all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 2.98 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Internal Photos | |||||||
1 | RF Exposure Info | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Users Manual | Users Manual | 2.98 MiB |
Outdoor 802.11n Wireless Access Point
(P/N DA2131-V1) Owners Manual 1308197 Rev. B
- i -
Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules and RSS-210 Issue 8 of Canada. Operation is subject to the following two conditions:
This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected. Consult the dealer or an experienced radio/TV technician for help. Reprinted from the Code of Federal Regulations #47, part 15.193, 1993. Washington DC: Office of the Federal Register, National Archives and Records Administration, U.S. Government Printing Office. in the Radio Interference Regulations of Canadian Department of Communications This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out the Canadian Department of Communications. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. FCC Radio Frequency Exposure Caution Statement In order to maintain compliance with the FCC RF exposure guidelines, this equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Use only with supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. Any changes of modifications not expressly approved by the grantee of this device could void the users authority to operate the equipment. Installation and use of this Wireless LAN device must be in strict accordance with the instructions included in the user documentation provided with the product. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the
- ii -
users authority to operate the equipment. The manufacturer is not responsible for any radio or television interference caused by unauthorized modification of this device, or the substitution or attachment of connecting cables and equipment other than manufacturer specified. It is the responsibility of the user to correct any interference caused by such unauthorized modification, substitution or attachment. Manufacturer and its authorized resellers or distributors will assume no liability for any damage or violation of government regulations arising from failing to comply with these guidelines. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Declaration of Conformity (R&TTE directive 1999/5/EC) The following items were completed and are considered relevant and sufficient:
Essential requirements as in [Article 3]
Protection requirements for health and safety as in [Article 3.1a]
Testing for electric safety according to [EN 60950]
Protection requirements for electromagnetic compatibility in [Article 3.1b]
Testing for electromagnetic compatibility in [EN 301 489-1] & [EN 301]
Testing according to [489-17]
Effective use of the radio spectrum as in [Article 3.2]
Testing for radio test suites according to [EN 300 328-2]
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. THE UNIT MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING WATER. CAUTION: DO NOT OPEN THE UNIT. DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION: THIS DEVICE MUST BE INSTALLED AND USED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AS DESCRIBED IN THE USER DOCUMENTATION THAT COMES WITH THE PRODUCT. WARNING: POSTPONE INSTALLATION UNTIL THERE IS NO RISK OF THUNDERSTORM OR LIGHTNING ACTIVITY IN THE AREA. When using this device, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
Read all of the instructions {listed here and/or in the user manual} before you operate this equipment. Give particular attention to all safety precautions.
- iii -
Retain the instructions for future reference. Comply with all warning and caution statements in the instructions. Observe all warning and caution symbols that are affixed to this equipment. Comply with all instructions that accompany this equipment. Avoid using this product during an electrical storm. There may be a risk of electric shock from lightning. For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug the power supply, and disconnect the Cat 5e to the N-WAP at the POE Injector. This will prevent damage to the product due to lightning and power surges. It is recommended that the customer install an AC surge protector in the AC outlet to which this device is connected. This is to avoid damaging the equipment by local lightning strikes and other electrical surges. Operate this product only from the type of power source indicated on the products marking label. If you are not sure of the type of power supplied to your home, consult your dealer or local power company. Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in safe operating condition. Installation of this product must be in accordance with national wiring codes and conform to local regulations. Place POE Injector to allow for easy access when disconnecting the power cord/adapter of the device from the AC wall outlet. Wipe the unit with a clean, dry cloth. Never use cleaning fluid or similar chemicals. Do not spray cleaners directly on the unit or use forced air to remove dust.
- iv -
TABLE OF CONTENTS Chapter 1 Introduction ....................................................................................................................... 1 Overview ....................................................................................................................................... 1 Product Features .......................................................................................................................... 1 Package Content .......................................................................................................................... 1 Physical Details ............................................................................................................................ 2 Chapter 2 Physical Installation .......................................................................................................... 5 Physical Installation Steps .......................................................................................................... 5 Chapter 3 Network Settings ............................................................................................................. 10 Configuring and monitoring your DA2131-V1 from web browser .......................................... 10 Chapter 4 Basic System Settings .................................................................................................... 16 Setup Wizard ............................................................................................................................... 16 DHCP ........................................................................................................................................... 16 Static ........................................................................................................................................... 17 PPPOE ......................................................................................................................................... 18 L2TP ............................................................................................................................................ 19 PPTP ............................................................................................................................................ 20 Configure Wireless Settings ...................................................................................................... 22 Operation Mode .......................................................................................................................... 23 Internet Settings ......................................................................................................................... 24 LAN Settings ............................................................................................................................... 26 VPN Passthrough ....................................................................................................................... 28 Advanced Wireless Settings ..................................................................................................... 31 Security ....................................................................................................................................... 33 WDS ............................................................................................................................................. 42 Status .......................................................................................................................................... 49 Firewall ........................................................................................................................................ 52 Port Forwarding .......................................................................................................................... 53 Administration ............................................................................................................................ 57 Firmware Update ........................................................................................................................ 58 Settings Management ................................................................................................................ 59 System Log ................................................................................................................................. 61 Appendix A DA2131-V1 Specifications ..................................................................................... 62
- v -
- vi -
Owners Manual of DA2131-V1 Chapter 1 Introduction Overview The DA2131-V1 Outdoor Wireless Access Point from Legrand now extends your home networks wireless reach to locations outside the home, such as patios or pool areas. With its environmental protection, the DA2131-V1 can perform under rigorous weather conditions including heavy rain and wind. With its Power over Ethernet (PoE) design, it can be easily installed in the areas where power outlets are not available. With built-in IEEE 802.11b/g/n wireless network capability, the Outdoor N-WAP allows any computer and wireless enabled network client connect to it without additional cabling. With an 802.11n compatible wireless adapter installed in your PC, the files can be transferred at speeds up to 150Mbps. The radio coverage is also designed specifically for outdoor use. To secure the wireless communication, the Outdoor N-WAP supports the most up-to-date encryption:
64/128- bit WEP, WPA / WPA2, WPA-PSK / WPA2-PSK and 802.1x authority to secure and protect your wireless LAN. MAC filtering and SSID broadcast control are provided to consolidate the wireless network security and prevent unauthorized wireless connection. The DA2131-V1 supports multiple modes, including AP/Client, WDS Bridge and WDS Repeater. Product Features
IEEE 802.11b/g/n wireless standard compliant 10/100Mbps RJ-45 ports with auto MDI/MDI-X supported Supports 64/128-bit WEP, WPA, WPA-PSK, WPA2, WPA2-PSK and 802.1x encryption Package Content POE Injector with reset button Power Adaptor (12V, 1A) The contents of your product package should include the following items:
DA2131-V1 802.11n Outdoor Wireless Access Point
Mounting Tie x 2
Installation/Instruction Sheet A CD containing this manual.
- 1 -
Owners Manual of DA2131-V1 Physical Details The following figures illustrate the physical details of the Outdoor N-WAP. 1.1 The Rear Panel LED Wireless LAN LED Power LED LAN Port LED WAN Port LED Figure 1-1 Rear Panel LED Identification 1.2 LED Indications LED Power WLAN WAN LAN State On Off On Off Blinking On Off Blinking On Off Blinking Meaning System On System Off Wireless Radio ON. Wireless Radio Off. Data is transmitting or receiving on the wireless. Port linked. No link. Data is transmitting or receiving on the WAN interface. Port linked. No link. Data is transmitting or receiving on the LAN interface.
- 2 -
1.3 The Rear Panel Port & Connector Owners Manual of DA2131-V1 RP-SMA Connector for External Antenna (not supplied) LAN Port with PoE WAN Port with PoE Figure 1-2 Port and Connector of DA2131-V1 Figure 2-3 Port and Connector description label Interface RP-SMA Connector LAN WAN Function For external antenna. You can use the reverse SMA connector to connect a 2.4GHz external antenna (not supplied by Legrand). The RJ-45 jack allows LAN connection through a Category 5 cable. Supports auto-sensing on 10/100M speed and half/ full duplex; complys with IEEE 802.3/ 802.3u respectively. The RJ-45 jack allows WAN connection through a Category 5 cable. Supports auto-sensing on 10/100M speed and half/ full duplex; complys with IEEE 802.3/ 802.3u respectively. 1. For External Antenna Mode, you MUST physically attach antenna before powering on. 2. When using an external antenna, you should configure the Antenna Switch from Internal to External via Web UI.
- 3 -
Owners Manual of DA2131-V1 1.4 PoE Injector
PoE Module Figure 1-4 Top view of PoE Injector 3. Use only for DA2131-V1 Figure 1-5 Label of PoE Injector
PoE Reset Button Reset Button Figure 1.6 Reset Button of PoE Injector Time Push and hold the reset button of POE injector about 5 ~ 10 seconds to reset the configuration parameters to factory defaults. Active Reset
- 4 -
Owners Manual of DA2131-V1 Chapter 2 Physical Installation Physical Installation Steps 2.1 Preparation before Installation 2.1.1 Professional Installation Required Please seek assistance from a professional installer who is well trained in Wireless data product installation and knowledgeable in the local regulations. 2.1.2 Safety Precautions 1. 2. 3. To keep you safe and install the hardware properly, please read and follow these safety precautions. If you are installing the DA2131-V1 for the first time, for your safety as well as others, please seek assistance from a professional installer who has received safety training on the hazards involved. Keep safety as well as performance in mind when selecting your installation site, especially where there are electric power and phone lines. 4. When installing the DA2131-V1, please note the following things:
Do not use a metal ladder;
Do not work on a wet or windy day;
Wear shoes with rubber soles and heels, rubber gloves, long sleeved shirt or jacket. 5. When the system is operational, avoid standing directly in front of it. Strong RF fields are present when the transmitter is on. 2.1.3 Installation Precautions To avoid damage to the DA2131-V1 while you are installing it, please read and follow these installation precautions. 1. Users MUST use a proper and well-installed surge arrestor with the DA2131-V1; otherwise, a random lightening strike could easily cause fatal damage to the product. EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRNTY. 2. 3. Users MUST use the Power cord & PoE Injector shipped in the box with the DA2131-V1. Use of other options may cause damage to the product. Users MUST power off the DA2131-V1 first before connecting any external antenna to it. Do not switch from built-in antenna to the external antenna from WEB management without physically attaching the external antenna onto the device first; otherwise, damage might be caused to the DA2131-V1.
- 5 -
Owners Manual of DA2131-V1 2.2 Hardware Installation 2.2.1 Installation Steps Step 1. Push the latch in the bottom of DA2131-V1 to remove the sliding cover. Figure 2-1 Move the cover Step 2. Plug the RJ-45 Ethernet cable into the LAN Port of DA2131-V1. Figure 2-2 Cable Connection RJ-45 8P8C Ethernet cable is required.
- 6 -
Step 3. Slide the cover back to seal the bottom of the DA2131-V1. Owners Manual of DA2131-V1 Figure 2-3 Seal the bottom Step 4. Take out the AC adapter and PoE injector, plug the power cord into the DC port and plug the other side of the RJ-45 cable from STEP 2 into the POE port of the PoE injector. DC: Insert adapter DC power cord POE: This jack is connected to LAN port of the Outdoor N-WAP with the supplied Cat5 cable. LAN: This jack is connected to LAN side PC/Hub or Router/ADSL modem device with a Cat5 cable To DA2131-V1 Figure 2-4 Connect to PoE Injector
- 7 -
Step 5. Complete the hardware installation as indicated on the illustration below. Owners Manual of DA2131-V1 Figure 2-5 Cabling complete It will take about 50 seconds to complete the boot up sequence after powering on the Outdoor N-WAP; Power LED will be active, and after that the WLAN Activity LED will be flashing to show the WLAN interface is enabled and working now. To avoid lightening strike damage, consider installing a lightening arrestor between the NWAP and PoE injector.
- 8 -
Owners Manual of DA2131-V1 2.2.2 Pole Mounting Step 1. Turn the DA2131-V1 over. Feed a pole mounting tie through the middle hole of the rear structure. Step 2. Mount DA2131-V1 securely to the pole by fastening both mounting ties tightly. Step 3. Now you have completed the hardware installation of DA2131-V1 as shown in the figure below. Mounting Tie 2.2.3 Surface Mounting Figure 2-6 Pole Mounting Notice the rear bracket flange of the DA2131-V1 contains a screw hole in each corner for mounting to a flat surface with appropriate screws (provided). 2.2.4 Using an External Antenna If you prefer to use the external antenna with SMA-type connector for your application instead of the built-in directional antenna, please follow the steps below. Step 1. Connect your antenna with the SMA-type connector on the bottom of DA2132-V1. Step 2. Power on the DA2131-V1, and then go to Wireless Settings-> Basic to configure the Antenna Switch from Internal to External. If you are going to use an external antenna on DA2131-V1, get some cable in advance. 1. 2. Users MUST power off the DA2131-V1 first before connecting the external antenna to it. Do not switch from built-in antenna to the external antenna from WEB management without physically attaching the external antenna onto the DA2131-V1; otherwise, damage might be caused to the Outdoor NWAP itself.
- 9 -
Owners Manual of DA2131-V1 Chapter 3 Network Settings Configuring and monitoring your DA2131-V1 from a web browser The DA2131-V1 integrates a web-based graphical user interface that can cover most configurations and machine status monitoring. Via a standard web browser, you can configure and check machine status from anywhere around the world. NOTE: The DA2131-V1 comes from the factory with the following IP configuration:
Default IP Address: 192.168.40.252 Default IP Subnet Mask: 255.255.255.0 WEB login User Name; admin WEB login Password: admin 3.1 Connecting to the Outdoor NWAP For OS of Microsoft Windows 2000/ XP:
1. Click the Start button and select Settings, then click Control Panel. The Control Panel window will appear. 2. Move mouse and double-click the right button on Network and Dial-up Connections icon. Move mouse and double-click the Local Area Connection icon. The Local Area Connection window will appear. Click Properties button in the Local Area Connection window. Figure 3-1 3. Check the installed list of Network Components. If TCP/IP is not installed, click the Add button to install it; otherwise go to step 6.
- 10 -
Owners Manual of DA2131-V1 4. 5. Select Protocol in the Network Component Type dialog box and click Add button. Select TCP/IP in Microsoft of Select Network Protocol dialog box then click OK button to install the TCP/IP protocol, it may need the Microsoft Windows CD to complete the installation. Close and go back to Network dialog box after the TCP/IP installation. 6. Select TCP/IP and click the properties button on the Network dialog box. Figure 3-2 7. Select Specify an IP address and type in values as following example. IP Address: 192.168.40.2, or any IP address within 192.168.40.2 to 192.168.40.251 is good to connect to the Outdoor NWAP. IP Subnet Mask: 255.255.255.0
- 11 -
Owners Manual of DA2131-V1 40 2 Figure 3-3 8. Click OK to complete the IP parameters setting. For OS of Microsoft Windows Vista / 7:
1. Click the Start button and select Settings, then click Control Panel. The Control Panel window will appear. 2. Move mouse and double-click the right button on Network Connections item. The Network Connections window will appear. Double click Local Area Connection icon, then User Account Control window shown. Right click Continue button to set properties. 3. In Local Area Connection Properties window, Choose Networking tab, move mouse and click Internet Protocol Version 4 (TCP/IPv4), then click Properties button.
- 12 -
Owners Manual of DA2131-V1 Figure 3-4 4. Move mouse and click General tab, Select Specify an IP address and type in values as following example. IP Address: 192.168.40.2, or any IP address within 192.168.40.2 to 192.168.40.251 is good to connect to the Outdoor NWAP. IP Subnet Mask: 255.255.255.0 40 2 Figure 3-5
- 13 -
Owners Manual of DA2131-V1 5. Click OK to complete the IP parameters setting. For OS of Microsoft Windows NT:
1. Click the Start button and select Settings, then click Control Panel. The Control Panel window will appear. 2. Move mouse and double-click the right button on Network icon. The Network window will appear. Click Protocol tab from the Network window. 3. 4. 5. 6. 7. 8. Check the installed list of Network Protocol window. If TCP/IP is not installed, click the Add button to install it; otherwise go to step 6. Select Protocol in the Network Component Type dialog box and click Add button. Select TCP/IP in Microsoft of Select Network Protocol dialog box then click OK button to install the TCP/IP protocol, it may need the Microsoft Windows CD to complete the installation. Close and go back to Network dialog box after the TCP/IP installation. Select TCP/IP and click the properties button on the Network dialog box. Select Specify an IP address and type in values as following example. IP Address: 192.168.40.2, or any IP address within 192.168.40.2 to 192.168.40.251 is good to connect to the Outdoor NWAP. IP Subnet Mask: 255.255.255.0 Click OK to complete the IP parameters setting. 3.2 Web Login Open a WEB browser, i.e. Microsoft Internet Explore 6.1 SP1 or above, then enter 192.168.40.252 on the URL to connect the DA2131-V1. 40.252 DA2131-V1 Figure 3-6 After a moment, a login window will appear. Enter the User Name and Password. Then click the OK button.
- 14 -
Owners Manual of DA2131-V1 40.252 40.252 Figure 3-7 Login Window Default User name: admin Default Password: admin If the above screen does not pop up, it may mean that your web-browser has been set to a proxy. Go to Tools menu>Internet Options>Connections>LAN Settings, in the screen that appears, cancel the Using Proxy checkbox, and click OK to finish it. After you enter the username and password, the main screen appears as Figure 3-8 Figure 3-8 Web UI Screenshot The next chapter will introduce the functions of the web UI.
- 15 -
Owners Manual of DA2131-V1 Chapter 4. Basic System Settings Setup Wizard This Setup Wizard page guides you to configure the Internet connection and Wireless Settings quickly. Figure 4-1 Setup Wizard Click Next button to next step for Internet connection settings. There are five options (DHCP, Static Mode, PPPOE, L2TP, PPTP) for Internet connection on WAN port. a. DHCP (Auto Config) If your ISP provides the DHCP service, please choose Dynamic IP type, and the NWAP will automatically obtain IP parameters from your ISP. You can see the page as follows Figure 4-2 Step 1. DHCP
- 16 -
Owners Manual of DA2131-V1 The page includes the following fields:
This option specifies the Host Name of the Router. Description Object Host Name b. Static IP Address If your ISP provides a static or fixed IP Address, Subnet Mask, Gateway and DNS setting, select Static Mode (fixed IP). The Static IP settings page will appear, shown as following. The page includes the following fields:
Figure 4-3 Step 1. Static Mode Object IP Address Subnet Mask Default Gateway Enter the IP address in dotted-decimal notation provided by your ISP. Description Enter the subnet Mask in dotted-decimal notation provided by your ISP, usually is 255.255.255.0
(Optional) Enter the gateway IP address in dotted-decimal notation provided by your ISP. Primary/Secondary DNS
(Optional) Enter one or two DNS addresses in dotted-decimal notation provided by your ISP.
- 17 -
c. PPPOE Connection If your ISP provides a PPPoE connection, select PPPoE option. And enter the following parameters. Owners Manual of DA2131-V1 Figure 4-4 Step 1. PPPOE The page includes the following fields:
Object User Name/Password Verify Password Operation Mode Description Enter the User Name and Password provided by your ISP. These fields are case-sensitive. Fill in the password again for verification.
Keep Alive: Keep the PPPoE connection all the time. Please also configure the Redial Period field.
On Demand: Please configure the Idle Time field. When time is up, the PPPoE connection will disconnect. The connection will re-
connect when any outgoing packet arise.
Manual: Let user connect the PPPoE connection manually. Sometimes the connection cannot be terminated although you specify a time to Idle Time, since some applications are visiting the Internet continually in the background.
- 18 -
Owners Manual of DA2131-V1 d. L2TP If your ISP provides L2TP connection, please select L2TP option. And enter the following parameters. Figure 4-5 Step 1. L2TP The page includes the following fields:
Object Description L2TP Server IP Address Allow user to make a tunnel with remote site directly to secure the data transmission among the connection. User can use embedded L2TP client supported by this router to make a VPN connection. User Name/Password Address Mode If you select the L2TP support on WAN interface, fill in the IP address for it. Enter the User Name and Password provided by your ISP. These fields are case-sensitive.
Static: To configure the IP address information by manually, please fill in the related setting at below.
Dynamic: The option allows the machine to get IP address information automatically from DHCP server on WAN side.
- 19 -
Owners Manual of DA2131-V1 Fill in the IP address for WAN interface. Fill in the subnet mask for WAN interface. Fill in the default gateway for WAN interface out going data packets.
Keep Alive: Keep the L2TP connection all the time. Please also configure the Redial Period field.
Manual: Let user connect the L2TP connection manually. IP Address Subnet Mask Default Gateway Operation Mode e. PPTP If your ISP provides PPTP connection, please select PPTP option. And enter the following parameters. Figure 4-6 Step1. PPTP
- 20 -
Owners Manual of DA2131-V1 The page includes the following fields:
Object PPTP Server IP Address Description Allow user to make a tunnel with remote site directly to secure the data transmission among the connection. User can use embedded PPTP client supported by this router to make a VPN connection. If you select the PPTP support on WAN interface, fill in the IP address for it. User Name/Password Enter the User Name and Password provided by your ISP. These fields are case-sensitive. Address Mode Static: To configure the IP address information by manually, please fill in the related setting at below. Dynamic: The option allows the machine to get IP address information automatically from DHCP server on WAN side. IP Address Fill in the IP address for WAN interface. Subnet Mask Fill in the subnet mask for WAN interface. Default Gateway Fill in the default gateway for WAN interface out going data packets. Operation Mode Keep Alive: Keep the PPTP connection all the time. Please also configure the Redial Period field. Manual: Let user connect the PPTP connection manually. When you finish these settings, then click Next button to jump at Step2.
- 21 -
Owners Manual of DA2131-V1 Step 2: configure Wireless Settings There are five options (Disable, OPENWEP, SHAREDWEP, WPA-PSK, WPA2-PSK) for Wireless security connection. Figure 4-7 Step 2. Configure Wireless Settings Description Object Network Mode This field determines the wireless mode which the NWAP works on. Frequency (Channel) Network Name (SSID) This field determines which operating frequency will be used. The default channel is set to AutoSelect, so the NWAP will choose the best channel automatically. It is not necessary to change the wireless channel unless you notice interference problems with another nearby access point. Enter a value of up to 32 characters. The same name of SSID
(Service Set Identification) must be assigned to all wireless devices in your network. The default SSID is set to be Legrand WiFi. This value is case-sensitive. For example, LEGRAND is NOT the same as Legrand. Channel Bandwidth Select the operating channel width 20 MHz or 20/40 MHz. Security Mode
Disable: No security required
OPENWEP / SHAREDWEP:
When you select WEP, please input 5, 13 (ASCII), 10 or 26
(HEX) characters for WEP Key.
WPA-PSK / WPA2-PSK: You can enter ASCII characters between 8 and 63 characters or 8 to 64 Hexadecimal characters. When you finish these settings, then click Apply button to save.
- 22 -
4.2 Operation Mode Owners Manual of DA2131-V1 Figure 4-8 Operation Mode Configurations a. Bridge:
The Bridge mode allows that all Ethernet and wireless interfaces are bridged into a single Bridge interface. b. Gateway:
The Gateway mode allows that the first Ethernet port is treated as WAN port and the Ethernet port and the wireless interface are bridged together and are treated as LAN ports. c. Wireless ISP:
The Wireless ISP mode allows that the wireless interface is treated as WAN port, and the Ethernet ports are LAN ports.
- 23 -
4.3 Internet Settings 4.3.1 WAN Owners Manual of DA2131-V1 Figure 4-9 WAN Settings Enter the IP address in dotted-decimal notation provided by your ISP. Description Enter the subnet Mask in dotted-decimal notation provided by your ISP, usually is 255.255.255.0
(Optional) Enter the gateway IP address in dotted-decimal notation provided by your ISP.
(Optional) Enter one or two DNS addresses in dotted-decimal notation provided by your ISP. This option specifies the Host Name of the Router. Description Take NIC MAC address of PC on LAN side as the MAC address of WAN interface. a. STATIC Object IP Address Subnet Mask Default Gateway Primary/Secondary DNS b. DHCP Object Host Name MAC Clone
- 24 -
Owners Manual of DA2131-V1 c. PPPoE Object User Name/Password Enter the User Name and Password provided by your ISP. These fields are case-sensitive. Description Verify Password Fill in the password again for verification. Keep Alive: Keep the PPPoE connection all the time. Please also configure the Redial Period field. On Demand: Please configure the Idle Time field. When time is up, the PPPoE connection will disconnect. The connection will re-connect when any outgoing packet arise. Manual: Let user connect the PPPoE connection manually. Description Operation Mode d. L2TP Object L2TP Server IP Address Allow user to make a tunnel with remote site directly to secure the data transmission among the connection. User can use embedded L2TP client supported by this router to make a VPN connection. User Name/Password Address Mode IP Address Subnet Mask Default Gateway Operation Mode e. PPTP Object PPTP Server IP Address If you select the L2TP support on WAN interface, fill in the IP address for it. Enter the User Name and Password provided by your ISP. These fields are case-sensitive.
Static: To configure the IP address information by manually, please fill in the related setting at below.
Dynamic: The option allows the machine to get IP address information automatically from DHCP server on WAN side. Fill in the IP address for WAN interface. Fill in the subnet mask for WAN interface. Fill in the default gateway for WAN interface out going data packets.
Keep Alive: Keep the L2TP connection all the time. Please also configure the Redial Period field.
Manual: Let user connect the L2TP connection manually. Description Allow user to make a tunnel with remote site directly to secure the data transmission among the connection. User can use embedded PPTP client supported by this router to make a VPN connection.
- 25 -
Owners Manual of DA2131-V1 If you select the PPTP support on WAN interface, fill in the IP address for it. Enter the User Name and Password provided by your ISP. These fields are case-sensitive.
Static: To configure the IP address information by manually, please fill in the related setting at below.
Dynamic: The option allows the machine to get IP address information automatically from DHCP server on WAN side. Fill in the IP address for WAN interface. Fill in the subnet mask for WAN interface. User Name/Password Address Mode IP Address Subnet Mask Default Gateway Fill in the default gateway for WAN interface out going data packets. Operation Mode 4.3.2 LAN
Keep Alive: Keep the PPTP connection all the time. Please also configure the Redial Period field.
Manual: Let user connect the PPTP connection manually. The page includes the following fields:
Figure 4-10 LAN Settings
- 26 -
Owners Manual of DA2131-V1 Object MAC Address IP Address Subnet Mask Description The physical address of the NWAP, as seen from the LAN. The value can't be changed. Enter the IP address of your NWAP or reset it in dotted-decimal notation
(factory default: 192.168.40.252). An address code that determines the size of the network. Normally use 255.255.255.0 as the subnet mask. Default Gateway Fill in the default gateway for LAN interfaces out going data packets. DHCP Type Start IP Address End IP Address
Disable: Disable DHCP server on LAN side. Server: Enable DHCP server on LAN side.
Fill in the start IP address to allocate a range of IP addresses; client with DHCP function set will be assigned an IP address from the range. Fill in the end IP address to allocate a range of IP addresses; client with DHCP function set will be assigned an IP address from the range. Lease Time Fill in the lease time of DHCP server function. 802.1d Spanning Tree Select enable or disable the IEEE 802.1d Spanning Tree function from pull-
down menu. LLTD Select enable or disable the Link Layer Topology Discover function from pull-down menu. IGMP Proxy Select enable or disable the IGMP proxy function from pull-down menu. UPNP DNS Proxy Select enable or disable the UPnP protocol from pull-down menu. Select enable or disable the DNS Proxy function from pull-down menu.
- 27 -
Owners Manual of DA2131-V1 4.3.3 DHCP Clients The DHCP clients page shows all the active DHCP clients. The table window shows the active clients with their Hostname, MAC address, assigned IP address, and time expired information. Figure 4-11 DHCP Clients 4.3.4 VPN Passthrough Figure 4-12 VPN Passthrough The page includes the following fields:
Object L2TP Passthrough IPSec Passthrough PPTP Passthrough Description Select enable or disable the L2TP pass-through function from pull-
down menu. Select enable or disable the IPSec pass-through function from pull-down menu. Select enable or disable the PPTP pass-through function from pull-down menu.
- 28 -
4.4 Wireless 4.4.1 Basic Owners Manual of DA2131-V1 Figure 4-13 Basic Wireless Settings The page includes the following fields:
Object Description Wireless On/Off Click Wireless OFF button to turn off wireless RF radio. Click Wireless ON button to turn on wireless RF radio. Antenna Switch Select Internal antenna or External antenna for using. The default is using Internal antenna. Wireless Mode Click to select wireless mode from pull down menu. SSID It is the wireless network name. The SSID can be 32 bytes long. User can use the default SSID or change it.
- 29 -
Broadcast Network Name (SSID) AP Isolation MBSSID AP Isolation Owners Manual of DA2131-V1 Enable or disable the SSID broadcast function. Wireless network is similar to the virtual local area network. All of the Wireless client devices can access each other completely. When you enable this function, it will turn off connection between wireless clients. Only allows connection between wireless client and this AP router. Enable this function will turn off connection between clients with different MBSSID. Example: The client connected with BSSID 1. When enable this function, it will not connect with BSSID 2. Only can access between clients with SSID 1. BSSID Show the MAC address of Wireless interface. Frequency (Channel) Select the wireless communication frequency/channel from pull-down menu. Operating Mode Select Mixed Mode for 11b/g/n mode or Green Field for 11n mode. Channel BandWidth Select the operating channel width 20 MHz or 20/40 MHz. Guard Interval Select Long or Auto. Guard intervals are used to ensure that distinct transmissions do not interfere with one another. Only effect under Mixed Mode. MCS Select 0~7 or Auto from pull down menu. The default is Auto. Only effect under Mixed Mode.
- 30 -
4.4.2 Advanced Owners Manual of DA2131-V1 Figure 4-14 Advanced Wireless Settings The page includes the following fields:
Object B/G Protection Mode Beacon Interval Description Default: Auto. You can select the other options including On and Off. The B/G protection technology is CTS-To-Self. It will try to reserve the throughput for 11g clients from 11b clients connecting to the device as AP mode. Beacons are the packets sending by Access point to synchronize the wireless network. The beacon interval is the time interval between beacons sending by this unit in AP or AP+WDS operation. The default and recommended beacon interval is 100 milliseconds. Data Beacon Rate(DTM) This is the Delivery Traffic Indication Map. It is used to alert the clients that multicast and broadcast packets buffered at the AP will be transmitted immediately after the transmission of this beacon frame. You can change the value from 1 to 255. The AP will check the
- 31 -
Owners Manual of DA2131-V1 buffered data according to this value. For example, selecting 1 means to check the buffered data at every beacon. The fragmentation threshold determines the size at which packets are fragmented (sent as several pieces instead of as one block). Use a low setting in areas where communication is poor or where there is a great deal of radio interference. This function will help you to improve the network performance. The RTS threshold determines the packet size at which the radio issues a request to send (RTS) before sending the packet. A low RTS Threshold setting can be useful in areas where many client devices are associating with the device, or in areas where the clients are far apart and can detect only the device and not each other. You can enter a setting ranging from 0 to 2347 bytes. The default TX power is 100%. In case of shortening the distance and the coverage of the wireless network, input a smaller value to reduce the radio transmission power. For example, input 80 to apply 80% Tx power. Default: Disable. It is a performance parameter for 802.11 b/g mode and not supported by some of very early stage of 802.11b station cards. If there is no such kind of stations associated to this AP, you can enable this function. It is used to shorten the communication time between this AP and station. The device will try to send a serial of packages with single ACK reply from the clients. Enable this function to apply it. Fragment Threshold RTS Threshold TX Power Short Preamble Short Slot TX Burst Country Code Select the country code for wireless from pull down menu.
- 32 -
Owners Manual of DA2131-V1 4.4.3 Security a. Disable Figure 4-15 Wireless Security Settings If you set Security Mode to Disable, the wireless data transmission will not include encryption to prevent from unauthorized access and monitoring.
- 33 -
b. OPEN-WEP Owners Manual of DA2131-V1 Figure 4-16 OPEN-WEP If you set Security Mode to OPEN-WEP or SHARED-WEP, please fill in the related configurations at below. Object Description Default Key WEP Keys
(1~4) Specify a Key number for effective. When you select the encryption type as WEP, please input 5, 13
(ASCII), 10 or 26 (HEX) characters for WEP Key.
- 34 -
c. SHARED-WEP Owners Manual of DA2131-V1 Figure 4-17 SHARED-WEP If you set Security Mode to OPEN-WEP or SHARED-WEP, please fill in the related configurations at below. Object Description Default Key WEP Keys
(1~4) Specify a Key number for effective. When you select the encryption type as WEP, please input 5, 13
(ASCII), 10 or 26 (HEX) characters for WEP Key.
- 35 -
d. WPA-RADIUS Owners Manual of DA2131-V1 Figure 4-18 WPA-RADIUS The page includes the following fields:
Object Description WPA Cipher Suite Select TKIP, AES or TKIPAES for WPA algorithms. Key Renewal Interval IP Address Port Shared Secret Session Timeout Idle Timeout Please fill in a number for Group Key Renewal interval time. Enter the RADIUS Servers IP Address provided by your ISP. Enter the RADIUS Servers port number provided by your ISP.
(The Default is 1812.) Enter the password that the Wireless Router shares with the RADIUS Server. Session timeout interval is for 802.1x re-authentication setting. Set to zero to disable 802.1x re-authentication service for each session. Session timeout interval unit is second and must be larger than 60. Enter the idle timeout in the column.
- 36 -
e. WPA-PSK Owners Manual of DA2131-V1 Figure 4-19 WPA-PSK The page includes the following fields:
Object Description WPA Cipher Suite Select TKIP, AES or TKIPAES for WPA algorithms. Pre-Shared Key Please fill in a passphrase like test wpa 123, or a hexadecimal string like '65E4 E123 456 E1'. Key Renewal Interval Please fill in a number for Group Key Renewal interval time.
- 37 -
f. WPA2-RADIUS Owners Manual of DA2131-V1 Figure 4-20 WPA2-RADIUS The page includes the following fields:
Object Description WPA Cipher Suite Select TKIP, AES or TKIPAES for WPA algorithms. Key Renewal Interval Please fill in a number for Group Key Renewal interval time. PMK Cache Period Only valid in WPA2 security. Set WPA2 PMKID cache timeout period, after time out, the cached key will be deleted. PMK Cache Period unit is minute. Pre-Authentication Only valid in WPA2 security. The most important features beyond WPA to become standardized through 802.11i/WPA2 are: Pre-authentication, which enables secure fast roaming without noticeable signal latency. Shared Secret Enter the password that the Wireless Router shares with the RADIUS Server.
- 38 -
Owners Manual of DA2131-V1 Session timeout interval is for 802.1x re-authentication setting. Set to zero to disable 802.1x re-authentication service for each session. Session timeout interval unit is second and must be larger than 60. Enter the RADIUS Servers IP Address provided by your ISP. Enter the RADIUS Servers port number provided by your ISP. (The Default is 1812.) Enter the password that the Wireless Router shares with the RADIUS Server. Session timeout interval is for 802.1x re-authentication setting. Set to zero to disable 802.1x re-authentication service for each session. Session timeout interval unit is second and must be larger than 60. Enter the idle timeout in the column. Session Timeout IP Address Port Shared Secret Session Timeout Idle Timeout g. WPA2-PSK Figure 4-21 WPA2-PSK The page includes the following fields:
Object Description WPA Cipher Suite Select TKIP, AES or TKIPAES for WPA algorithms. Pre-Shared Key Please fill in a passphrase like test wpa 123, or a hexadecimal string like '65E4 E123 456 E1'. Key Renewal Interval Please fill in a number for Group Key Renewal interval time.
- 39 -
h. 802.1X Owners Manual of DA2131-V1 Figure 4-22 802.1X The page includes the following fields:
Object WEP IP Address Port Description Enable or Disable WEP encryption. Enter the RADIUS Servers IP Address provided by your ISP. Enter the RADIUS Servers port number provided by your ISP. (The Default is 1812.) Shared Secret Enter the password that the Wireless Router shares with the RADIUS Server. Session Timeout Session timeout interval is for 802.1x re-authentication setting. Set to zero to disable 802.1x re-authentication service for each session. Session timeout interval unit is second and must be larger than 60. Idle Timeout Enter the idle timeout in the column.
- 40 -
e. Access Policy Owners Manual of DA2131-V1 Figure 4-23 Access Policy The page includes the following fields:
Object Policy Description Select the Disabled, Allow or Reject of drop down menu choose wireless access control mode. This is a security control function; only those clients registered in the access control list can link to this NWAP. Add a station MAC Fill in the MAC address of client to register this AP router access capability.
- 41 -
Owners Manual of DA2131-V1 5.4.4 WDS In the Basic Wireless Settings page, select the Wireless Mode to WDS to setup the WDS connection. a. WDS Mode WDS mode allows user to operate as a standard WDS that forwards traffic between WDS links (links that connect to other units in Repeater). The MAC addresses of WDS peers must be configured on the Wireless 11n Access Points/ Repeaters. Basically this mode is used when you have a 2.4GHz outdoor router with more than one WDS link to other AP/Repeaters. Note: In this mode wireless clients will not be able to connect to the 2.4GHz outdoor router directly. Step 1. In the Basic Wireless Settings, configure Wireless Mode to WDS. Figure 4-24 Wireless Mode - WDS
- 42 -
Step 2. Go to Wireless Settings-> WDS, fill in the MAC Address of the remote site. Owners Manual of DA2131-V1 Figure 4-25 WDS Configuration 1. To Setup the WDS Connection, the channel must be the same in both sites. You should fix the channel from AutoSelect to a static one. 2. You must fill in the MAC Address by each other. For example, enter the MAC Address of the remote site to the settings of local site; and enter the MAC Address of the local site to the settings of remote site. 3. The Encryption Type must be the same in both sites if available. c. AP+WDS (Repeater) Mode Repeater mode allows user to operate as a wireless repeater, extending the range for remote wireless clients and connecting them to an AP connected to the wired network. The MAC addresses of WDS peers must be configured on the Wireless 2.4G Access Point/Repeater.
- 43 -
Step 1. In the Basic Wireless Settings, configure Wireless Mode to AP+WDS. Owners Manual of DA2131-V1 Figure 4-26 Wireless Mode AP+WDS
- 44 -
Step 3. Go to Wireless Settings-> WDS, fill in the MAC Address of the remote site. Owners Manual of DA2131-V1 Figure 4-27 WDS Configuration 1. To Setup the WDS Connection, the channel must be the same in both sites. You should fix the channel from AutoSelect to a static one. 2. You must fill in the MAC Address by each other. For example, enter the MAC Address of the remote site to the settings of local site; and enter the MAC Address of the local site to the settings of remote site. 3. The Encryption Type must be the same in both sites if available.
- 45 -
Owners Manual of DA2131-V1 4.4.5 Site Survey This page is used to view or configure other APs near yours. To connect with other AP by site survey, you need to configure the DA2131-V1 as AP Client mode in the Basic Wireless Settings page as following. Step 1. Go to Wireless Settings-> Basic, select the Wireless Moe to AP Client, Figure 4-28 Basic Wireless Settings Step 2. Go to Wireless Settings->Site Survey to scan the AP. Select the AP that you choose to connect, and then click Next.
- 46 -
Owners Manual of DA2131-V1 Figure 4-29 Site Survey - 1 The page includes the following fields:
Object Description SSID BSSID RSSI Channel Encrypt It shows the SSID of AP. It shows BSSID of AP. It shows the signal strength of current AP. It show the current channel of AP occupied. It shows the encryption status. Wireless Mode It show the wireless mode of AP. Step 3. If the AP has encryption setting, it will pop out a window for you filling the encryption setting. Please fill up the code, in this case, the code was 1234567890, and click Apply to connect with the AP.
- 47 -
Owners Manual of DA2131-V1 Figure 4-30 Site Survey - 2
- 48 -
Step 4. After connected with AP, you can open Status page under Administrator to check link status. Owners Manual of DA2131-V1 Figure 4-31 AP Status
- 49 -
Owners Manual of DA2131-V1 4.4.6 WPS This section will guide you to add a new wireless device quickly to an existing network by WPS (Wi-Fi Protected Setup) function. Step 1. Choose menu WPS, you will see the next screen. Figure 4-32 WPS Setup The page includes the following fields:
Object Description Select Enable or Disable the Wi-Fi Protected Setup function. Then click Apply button to take effect function after change. WPS Step 2. To add a new device:
If the wireless adapter supports Wi-Fi Protected Setup (WPS), you can establish a wireless connection between wireless adapter and Router using either Push Button Configuration (PBC) method or PIN method. To build a successful connection by WPS, you should also do the corresponding configuration of the new device for WPS function meanwhile. I. By Push Button Configuration (PBC) If the wireless adapter supports Wi-Fi Protected Setup and the Push Button Configuration (PBC) method, you can add it to the network by PBC with the following two methods.
- 50 -
Step 1: Choose PBC, and click Apply. Owners Manual of DA2131-V1 Figure 4-33 WPS - PBC Step 2: Press and hold the WPS Button equipped on the adapter directly for 2 or 3 seconds. Or you can click the WPS button with the same function in the configuration utility of the adapter. 1) Step 1 & 2 should process within two minutes. 2) DA2131-V1 only supports PBC method. Step 3: Wait for a while until the connection established to complete the WPS configuration.
- 51 -
4.5 Firewall 4.5.1 MAC /IP /Port Filtering Owners Manual of DA2131-V1 Figure 4-37 MAC/IP/Port filtering The page includes the following fields:
Object Description MAC/IP/Port Filtering Select Enable or Disable the MAC/IP/Port Filtering function. Source MAC address Fill in the MAC address of source NIC, to restrict data transmission. Dest IP Address Fill in the IP address of destination, to restrict data transmission. Source IP Address Fill in the IP address of source, to restrict data transmission. Protocol Select the protocol that you want to restrict. There are four options:
None, TCP, UDP and ICMP. Dest Port Range Fill in the start-port and end-port number of destination, to restrict data transmission. Source Port Range Fill in the start-port and end-port number of source, to restrict data transmission.
- 52 -
Owners Manual of DA2131-V1 Action Comment Select Accept or Drop to specify the action of filtering policies. Make a comment for the filtering policy. Delete Selected Click Delete Selected button to delete all that you selected. Click Reset button to clear selected items. Reset 4.5.2 Port Forwarding Figure 4-38 Port Forwarding The page includes the following fields:
Object Port Forwarding IP Address Port Range Description Select Enable or Disable the Port Forwarding function. To forward data packets coming from WAN to a specific IP address that hosted in local network behind the NAT firewall, fill in the IP address. To forward data packets coming from WAN to a specific IP address
- 53 -
Owners Manual of DA2131-V1 that hosted in local network behind the NAT firewall, fill in the port range. Specify protocol, TCP&UDP, TCP or UDP. Make a comment for the port forwarding policy. Click Delete Selected button to delete all that you selected. Click Reset button to clear selected items. Select Enable or Disable the Virtual Server function. To forward data packets coming from WAN to a specific IP address that hosted in local network behind the NAT firewall, fill in the IP address. To forward data packets coming from WAN to a specific IP address that hosted in local network behind the NAT firewall, fill in the public port. To forward data packets coming from WAN to a specific IP address that hosted in local network behind the NAT firewall, fill in the private port. Specify protocol, TCP&UDP, TCP or UDP. Make a comment for the virtual server policy. Click Delete Selected button to delete all that you selected. Click Reset button to clear selected items. Protocol Comment Delete Selected Reset Virtual Server IP Address Public Port Private Port Protocol Comment Delete Selected Reset 4.5.3 DMZ Figure 4-39 DMZ The page includes the following fields:
Object DMZ Settings DMZ IP Address Description Enable or Disable the DMZ function. To support DMZ in your firewall design, fill in the IP address of DMZ host that can be access from the WAN interface.
- 54 -
4.5.4 System Security Owners Manual of DA2131-V1 Figure 5-40 System Security The page includes the following fields:
Object Description Remote management Select Deny or Allow for remote management function. Ping form WAN Filter Select Disable or Enable for Ping permit from WAN. SPI Firewall Select Disable or Enable for SPI firewall function.
- 55 -
4.5.5 Content Filtering Owners Manual of DA2131-V1 Figure 4-41 Content Filtering The page includes the following fields:
Object Description Keyword URL Delete Reset Fill in a word for Webs Host Filter policy. Fill in a URL string for URL filter. Then click Add button to save the URL filter policy or click Reset button to clear the field. Click Delete button to delete all that you selected. Click Reset button to clear selected items.
- 56 -
4.6 Administrator 4.6.1 Management Owners Manual of DA2131-V1 Figure 4-42 System Management The page includes the following fields:
- 57 -
Owners Manual of DA2131-V1 Description Fill in the user name for web management login control. Fill in the password for web management login control. It shows the current time. Select the time zone in your country from pull-down menu.. Fill in NTP server IP address. Fill in a number to decide the synchronization frequency with NTP server. Click the drop down menu to pick up the right DDNS provider you registered. Fill in the account of DDNS you registered. Fill in the password of DDNS you registered. Fill in the domain name that you registered. Object Username Password Current Time Time Zone NTP Server NTP synchronization Dynamic DNS Provider Account Password DDNS 4.6.2 Upload Firmware Figure 4-43Upload F/W The page includes the following fields:
Object Description Location Click the Browse button to select the new firmware image file on PC. And click the Apply button to upgrade firmware.
- 58 -
4.6.3 Settings Management Owners Manual of DA2131-V1 Figure 4-44 Setting Management The page includes the following fields:
Object Description Export Button Click Export button to export the current configuration to your PC. Settings file location Click Browse button to select the configuration file from your PC, then click Import button to update the configuration. Load Default Button Click the Load Default button to reset the configuration parameter to factory defaults.
- 59 -
Owners Manual of DA2131-V1 4.6.4 Status This page shows the current status and some basic settings of the device, includes system info, Internet Configurations and Local Network. Figure 4-45 Status
- 60 -
4.6.5 System Log This page is used to view the system logs. Owners Manual of DA2131-V1 Figure 4-46 System Log The page includes the following fields:
Object Description Click the Refresh button to refresh the log shown on the screen. Click the Clear button to clear the log display screen. Refresh Clear
- 61 -
Appendix A: Specifications DA2131-V1 150Mbps 802.11n Wireless Outdoor Access Point Product Owners Manual of DA2131-V1 Hardware Specification Standard support Chipset Memory Interface Antenna Enclosure PoE IEEE802.11b/g IEEE 802.11n IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX IEEE 802.3x Flow Control Ralink RT3050 16 Mbytes DDR SDRAM 4 Mbytes Flash Wireless IEEE802.11b/g/n LAN: 1 x 10/100Base-TX, Auto-MDI/MDIX WAN: 1 x 10/100Base-TX, Auto-MDI/MDIX Internal (Default): 12dBi directional antenna (Vertical-Pol)
Horizontal: 60 degree
Vertical: 30 degree External (Option): RP-SMA type Connector
Switchable by Software
For External Antenna Mode, attach antenna before power on IP55 waterproof case Passive PoE / 12V DC Reset Button on PoE Injector LAN RJ-45 Pin Assignment: PIN 4(+), PIN 7,8(-), PIN 5(Reset) Wireless Interface Specification Frequency Band Modulation Data Rate Opt. Channel RF Output Power Receiver Sensitivity 2.4~2.4835GHz Transmission/Emission Type: DSSS / OFDM Data modulation type: OFDM with BPSK, QPSK, 16-QAM, 64-QAM, DBPSK, DQPSK, CCK 802.11b: 11, 5.5, 2 and 1 Mbps with auto-rate fall back 802.11g: 54, 48, 36, 24, 18, 12, 9 and 6Mbps 802.11n (20MHz): up to 72Mbps 802.11n (40MHz): up to 150Mbp America/ FCC: 2.414~2.462GHz (11 Channels) Europe/ ETSI: 2.412~2.472GHz (13 Channels) Japan/ TELEC: 2.412~2.484GHz (14 Channels) 802.11b: 27 1dBm 802.11g: 26 1dBm 802.11n: 22 1dBm IEEE 802.11b: -93dBm IEEE 802.11g: -91dBm IEEE 802.11n: -812dBm CSMA/CA Range 1~100, default:100 12V DC, 1A (switching) Media Access Control Output Power Control Power Requirements Wireless Management Features Wireless Mode
AP
- 62 -
Owners Manual of DA2131-V1
Client
WDS PtP
WDS PtMP
WDS Repeater (AP+WDS)
Universal Repeater (AP+Client) 20MHz / 40MHz 64/128-bits WEP WPA, WPA-PSK WPA2, WPA2-PSK 802.1X Enable it to isolate each connected wireless clients, to let them cannot access mutually. Provide wireless LAN ACL (Access Control List) filtering Wireless MAC address filtering Support WPS (WIFI Protected Setup ) Enable/Disable SSID Broadcast A protection mechanism prevents collisions among 802.11b/g modes 25 4 Built-in DHCP server supporting static IP address distributing Support UPnP Support IGMP Proxy, DNS Proxy Support 802.1d STP - Spanning Tree Protocol
Static IP
DHCP (Dynamic IP)
PPPoE
PPTP
L2TP
PPTP
L2TP
IPSec
Bridge
Gateway
Ethernet Converter (WISP) NAT firewall with SPI (Stateful Packet Inspection) Built-in NAT server supporting Port Forwarding (Virtual Server), and DMZ Built-in firewall with Port/ IP address/ MAC/ URL filtering 60 Network Time Management Web UI, DHCP Client, Configuration Backup & Restore, Dynamic DNS System Log Temp.: -20~70c, Humidity: 10%~95% non-condensing Temp.: -30~80c, Humidity: 5%~95% non-condensing IP65 CE / FCC / RoHS
- 63 -
Channel Width Encryption Security Wireless Isolation Wireless Security B/G Protection Mode Max. Wireless Client Max. WDS AP Software LAN WAN Protocol VPN Passthrough Operating Mode Firewall Max. Wired Client NTP Management Diagnostic tool Environment & Certification Operation Temp. Storage Temp. IP Level Regulatory
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-09-24 | 2422 ~ 2452 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-09-24
|
||||
1 | Applicant's complete, legal business name |
Pass & Seymour, Inc. d/b/a Legrand
|
||||
1 | FCC Registration Number (FRN) |
0020276143
|
||||
1 | Physical Address |
301 Fulling Mill Road
|
||||
1 |
Middletown, Pennsylvania 17057
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
J******@eurofins.de
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
YV8
|
||||
1 | Equipment Product Code |
DA2131-V1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
F****** D******
|
||||
1 | Title |
Sr. Electrical Engineer
|
||||
1 | Telephone Number |
71754********
|
||||
1 | Fax Number |
71770********
|
||||
1 |
f******@legrand.us
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Worldwide Testing Services (Taiwan) Co., Ltd.
|
||||
1 | Name |
T**** C****
|
||||
1 | Physical Address |
6F., No. 58, Lane 188, Ruey Kuand Rd.
|
||||
1 |
Taipei, 114
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
+886-******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
j******@wts-lab.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Outdoor 802.11n Wireless Access Point | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Worldwide Testing Services (Taiwan) Co. Ltd.
|
||||
1 | Name |
C****** T********
|
||||
1 | Telephone Number |
88626******** Extension:
|
||||
1 | Fax Number |
88626********
|
||||
1 |
j******@wts-lab.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412 | 2462 | 0.03412 | ||||||||||||||||||||||||||||||||||||
1 | 2 | 15C | 2422 | 2452 | 0.02805 |