 seconds for UL Listed systems After entering the required arming sequence (i.e. user access code, etc.), the exit delay parameter determines the amount of time a user has to leave the protected area before the control panel arms the partition. The exit delay applies to all zones in the selected partition. When enabled, the keypad will beep once every second during the exit delay and will beep rapidly during the final 10 seconds of the exit delay. 7.10.1 Beep On Exit Delay Section [130]: Arming/Disarming Options Option [8] OFF = Beep on Exit Delay Disabled Option [8] ON = Beep on Exit Delay Enabled (default) Bell Squawk On Arm/Disarm with Keypad Section [130]: Arming/Disarming Options Option [7] OFF = Bell Squawk on Arm/Disarm Disabled (default) Option [7] ON = Bell Squawk on Arm/Disarm Enabled When this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming. Bell Squawk On Arm/Disarm with Remote Control Section [131]: Arming/Disarming Options Option [3] OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default) Option [3] ON = Bell Squawk on Arm/Disarm with Remote Control Enabled When this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon disarming with a remote control. Must be enabled for UL installations. No Exit Delay When Arming with Remote Control Section [131]: Arming/Disarming Options Option [4] OFF = Provides Exit Delay When Arming with a Remote Control (default) Option [4] ON = No Exit Delay When Arming with a Remote Control When the option is enabled, the panel cancels the exit delay (arms instantly) when a partition is armed with a remote control. When disabled, the exit delay timer will start when a partition is armed with a remote control. 7.8 7.9 7.10 7.11 7.12 7.13 24 Reference & Installation Manual 7.14 No Exit Delay Beeps and No Bell Squawk When Stay Arming Section [131]: Arming/Disarming Options Option [5] OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default) Option [5] ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the exit delay, whenever a partition is Stay armed. Part 8: Alarm Options 8.1 8.2 8.3 Bell Cut-Off Timer Section [073] = Partition 1, [074] = Partition 2 000 = Disabled, 001 to 255 minutes, Default = 4 minutes, 5 minutes minimum for ULC installations After an audible alarm, the bell or siren will stop upon disarming of the partition or when the Bell Cut-Off Timer has elapsed, whichever comes first. Recycle Alarm After the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If there are any open zones, the control panel will generate another alarm. In one armed period, the control panel will repeat this sequence the number of times defined by the Recycle Counter. 8.2.1 8.2.2 Recycle Alarm Delay Section [090]
000 = disabled, 001 to 255 minutes, Default = Disabled The Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before re-verifying zone status. Recycle Counter Section [091]
000 = disabled, 001 to 255, Default = Disabled The Recycle Counter determines the number of times the control panel will re-verify the zone status after Bell Cut-Off in one armed period. Tamper Recognition Section [132]: Zone Options
[1] OFF / [2] OFF: Tamper Recognition Disabled (default) If the system is armed or disarmed, the control panel will display the zone as open in the keypad display, but will not generate an alarm. This option is not permitted on UL systems.
[1] OFF / [2] ON: Trouble Only If the system is armed and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting
(see page 16). If the system is disarmed and a tamper wiring failure occurs on a zone, a Tamper/Zone Wiring Failure will appear in the keypads trouble display (see page 42) and the control panel will transmit the appropriate Zone Tamper report code (see page 29).
[1] ON / [2] OFF: Silent Alarm If the system is armed and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting
(see page 16). In a disarmed system, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system will have to be disarmed.
[1] ON / [2] ON: Audible Alarm In an armed system and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see page 16). In a disarmed system, it functions the same as Trouble Only setting, except it will also generate an audible alarm. Spectra 1759MG 25 8.4 8.3.1 Tamper Bypass Options Section [132]: Zone Options Option [3] OFF = Will generate a tamper if detected on a bypassed zone (default) Option [3] ON = Tampers on bypassed zones will be ignored With option [3] on, the Tamper Recognition feature follows the zone bypass definition. This means the control panel will ignore any tampers detected on a bypassed zone. With option [3] off, Tamper Recognition ignores the bypass definition. This means the control panel will generate an incident as per Tamper Recognition settings if a tamper or wire fault occurs on a bypassed zone. Keypad Panic Options Section [128]: General Options Option [1] OFF = Emergency Panic Disabled (default) Option [1] ON = Emergency Panic Enabled Pressing the [1] and [3] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [4]. Option [2] OFF = Auxiliary Panic Disabled (default) Option [2] ON = Auxiliary Panic Enabled Pressing the [4] and [6] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [5]. Option [3] OFF = Fire Panic Disabled (default) Option [3] ON = Fire Panic Enabled Pressing the [7] and [9] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [6]. Option [4] OFF = Emergency Panic is Silent (default) Option [4] ON = Emergency Panic is Audible Option [5] OFF = Auxiliary Panic is Silent (default) Option [5] ON = Auxiliary Panic is Audible Option [6] OFF = Fire Panic is Silent (default) Option [6] ON = Fire Panic is Pulsed Silent alarm:
The control panel emits a confirmation beep and transmits the appropriate Panic report code if programmed in section [195]. The control panel will not enable the keypad buzzers or the control panels BELL output (no audible alarm). Audible alarm:
Same as silent alarm, except the keypad buzzers and the BELL output will activate until a user cancels the alarm (disarms) with a valid user access code or when the Bell Cut-Off Timer elapses (see page 25). Fire (pulsed) alarm:
Same as audible operation, except that the BELL output will be pulsed as shown in Figure 11 on page 15. Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1. 8.5 Panic Lockout Timer Section [094]
When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control for a specified period. This prevents an aggressor from disarming the system by remote control during a panic situation. In section [094] enter a 3-digit value
(000 to 255, 000 = disabled) representing the number of seconds that the remote controls will be locked out of the system. 26 Reference & Installation Manual Part 9: Reporting and Dialer settings The following section explains all the features and options that must be programmed in order for your security system to properly report system events to a monitoring station. When an event (e.g. zone in alarm) occurs in the system, the control panel verifies if a report code was programmed in the section corresponding to the event (except Ademco Contact ID All Codes). If a report code was programmed, the control panel will dial the monitoring station telephone number defined by the Event Call Direction feature. When the monitoring station answers, the control panel will transmit the System Account Code, followed by the programmed report code. Figure 14: Event Reporting Reporting/Dialer Option [3] - Section [135]
Partition Account Numbers Partition 1 Partition 2 Partition Account Number 1 3 or 4 digits (0-F) in section [143]
Partition Account Number 2 3 or 4 digits (0-F) in section [144]
Monitoring Station Telephone Numbers 1 & 2 Sections [151] & [152]
Back-up Number Section [153]
Monitoring Station Telephone Numbers 1 & 2 Defines which monitoring station telephone numbers each group of events will report to. Section [137]
Option [1] ON = Call Telephone #1 for Arm/Disarm Report Codes Option [2] ON = Call Telephone #2 for Arm/Disarm Report Codes Option [3] ON = Call Telephone #1 for Alarm/Restore Report Codes Option [4] ON = Call Telephone #2 for Alarm/Restore Report Codes Option [5] ON = Call Telephone #1 for Tamper/Restore Report Codes Option [6] ON = Call Telephone #2 for Tamper/Restore Report Codes Section [138]
Option [1] ON = Call Telephone #1 for Trouble/Restore Report Codes Option [2] ON = Call Telephone #2 for Trouble/Restore Report Codes Option [3] ON = Call Telephone #1 for Special System Report Codes Option [4] ON = Call Telephone #2 for Special System Report Codes Related Features Delay Before Alarm Transmission Section [080]
Pager Format Delay Transmission Section [083]
Recent Closing Delay Section [085]
Power Failure Report Delay Section [086]
Auto Test Report Sections [087] & [110]
Report Disarm Options Option [1] - Section [131]
Report Zone Restore Options Option [6] - Section [132]
Alternate Dial Option [4] - Section [136]
Maximum Dialing Attempts Section [081]
Delay between Dialing Attempts Section [136]
Reporting Formats Section [140]
1st digit = CSTN#1 2nd digit = CSTN#2
[1] = Ademco Slow Pulse
[2] = Silent Knight Fast
[3] = Sescoa
[4] = Ademco Express
[6] = Pager
[5] = Ademco Contact ID DTMF
(Tone) Program 1 or 2-digit
(1 - FF) report codes into sections [160]
to [213] where each section represents up to four events in the system. Program the 2-digit report codes corresponding to the Contact I.D. Table into sections [160] to
[213] where each section represents up to four events in the system. Program FF to use the default Contact ID report code. Programmable Option [3] OFF - Section [136]
Programmable Option [3] ON - Section [136]
The control panel automatically generates all report codes. You do not have to program any report codes. Spectra 1759MG 27 9.1 9.2 Reporting/Dialer (Enable/Disable) Section [135]: Dialer Options Option [3] OFF = Reporting/Dialer Disabled (default) Option [3] ON = Reporting/Dialer Enabled Report Codes A report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 to F. Each section from [160] to [213] represents a set of up to four specific events and each of these events can be programmed with a separate 1- or 2-digit report code. Only the Ademco Slow, Silent Knight, Sescoa and Pager Formats support 1-digit report codes. To program a 1-
digit report code, press the [FORCE] key followed by the desired hexadecimal digit or vice versa. When a specific event occurs, the control panel will attempt to transmit the programmed report code to the monitoring station. The method of report code transmission is defined by the Reporting Formats (see page 30) and the Event Call Direction (see page 32). These two items define how and where the report codes are transmitted. If you are using the Ademco Contact ID All Codes format, sections [160] to [213] do not have to be programmed. For more information, refer to Reporting Formats on page 30. The following sub-sections provide a brief description of the events that the control panel can report. 9.2.1 9.2.2 9.2.3 9.2.4 Arming Report Codes Sections [160] to [171]
A report code can be programmed for each of the 48 user access codes. When using an access code to arm a partition, the control panel can send the appropriate report code to the monitoring station, identifying which access code was used to arm the partition. Special Arming Report Codes Sections [172] and [173]
Whenever the system is armed using one of the special arming features listed below, the control panel can send the appropriate report code to the monitoring station identifying how the system was armed. Section [172]
Timed Auto-Arming: A partition has armed itself at the programmed time (see page 23). Late to Close: Reports every day at the time specified by the Auto-arm Timer (see page 23). No Movement: A partition has armed itself after the programmed period without movement (see No Movement Auto-Arming on page 23). Partial Arming: A partition was Stay, Instant or Force armed or armed with Bypassed zones. Section [173]
One-Touch Arming: A partition was armed using a One-touch arming feature (see page 24). Remote Arming: A partition was armed using the Winload software. Keyswitch Arming: A partition was armed using a keyswitch (see page 14). Closing Delinquency: Partition 1 was not armed within a set period of time (see page 33). Disarming Report Codes Sections [174] to [185]
A report code can be programmed for each of the 48 user access codes. Whenever an access code is used to disarm an armed partition or a partition in alarm, the control panel can send the appropriate report code to the monitoring station, identifying which access code was used to disarm the partition. The Disarming and the Special Disarming report codes can be transmitted every time a partition is disarmed or only when a partition is disarmed after an alarm (see Disarm Reporting Options on page 33). Special Disarming Report Codes Section [186]
Whenever using one of the special disarming features, the control panel can send the report code to the monitoring station, identifying how the system was disarmed. Cancel Auto-Arm: A partition is disarmed during the Timed Auto-arm's 60-second exit delay (see Timed Auto-
Arming on page 23). Only reports if Disarming Reporting Options (see page 33) are set to always report disarming. Remote Disarm: System is disarmed using the Winload software. Keyswitch Disarming: System disarmed using a keyswitch (see page 14). Future use 9.2.5 Zone Alarm Report Codes Sections [187] to [190]
A report code can be programmed for each of the 15 available zones. Whenever a zone generates an alarm, the control panel can send the appropriate report code to the monitoring station, identifying which zone generated an alarm. 28 Reference & Installation Manual 9.2.6 9.2.7 9.2.8 9.2.9 9.2.10 Zone Alarm Restore Report Codes Sections [191] to [194]
A report code can be programmed for each of the 15 available zones. The control panel can transmit these report codes to the monitoring station identifying which zone was restored. A zone is restored when it closes after generating an alarm or once the bell has cut-off after alarm generation. Please refer to Zone Restore Report Options on page 34. Special Alarm Report Codes Sections [195] and [196]
Whenever the system generates an alarm due to one of the conditions listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of alarm. Section [195]
Emergency Panic: Panic keys [1] and [3] have been pressed (see page 26). Auxiliary Panic: Panic keys [4] and [6] have been pressed (see page 26). Fire Panic: Panic keys [7] and [9] have been pressed (see page 26). Recent Closing: Reports when an alarm is generated after arming the system within period defined by the Recent Close Delay (see page 33). Section [196]
Auto Zone Shutdown: A zone communicates more than the programmed number of transmissions in a single armed period (see page 16). Duress: A Duress access code is keyed in (see page 11). Keypad Lockout: If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads for a specified period. Future use Zone Tamper Report Codes Section [197] to [200]
A report code can be programmed for each of the 15 available zones. Whenever a tamper or wire fault occurs on a zone, the control panel can send the appropriate report code to the monitoring station identifying which zone was tampered. Zone Tamper Restore Report Codes Sections [201] to [204]
A report code can be programmed for each of the 15 available zones. Whenever a tampered zone is restored, the control panel can send the appropriate report code to the monitoring station identifying which zone has been restored. If Tamper Recognition (see page 25) is disabled, the control panel will not report the occurrence of any tampers, wire faults or tamper restores. System Trouble Report Codes Section [205] to [207]
Whenever the system generates one of the instances listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of system trouble. Section [205]
Future use AC Failure: The control panel has detected a loss of AC power. Transmission of this report code can be delayed
(see Power Failure Report Delay on page 33). Battery Failure: Backup battery is disconnected or battery voltage is 10.5V. Auxiliary Supply: Auxiliary power supply has overloaded (current consumption is >1.1A). Section [206]
Bell Output Overload: Bell/siren output has overloaded (see page 4). Bell Output Disconnected: Devices connected to the Bell Output have been disconnected. Timer Loss: The control panel has detected a loss in time or clock failure (see page 36). Fire Loop Trouble: The control panel has detected a tamper trouble on a fire zone. Section [207]
Wireless Low Battery: The battery voltage of an Magellan wireless transmitter (motion detector or contact switch) has dropped below recommended limits. Module Fault: Will report if all keypads connected to the control panel have been disconnected or if a module with its corresponding supervision option enabled in the control panel (see pages 38 and 39) is disconnected. Printer Fault: An error has occurred on the Printer Module. Fail To Communicate: The control panel has failed all attempts to communicate with the monitoring station. The report code will be transmitted upon the next successful attempt. Spectra 1759MG 29 9.2.11 9.2.12 System Trouble Restore Codes Sections [208] to [210]
Whenever the system restores one of the troubles listed in System Trouble Report Codes on page 29, the control panel can send the appropriate report code to the monitoring station identifying the type of system trouble restore. If Telephone Line Monitoring is enabled (see page 34), the control panel can also transmit a TLM Restore report code. Special Reporting Codes Sections [211] to [213]
Whenever the system generates one of the instances listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of system occurrence. Section [211]
Cold Start: The control panel was completely shutdown (no battery, no AC) and then was re-started. Test Report: A test report has been generated automatically (see Auto Test Report on page 33). Not available PC Exit: The control panel has ended communication with WinLoad. Section [212]
Future use Future use Section [213]
Tx Supervision Loss: Wireless Transmitter Supervision (see SPC-319 Instruction Sheet) has been enabled and a Installer In: Installer has entered the programming mode. Installer Out: Installer has exited the programming mode. transmitter is no longer communicating with the system. Tx Supervision Restore: Reports when the above trouble has been restored Future use Future use 9.3 9.4 9.5 Monitoring Station Telephone Numbers Section [151] = Phone#1, [152] = Phone#2, [153] = Backup Phone#: Up to 32 digits The 1759MG control panel can dial up to 2 different monitoring station telephone numbers. You can enter any digit from 0 to 9 and any special keys or functions (see Table 8) up to a maximum of 32 digits. For more information on how these telephone numbers are used, please refer to Event Call Direction on page 32 and Reporting Formats on page 30. After the Maximum Dialing Attempts (see page 33) to one monitoring station telephone number have failed, the control panel will then dial the backup telephone number. If the Alternate Dial Option (see page 33) is enabled, the control panel will dial the programmed backup telephone number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to the backup telephone number. Also refer to Delay Between Dialing Attempts on page 33. Table 8: Special Keys for Telephone Numbers Press
[STAY]
[BYP]
[MEM]
[TBL] or [TRBL]
[FORCE]
[PG] or [FNC1]
Action or Value
switch from pulse to tone dialing or vice versa 4-second pause deletes current digit inserts blank space Partition Account Numbers Section [143] = Partition 1, [144] = Partition 2 All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a partitioned system. Partition account numbers can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the [FORCE] key followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report codes. Reporting Formats Section [140]: 1st digit = Format for Phone #1, 2nd digit = Format for Phone #2 The Spectra 1759MG can use a number of different reporting formats and each monitoring station telephone number can be programmed with a different reporting format. The first digit entered into section [140] represents the reporting format used to communicate with Monitoring Station Telephone Number 1, the second digit represents the reporting format used to communicate with Monitoring Station Telephone Number 2. The Backup Telephone Number uses the same reporting format as the last monitoring station telephone number that was dialed. 30 Reference & Installation Manual Table 9: Reporting Formats Value Entered 1 2 3 4 5 (Default) 6 Reporting Format Ademco Slow (1400Hz, 1900Hz, 10BPS) Silent Knight Fast (1400Hz, 1900Hz, 10BPS) SESCOA (2300Hz, 1800Hz, 20BPS) Ademco Express (DTMF 4+2) Ademco Contact ID Pager Format 9.5.1 9.5.2 9.5.3 9.5.4 9.5.5 9.5.6 If Hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports Hexadecimals. If the pager does not support Hexadecimals, use only the digits 0 to 9. UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least once per year. Standard Pulse Formats The Spectra 1759MG can use the Ademco slow, Silent Knight and Sescoa standard pulse reporting formats (see Table 9 above). Ademco Express The Ademco Express is a high-speed reporting format, which will transmit the 2-digit (11 to FF) report codes programmed into sections [160] to [213]. Unlike other Ademco formats, the Ademco Express does not use the Contact ID report codes. Ademco Contact ID Ademco Contact ID is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator format also uses a pre-defined list of industry standard messages and report codes that will suit most of your basic installation needs. Please refer to the Contact ID Report Codes List in the Programming Guide for a complete list of these report codes and messages. Contact ID Options Section [136]: Dialer Options Option [3] OFF = Programmable Codes Option [3] ON = All Codes (default) When using the Programmable Codes format, use the Ademco Contact ID Report Codes List in the Spectra System Programming Guide (version 2.0 or higher) to program the desired report codes into sections [160] to [213]. Enter FF to use the default Contact ID report codes. Press the [FORCE] key to enter a 0 value. When using the All Codes format, the control panel will automatically generate Contact ID report codes for every event in sections [160] to [213]. Refer to the All Codes Ademco Contact ID Report Code List in the Spectra System Programming Guide. When using the Ademco Contact ID Programmable format, both telephone numbers must use this reporting format. Pager Reporting Format Section [136]: Dialer Options
[6] OFF / [7] OFF: 1 call to the pager/cellular telephone
[6] OFF / [7] ON: 2 calls to the pager/cellular telephone
[6] ON / [7] OFF: 3 calls to the pager/cellular telephone
[6] ON / [7] ON: 4 calls to the pager/cellular telephone Using this format allows the control panel to transmit report codes to a pager or a cellular telephone. Since the control panel cannot confirm whether the transmission was successful or not, it can be programmed to call the pager or cellular telephone up to four times and transmit the report codes each time. To ensure that the report is received, the control panel transmits the account number, the report code and the # sign four times during each call. Also, refer to Pager Delay on page 32. Pager Format Transmission Options Section [136]: Dialer Options Option [8] OFF = Transmit Report Code(s) after Pager Delay (default) Option [8] ON = Transmit Report Code(s) immediately The Pager Reporting Format can be configured to transmit immediately or to transmit after a pager delay has elapsed. With option [8] ON, the control panel will immediately transmit (personal dialing) the report code(s) to a pager or a cellular phone. The Pager delay in section [083] will then become the length of time that the control panel will continue to transmit the report code(s). With option [8] OFF, the control panel will transmit the report code(s) to a pager or cellular phone only after the Pager delay has elapsed. Spectra 1759MG 31 9.6 9.7 9.8 9.9 9.10 9.11 Pager Delay Section [083]
001 to 255 seconds, default = 5 seconds When using the Pager Reporting Format (see page 31), the control panel will wait for the Pager Delay period before transmitting the report codes. This is to allow time for the pager system to provide a dial tone or to bypass the welcome message before sending data. Event Call Direction Section [137]
Option [1] ON = Call Telephone #1 for Option [2] ON = Call Telephone #2 for Option [3] ON = Call Telephone #1 for Option [4] ON = Call Telephone #2 for Option [5] ON = Call Telephone #1 for Option [6] ON = Call Telephone #2 for Section [138]
Option [1] ON = Call Telephone #1 for Option [2] ON = Call Telephone #2 for Option [3] ON = Call Telephone #1 for Option [4] ON = Call Telephone #2 for Arm/Disarm Report Codes in sections [160] to [186] (page 28) Alarm/Restore Report Codes in sections [187] to [196] (pages 28 to 29) Tamper/Restore Report Codes in sections [197] to [204] (page 29) Trouble/Restore Report Codes in sections [205] to [210] (pages 29 to 30) Special Report Codes in sections [211] to [213] (page 30) This feature determines where each group of events will be reported. The control panel events are divided into five groups (see above) where each event group can be programmed to dial one or both monitoring station telephone numbers (MSTNs). When a reportable event occurs in the system, the control panel will verify that one of the two telephone numbers has been enabled. The control panel will begin by dialing the selected telephone number(s). If both numbers were selected it will begin with MSTN1. After the Maximum Dialing Attempts (see page 33) to one MSTN have failed, the control panel will then dial the backup telephone number. If the Alternate Dial Option (see page 33) is enabled, the control panel will dial the programmed backup telephone number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to the backup telephone number. Also, refer to Delay Between Dialing Attempts on page 33. Example: The system is armed and zone 1 has been breached causing an alarm. If option [3] is off and option [4] is on in section
[137], the control panel will attempt to communicate with MSTN2 in order to transmit the Zone 1 Alarm report code programmed in section [187]. Dialing Method Section [135]: Dialer Options Option [4] OFF = Pulse Dialing. (Also, refer to Pulse Ratio, below) Option [4] ON = Tone/DTMF Dialing (default) Pulse Ratio Section [135]: Dialer Options Option [5] OFF = European Pulse Ratio of 1:2 Option [5] ON = U.S.A. Pulse Ratio of 1:1.5 (default) When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2 pulse ratio, the 1:1.5 ratio may provide better results in some cases. The same applies for North American countries. If the 1:1.5 pulse ratio is not providing the desired results, the 1:2 ratio may be used. Bell on Communication Failure Section [135]: Dialer Options Option [6] OFF = Bell On Communication Failure Disabled (default) Option [6] ON = Bell On Communication Failure Enabled If the control panel fails to communicate with the monitoring station when the system is armed, it will enable the BELL output, setting off any bells or sirens connected to the output. Dial Tone Delay Section [136]: Dialer Options Option [5] OFF = Dialer will continue to dial if no dial tone is present after 4 seconds (default). Option [5] ON = Dialer will hang-up if no dial tone is present after 16 seconds 32 Reference & Installation Manual 9.12 Maximum Dialing Attempts Section [081]
001 to 016 attempts, Default = 8 attempts The value programmed in section [081] determines how many times the control panel will re-dial the same monitoring station telephone number before proceeding to the next number. 9.13 9.14 9.15 9.16 9.17 9.18 9.19 Delay Between Dialing Attempts Section [082]
000 to 255 seconds, Default = 20 seconds This delay determines the amount of time the control panel will wait between each dialing attempt. Alternate Dial Option Section [136]: Dialer Options Option [4] OFF = Alternate Dial Disabled (default) Option [4] ON = Alternate Dial Enabled With option [4] OFF, the control panel will dial the backup telephone number programmed in section [153] after all attempts to one monitoring station telephone number have failed (see Maximum Dialing Attempts on page 33). With option [4] ON, the control panel will dial the backup telephone number after every failed attempt. Recent Close Delay Section [085]
000 to 255 seconds, Default = no delay If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will attempt to transmit the Recent Close report code programmed in section [195]. Auto Test Report Sections [087]
000 = Disabled, 001 to 255 days, Default = Disabled Section [110]: Time (HH:MM) The control panel will transmit the Test Report report code programmed into section [211] after the number of days programmed into section [087] has elapsed at the time programmed into section [110]. Use the 24-hour clock to program the time (i.e. 6:30PM
= 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [110]. Example: Section [087] = 005 and section [110] = 13:00. The first Test Report will be sent at 1 PM that day and then the report will be sent every 5 days at 1 PM. Closing Delinquency Timer Section [095]
000 = Disabled, 001 to 255 days, Default = Disabled At midnight every day, the control panel will verify when the partition was last disarmed. If the partition has not been armed within the time programmed in the Closing Delinquency Timer, the control panel will transmit a Closing Delinquency event to the monitoring station. Example: The Closing Delinquency Timer for partition 1 in section [095] is programmed for 005 days. Spectra verifies when partition 1 was last disarmed at midnight every day. If partition 1 was not armed within the last 5 days, Spectra will transmit a Closing Delinquency event to the monitoring station. The Closing Delinquency Event and timer apply only to partition 1. Power Failure Report Delay Section [086]
001 to 255 minutes, Default = 15 minutes The control panel will transmit the AC Failure report code programmed in section [205] after the Power Failure Report Delay period has elapsed. Disarm Reporting Options Section [131]: Arming /Disarming Options Option [1] OFF = Always Report Disarming Option [1] ON = Report Disarming Only After Alarm (default) Spectra 1759MG 33 9.20 9.21 With option [1] OFF, the control panel will send the Disarming report codes (see page 28) to the monitoring station every time the system is disarmed. With option [1] ON, the control panel will send the Disarming report codes to the monitoring station when the system is disarmed following an alarm. Zone Restore Report Options Section [132]: Zone Options Option [6] OFF = Report On Bell Cut-Off (default) Option [6] ON = Report On Zone Closure With option [6] OFF, the 1759MG will send the Zone Alarm Restore report codes (see page 29) to the monitoring station when the zone has returned to normal and the Bell Cut-Off Timer has elapsed (see page 25). With option [6] ON, the 1759MG will send the Zone Alarm Restore report codes to the monitoring station as soon as the zone returns to normal or when the system is disarmed. Telephone Line Monitoring (TLM) When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM detects less than 3 volts for the period defined by the TLM Fail Timer. If the line test fails, the control panels STATUS LED flashes and generates one or more conditions as defined by the TLM settings below. These will be restored when the control panel detects the telephone line again. Please note that when the dialer detects an incoming call, the TLM test will stop for 1 minute. Section [135]: Dialer Options
[1] OFF / [2] OFF: TLM Disabled
[1] OFF / [2] ON: Trouble Only Upon line test failure, a TLM Trouble will appear in the keypads Trouble Display (see page 42).
[1] ON / [2] OFF: Alarm If System Armed Upon line test failure, a TLM Trouble will appear in the keypads Trouble Display (see page 42) and if the system is armed, the control panel will generate an alarm.
[1] ON / [2] ON: Silent Alarm Becomes Audible Upon line test failure, a TLM Trouble will appear in the keypads Trouble Display (see page 42) and causes a silent zone or silent panic alarm to switch to audible. 9.21.1 TLM Fail Timer Section [079]
016 to 255 x 2 seconds, Default = 32 seconds If TLM does not detect the existence of a telephone line for the duration of this period, the control panel will generate the condition(s) defined by the TLM options (see above). Part 10: Programmable Outputs A PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. For example, a PGM can be used to reset smoke detectors, activate bells or strobe lights, open/close garage doors and much more. When a PGM closes, the control panel supplies a ground to the PGM activating any device or relay connected to it. When a PGM opens, the circuit opens from ground, therefore, cutting power to any devices connected to it. PGM1 A programmable output that provides up to 150mA. Refer to Alarm Relay and PGMs on page 4. PGM2 PGM2 is a programmable output that can provide up to 1A. PGM2 is designed to be used as a Strobe Output. For information refer to PGM Strobe Options on page 35. For connections, refer to Alarm Relay and PGMs on page 4. Global PGM The Global PGM allows you to use the control panels PGM Event List to activate PGMs located on a module or LCD keypad. For example, if you enable a modules Follows Global PGM option, the PGM on the module will activate whenever the event programmed in section [124]
occurs. Every PGM on every keypad and/or expansion bus module can be programmed to follow the event(s) defined by the Global PGM. 10.1 PGM Activation Event Sections [120], [122], and [124]
This feature allows you to program the control panel to activate a PGM when a specific event occurs in the system. The PGM will remain in its active state until the programmed PGM Deactivation Event occurs or when the PGM Delay period elapses (see page 35). For the Event List see the PGM Table in the Spectra 1759MG Programming Guide. To program a PGM Activation Event:
34 Reference & Installation Manual 10.2 10.3 10.4 10.5 1) Enter section that represents the desired PGM. PGM1 = [120], PGM2 = [122], Global PGM = [124]
2) Enter the Event Group #. 3) Enter the Sub-Group #. 4) Enter the Partition # (01 = Partition 1 02 = Partition 2 99 = Both Partitions) The AC Loss PGM Event will only occur after the Power Failure Report Delay elapses (see page 33). PGM Deactivation Event Sections [121], [123], [125]
After PGM activation, the PGM will return to its normal state (deactivate) when the programmed PGM Deactivation Event occurs. Instead of deactivating the PGM when a specific event occurs, the PGM can deactivate after a programmed period elapses (see PGM Delay below). For the Event List see the PGM Table in the Spectra 1759MG Programming Guide. If using the PGM Delay, these sections can be used as a second activation event. 1) Enter section that represents the desired PGM. PGM1 = [121], PGM2 = [123], Global PGM = [125]
2) Enter the Event Group #. 3) Enter the Sub-Group #. 4) Enter the Partition # (01 = Partition 1 02 = Partition 2 99 = Both Partitions) PGM Delay Section [066] = PGM1, [067] = PGM2, [068] = Global PGM 001 to 255 seconds, 000 = Follows Deactivation Event, Default = 5 seconds Instead of deactivating the PGM on the occurrence of a specific event, the PGM will deactivate after the period programmed here has elapsed. If a PGM Delay is programmed, the deactivation event can be used as a second activation event. PGM Normal State Section [126]: Options [4], [5] and [6]
A PGM switches to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. You can program each PGM output to be normally open (N.O.) or normally closed (N.C.) by enabling or disabling options [4], [5] and
[6] in section [126]. Option [4] OFF = PGM1 Normally Open (Default) Option [4] ON = PGM1 Normally Closed Option [5] OFF = PGM2 Normally Open (Default) Option [5] ON = PGM2 Normally Closed Option [6] OFF = Global PGM Normally Open (Default) Option [6] ON = Global PGM Normally Closed PGM2 Strobe Options Section [129]: General Options Option [1] OFF = PGM2 Output is Steady (Default) Option [1] ON = PGM2 Output is Pulsed (Strobe) With option [1] enabled, PGM2 will flash on and off whenever activated. Otherwise, it will provide a steady output. Option [2] OFF = Disable PGM2 Pulse When System is Armed (Default) Option [2] ON = Enable PGM2 Pulse When System is Armed Whenever the system is armed, PGM2 will flash once every 30 seconds until the system is disarmed. Option [3] OFF = Disable PGM2 Pulse on Arm/Disarm (Default) Option [3] ON = Enable PGM2 Pulse on Arm/Disarm Enabled With this option enabled, PGM2 will flash once to indicate the system has been armed and will flash twice to indicate that the system has been disarmed. 10.6 Alarm Relay Options Section [127]: General Options Option [7] OFF = Alarm Relay Follows Bell Output (Default) Option [7] ON = Alarm Relay Follows Global PGM With this option off, the optional Alarm Relay will activate or deactivate whenever the Bell Output activates or deactivates. With the option on, the Alarm Relay will activate or deactivate whenever Global PGM activates or deactivates. Spectra 1759MG 35 11.1 11.2 11.3 11.4 11.5 11.6 11.7 Part 11: System Settings Hardware Reset Performing a hardware reset will set all control panel settings to factory default except for the Panel ID and PC Password. Also, the event buffer will not be erased. To perform a power down reset:
1) Make sure the Installer Lock is disabled (see below) 2) Remove battery and AC power from the control panel. 3) Set the RESET jumper to on by placing a jumper on the RESET pins of the control panel. 4) Re-connect AC and battery power to the control panel. 5) Wait 10 seconds and remove the jumper. Installer Lock Section [282]
000 = Disabled, 147 = Lock Enabled, Default = Disabled Program 147 into section [282] to lock all programming. Performing a hardware reset will not affect the current panel settings. To remove the Installer Lock, enter 000. Please note that four seconds after resetting the control panel the STATUS LED on the control panel will flash fast for 5 seconds to indicate that the installer lock is enabled. Keypad Lockout Feature Sections [092] and [093]
If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads for a specified period and send the report code programmed in section [196]. Program the number of consecutive invalid codes from 001 to 255 (000 = disabled) into section [092]. Program the duration of the Keypad Lockout from 001 to 255 minutes into section [093]. If 000 is programmed in section [093], the keypads will not be locked-out, but the report code programmed in section [196] will be sent. Battery Charge Current Section [127]: General Options Option [5] OFF = Battery Charge Current: 350mA (default) Option [5] ON = Battery Charge Current: 700mA (40VA transformer required) Partitioning Section [127]: General Options Option [1] OFF = Partitioning Disabled (default) Option [1] ON = Partitioning Enabled The 1759MG is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an office/warehouse building. When partitioned, each zone, each user code (see User Code Options on page 10) and some of the system's features can be assigned to Partition 1, Partition 2 or both (see Zone Partition Assignment on page 15). If the system is not partitioned, all user codes and features will be recognized as belonging to Partition 1. Users can only arm partitions to which they have been assigned. Only zones assigned to Partition 1 will arm/disarm when Partition 1 is armed or disarmed. Only zones assigned to Partition 2 will arm/disarm when Partition 2 is armed or disarmed. Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms. The following features can be programmed separately for each partition: Entry/Exit Delay Timer, Auto-arming Options, Bell Cut-Off Timer, Switch to Stay arming, PGM Events and Account Numbers. If the system is not partitioned, all zones, user codes, and features will be recognized as belonging to partition 1. Zones that have been manually assigned to partition 2 will no longer function. System Real-Time Clock Section [280]
Program the current time into section [280] using the 24-hour clock (i.e. 8:30PM = 20:30). Clock Adjust Section [088]
000 = Disabled, 001 to 255, Default = Disabled 001 to 127 = + 1 to +127 seconds 128 to 255 = -1 to -127 seconds 36 Reference & Installation Manual If you notice a gain or loss in control panel time, calculate the average gain or loss per day and program the opposite amount in order to automatically correct the time setting every 24 hours. Example: If a control panel loses 4 minutes per month, this represents an average loss of 8 seconds per day. Therefore, programming 008 (plus 8 seconds) into section [088] would compensate for the 8-second loss. 11.8 Keypad Tamper Supervision Section [128]: General Options Option [7] OFF = Keypad 1 Tamper Supervision Disabled (default) Option [7] ON = Keypad 1 Tamper Supervision Enabled Option [8] OFF = Keypad 2 Tamper Supervision Disabled (default) Option [8] ON = Keypad 2 Tamper Supervision Enabled The control panel can be programmed to monitor the on-board tamper status of one or two keypads in the system. If Keypad 1 Tamper Supervision is enabled, the control panel will verify the tamper status of a keypad with its keypad zone set as Keypad Zone 1. If Keypad 2 Tamper Supervision is enabled, the control panel will verify the tamper status of the keypad with its keypad zone set as Keypad Zone 2. Ensure that the keypads on-board anti-tamper switch is enabled. For LED keypads, see Configuring The LED Keypad on page 8. For LCD keypads, see the appropriate Installation Guide. Regardless of whether the keypad zones are being used or not, if more than one keypad is set with the same keypad zone number, Keypad Tamper Supervision will be lost for that keypad zone. For example, if two keypads in your system have their keypad zones defined as Keypad Zone 1, the control panel will not recognize a Keypad 1 Tamper Supervision Failure. If a keypad tamper occurs, the control panel can transmit the appropriate Zone Tamper report code (see page 29) as originating from the zones specified by the Table 10. If the zone (as specified by Table 10) is enabled, the control panel will report the tamper as originating from the partition where the zone is assigned. If the zone is not enabled, the control panel will send the Zone Tamper report code as originating from partition 1. A Tamper/Zone Wiring Failure will also appear in the keypads trouble display
(see page 42). Table 10: Zone Tamper Report Code for Keypad Tamper Supervision Failure Keypad Tamper Keypad 1 Tamper Supervision =
Keypad 2 Tamper Supervision =
1759MG Zone 6 Zone 7 When Reassign Keypad Zone 2 is enabled (see page 12), the Keypad Tamper Supervision for Keypad Zone 2 is lost. Therefore, Keypad Tamper Supervision will ONLY function on Keypad Zone 1. 11.9 Keypad Audible Trouble Warning Section [127]: General Options Option [3] OFF = Keypad Beep on Trouble Disabled Option [3] ON = Keypad Beep on Trouble Enabled (default) When enabled, the keypads emit an intermittent beep tone whenever a trouble condition occurs in the system. The intermittent beep tone remains activated until the user enters the trouble display by pressing the [TBL] or [TRBL] key. The intermittent beeps will re-initialize whenever a new trouble occurs or the trouble restores and re-occurs. 11.10 Confidential Mode Section [126] Options [1], [2] and [3]
Option [1] OFF = Confidential Mode Disabled (default) Option [1] ON = Confidential Mode Enabled Option [2] OFF = Keypads activate when an access code is entered Option [2] ON = Keypads activate when a key is pressed (default) Option [3] OFF = Confidential Mode Timer is 2 minutes Option [3] ON = Confidential Mode Timer is 5 seconds (default) If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the Confidential Mode Timer, all the keypads LEDs will be off and LCD screens will show Paradox Family until either a key is pressed or an access code is entered. When the system exits Confidential Mode, the keypads will display the systems status. Confidential Mode is activated by enabling option [1]. Option [2] regulates whether the keypads will be activated at the touch of a key or only when an access code is entered. Option [3] determines the amount of time without action before the system enters Confidential Mode (5 seconds or 2 minutes). Spectra 1759MG 37 11.11 Installer Quick Functions Keys After entering the Installer Code, you can press a key to perform specific actions as described below. 11.11.1 Installer Test Mode
[ENTER] + [INSTALLER CODE] + [TBL] / [TRBL]
The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the keypad will emit a confirmation beep to indicate opened zones. To enter this mode, simply enter the Installer Code then press the [TBL] or
[TRBL] key. The keypad will emit a confirmation beep. To disable this mode, press the [TBL] key again. The keypad will emit a rejection beep. 11.11.2 Test Report
[ENTER] + [INSTALLER CODE] + [MEM]
Sends the Test Report report code programmed in section [211] to the monitoring station (see Reporting and Dialer settings on page 27). 11.11.3 Call WinLoad Software
[ENTER] + [INSTALLER CODE] + [BYP]
Refer to page 40. 11.11.4 Cancel Communication
[ENTER] + [INSTALLER CODE] + [STAY]
Cancels all communication until the next reportable event. 11.11.5 Answer WinLoad Software
[ENTER] + [INSTALLER CODE] + [FORCE]
Refer to page 41. 11.12 PGM Modules Supervision Section [129]: General Options Option [7] OFF = 4-PGM Output Module Supervision Disabled (default) Option [7] ON = 4-PGM Output Module Supervision Enabled By enabling this option, the control panel will supervise the 4-PGM Output Module (APR3-PGM4) connected to the Spectra bus. This means that whenever the module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypads trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. 11.13 Printer Module Supervision Section [129]: General Options Option [8] OFF = Printer Module Supervision Disabled (default) Option [8] ON = Printer Module Supervision Enabled By enabling this option, the control panel will supervise the Printer Module (APR3-PRT1) connected to the Spectra bus. This means that whenever the Printer Module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypads trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. 11.14 Zone Expansion Bus Module Supervision Section [129]: General Options Option [4] OFF = Zone Expansion Bus Module Supervision Disabled (default) Option [4] ON = Zone Expansion Bus Module Supervision Enabled By enabling this option, the control panel will supervise the 4- or 8-Zone Expansion Bus Module (SPC/APR3-ZX4 or SPC/APR3-
ZX8) connected to the Spectra bus. This means that whenever the Zone Expansion Bus Module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypads trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. 38 Reference & Installation Manual 11.15 Wireless Transmitter Low Battery Supervision
= Wireless Transmitter Low Battery Supervision Disabled (default)
= Wireless Transmitter Low Battery Supervision Enabled Section [129]: General Options Option [6] OFF Option [6] ON When option [6] in section [129] is enabled and the battery voltage of an Magellan wireless transmitter (motion detector or contact switch) has dropped below recommended limits, the control panel will attempt to transmit the Wireless Transmitter Low Battery report code programmed in section [210] and the Wireless Transmitter Low Battery Failure will appear in the keypads trouble display (see page 42). 11.16 Wireless Transmitter Supervision Options Section [132]: Zone Options
[7] OFF / [8] OFF: Supervision Failure Recognition Disabled (default) When a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, the control panel will display the zone as open in the keypad display, but will not generate an alarm. When it occurs on in an armed system, the control panel will follow the zone's Alarm Types setting (see page 16). This option is not permitted on UL systems.
[7] OFF / [8] ON: Trouble Only When a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, a Wireless Transmitter Supervision Loss will appear in the keypads trouble display (see page 42) and the control panel will attempt to transmit the TX Supervision Loss report code programmed in section [213]. When it occurs on in an armed system, the control panel will follow the zone's Alarm Types setting (see page 16).
[7] ON / [8] OFF: Silent Alarm When a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system will have to be disarmed. In an armed system, the control panel will follow the zone's Alarm Types setting (see page 16).
[7] ON / [8] ON: Audible Alarm When a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only setting, except it will also generate an audible alarm. In an armed system, the control panel will follow the zone's Alarm Types setting (see page 16). 11.16.1 Restrict Arming on Supervision Loss Section [131]: Arming/Disarming Options Option [6] OFF = Disabled (default) Option [6] ON = Restrict Arming on Wireless Transmitter Supervision Loss The control panel will not allow users to arm the system if it receives a Supervision Loss signal. Please note that the Wireless Transmitter Supervision Options (see page 39) must be enabled. The control panel will not arm any partition until all Supervision Loss trouble conditions are rectified. 11.16.2 Supervision Bypass Options Section [131]: Arming/Disarming Options Option [7] OFF = Generate Supervision Loss if detected on a Bypassed Wireless Transmitter Zone
(default) Option [7] ON = No Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone When this feature is enabled, the Wireless Transmitter Supervision Options will follow the zone's bypass definition. This means the control panel will not perform any action if a Supervision Loss occurs on a bypassed zone. When this feature is disabled, the Wireless Transmitter Supervision Options will ignore the bypass definition. This means the control panel will generate an incident as per Wireless Transmitter Supervision Options if a supervision loss occurs on a bypassed zone. 11.17 Reprogram All Expansion Modules Section [750]
After removing an expansion bus module from the communication bus, the control panel keeps the modules programmed sections in memory. Therefore, if you add or replace a module or when you have downloaded the contents of the Paradox Memory Key (refer to Programming Using A Paradox Memory Key* on page 9), you can reprogram the modules with the settings saved in the control panel. To do so, enter section [750] and press [ENTER]. The keypad will emit 2 beeps every second while downloading. Spectra 1759MG 39 Part 12: Settings for WinLoad Software WinLoad has not been verified by UL 12.1 Panel Answer Options The following two options define how the control panel answers an incoming call from a computer using the WinLoad Software for Windows. 12.1.1 Answering Machine Override Section [077]
000 = Disabled, 010 to 255 seconds, Default = Disabled When using the WinLoad software to communicate remotely with an installation site that uses an answering machine or service, the answering machine override must be programmed. Using the WinLoad software you will call the control panel, hang up, then call back. If the installation site is called back within the programmed delay period, the control panel will override the answering machine or service by picking-up the line after the first ring on the second call. You must wait at least 10 seconds before attempting the second call, otherwise, the control panel will think it is the same call. For details on how to use the WinLoad software, refer to the WinLoad Help Manual. Example: A security installation is using an answering machine set to answer after three rings. If section [077] has been programmed with 040 (40 seconds) and the second call is made within 40 seconds, the control panel will pick up the line on the first ring. If it takes more than 40 seconds, the control panel will not answer on the first ring and the answering machine will answer after three rings. 12.1.2 Number of Rings Section [078]
000 = disabled, 001 to 015 rings, Default = 8 rings This value represents the number of rings the control panel will wait before picking-up the line. If the line is not answered after the number of programmed rings, the control panel will answer the call. You must wait at least 10 seconds before attempting the second call or the control panel will think it is the same call. 12.2 12.3 12.4 12.5 Panel Identifier Section [141]
0000 to FFFF This 4-digit code identifies the control panel to the WinLoad software before initiating communication. The control panel will verify that the Panel Identifier in the WinLoad software is the same. If the codes do not match, the control panel will not establish communication. Therefore, be sure to program the same panel identifier into both the Spectra control panel and the WinLoad software. PC Password Section [142]
0000 to FFFF This 4-digit password identifies the PC to the panel before establishing communication. Program the same PC Password into both the Spectra control panel and the WinLoad software. If the passwords do not match, the WinLoad software will not establish communication. PC Telephone Number Section [150]
Up to 32 digits The control panel will dial this number when trying to initiate communication with a computer using the WinLoad software. You can enter any digit from 0 to 9 and any special keys or functions (see Table 8 on page 30) up to a maximum of 32 digits. Call WinLoad Software
[ENTER] + [INSTALLER CODE] + [BYP]
The control panel will dial the PC Telephone Number programmed in section [150] in order to communicate with the WinLoad software. The control panel and the WinLoad software will verify that the Panel Identifier and the PC Password match before establishing communication. 40 Reference & Installation Manual 12.6 12.7 12.8 Answer WinLoad Software
[ENTER] + [INSTALLER CODE] + [FORCE]
In order to perform on-site upload/download connect your computer directly to the control panel using an ADP-1 line adapter. In the WinLoad software set Dialing Method to Blind Dial. Program the panel telephone number in WinLoad software and follow the instructions on the ADP-1 adapter. When the computer has dialed, press [ENTER] followed by the Installer Code, then press the
[FORCE] key to manually answer the WinLoad software from the control panel. Auto Event Buffer Transmission Section [136]: Dialer Options Option [2] OFF = Auto Event Buffer Transmission Disabled (default) Option [2] ON = Auto Event Buffer Transmission Enabled When the event buffer reaches 50% capacity, the control panel will make two attempts to establish communication with a PC using the WinLoad software by calling the PC Telephone Number programmed in section [150]. The WinLoad software must be in Wait to Dial mode. When the system establishes communication, it will upload the contents of the event buffer to the WinLoad software. If communication is interrupted before completing transmission or if after two attempts communication is not established, the system will wait until the Event Buffer attains another 50% capacity before attempting to re-communicate with the monitoring station. When the Event Buffer is full, each subsequent new event will erase the oldest event in the buffer. Call Back WinLoad Section [136]: Dialer Options Option [1] OFF = Call Back WinLoad Disabled (default) Option [1] ON = Call Back WinLoad Enabled For additional security, when a PC using the WinLoad software attempts to communicate with the control panel, the control panel can hang up and call the PC back in order to re-verify identification codes and re-establish communication. When the control panel hangs up, the WinLoad software automatically goes into Wait for Call mode, ready to answer when the control panel calls back. Please note that the PC Telephone Number must be programmed in section [150] in order to use the Call Back feature. Spectra 1759MG 41 Part 13: User Operation 13.1 Trouble Display The Spectra system continuously monitors fourteen possible trouble conditions. When a trouble condition occurs, the [TBL] key or
[TRBL] indicator will illuminate on the LED keypads or Trouble will appear on the LCD keypads screen. Press the [TBL] or [TRBL]
key to switch to the trouble display. The [TBL] key or [TRBL] indicator will flash and lights corresponding to an existing trouble condition will illuminate on the LED keypads (see Table 11) or the appropriate trouble message will appear on the LCD keypad. Press the [CLEAR] key to exit the trouble display. Please note that the keypad can be programmed to emit a BEEP every 5 seconds whenever a new trouble condition has occurred. Pressing the [TBL] or [TRBL] key will stop the beeping. LED #
[1]
Description No/Low Battery Failure
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Wireless Transmitter Low Battery Power Failure Bell Disconnected Maximum Bell Current Maximum Auxiliary Current Communicator Report Fail Timer Loss Tamper/Zone Wiring Fail
[10]
Telephone Line Monitoring
[STAY] or
[11]
Fire Loop Trouble Table 11: Trouble List Details The control panel performs a dynamic battery test under load every 60 seconds. This trouble indicates that the back up battery is disconnected or that the battery should be replaced, as it will not provide adequate current in case of AC loss. This trouble will also appear when the control panel is running on battery power and the battery voltage has dropped to 10.5V or lower. This means the battery must be recharged or replaced. The battery voltage of an Magellan wireless transmitter has dropped below recommended limits. To determine the zones generating the trouble, examine the Low Battery LED indicators on all the transmitters. The batteries should be replaced. Upon power failure, the AC LED on all keypads will turn off. The control panel can transmit the report code programmed in section [205]. This report code can be delayed by programming a Power Failure Report Delay in section [086]. The AC LED turns back on as soon as power is restored. This trouble occurs when a bell or siren is not connected to the bell output terminals. If you are not using the BELL terminals, connect a 1K resistor across the bell output. The BELL output uses a fuseless circuit and will automatically shut down if the current exceeds 3A. After opening the short or reducing the load, the bell current is restored upon the following alarm generation. This trouble indicator will only appear when a condition has occurred that would activate the bell output
(e.g. during an alarm). The auxiliary output uses a fuseless circuit to protect the power supply against current overload and automatically shuts down if the current exceeds 1.1A. After opening the short or reducing the load, the panel will restore power to the auxiliary output. The control panel has failed all attempts to communicate with the central monitoring station. The control panels internal clock must be re-programmed. To re-program the timer press the [8] key followed by the current time using the 24-hour clock
(i.e. 8:30PM = 20:30). If the Tamper Recognition options are enabled (see page 25), this trouble indicates a wiring problem on one or more zones or that the cover has been removed on one or more wireless transmitters. To provide line short recognition the zone connections must have EOL resistors. If you press the [9] key, the keypad will display which zones are in trouble. Enter the Installer Code to clear Tamper troubles. If the Telephone Line Monitoring (TLM) feature is enabled (see section [135]), this trouble indicates that the control panel has not detected the presence of a telephone line for 30 seconds. Indicates a wiring problem on a fire zone. Press [STAY] to view the zones that are generating this trouble. 42 Reference & Installation Manual LED #
[FORCE]
or [16]
Description Keypad Fault
[BYP]
or [12]
[MEM]
or [13]
Module Loss Wireless Transmitter Supervision Loss Table 11: Trouble List Details If the keypad is no longer communicating with the control panel, the [TBL] or [TRBL]
will flash, the [FORCE] key will illuminate (the LCD keypad displays Keypad Fault) and the keypad will emit four consecutive beeps at 5-second intervals. Press any key on the keypad to terminate the beeping sequence. When communication has been restored, the system will revert to previous status. A bus module is no longer communicating with the control panel. The modules supervision option must be enabled in section [129]. One or more wireless transmitters are no longer communicating with the receiver. If you press the [MEM] key, the keypad will display which zones are in trouble. 13.2 Programming Access Codes Access codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your system as well as activate or deactivate PGMs. The Spectra security system supports the following:
System Master Code arms or disarm partitions using any arming method and can create, modify or delete any user access code. Only the System Master Code can modify or delete user access codes assigned to both partitions. Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete user access codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete user access codes that are assigned to the same partition. 45 User Access Codes (including 1 Duress code) How Do I Program Access Codes?
1) Press [ENTER]. 2) Key in the [SYSTEM MASTER CODE] or [MASTER CODE]. 3) Key in 3-digit [SECTION] (see Table below). 4) Key in new 4- or 6-digit [ACCESS CODE].
[ENTER] flashes. Return to step 3. How Do I Delete Access Codes?
1) Repeat steps 1 to 3 (see above). 2) Press the [FORCE] key once for each digit in the access code (4 or 6 times) until the keypad emits a confirmation beep. Section
[001]
[002]
[003]
[004] to [047]
[048]
User Codes User Code 001 = System Master Code User Code 002 = Master Code 1 User Code 003 = Master Code 2 User Code 004 to User Code 047 User Code 048 or Duress Code 13.3 Disarming & Deactivating an Alarm To disarm an already armed system or to deactivate an alarm, simply key in a valid access code. Program a designated entry/exit point, such as the front door or the garage door with an entry delay timer. When these entry/exit point are opened (breached), it will set off a timer. The system will not generate an alarm until this timer elapses, giving users enough time to enter the premises and disarm the system. Any user can disarm the system, except users have been assigned the Arm Only Option. How Do I Disarm the System or Deactivate an Alarm?
1) Key in your [ACCESS CODE]*. The arm or alarm indication will turn off and the keypad will emit a confirmation beep.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to Disarm or to Disarm both partitions, press the [1] key then after the confirmation beep press the [2] key. Spectra 1759MG 43 13.4 Regular Arming This method, commonly used for day-to-day arming, will arm all the zones in the selected partition. If you make a mistake, the keypad will emit a rejection beep. When you have correctly armed the system, the appropriate ARM indication will turn on and the exit delay will be initiated. Please note that Regular arming can also be activated through Auto-arming, Keyswitch arming or One-
touch arming. How Do I Regular Arm?
1) Green READY indicator must be illuminated. Unless the system is partitioned, in which case all zones in the desired partition must be closed. 2) Key in a valid [ACCESS CODE]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to arm. To arm both partitions, press the [1] key then after the confirmation beep press the [2] key. 13.5 Stay Arming This method allows users to remain in the protected area while partially arming the system. For example, when going to sleep at night, entry/exit points like doors and windows can be armed while other zones like motion detectors remain deactivated. Please note that fire zones cannot be bypassed. 13.6 13.7 How Do I Stay Arm?
1) All zones in the desired partition (except Stay Zones) must be closed. 2) Press the [STAY] key. 3) Key in a valid [ACCESS CODE]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to Stay arm. To Stay arm both partitions, press the [1] key then after the confirmation beep press the [2] key. If you make a mistake, the keypad will emit a rejection beep. When you have correctly Stay armed the system, the appropriate ARM or STAY indication appears and the exit delay is initiated. Stay arming can also be activated using Auto-arming, Keyswitch arming or One-touch arming. The user code must have the Stay Arming Option enabled. Instant Arming After Stay arming the system and during its exit delay, press and hold the [STAY] key for 3 seconds. You should hear a confirmation beep. This will switch all armed zones to Instant zones. If you have access to both partitions:
To Instant arm one partition, press [STAY] + [ACCESS CODE] + Select Partition + [CLEAR] + press & hold [STAY]
To Instant arm both partitions, press [STAY] + [ACCESS CODE] + [1] + [2] + press & hold [STAY]
Force Arming (Not to be used with UL Installations) Force arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed. Force arming is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the system, if the motion detector is set as a Force Zone, the control panel will ignore the zone and allow users to arm the system even if the zone is open. Any open Force Zones at the time of arming will be considered deactivated by the control panel. If during this period a deactivated zone is closed, the control panel will revert that zone to active status, hence, will generate an alarm if breached. How Do I Force Arm?
1) All zones in the desired partition (except Force Zones) must be closed. 2) Press the [FORCE] key. 3) Key in a valid [ACCESS CODE]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to Force arm. To arm both partitions, press the [1] key then after the confirmation beep press the [2] key. If you make a mistake, the keypad will emit a rejection beep. When correctly Force armed, the appropriate arm indication appears and the exit delay will initiate. Please note that Force arming can also be activated using One-Touch Force arming. Also, note that the user access code must have the Force Arming Option enabled. 13.8 Manual Bypass Programming Manual Bypass Programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the system is armed. The access code must have the Bypass Programming Option enabled. Please note that fire zones cannot be bypassed. Manual Bypass Programming can also be activated using One-Touch Bypass Programming. 44 Reference & Installation Manual How do I Program Bypass Entries?
1) Press the [BYP] key. 2) Key in a valid [ACCESS CODE]*. 3) Select one or more [ZONES] you wish to bypass. 4) Once you have entered the desired bypass entries, press the [ENTER] key to accept these entries.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the desired partition. 13.8.1 Bypass Recall Feature After disarming the system, the control panel will erase the bypass entries. By using the Bypass Recall Feature, you can reinstate the previous bypass entries saved in memory. This eliminates the need to manually program the bypass entries every time you arm the system. The access code must have the Bypass Programming Option enabled. How Do I Recall Bypass Entries?
1) Press the [BYP] key. 2) Key in your [ACCESS CODE]*. 3) Press the [BYP] key. Previously bypassed zones will illuminate. 4) Press the [ENTER] key.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the desired partition. One-Touch Arming One-touch arming allows users to arm the system without using an access code. Simply press and hold a key. One-touch arming can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the system when leaving the protected area, without giving them access to any other alarm system operations. One-Touch Regular Arming: Press and hold the [ENTER] key for 3 seconds* to arm all zones in the partition. One-Touch Force Arming: Press and hold the [FORCE] key for 3 seconds* to bypass any open Force Zones. One-Touch Bypass Programming: Press and hold the [BYP] key for 3 seconds* to access Bypass Programming Mode. One-Touch Stay Arming: Press and hold the [STAY] key for 3 seconds* to arm all zones not defined as Stay Zones. Fast Exit - When the system is already Stay armed:
To Exit and Stay Arm: Press and hold the [STAY] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the system will return to Stay arming. To Exit and Regular Arm: Press and hold the [ENTER] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the control panel will switch to Regular arming. To Exit and Force Arm: Press and hold the [FORCE] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the control panel will switch to Force arming.
* If you have access to both partitions after activating a one-touch feature, press the key corresponding to the desired partition. To select both partitions, press the [1] key then after the confirmation beep press the [2] key. 13.9 13.10 Keyswitch Arming A keyswitch can be used to arm and disarm the system. Assign the keyswitch to a specific partition and program the keyswitch to Stay or Regular arm the assigned partition. Also program the keyswitch to function as a Maintained or Momentary keyswitch. To arm the system using a Maintained Keyswitch, set the keyswitch to the ON position. To disarm the system set the keyswitch to the OFF position. To arm the system using a Momentary Keyswitch, set the keyswitch to the ON position then turn it back to the OFF position. Repeating this sequence will disarm the system. 13.11 Panic Alarms In case of emergency, the Spectra system provides up to three panic alarms. These panic alarms, if programmed, will immediately generate an alarm after pressing and holding two specific keys for two seconds, as described below. Press and hold keys [1] and [3] for a panic alarm. Press and hold keys [4] and [6] for a panic or medical alarm. Press and hold keys [7] and [9] for a panic or fire alarm. 13.12 Auto-Arming (Not to be used with UL installations) Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer or for the period specified by the No Movement Timer. The user can program the Auto-arm Timer by using the System Master Code, Master Code 1 or Master Spectra 1759MG 45 Code 2. Please note that the control panel will enter a 60-second exit delay period before arming the system. At this point, Auto-
arming can be cancelled by entering a valid access code. 13.13 Alarm Memory Display A record of all alarm situations that occur will be stored in memory. After disarming the system, pressing the [MEM] key will display which zones were in alarm during the alarm period. To exit the Alarm Memory Display, press the [CLEAR] key. The control panel will erase the contents of the alarm memory every time the system is armed. 13.14 Programming Chime Zones Users can program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent beep tone (BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be Chime Programmed separately. 10-ZONE LED KEYPAD:
Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and hold the [1] key to enable chiming on zone 1. If after pressing and holding a key, the keypad emits a confirmation beep, this means the chime feature has been enabled for that zone. If the keypad emits a rejection beep, this means the chime feature has been disabled for the corresponding zone. 16-ZONE LED KEYPAD:
Press and hold the [9] key. Enter the 2-digit (01 to 15) zone number(s). When the corresponding LED is on, the zone is chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [ENTER]. LCD KEYPAD:
Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s), or use the arrow keys to scroll through the zones. and when the appropriate zone is displayed, press the [FNC1] key. When the desired zones are chimed, press [ENTER]. 13.15 Keypad Muting (Not to be used with UL installations) Press and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is pressed or when the keypad emits a Rejection or confirmation beep. All other beep functions are disabled. 13.16 Keypad Backlight (1686H and 1686V only) The illumination level behind the keys can be modified to suit the users needs. There are four backlight levels. The [MEM] key is used to set the desired level. Each consecutive push of the [MEM] key will increase the backlight level until the maximum level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated. To change the backlight level:
How do I Modify The Backlight?
1) Press and hold the [MEM] key for 3 seconds. 2) The [MEM] key will illuminate. 3) Press the [MEM] key to set the desired backlight level. 4) Press [CLEAR] or [ENTER] to exit. 46 Reference & Installation Manual FCC Warnings IMPORTANT INFORMATION This equipment complies with Part 68 of the FCC rules subpart D and CS-
03. Inside the cover of this equipment is a label that contains, among other information, the FCC registration number of this equipment. NOTIFICATION TO TELEPHONE COMPANY Upon request, customer shall notify telephone company of particular line to which the connection will be made, and provide the FCC registration number and the ringer equivalence of the protective circuit. FCC REGISTRATION NUMBER:5A7CAN-22633 - AL - E RINGER EQUIVALENCE NUMBER:0.1B (U.S. & CANADA) USOC JACK:
RJ31X (USA), CA31A (CANADA) TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and telephone company provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal equipment. Standard jacks shall be so arranged that, if plug connected thereto is withdrawn, no interference to operation of equipment at customer's premises which remains connected to telephone network shall occur by reason of such withdrawal. INCIDENCE OF HARM Should terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where practicable, notify customer that temporary disconnection of service may be required; however, where prior notice is not practicable, the telephone company may temporarily discontinue service if action is deemed reasonable in circumstances. In case of temporary discontinuance, telephone company shall promptly notify customer and will be given opportunity to correct the situation. CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communication facilities, equipment operations or procedures, where such actions are reasonably required and proper in its business. Should any such changes render customer's terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice to effect the modifications to maintain uninterrupted service. GENERAL This equipment shall not be used on coin telephone lines. Connection to party line service is subject to state tariffs. RINGER EQUIVALENCE NUMBER (REN) The ren is useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, sum of the ren's of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices that you may connect to your line, you may want to contact your local telephone company. EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment, please contact facility indicated below for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from network until problem is corrected or until you are sure that the equipment is not malfunctioning. FCC PART 15, WARNINGS INFORMATION TO USER This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to equipment intermittently, the user is encouraged to try to correct the interference by one or more of the following measures: (1) re orient or relocate the receiving antenna; (2) increase the separation between the equipment and receiver; (3) connect the equipment to an outlet on a circuit other than the one to which the receiver is connected, or (4) consult the dealer or an experienced radio/tv technician for assistance. CAUTION:
The user is cautioned that any changes or modifications not expressly approved by Paradox Security Systems could void the users authority to operate/use the equipment. WARRANTY Paradox Security Systems Ltd. (Seller) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the products inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Sellers maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty.
*BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. ATTACHMENT LIMITATION NOTICE The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Spectra Series 47 CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electrical inspection authority, or electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all of the devices does not exceed 100. Industry Canada certification is only applicable to installation of devices which include transformers approved by the Canadian Standards Association (CSA). RESTRICTIONS CONCERNANT LE RACCORDEMENT DE MATRIEL L'tiquette d'Industrie Canada identifie le matriel homologu. Cette tiquette certifie que le matriel est conforme certaines normes de protection, d'exploitation et de scurit des rseaux de tlcommunications. Le Ministre garantir toutefois pas que le matriel fonctionnera la satisfaction de l'utilisateur. Avant d'installer ce matriel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de tlcommunication. De plus, le matriel doit tre install en suivant une mthode acceptable de raccordement. L'abonn ne doit pas oublier qu'il est possible que la conformit aux conditions nonces ci-dessus n'empchent pas la dgradation du service dans certaines situations. Les rparations de matriel homologu doivent tre effectues par un centre de service d'entretien canadien autoris dsign par le fournisseur. La compagnie de tlcommunications peut demander l'utilisateur de dbrancher un appareil la suite de rparations ou de modifications effectues par l'utilisateur ou cause d'un mauvais fonctionnement. configuring the system:
All components of the system should be UL listed for the intended application. If the system will be used for Fire detection, the installer should refer to NFPA Standards #72, Chapter 2. In addition, once installation is complete, the local fire authority must be notified of the installation. This equipment must be verified by a qualified technician once every three years. All keypads must use an anti-tamper switch. Maximum allowed entry delay is 45 seconds. Maximum allowed exit delay is 60 seconds. Minimum 4 minutes for bell cut-off time. The following features do not comply with UL requirements: Bypass Recall and Auto Trouble Shutdown. Do not connect the primary indicating device to a relay. The installer must use the bell output. To comply with UL985, the auxiliary power output should not exceed 200mA. Please refer to Table 2: Current Consumption Table on page 4. Do not connect the zone ground terminal with UL Listed products. The metallic enclosure must be grounded to the cold water pipe. All outputs are Class 2 or power-limited, except for the battery terminal.The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R, CL3P, or substitute cable permitted by the National Electrical Code, ANSI/NFPA 70. RECOMMENDED:
EOL resistor part #2011002000 For UL Installations: Basler Electric BE156240CAA007 16.5VAC min 40VA 12Vdc 4Ah rechargeable acid/lead or gel cell backup battery (YUASA model #NP7-12 recommended) for residential use. Use a 7Ah battery to comply with fire requirements. Wheelock 46T-12 siren WARNING: This equipment must be installed and maintained by qualified service personnel only. 2002-2004 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply. Spectra, WinLoad, InTouch and Digiplex are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise la terre de la source d'energie lectrique, des lignes tlphoniques et des canalisations d'eau mtalliques, s'il y en a, sont raccords ensemble. Cette prcaution est particulirement importante dans les rgions rurales. AVERTISSEMENT: L'utilisateur ne doit pas tenter de faire ces raccordements lui-mme; il doit avoir recours une service d'inspection des installations lectriques, ou un lectricien, selon le cas. L'indice de charge (IC) assign chaque dispositif indique, pour viter toute surcharge, le pourcentage de la charge totale qui peut tre raccorde un circuit tlphonique boucl utilis par ce dispositif. La terminaison du circuit boucl peut tre constitue de n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l'ensemble des dispositifs ne dpasse pas 100. La certification d'Industrie Canada s'applique seulement aux installations d'appareils utilisant un transformateur approuv par l'Association Canadienne de Normalisation (CSA). UL AND ULC WARNINGS UL AND C-UL INSTALLATION NOTES This equipment is UL listed in accordance with standard UL1023
(Household Burglar -- Alarm Systems Units), standard UL985 (Household Fire Warning Units) and standard UL1635 (Digital Alarm Communicator System Units). This equipment has the capability of being programmed with features not verified for use in UL installations. To stay within these standards, the installer should use the following guidelines when 48 Reference & Installation Manual INDEX Numerics 24Hr. Buzzer Zone ...........................................................14 24Hr. Delayed Fire Zone .................................................15 24Hr. Standard Fire Zone ................................................15 A AC Failure Report Code ..................................................29 AC Power ...........................................................................2 Access Codes ..................................................................10 Length ........................................................................10 Programming ...............................................................43 Account Numbers ............................................................30 Ademco Contact ID ..........................................................31 Ademco Contact ID Options ............................................31 Ademco Express ..............................................................31 Adjust Clock .....................................................................36 Alarm Memory Display .....................................................46 Alarm Options ..................................................................25 Alarm Relay .......................................................................4 Options .......................................................................35 Alarm Report Code Transmission, Delay ........................17 Alarm Types .....................................................................16 Alternate Dial Option ........................................................33 Answer Upload/Download Software ................................38 Answer WinLoad Software ..............................................41 Answering Machine Override ...........................................40 Arming and Disarming Options ........................................22 Arming Report Codes ......................................................28 Auto Event Buffer Transmission ......................................41 Auto Force Arming ...........................................................23 Auto Test Report ..............................................................33 Auto Zone Shutdown .......................................................16 Counter .......................................................................16 Report Code ................................................................29 Auto-Arming On No Movement .........................................................23 Options .......................................................................24 Timer ..........................................................................23 Timing .........................................................................23 Auxiliary Panic Report Code ............................................29 Auxiliary Power ..................................................................4 Auxiliary Supply Report Code ..........................................29 B Backlight, Keypad ............................................................46 Backup Battery ..................................................................2 Battery Charge Current ....................................................36 Battery Failure Report Code ............................................29 Battery, Backup .................................................................2 Beep On Exit Delay .........................................................24 Beep On Trouble .............................................................37 Bell Cut-Off Timer ............................................................25 Bell on Communication Failure ........................................32 Bell Output Connection ....................................................................4 Disconnected Report Code ...........................................29 Overload Report Code ..................................................29 Bell Squawk On Arm/Disarm With Keypad ................................................................24 With Remote Control ....................................................24 Burglary Zones, 24 Hr. ....................................................14 Buzzer Zone ....................................................................14 Bypass Options, Supervision ...........................................39 Bypass Programming ......................................................44 Bypass Recall Feature .....................................................45 Bypass Zones ..................................................................16 C Call Back Feature ............................................................41 Call Upload/Download Software ......................................38 Call WinLoad Software ....................................................40 Cancel Auto-Arm Report Code ........................................28 Cancel Communication ....................................................38 Charge Current ................................................................36 Check-in Supervision .......................................................19 Chime Zones ...................................................................46 Clock Adjust .....................................................................36 Closing Delinquency ........................................................33 Report Code ................................................................28 Cold Start Report Code ...................................................30 Configuring The LED Keypads ..........................................8 Connecting Bells or Sirens ...............................................................4 Fire Zones .....................................................................6 Keypad Zones ...............................................................5 Keypads ........................................................................5 Keyswitches ..................................................................6 PGMs ...........................................................................4 Single Zone Inputs .........................................................5 Telephone Lines ............................................................4 Contact ID Options ..........................................................31 Counter, Auto Zone Shutdown ........................................16 Current Consumption Table ...............................................4 D Data Display Mode ............................................................7 Delay Before Alarm Report Code Transmission ........................17 Between Dialing Attempts .............................................33 Dial Tone ....................................................................32 Pager Report ...............................................................32 Power Failure Report ....................................................33 Delayed Fire Zone ...........................................................15 Dial Tone Delay ...............................................................32 Dialer settings ..................................................................27 Dialing Attempts ...............................................................33 Dialing Method .................................................................32 Disarm Reporting Options ...............................................33 Disarming .........................................................................43 Duress Code ....................................................................11 Duress Report Code ........................................................29 Spectra Series 49 E Emergency Panic Report Code ....................................... 29 Entry Delay ...................................................................... 14 EOL Zones ...................................................................... 17 Event Buffer Transmission .............................................. 41 Event Call Direction ......................................................... 32 Exclusive Zone Definitions Delayed Fire Zone ....................................................... 15 Keyswitch Zone ........................................................... 14 Standard 24Hr. Fire Zone ............................................. 15 Exit Delay ........................................................................ 24 Expansion Input ............................................................... 12 F Fail to Communicate Report Code .................................. 29 Feature Select Programming Method ................................ 7 Features, Wireless ........................................................... 18 Fire Circuits ....................................................................... 6 Fire Loop Trouble Report Code ....................................... 29 Fire Panic Report Code ................................................... 29 Fire Zone Delayed ...................................................................... 15 Standard 24 Hr. ........................................................... 15 Wireless ...................................................................... 15 Follow Zones ................................................................... 14 Force Arming ................................................................... 44 Force Zones .................................................................... 17 G Global PGM ..................................................................... 34 Ground ............................................................................... 2 H Hardware Reset ............................................................... 36 I Input Speed ..................................................................... 17 Installation ......................................................................... 2 Installer Code .......................................................................... 10 Lock ........................................................................... 36 Quick Functions Keys ................................................... 38 Test Mode ................................................................... 38 Installer In Report Code ................................................... 30 Installer Out Report Code ................................................ 30 Instant Arming ................................................................. 44 Intellizone ........................................................................ 16 K Key. See Memory Card Keypad Audible Trouble Warning .............................................. 37 Backlight ..................................................................... 46 Installation ..................................................................... 5 Lockout Report Code .................................................... 29 Muting ........................................................................ 46 Panic Options .............................................................. 26 Tamper Supervision ..................................................... 37 50 Reference & Installation Manual Keyswitch Zone Connection ........................................................... 5 Arming ........................................................................ 45 Arming, Report Code .................................................... 28 Connections .................................................................. 6 Disarming Report Code ................................................ 28 Options ....................................................................... 17 Zone ........................................................................... 14 L Late to Close Report Code .............................................. 28 Length of Access Codes .................................................. 10 Location and Mounting ...................................................... 2 Lock Master Code ........................................................... 11 Lock-out ........................................................................... 36 M Manual Bypass Programming ......................................... 44 Maximum Dialing Attempts .............................................. 33 Memory Card ..................................................................... 9 Memory Display ............................................................... 46 Module Fault Report Code .............................................. 29 Mounting ............................................................................ 2 Multiple Feature Select Programming Method .................. 7 Muting .............................................................................. 46 N No Arming On Battery Fail ............................................................ 23 On Supervision Loss .................................................... 39 On Tamper Trouble ...................................................... 23 No Audible Feedback Upon Stay Arming ........................ 25 No Exit Delay When Arming with Remote Control .......... 24 No Movement Auto-Arming ............................................. 23 No Movement Report Code ............................................. 28 Number of Rings .............................................................. 40 O One-Touch Arming .................................................... 24, 45 Report Code ................................................................ 28 Options Alarm .......................................................................... 25 Arming and Disarming .................................................. 22 Auto-Arming ................................................................ 24 Keyswitch ................................................................... 17 User code ................................................................... 10 Zone ........................................................................... 16 Override Answering Machine .......................................... 40 P Pager Delay .......................................................................... 32 Format Transmission Options ........................................ 31 Reporting Format ......................................................... 31 Panel Answer Options ..................................................... 40 Panel Identifier ................................................................. 40 Panic Alarms ................................................................... 45 Panic Options .................................................................. 26 Partial Arming Report Code .............................................28 Partition Account Numbers ..............................................30 Partition Assignment, Zone ..............................................15 Partitioning .......................................................................36 PC Exit Report Code .......................................................30 PC Password ...................................................................40 PC Telephone Number ....................................................40 PGM (Control Panel) Activation Event ...........................................................34 Deactivation Event .......................................................35 PGM Delay ..................................................................35 Strobe Options .............................................................35 PGM Activation, User Code Option .................................11 Power .................................................................................2 Power Failure Report Delay .............................................33 Printer Fault Report Code ................................................29 Programmable Output Connections ..................................4 Programmable Outputs ....................................................34 Programming Access Codes ..............................................................43 Chime Zones ...............................................................46 Methods ........................................................................7 Using a Keypad .............................................................7 Wireless Features ........................................................18 Wireless Fire Zone .......................................................15 Pulse Ratio ......................................................................32 Q Quick Arming ...................................................................24 Quick Functions Keys (Installer) ......................................38 R Real-Time Clock ..............................................................36 Reassign Zones to Expansion Inputs ..............................13 Recall Bypass ..................................................................45 Recent Close Delay .........................................................33 Recent Closing Report Code ...........................................29 Recycle Alarm ..................................................................25 Regular Arming ................................................................44 Regular Arming Switches to Force Arming ......................23 Remote Arming Report Code ..........................................28 Remote Controls Assigning to 1759EX ....................................................20 Assigning to User Access Codes ...................................21 Deleting ......................................................................20 Programming ...............................................................20 Programming Remote Control Buttons ...........................21 Remote Disarm Report Code ..........................................28 Report Code, Special Cold Start ....................................................................30 Installer In ...................................................................30 Installer Out .................................................................30 PC Exit ........................................................................30 Test Report .................................................................30 Tx Supervision Loss .....................................................30 Tx Supervision Restore .................................................30 Report Code, Special Alarm Auto Zone Shutdown ....................................................29 Auxiliary Panic .............................................................29 Duress ........................................................................29 Emergency Panic .........................................................29 Fire Panic ....................................................................29 Keypad Lockout ...........................................................29 Recent Closing ............................................................29 Report Code, Special Arming Closing Delinquency .....................................................28 Keyswitch Arming .........................................................28 Late to Close ...............................................................28 No Movement ..............................................................28 One-Touch Arming .......................................................28 Partial Arming ..............................................................28 Remote Arming ............................................................28 Timed Auto-Arming ......................................................28 Report Code, Special Disarming Cancel Auto-Arm ..........................................................28 Keyswitch Disarming ....................................................28 Remote Disarm ............................................................28 Report Code, System Trouble AC Failure ...................................................................29 Auxiliary Supply ...........................................................29 Battery Failure .............................................................29 Bell Output Disconnected ..............................................29 Bell Output Overload ....................................................29 Fail to Communicate .....................................................29 Fire Loop Trouble .........................................................29 Module Fault ................................................................29 Printer Fault .................................................................29 Timer Loss ..................................................................29 Wireless Low Battery ....................................................29 Report Codes ...................................................................28 Reporting and Dialer settings ..........................................27 Reporting Formats ...........................................................30 Re-Program All Expansion Modules ................................39 Reset, Hardware ..............................................................36 Restrict Arming On Battery Fail .............................................................23 On Supervision Loss ....................................................39 On Tamper Trouble ......................................................23 Rings ................................................................................40 S Single Zone Inputs .............................................................5 Software, Upload/Download ..............................................7 Special Alarm Report Codes ...........................................29 Special Arming Report Codes .........................................28 Special Disarming Report Codes .....................................28 Special Reporting Codes .................................................30 Standard 24Hr. Fire Zone ................................................15 Stay Arming ........................................................................44 Delay ..........................................................................22 Zones .........................................................................16 Strobe Options .................................................................35 Supervision Bypass Options ............................................39 Supervision Options, Wireless Transmitter ......................39 Switch to Stay Arming ......................................................22 System Master Code ................................................................10 Real-Time Clock ..........................................................36 Settings .......................................................................36 Trouble Report Codes ..................................................29 Spectra Series 51 Entry Delay 2 ............................................................... 14 Follow Zones ............................................................... 14 Instant Zones .............................................................. 14 Zone Options Alarm Types ................................................................ 16 Auto Zone Shutdown .................................................... 16 Delay Before Alarm Report Code Transmission ............... 17 Force Zones ................................................................ 17 Intellizone ................................................................... 16 Keyswitch Options ....................................................... 17 Stay Zones .................................................................. 16 Zone Partition Assignment .............................................. 15 Zone Programming .......................................................... 12 Zone Restore Report Options .......................................... 34 Zone Shutdown, Auto ...................................................... 16 Zone Speed ..................................................................... 17 Zone Tamper Report Codes .............................................................. 29 Restore Report Codes .................................................. 29 Zones Options Bypass Zones .............................................................. 16 Trouble Restore Codes ................................................. 30 T Tamper Bypass Options .................................................. 26 Tamper Recognition ........................................................ 25 Telephone Line Connection ............................................... 4 Telephone Line Monitoring (TLM) ................................... 34 Telephone Number, PC ................................................... 40 Telephone Numbers ........................................................ 30 Test Report Automatic .................................................................... 33 Manual ....................................................................... 38 Report Code ................................................................ 30 Timed Auto-Arming .......................................................... 23 Report Code ................................................................ 28 Timer ............................................................................... 33 Timer Loss Report Code ................................................. 29 Transformer Requirements ................................................ 2 Transmission Options, Pager Format .............................. 31 Trouble Display ................................................................ 42 Tx Supervision Loss Report Code ........................................................ 30 Restore Report Code .................................................... 30 U Upload/Download Software ............................................... 7 User Code Options Arm Only ..................................................................... 11 Bypass Programming ................................................... 11 Force Arming ............................................................... 11 Partition 1 Assignment .................................................. 10 Partition 2 Assignment .................................................. 11 PGM Activation ............................................................ 11 Stay Arming ................................................................ 11 User Operation ................................................................ 42 W Winload Software .............................................................. 7 Wireless Features ............................................................ 18 Wireless Fire Zone Programming .................................... 15 Wireless Low Battery Report Code ................................. 29 Wireless Transmitters Assigning .................................................................... 18 Check-in Supervision .................................................... 19 Check-in Supervision Timer Settings .............................. 20 Deleting ...................................................................... 18 Low Battery Supervision ......................................... 20, 39 Programming ............................................................... 18 Serial Number Display .................................................. 19 Supervision Options ..................................................... 39 Viewing Signal Strength ................................................ 19 Z Zone Alarm Report Codes ............................................... 28 Zone Alarm Restore Report Codes ................................. 29 Zone Definitions 24Hr. Burglary Zones ................................................... 14 24Hr. Buzzer ............................................................... 14 Entry Delay 1 ............................................................... 14 52 Reference & Installation Manual Notes For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S. call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.ca. 780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7444 Fax: (450) 491-2313 www.paradox.ca PRINTED IN CANADA 09/2004 1759MG-EI05
1 | Programming guide | Users Manual | 862.00 KiB | August 04 2005 |
1759MG System Programming Guide Software Version 2.0 Default Installer Code 0000 / 000000 (see section [281] on page 18) Default System Master Code 1234 / 123456 (see section [301] on page 18) How Do I Enter Programming Mode?
1) Press [ENTER]. 2) Enter your [INSTALLER CODE]. 3) Enter 3-digit [SECTION] you wish to program. 4) Enter required [DATA]. Decimal and Hexadecimal Programming Table Value or Action Values 1 to 9 A (hex only) B (hex only) C (hex only) D (hex only) E (hex only) F (hex only) Exit Without Saving Erase Current Digit Save Data (hex only) What Do I Press?
[1] to [9]
[0]
[STAY]
[BYP]
[MEM]
[TBL] / [TRBL]
[PG] / [FNC1]
[CLEAR]
[FORCE]
[ENTER]
10-Zone LED
[1] to [9]
[0 (10)]
[STAY]
[BYP]
[MEM]
[TBL]
[PG]
What Do I See?
16-Zone LED
[1] to [9]
[10]
[11]
[12]
[13]
[14]
[15]
LCD
[1] to [9]
0 B C D E F
[ARM1] & [STAY1] flash
[ENTER] flashes Displays next digit or next section Advances to the next section SECTION [ ]
Trouble Display Press the [TBL] or [TRBL] key to view the Trouble Display. Please note that the keypad can be programmed to emit a BEEP every 5 seconds whenever a new trouble condition has occurred. Press the [TBL] or [TRBL] key to stop the beeping.
[1] - No Battery or Low Battery
[2] - Wireless Transmitter Low Battery
[3] - Power Failure
[4] - Bell Output Disconnected
[5] - Maximum Bell Current
[6] - Maximum Auxiliary Current
[7] - Communicator Report Failure
* Press the illuminated key ([9], [STAY] or [MEM]) to view which zones are causing the trouble. Enter the Installer Code to clear Tamper troubles.
** Press [8] to re-program the time.
[8] - Timer Loss**
[9] - Tamper or Zone Wiring Failure*
[10] - Telephone Line Monitoring Failure
[11]/[STAY] - Fire Loop Trouble*
[12]/[BYP] - Module Loss
[13]/[MEM] - Wireless Transmitter Supervision Loss*
[16]/[FORCE] and [TBL]/[TRBL] flashes - Keypad Fault Spectra 1759MG - 1 - Programming Guide Table of Contents Default Installer Code...................................................................................................................................................... 1 Default System Master Code .......................................................................................................................................... 1 How Do I Enter Programming Mode? ............................................................................................................................. 1 Decimal and Hexadecimal Programming Table.............................................................................................................. 1 Trouble Display ............................................................................................................................................................... 1 Data Display Mode (LED Keypads Only) ........................................................................................................................ 5 Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)............................................................................... 5 Zone Programming.......................................................................................................................................................... 6 System Timers ................................................................................................................................................................ 8 Programmable Outputs ................................................................................................................................................... 9 System Options............................................................................................................................................................. 12 Communication Settings ............................................................................................................................................... 15 Report Codes ................................................................................................................................................................ 16 System Settings ............................................................................................................................................................ 18 User Code Options........................................................................................................................................................ 18 Reprogram All Modules................................................................................................................................................. 19 Paradox Memory Key (PMC-3) ..................................................................................................................................... 19 4-PGM Output Modules V2.0 ............................................................................................................ 20 PGM Programming........................................................................................................................................................ 20 Printer Module V2.0........................................................................................................................... 21 PGM Programming........................................................................................................................................................ 22 Clock Programming....................................................................................................................................................... 22 Voice-assisted Arm/Disarm Bus Module V2.0 ................................................................................ 23 Wireless Features.............................................................................................................................. 24 Zone Assignment .......................................................................................................................................................... 24 Serial Number Display................................................................................................................................................... 24 Signal Strength Display................................................................................................................................................. 24 Remote Control User Assignment................................................................................................................................. 25 Button Options............................................................................................................................................................... 25 Remote Control Assignment ......................................................................................................................................... 26 Zone Expansion Bus Modules ......................................................................................................... 27 PGM Programming (SPC-ZX8 and APR3-ZX8 Only) ................................................................................................... 27 User Operation .................................................................................................................................. 28 Partitioning .................................................................................................................................................................... 28 Programming Access Codes......................................................................................................................................... 28 Programming Chime Zones .......................................................................................................................................... 29 Keypad Muting .............................................................................................................................................................. 29 Keypad Backlight (1686H and 1686V Only).................................................................................................................. 29 Quick Function Keys ..................................................................................................................................................... 29 Appendix A - Ademco CID Report Code List (Prog.) ..................................................................... 30 Appendix B - Ademco CID Report Code List (All Codes).............................................................. 31 Bus Module Connections ................................................................................................................. 32 Printer Module (APR3-PRT1)........................................................................................................................................ 32 4-PGM Output Module (APR3-PGM4) ......................................................................................................................... 33 4-zone expansion Bus Module (SPC-ZX4 and APR3-ZX4) ......................................................................................... 33 Spectra 1759MG - 3 - Programming Guide Voice-assisted Arm/Disarm Bus Module (APR3-ADM2)............................................................................................... 34 8-Zone Expansion Bus Modules (SPC-ZX8 and APR3-ZX8) ...................................................................................... 35 Hardware Connections..................................................................................................................... 36 Single Zone Inputs ........................................................................................................................................................ 36 Connecting Fire Circuits, Keyswitches and PGMs........................................................................................................ 36 Programming a Wireless Fire Zone .............................................................................................................................. 36 Alarm Relay and PGM Connections ............................................................................................................................. 37 Connecting More Than Two Keypads........................................................................................................................... 37 AC Power & Backup Battery Connections .................................................................................................................... 37 Spectra 1759MG PCB Layout....................................................................................................................................... 38 Spectra 1759MG - 4 - Programming Guide Data Display Mode (LED Keypads Only) View the sections programming one digit at a time. Does not function with sections using Feature Select Programming. To access the Data Display Mode, press the [ENTER] key after entering a section and before entering any data. The three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode. Each time the [ENTER] key is pressed, the keypad will display the next digit in the current section and will continue through all the following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature Select Method. Press the [CLEAR] key at any time to exit the Data Display Mode. Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher) The keypads zone number, EOL definition and anti-tamper switch are programmed through the keypads programming mode. To do so:
How Do I Configure The Keypad?
1) Press [ENTER]
2) Enter your [INSTALLER CODE] (default: 0000 / 000000) 3) Press the [PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds. 4) Press the desired key ([1] to [3]. See below) 5) Press [ENTER] to exit programming mode PLEASE NOTE: After two minutes, the keypad exits programming mode. Key [1] - Keypad Zone Selection Key [1] determines whether the keypads zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF (not illuminated), the keypads zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypads zone is Keypad Zone 2. Refer to the Zone Recognition Table on page 6 for more information. Key [1] OFF - Keypad Zone 1 (default) Key [1] ON - Keypad Zone 2 Key [2] - EOL Definition Key [2] determines the keypad zones EOL definition. When key [2] is OFF (not illuminated), EOL is disabled and the keypad zone uses the on-board EOL resistor. When key [2] is ON (illuminated), EOL is enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra 1759MG PCB Layout on page 38 for more details). Key [2] OFF - EOL disabled Key [2] ON - EOL enabled (default) Key [3] - On-Board Tamper Key [3] enables or disables the keypads on-board anti-tamper switch. When key [3] is OFF (not illuminated), the anti-tamper switch is disabled. When key [3] is ON (illuminated), the anti-tamper switch is enabled. Key [3] OFF - On-board anti-tamper switch disabled Key [3] ON - On-board anti-tamper switch enabled PLEASE NOTE: The keypad can be ordered with or without an anti-tamper switch. If the keypad has no anti-
tamper switch, key [3] will be OFF by default. If the keypad has an anti-tamper switch, key [3] will be ON by default. Spectra 1759MG - 5 - Programming Guide Zone Programming When programming zones, the zone assignments are dependent on where the detection devices are connected to in the system (see Zone Recognition Table). In installations that require using mostly the expansion inputs, refer to Reassign Keypad Zone 2 (see section [126] option [7] on page 12) and Reassign zones to expansion inputs (see section [126] option
[8] on page 12). Do not assign inputs from different modules to the same expansion input. Zone Recognition Table Option [7]: OFF Option [8]: OFF Option [7]: ON Option [8]: OFF Option [7]: OFF Option [8]: ON Option [7]: ON Option [8]: ON Control Panel Input 1 =
Input 2 =
Input 3 =
Input 4 =
Input 5 =
Keypad Zone 1 =
Zone 2 =
Expansion Input 1 =
Input 2 =
Input 3 =
Input 4 =
Input 5 =
Input 6 =
Input 7 =
Input 8 =
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 N/A Zone 7 Zone 8 Zone 9 Zone10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 1 Zone 2 N/A N/A N/A Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 1 Zone 2 N/A N/A N/A Zone 3 N/A Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Option [7]
Option [8]
= not displayed on 10-Zone LED Keypads
= Reassign Keypad Zone 2
= Reassign zones to expansion inputs Spectra 1759MG - 6 - Programming Guide How Do I Program the Zones?
1) Press the [ENTER] key 2) Enter the [INSTALLER CODE] (Default: 0000 / 000000) 3) Enter 3-digit [SECTION]
4) Enter one digit from the Zone Definition table (see page 7) 5) Enter one digit from the Partition Assignment table (see page 7) 6) Select one or more options from the Zone Options table (see page 7) 7) Press the [ENTER] key Partition Assignment Empty - Zone Disabled 1 - Partition 1 2 - Partition 2 3 - Both Partitions Zone Definition Empty - Zone Disabled 1 - Entry Delay 1 2 - Entry Delay 2 3 - Follow 4 - Instant 5 - 24Hr Burglary 6 - 24Hr Buzzer Additional definitions for on-board terminals:
7 - Keyswitch 8 - Fire 24Hr 9 - Delayed Fire 24Hr
[FORCE] key = empty First Digit Second Digit Section Description Zone Definition Partition Assignment
[001] = Zone 01:
[002] = Zone 02:
[003] = Zone 03:
[004] = Zone 04:
[005] = Zone 05:
[006] = Zone 06:
[007] = Zone 07:
[008] = Zone 08:
[009] = Zone 09:
[010] = Zone 10:
[011] = Zone 11:
[012] = Zone 12:
[013] = Zone 13:
[014] = Zone 14:
[015] = Zone 15:
Defaults =
Empty Partition 1 Zone Options 1 - Auto Zone Shutdown 2 - Bypass Enabled 3 - Stay Zone 4 - 5 - Zone Alarm Type off off Audible alarm (steady) off on Audible alarm (pulsed) on off Silent alarm on on Generates a report only 6 - Intellizone 7 - Delay alarm transmission 8 - Force Zone Keyswitch Options 1 - off = Maintained on = Momentary 2 - off = Regular Arm on = Stay Arm Zone Options 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 and 2 ON Only the control panels on-board inputs can be defined as a Fire, Delayed Fire or a Keyswitch zone. The on-board zones are zones 01 to 05. To program a wireless fire zone, refer to Programming a Wireless Fire Zone on page 36. Spectra 1759MG - 7 - Programming Guide System Timers Section #
Decimal Value (000 to 255) ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. ___/___/___ x 10 msec. Description ZONE SPEED (ZONE 1) ZONE SPEED (ZONE 2) ZONE SPEED (ZONE 3) ZONE SPEED (ZONE 4) ZONE SPEED (ZONE 5) ZONE SPEED (ZONE 6) ZONE SPEED (ZONE 7) ZONE SPEED (ZONE 8) ZONE SPEED (ZONE 9) ZONE SPEED (ZONE 10) ZONE SPEED (ZONE 11) ZONE SPEED (ZONE 12) ZONE SPEED (ZONE 13) ZONE SPEED (ZONE 14) ZONE SPEED (ZONE 15) FUTURE USE PGM1 TIMER PGM2 TIMER ENTRY DELAY 1 ENTRY DELAY 2 EXIT DELAY 1 EXIT DELAY 2 BELL CUT-OFF TIMER (PARTITION 1) BELL CUT-OFF TIMER (PARTITION 2) NO MOVEMENT TIMER (PARTITION 1) NO MOVEMENT TIMER (PARTITION 2) ANSWERING MACHINE OVERRIDE DELAY NUMBER OF RINGS TLM FAIL TIMER DELAY ALARM TRANSMISSION MAXIMUM DIALING ATTEMPTS DELAY BETWEEN ATTEMPTS PAGER DELAY INTELLIZONE DELAY RECENT CLOSING DELAY POWER FAILURE REPORT DELAY AUTO TEST REPORT CLOCK ADJUST ___/___/___ seconds (000 = follow Deactivation Event) ___/___/___ seconds (000 = follow Deactivation Event) ___/___/___ seconds (000 = follow Deactivation Event) GLOBAL PGM TIMER ___/___/___ seconds ___/___/___ seconds ___/___/___ seconds ___/___/___ seconds ___/___/___ minutes (000 = no bell on alarm) ___/___/___ minutes (000 = no bell on alarm) ___/___/___ x 15 minutes (000 = disabled) ___/___/___ x 15 minutes (000 = disabled) ___/___/___ seconds (minimum 10 sec.) ___/___/___ (000 = no answer, maximum = 15 rings) ___/___/___ x 2 sec. (minimum 32 sec.) ___/___/___ seconds ___/___/___ (000 = 16, maximum = 16) ___/___/___ seconds ___/___/___ seconds ___/___/___ seconds (minimum 10 sec.) ___/___/___ seconds ___/___/___ minutes ___/___/___ days (000 = disabled) ___/___/___ 000 to 127 = +1 to +127 seconds 128 to 255 = -1 to -127 seconds ___/___/___ (000 = disabled, maximum = 15) ___/___/___ minutes (000 = disabled) ___/___/___ (000 = disabled) ___/___/___ attempts before locking (000 = disabled) ___/___/___ minutes (000 = disabled) ___/___/___ seconds (000 = disabled) ___/___/___ days (000 = disabled) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) AUTO ZONE SHUTDOWN COUNTER 5 RECYCLE ALARM DELAY Disabled RECYCLE ALARM COUNTER Disabled KEYPAD LOCKOUT Disabled KEYPAD LOCKOUT DELAY Disabled PANIC LOCKOUT TIMER Disabled CLOSING DELINQUENCY TIMER (PARTITION 1) Disabled AUTO TEST REPORT (TIME OF DAY) Disabled AUTO-ARM TIME (PARTITION 1) Disabled AUTO-ARM TIME (PARTITION 2) Disabled Default 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 5 sec. 5 sec. 5 sec. 45 sec. 45 sec. 30 sec. 30 sec. 4 min. 4 min. Disabled Disabled Disabled 8 rings 32 sec. Disabled 8 attempts 20 sec. 5 sec. 48 sec. No delay 15 min. Disabled Disabled
[050]
[051]
[052]
[053]
[054]
[055]
[056]
[057]
[058]
[059]
[060]
[061]
[062]
[063]
[064]
[065]
[066]
[067]
[068]
[069]
[070]
[071]
[072]
[073]
[074]
[075]
[076]
[077]
[078]
[079]
[080]
[081]
[082]
[083]
[084]
[085]
[086]
[087]
[088]
[089]
[090]
[091]
[092]
[093]
[094]
[095]
[110]
[111]
[112]
Spectra 1759MG - 8 - Programming Guide Programmable Outputs Each PGM Deactivation event can be used as another start (activation) event if their respective PGM timer (see sections
[066] to [068]) is programmed with a value other than 000. Example: section [120] = 05 03 02: this means PGM1 will activate whenever partition 2 is Stay Armed. Section #
[120] PGM 1 PGM Activation Event
[121] PGM 1 PGM Deactivation Event
[122]
[123]
PGM 2 PGM Activation Event PGM 2 PGM Deactivation Event
[124] Global PGM Activation Event
[125] Global PGM Deactivation Event Used to activate PGMs on expansion modules & LCD keypads. Event Group # Sub-Group # Partition #
___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ 01 = Partition 1 02 = Partition 2 99 = Any Partition The Sub-Groups proceeded by
(Partition 1) cannot be assigned to activate Partition 2. Event Group #
Sub-Group #
00 = Zone OK 01 = Zone Open 02 = Partition Status 05 = Non-Reportable Events 06 = Arm/Disarm with Remote Control 07 = Button Pressed on Remote
(see button option B on page 25) 08 = Button Pressed on Remote
(see button option C on page 25) 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 00 = System not ready (Partition 1 only) 01 = System ready (Partition 1 only) 02 = Steady Alarm in Partition 03 = Pulsed Alarm in Partition 04 = Pulsed or Steady Alarm in Partition 05 = Alarm in Partition Restored 06 = Bell Squawk Activated (Partition 1 only) 07 = Bell Squawk Deactivated (Partition 1 only) 08 = Ground start (Partition 1 only) 09 = Disarm Partition 10 = Arm Partition 11 = Entry Delay (breach when system is armed) 99 = Any Sub-Group 00 = Telephone Line Trouble (Partition 1 only) 01 = [PG] or [FNC1] key was pressed (Partition 1 only). This option can also be used to reset smoke detectors. 02 = Instant Arming 03 = Stay Arming 04 = Force Arming 05 = Fast Exit (Force & Regular Only) 06 = PC Fail to Communicate (Partition 1 only) 07 = Midnight (Partition 1 only) 99 = Any Sub-Group (Partition 1 only, except 02 to 05) 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control Spectra 1759MG - 9 - Programming Guide Event Group #
09 = Button Pressed on Remote
(see button option D on page 25) 10 = Bypass Programming 11 = User Activated PGM 12 = Zone with Delay Transmission Option Enabled is Breached 13 = Arm with User Code 14 = Special Arm 15 = Disarm with User Code 16 = Disarm After Alarm w/ User Code 17 = Cancel Alarm with User Code 18 = Special Disarm 19 = Zone Bypassed on Arming 20 = Zone in Alarm 21 = Fire Alarm 22 = Zone Alarm Restore 23 = Fire Alarm Restore 24 = Special Alarm 25 = Auto Zone Shutdown 26 = Zone Tamper 27 = Zone Tamper Restore Sub-Group #
01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 (Partition 1 only) 99 = Any User Code 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 00 = Auto Arming (timed/no movement) 01 = Late to Close (Auto-Arming failed) 02 = No Movement Auto-Arming 03 = Partial Arming (Stay, Force, Instant, Bypass) 04 = One-Touch Arming 05 = Arm with WinLoad Software 07 = Closing Delinquency (Partition 1 only) 99 = Any Sub-Group 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 00 = Cancel Auto Arm (timed/no movement) 01 = Disarm with WinLoad Software 02 = Disarm after alarm with WinLoad Software 03 = Cancel Alarm with WinLoad Software 99 = Any Sub-Group 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 00 = Emergency Panic 01 = Auxiliary Panic 02 = Fire Panic 03 = Recent Closing 04 = Auto Zone Shutdown 05 = Duress Alarm 06 = Keypad Lockout 99 = Any Sub-Group 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone Spectra 1759MG - 10 - Programming Guide Event Group #
28 = System Trouble 29 = System Trouble Restore 30 = Special Reporting 31 = Wireless Transmitter Supervision Loss 32 = Wireless Transmitter Supervision Loss Restore 33 = Arming with a Keyswitch 34 = Disarming with a Keyswitch 35 = Disarm after Alarm with a Keyswitch 36 = Cancel Alarm with a Keyswitch 37 = Wireless Transmitter Low Battery 38 = Wireless Transmitter Low Battery Restore Sub-Group #
01 = AC Loss: only after Power Failure Delay has elapsed
(Partition 1 only) 02 = Battery Failure (Partition 1 only) 03 = Auxiliary current overload (Partition 1 only) 04 = Bell current overload (Partition 1 only) 05 = Bell disconnected (Partition 1 only) 06 = Timer Loss (Partition 1 only) 07 = Fire Loop Trouble (Partition 1 only) 08 = Future Use 09 = Module Fault (Partition 1 only) 10 = Printer Fault (Partition 1 only) 11 = Fail to Communicate (Partition 1 only) 99 = Any Sub-Group (Partition 1 only) 00 = TLM restore (Partition 1 only) 01 = AC Loss restore (Partition 1 only) 02 = Battery Failure restore (Partition 1 only) 03 = Auxiliary current overload restore (Partition 1 only) 04 = Bell current overload restore (Partition 1 only) 05 = Bell disconnected restore (Partition 1 only) 06 = Timer Programmed (Partition 1 only) 07 = Fire Loop Trouble restore (Partition 1 only) 08 = Future Use 09 = Module Fault restore (Partition 1 only) 10 = Printer Fault restore (Partition 1 only) 11 = Fail to Communicate restore (Partition 1 only) 99 = Any Trouble Restore (Partition 1 only) 00 = System Power Up (Partition 1 only) 01 = Test Report (Partition 1 only) 02 = WinLoad Software Access (Partition 1 only) 03 = WinLoad Software Access finished (Partition 1 only) 04 = Installer enters programming mode (Partition 1 only) 05 = Installer exits programming mode (Partition 1 only) 99 = Any Sub-Group (Partition 1 only) 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 01 to 05 = Zones 1 to 5 (on-board inputs) 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone 01 to 15 = Zones 1 to 15 99 = Any Zone Event Group #
Sub-Group #
Partition #
80 = PGM follows Clock (APR3-PGM4 only) HH = hour according to 24hr. clock MM = minutes according to 24hr. clock Spectra 1759MG - 11 - Programming Guide System Options Bold = Default Setting Section [126]: General Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Confidential Mode To exit Confidential Mode Confidential Mode timer PGM1 normal state PGM2 normal state Global PGM normal state Reassign Keypad Zone 2*
Reassign zones to expansion inputs*
OFF
Disabled
Enter Access Code
2 minutes
Normally Open (N.O.)
Normally Open (N.O.)
Normally Open (N.O.)
Disabled
Disabled ON
Enabled
Press a Key
5 seconds
Normally Closed (N.C.)
Normally Closed (N.C.)
Normally Closed (N.C.)
Enabled
Enabled
* Reassign Keypad Zone 2 and Reassign zones to expansion inputs change the zone numbering to increase the number of expansion inputs that can be displayed on 10-Zone LED Keypads. Refer to the Zone Recognition Table on page 6 and the Spectra 1759MG Reference & Installation Manual for details. Section [127]: General Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Partitioning Access code length Keypad audible trouble warning Lock System Master Code Battery charge current User Code 048 is a Duress Code Alarm relay follows Future use Section [128]: General Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Panic 1: keys [1] & [3]
Panic 2: keys [4] & [6]
Panic 3: keys [7] & [9]
Panic 1: silent or audible Panic 2: silent or audible Panic 3: silent or fire Keypad 1 tamper supervision Keypad 2 tamper supervision Section [129]: General Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
PGM2 output activation option PGM2 pulse once every 30 sec. if system armed PGM2 pulse on Arm, twice on Disarm ZX4 & ZX8 zone expansion module supervision Future use Wireless module low battery supervision 4-PGM Output Module supervision (APR3-PGM4) Printer Module supervision (APR3-PRT1) OFF
Disabled
6-digits
Disabled
Disabled
350mA
Disabled
Bell Output
N/A OFF
Disabled
Disabled
Disabled
Silent
Silent
Silent
Disabled
Disabled OFF
Steady
Disabled
Disabled
Disabled
N/A
Disabled
Disabled
Disabled Spectra 1759MG - 12 - Programming Guide ON
Enabled
4-digits
Enabled
Enabled
700mA
Enabled
Global PGM
N/A ON
Enabled
Enabled
Enabled
Audible
Audible
Fire
Enabled
Enabled ON
Pulse (flash)
Enabled
Enabled
Enabled
N/A
Enabled
Enabled
Enabled Bold = Default Setting Section [130]: Arming/Disarming Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
One-touch Regular Arming One-touch Stay Arming One-touch Force Arming One-touch bypass programming Restrict arming on battery failure Restrict arming on Tamper failure Bell Squawk on Arm/Disarm with keypad Beep on exit delay Section [131]: Arming/Disarming Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Report Disarming Regular Arming switches to Force Arming *
Bell Squawk on Arm/Disarm with remote control
(must be enabled for UL installations) No exit delay when Arming with a remote control No exit delay beeps and no Bell Squawk when Stay Arming Restrict arming on wireless transmitter supervision loss Generate supervision loss if detected on bypassed wireless zone Future Use OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled OFF
Always
Disabled
Disabled
Disabled
Disabled
Disabled
Yes
N/A ON
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled ON
Only after alarm
Enabled
Enabled
Enabled
Enabled
Enabled
No
N/A
* This option cannot be done using a keyswitch. Force arming is not supported by keyswitches. Section [132]: Zone Options Option
[1]&[2]
Tamper Recognition Options
[3]
[4]
[5]
[6]
[7]&[8]
[1]
OFF OFF ON ON
[2]
OFF Disabled (default) ON When disarmed: GENERATES TROUBLE ONLY When armed: Follows Zone Alarm Types OFF When disarmed: GENERATES SILENT ALARM When armed: Follows Zone Alarm Types ON When disarmed: GENERATES AUDIBLE ALARM When armed: Follows Zone Alarm Types Generate tamper if detected on bypassed zone EOL (end-of-line) resistors Future use Report zone restore Wireless Transmitter Supervision Options
[7]
OFF OFF ON ON
[8]
OFF Disabled (default) ON When disarmed: GENERATES TROUBLE ONLY When armed: Follows Zone Alarm Types OFF When disarmed: GENERATES SILENT ALARM When armed: Follows Zone Alarm Types ON When disarmed: GENERATES AUDIBLE ALARM When armed: Follows Zone Alarm Types OFF
see table
see table ON
see table
see table
Yes
No EOL
N/A
On Bell Cut-off
see table
see table
No
Use EOL Resistors
N/A
On Zone Closure
see table
see table Spectra 1759MG - 13 - Programming Guide Bold = Default Setting Section [133]: Partition 1 Options Option
[1]
[2]
[3]
[4]
[5]
Auto-arm on time Auto-arm on no movement Auto Arming = Regular or Stay Switch to Stay Arming if no entry delay is opened Stay Arming with Delay Partition 1 (Delay = [070])
[6] to [8] Future use Section [134]: Partition 2 Options Option
[1]
[2]
[3]
[4]
[5]
Auto-arm on time Auto-arm on no movement Auto Arming = Regular or Stay Switch to Stay Arming if no entry delay is opened Stay Arming with Delay Partition 2 (Delay = [070])
[6] to [8] Future use Section [135]: Dialer Options Option
[1] & [2]
Telephone Line Monitoring (TLM) Options
[2]
OFF TLM Disabled (default) ON OFF TLM generates an audible alarm if armed ON TLM generates a trouble if armed Silent alarms become audible
[1]
OFF OFF ON ON OFF
Disabled
Disabled
Regular Arming
Disabled
Disabled
N/A OFF
Disabled
Disabled
Regular Arming
Disabled
Disabled
N/A OFF
see table
see table ON
Enabled
Enabled
Stay Arming
Enabled
Enabled
N/A ON
Enabled
Enabled
Stay Arming
Enabled
Enabled
N/A ON
see table
see table
[3]
[4]
[5]
[6]
Reporting (Dialer) Dialing method Pulse ratio If armed, activate bell output on Com. Failure
[7] & [8] Future use
Disabled
Pulse Dialing
1:2
Disabled
N/A
Enabled
Tone (DTMF) Dialing
1:1.5
Enabled
N/A Section [136]: Dialer Options Option
[1]
[2]
[3]
[4]
[5]
Call back WinLoad Automatic event buffer transmission Contact I.D. report codes Alternate dial If no dial tone is present
[6] & [7]
Pager Reporting Format Dialer Options
[6]
OFF OFF ON ON
[7]
OFF ON OFF ON 1 call to pager or cellular telephone (default) 2 calls to pager or cellular telephone 3 calls to pager or cellular telephone 4 calls to pager or cellular telephone
[8]
Pager Format Transmission Options OFF
Disabled
Disabled
Programmable
Disabled
Continue after 4 sec.
see table
see table ON
Enabled
Enabled
All Codes (automatic)
Enabled
Hang-up after 16 sec.
see table
see table
Transmit report code after Pager delay
Transmit report code immediately Spectra 1759MG - 14 - Programming Guide Bold = Default Setting Section [137]: Event Call Direction Option
[1]
[2]
[3]
[4]
[5]
[6]
Call Telephone #1 for Arming/Disarming Report Codes Call Telephone #2 for Arming/Disarming Report Codes Call Telephone #1 for Alarm/Restore Report Codes Call Telephone #2 for Alarm/Restore Report Codes Call Telephone #1 for Tamper/Restore Report Codes Call Telephone #2 for Tamper/Restore Report Codes
[7] & [8] Future use Section [138]: Event Call Direction Option
[1]
[2]
[3]
[4]
Call Telephone #1 for Trouble/Restore Report Codes Call Telephone #2 for Trouble/Restore Report Codes Call Telephone #1 for Special Report Codes Call Telephone #2 for Special Report Codes
[5] to [8] Future use Communication Settings Section #
[140]
___ / ___ TEL1 TEL2 OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
N/A OFF
Disabled
Disabled
Disabled
Disabled
N/A ON
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
N/A ON
Enabled
Enabled
Enabled
Enabled
N/A REPORTING FORMATS 1 = ADEMCO SLOW (1400HZ, 1900HZ, 10BPS) 2 = SILENT KNIGHT FAST (1400HZ, 1900HZ, 20BPS) 3 = SESCOA (2300HZ, 1800HZ, 20BPS) 4 = ADEMCO EXPRESS (DTMF 4+2) 5 = ADEMCO CONTACT ID (DEFAULT) see option [3] in section [136] on page 14 6 = PAGER FORMAT If Hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports Hexadecimals. If the pager does not support Hexadecimals, use only the digits 0 to 9.
[141]
[142]
[143]
[144]
[150]
[151]
[152]
[153]
___/___/___/___ PANEL IDENTIFIER (WINLOAD SOFTWARE) ___/___/___/___ PC PASSWORD (WINLOAD SOFTWARE) ___/___/___/___ PARTITION ACCOUNT NUMBER 1 (For less than 4 digits, use the [FORCE] key to enter blanks.) ___/___/___/___ PARTITION ACCOUNT NUMBER 2 (For less than 4 digits, use the [FORCE] key to enter blanks.) __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ PC TELEPHONE NUMBER FOR WINLOAD SOFTWARE (32-digits, if less than 32 press [ENTER] to accept) __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ CENTRAL STATION TELEPHONE OR PAGER NUMBER 1 (32-digits, if less than 32 press [ENTER] to accept) __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ CENTRAL STATION TELEPHONE OR PAGER NUMBER 2 (32-digits, if less than 32 press [ENTER] to accept) __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ BACK UP TELEPHONE NUMBER (32-digits, if less than 32 press [ENTER] to accept)
[STAY] = *
[BYP] = #
[MEM] = Switch from pulse to tone dialing or vice versa
[TBL] or [TRBL] = 4-second pause
[FORCE] = Delete current digit
[PG] or [FNC1] = Inserts Blank Space Special Keys for Telephone Numbers Spectra 1759MG - 15 - Programming Guide Report Codes Ademco Slow, Silent Knight, SESCOA, Ademco Express and Pager Formats: Enter the desired 1- or 2-digit hex-value
(0-F or 00-FF). Ademco Programmable Format: Enter the desired 2-digit hex values from the Ademco Report Code List
- Programmable (see Appendix A on page 30). Also Note that entering FF will set the report code to the default Ademco Report Code. Ademco All Codes Format: The control panel automatically generates report codes from the Ademco Report Code List - All Codes (see Appendix B on page 31). Arming Report Codes
[160]___/___Access Code 01 ___/___Access Code 02 ___/___Access Code 03 ___/___Access Code 04
[165]___/___Access Code 21 ___/___Access Code 22 ___/___Access Code 23 ___/___Access Code 24
[170]___/___Access Code 41 ___/___Access Code 42 ___/___Access Code 43 ___/___Access Code 44
[161]___/___Access Code 05 ___/___Access Code 06 ___/___Access Code 07 ___/___Access Code 08
[162]___/___Access Code 09 ___/___Access Code 10 ___/___Access Code 11 ___/___Access Code 12
[163]___/___Access Code 13 ___/___Access Code 14 ___/___Access Code 15 ___/___Access Code 16
[164]___/___Access Code 17 ___/___Access Code 18 ___/___Access Code 19 ___/___Access Code 20 Disarming Report Codes
[174]___/___Access Code 01 ___/___Access Code 02 ___/___Access Code 03 ___/___Access Code 04
[175]___/___Access Code 05 ___/___Access Code 06 ___/___Access Code 07 ___/___Access Code 08
[176]___/___Access Code 09 ___/___Access Code 10 ___/___Access Code 11 ___/___Access Code 12
[177]___/___Access Code 13 ___/___Access Code 14 ___/___Access Code 15 ___/___Access Code 16
[178]___/___Access Code 17 ___/___Access Code 18 ___/___Access Code 19 ___/___Access Code 20
[166]___/___Access Code 25 ___/___Access Code 26 ___/___Access Code 27 ___/___Access Code 28
[167]___/___Access Code 29 ___/___Access Code 30 ___/___Access Code 31 ___/___Access Code 32
[168]___/___Access Code 33 ___/___Access Code 34 ___/___Access Code 35 ___/___Access Code 36
[169]___/___Access Code 37 ___/___Access Code 38 ___/___Access Code 39 ___/___Access Code 40
[179]___/___Access Code 21 ___/___Access Code 22 ___/___Access Code 23 ___/___Access Code 24
[180]___/___Access Code 25 ___/___Access Code 26 ___/___Access Code 27 ___/___Access Code 28
[181]___/___Access Code 29 ___/___Access Code 30 ___/___Access Code 31 ___/___Access Code 32
[182]___/___Access Code 33 ___/___Access Code 34 ___/___Access Code 35 ___/___Access Code 36
[183]___/___Access Code 37 ___/___Access Code 38 ___/___Access Code 39 ___/___Access Code 40
[171]___/___Access Code 45 ___/___Access Code 46 ___/___Access Code 47 ___/___Access Code 48 Special Arming Codes
[172]___/___Auto-Arming ___/___Late to Close ___/___No Movement ___/___Partial Arming
[173]___/___Quick Arming ___/___Arming via PC ___/___Keyswitch Arming ___/___Closing Delinquency
[184]___/___Access Code 41 ___/___Access Code 42 ___/___Access Code 43 ___/___Access Code 44
[185]___/___Access Code 45 ___/___Access Code 46 ___/___Access Code 47 ___/___Access Code 48 Special Disarming Codes
[186]___/___Cancel Auto-Arm ___/___Disarming via PC ___/___Keyswitch Disarm ___/___N/A Spectra 1759MG - 16 - Programming Guide Alarm Report Codes Alarm
[187]___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04
[188]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08
[189]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12
[190]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___N/A Tamper Report Codes
[197]
Trouble ___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04
[198]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08
[199]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12 Restore
[191]___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04
[192]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08
[193]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12
[194]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___N/A
[200]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___N/A
[201]
Restore ___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04
[202]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08 Special
[195]___/___Emergency Panic ___/___Auxiliary Panic ___/___Fire Panic ___/___Recent Closing
[196]___/___Zone Shutdown ___/___Duress ___/___Keypad Lockout ___/___N/A
[203]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12
[204]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___N/A System Trouble Report Codes System Trouble Restore Special
[205]___/___N/A ___/___AC Failure ___/___Battery Failure ___/___Auxiliary Supply
[208]___/___TLM ___/___AC Failure ___/___Battery Failure ___/___Auxiliary Supply
[211]___/___Cold Start (Shutdown) ___/___Test Report ___/___N/A ___/___PC Exit
[206]___/___Bell Output Overload ___/___Bell Output Disconnect ___/___Timer Loss ___/___Fire Loop Trouble
[209]___/___Bell Output Overload ___/___Bell Output Disconnect ___/___Timer Loss ___/___Fire Loop Trouble
[212]___/___Installer In ___/___Installer Out ___/___N/A ___/___N/A
[207]___/___Wireless Low Battery ___/___Module Fault ___/___Printer Fault ___/___Fail to Communicate
[210]___/___Wireless Low Battery ___/___Module Fault ___/___Printer Fault ___/___Fail to Communicate
[213]___/___TX Supervision Loss ___/___TX Supervision Restore ___/___N/A ___/___N/A Spectra 1759MG - 17 - Programming Guide System Settings Section #
Description
[280]
[281]
[282]
[301]
___/___:___/___ ___/___/___/___/___/___ ___/___/___ ___/___/___/___/___/___ SYSTEM REAL TIME CLOCK (HH:MM) INSTALLER CODE, DEFAULT: 0000 / 000000 INSTALLER CODE LOCK, DEFAULT: 000 (147 TO LOCK, 000 TO UNLOCK) SYSTEM MASTER CODE, DEFAULT: 1234 / 123456 User Code Options System Master Code arms or disarm partitions using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions. Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. Default for all user codes is options [1], [3] and [4] ON. ON = Option Enabled OFF = Option Disabled
[1] ON = Partition 1 Access
[2] ON = Partition 2 Access
[3] ON = Bypass Programming
[4] ON = Stay Arming
[5] ON = Force Arming
[6] ON = Arm Only
[7] ON = PGM Activation Only
[8] ON = Future Use Section #
[302] Master Code 1
[303] Master Code 2
[304] User Code 004
[305] User Code 005
[306] User Code 006
[307] User Code 007
[308] User Code 008
[309] User Code 009
[310] User Code 010
[311] User Code 011
[312] User Code 012
[313] User Code 013
[314] User Code 014
[315] User Code 015
[316] User Code 016
[317] User Code 017
[318] User Code 018
[319] User Code 019
[320] User Code 020
[321] User Code 021
[322] User Code 022
[323] User Code 023
[324] User Code 024 User Code Options (ON/OFF) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Section
[325]
[326]
[327]
[328]
[329]
[330]
[331]
[332]
[333]
[334]
[335]
[336]
[337]
[338]
[339]
[340]
[341]
[342]
[343]
[344]
[345]
[346]
[347]
[348]
User Code 025 User Code 026 User Code 027 User Code 028 User Code 029 User Code 030 User Code 031 User Code 032 User Code 033 User Code 034 User Code 035 User Code 036 User Code 037 User Code 038 User Code 039 User Code 040 User Code 041 User Code 042 User Code 043 User Code 044 User Code 045 User Code 046 User Code 047 User Code 048 User Code Options (ON/OFF) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Spectra 1759MG - 18 - Programming Guide Reprogram All Modules
[750]
After removing an expansion module from the communication bus, the control panel keeps the modules programmed sections in memory. Therefore, if you add or replace a module you can re-program the module with the settings saved in the control panel. To do so, enter section [750] and press [ENTER]. The keypads will beep twice every second until the procedure is completed. Paradox Memory Key (PMC-3)
[900]
[902]
DOWNLOAD FROM PARADOX MEMORY KEY TO DESTINATION CONTROL PANEL. COPY TO MEMORY KEY FROM SOURCE CONTROL PANEL. Download to DESTINATION Control Panel 1) Remove AC and battery power from the control panel. 2) Insert the Memory Key onto the serial connector labelled KEY on the Spectra control panel to which you wish to download the contents of the memory key to. 3) Re-apply AC and battery power. 4) Enter installer programming mode, enter section [900], then press [ENTER] to acknowledge. 5) When the keypad emits a confirmation beep, remove the Memory Key. 6) Enter section [750] to reprogram the modules with the information downloaded from the Paradox Memory Key. Copy to Memory Key from SOURCE Control Panel 1) Remove AC and battery power from the control panel. 2) Insert Memory Key onto the serial connector labelled KEY on the Spectra control panel that you want to copy. Make sure the write protect jumper of the Memory Key is on. 3) Re-apply AC and battery power. 4) Enter installer programming mode, enter section [902], then press [ENTER] to acknowledge. 5) When the keypad emits a Confirmation Beep, remove the Memory Key. Remove the Memory Keys jumper if you do not wish to accidentally overwrite its contents. Paradox Memory Key PMC-3 Jumper OFF =
Write protected (read from memory key only) Jumper ON =
Read from and/or write to memory key Insert Paradox Memory Key onto the MEMORY KEY connector. Partial view of Spectra 1759MG control panel Spectra 1759MG - 19 - Programming Guide 4-PGM Output Modules V2.0 Due to the APR3-PGM4s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PGM4 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PGM4 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting Section [500]: General Options Option
[1]
[2]
[3]
[4]
PGM1 Time Base Selection PGM2 Time Base Selection PGM3 Time Base Selection PGM4 Time Base Selection
[5] to [8] Future use OFF
Seconds
Seconds
Seconds
Seconds
N/A ON
Minutes
Minutes
Minutes
Minutes
N/A PGM Programming Each PGM Deactivation event can be used as another activation event if their respective PGM timer (see sections [501] to
[504]) is programmed with a value other than 000. The APR3-PGM4 uses the same PGM events as the Spectra control panel, please refer to Programmable Outputs on page 9. Decimal Value (000-255) Section #
[501] ___/___/___ (000 = follow deactivation event)
[502] ___/___/___ (000 = follow deactivation event)
[503] ___/___/___ (000 = follow deactivation event)
[504] ___/___/___ (000 = follow deactivation event) Description PGM1 TIMER PGM2 TIMER PGM3 TIMER PGM4 TIMER Default Value 5 sec. 5 sec. 5 sec. 5 sec. Section #
[505] PGM1 Activation Event
[506] PGM1 Deactivation Event
[507] PGM2 Activation Event
[508] PGM2 Deactivation Event
[509] PGM3 Activation Event
[510] PGM3 Deactivation Event
[511] PGM4 Activation Event
[512] PGM4 Deactivation Event Event Group # Sub-Group #
___/___ ___/___ ___/___ ___/___ Partition #
___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ Spectra 1759MG - 20 - Programming Guide Printer Module V2.0 Due to the APR3-PRT1s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PRT1 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PRT1 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting Section [550]: General Options Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Assigned to Partition 1 Assigned to Partition 2 PGM normal state Print Arming and disarming events Print Alarm and Alarm Restore events Print Tamper and Tamper Restore events Print Trouble and Trouble Restore events Print Special events Section [551]: Automatic Zone Status Printing Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Print status of Zone 1 Print status of Zone 2 Print status of Zone 3 Print status of Zone 4 Print status of Zone 5 Print status of Zone 6 Print status of Zone 7 Print status of Zone 8 Section [552]: Automatic Zone Status Printing Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Print status of Zone 9 Print status of Zone 10 Print status of Zone 11 Print status of Zone 12 Print status of Zone 13 Print status of Zone 14 Print status of Zone 15 N/A OFF
Disabled
Disabled
Normally Open (N.O.)
Disabled
Disabled
Disabled
Disabled
Disabled ON
Enabled
Enabled
Normally Closed (N.C.)
Automatically
Automatically
Automatically
Automatically
Automatically OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
N/A ON
Automatically
Automatically
Automatically
Automatically
Automatically
Automatically
Automatically
Automatically ON
Automatically
Automatically
Automatically
Automatically
Automatically
Automatically
Automatically
N/A Spectra 1759MG - 21 - Programming Guide Bold = Default Setting Section [553]: Serial and Parallel Port Setup Options Option
[1]
[2]&[3]
Serial port Baud Rate Settings
[2]
OFF ON OFF ON
[3]
OFF OFF ON ON APR-PRT1 1200 baud (default) 2400 baud 9600 baud 19200 baud APR3-PRT1 2400 baud (default) 9600 baud 19200 baud 57600 baud
[4]
[5]
[6]
[7]
[8]
Parallel port Off-line status ignored (parallel port only) Paper empty status ignored (parallel port only) Printer fault status ignored (parallel port only) Printer busy status ignored (parallel port only) OFF
Disabled
see table
see table
Disabled
Disabled
Disabled
Disabled
Disabled ON
Enabled
see table
see table
Enabled
Enabled
Enabled
Enabled
Enabled PGM Programming The PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to Programmable Outputs on page 9. Section #
[554] ___/___/___ seconds (000 = follow deactivation event) Decimal Value (000-255) Description PGM1 TIMER Default Value 5s Section #
[555] PGM1 Activation Event
[556] PGM1 Deactivation Event Event Group # Sub-Group #
___/___ ___/___ ___/___ ___/___ Partition #
___/___ ___/___ Clock Programming For example, to enter the date March 26, 2004 you would enter 2004 (year), 03 (month), and 26 (day). Section #
[557]
Value Year ___/___/___/___ Month ___/___ Day ___/___ Spectra 1759MG - 22 - Programming Guide Voice-assisted Arm/Disarm Bus Module V2.0 Due to InTouchs Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panels. When connected to the bus, InTouch automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one InTouch can be connected to each Spectra control panel. APR3-ADM2 can also be programmed using the WinLoad Software. Refer to the WinLoad Online Help for more information. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Decimal Value (000-255) Section #
[575] ___/___/___ rings (000 = disabled)
[576] ___/___/___ seconds (010-255, 000 = disabled)
[577] ___/___/___ seconds/minutes (000 = disabled) Description NUMBER OF RINGS ANSWERING MACHINE OVERRIDE 000 PGM TIMER 005 Default Value 8 rings Bold = Default Setting Section [578]: General Options Option
[1]
[2]
[3]
[4]
Stand-alone Code length Partitioned system PGM output PGM time in
[5] to [8] Future use OFF
6-digits
Disabled
Disabled
Seconds
N/A ON
4-digits
Enabled
Enabled
Minutes
N/A Spectra 1759MG - 23 - Programming Guide Wireless Features Do not cut, bend or alter 1759MGs antennae and ensure that electrical wires do not cross over the antennae, as this may affect signal reception. Zone Assignment The serial number can be located on the inside of the transmitter or you can use the Serial Number Display feature (see page 24). Also, refer to Zone Recognition Table on page 6. Section #
[601] ___/___/___/___/___/___= EXPANSION INPUT 1 Serial #
[602] ___/___/___/___/___/___= EXPANSION INPUT 2
[603] ___/___/___/___/___/___= EXPANSION INPUT 3
[604] ___/___/___/___/___/___= EXPANSION INPUT 4
[605] ___/___/___/___/___/___= EXPANSION INPUT 5
[606] ___/___/___/___/___/___= EXPANSION INPUT 6
[607] ___/___/___/___/___/___= EXPANSION INPUT 7
[608] ___/___/___/___/___/___= EXPANSION INPUT 8 Bold = Default Setting Section [610]: General Options Option
[1]
[2]
[3] to [7]
[8]
Wireless transmitter check-in supervision Check-in supervision interval Future use Tamper Supervision OFF
Disabled
24h
N/A
Disabled ON
Enabled
80min
N/A
Enabled Serial Number Display Section #
[630]
Description Press the anti-tamper switch of the Magellan Wireless Transmitter. The keypad will emit a confirmation beep. On LED keypads, press the [ENTER] key to view the digits one at a time. On LCD keypads, the first 3 digits of the serial number will appear. Press the [ENTER] key 3 times to view the next 3 digits. Continue activating the desired transmitters or press [CLEAR] to exit. Signal Strength Display Section #
Description After entering the desired section, activate the Magellan Wireless Transmitter by opening/closing the zone or by pressing the anti-tamper switch. Always ignore the first reading as it wont be accurate. An average reading of 3 or higher is acceptable. Display Signal Strength of Expansion Input 1 - Section [601]
Display Signal Strength of Expansion Input 2 - Section [602]
Display Signal Strength of Expansion Input 3 - Section [603]
Display Signal Strength of Expansion Input 4 - Section [604]
Display Signal Strength of Expansion Input 5 - Section [605]
Display Signal Strength of Expansion Input 6 - Section [606]
Display Signal Strength of Expansion Input 7 - Section [607]
Display Signal Strength of Expansion Input 8 - Section [608]
[631]
[632]
[633]
[634]
[635]
[636]
[637]
[638]
Spectra 1759MG - 24 - Programming Guide Remote Control User Assignment Section #
[701]
[702]
[703]
[704]
[705]
[706]
[707]
[708]
Decimal Value ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #)
* refer to Remote Control Assignment on page 26. Description remote control #1 - section [731]*
remote control #2 - section [732]*
remote control #3 - section [733]*
remote control #4 - section [734]*
remote control #5 - section [735]*
remote control #6 - section [736]*
remote control #7 - section [737]*
remote control #8 - section [738]*
Default Value 000 000 000 000 000 000 000 000 Button Options MG-REM1 Button Options Table Empty Slot [FORCE] - Button disabled 1 - Regular arming 2 - Stay arming 3 - Instant arming 4 - Force arming 5 - Disarm 6 - Disarm when no alarm 7 - Regular arm and disarm 8 - Panic 1 9 - Panic 2 A - Panic 3 B - PGM Activation (Event Group #7, see PGM Programming) C - PGM Activation (Event Group #8, see PGM Programming) D - PGM Activation (Event Group #9, see PGM Programming) Please note that the User Code assigned to the remote control (sections [701] to [708]) must have the same User Options and Button Options enabled. For example, if you enable the Force Arming button option you must enable the appropriate Force Arming user option. Also, if you enable any of the Panic button options, you must enable the Panic options in the control panel. Remote Control Button Programming RC#
Section RC Buttons Default: ( 1 5 0 0 0 0 0 0 ) 1 2 3 4 5 6 7 8
[711]
[712]
[713]
[714]
[715]
[716]
[717]
[718]
= These button combinations are not available with the MG-REM1or MG-RAC1 remote controls and cannot be programmed. Spectra 1759MG - 25 - Programming Guide Remote Control Assignment Enter the appropriate section and press any button on the remote control twice to assign the remote control. If you hear a rejection beep, an error has occurred or the remote control has already been assigned. To delete a remote control, enter the desired section and then press the [FORCE] button. Section #
[731]
[732]
[733]
[734]
[735]
[736]
[737]
[738]
REMOTE CONTROL #1 REMOTE CONTROL #2 REMOTE CONTROL #3 REMOTE CONTROL #4 REMOTE CONTROL #5 REMOTE CONTROL #6 REMOTE CONTROL #7 REMOTE CONTROL #8 Spectra 1759MG - 26 - Programming Guide Zone Expansion Bus Modules Only one SPC/APR3-ZX4 or one SPC/APR3-ZX8 can be connected to each Spectra control panel. The following sections are for SPC-ZX4 version 1.0, APR3-ZX4 version 1.0, SPC-ZX8 version 1.0 and APR3-ZX8 version 2.0. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting Section [650]: Options Option
[1]
[2]
[3]
EOL (end-of-line) resistors for hardwire modules Zone Expansion Module tamper recognition PGM1 on SPC/APR3-ZX8 follows Global PGM programmed in sections [124] & [125]
[4] to [8] Future Use Section [651]: Zone Assignment Option See Zone Recognition Table on page 6.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Input Z1
=Expansion Input 1 Input Z2
=Expansion Input 2 Input Z3
=Expansion Input 3 Input Z4
=Expansion Input 4 Input Z5 (SPC/APR3-ZX8 only) =Expansion Input 5 Input Z6 (SPC/APR3-ZX8 only) =Expansion Input 6 Input Z7 (SPC/APR3-ZX8 only) =Expansion Input 7 Input Z8 (SPC/APR3-ZX8 only) =Expansion Input 8 OFF
No EOL
Disabled
Disabled
N/A OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled ON
Use EOL Resistors
Z1 becomes tamper input
Enabled
N/A ON
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled PGM Programming (SPC-ZX8 and APR3-ZX8 Only) The PGM will only activate or deactivate 100mS after the selected event occurs. The PGM Deactivation event can be used as another activation event if the PGM Timer (section [655]) is programmed with a value other than 000. The system will ignore the PGM if it has been programmed to follow the Global PGM (option [3] in section [650]). Only PGM events from the table below can be used. Section #
[655] ___/___/___ seconds (000 = follow deactivation event) Decimal Value (000-255) Description PGM1 TIMER Default Value 5 sec. Section #
[656] PGM1 Activation Event
[657] PGM1 Deactivation Event Event Group # Sub-Group #
___/___ ___/___ ___/___ ___/___ Partition #
___/___ ___/___ Event Group #
For SPC-ZX8:
60 = Hardwire Zone Opened 61 = Hardwire Zone Closed 62 = Hardwire Tamper Opened 63 = Hardwire Tamper Closed For APR3-ZX8:
60 = Hardwire Zone/Hardwire Tamper Opened 61 = Hardwire Zone/Hardwire Tamper Closed Sub-Group #
01 = Expansion Input 1 - Section [651] - [1]
02 = Expansion Input 2 - Section [651] - [2]
03 = Expansion Input 3 - Section [651] - [3]
04 = Expansion Input 4 - Section [651] - [4]
05 = Expansion Input 5 - Section [651] - [5]
06 = Expansion Input 6 - Section [651] - [6]
07 = Expansion Input 7 - Section [651] - [7]
08 = Expansion Input 8 - Section [651] - [8]
99 = Any zone expansion bus module input Spectra 1759MG - 27 - Programming Guide Partition #
Not used; enter 00 User Operation Partitioning The Spectra system is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an office/warehouse building. If the system is not partitioned, all User Codes and features will be recognized as belonging to Partition 1. How does a partitioned system work?
Users can only arm or disarm their assigned partitions. Only zones assigned to Partition 1 will arm or disarm when Partition 1 is armed or disarmed. Only zones assigned to Partition 2 will arm or disarm when Partition 2 is armed or disarmed. Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms. Some of the systems features can be programmed separately for each partition. Programming Access Codes User Access Codes are personal identification numbers that allow users to enter certain programming modes, arm or disarm the alarm system as well as activate or deactivate PGMs. Spectra security systems support the following:
System Master Code can arm or disarm any partition using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions. Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. 45 User Access Codes (including 1 Duress code) How Do I Program Access Codes?
1) Press [ENTER]
2) Key in the [SYSTEM MASTER CODE] or [MASTER CODE]
3) Key in 3-digit [SECTION] (see User Code Table) 4) Key in new 4- or 6-digit [ACCESS CODE]
[ENTER] flashes. Return to step 3 How Do I Delete Access Codes?
1) Repeat steps 1 to 3 (see above) 2) Press the [FORCE] key once for each digit in the access code (4 or 6 times) until the keypad emits a Confirmation Beep. User Code Table User Codes Section
[001]
User Code 001 = System Master Code
[002]
User Code 002 = Master Code 1
[003]
User Code 003 = Master Code 2
[004] TO [047] User Code 004 to User Code 047
[048]
User Code 048 or Duress Code Spectra 1759MG - 28 - Programming Guide Programming Chime Zones This feature allows users to program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent beep tone (BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be Chime Programmed separately. Keypad chimes must be re-programmed if the system suffers a total power loss (16-zone LED and LCD Keypads only). 10-Zone LED Keypad Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and hold the [1] key to enable chiming on zone 1. If, after pressing and holding a key, the keypad emits a confirma-
tion beep, this means the chime feature has been enabled for that zone. If the keypad emits a Rejection Beep, this means the Chime feature has been disabled for the corresponding zone. 16-Zone LED Keypad Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s). When the corresponding LED is on, the zone is chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [ENTER]. LCD Keypad Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s) or use the arrow keys to scroll through the zones. When the appropriate zone is displayed, press the [FNC1] key. When the desired zones are chimed, press [ENTER]. Keypad Muting Press and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is pressed or when the keypad emits a Rejection or Confirmation Beep. All other beep functions are disabled. Keypad Backlight (1686H and 1686V Only) The illumination level behind the keys can be modified to suit the users needs. There are four backlight levels. The [MEM] key is used to set the desired level. Each consecutive push of the [MEM] key will increase the backlight level until the maximum level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated. To change the backlight level:
How do I Modify the Backlight?
1) Press and hold the [MEM] key for 3 seconds 2) The [MEM] key will illuminate 3) Press the [MEM] key to set the desired backlight level 4) Press [CLEAR] or [ENTER] to exit Quick Function Keys Installer Test Mode
[ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]
The Installer Test Mode allows you to perform walk tests where the bell/siren will squawk once to indicate an open zone and twice to indicate a closed zone. To enter this mode, press [ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]. The keypad will emit a Confirmation Beep. To disable this mode, press the [TBL] or [TRBL] key again. The keypad will emit a Rejection Beep. Test Report
[ENTER] + [INSTALLER/MASTER CODE] + [MEM]
Sends the Test Report report code programmed in section [211] to the central station. Call WinLoad Software
[ENTER] + [INSTALLER/MASTER CODE] + [BYP]
This feature is used to establish communication between the control panel and a computer using the WinLoad Software. After entering this mode, the control panel will dial the telephone number programmed in section [150]. Cancel Communication
[ENTER] + [INSTALLER/MASTER CODE] + [STAY]
Cancels all communication until the next reportable event. If the Master Code was used, only communication with WinLoad would be cancelled. Answer WinLoad Software
[ENTER] + [INSTALLER/MASTER CODE] + [FORCE]
Forces the control panel to pick-up an incoming telephone call. Spectra 1759MG - 29 - Programming Guide Appendix A - Ademco CID Report Code List (Prog.) If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog. Value) into sections [160] to [213] to program the desired report codes. To enter a 0 value press the [FORCE] key. Prog. Value CID#
Reporting Code MEDICAL ALARMS - 100 Medical Alarm Pendant Transmitter Fail to Report In 100 101 102 110 111 112 113 114 115 116 117 118 FIRE ALARMS - 110 Fire Alarm Smoke Combustion Water Flow Heat Pull Station Duct Flame Near Alarm PANIC ALARMS - 120 Panic Alarm Duress Silent Audible 120 121 122 123 BURGLAR ALARMS - 130 130 131 132 133 134 135 136 137 138 Burglary Perimeter Interior 24-Hour Entry/Exit Day/Night Outdoor Tamper Near Alarm GENERAL ALARMS - 140 General Alarm Polling Loop Open Polling Loop Short Expansion Module Failure Sensor Tamper Expansion Module Tamper 140 141 142 143 144 145 24-HOUR NON-BURGLARY - 150 & 160 150 151 152 153 154 155 156 157 158 159 161 24-Hour Non-Burglary Gas Detected Refrigeration Loss of Heat Water Leakage Foil Break Day Trouble Low Bottled Gas Level High Temp Low Temp Loss of Air Flow FIRE SUPERVISORY - 200 & 210 200 201 202 Fire Supervisory Low Water Pressure Low CO2 CID#
203 204 205 206 Reporting Code Gate Valve Sensor Low Water Level Pump Activated Pump Failure SYSTEM TROUBLES - 300 & 310 Prog. Value 2E 2F 30 31 300 301 302 303 304 305 306 307 308 309 310 System Trouble AC Loss Low System Battery RAM Checksum Bad ROM Checksum Bad System Reset Panel Program Changed Self-Test Failure System Shutdown Battery Test Failure Ground Fault 32 33 34 35 36 37 38 39 3A 3B 3C SOUNDER/RELAY TROUBLES - 320 320 321 322 323 324 325 330 331 332 333 334 335 336 Sounder Relay Bell 1 Bell 2 Alarm Relay Trouble Relay Reversing 3D 3E 3F 40 41 42 SYSTEM PERIPHERAL TROUBLES - 330 & 340 43 44 45 46 47 48 49 COMMUNICATION TROUBLES - 350 & 360 4A 4B 4C 4D 4E 4F 50 Communication Telco Fault 1 Telco Fault 2 Long Range Radio Fail to Communicate Loss of Radio Supervision Loss of Central Polling System Peripheral Polling Loop Open Polling Loop Short Exp. Module Failure Repeater Failure Local Printer Paper Out Local Printer Failure 350 351 352 353 354 355 356 PROTECTION LOOP TROUBLES - 370 370 371 372 373 Protection Loop Protection Loop Open Protection Loop short Fire Trouble SENSOR TROUBLES - 380 Sensor Trouble Loss of Super. -RF Loss of Super. - RPM Sensor Tamper RF xmtr. Low Battery 380 381 382 383 384 OPEN/CLOSE - 400 400 Open/Close 51 52 53 54 55 56 57 58 59 5A CID#
401 402 403 404 405 406 407 408 409 Reporting Code O/C by User Group O/C Automatic O/C Late to O/C Deferred Cancel Remote Arm/Disarm Quick Arm Keyswitch O/C Prog. Value 5B 5C 5D 5E 5F 60 61 62 63 REMOTE ACCESS - 410 411 412 413 414 415 Callback Request Made Success - Download Access Unsuccessful Access System Shutdown Dialer Shutdown 421 422 ACCESS CONTROL - 420 Access Denied Access Report By User SOUNDER RELAY DISABLES - 520 Sounder/Relay Disabled Bell 1 Disable Bell 2 Disable Alarm Relay Disable Trouble Relay Disable Reversing Relay Disable 520 521 522 523 524 525 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 COMMUNICATION DISABLES - 550 & 560 551 552 Dialer Disabled Radio xmitter Disabled BYPASSES - 570 570 571 572 573 574 Zone Bypass Fire Bypass 24-Hour Zone Bypass Burg. Bypass Group Bypass TEST/MISC. - 600 601 602 603 604 605 606 607 621 622 623 624 625 626 627 628 631 654 Manual Trigger Test Periodic Test Report Periodic RF Xmission Fire Test Status Report to Follow Listen-in to Follow Walk Test Mode Event Log Reset Event Log 50% Full Event Log 90% Full Event Log Overflow Time/Date Reset Time/Date Inaccurate Program Mode Entry Program Mode Exit Exception Schedule Change System Inactivity 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 Spectra 1759MG - 30 - Programming Guide 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D Appendix B - Ademco CID Report Code List (All Codes) 1 4A1 - Open by user Auxiliary supply trouble restore 3 3AA - System trouble restore 1 4A9 - Keyswitch Open Bell output current limit restore 3 321 - Bell 1 restore System Event Auxiliary supply trouble Bell output current limit Bell absent Clock lost Fire loop trouble Wireless Transmitter Low Battery Wireless Transmitter Supervision Loss Module fault Printer fault Fail to communicate with central station Wireless Transmitter Low Battery TLM trouble restore AC Failure restore Battery Failure restore Default Contact ID Report Code when option [3] is on in section [136]
1 3AA - System trouble 1 321 - Bell 1 1 321 - Bell 1 1 626 - Time/Date inaccurate 1 373 - Fire trouble 1 384 - RF xmtr. low battery 1 381 - Loss of super. - RF 1 333 - Expansion module failure 1 336 - Local printer failure 1 354 - Fail to communicate 1 384 - RF xmtr. low battery 3 351 - Telco 1 fault restore 3 3A1 - AC loss restore 3 3A9 - Battery test restore Bell absent restore Clock programmed Fire loop trouble restore Wireless Transmitter Low Battery Wireless Transmitter Supervision Loss Module fault restore Printer fault restore Fail to communicate with central station 3 321 - Bell 1 restore 3 626 - Time/Date Reset 3 373 - Fire trouble restore 3 384 - RF xmtr. low battery 3 381 - Loss of super. - RF 3 333 - Expansion module failure restore 3 336 - Local printer failure restore 3 354 - Fail to communicate restore Cold Start Test Report engaged PC software communication finished Installer on site Installer programming finished Delinquency 1 3A8 - System shutdown 1 6A2 - Periodic test report 1 412 - Successful - download access 1 627 - Program mode Entry 1 628 - Program mode Exit 1 654 - Inactivity System Event Arming with Master Code (##) Arming with User Code (##) Arming with Keyswitch (##) Auto Arming Arm with PC software Late To Close Default Contact ID Report Code when option [3] is on in section [136]
3 4A1 - Close by user 3 4A1 - Close by user 3 4A9 - Keyswitch Close 3 4A3 - Automatic Close 3 4A7 - Remote arm/disarm 3 4A4 - Late to Close No Movement Partial arming Quick arming 3 4A4 - Late to Close 1 574 - Group bypass 3 408 - Quick arm Disarm with Master Code (##) 1 4A1 - Open by user Disarm with User Code (##) Disarm with Keyswitch (##) Disarm after alarm with Master Code (##) Disarm after alarm with User Code (##) Disarm after alarm with Keyswitch (##) Auto Arming Cancellation Disarm with PC software Disarm after an alarm with PC software 1 4A1 - Open by user 1 4A9 - Keyswitch Open 1 4A1 - Open by user 1 4A5 - Deferred Open/Close 1 4A7 - Remote arm/disarm 1 4A7 - Remote arm/disarm Zone Bypassed (##) 1 57A - Zone bypass Zone alarm (##) Fire alarm (##) 1 13A - Burglary Alarm 1 11A - Fire alarm Zone alarm restore (##) Fire alarm restore (##) 3 13A - Burglary Alarm Restore 3 11A - Fire alarm Restore Panic 1 - Emergency 1 12A - Panic alarm Panic 2 - Medical Panic 3 - Fire Recent closing Global zone shutdown Duress alarm Zone shutdown (##) 1 1AA - Medical alarm 1 115 - Pull Station 3 4AA - Open/Close 1 574 - Group bypass 1 121 - Duress 1 57A - Zone bypass Zone tampered (##) Zone tamper restore (##) 1 144 - Sensor tamper 3 144 - Sensor tamper restore AC Failure Battery Failure 1 3A1 - AC loss 1 3A9 - Battery test failure Spectra 1759MG - 31 - Programming Guide Bus Module Connections Press the PRINT TEST switch to perform a print test C RX LED reserved for future use Printer Module (APR3-PRT1) A B Spectra 1759MG Control Panel Not Used Communication Bus D E F Connecting the PGM Output A Green Locate LED: Remains illuminated during power up B Red Watchdog LED: Flashes to indicate proper operation. If there is a communication failure, the red LED will flash ON for one second and OFF for one second. C Red TX LED: Flashes when the Printer Module is transmitting data through the serial port only. D 25-pin Parallel Port: Connect the Printer Modules 25-pin parallel port to any dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns. E 9-Pin Serial Port: Connect the Printer Modules 9-Pin serial port to a dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns. F 9-Pin Serial Port: Connect the Printer Modules 9-Pin serial port to a computers COM port to view the control panels events on the computers monitor. The events displayed on the monitor can then be printed through the printer connected to the computer. Remove AC power and battery before adding APR3-PRT1 to the system. Do not connect any modules more than 76m (250ft) from the control panel. Only one Printer Module can be connected per Spectra control panel. Spectra 1759MG - 32 - Programming Guide 4-PGM Output Module (APR3-PGM4) Red Watchdog LED:
Status: flashes once per second to indicate proper operation. Flash 1 second on and 1 second off: The module is experiencing a communication failure with the control panel. To Spectra 1759MG control panel Not Used External Power Supply
(Recommended: Paradox PSW817 1.75A Switching Power Supply) Communication Bus Any device such as a garage door opener, light or siren Remove AC and battery from the control panel before adding the 4-PGM Output Module to the system. Do not connect the APR3-PGM4 more than 76m (250ft) from the control panel. Only one APR3-PGM4 can be connected per Spectra control panel. 4-zone expansion Bus Module (SPC-ZX4 and APR3-ZX4) Not Used Red WDG LED:
Status = Flashes to indicate proper operation. Flash 1 sec. on & 1 sec. off = Trouble and/or communication failure. Connecting the Anti-
Tamper Switch Not Used Spectra 1759MG control panel Communication Bus Connect the detection devices to the module's input terminals exactly as shown in the Spectra 1759MG Reference &
Installation Manual. Input terminal Z1 can be used as an anti-tamper switch input Option [2]: Section [650]
Remove AC and battery power from the control panel before connecting the module to the communication bus. Do not connect the APR3-ZX4 or SPC-ZX4 more than 76m (250ft) from the control panel. Only one APR3-ZX4 or one SPC-ZX4 can be connected per Spectra control panel. Spectra 1759MG - 33 - Programming Guide Voice-assisted Arm/Disarm Bus Module (APR3-ADM2) Remove AC and battery power from the control panel before adding the APR3-ADM2 module to the system. Do not connect the APR3-ADM2 more than 76m (250ft) from the control panel. Only one APR3-
ADM2 can be connected per Spectra control panel. Green "PULSE"LED:
Monitors the dialer. The LED will illuminate when the dialer is in use. When the dialer is not being used, the LED will remain off. Red WATCHDOG LED:
Flashes once every second = normal. Flashes 1 second on & 1 second off = trouble and/or communication failure. Not Used Communication Bus Ground clamp Cold water pipe grounding Refer to Inset 1 To Spectra 1759MG control panel Household telephone Spectra 1759MG Dialer Inset 1: Connecting the APR3-ADM2 PGM Output Partial view of the APR3-ADM2 External Power Supply
(Recommended: Paradox PSW817 1.75A Switching Power Supply) Any device such as a garage door opener, light or siren Spectra 1759MG - 34 - Programming Guide 8-Zone Expansion Bus Modules (SPC-ZX8 and APR3-ZX8) Not Used Red WDG LED:
Flash once every sec. = normal. Flash 1 sec. on & 1 sec. off = Trouble and/or communication failure. Inset 2 Not Used Refer to the Spectra 1759MG Reference & Installation Manual about connecting devices to the Expansion Input Terminals. Inset 1 Inset 1: Connecting the PGM output Inset 2: Anti-Tamper Switch Connection Communication Bus Spectra 1759MG control panel Input terminal Z1 can be used as an anti-tamper switch input. Option [2]: Section [650]
Remove AC power and battery before adding a module to the system. Do not connect the APR3-ZX8 or SPC-ZX8 more than 76m (250ft) from the control panel. Only one SPC-ZX8 or APR3-ZX8 can be connected per Spectra control panel. Spectra 1759MG - 35 - Programming Guide Hardware Connections Single Zone Inputs Fire Circuits 4-Wire Installation Control Panel Terminals Keyswitch PGM Connecting Fire Circuits, Keyswitches and PGMs Program the PGM with the [PG]/[FNC1] Key was pressed Activation Event so that the smoke detectors can be reset by pressing the
[PG] or [FNC1] key. See Event Group # 5 on page 9. All 4-wire smoke detectors must be connected using the daisy chain configuration. Programming a Wireless Fire Zone Fire zones cannot be assigned to expansion zones. As a result, when installing a wireless smoke detector, the corresponding zone must be programmed as follows:
1) Enter [5] in the Zone Definition to define it as a 24Hr Burglary Alarm (see page 7). 2) Disable [4] and enable [5] in Zone Options to set the zones alarm type to a pulsed Audible Alarm
(see page 7). 3) Disable [1] and [2] in Zone Options to disable the zones Auto Zone Shutdown and Bypass Enabled features (see page 7). 4) Change the zones report code from a Burglary Report Code (Prog. Value 11) to a Fire Report Code (Prog. Value 04). See Appendix A on page 30. If using Ademco Contact I.D., set the Contact ID Options from All Codes to Programmable (section [136] option [3] = OFF) and then enter the report code manually (see page 14). Spectra 1759MG - 36 - Programming Guide Alarm Relay and PGM Connections Alarm Relay (5A) can be programmed to follow the BELL output or the Global PGM External Power Supply Any device such as a strobe light or siren AUX+
External power supply PGMs When the device connected to a PGM is powered by:
AUX+ terminal =
External power supply = PGM1 cannot exceed 150mA must not exceed 700mA PGM2 cannot exceed 1A If power supply's current limit is less than that of the PGM it is connected to, then the current consumption cannot exceed the power supply's current limit. PGM2 can be used as a strobe output. Connecting More Than Two Keypads If there are more than 2 keypads connected to the control panel and at least one keypad zone is being used, connect as shown and program as described in the Spectra 1759MG Reference & Installation Manual. When a 1641 LCD keypad is connected to Spectra, the Keypad Zone Sending option (Option [2] key [1]) determines whether the status of the keypad zone will be transmitted to the control panel. Refer to the 1641 Installers Guide for more information. The Keypad Zone Sending option of the 1641 keypad must be enabled during the following conditions:
If you are using both keypad zones and at least one is from a 1641 keypad. If you are using the keypad zones of other types of keypads, such as a 1686H 10-zone LED keypad, and the keypad zone definition of the 1641 keypad (keypad zone 1 or keypad zone 2; Option [2] key [3]) matches that of another connected keypad. Do not place a jumper across the zone and BLK input terminals of the keypads that are not using their keypad zones. A Door Contact or any other detection device. 1686H
(Using keypad zone) 1686H
(Not using keypad zone) 1641 LCD Keypad
(Not using keypad zone) Be sure to enable option [1] (Keypad Zone Sending) of option [2]
(Options) in the 1641s LCD Programming Mode. AC Power & Backup Battery Connections Transformer Requirements Table Amseco XP-1620 16VAC 20VA *
1.2A Recommended: 16VAC 40VA UL: Basler BE156240CAA007 1.5A typ: 600mA max: 700mA 350mA typ: 600mA max: 700mA UL installations: typ. 200mA 350mA / 700mA Transformer:
Spectra DC Power Supply rated at:
Auxiliary Supply can provide a maximum of:
Acceptable Battery Charge Currents
(section [127] option [5])
* Not verified by UL Rechargeable Battery UL/ULC - 12Vdc / 4Ah or 7Ah Warning:
Improper connection of the transformer may result in damage to the system. Partial view of Spectra 1759MG control panel UL Warning:
A 12Vdc / 7Ah battery is required to comply with UL fire requirements. Caution:
Disconnect battery before replacing the fuse. Spectra 1759MG - 37 - Programming Guide Spectra 1759MG PCB Layout
"STATUS" LED:
Flash once every second = normal Flashes ON 1 second and OFF 1 second = trouble Always ON = panel is using phone line Fast flash 4 seconds after power up = installer lock enabled
"RX" LED:
Flashes quickly when receiving signals from wireless devices. Paradox Memory Key (PMC-3) Reset Jumper Refer to AC Power
& Backup Battery Connections on page 37. Four pin connector can be used for quick installation of a Spectra keypad or Expansion Module. To connect the 5A Alarm Relay and the PGMs, refer to Alarm Relay and PGM Connections on page 37. To connect AC power, refer to AC Power
& Backup Battery Connections on page 37. Refer to Single Zone Inputs on page 36 Antennae Warning:
Do not cut, bend or alter the antennae and ensure that electrical wires do not cross over the antennae, as this may affect signal reception. Warning:
Disconnect telephone line before servicing. AWG#14 single conductor solid copper wire Cold water pipe grounding Ground clamp The "BELL" output will shutdown if the current exceeds 3A. Communication Bus AUX Power Refer to transformer requirements on page 37 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. For the keypads zone, EOL and tamper configurations, refer to page 5. Warning:
This equipment must be installed and maintained by qualified service personnel only. To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure The maximum number of keypads per installation is dependent on the auxiliary output, which cannot exceed 700mA. Spectra Keypads A Door Contact or any other detection device can be connected to the Keypad Zone. Warning:
Do not connect keypads more than 76m (250ft) from the control panel. For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Spectra 1759MG Reference & Installation Manual. Spectra 1759MG - 38 - Programming Guide Warranty Paradox Security Systems Ltd. (Seller) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the products inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Sellers maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. 2002-2005 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply. Spectra, Digiplex and Magellan are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Fri-
day from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.ca. 780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7444 Fax: (450) 491-2313 www.paradox.ca PRINTED IN CANADA - 01/2005 1759MG-EP05
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2005-04-08 | 433.92 ~ 433.92 | CYY - Communications Receiver used w/Pt 15 Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2005-04-08
|
||||
1 | Applicant's complete, legal business name |
Paradox Security Systems
|
||||
1 | FCC Registration Number (FRN) |
0007597024
|
||||
1 | Physical Address |
780 Industriel Blvd
|
||||
1 |
Quebec, N/A J7R 5V3
|
|||||
1 |
Canada
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
s******@nemko.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
KDY
|
||||
1 | Equipment Product Code |
1759MG
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A******** C********
|
||||
1 | Title |
Certification Manager
|
||||
1 | Telephone Number |
450-4********
|
||||
1 | Fax Number |
450-4********
|
||||
1 |
a******@paradox.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Nemko Canada Inc.
|
||||
1 | Name |
R****** D******
|
||||
1 | Physical Address |
303 River Road
|
||||
1 |
Ottawa, Ontario, K1V 1H2
|
|||||
1 |
Canada
|
|||||
1 | Telephone Number |
613-7******** Extension:
|
||||
1 | Fax Number |
613-7********
|
||||
1 |
r******@nemko.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | CYY - Communications Receiver used w/Pt 15 Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Spectra 1759MG | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Nemko Canada Inc. (Ottawa)
|
||||
1 | Name |
C****** N********
|
||||
1 | Telephone Number |
613-7******** Extension:
|
||||
1 | Fax Number |
613-7********
|
||||
1 |
c******@nemko.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B | 433.92000000 | 433.92000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC