09/23/2009 Ins-30012-US OEM plastic reader keypad Technical Support
.800.672.PAXT support@paxton-access.com Technical help is available: Monday - Friday from 2:00 AM - 5:00 PM (PST) Saturday from :00 AM - 5:00 AM (PST) Documentation on all Paxton Access products can be found on our web site - http://www.paxton-access.com/
Suitability Wet environments Mounted on metal surface Security sensitive doors Readers mounted together 12 inches between readers Fitting Exit button
(push to make) Grey
+2V DC White
0V
2V DC release current rating must be less than A.
* The diode current rating must be equal to or greater than the current in the release Black
9-5V DC
(fuse rating 1A) User cards are NOT supplied with this unit. Please supply your own user cards. Page
Please read the following notes before installing Electrical shock from voltages used in this system can cause injury or death. Prior to making any electrical connections, or performing maintenance and repair, ensure power is removed. Mains electrical connections should be made only by qualified personel in accordance with local regulation. Safety goggles should be worn while using power tools. Fitting the keypad Step 1: Carefully mark out the mounting holes for the keypad and the hole of the cable feed. Step 2: Drill the marked holes for the mounting points and the cable feed. When drilling the holes, ensure that you are aware of any hidden cables or pipes. Once the holes have been drilled, fit the supplied wall plugs and feed the cable through the cable feed hole before securing the reader to the wall using the screws supplied. Step 3: Fit the keypad to the mounting plate and secure using the screw provided. FCC Compliance This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions:
() this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Page 2 Setting The Master Code The first time the keypad is turned on the RED and GREEN LEDs flash alternately. This indicates a 6 digit Master Code must now be entered. The Master Code allows access to the Programming Menu. To set the Master Code, do the following:
Press
Enter 6 digit Master Code Press
The factory User Code is now set to 7890 Enter 6 digit Master Code Press
Press
to exit programming see see mode for programming options for adding proximity tokens The Master Code must not contain a User Code (for example 123456 as a Master Code and 2345 as a User Code would cause the door to open before the Master Code had been entered. NOTE Changing the entry code Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 8 Enter code 4-8 digits Press
re-enter code Press
1 2 3 Changing the door open time Enter 6 digit Master Code
= Normal
= Delete}
= Master Press
to exit programming mode Press and hold for 3 seconds 5 The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press Enter 2 digits from 01 to 60 (default door open time is 07 seconds
to exit programming mode Changing the lock type Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 1
{press
= Fail open
= Fail locked
Press
to exit programming mode
= default Page 3 Changing the keypad backlight Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 0
= On
= Off{press
Press
to exit programming mode
= default Setting multiple entry codes
(maximum = 120) Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 2
= On
= Off{press
Press
to exit programming mode When in Multi User Code mode the (star) key must be pressed after the code is entered for the door to release. Setting the keypad sounder Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 3
= Off
= On{press
Press
to exit programming mode Setting the exit button mode Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 7 1 2 3
= Normal
(press once to open door)
= Toggle
= Disabled
(press once to open, press again to close)
(exit button does not open the door) Press mode}
to exit programming
= default
= default
= default Page
Setting the keypad for additional security Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 4
= On
= Off{press
Press
to exit programming mode When enabled, the keypad will deactivate for 60 seconds if there are 20 consecutive incorrect numbers entered
= default Changing the Master code Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 6 Enter new 6 digit Master code Press
Re-enter new 6 digit Master code Press
Press
to exit programming mode Resetting the keypad
(EXCEPT the master code) Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds 9 Enter Master code Press and hold for 3 seconds 9 Press
Resetting the keypad
(INCLUDING the Master code) Remove power to the keypad Press and hold 2 Re-apply power, still holding 2 Press
Once completed, all settings except the Master code will be restored to their default setting to exit programming mode Hold for 3 seconds 2 once power is applied Once reset, the keypad will need a new Master code set, as per the programming section Creating a master token This will be required for the addition of other proximity tokens and also the proximity programming functions. The first token must be registered as a Master token. Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds*
Press 1 Press
Press 1 Press
Present proximity token to the keypad Press 4 Press
exits programming mode Page 5 Adding proximity tokens Up to 2000 proximity tokens can be added to the keypad. Each token is allocated to a memory slot on the keypad. A note will need to be made of the memory slot a token is allocated to, a handy table is included in these instructions for this purpose. To add a proximity token to the reader do the following:
Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press Enter memory slot number Re-enter memory slot number Press Present proximity token to the keypad Press 1 or 2 or 3 Press to exit programming mode Adding proximity plus PIN tokens For additional security, you may wish a user to enter a PIN (personal identification number) as well as present a proximity token, in order to open the door. To configure a token to require PIN entry as well, do the following:
Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Enter memory slot number Enter PIN Press Press Press Press Re-enter memory slot number Re-enter PIN Present proximity token to the keypad Press
or
or
Press to exit programming mode Barring proximity tokens If a proximity token has been lost, or you no longer wish the user to gain entry, the proximity token can easily be removed from the system. To remove a user token, do the following:
Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Enter memory slot number Press Re-enter memory slot number Press Press
Press to exit programming mode Page 6 Technical Help Here is the list of topics about this product that receive the most technical support inquiries. We list them here to help you speed up the installation and trouble shooting process. 1. I have connected the keypad correctly. Why doesnt it open when I enter my code?
Q- Check that there is power to the keypad by setting the keypad backlight to ON, and listening for keypad beeps. Q If not, check the power supply. Q- Check that the green light flashes when the correct code is entered. If not, the code has not been entered Q correctly, or may have been incorrectly programmed initially. Q- Check that the lock is capable of operating with a 2V DC power supply. Q- Check the connections. 2. When I enter my code, I hear a click and the unit resets. Why does the release not unlock?
QThis can be caused by incorrect wiring of the output wires or the diode. If a DC lock is used, check that a diode Qis connected across the lock so that the band is nearest the +V connection. This fault may blow a fuse in the Qpower supply - check for above before replacing the fuse. 3. The door is always unlocked. Why, and how do I get it to lock again?
QIf the green light on the keypad is on constantly, check the type of lock that is fitted. If it is a fail open type, Qit requires power to be applied to its terminals to keep it locked. A fail locked type (more common) requires power Qonly when it is to be kept open. Refer to the programming instructions to set the keypad for the correct lock type. QIf this is set correctly, check all wiring for shorts or bad connections. Check that a diode is fitted to the DC lock Qand is connected correctly. If not, the keypad may be damaged and will have to be replaced. Damaged relay Qcontacts are not covered by product warranty. QIf the green light on the keypad is flashing, switch off the power. Wait for 10 seconds and switch the power Qon again. If the door is locked and the green light is on constantly again, it is likely that the user code is set to Qoperate in toggle mode. If you do not want toggle codes, reset the keypad and enter new codes accordingly. QIf on re-applying power, the keypads green light is still flashing, and the door is still open, check the exit button Q(grey) wires. These could be connected to an exit button of the incorrect type, or shorted by faulty wiring, or the Qexit button operation could be set incorrectly. Rectify and re-test. Features Number of Users Code length PIN length Door open time Silent operation Can be used with fail OPEN locks Can be used with fail CLOSED locks Exit button input Backlight Electrical Voltage Current Switchable current Environment Operating temperature Waterproof Cable length Dimensions Specifications Min
digits
sec Min 9V DC Min Max 2,000 8 digits 60 sec Max
5V DC 30 mA
A Max
digits Yes Yes Yes Yes Yes
-20C (-F) 55C (3F) IP67 Width 2 3/ inch Height
/2 inch Outdoor Use 3 yards Depth
/ inch Page 7 Page 8