Module Integration Guide HF RFID Reader Module
#70152029 PH RADIO MODULE IQR3-FP FCC ID: IREIQR3FP IC ID: 7037A-IQR3FP CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 1 of 11 Released EDM checkout 2023-MRZ-31 Table of Contents ........................................................................................................................... 1 General Description .................................................................................................................................... 3 1.1 Module description ............................................................................................................................. 3 1.2 Module features ................................................................................................................................. 3 1.3 1.4 Qualified personnel ............................................................................................................................ 3 Environmental conditions ................................................................................................................... 3 1.5 Module components .......................................................................................................................... 4 Interfacing of module ......................................................................................................................... 5 1.6 1.7 Labeling ............................................................................................................................................. 5 1.8 Mounting module inside host ............................................................................................................. 5 1.8.1 PCB outline of module for host integration .................................................................................... 5 1.8.2 Position of host interface connector............................................................................................... 5 2 Electrical characteristics ............................................................................................................................. 6 2.1 Maximum Ratings .............................................................................................................................. 6 2.2 2.3 2.4 2.5 Pin definition ...................................................................................................................................... 6 Supply voltage ................................................................................................................................... 7 Data Interface .................................................................................................................................... 7 ESD sensitivity ................................................................................................................................... 7 3 Firmware characteristics ............................................................................................................................ 8 Description of air interface ................................................................................................................. 8 3.1 3.2 3.3 Indicator Elements ............................................................................................................................. 8 Available UART commands and parameters .................................................................................... 8 3.4 Special test modes needed for certification ....................................................................................... 8 4 FCC Regulatory Information ....................................................................................................................... 9 4.1 4.2 User Guide Requirements ................................................................................................................. 9 Labeling Requirements ...................................................................................................................... 9 4.3 Approved Antennas ........................................................................................................................... 9 IC Regulatory Information ........................................................................................................................ 10 5 5.1 5.2 User Guide Requirements ............................................................................................................... 10 Labeling Requirements .................................................................................................................... 10 5.3 Approved Antennas ......................................................................................................................... 10 6 Change history ......................................................................................................................................... 11 CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 2 of 11 Released EDM checkout 2023-MRZ-31 1 General Description 1.1 Module description The module operates in the 13.56MHz HF frequency range and is optimized for use in industrial applications involving high distances. The device reads and writes passive tags in line with ISO 15693. The module can be used in the United States and Canada. The module is compliant with the relevant transmission regulations. The user can add LEDs to monitor the status of the module. The module has a typical detection range of around 30cm. This range is determined by the tag used and can be adjusted by configuring the transmission power. Other range influencing factors include the transponder size, the setup and installation of the specific application and the surrounding materials, particularly metal. For the actual read and write distances under real conditions, the combination of module and tag must be tested in the desired application. The radio module can be interfaced to various industrial busses by host product. 1.2 Module features Integrated coil antenna (magnetic near field)
- Flexible HF read/write module with high distance detection range
- Multi-tag reading of up to 20 tags ensures increased productivity
- Provides simple interface for host products 1.3 Qualified personnel Only appropriately trained and qualified personnel may carry out mounting, installation, commissioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation. Prior to using the product make yourself familiar with it. Read the document carefully. 1.4 Environmental conditions Operating or storing the module outside the specified range may damage the module. Also this could lead to incorrect operation of desired module functionality. To reach full temperature range a potting will be needed for end product, which allows better cooling of electronic. Table 1 Environmental operating conditions Absolute maximum rating Operation temperature (with non-transmission periods) Operation temperature (Continuous transmission mode) Storage temperature Value
-25 ... +70C
-25 ... +55C
-40 ... +85C CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 3 of 11 Released EDM checkout 2023-MRZ-31 1.5 Module components The radio module consist of 2 assembled PCBs with the electronic components and integrated coil antenna. On the electronics PCB are multiple shields used to cover RF sensitive parts. The host system is connected via 2x8Pin connector. Additional LEDs may be connected to module for visualization of module state. Figure 1 stack up of radio module CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 4 of 11 Released EDM checkout 2023-MRZ-31 1.6 Interfacing of module The interfacing of module is made in host product, which provides the typical 24V supply to the module. Also the digital interface of RFID reader is interfaced via serial interface at CMOS Levels. The housing of module is designed to be able to contain the host product as well and a variable amount of external connectors. 1.7 Labeling Figure 2 labeling of module The labeling of the module is applied on the shielding of module. 1.8 Mounting module inside host 1.8.1 PCB outline of module for host integration A 3D model of module can be requested by module integrator under a non-disclosure agreement. 1.8.2 Position of host interface connector A 3D model of module containing position of interface connector can be requested by module integrator under a non-disclosure agreement. CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 5 of 11 Released EDM checkout 2023-MRZ-31 2 Electrical characteristics 2.1 Maximum Ratings Table 2 Electrical operating conditions maximum ratings Supply voltage All digital interfacing signals 2.2 Pin definition Value typical 24V DC, range of 8 33V DC (absolute maximum) 3.3V LVCMOS Figure 3 Pinning of module to host connection Table 3 Pinning of module to host connection Provide supply here 8 33V DC Direction Bidirectional GROUND Usage host Bidirectional GROUND To host Bidirectional GROUND Pin Usage radio module GROUND 1 Supply voltage into module To module 2 GROUND 3 5V supply output 4 GROUND 5 Reserved 6 GROUND 7 UART 8 GROUND 9 10 UART direction 11 GROUND 12 UART 13 GROUND 14 RESET input 15 GROUND 16 3V3 supply output Bidirectional GROUND To module Bidirectional GROUND To host Bidirectional GROUND To host Bidirectional GROUND To module Bidirectional GROUND To host max 100mA supply for host DO NOT CONNECT Serial data from host to module Low = RX/ High = TX is active Serial data from module to host Pull to low level, to reset module max 50mA supply for host Level 5V 3.3V LVCMOS 3.3V LVCMOS 3.3V LVCMOS 3.3V LVCMOS 3.3V CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 6 of 11 Released EDM checkout 2023-MRZ-31 2.3 Supply voltage Nominal power supply voltage is 24 VDC; voltage range is 8 ... 33 VDC (absolute maximum). Supply must be SELV (Safety Extra Low Voltage). The current consumption is <=700mA at nominal voltage 24 VDC. The average power consumption is <=5W. 2.4 Data Interface UART interface is used for module configuration and RFID data transfer. 2.5 ESD sensitivity The digital interfacing signals must be protected against electro static discharge on host side, if made available to end user. CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 7 of 11 Released EDM checkout 2023-MRZ-31 3 Firmware characteristics 3.1 Description of air interface For detailed information about the air interface protocol please refer to ISO15693-3 and ISO15693-2. 3.2 Indicator Elements The module has option to connect 4 LEDs. The basic indicators denote:
Green LED: Power on Blue LED: Transmission mode Yellow LED: Read/write operation successful Red LED: Error state 3.3 Available UART commands and parameters The full command and parameter set can be requested under a non-disclosure agreement. 3.4 Special test modes needed for certification For certification a firmware including test modes can be requested by test laboratory under a non-disclosure agreement. This firmware will not be available for end user. CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 8 of 11 Released EDM checkout 2023-MRZ-31 4 FCC Regulatory Information 4.1 User Guide Requirements FCC Information This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Notice To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. FCC Exposure Information This equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux rayonnements ISED tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Ce transmetteur ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne. Warning!
Malfunctions with pacemakers This device does not exceed the permissible limits for electromagnetic fields. Maintain a minimum distance of 30 cm between the device and your pacemaker. Inadequate distance from the transmitter antenna can result in inhibitions, reprogramming, or incorrect stimulation pulses. 4.2 Labeling Requirements Contains FCC ID: IREIQR3FP 4.3 Approved Antennas Only module internal antenna can be used. CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 9 of 11 Released EDM checkout 2023-MRZ-31 5 IC Regulatory Information 5.1 User Guide Requirements IC Information This device complies with Industry Canada license exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. IC Exposure Information This equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux rayonnements ISED tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Ce transmetteur ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne. Warning!
Malfunctions with pacemakers This device does not exceed the permissible limits for electromagnetic fields. Maintain a minimum distance of 30 cm between the device and your pacemaker. Inadequate distance from the transmitter antenna can result in inhibitions, reprogramming, or incorrect stimulation pulses. Dysfonctionnement du stimulateur cardiaque Cet appareil ne dpasse pas les limites admissibles pour les champs lectromagntiques. Maintenez une distance minimale de 30 cm entre l'appareil et votre stimulateur cardiaque. Si la distance la tte de metteur est trop courte, des impulsions d'inhibition, de reprogrammation ou de stimulation incorrecte peuvent se produire. 5.2 Labeling Requirements Contains IC: 7037A-IQR3FP 5.3 Approved Antennas Only module internal antenna can be used. CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 10 of 11 Released EDM checkout 2023-MRZ-31 6 Change history Version 14-4772 14-4772A Date 2023-01-03 2023-03-31 Author Martin Schmitt Martin Schmitt Remarks Initial released version Updated exposure Information CONFIDENTIAL acc. to ISO 16016 Only valid as long as released in EDM!
Module Integration Guide for #70152029 Mannheim template: FTM-0027B scale:
respons date: 2023-03-31 14-4772A DF.MSH sheet 11 of 11 Released EDM checkout 2023-MRZ-31