HP7 MAIN UNIT Antenna For Communication with L.O.R.A. at Dealership
-
-
Logs All Dealer Remote Interactions Allows for over the air settings and firmware updates INTERNAL STARTER/IMMOBILIZER RELAY Low Current Relay 5 Amp MAX ORANGE/BROWN20 Immobilizer N.O. (87) YELLOW/ORANGE14 Immobilizer Control Coil 1 (86) ORANGE13 Immobilizer N.C. (87a) ORANGE/WHITE2 Immobilizer COMMON (30) NOTE: If Using this Relay:
Connect Yellow/Orange to (+) Positive Ignition to Control the Immobilizer Coil Negative When Armed Coil 2 (85 Controlled Internally) PARKING LIGHTS OR FACTORY SECURITY TRIGGER RELAY Relay is selected automatically by connections made and the system color WHITE/BLACK18 Internal Relay N.O. (87) BROWN/WHITE19 Internal Relay N.C. (87a) WHITE17 Internal Relay COMMON (30) Secondary Internal Relay
-Parking Light (BLUE AND RED SYSTEMS) Use White 30 and White/Black 87.
-Factory Security Trigger (GREEN SYSTEMS) Send: White 30 and White/Black 87 Open: White 30 and Brown/White 87a Coils 1 and 2 85 and 86 Controlled Internally Based on System POWER-UP/SHOCK SENSOR ADJUSTMENT PROCEDURE Upon power-up, the HP7 unit examines all wires connected along with their status in order to identify vehicle and load the proper Firmware and/or CAN file. If not properly powered up, unit will malfunction. 1. Connect Entire Harness - Keep Security Unit Disconnected 2. Connect Security Unit to Harness 3. Close the Driver Door - Dock Light will Flash every 3 Seconds 4. Turn Ignition On 5. Open the Driver Door (2 HONK) IMPORTANT: Repeat Steps 3-5 If You Do Not Get 2 Honks 6. Press Arm on the Dealer Remote (within 6 seconds) (1 HONK) 7. Turn Ignition Off (2 HONKS) - SHOCK SENSOR ADJUSTMENT MODE -
8. LED Will Flash Current Sensitivity Setting Default Sensitivity = 8
(1 = Lowest Sensitivity, 15 = Highest Sensitivity) 9. Press Programming Button to Match Desired Setting
(1 HONK and Light will Flash Current Setting) 10. Close Doors to Test USER MODE Shock Sensor Sensitivity Setting 6 FAST HONKS = Soft Impact No Factory Security Violation but Full Systems will Pre-Warn. 1 SOLID HONK = Sufficient Impact - Security Violation Across All Systems 11. Turn Ignition On to Save Settings and Exit (3 HONKS) SHOCK SENSOR ADJUSTMENT MODE (Post Power-Up) To Access Shock Sensor Adjustment Mode Separate from the Power Up Process:
1. Turn Ignition On then Off 2. Press and Hold the Programming Button for 5 Seconds 3. Wait for Horn to Honk then Release Button 4. Continue From Step 8 Above UNIT MEMORY REPORT BACK Check List of Security Violations by Zone 1. Turn Ignition On then Off and wait 10 Seconds. 2. Press the Programming Button 10 Times 3. LED will Turn Solid for 1 Second (to Start) 4. LED reports zones: 1, 2, 3, and/or 5 5. LED flashes quickly for 1 Second (to End)
(ZONES: 1-Shock, 2-Green Wire, 3-Brown Wire and 5-Activation Chip) YELLOW7 Ignition for Module
(+) Positive INPUT
-CAN DATA Ignition is Covered
-Hardwired Ignition Requires 1 Amp Diode CAN DATA Check Technotes for Functions Covered GREEN/YELLOW6 CAN High DATA I/O GREEN/WHITE5 CAN Low DATA I/O Ground for Single Wire CAN Systems ex: Chevy DATA FUNCTIONS OR HARDWIRE OPTION Connect for hardwire installs and if CAN Function is Not Available GREY/RED3 Lock
(-) Negative OUTPUT Limited Current - 300mA MAX GREY/GREEN24 Unlock
(-) Negative OUTPUT Limited Current - 300mA MAX GREEN/RED8 Arm Input
(+/-) INPUT Keyless Lock Motor (Req. 1 Amp Diode) BLACK/ORANGE23 Disarm 1 Input
(+/-) INPUT Keyless Unlock 1st Unlock Motor
(Requires 1 Amp Diode) BROWN9 Hardwire Doors TRIGGER INPUT (Requires 10K Ohm Resistor to 12V) GREY/BLACK21 Trunk TRIGGER INPUT (Requires 10K Ohm Resistor to 12V) BROWN/BLACK22 Inhibit (hopefully disarm)
(-) Negative INPUT DOME LIGHT FADE LEARNING PROCEDURE Learn Only In USER Mode AND Also, Only If Dome Light Fade is Longer than 5 Seconds 1. Enter Programming Mode and Change the Dome Light Fade Setting - Step 11 to 3 Honks. 2. Insert Activation Chip to Enter User Mode 3. Open Driver Door. 4. Press Arm, Disarm, Arm, Disarm, Arm on Vehicles Factory Remote Until Docking Station Light Illuminates Solid. 5. Close Driver Door in order for the Dome Light to Fade out. 6. Once Vehicles Dome Light Fades out, the Docking Station Light starts flashing again, signifying fade time has been learned. IMPORTANT: With Only the Driver Door Open, Our Security System Must be Armed, Disarmed, Armed, Disarmed and Armed all within 6 Seconds, the Light on Docking Station Must then Illuminate Solid (the learning process has started), All Doors Must Then be Closed for Dome Light to Fade Out. At this point the Vehicles Factory Dome Light Fade Time has been Learned. ALL DOOR UNLOCK To Unlock All Doors from One Unlock Press on Factory Remote NOTE: Only for vehicles that require Double Pulse to Unlock (Step 9 at 3 Honks) OR has CAN connections controlling unlock. 1.Turn Ignition On 2. Press the Unlock Switch, Inside Driver Door, 3 Times
(1 Honk = On/2 Honks = Off) SILENT ARMING 1. Turn Ignition On then Off. 2. Press the Programming Button 3 Times
(1 Honk = Audible Arm/Disarm Tones /2 Honks = Silent) RESET ALL FACTORY DEFAULTS Deletes Current Dealer Remote Code, Setting Changes, Firmware and/or CAN File 1. Disarm Unit. 2. Press Program Button 5 Times within 6 Seconds 3. Switch Ignition On then Off 5 Times within 6 Seconds (3 HONKS) DOCKING STATION HP5 DOCKING STATION PRIMARY HARDWIRE CONNECTIONS Hardwire Connection Required BLACK16 Ground
(-) Negative INPUT RED4 12 Volt (+) Constant
(+) Positive INPUT BLACK/WHITE7 Horn
(-) Negative OUTPUT Limited Current - 300mA MAX GREY1 Negative Out When Armed (Corner pin)
(-) Negative OUTPUT Limited Current - 300mA MAX GREY15 Trunk Shunt Motor
(+/-) Positive or Negative INPUT FEATURE SELECTION CHART ENTERING PROGRAMMING MODE O P T I O N 1 2 3 4 5 6 7 8 9 10 11 12
-
-
-
-
-
WHEN DISARMED, TURN IGNITION ON PRESS AND RELEASE PROGRAMMING BUTTON 3 TIMES TURN IGNITION OFF THEN ON AGAIN PRESS BUTTON TO SCROLL THROUGH FEATURES THE LED WILL FLASH TO INDICATE WHICH FEATURE YOU SCROLLED TO THE HORN WILL HONK 1,2 OR 3 TIMES TO INDICATE FEATURE SELECTION FEATURE SELECTION Auto Lock with Ignition Auto Unlock with Ignition Lock with Passive Arming INDICATION 1 HONK 2 HONKS 3HONKS Auto Lock On Auto Unlock On Auto Lock Off Auto Unlock Off Lock No Lock Passive/Active Arming Passive Arm Do o r Ou tp u t Active Arm Arm/Disarm Chirp Duration 15 ms 30 ms 55 ms
(Chrysler) Dealer Disarm Trigger Length User Mode Starter Kill
(Green System) Lock/Unlock Duration Short Lock/Unlock Duration Tap 1 Sec Starter Kill On Single Unlock No Tap 2 Sec 3 Sec Starter Kill Off 3.5 Seconds Double Unlock 400 ms 600 ms 800 ms Dome Light Fade No Fade Trigger Type Horn Dome Light Learning 5 Sec Siren HP7 INSTALL MANUAL DRAFT 1 6/25/2018 VERSION 1 PAGE 1 OF 2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-
-
-
-
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the 1. 2. device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
Lappareil ne doit pas produire de brouillage;
Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den 1. 2. compromettre le fonctionnement. HP7 INSTALL MANUAL DRAFT 1 6/25/2018 VERSION 1 PAGE 2 OF 2