all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
PITm3.x User manual | Users Manual | 1.35 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Report | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | PITm3.x User manual | Users Manual | 1.35 MiB |
PITm3.2p Operatorterminals OperatingManual1003176EN04 Preface Thisdocumentistheoriginaldocument. AllrightstothisdocumentationarereservedbyPilzGmbH&Co.KG.Copiesmaybemade forinternalpurposes.Suggestionsandcommentsforimprovingthisdocumentationwillbe gratefullyreceived. Pilz,PIT,PMI,PNOZ,Primo,PSEN,PSS,PVIS,SafetyBUSp, SafetyEYE,SafetyNETp,thespiritofsafetyareregisteredandprotectedtrademarks ofPilzGmbH&Co.KGinsomecountries. SDmeansSecureDigital Content Section1 Section2 Section3 Section4 Introduction 1.1 1.1.1 1.2 Validityofdocumentation Retainingthedocumentation Definitionofsymbols Overview 2.1 2.2 2.3 Featuresoftheoperatingmodeselectorswitch Featuresoftransponderkey Controlelements Safety 3.1 3.2 3.2.1 3.2.2 3.2.3 Intendeduse Safetyregulations Useofqualifiedpersonnel Warrantyandliability Disposal 5 5 5 6 7 8 9 10 12 12 13 13 13 13 Interfaceforstatusinformation Timingdiagramsforoperatoractions Timingdiagramfordeviceerror Timingdiagramsforusererror:"Noauthorisation"
Timingdiagramsforusererror:"Buttonoperatedincorrectly"
Operatingmodeinterface Switchbehaviourafteratransponderkeyisremoved Controlprogramrequirements KeyIDinterface KeyIDnumberofthetransponderkey CommunicationmodefordownloadingtheKeyIDnumber 14 Functiondescription 16 4.1 18 4.1.1 20 4.1.2 21 4.1.3 23 4.1.4 25 4.2 25 4.2.1 27 4.2.2 28 4.3 28 4.3.1 30 4.3.2 30 4.3.2.1 Transmittercontrolledcommunicationmode 31 4.3.2.2 Handshakecontrolledcommunicationmode 4.3.3 32 4.3.3.1 EvaluationoftheKeyIDnumberwithtransmittercontrolledcommunication32 4.3.3.2 EvaluationoftheKeyIDnumberwithhandshakecontrolledcommunica 35 Evaluationbyacontrolsystem Section5 Section6 tion Installation 5.1 5.2 5.3 Generalinstallationguidelines Dimensions Mountingcutout Wiring 6.1 6.2 6.3 Terminalconfiguration Connectingtheunit Connectiontoacontrolsystem Section7 Operation OperatingManualPITm3.2p 1003176EN04 39 39 40 41 42 42 43 44 47 3 Content 7.1 7.2 7.3 7.4 7.5 7.6 7.6.1 7.6.2 7.6.3 SelectoperatingmodesOM1...BA4 Selectspecialmode(service) Monitoringofoperatingtime Switchoverdelayt1 Troubleshooting Diagnostics Statusinformationabouttheinterfaceforstatusinformation Statusinformationaboutbuttonbacklighting Statusinformationviaauthorisationdisplay Section8 Section9 Section10 Technicaldetails 8.1 Safetycharacteristicdata Supplementarydata 9.1 Radioapproval Orderreference Product 10.1 10.2 Accessories 48 49 50 50 51 52 52 52 53 54 56 57 57 58 58 58 OperatingManualPITm3.2p 1003176EN04 4 Introduction 1 1.1 Introduction Validityofdocumentation ThisdocumentationisvalidfortheproductPITm3.2p.Itisvaliduntilnewdocumentationis published. Thisoperatingmanualexplainsthefunctionandoperation,describestheinstallationand providesguidelinesonhowtoconnecttheproduct. 1.1.1 Retainingthedocumentation Thisdocumentationisintendedforinstructionandshouldberetainedforfuturereference. OperatingManualPITm3.2p 1003176EN04 5 Introduction 1.2 Definitionofsymbols Informationthatisparticularlyimportantisidentifiedasfollows:
DANGER!
Thiswarningmustbeheeded!Itwarnsofahazardoussituationthatposes animmediatethreatofseriousinjuryanddeathandindicatespreventive measuresthatcanbetaken. WARNING!
Thiswarningmustbeheeded!Itwarnsofahazardoussituationthatcould leadtoseriousinjuryanddeathandindicatespreventivemeasuresthatcan betaken. CAUTION!
Thisreferstoahazardthatcanleadtoalessseriousorminorinjuryplus materialdamage,andalsoprovidesinformationonpreventivemeasures thatcanbetaken. NOTICE Thisdescribesasituationinwhichtheproductordevicescouldbedam agedandalsoprovidesinformationonpreventivemeasuresthatcanbe taken.Italsohighlightsareaswithinthetextthatareofparticularimport ance. INFORMATION Thisgivesadviceonapplicationsandprovidesinformationonspecialfea tures. OperatingManualPITm3.2p 1003176EN04 6 Overview 2 Overview Theoperatingmodeselectorswitchmayonlybeoperatedinconjunctionwithatranspon derkey.5transponderkeysareavailable,eachwithdifferentauthorisations. Fig.:Operatingmodeselectorswitchinanapplication(principle) OperatingManualPITm3.2p 1003176EN04 7 Transponder key24 V DCEvaluation deviceSafety control system (e.g. PNOZ m1p) with "1oon" evaluationHigher-levelprocess control systemSOM1SOM2SOM3SOM4SOM5ServiceIn nIn n+1In n+2In n+3In n+4A1A2IDo0 ... IDo3,IDi0, IDi1SIo0 ... SIo36464 Overview 2.1 4pushbuttonsforswitchingtheoperatingmode Featuresoftheoperatingmodeselectorswitch Theproducthasthefollowingfeatures:
} Supplyvoltage24VDC
} Selectedoperatingmodeisdisplayedthroughpushbuttonbacklighting
4operatingmodesOM1...OM4 1specialmodeOM5(Service) 5monitoredsemiconductoroutputs(24V)inaccordancewithEN614961 1semiconductoroutputperoperatingmode Interfaceforstatusinformation,consistingof4signaloutputs(24V)
} Statusinformationisdividedintoinformationclasses:
Operatoractions Selecttransponderkey Removetransponderkey Selectoperatingmode
Messages(e.g.usererror,fault) Interface(KeyIDinterface)fordownloadingtheKeyIDnumberofthetransponderkey youareusing,consistingof 4semiconductoroutputs(24V) 2inputs
} ConfigurablecommunicationmodefordownloadingtheKeyIDnumber Transmittercontrolledcommunicationmode Handshakecontrolledcommunicationmode
} AuthorisationsofatransponderkeyaredisplayedviaLEDs OperatingManualPITm3.2p 1003176EN04 8 Overview 2.2 Featuresoftransponderkey AtransponderkeycontainsaKeyIDnumberandtheauthorisationstowhichyoucan switchwiththattransponderkey. Features:
} Replacesthemechanicalkey
} Differentauthorisations
} Authorisationsareidentifiedviaprinted"KeyMode". OperatingManualPITm3.2p 1003176EN04 9 Overview 2.3 Controlelements Fig.:Frontview Legend:
[1]
ButtonforOM1/OM5 ButtonforOM2 ButtonforOM3 ButtonforOM4 Buttontoselectanoperatingmode 1 2 3 4 AuthorisationdisplayLEDstodisplaytheauthorisationsfortherelevanttranspon derkey 1 2 3 4 5 Slotforinsertingthetransponderkey Transponderkey AuthorisationforOM1 AuthorisationforOM2 AuthorisationforOM3 AuthorisationforOM4 AuthorisationforOM5
[2]
[3]
[4]
OperatingManualPITm3.2p 1003176EN04 10
[1][2][3][4]Overview Fig.:Viewfromabove Legend:
[1]
DIPswitchforconfiguringtheswitchingbehaviourafterthetransponderkeyhas beenremoved OperatingManualPITm3.2p 1003176EN04 11 4 3 2 1OnOffSOM1SOM2SOM3SOM4SOM5IDo0IDo1IDo2IDo3IDi0IDi1Slo0Slo1Slo2Slo3A1A2[1]Safety 3 3.1 Safety Intendeduse Theoperatingmodeselectorswitchissuitableformachinesthatcanbeoperatedinmul tipleoperatingmodeswithdifferentprotectivemeasuresand/orworkprocedures.Itenables youtoswitchbetweendefinedoperatingmodes,suchas:
} Setupmode
} Manualmode
} Automaticmode
} Service Theoperatingmodeselectorswitchmeetsthefollowingsafetyrequirements:
Interlocktoprotectagainstunauthorisedswitching Contactwithatransponderkeyisrequiredinordertoswitchtoanoperatingmode.
} Accessauthorisationsarerestrictedtocertaingroups Atransponderkeywiththerelevantauthorisationisrequiredinordertoswitchtoacer tainoperatingmode.
} Preventsunintentionalswitching Theswitchtoadifferentoperatingmodeisonlyrecognisedoncethecorresponding
(selection)pushbuttonhasbeenoperatedforadefinedperiod("deliberateoperatorac tion").Multipleoperationof(selection)pushbuttonsisdetected.
} Safe"1fromn"circuitoftheoperatingmodeoutputs Theoperatingmodeselectorswitchonlyeverleadstooneoperatingmodeoutput"1"
signal. Dependingontheapplicationareaanditsrespectiveregulations,theoperatingmodese lectorswitchcanbeuseduptoSILCL2(ENIEC62061)anduptoPLd
(ENISO138491),iftheoperatingmodesareevaluatedbyasafetycontrolsystemwith safe"1oon"evaluation. Switchingmustnotinitiateahazardousmovement,norcanitcancelanexistingcontrol command. OperatingManualPITm3.2p 1003176EN04 12 Safety 3.2 3.2.1 3.2.2 3.2.3 Safetyregulations Useofqualifiedpersonnel Theproductsmayonlybeassembled,installed,programmed,commissioned,operated, maintainedanddecommissionedbycompetentpersons. Acompetentpersonissomeonewho,becauseoftheirtraining,experienceandcurrentpro fessionalactivity,hasthespecialistknowledgerequiredtotest,assessandoperatethe workequipment,devices,systems,plantandmachineryinaccordancewiththegeneral standardsandguidelinesforsafetytechnology. Itisthecompanysresponsibilityonlytoemploypersonnelwho:
} Arefamiliarwiththebasicregulationsconcerninghealthandsafety/accidentpreven tion
} Havereadandunderstoodtheinformationprovidedinthisdescriptionunder"Safety"
} Andhaveagoodknowledgeofthegenericandspecialiststandardsapplicabletothe specificapplication. Warrantyandliability Allclaimstowarrantyandliabilitywillberenderedinvalidif
} Theproductwasusedcontrarytothepurposeforwhichitisintended
} Damagecanbeattributedtonothavingfollowedtheguidelinesinthemanual
} Operatingpersonnelarenotsuitablyqualified
} Anytypeofmodificationhasbeenmade(e.g.exchangingcomponentsonthePCB boards,solderingworketc.). Disposal
Insafetyrelatedapplications,pleasecomplywiththemissiontimeTMinthesafetyre latedcharacteristicdata.
} Whendecommissioning,pleasecomplywithlocalregulationsregardingthedisposalof electronicdevices(e.g.ElectricalandElectronicEquipmentAct). OperatingManualPITm3.2p 1003176EN04 13 Functiondescription 4 Functiondescription Theoperatingmodeselectorswitchenablesyoutoswitchbetween5differentoperating modes(operatingmodesOM1...OM4andspecialoperatingmodeOM5(Service)). ForOM1...OM4,onebuttoneachisavailable.Forthespecialoperatingmode(Service), buttonOM1mustbeoperatedforacertainperiod(seeMonitoringofoperating time[
50]).Eachbuttonisassignedamonitoredsemiconductoroutput.Operatingthe buttonchangesthesemiconductoroutputfroma"0"signaltoa"1"signal.Theoperating modeselectorswitchguaranteesthatonlyoneofthesemiconductoroutputshasa"1"sig nalatanyonetime. Fig.:Blockdiagram Legend:
TransponderKey UserInterface Electronickeytoenableachangeofoperatingmode
} Buttontoselecttheoperatingmode
} Authorisationdisplay(LEDstodisplaytheauthorisationsfor therelevanttransponderkey) OperatingManualPITm3.2p 1003176EN04 14 RFIDReceiverPowerUser InterfaceA1A2SOM1SOM2IDo0IDo1IDo2IDo3SOM3SOM4SOM5SIo0SIo1SIo2SIo3IDi0IDi1InputsTerminals(Safe) Operating Modes InterfaceKey ID InterfaceStatus InformationInterfaceTransponder Key Functiondescription A1,A2 SOM1SOM5 IDo0IDo3and IDi0IDi1 SIo0SIo3 Supplyvoltage Operatingmodeinterface Interfacetodisplaytheoperatingmodethatiscurrentlyselected, consistingof5monitoredoutputs KeyIDinterface InterfacetodownloadtheKeyIDnumbertoacontrolsystem, consistingof4outputsand2inputs Interfaceforstatusinformation Interfacetosignalstatusinformation, consistingof4signaloutputs Theoperatingmodeselectorswitchisprotectedagainstunauthorisedoperation.Aswitch betweenoperatingmodesmustbeenabledviaatransponderkey. Authorisationsofatransponderkey Atotalof5transponderkeysareavailableforanoperatingmodeselectorswitch.Each transponderkeyprovidesauthorisationtoswitchupto5operatingmodes,includingspecial authorisations.Atransponderkeycanbeidentifiedviatheprintedkeymode. Assignmentofkeymodestoauthorisations Designation KeyMode01 KeyMode02 KeyMode03 KeyMode04 KeyService Markingontransponderkey Authorisationforoperatingmode 1 2 3 4 Service OM1 OM1+OM2 OM1+OM2+OM3 OM1+OM2+OM3+OM4 OM1+OM2+OM3+OM4+OM5(Service) OperatingManualPITm3.2p 1003176EN04 15 Functiondescription 4.1 Interfaceforstatusinformation Variousstatusinformationcanbesignalledviatheinterfaceforstatusinformation(see Blockdiagram[
Thestatusinformationissubdividedintothefollowinginformationclasses:
} Operatoractions 14]).Thestatusinformationcanbeevaluatedthroughacontrolsystem. Inserttransponderkey Removetransponderkey Selectoperatingmode
} Messages(e.g.usererror,fault) NOTICE Whentheoperatingmodeisselected(SIo3SIo0=3h,8h...Bh)and whenthereisadeviceerror(Dh)theinformationremainsindefinitely present.Allotherinformationstaysactiveforjust200ms.Afterthattimethe selectedoperatingmodeisagaindisplayed. Statusinformation Reserved Reserved Transponderkey5Inserted[1]
OM5selected Transponderkey1Inserted[1]
Transponderkey2Inserted[1]
Transponderkey3Inserted[1]
Transponderkey4Inserted[1]
OM1selected OM2selected OM3selected OM4selected Noauthorisation[2]
Deviceerror[3]
Pushbuttonoperatedincorrectly[4]
Transponderkeyremoved Informationclass Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Operatoraction Usererror Error Usererror Operatoraction SIo3
(MSB) SIo2 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 SIo1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 SIo0
(LSB) 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Value
(in Hex) 0h 1h 2h 3h 4h 5h 6h 7h 8h 9h Ah Bh Ch Dh Eh Fh OperatingManualPITm3.2p 1003176EN04 16 Functiondescription
[1]Whenapushbuttonisreleased,informationastowhichtransponderkeyisusedwillbe displayedfor200ms(seeStatusinformation2hand4h7h).Theselectedoperating modeisthendisplayed(seeStatusinformation3hand8hBh). 18]. PleaserefertotheTimingdiagramsforoperatoractions[
[2]Thefault"Noauthorisation"(Ch)isregisteredinthefollowingcases:
} Operatingmodeselectedwithouttransponderkey
} Operatingmodeselectedwithatransponderkeythatisnotauthorisedfortheselected operatingmode
} Transponderkeyisnotauthorisedfortheactiveoperatingmode
} Transponderkeyisnotinsertedintimebeforetheoperatingmodeisselected PleaserefertotheTimingdiagramsforusererror:"Noauthorisation"[
21].
[3]"Deviceerror"(Dh)issignalledintheeventofaninternaldeviceerrororwhenoneof theoperatingmodeoutputsSOM1...SOM5arestuckbecauseofexternalvoltage(stuck at1orstuckat0). Remedy:
} Rectifyerror,switchsupplyvoltageoffandthenonagain
} Changetheunit PleaserefertotheTimingdiagramfordeviceerror[
20].
[4]Thefault"Pushbuttonoperatedincorrectly"(Eh)isdisplayedinthefollowingcases:
} Multipleoperationofpushbuttons
} Pushbuttonoperatedfortoolong(timeoutforOM1toOM4=5sandtimeoutforOM5=
10s) Note:Ifakeyisoperatedfor<50msthiswillnotbeevaluated,sotherewillbenore action.
} Pushbuttonwasreleasedafterthetransponderkeywasremoved PleaserefertotheTimingdiagramsforusererror:"Buttonoperatedincorrectly"[
23]. OperatingManualPITm3.2p 1003176EN04 17 Functiondescription 4.1.1 Timingdiagramsforoperatoractions ThefollowingtimingdiagramshowshowstatusinformationisregisteredatoutputsSlo0... Slo3,basedonoperatoractions. Legend:
Messageisdisplayedconstantly Messageisdisplayedbriefly(200ms) Selectoperatingmode 1. Startposition:
OM1selected DIPswitchindefaultsetting 2. Operatoraction:Inserttransponderkey
(e.g.AuthorisationKeyMode02) 3. Operatoraction:Selectoperatingmode
(e.g.Pressbutton"2"forOM2) 4. Operatoraction:Removetransponderkey Fig.:Timingdiagramfor"Selectoperatingmode"withDIPswitchsetting[1](defaultsetting) OperatingManualPITm3.2p 1003176EN04 18 Functiondescription Removetransponderkey 1. Startposition:
a OM5isselectedandthetransponderkey"KeyService"isinserted or a OneoftheoperatingmodesOM1...OM4isselectedandatransponderkeywith therelevantauthorisationisinserted 2. Operatoraction:Removetransponderkey Fig.:Timingdiagramfor"Removetransponderkey"withDIPswitchsetting[1](defaultsetting) Fig.:Timingdiagramfor"Removetransponderkey"withDIPswitchsetting[2]
Fig.:Timingdiagramfor"Removetransponderkey"withDIPswitchsetting[3]
OperatingManualPITm3.2p 1003176EN04 19 Functiondescription 4.1.2 Timingdiagramfordeviceerror ThefollowingtimingdiagramshowshowstatusinformationisregisteredatoutputsSlo0... Slo3,basedonadeviceerror. Legend:
Messageisdisplayedconstantly Messageisdisplayedbriefly(200ms) Deviceerror Fig.:Timingdiagramintheeventofadeviceerror OperatingManualPITm3.2p 1003176EN04 20 Functiondescription 4.1.3 Timingdiagramsforusererror:"Noauthorisation"
ThefollowingtimingdiagramshowshowstatusinformationisregisteredatoutputsSlo0... Slo3,basedontheusererror"Noauthorisation". Legend:
Messageisdisplayedconstantly Messageisdisplayedbriefly(200ms) Operatingmodeselectedwithouttransponderkey Fig.:Timingdiagramfor"Operatingmodeselectedwithouttransponderkey"
Operatingmodeselectedwithatransponderkeythatisnotauthorisedfortheselec tedoperatingmode Fig.:Timingdiagramforoperatingmodeselectionwherethereisinsufficientauthorisationfortheop eratingmoderequiringselection OperatingManualPITm3.2p 1003176EN04 21 Functiondescription Operatingmodeselectedwithatransponderkeythatisnotauthorisedfortheactive operatingmode Fig.:Timingdiagramforoperatingmodeselectionwherethereisinsufficientauthorisationfortheact iveoperatingmode Transponderkeyisnotinsertedintimebeforetheoperatingmodeisselected Fig.:Timingdiagramforselectingtheoperatingmodebeforethetransponderkeyisinserted OperatingManualPITm3.2p 1003176EN04 22 SIo3:0Key Mode 01Pushbutton9hOM2 selectedCh9hOM2 selectedNo authorisation4hTransponder Key 1 insertedttSIo3:0Key Mode 02Pushbutton 2"8hOM1 selectedCh8hOM1 selected5hTransponder Key 2 insertedNo authorisation8hOM1 selectedtt Functiondescription 4.1.4 Timingdiagramsforusererror:"Buttonoperatedincorrectly"
ThefollowingtimingdiagramshowshowstatusinformationisregisteredatoutputsSlo0... Slo3,basedontheusererror"Buttonoperatedincorrectly"
Legend:
Messageisdisplayedconstantly Messageisdisplayedbriefly(200ms) Multipleoperationofpushbuttons Fig.:Timingdiagramfor"Multipleoperationofbuttons"
OperatingManualPITm3.2p 1003176EN04 23 Functiondescription Buttonoperatedfortoolong
"Buttonoperatedfortoolong"withauthorisations"KeyMode01""KeyMode04"
or
"Buttonoperatedfortoolong"withauthorisation"KeyService"
Fig.:Timingdiagramfor"Buttonoperatedfortoolong"
Pushbuttonwasreleasedafterthetransponderkeywasremoved Fig.:Timingdiagramforusererrorswhenreleasingthebutton OperatingManualPITm3.2p 1003176EN04 24 SIo3:08hOM1 selectedEh8hOM1 selectedPushbuttons 1" 4"Key Mode 045 sPushbutton misusePushbutton 1"Key Service10 s8hEh8hOM1 selectedOM1 selectedPushbutton misusettSIo3:0ttSIo3:0Pushbutton 2"8hOM1 selectedFh8hOM1 selectedKey ServiceTransponder Key removedttEhPushbutton misuse Functiondescription 4.2 Operatingmodeinterface TheoperatingmodeinterfaceconsistsofthemonitoredoutputsSOM1SOM5(seeBlock diagram[
buttons,whichcanbeusedtoselectanoperatingmodeiftheyhavetherelevantauthorisa tion(transponderkey):
14])."SOM"standsfor"SafeOperatingMode".Theoutputsareassignedto Pushbutton 1 2 3 4 Output SOM1 SOM5 SOM2 SOM3 SOM4 Operatingmode OM1 OM5 TheoperatingmodeOM1/OM5isselected basedontheoperatingtimeofbutton1(see Monitoringofoperatingtime[
50]) OM2 OM3 OM4 4.2.1 Switchbehaviourafteratransponderkeyisremoved Ifthetransponderkeyisremovedafterchangingtoadifferentoperatingmode,itispossible toconfigurethesubsequentswitchbehaviourofSOM1SOM5.ADIPswitchisavailable forthispurpose(seeControlelements[
10]). NOTICE Pleasenotethefollowing:
Theconfigurationmayonlybeperformedbyacompetentperson. Theconfigurationmustbeperformedwhenthesupplyvoltageis switchedoff. Theconfigurationisadoptedasthedeviceisstartedup,providedthe switchsettingisvalid.Ifnot,thedeviceswitchestoa"Deviceerror"
faultcondition. Duringoperation,theDIPswitchsettingismonitoredforanychange. Iftheswitchsettingischangedduringoperation,thedeviceswitches toa"Deviceerror"faultcondition. OperatingManualPITm3.2p 1003176EN04 25 Functiondescription ConfigurationoptionsviatheDIPswitch DIPswitchsetting
[1]:Defaultsetting Operatingmode currentlyselected Assignedoutput OM1 OM2 OM3 OM4 SOM1 SOM2 SOM3 SOM4
[2]
[3]
OM5 OM1 OM2 OM3 OM4 OM5 OM1 OM2 OM3 OM4 OM5 SOM5 SOM1 SOM2 SOM3 SOM4 SOM5 SOM1 SOM2 SOM3 SOM4 SOM5 Behaviourafterthetransponder keyisremoved
} Operatingmodecurrentlyse lectedismaintained
} Theassignedbuttonisbacklit.
} Theassignedoutputhasa"1"
signal
} SwitchtoOM1
} Button1isbacklit
} SOM1hasa"1"signal
} Operatingmodecurrentlyse lectedismaintained
} OM1OM4:Theassigned buttonisbacklit. OM5:All4buttonsflash.
} Theassignedoutputhasa"1"
signal
} SwitchtoOM1
} Button1isbacklit
} SOM1hasa"1"signal NOTICE MakeabsolutelysurethatonlytheDIPswitchsettingsdescribedaboveare assessedasvalid.WithallotherDIPswitchsettings,thedeviceswitchesto a"Deviceerror"faultcondition. OperatingManualPITm3.2p 1003176EN04 26 4 3 2 1OnOff4 3 2 1OnOff4 3 2 1OnOff Functiondescription 4.2.2 Controlprogramrequirements InordertoachieveSILCL2(ENIEC62061)/PLd(ENISO138491)inanapplication,the evaluationmustbecarriedoutbyasafetyrelatedfunctionblock.Thesafetyrelatedfunc tionblockmustmeetthefollowingrequirements:
} Thefunctionblockmustenablesafe"1oon"evaluationoftheoutputsignalsatSOM1...
SOM5. Iftwoormoreoperatingmodesarepresentatthesametime,thismustbedetectedas anerror. INFORMATION Thefunctionblockmustbridgethet1switchoverdelay(seeSwitchover delayt1[
IfaPNOZmulti(e.g.PNOZm1p)isusedasthesafetycontrolsystemin conjunctionwithan"operatingmodeselectorswitch"functionelement,then thisrequirementismetautomatically. 50]). OperatingManualPITm3.2p 1003176EN04 27 Functiondescription 4.3 4.3.1 KeyIDinterface TheKeyIDinterface(seeBlockdiagram[
toacontrolsystem. 14])isusedtodownloadtheKeyIDnumber KeyIDnumberofthetransponderkey TheKeyIDnumberisusedtoclearlyidentifythetransponderkeyandisunique.Itisprin tedonthetransponderkeystypelabelasa9digitdecimalfigure. NOTICE Pleasenote:
TheKeyIDnumberisnotprintedonthetransponderkeypackaging. Ifthetransponderkeyislost,itisimpossibletosupplyareplacement transponderkeywithanidenticalKeyIDnumber. TheKeyIDnumberconsistsoftwoparts:
} Bit27=24:KeyMode(015D)
} Bit23=00:Consecutivenumber(0999999999D) Fig.:StructureoftheKeyIDnumber OperatingManualPITm3.2p 1003176EN04 28 Bit27 ... Bit24Bit23 ... Bit16Bit07 ... Bit00Consecutive NumberKey Mode Bit27 Bit26 Bit25 Bit2401 0 0 0 1 1D02 0 0 1 0 2D03 0 0 1 1 3D04 0 1 0 0 4DService 1 1 0 1 13DBit15 ... Bit080 ... 15D0 ... 999999999D Functiondescription Examples:
OperatingManualPITm3.2p 1003176EN04 29 11010000 00000010 1100Consecutive number: 44D0000 0000Key Mode ServiceKey-ID-Number: 13000004400100000 00001111 1110Consecutive number: 510D0000 0001Key Mode 02Key-ID-Number: 020000510 Functiondescription 4.3.2 4.3.2.1 CommunicationmodefordownloadingtheKeyIDnumber TheuniqueKeyIDnumberfortherelevanttransponderkeyisdownloadedtothehigher levelprocesscontrolsystemusingadefinedprotocol,dependingontheconfiguredcom municationmode.ThecommunicationmodeisconfiguredontheKeyIDinterfaceofthe operatingmodeselectorswitch(jumpersavailable/notavailable). Theoperatingmodeselectorswitchdetectstheconfiguredcommunicationmodeateach poweron.Aslongasvoltageisappliedtotheoperatingmodeselectorswitch,thecon figuredcommunicationmodewillbeactivethechangeincommunicationmodedoesnot comeintoeffectuntilthesupplyvoltageisswitchedoffandthenonagain. Itspossibletochoosebetweenthefollowingcommunicationmodes:
} Transmittercontrolledcommunicationmode
} Handshakecontrolledcommunicationmode Transmittercontrolledcommunicationmode Withtransmittercontrolledcommunicationmode,thedownloadoftheKeyIDnumberis startedbytheoperatingmodeselectorswitch(=transmitter). Featuresofthiscommunicationmode:
} DownloadofKeyIDnumberstartsoncethetransponderkeyisconnected
} Constantbitrate(100ms)
} Downloadon2datalines
} Constantdownloadtime(typ.1.8s)
} Monitoreddatadownload
} Downloadisrepeatedbyreconnectingthetransponderkey NospecialcodingisrequiredontheKeyIDinterfaceinordertodownloadtheKeyIDnum berofatransponderkeytothecontrolsystemintransmittercontrolledcommunication mode.TheterminalsontheKeyIDinterfaceareusedasfollows:
Input/outputsrequiredonthecontrolsystem:4inputsand2outputs KeyIDinterface IDo0 IDo1 IDo2 IDo3 IDi0 IDi1 Briefdescriptionofapplic ation IDsync IDclock IDout0 IDout1 IDin0 IDin1 Codingviajumpers Noconfigurationrequired OperatingManualPITm3.2p 1003176EN04 30 Functiondescription 4.3.2.2 Handshakecontrolledcommunicationmode Withhandshakecontrolledcommunicationmode,thedownloadoftheKeyIDnumberis startedbythecontrolsystem(Request). Featuresofthiscommunicationmode:
} Downloadstartsviaarequesttothecontrolsystem,oncethetransponderkeyiscon nected
} Downloadisrepeatedbyarenewedrequesttothecontrolsystem
} Variablebitrate(min.2PLCcyclesperbit)
} Downloadon1dataline
} Min.downloadtime:28Bit*(20ms+2*PLCcycle)
IdentifierforIDendforfeasibilitycheck Input/outputsrequiredonthecontrolsystem:3inputsand1output TheKeyIDinterfacemustbecodedwithajumperbetweenIDo3andIDi1inordertodown loadtheKeyIDnumberofatransponderkeytothecontrolsysteminhandshakecontrolled communicationmode.TheterminalsontheKeyIDinterfaceareusedasfollows:
Codingviajumpers KeyIDinterface IDo0 IDo1 IDo2 IDo3 IDi0 IDi1 Briefdescriptionofapplic ation IDsync IDresponse IDdata Coding:OUT IDrequest Coding:IN Inhandshakecontrolledcommunicationmode,theoperatingmodeselectorswitchcanbe operatedinafunctionalvariant.InthiscasetheKeyIDnumberofthetransponderkeyis notdownloadedtothecontrolsystem.ThecontrolsystemisonlyusedtoevaluateIDo0on theKeyIDinterface.InthiscaseIDo0isusedasasignaloutput,enablingthecontrolsys temtorecognisewhetherthetransponderkeyisvalid/invalid.Withthisfunctionalvariant, only1inputisrequiredonthecontrolsystem.TheunusedterminalsontheKeyIDinterface
(IDo1,IDo2andIDi0)mayremainunwired("open"). OperatingManualPITm3.2p 1003176EN04 31 IDi1 Coding: INIDo3 Coding: OUT Functiondescription 4.3.3 4.3.3.1 Evaluationbyacontrolsystem EvaluationoftheKeyIDnumberwithtransmittercontrolledcommunication Fig.:Timingdiagramfortransmittercontrolledsignaldownload Legend:
Theadditionalterminaldesignations(IDsync,IDclock,IDout0etc.)areabbreviationsfor theterminalsignal'sapplication. IDo0 Controlline Thesignalisgeneratedbytheoperatingmodeselectorswitch.
"0"signal
"1"signal Notransponderkeyisconnectedorthetransponderkeythat isconnectedisinvalid. Avalidtransponderkeyiscreated.Theoperatingmodese lectorswitchsignalstothecontrolsystemwhenthedown loadstarts.Thesignalispresentfor100ms. IDo1 IDo2,IDo3 IDi0,IDi1 Testpulseline Thesignalisgeneratedbytheoperatingmodeselectorswitchandindic atesthevalidityofthedatabitsatIDo2andIDo3.
} T=100ms
} Dutycycle=50%
DatalinesfortransmittingtheKeyIDnumber TheoperatingmodeselectorswitchsendstheKeyIDnumbertothecon trolsystemviathesetwodatalines. IDo2:
IDo3 DatalineforreadingbacktheKeyIDnumber ThecontrolsystemsendsthepreviouslyreceivedKeyIDnumberbackto theoperatingmodeselectorswitchviathesetwodatalines. IDi0:
IDi1 ReceiveBit27Bit14 ReceiveBit13Bit00 SendBit27Bit14 SendBit13Bit00 OperatingManualPITm3.2p 1003176EN04 32 IDo0(IDsync)Bit 27Bit 25 Bit 16Bit 15Bit 14IDo2(IDout0)Bit 26[c][d]tenIDo1(IDclock)[b]max. 100 msBit 13Bit 11 Bit 02Bit 11Bit 00IDo3(IDout1)Bit 12Bit 27Bit 25 Bit 16Bit 15Bit 14IDi0(IDin0)Bit 26Bit 13Bit 11 Bit 02Bit 11Bit 00IDi1(IDin1)Bit 12T[a]min. 60 ms[f][e]Functiondescription Downloadprocedure
[a]
[b]
[c]
[d]
[e]
[f]
TheoperatingmodeselectorswitchsetsthesignalatIDo0(IDsync:control line)to"1"for100ms,therebysignallingtothecontrolsystemthattransmis sionhasstarted. ArisingedgeatIDo1(IDclock:testpulseline)indicatesthatthedataatdata linesIDo2andIDo3ispresentandvalidandcanbereadbythecontrolsys tem. BythetimethereisafallingedgeatIDo1(IDclock:testpulseline),thecontrol systemmusthavesentthepreviouslyreadbitbacktotheoperatingmodese lectorswitchviathedatalinesIDi0andIDi1. BeforetherisingedgeatIDo1(IDclock:testpulseline),theoperatingmode selectorswitchreadsthebitssentbacktoIDi0andIDi1bythecontrolsystem andchecksitforequivalence. Atleast60msafterthefallingedgeatIDo1(IDclock:testpulseline),thelast bitsentbackbythecontrolsystemmustbepresentatdatalinesIDi0and IDi1. Amaximumof100msafterthefallingedgeatIDo1(IDclock:testpulseline), thelastbitsentbackbythecontrolsystemmustbepresentatdatalinesIDi0 andIDi1inotherwords,bythispointatthelatest,datatransfermustbecom pletedandthedatalinesmusthavea"0"signal. INFORMATION IfthecontrolsystemdoesnotfeedbackthepreviouslyreadBitscorrectly, thedownloadisabortedandrestarted.The"IDsync"signalissetonce again.ThedownloadisrepeateduntiltheKeyIDnumberisdownloaded completely. ThedownloadoftheKeyIDnumbertypicallytakes1.8s. OperatingManualPITm3.2p 1003176EN04 33 Functiondescription FlowchartforevaluatingtheKeyIDinterface Fig.:EvaluationoftheKeyIDnumberviaacontrolsystem(principle) OperatingManualPITm3.2p 1003176EN04 34
<IDsync> = 1Start<IDsync> = 0No<IDclock> = 1Read <IDout0> AND <IDout1>Increment Bit CounterSet <IDin0> = <IDout0> Set <IDin1> = <IDout1> <IDclock> = 0NoBit Counter = 14EndNoClear Bit CounterLast Bit Timer >= 60msStart Last Bit TimerNo[b][c][d][e][a]See Fig. Timing Diagramm of sender controlled signal transfer<IDsync> = 1Store ID-NumberClear<IDin0> AND <IDin1> [f]NoNoYes Functiondescription 4.3.3.2 EvaluationoftheKeyIDnumberwithhandshakecontrolledcommunication Fig.:Timingdiagramforhandshakecontrolledsignaldownload Legend:
Theadditionalterminaldesignations(IDsync,IDresponse,IDdataandIDrequestetc.)are abbreviationsfortheterminalsignal'sapplication. IDo0 Controlline Thesignalisgeneratedbytheoperatingmodeselectorswitch.
"0"signal Notransponderkeyisconnectedorthetransponderkeythatiscon nectedisinvalid.ThecontrolsystemcannotrequesttheKeyID number. Avalidtransponderkeyisconnectedandthecontrolsystemcanre questtheKeyIDnumber.
"1"signal IDo1 IDo2 IDi0 ten tv th ta ThedatabitatIDo2isinvalidandmaynotbeevaluated. ThedatabitatIDo2isvalidandmaybeevaluated. Handshakeline(Response) Thesignalisgeneratedbytheoperatingmodeselectorswitchandindicates whetheradatabitatIDo2isvalid/invalid.
"0"signal
"1"signal DatalinefordownloadingtheKeyIDnumber TheKeyIDnumber(28Bit)isgeneratedbytheoperatingmodeselectorswitch. ThedownloadbeginswithMSB(Bit27Bit00). Handshakeline(Request) Thesignalisgeneratedbythecontrolsystem.
"0"signal
"1"signal NobitisrequestedatIDo2 AnewbitisrequestedatIDo2. IDsyncEnableTime(min.0ms) DataOutputValidTime(max.10ms) DataOutputHoldTime(min.0ms) DataOutputAccessTime(max.10ms) OperatingManualPITm3.2p 1003176EN04 35 IDo0(IDsync)Bit 27Bit 25 Bit 02Bit 01Bit 00IDo2(IDdata)Bit 26tV[b][c][d][f]thtenIDo1(IDresponse)IDi0(IDrequest)[e][a]tatIDend200 ms[g]Functiondescription tIDend EndofKeyIDNumberTransfer(200ms) AfterthelastfallingedgeatIDi0,theoperatingmodeselectorswitchstillhasa
"1"signalatoutputIDo1for200ms.Inthisway,theendoftheKeyIDnumber andthereforetheendofthedownload(EndofKeyIDNumberTransfer)isdis played.Thiscanbeusedforthefeasibilitycheck. Downloadprocedure
[a]
[b]
[c]
[d]
[e]
[f]
[g]
"1"signalatIDo0(controlline):
Avalidtransponderkeyispresentattheoperatingmodeselectorswitch.
"1"signalatIDi0(handshakeline):
ThecontrolsystemrequestsadatabitatdatalineIDo2an(=Request).
"1"signalatIDo1(handshakeline):
Theoperatingmodeselectorswitchconfirmsthevalidityofthedatabitatdata lineIDo2(=Response).
"0"signalatIDi0(handshakeline):
Thecontrolsystemconfirmsthatithasreadtherequesteddatabitwithouterror.
"0"signalatIDo1(handshakeline):
Theoperatingmodeselectorswitchisreadytoissueanewdatabitatdataline IDo2.
"0"signalatIDo0(controlline):
Thetransponderkeyhasbeenremoved. ThecontrolsystemmustrequestallthedatabitsofaKeyIDnumber(Bit27 Bit00).OnlythenisitpossibletostartdownloadinganewKeyIDnumber.The endofthedownloadisindicatedbythesignalextension(tIDend)atIDo1. OperatingManualPITm3.2p 1003176EN04 36 Functiondescription Statusdiagramforhandshakecontrolledsignaldownload Fig.:Statusdiagramforhandshakecontrolledsignaldownload OperatingManualPITm3.2p 1003176EN04 37 Functiondescription FlowchartforevaluatingtheKeyIDinterface Fig.:EvaluationoftheKeyIDnumberviaacontrolsystem(principle) OperatingManualPITm3.2p 1003176EN04 38
<IDsync> = 1AND<IDresponse> = 0Increment Bit CounterSet <IDrequest> = 0Read Bit <IDdata>Start TimerSet <IDrequest>= 1Set Bit Counter = 0Store ID Number<IDresponse> = 1No<IDresponse> = 0Time Control<tIDend> >= 200msNoBit Counter = 28Start[a][b][c][d][e]Last Bit ControlData Read and AcknowledgeBit RequestRequirementSee Fig. Timing diagram of handshake controlled signal transfer:See Fig. State diagram of handshake controlled signal transfer:<IDsync> = 0[g]NoYesNoNo[f]Installation 5 5.1 Installation Generalinstallationguidelines
} TheinstallationsitemustconformtotheprotectiontypeIP54.
} Ensurethattheoperatingmodeselectorswitchhassufficientventilation.
} Attachtheoperatingmodeselectorswitchusingthebracketsprovided.
} Makesurethatthegasketisseatedcorrectly. OperatingManualPITm3.2p 1003176EN04 39 Installation 5.2 Dimensions Frontview Viewfrombelow OperatingManualPITm3.2p 1003176EN04 40 985536.337.749.61370.46 Installation 5.3 Mountingcutout OperatingManualPITm3.2p 1003176EN04 41 84.250.8 Wiring 6 6.1 Wiring Terminalconfiguration INFORMATION Theconnectionterminalsarenotsuppliedwiththeunit. Fig.:Terminalconfiguration Legend SOM1..SOM5 Operatingmodeinterface:Monitoredsemiconductoroutputsfortheop IDo0IDo3 IDi0IDi1 SIo0SIo3 A1,A2 eratingmodesOM1OM5 KeyIDinterface:Semiconductoroutputsforsendingtheoutputsignals tothecontrolsystem Thefunctionoftheterminalsdependsonthecommunicationmodethat hasbeenconfigured. KeyIDinterface:Inputsforreceivingtheinputsignalsfromthecontrol system Thefunctionoftheterminalsdependsonthecommunicationmodethat hasbeenconfigured. InterfaceforstatusinformationEvaluationofstatusinformation Terminalsforconnectingthesupplyvoltage Functionalearth OperatingManualPITm3.2p 1003176EN04 42 SOM1 1SOM2 2SOM3 3SOM4 4SOM5 5IDo0 1IDo1 2IDo2 3IDo3 4IDi0 5IDi1 6SIo0 7SIo1 8SIo2 9SIo3 10A1 11A2 12Fuctional Earth+24 V DC0VX1X2 Wiring 6.2 Connectingtheunit Proceedasfollows:
1. Connectingthesupplyvoltage a Connectthesupplyvoltageto(A1,A2). Pleasenotethefollowing:
Thepowersupplymustmeettheregulationsforextralowvoltageswithprotective separation(SELV,PELV). Thecablesfortheunit'ssupplyvoltage(A1,A2)mustbefittedwitha4Afuse, characteristicB/C. 2. Connectingtheoperatingmodeinterface'ssemiconductoroutputs a Connecttheoperatingmodeinterface'ssemiconductoroutputstoacontrolsystem thatsupports"1ooN"evaluation. Youmustreadtheinformationconcerningintendeduse(seeIntended use[
12]). 3. Connectingtheinterface'sterminalsforstatusinformation a Connecttheterminals(SIo0...SIo3)toacontrolsystemthatsupportsevaluationof thestatusinformation. 4. ConfigurecommunicationmodefordownloadingtheKeyIDnumber a TodownloadtheKeyIDnumberinhandshakecontrolledcommunicationmode, connectterminalsIDo3andIDi1oftheKeyIDinterface. Noconfigurationisrequiredfortransmittercontrolledcommunicationmode. 5. ConnectingtheterminalsoftheKeyIDinterface a Dependingontheselectedcommunicationmode,connecttheterminalsoftheKey IDinterfacetoacontrolsystemthatsupportsthedownloadoftheKeyIDnumber. or a ConnectIDo0toacontrolsystem,ifallyouwishtodoinhandshakecontrolled communicationmodeisevaluatewhetherthetransponderkeyisvalid/invalid.In thiscaseyouwillonlyuseIDo0asasignaloutput.Theunusedterminalsonthe KeyIDinterface(IDo1,IDo2andIDi0)mayremainunwired("open"). OperatingManualPITm3.2p 1003176EN04 43 Wiring 6.3 Connectiontoacontrolsystem Dependingontheapplicationareaanditsrespectiveregulations,theoperatingmodese lectorswitchcanbeuseduptoSILCL2(ENIEC62061)anduptoPLd
(ENISO138491),iftheoperatingmodesareevaluatedbyasafetycontrolsystemwith safe"1oon"evaluation. Theexamplesbelowmeetthefollowingconditions:
} APNOZm1pisusedasasafetycontrolsystem.
} An"operatingmodeselectorswitch"functionelementisconfiguredinthePNOZmulti Configuratorforsafe"1oon"evaluation.
} TheKeyIDinterfaceandtheinterfaceforstatusinformationareevaluatedviaahigher levelprocesscontrolsystem.
} Thecablesfortheunit'ssupplyvoltage(A1,A2)containa4Afuse,characteristicB/C. OperatingManualPITm3.2p 1003176EN04 44 Wiring Connectionfortransmittercontrolledcommunicationmode Fig.:Connectionfortransmittercontrolledcommunicationmode(example) OperatingManualPITm3.2p 1003176EN04 45 Wiring Connectionforhandshakecontrolledcommunicationmode Fig.:Connectionforhandshakecontrolledcommunicationmode(example) OperatingManualPITm3.2p 1003176EN04 46 Operation 7 Operation Switchonbehaviour INFORMATION Aftertheoperatingmodeselectorswitchisswitchedon(PowerON)orafter voltageisreturned(reset),operatingmodeOM1isselectedautomatically. Thisalsoappliesifnotransponderkeyisconnected,oratransponderkeyis detectedbutisinvalid. BehaviourintheeventofanerrorinoperatingmodesOM1OM4 NOTICE Intheeventofanerror,theunitdoesnotchangeoperatingmode.Theact iveoperatingmode(OM1,OM2,OM3orOM4)isdisplayedviathebacklit buttonandtheassignedsemiconductoroutputhasa1signal. BehaviourintheeventofanerrorinspecialoperatingmodeOM5(Service) NOTICE Intheeventofanerror,theunitdoesnotchangeoperatingmode.Faulty operationisindicatedbythefactthatallbuttonsareeitheralllitorallout. Theassignedsemiconductoroutputhasa1signal. OperatingManualPITm3.2p 1003176EN04 47 Operation 7.1 SelectoperatingmodesOM1...BA4 Prerequisites
} Atransponderkeywiththerelevantauthorisationsmustbepresent.
} Theoperatingmodeselectorswitchmustrecognisethetransponderkeyasvalid.
} Thetransponderkeymustbepresentattheoperatingmodeselectorswitchforthe wholetimethebuttonisoperated.
} Severalbuttonsmaynotbeoperatedsimultaneouslywhenselectinganoperating mode. Procedure 1. Establishtheconnectionwiththetransponderkey a Insertthetransponderkeyintotheslot. Note:Thetransponderkeymustsupporttheoperatingmode/operatingmodesinto whichyouwishtoswitch.TheauthorisationdisplayLEDsprovideinformationabout theauthorisationsavailablewiththerelevanttransponderkey(seeControl elements[
10]). 2. Selectoperatingmode a Selecttherequiredoperatingmodebypressingtherelevantbutton. Pleasenotetherequiredoperatingtime(seeMonitoringofoperating time[
litonceitisreleased. 50]).Theoperatingmodehasbeenselectedcorrectlyifthebuttonisrear 3. Completeoperatingmodeselection a Completetheoperatingmodeselectionbyremovingthetransponderkey. Onceyouhaveremovedthetransponderkey,theoperatingmodeselectorswitch behavesinaccordancewiththeconfiguration(seeSwitchbehaviouraftera transponderkeyisremoved[
25]). INFORMATION YoucanswitchatwillbetweentheindividualoperatingmodesOM1,OM2, OM3andOM4i.e.itispossibletoswitchfromOM1toOM3orfromOM4to OM2,forexample. OperatingManualPITm3.2p 1003176EN04 48 Operation 7.2 Selectspecialmode(service) Prerequisites
} AtransponderkeymustbeavailablewithauthorisationforspecialoperatingmodeOM5
(Service).
} Theoperatingmodeselectorswitchmustrecognisethetransponderkeyasvalid.
} Thetransponderkeymustbepresentattheoperatingmodeselectorswitchforthe wholetimethebuttonisoperated.
} Severalbuttonsmaynotbeoperatedsimultaneouslywhenselectinganoperating mode. Procedure 1. Establishtheconnectionwiththetransponderkey a Insertthetransponderkey"KeyService"intotheslot. Note:AllauthorisationdisplayLEDsmustlight(seeControlelements[
10]). 2. SelectspecialmodeOM5(Service) a Pressbutton1(OM1). 50]).Theoperatingmodehasbeenselectedcorrectlyifallthebuttons Pleasenotetherequiredoperatingtime(seeMonitoringofoperating time[
flashwhenbutton1isreleased.Thebuttonsflashforaslongastheyareinspecial operatingmodeOM5(Service). 3. Completeoperatingmodeselection a Completetheoperatingmodeselectionbyremovingthetransponderkey. Onceyouhaveremovedthetransponderkey,theoperatingmodeselectorswitch behavesinaccordancewiththeconfiguration(seeSwitchbehaviouraftera transponderkeyisremoved[
25]). INFORMATION SpecialoperatingmodeOM5(Service)canbeselectedfromanyoftheop eratingmodes. OperatingManualPITm3.2p 1003176EN04 49 Operation 7.3 Monitoringofoperatingtime Achangeofoperatingmodesisonlydetectediftherelevantbuttonhasbeenoperatedfora definedtimeperiod. Button'soperatingtime Pushbut ton 1 2 3 4 1 Operatingmode OM1 OM2 OM3 OM4 OM5(Service) Output SOM1 SOM2 SOM3 SOM4 SOM5 Operatingtime
>50msand
<5s
>5sand
<10s 7.4 Switchoverdelayt1 Onceabuttonhasbeenreleased,theassignedoutputontheoperatingmodeinterface switchestoa"1"signalaftertheswitchoverdelayt1haselapsed(seeTechnical details[
atatimehasa"1"signalattheassignedoutput. 54]).Thisdefinedswitchoverdelayguaranteesthatonlyoneoperatingmode Fig.:Timebehaviourwhenswitchingoperatingmode OperatingManualPITm3.2p 1003176EN04 50 SOM1SOM2SOM3SOM4SOM5t1t1 Operation 7.5 Troubleshooting Ifanerroroccursontheoperatingmodeselectorswitch,thelastoperatingmodetobeset willberetained. Error Unabletoswitchthe operatingmode Possiblecause Multipleoperationofbut tons Operatingtimetoolongor tooshort Transponderkeyisnotde tected Novalidauthorisation Remedy Makesurethatonlyonebuttonis operated Makesurethattheperiodofopera tionisobserved. Makesurethatthetransponderkey isconnectedtotheoperatingmode selectorswitchorinsertedcorrectly. Makesurethatyouuseatranspon derkeythathastherequiredau thorisation OperatingManualPITm3.2p 1003176EN04 51 Operation 7.6 7.6.1 7.6.2 Diagnostics Theoperatingmodeselectorswitchhasvariousoptionsfordisplayingstatusinformation:
} Buttonbacklighting
} Authorisationdisplay(LEDs15) Interfaceforstatusinformation(SIo0SIo3) Statusinformationabouttheinterfaceforstatusinformation Variousstatusinformationcanbesignalledviatheinterfaceforstatusinformation(see Blockdiagram[
(seeInterfaceforstatusinformation[
14]).Thestatusinformationcanbeevaluatedthroughacontrolsystem 16]). Statusinformationaboutbuttonbacklighting Pushbuttons14(seeControlelements[
tonbacklightingisusedtoindicatewhichoperatingmodeisactiveinotherwords,which output(SOM1...SOM5)hasa"1"signal. 10])havepushbuttonbacklighting.Pushbut Evaluationofpushbuttonbacklighting Legend:
LEDon LEDflashes LEDoff LEDpushbut ton1 LEDpushbut ton2 LEDpushbut ton3 LEDpushbut ton4 Meaning
} Nosupplyvoltage
} OM5(Service)isactive
} SOM1hasa"1"signal
} OM1isactive
} SOM1hasa"1"signal
} OM2isactive
} SOM2hasa"1"signal
} OM3isactive
} SOM3hasa"1"signal
} OM4isactive
} SOM4hasa"1"signal OperatingManualPITm3.2p 1003176EN04 52 Operation 7.6.3 Statusinformationviaauthorisationdisplay Ifatransponderkeyisinsertedintheslotoftheoperatingmodeselectorswitch,itsauthor isationsaredisplayedviatheauthorisationdisplayLEDs(seeControlelements[
10]). EvaluationofLEDsignals Legend:
LEDon LEDoff LED AllLEDs Status Meaning
} Notransponderkeyconnectedor
} Authorisationnotrecognised,ornotrecognised fully AuthorisationavailableforOM1...OM5 LED"1"
NoauthorisationforOM1 AuthorisationavailableforOM1 LED"2"
NoauthorisationforOM2 AuthorisationavailableforOM2 LED"3"
NoauthorisationforOM3 AuthorisationavailableforOM3 LED"4"
NoauthorisationforOM4 AuthorisationavailableforOM4 LED"5"
NoauthorisationforOM5 AuthorisationavailableforOM5 OperatingManualPITm3.2p 1003176EN04 53 Technicaldetails 8 Technicaldetails General Approvals Sensor'smodeofoperation Transponderinterface Energysupplytotransponder Operatingfrequency Electricaldata Supplyvoltage CE,FCC,IC,TV,cULusListed Transponder passive(batteryfree) 125kHz Voltage Kind Voltagetolerance Outputofexternalpowersupply(DC) ResidualrippleDC Continuousduty Statusindicator Inputs Number Signallevelat"0"
Signallevelat"1"
Voltageatinputs Inputcurrentrange Galvanicisolation Semiconductoroutputs Overallperformanceext.loading,semiconductor Numberofpositiveswitchingsinglepolesemicon ductoroutputs Switchingcapability Voltage Current Signallevelat"1"
Residualcurrentat"0"
Shortcircuitproof Times Switchondelay afterUBisapplied Supplyinterruptionbeforedeenergisation Switchoverdelayt1 Operatingtimepushbutton1...4 Operatingtime,servicepushbutton Environmentaldata Climaticsuitability Ambienttemperature Temperaturerange 24,0V DC 15%/+10%
1,0W 20%
100%
LED 2 3+5VDC 1530VDC 24VDC 2,0mA No 3,5W 13 24V 20,0mA UB0,5VDC 0,4mA Yes 1,0s 20ms 50ms 50ms...5s 5s...10s DINIEC6006823 055C OperatingManualPITm3.2p 1003176EN04 54 Technicaldetails Environmentaldata Storagetemperature Temperaturerange Climaticsuitability Inaccordancewiththestandard Humidity EMC Vibration Inaccordancewiththestandard Frequency Amplitude Airgapcreepage Inaccordancewiththestandard Overvoltagecategory Pollutiondegree Ratedinsulationvoltage Ratedimpulsewithstandvoltage Protectiontype Mountingarea(e.g.controlcabinet) Housing Terminals Mechanicaldata Operatingdistances TypicaloperatingdistanceSo Max.cablelength Material Bottom Front 2570C EN60068278 95%r.h.at40C EN6094751 EN6006826 10,055,0Hz 0,35mm EN606641 II 2 60V 0,80kV IP64 IP20 IP20 5,0mm 1000m ST+10Zn ABS Conductorcrosssectionwithscrewterminals 1coreflexible Fixingscrewstorquesettings Torquesettingwithscrewterminals Connectiontype Conductorcrosssectionwithspringloadedterminals:
Flexiblewith/withoutcrimpconnector Springloadedterminals:Terminalpointsperconnec tion Strippinglength Dimensions Height Width Depth Weight 0,251,50mm,2816 0,30Nm 0,25Nm Springloadedterminal,plugin,screwterminal, plugin 0,202,50mm,2412AWG 1 9,0mm 55,0mm 98,0mm 43,0mm 160g Wherestandardsareundated,the201002latesteditionsshallapply. OperatingManualPITm3.2p 1003176EN04 55 Technicaldetails 8.1 Safetycharacteristicdata Operating mode ENISO 138491:
2008 PL PLd ENISO 138491:
2008 Category Cat.3 EN62061 SILCL EN62061 PFHD[1/h]
IEC61511 SIL IEC61511 PFD SILCL2 1,10E08 SIL2 5,28E04 ENISO 138491:
2008 TM[year]
20 Alltheunitsusedwithinasafetyfunctionmustbeconsideredwhencalculatingthesafety characteristicdata. INFORMATION Asafetyfunction'sSIL/PLvaluesarenotidenticaltotheSIL/PLvaluesof theunitsthatareusedandmaybedifferent.Werecommendthatyouuse thePAScalsoftwaretooltocalculatethesafetyfunction'sSIL/PLvalues. OperatingManualPITm3.2p 1003176EN04 56 Supplementarydata 9 9.1 Supplementarydata Radioapproval FCC/ICapproval OperatingManualPITm3.2p 1003176EN04 57 USA/Canada FCC ID: VT8- IC: 7482A- FCC/IC-Requirements: This product complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standards. Operation is subject to the following two conditions: 1) this product may not cause harmful interference, and 2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent produit est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes: (1) le produit ne doit pas produire de brouillage, et (2) l'utilisateur de le produit doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. PITM3PITM3 Orderreference 10 10.1 Orderreference Product Type PITm3.2p PITm3.2pmachinetoolspic togram 10.2 Accessories Features Operatingmodeselectorswitch Operatingmodeselectorswitch Orderno. 402230 402231 Terminals Type Springloadedterminals Angledscrewterminals Screwterminals Features 1set 1set 1set Transponderkey Type PITm3keymode1 PITm3keymode2 PITm3keymode3 PITm3keymode4 PITm3keyservice Features TransponderKeyMode01 TransponderKeyMode02 TransponderKeyMode03 TransponderKeyMode04 TransponderKeyService Orderno. 402302 402303 402305 Orderno. 402211 402212 402213 402214 402215 OperatingManualPITm3.2p 1003176EN04 58 Frontcover y n a m r e G n i d e t n i r P 1 1 4 1 0 2
, 4 0 N E 6 7 1 3 0 0 1 1 1 0 2
, G K
. o C
H b m G z l i P The Best of German EngineeringPartner of:SupportTechnical support is available from Pilz round the clock. AmericasBrazil+55 11 97569-2804Canada+1 888-315-PILZ (315-7459)Mexico+52 55 5572 1300USA (toll-free)+1 877-PILZUSA (745-9872)AsiaChina+86 21 60880878-216 Japan+81 45 471-2281South Korea+82 31 450 0680Australia+61 3 95446300EuropeAustria+43 1 7986263-0Belgium, Luxembourg+32 9 3217575France+33 3 88104000Germany+49 711 3409-444Ireland+353 21 4804983Italy+39 0362 1826711Scandinavia+45 74436332Spain+34 938497433Switzerland+41 62 88979-30The Netherlands+31 347 320477Turkey+90 216 5775552United Kingdom+44 1536 462203You can reach our international hotline on: +49 711 3409-444 support@pilz.comCMSE, InduraNET p, PAS4000, PAScal, PAScong, Pilz, PIT, PLID, PMCprimo, PMCprotego, PMCtendo, PMD, PMI, PNOZ, Primo, PSEN, PSS, PVIS, SafetyBUS p, SafetyEYE, SafetyNET p, the spirit of safety are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.Pilz develops environmentally-friendly products using ecological materials and energy-saving technologies. products and environmentally-friendly solutions.Pilz GmbH & Co. KG Felix-Wankel-Strae 2 73760 Ostldern, GermanyTel.: +49 711 3409-0 Fax:+49 711 3409-133 info@pilz.comwww.pilz.com100XXXX-DE-0X0-0-2-3-000, 2014-00 Printed in Germany Pilz GmbH & Co. KG, 2014
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-02-26 | 0.125 ~ 0.125 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2015-02-26
|
||||
1 | Applicant's complete, legal business name |
Pilz GmbH & Co. KG
|
||||
1 | FCC Registration Number (FRN) |
0017145996
|
||||
1 | Physical Address |
Felix-Wankel-Strasse 2
|
||||
1 |
Ostfildern, 73760
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
w******@cetecom.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
VT8
|
||||
1 | Equipment Product Code |
PITM3
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** K******
|
||||
1 | Telephone Number |
+4971********
|
||||
1 | Fax Number |
+4971********
|
||||
1 |
j******@pilz.de
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Operating mode selector | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CTC advanced GmbH (former CETECOM ICT Services )
|
||||
1 | Name |
G****** S******
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC