4. Close the battery door. Note: While charging, you can continue to use the mouse only if the USB receiver is also plugged into the computer. The cable is only a charging cable and cannot replace the wireless connection. Troubleshooting If your Wireless Mouse does not function properly, please review the following steps for troubleshooting. Insure that the USB mini-receiver is properly inserted into your computers USB port. Try another USB port. Keep the mouse within one meter (3 feet) of the receiver. Metallic surfaces will shorten transmission distances. Try re-connecting the mouse with the receiver. Please see the section Connecting the Mouse with the Receiver. If you find you are having problems (erratic or no movement) or if the low battery light blinks red, you will need to recharge the mouse. Please see the section How to recharge. Maintenance of your Mouse You may clean the surface of the Mouse with a soft damp cloth. Do not use any harsh or abrasive cleaners. Before using any chemical cleaners, please test the results on the bottom of the device. Rechargeable NimH Battery Warning This product contains secondary user replaceable/technician replaceable 1.5 volts NiMh batteries. Only equivalent 1.5V NiMh batteries shall be used as Do not use or charge product nearby fire, stove or Do not mistreat or misuse battery or it may cause fire or For optimum performance of the product change or recharge the battery on display of Low battery indicator. Do not use different power supply than provided with this product. replacement. heated place. chemical burn. LOTUS PT-61L007 Getting Started Guide Important Ergonomic Information Long periods of repetitive motions using an improperly set-up workspace, incorrect body position, and poor work habits may be associated with physical discomfort and injury to nerves, tendons, and muscles. If you feel pain, numbness, weakness, swelling, burning, cramping, or stiffness in these areas, see a qualified health professional. Installation of the Mouse The USB receiver fits into the bottom of the mouse for storage. Insert the 2 AAA batteries into the mouse Simply plug your receiver into an open USB port to begin using your mouse. Note: for convenience and portability the receiver stores in the bottom of your mouse when not in use. Connecting the Mouse with the Receiver 1. Press the button on top of the receiver. 2. Press the connect button on the bottom of the mouse. Low Battery Light The low battery indicator on top of your mouse will blink red to indicate that the mouse needs to be recharged. Recharge your mouse batteries by using the integrated recharge cable inside the bottom of the mouse. Expected battery life is 2 to 3 months depending on usage. To extend battery life place the receiver in the bottom of the mouse when not in use. This will automatically turn your mouse off. How to recharge the mouse The USB charging cable is integrated into the bottom of the mouse 1. Open the battery door on the bottom of the mouse 2. Ease out the USB charging cable. Warning: the cable remains attached to the mouse, do dot force. 3. Plug the charging cable into a USB port on your computer
(make sure computer is turned ON) International Standards and Safety INVISIBLE LASER RADIATION: DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS; CLASS 1M LASER PRODUCT. This optical device complies with International Standard IEC 60825-1: 2001-08, Class 1M Laser Product Invisible and also complies with 21 CFR 1040.10 and 1040.1, except for deviations pursuant to Laser Notice Nr. 50, dated July 26, 2001: Emission of 2 diverging beams (+/-4) of infrared user-invisible light Maximum power 2x300uW with 2 interleaved lasers (duty cycle 24%), wavelength range (min 844, max 865 nano-meters) Operating temperature between 0C (32F) to 40C (104 F). CAUTION: This optical device has no serviceable parts. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Guidelines for safe and efficient use. A Class 1M Laser Product is safe under reasonably foreseeable conditions of operation, but may be hazardous if the user employs optics within the beam. It is recommended to observe the following precautions:
1. Viewing the laser output with certain optical instruments
(for example, eye loupes, magnifiers and microscopes) within a distance of 100mm may pose an eye hazard. 2. Do not direct the infrared beam at anyone's eye. 3. In the absence of proper operation and if troubleshooting is unsuccessful, switch off the device and call Logitech technical support. 4. Do not attempt to disassemble your product unless it is for end-of-life disposal. 5. Do not expose your product to liquid, humidity, or moisture. 6. Do not operate your product when the temperatures is outside the specified operating range of 0C (32F) to 40C (104 F). In case of exposure to out-of-range temperature environment, switch off the device, and allow temperature to stabilize within the specified operating temperature range before operating.