all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
PSW1-15W-BK UserMan-US | Users Manual | 791.92 KiB | July 25 2019 | |||
1 |
|
09 PSW1-15W-BK IntPho r1 | Internal Photos | 954.55 KiB | July 25 2019 | |||
1 |
|
08 PSW1-15W-BK ExtPho r1 | External Photos | 575.75 KiB | July 25 2019 | |||
1 |
|
06 PSW1-15W-BK LabelSmpl-US r1 | ID Label/Location Info | 685.25 KiB | July 25 2019 | |||
1 |
|
10 PSW1-15W-BK TSup | Test Setup Photos | 249.22 KiB | July 25 2019 | |||
1 | 11 PSW1-15W-BK OpDes | Operational Description | July 25 2019 | confidential | ||||
1 | 12 PSW1-15W-BK BlkDia | Block Diagram | July 25 2019 | confidential | ||||
1 | 13 PSW1-15W-BK Schem | Schematics | July 25 2019 | confidential | ||||
1 |
|
14 PSW1-15W-BK TestRpt DCD r1 | Test Report | 1.11 MiB | July 25 2019 | |||
1 |
|
18 PSW1-15W-BK RFExp r1 | RF Exposure Info | 225.92 KiB | July 25 2019 |
1 | PSW1-15W-BK UserMan-US | Users Manual | 791.92 KiB | July 25 2019 |
IMPEREA Wireless Charging Pad-
Single Station-15W-Black PSW1-15W-BK USEMANUAL If you have an electrical device, such as a pacemaker, consult a physician before using this product. Do not place magnetic Use the specified Do not use a voltage Mal<e sure the wall charger When not in use, unplug cards or similar items near this product. power source and voltage. converter
/tavel adapter. all the way into the electrical outlet. is inserted the wall charger. and flat surface Place the unit on a sturdy Keep the unit out of reach of childen. during charging. CHARGING YUR EVICE Mal<e sure your device is Qi-compatible. If the case is metal, If you are having issues charging, remove prior to charging. remove your case. of t h e c h a rg i n g ca b l e and the other end u g o n e e n d into the wall charger into the Charger and flatsuface, Pad. Place it on a sturdy such as desl< or table. device e Place the Qi-compatible propeplacement. onto the Charger on rightfo The LED light and turn Green when full charging. will dtgcvjg Pad. Refer to diagrams directly when charging CLE ANING If the Charger Pad needs cleaning, wipe it using a soft, dry cloth. Never use any abrasive Periodically, wipe off any accumulated cleaning agents. dust SPECIFICATIONS Wireless Charging Pad:
Input: 5V-12V=2A MAX Output: up to 15W Transmission Conversion Rate: 73%
Product Dimensions:
Distance:
'.:,Bmm 76 X 76 X 8.8mm CHARCING PACJ:
No Serach1ng or Sl1pp1ng HAGE MULTIPLE CJEVIES:
WorWIh All 01navic:s damage or damgeto this product. cnldto fire, to follow injury the sfetyinstructions oproperty IMPOTANT S AFETY INSTUCTIONS Failure personal Make sure to read the entire Do not use this unit for anything l<eep the unit away from heat source and direct Do not expose the unit to extremely Use the product Do not let the unit come in contact other than its intended sunlight. with a temperature in a location manual. use. with water or any other liquid. high or low temperatures. electical shocl<, of 32F (0C) -95F (35C). If the unit becomes wet, immediately unplug it from the power source. the unit USB cord or wall charger accumulate Do not handle Do not let the dust or other things Do not use the unit ithas been dropped Repairs to electrical or damaged in any way. should only be performed by a qualified risl<. may place the user at serious equipment repairs with wet hands. on the product electrician. Improper and the wall charger. e Charging time will depend on the Your device the charging type of device. display You may remove your device from the ChagerPad at any time during the charging will progress. process. C, When charging remove the device Charging Pad. from the is complete, with part 15 of the FCC Rules. Operation is subject to the following two conditions. any interference received, including interference that may cause undesired interference
(for USA) or change complies to this equipment. is not responsible may not cause harmful must accept FCC NOTICE sdevice
(1) This device
(2) This device operation. The manufacturer tions opeatethe equipment. This equipment has been tested pursuant to part 15 of the FCC Rules. interference against harmful radio frequency energy harmful occur in a particular reception, correct
--Reorient
--Increase
--Connect
--Consult oanexperienced This equipment complies equipment and operated should This transmitter or relocate the separation between the equipment into an outlet the dealer which can be determined must not be co-located the interference interference be installed to radio communications. installation. by turning If this equipment However, there the equipment does cause harmful by one or more of the following the receiving measures:
antenna. the equipment and receiver. different on a circuit technician for help. limits for anyadiootvinterference caused Such modifications could or change by unauthorized modifica authority void the user's to and found to comply These limits with the limits are designed to provide This equipment installation. and used in accordance in a residential and, if not installed for a Class B digital reasonable device, protection generates, uses and can radiate with the instructions, that interference may cause will not is no guarantee interference to radio or television off and on, the user is encouraged to try to from that to which the receiver is connected. with FCC radiation exposure 20cm between in conjunction with any other with minimum or operating set forth for an uncontrolled environment. distance the radiator or transmitter. and your body. antenna This
1 | 09 PSW1-15W-BK IntPho r1 | Internal Photos | 954.55 KiB | July 25 2019 |
- Page 1 of 4 -
Photo 1 (For model PSW1-15W-BK ) Report No.: MTi190513E066-1 Photo 2 Coil Antenna
- Page 2 of 4 -
Photo 3 Report No.: MTi190513E066-1 Photo 4
- Page 3 of 4 -
Photo 5 Report No.: MTi190513E066-1 Photo 6
- Page 4 of 4 -
Photo 7 Report No.: MTi190513E066-1 Photo 8
1 | 08 PSW1-15W-BK ExtPho r1 | External Photos | 575.75 KiB | July 25 2019 |
- Page 1 of 3 -
Photo 1 (For model PSW1-15W-BK ) Report No.: MTi190513E066-1 Photo 2
- Page 2 of 3 -
Photo 3 Report No.: MTi190513E066-1 Photo 4
- Page 3 of 3 -
Photo 5 Report No.: MTi190513E066-1 Photo 6
1 | 10 PSW1-15W-BK TSup | Test Setup Photos | 249.22 KiB | July 25 2019 |
Model: PSW1-15W-BK Radiated emission below 30MHz Radiated emission above 30MHz Conducted emission
1 | 14 PSW1-15W-BK TestRpt DCD r1 | Test Report | 1.11 MiB | July 25 2019 |
Test Report FCC ID: 2ATDP-PSW-15W-BK Date of issue: July 25, 2019 Report Number:
MTi190513E066 Sample Description:
IMPEREA Wireless Charging Pad - Single Station - 15 W -
Black Model(s):
PSW1-15W-BK Applicant:
Power MP Electronics Co., Ltd. Address:
Unit 04, 7/F, Bright Way Tower, No. 33 Mong KOK Road, Kowlong, HongKong Date of Test:
May 08, 2019 July 25, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 2 of 24 -
Report No.: MTi190513E066 Table of Contents 1 GENERAL INFORMATION ...................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ............................................................................................ 4 1.2 TEST MODE ............................................................................................................................................. 4 1.3 EUT TEST SETUP .................................................................................................................................... 5 1.4 ANCILLARY EQUIPMENT ........................................................................................................................... 5 1.5 MEASUREMENT UNCERTAINTY ................................................................................................................. 5 2 SUMMARY OF TEST RESULT ................................................................................................................ 6 2.1 OPERATION CHANNEL LIST ....................................................................................................................... 6 2.2 TEST CHANNEL ....................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS ........................................................................................... 7 3.1 TEST LABORATORY .................................................................................................................................. 7 3.2 ENVIRONMENTAL CONDITIONS .................................................................................................................. 7 3.3 MEASUREMENT UNCERTAINTY .................................................................................................................. 7 3.4 TEST SOFTWARE ..................................................................................................................................... 7 4 5 LIST OF TEST EQUIPMENT .................................................................................................................... 8 TEST RESULTS ....................................................................................................................................... 9 5.1 ANTENNA REQUIREMENT .......................................................................................................................... 9 5.1.1 Standard requirement .................................................................................................................. 9 5.1.2 EUT Antenna ................................................................................................................................ 9 5.2 CONDUCTED EMISSION .......................................................................................................................... 10 5.2.1 Limits .......................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................. 10 5.3 RADIATED EMISSION .............................................................................................................................. 15 5.3.1 Limits .......................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH .......................................................................................................................... 21 5.4.1 Test method ............................................................................................................................... 21 5.4.2 Test result ................................................................................................................................... 21 PHOTOGRAPHS OF THE TEST SETUP ....................................................................................................... 22 PHOTOGRAPHS OF THE EUT ...................................................................................................................... 24 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 3 of 24 -
Report No.: MTi190513E066 Test Result Certification Applicants name:
Power MP Electronics Co., Ltd. Address:
Unit 04, 7/F, Bright Way Tower, No. 33 Mong KOK Road, Kowlong, HongKong Manufacture's name:
Power MP(Changping) Electronics Co., Ltd. Address:
Second Industrial Zone, Changping Park, Eastern Industrial Park, Changping Town, Dongguan City, Guangdong Provice, China Product name:
IMPEREA Wireless Charging Pad - Single Station - 15 W - Black Trademark:
Infinite Peripherals Model name:
PSW1-15W-BK Standards:
FCC Part 15C Test Procedure:
ANSI C63.10-2013 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by:
Jone Lee Reviewed by:
July 25, 2019 Blue Zheng July 25, 2019 Approved by:
Smith Chen July 25, 2019 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 4 of 24 -
Report No.: MTi190513E066 1 GENERAL INFORMATION 1.1 Feature of equipment under test (EUT) Product name:
IMPEREA Wireless Charging Pad - Single Station - 15 W - Black Model name:
PSW1-15W-BK Operation frequency:
115205 kHz Modulation type:
Load modulation Antenna type:
Coil Antenna Power supply:
DC 5V/9V/12V from adapter Battery:
Adapter information:
Model difference:
N/A N/A N/A 1.2 Test mode To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Test mode Mode 1 Description Wireless charging Note1: The test modes were carried out for all operation modes. The final test mode of the EUT was the worst test mode for EMI, and its test data was showed. Note2: EUT is tested under full load and belongs to the worst mode. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 5 of 24 -
Report No.: MTi190513E066 1.3 EUT test setup See photographs of the test setup in the report for the actual setup and connections between EUT and support equipment. 1.4 Ancillary equipment Equipment Adapter Load Model HA832
/
S/N
/
/
Manufacturer ZIMI
/
1.5 Measurement Uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Conducted emission(150kHz~30MHz) 2.5 dB Radiated emission(30MHz~1GHz) Radiated emission (above 1GHz) Temperature Humidity 4.2 dB 4.3 dB 1 degree 5 %
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 6 of 24 -
Report No.: MTi190513E066 2 SUMMARY OF TEST RESULT Item FCC Part No. Description of Test Result 1 2 3 4 FCC PART 15.203 Antenna requirement FCC PART 15.207 Conducted emission FCC PART 15.209 Radiated emission FCC Part 15.215 20dB bandwidth Pass Pass Pass Pass 2.1 Operation channel list Channel List Channel Low Middle High 2.2 Test channel Channel Middle Frequency (kHz) 115 145 205 Frequency (kHz) 145 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 7 of 24 -
Report No.: MTi190513E066 3 TEST FACILITIES AND ACCREDITATIONS 3.1 Test laboratory Test Laboratory Shenzhen Microtest Co., Ltd Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.:
448573 3.2 Environmental conditions Temperature:
15C~35C Humidity 20%~75%
Atmospheric pressure 98kPa~101kPa 3.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) RF frequency RF power, conducted 1 x 10-7 1 dB Conducted emission(150kHz~30MHz) 2.5 dB Radiated emission(30MHz~1GHz) Radiated emission (above 1GHz) Temperature Humidity 3.4 Test software Software Name Manufacturer RF Test System Farad 4.2 dB 4.3 dB 1 degree 5 %
Model LZ-RF Version Lz_Rf 3A3 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 8 of 24 -
Report No.: MTi190513E066 4 LIST OF TEST EQUIPMENT Equipmen Equipment Manufactur t No. MTI-E001 Name Spectrum Analyzer er Model Serial No. Calibratio n date Due date Agilent E4407B MY41441082 2018/09/18 2019/09/17 MTI-E004 EMI Test Receiver MTI-E006 Broadband antenna Rohde&schw arz schwarabeck MTI-E007 Horn antenna schwarabeck ESPI 1000314 2018/09/18 2019/09/17 VULB916 3 BBHA912 0D 872 2018/09/18 2019/09/17 1201 2018/09/18 2019/09/17 MTI-E014 amplifier America 8447D 3113A06150 2018/09/18 2019/09/17 MTI-E015 Immunity Signal Schloder CDG6000 Conduction 126A1343/20 15 2018/09/18 2019/09/17 MTI-E016 Generator Coupled decoupling network Schloder CND M2/M3 A2210332/20 15 2018/09/18 2019/09/17 MTI-E034 amplifier Agilent 8449B 3008A02400 2018/09/18 2019/09/17 MTI-E037 MTI-E040 Artificial power network Spectrum analyzer Schwarzbeck NSLK812 7
#841 2018/09/18 2019/09/17 Agilent N9020A MY49100060 2018/09/18 2019/09/17 MTI-E041 Signal generator Agilent N5182A MY49060455 2018/09/18 2019/09/17 MTI-E042 Analog signal generator MTI-E043 Power probe Agilent E4421B GB40051240 2018/09/18 2019/09/17 Dare RPR3006 16I00054SN Instruments W O16 2018/09/18 2019/09/17 MTI-E047 10dB attenuator Mini-Circuits UNAT-10+
15542 2018/09/18 2019/09/17 MTI-E049 MTI-E050 spectrum analyzer PSG Signal generator Active Loop Rohde&schw arz FSP-38 100019 2018/09/18 2019/09/17 Agilent E8257D MY46520873 2018/09/18 2019/09/17 MTI-E061 Antenna 9kHz -
Schwarzbeek MTI-E052 30MHz 18-40GHz amplifier Chengdu step Micro Technology MTI-E053 15-40G Antenna Schwarzbeek MTI-E058 Artificial power network Schwarzbeck FMZB 1519 B ZLNA-18-
40G-21 00044 2018/09/18 2019/09/17 1608001 2018/09/18 2019/09/17 BBHA917 BBHA91705 82 0 NSLK812 7 2018/09/18 2019/09/17
#841 2018/09/18 2019/09/17 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 9 of 24 -
Report No.: MTi190513E066 5 TEST RESULTS 5.1 Antenna requirement 5.1.1 Standard requirement 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device 5.1.2 EUT Antenna The EUT antenna is Coil Antenna. It comply with the standard requirement. In case of replacement of broken antenna the same antenna type must be used. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 10 of 24 -
Report No.: MTi190513E066 5.2 Conducted emission 5.2.1 Limits For the following equipment, when designed to be connected to the public utility (AC) power line the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies shall not exceed the limits in the following tables. Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal using a 50 H/50 ohms line impedance stabilization network
(LISN). Frequency
(MHz) 0.15 -0.5 0.5 -5 5 -30 Conducted limit (dBV) Quasi-peak 66 - 56 *
56 60 Average 56 - 46 *
46 50 Note : the limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 5.2.2 Test Procedures The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipment powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. LISN is at least 80 cm from nearest part of EUT chassis. For the actual test configuration, please refer to the related Item photographs of the test setup. 5.2.3 Test Setup 5.2.4 Test Result Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 11 of 24 -
Report No.: MTi190513E066 Temperature:
25.1 Relative Humidity:
68%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 120V/60Hz Phase:
L Test mode:
Mode 1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 12 of 24 -
Report No.: MTi190513E066 Temperature:
25.1 Relative Humidity:
68%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 120V/60Hz Phase:
N Test mode:
Mode 1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 13 of 24 -
Report No.: MTi190513E066 Temperature:
25.1 Relative Humidity:
68%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 240V/60Hz Phase:
L Test mode:
Mode 1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 14 of 24 -
Report No.: MTi190513E066 Temperature:
25.1 Relative Humidity:
68%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 240V/60Hz Phase:
N Test mode:
Mode 1 NoteThe 5V, 9V and 12V operating voltages have been tested and the results show that the 12V operating voltage data is the worst, and the report only shows the worst mode. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 15 of 24 -
Report No.: MTi190513E066 Field Measurement Field strength strength distance 5.3 Radiated emission 5.3.1 Limits Frequency Field strength
(MHz)
(V/m)
(dBV/m)*
0.009-0.49 2400/F(kHz) 48.5-13.8 0.49-1.705 24000/F(kHz) 33.8-23 1.705-30 30-88 88-216 216-960 960-1000 30 100 150 200 500 500 5000 29.5 40 43.5 46 54 54 74
(m)**
300 30 30 3 3 3 3 3 3
(dBV/m)
@3m**
128.5-93.8 73.8-63 69.5 40 43.5 46 54 54 74 Detector QP***
QP QP QP QP QP QP AV PK above 1000 above 1000
*: dBV/m = 20*log(V/m)
**: Limit 3m (dBV/m) = limit(distance) + 40*log(distance/3m) (blew 30MHz)
***: in 9-90kHz, 110-490KHz bands employing an AV detector FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators) Highest frequency generated or Upper frequency of measurement used in the device or on which the device operates or tunes (MHz) Below 1.705 1.705 108 108 500 500 1000 Above 1000 Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (emission in restricted band) Range (MHz) 30 1000 2000 5000 5th harmonic of the highest frequency or 40 GHz, whichever is lower Setting Auto 1000 MHz 10th carrier harmonic 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB 200Hz for QP 150kHz~30MHz / RB 9kHz for QP 30MHz~1000MHz / RB 120kHz for QP Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 16 of 24 -
Report No.: MTi190513E066 5.3.2 Test Procedures a. The measuring distance of at 3 m shall be used for measurements at frequency up to 25GHz. For frequencies above 1GHz, any suitable measuring distance may be used. b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-chamber test. The table was rotated 360 degrees to determine the position of the highest radiation. c. The height of the equipment or of the substitution antenna shall be 0.8m; above 1GHz, the height was 1.5m, the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. f. For the actual test configuration, please refer to the related Item EUT Test Photos. g. For the radiated emission test above 1GHz:
Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. h. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 17 of 24 -
Report No.: MTi190513E066 5.3.3 Test Setup Radiated Emission Test-Up Frequency Below 30MHz Radiated Emission Test-Up Frequency 30MHz~1GHz 5.3.4 Test Result Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 18 of 24 -
Report No.: MTi190513E066 Frequency range (9kHz 30MHz) Temperature:
23.5 Relative Humidity:
66%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 120V/60Hz Test mode:
Mode 1 Frequency
(MHz) 0.0281 0.1454 0.2902 0.4361 Read Level
(dBV) 62.33 77.43 59.23 58.43 Correct Factor Measurement Limits Over
(dBuV/m)
(dBV/m)
(dBV/m) 20.34 19.85 19.75 20.04 82.67 97.28 78.98 78.47 118.56 104.32 98.34 94.81
(dB)
-35.89
-7.04
-19.36
-16.34 Detector QP QP QP QP Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 19 of 24 -
Report No.: MTi190513E066 Frequency range (30MHz 1GHz) Temperature:
25.2 Relative Humidity:
69%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 120V/60Hz Polarization:
Test mode:
Vertical Mode 1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 20 of 24 -
Report No.: MTi190513E066 Temperature:
25.2 Relative Humidity:
69%
Pressure:
Test voltage:
101kPa DC 12V from adapter AC 120V/60Hz Polarization:
Horizontal Test mode:
Mode 1 NoteThe 5V, 9V and 12V operating voltages have been tested and the results show that the 12V operating voltage data is the worst, and the report only shows the worst mode. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 21 of 24 -
Report No.: MTi190513E066 5.4 Occupied bandwidth 5.4.1 Test method Use the following spectrum analyzer settings:
Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel RBW 1% of the 20 dB bandwidth VBW RBW Sweep = auto Detector function = peak Trace = max hold The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to the other side of the emission, until it is (as close as possible to) even with the reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99%
occupied bandwidth of the emission. 5.4.2 Test result Frequency (kHz) 145 20dB emission bandwidth 99% occupied bandwidth
(kHz) 8.147
(kHz) 6.977 Test plots as below Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 22 of 24 -
Report No.: MTi190513E066 Photographs of the Test Setup Radiated emission Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 23 of 24 -
Report No.: MTi190513E066 Conducted emission Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 24 of 24 -
Report No.: MTi190513E066 Photographs of the EUT See the APPENDIX 1: EUT PHOTO in the report No.: MTi190513E066-1.
----END OF REPORT----
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
1 | 18 PSW1-15W-BK RFExp r1 | RF Exposure Info | 225.92 KiB | July 25 2019 |
EXPOSURE REPORT FCC ID: 2ATDP-PSW-15W-BK Date of issue: May 15, 2019 Report Number:
MTi190513E067 Sample Description:
IMPEREA Wireless Charging Pad - Single Station - 15 W - Black Mod el(s):
PSW1-15W-BK Applicant:
Power MP Electronics Co., Ltd. Address:
Unit 04, 7/F, Bright Way Tower, No. 33 Mong KOK Road, Kowlong, HongKong Date of Test:
May 08, 2019 May 15, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Table of Contents Applicants name:
Power MP Electronics Co., Ltd. Address:
Unit 04, 7/F, Bright Way Tower, No. 33 Mong KOK Road, Kowlong, HongKong Manufacture's name:
Power MP(Changping) Electronics Co., Ltd. Address:
Second Industrial Zone, Changping Park, Eastern Industrial Park, Changping Town, Dongguan City, Guangdong Provice, China Product name:
IMPEREA Wireless Charging Pad - Single Station - 15 W - Black Trademark:
Infinite Peripherals Model name:
PSW1-15W-BK Standard:
FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by:
Jone Lee May 15, 2019 Reviewed by:
Blue Zheng May 15, 2019 Approved by:
Smith Chen May 15, 2019 1 General Information 1.1 Description of EUT Product name:
Brand name:
Model name:
Series model:
Deference in serial model:
IMPEREA Wireless Charging Pad - Single Station -
15 W - Black Infinite Peripherals PSW1-15W-BK N/A N/A Operation frequency:
115205 kHz Operational mode:
Wireless charging Modulation type:
Load modulation Antenna type:
Coil antenna Power source:
DC 5V/9V/12V from adapter Battery:
Adapter information:
N/A N/A 1.2 Ancillary equipment list Equipment Adapter Load Model HA832
/
S/N Manufacturer
/
/
ZIMI
/
1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) Radiated emission(30MHz~1GHz) Radiated emission (above 1GHz) Temperature Humidity 2.5 dB 4.2 dB 4.3 dB 1 degree 5 %
2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.:
448573 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E068 Broadband Field Meter Narda Safety Test Solutions GmbH NBM-
520 D-1699 2018/07/13 2019/07/12 MTI-E069 Probe E-Field Narda Safety Test Solutions EF0691 H-0571 2018/07/13 2019/07/12 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power Averaging density(mW/cm2) time(minutes) 0.3-3.0 3.0-30 30-300 300-1500 1500-100000 0.3-1.34 1.34-30 30-300 300-1500 1500-100000
(A) Limits for Occupational/Controlled Exposure 614 1842/f 61.4 1.63 4.89/f 0.163
(B) Limits for General Population/Uncontrolled Exposure 614 824/f 27.5 1.63 2.19/f 0.073
*100
*900/f2 1.0 6 f/300 5
*100
*180/f2 0.2 f/1500 1 6 6 6 6 6 30 30 30 30 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Test Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03:
(1) Power transfer frequency is less than 1MHz.
(2) Output power from each primary coil is less than or equal to 15 watts.
(3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils.
(4) Client device is placed directly in contact with the transmitter.
(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).
(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Note: The device is in compliance with KDB 680106 D01 RF Exposure Wireless Charging App v03 6 conditions. 4.4.3 Test Setup Top Side Back Side Left Side 15cm Right Side Field Probe Front Side Bottom Side 4.4.4 Test Result Battery levels
<1%
<1%
<1%
<1%
<1%
<1%
Battery levels
<50%
<50%
<50%
<50%
<50%
<50%
Battery levels
<99%
<99%
<99%
<99%
<99%
<99%
Maximum permissible Exposure Test sides Test distance(cm) E field(V/m) Hfield(A/m) Top Bottom Left Right Front Back Limit 20 15 15 15 15 15 0.416 0.421 0.426 0.420 0.413 0.412 614 0.112 0.116 0.115 0.106 0.107 0.103 1.63 Margin Limit (%) 0.069%
7.12%
Maximum permissible Exposure Test sides Test distance(cm) E field(V/m) Hfield(A/m) Top Bottom Left Right Front Back Limit 20 15 15 15 15 15 0.425 0.407 0.422 0.414 0.415 0.408 614 0.112 0.115 0.117 0.109 0.114 0.108 1.63 Margin Limit (%) 0.069%
7.12%
Maximum permissible Exposure Test sides Test distance(cm) E field(V/m) Hfield(A/m) Top Bottom Left Right Front Back Limit 20 15 15 15 15 15 0.433 0.423 0.421 0.415 0.422 0.413 614 0.104 0.108 0.110 0.102 0.105 0.119 1.63 Margin Limit (%) 0.071%
7.30%
4.4.5 MPE Setup photo
----END OF REPORT----
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-07-25 | 0.115 ~ PowerOutput | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-07-25
|
||||
1 | Applicant's complete, legal business name |
Power MP Electronics Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0028490555
|
||||
1 | Physical Address |
Unit 04, 7/F, Bright Way Tower
|
||||
1 |
HongKong, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@eurofins.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ATDP
|
||||
1 | Equipment Product Code |
PSW-15W-BK
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G**** G********
|
||||
1 | Title |
PM Manager
|
||||
1 | Telephone Number |
13554********
|
||||
1 | Fax Number |
0769-********
|
||||
1 |
G******@power-mp.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | IMPEREA Wireless Charging Pad - Single Station - 15 W - Black | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Microtest Co., Ltd.
|
||||
1 | Name |
K******** T****
|
||||
1 | Telephone Number |
+8607********
|
||||
1 |
k******@51mti.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.11500000 | 0.20500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC