LinkNet UniServ Unit (USU) RF FIBER Interface Modules Installation, Opera Installation, Operation, tion, Installation, Opera Installation, Opera tion, tion, Maintenance and User Manual Maintenance and User Manual Maintenance and User Manual Maintenance and User Manual DCM000000104 Rev Q September 2005 2005 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies, and the Powerwave logo are registered trademarks. This Powerwave product is intended only for installation in a RESTRICTED ACCESS LOCATION and is designed to operate within the Normal Operating
(typical operating) ranges or conditions specified in this document. Operation of this equipment beyond the specified ranges in this document may cause:
1. Spurious emissions that violate regulatory requirements. 2. The equipment to be automatically removed from service when maximum thresholds are exceeded. 3. The equipment to not perform in accordance with its specifications. It is the Operator's responsibility to ensure this equipment is properly installed and operated within Powerwave operating specifications to obtain proper performance from the equipment and to comply with regulatory requirements. Warnings, Cautions, and Notes Warnings, Cautions, and Notes Warnings, cautions, and notes are found throughout this manual where applicable. The associated icons are used to quickly identify a potential condition that could result in the consequences described below if precautions are not taken. Notes clarify and provide additional information to assist the user. Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical and RF circuitry and be familiar with standard practices for preventing accidents. Caution This caution symbol means reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data. Note This note symbol means reader take note. Notes contain helpful suggestions or references to material not covered in the document. Procedures are not contained in notes. DCM000000104 Rev Q i Revision Record Revision Record Revision Letter Date of Change Reason for Change July 2005 Converted Kaval Rev 15 to Powerwave Format 22 September 2005 Updated with US700PS DCM000000104 Rev Q P Q ii TABLE OF CONTENTS Chapter 1 - Theory of Operation Introduction .................................................................................................................... 1-1 1 1.1 THEORY OF OPERATION ..................................................................................................... 1-1 1.1.1 Typical Application ........................................................................................................... 1-1 MODELS ............................................................................................................................ 1-2 1.2 1.3 TYPICAL BLOCK DIAGRAM................................................................................................... 1-3 Chapter 2 - Mounting Introduction .................................................................................................................... 2-1 LNKFIB-H03 AND LNKFIB-04 HEADEND MODULES ........................................................... 2-1 US REMOTE MODULES....................................................................................................... 2-1 2 2.1 2.2 Chapter 3 - Connections Introduction .................................................................................................................... 3-1 3 3.1 CONNECTIONS ................................................................................................................... 3-1 3.1.1 US Remote Module Connections .................................................................................... 3-2 3.1.2 User I/O Connection ........................................................................................................ 3-3 HEADEND TO REMOTE INTERCONNECTS.............................................................................. 3-4 3.2 3.3 FIBER OPTIC CONNECTIONS ............................................................................................... 3-4 Chapter 4 - Remote Module Introduction .................................................................................................................... 4-1 POWER FOR THE REMOTE MODULE..................................................................................... 4-1 BATTERY BACKUP OF REMOTE MODULE.............................................................................. 4-1 MODULE SPECIFICATIONS................................................................................................... 4-2 REMOTE MODULE PER-CARRIER DERATING ........................................................................ 4-3 4 4.1 4.2 4.3 4.4 Chapter 5 - Operation 5 Introduction .................................................................................................................... 5-1 5.1 OPERATION........................................................................................................................ 5-1 5.1.1 Fault Indications............................................................................................................... 5-1 5.1.2 Configuration and PC Commands ................................................................................... 5-1 GAIN ADJUSTMENTS........................................................................................................... 5-2 5.2 5.3 SIGNAL LEVEL ADJUSTMENTS ............................................................................................. 5-2 Chapter 6 - Antenna Installation Introduction .................................................................................................................... 6-1 ANTENNA INSTALLATION ..................................................................................................... 6-1 FCC INFORMATION TO USERS ............................................................................................ 6-1 Chapter 7 - Laser Safety Introduction .................................................................................................................... 7-1 LASER SAFETY................................................................................................................... 7-1 6 6.1 6.2 7 7.1 Chapter 8 - Return For Service 8 Introduction .................................................................................................................... 8-1 8.1 RETURN FOR SERVICE PROCEDURE ................................................................................... 8-1 8.1.1 Obtaining An RMA ........................................................................................................... 8-1 8.1.2 Repackaging For Shipment ............................................................................................. 8-1 8.2 PARTS AND ACCESSORIES.................................................................................................. 8-1 DCM000000104 Rev Q iii Table of Contents TABLE OF FIGURES Figure 1 Typical Application ......................................................................................................... 1-1 Figure 2 Typical Block Diagram.................................................................................................... 1-3 Figure 3 US Remote Modules ...................................................................................................... 1-4 Figure 4 US Remote Modules Mounting ...................................................................................... 2-1 Figure 5 Power Supply Module and Mounting ............................................................................. 2-2 Figure 6 LNKFIB-H03/H04 Headend Module (Front) ................................................................... 3-1 Figure 7 LNKFIB-H03/H04 Headend Module (Rear).................................................................... 3-1 Figure 8 LNKFIB-H03/H04 Headend Module Drawing (Rear) ..................................................... 3-1 Figure 9 US Remote Module Connections................................................................................... 3-2 Figure 10 ASY00420 DB15 Breakout Kit ..................................................................................... 3-3 Figure 11 Remote Module (Rear View)........................................................................................ 3-3 TABLE OF TABLES Table 1 Available Models and Descriptions ................................................................................. 1-2 Table 2 Module Specifications...................................................................................................... 4-2 Table 3 Per-Carrier Derating ........................................................................................................ 4-3 iv DCM000000104 Rev Q Chapter 1 Theory of Operation Chapter 1 Chapter 2 Chapter 3 Chapter 4 Theory of Operation Mounting Connections Remote Module 1 Introduction This manual contains information and procedures for installation, operation, and maintenance of the LinkNet Uniserv Unit RF-FIBER Interface Modules. The manual is organized into the following chapters:
1.1 Theory of Operation The USU RF to Fiber Modules provides a single-band link from a Headend distribution center to multiple local antennae. RF signals are distributed over a pair of single mode fiber optic distribution lines to each USU Remote. Each Headend module can interface to multiple remote modules, the number depending upon the Headend model. The Headend modules do not transmit directly out into the air. Note! The remote module fiber optic I/O's are band specific, but the Headend fiber optic I/O's are not;
Operation Antenna Installation Laser Safety Return for Service Chapter 5 Chapter 6 Chapter 7 Chapter 8 the Headend I/O's may be used for any band. 1.1.1 Typical Application A typical installation would be.... Any required Amplifiers, Filters, Couplers, Etc. RF Cable to/from Base Station(s) RF Cables Head-End Module Head-End Module Head-End Module Head-End Module Head-End Module SMF = Single-Mode Optical Fiber USU RF to Fiber Remote Modules These may be single or multiple units, and are usually grouped on floors of a building, mounted in Electrical Rooms. In-Building Antennae Refer to Antenna Installation Section SMF SMF SMF SMF SMF SMF SMF SMF SMF SMF RF Cable RF Cable RF Cable RF Cable RF Cable HEAD-END DISTRIBUTION CENTER REMOTE LOCATIONS IN BUILDING Figure 1 Typical Application DCM000000104 Rev Q 1-1 Models 1.2 Models Table 1 Available Models and Descriptions DESCRIPTION Wall, shelf, or rack mounted remote module that connects to the single mode fiber optic distribution line and provides a single duplex antenna RF distribution connection. This model covers 800MHz Trunking / iDEN / Public-Safety Services
(806-824 MHz / 851-869 MHz). As above, but this model covers 800MHz Cellular Services
(824-849 MHz / 869-894 MHz) As above, but this model covers 900MHz Paging Services
(896-902 MHz / 928-941 MHz) As above, but this model covers 1.9GHz PCS Services
(1850-1910 MHz / 1930-1990 MHz). As above, but this model covers 1.8GHz GSM Services
(1710-1785 MHz / 1805-1880 MHz). As above, but this model covers 900MHz GSM Services
(890-915 MHz / 935-960 MHz). As above, but this model covers 700MHz GSM Services
(764-776 MHz in DL / 794-806 MHz in UL). MODEL US800TP USU Remote Module US800C USU Remote Module US900P USU Remote Module US1900P USU Remote Module US1800G USU Remote Module US900G USU Remote Module US700PS USU Remote Module Note that for each model above there is a model with a "-2" suffix. These extra models have separate Rx and Tx RF Ports instead of a combined transceiver
(antenna) port. US-PS01 Power supply for 1 US remote module. This is a 1U high, 19" rack-mount module providing low signal level interfacing between Headend RF modules and 8 pairs of single mode fiber optic distribution lines. The 8 fiber optic pairs are in two groups of four, with the RF connections combined inside the module in those groupings. This is a 1U high, 19" rack-mount module providing low signal level interfacing between Headend RF modules and 4 pairs of single mode fiber optic distribution lines. The RF connections for the 4 fiber optic pairs are combined inside the module. LNKFIB-H03 Headend Module LNKFIB-H04 Headend Module 1-2 DCM000000104 Rev Q 1.3 Typical Block Diagram Typical Block Diagram Micro-Controller Circuitry Green Power On LED Red Fault LED CAN Interface To Head-End RS232 Interface To PC RF Out "A"
Fault Relay Power Supply 120 / 240 VAC 120/240 VAC Photodetectors & PreAmps W ith UpLink Gain Control RF Input "A"
Laser Diode PreAmp SM F.O. In
(PIN Diodes) SM F.O. Out
(Lasers) RF Out "A"
Photodetectors & PreAmps SM F.O. In
(PIN Diodes) W ith UpLink G ain Control RF Input "A"
Laser Diode PreAmp SM F.O. Out
(Lasers) Figure 2 Typical Block Diagram In the LNKFIB-H03 Headend module, the eight fiber optic pairs are in two banks (A & B) of four, with the RF connections combined inside the module in those groupings. The LNKFIB-H04 is identical, but with one bank of four removed. Each of the groups of four consists of a single RF Input feeding a single Laser Transmitter split optically to four fiber optic outputs. The four matching fiber optic Inputs each go to their own photodiode receiver, followed by a 0 to -15dB digitally controlled attenuator providing uplink gain control. The RF signals from the four digital attenuators are combined into a single RF output. The group of four RF input and output combining inside the module alleviates the need for external combining / splitting. DCM000000104 Rev Q 1-3 US Remote Typical Block Diagram Figure 3 US Remote Modules The US series remote modules have a fiber optic transceiver pairs, downlink and uplink filtering, and a downlink RF power amplifier. 1-4 DCM000000104 Rev Q Chapter 2 Mounting 2 Introduction This chapter contains mounting information for the LinkNet Uniserv Unit RF-FIBER Interface and Remote Modules. 2.1 LNKFIB-H03 and LNKFIB-04 Headend Modules These headend modules are intended for mounting in standard 19 racks. 2.2 US Remote Modules The US remote modules may mount upon horizontal or vertical panels made of either wood or metal. If mounted on vertical panels, they must be mounted sideways so that the fiber optic and electrical connections do NOT face either up or down. The Remote Modules are secured with six mounting screws or bolts as shown... Figure 4 US Remote Modules Mounting DCM000000104 Rev Q 2-1 Power Supply Module and Mounting The US-PS01 power supply is a combination of a modular switching power supply and a mounting bracket, also intended to mount upon horizontal or vertical panels made of either wood or metal. Figure 5 Power Supply Module and Mounting 2-2 DCM000000104 Rev Q Chapter 3 Connections 3 Introduction This chapter contains connection information for the LinkNet Uniserv Unit RF-FIBER Interface Modules. It is important to perform the following:
Carefully read all material in this chapter prior to equipment installation. Review any government and local codes as they apply to your installation. 3.1 Connections Figure 6 LNKFIB-H03 Headend Module (Front) Figure 7 LNKFIB-H03 Headend Module (Rear) The LNKFIB-H03 Headend has two downlink RF Inputs providing the signal for eight downlink optical outputs arranged as groups of four, "A" and "B". It also has eight uplink optical inputs, combined in two groups of four, providing RF outputs "A" and "B". The RF and optical connections are all on the rear panel. The group of four RF input and output combining inside the module alleviates the need for external combining / splitting. Figure 8 LNKFIB-H03 Headend Module Drawing (Rear) The CAN, RS232, and Fault Relay Interface connections are all on the front panel. Their connections are;
RS232 Connection:
The RS232 Port is for interfacing to a PC via a Null-Modem DB9 female to female cable, and operates at 9600 baud, 8 bits, no parity, and 1 stop bit. It is a 3-wire connection. DB9 Pin #
Signal RS232 Receive RS232 Transmit Ground 2 3 5 DCM000000104 Rev Q 3-1 DB15 Pin #
US Remote Module Connections User I/O Connection:
This Connection is via a standard 15-pin female D-Sub connector on the side of the enclosure... The Form-C Relay is rated at 30 VDC @ 1 Amp or 30 VAC @ 0.5 Amp. Refer to the DCM000000103 CAN Wiring Guide. Signal CAN High CAN Low CAN Common (Ground) Fault Relay Common Fault Relay - Closed for Fault Fault Relay - Open for Fault 1 9 8 3 2 4 3.1.1 US Remote Module Connections Figure 9 US Remote Module Connections The Remote Module has 1 or 2 SMA RF connections.. RF Xcvr:
RF Tx & Rx:
Fiber-Optic Ports:
RS232 Connection:
For the normal (non -2) models there is a single RF transceiver port used to connect to a distributed indoor antenna system. For the 2-Port (-2) models there are RF transmit and receive ports used to connect to external filtering and combining, then to a distributed indoor antenna system. Consult Powerwave for details. There are two SC/APC single mode fiber optic connections for cabling to the Headend. There is a RS232 connection via standard 9-pin female D-Sub connector. It is wired as;
DB9 Pin # Signal DCD in 1 Transmit 2 3 Receive 5 Ground RS232 is for interfacing to a PC via a straight-through DB9 male to female cable, and operates at 9600 baud, 8 bits, no parity, and 1 stop bit. DSR CTS in RTS out RI in 6 7 8 9 USB Connection: To use the USB port on the USU, a virtual COM port driver must first be installed using the driver CD-ROM shipped with the USU. This virtual COM port driver will create a new COM port that will use the next available port number. For example, if your PC has two COM ports, the virtual COM port driver will create a COM3 port. Follow the instructions on the CD to install the driver. DCM000000104 Rev Q 3-2 User I/O Connections DB15 Pin #
1 9 8 2 3 5 6 7 10 11 12 13 14 15 3.1.2 User I/O Connection This is a standard 15-pin female D-Sub connector. The Form-C Relay is rated at 30 VDC or 30 VAC @ 0.5 Amp. The auxiliary lines are under custom software control. Refer to the DCM000000103 CAN Wiring Guide. Note! The ASY00420 DB15 Breakout Kit may be ordered to bring the User I/O connections Signal CAN High CAN Low CAN Common Fault Relay - Closed for Fault Fault Relay Common Fault Relay - Open for Fault
+28 VDC at up to 0.5 Amp Ground Aux. In #1 (contact to ground) Aux. In #2 (contact to ground) Aux. In #3 (contact to ground) Aux. Out #1 (open collector) Aux. Out #2 (open collector) Aux. Out #3 (open collector) out to screw terminals for easy wiring. Figure 10 ASY00420 DB15 Breakout Kit This 4" x 4" board mounts onto four 3.5" x 3.5" #6 locations, and includes a 6' DB15 to DB15 cable. At the rear of the remote unit are the power and battery connections... Figure 11 Remote Module (Rear View) DCM000000104 Rev Q 3-3 Headend to Remote Interconnections 3.2 Headend to Remote Interconnects The single mode fiber optic interconnections between the Headend and Remote modules are to be made in whatever manner suits the system configuration. For the CAN Network connections please refer to DCM000000103. 3.3 Fiber Optic Connections All Fiber Optic Cabling must use 9/125 or similar Single-Mode (yellow jacketed) high-
quality cable. This cable should typically have less than 0.5 dBo (optical dB) insertion loss per kilometer. The cable manufacturer's minimum bend radius must be observed. Most Powerwave products use SC/APC connectors. Note that the "APC" is critical. These are angle-polished connectors and are required to reduce reflections. Fiber-Optic Patchcords should be avoided; Fusion-Splices are preferred to reduce reflections. Fiber-Optic Connectors, both on cables and equipment, should always have their dust caps in place when not in use. The connector tips must be kept clean and scratch free, and should always be cleaned properly before being connected. Optical Reflections back into laser diodes cause a disturbance in the lasers gain cavity creating noise and distortion. An OTDR or other fiber optic instruments should be used to check optical reflections. Fiber optic return loss should be less than -50 dBo. There is a 2 to 1 Relationship between optical loss and RF loss. One dBo (optical dB) of optical loss corresponds to 2 dB of RF loss. 3-4 DCM000000104 Rev Q Chapter 4 Remote Module 4 Introduction This chapter contains specifications and information for the LinkNet Uniserv Unit RF-FIBER Remote Modules. 4.1 Power for the Remote Module The US remote module may be powered by any source of negative ground +28VDC power capable of delivering 1 Ampere. This includes the optional single US remote module US-PS01 power supply. 4.2 Battery Backup of Remote Module If the US remote module is being used without a battery it must be configured to NOT use a battery. Without a battery the USU will shut down or reset with any disruption to the AC power. When power is re-established the system will restart automatically. External batteries may be connected using the CAB000000055 Battery Cable. The USU has a built-in battery charger that will automatically recharge the attached battery. Refer to DCM000000102 "Battery Backup Manual". For Battery Backup purposes:
Vbat = 24 VDC Id = 0.75 Ampere Ic = 0.1 Ampere DCM000000104 Rev Q 4-1 Module Specifications 4.3 Module Specifications Table 2 Module Specifications Frequency Bands Maximum Downlink Power Maximum Uplink Power Combined at any Headend RF Output. Includes the 4-way combiner loss. Downlink Gain from Headend to the Remote Module Antenna Port, assuming 0dB Fiber-Optic Link Downlink Gain Ripple Uplink Gain from Remote Module Antenna Port to Headend, assuming 0dB Fiber Optic Link Uplink Gain Ripple Max RF Input without Damage To Headend Units Uplink Noise at Headend Unit from any Remote Module Antenna Port assuming 0dB Fiber Optic Link Isolation Duty Cycle Spurious Outputs Optical Power Level Optical Path Loss Group Delay Connectors Headend Module Power Supply Requirements Remote Module Power Supply Requirements US-PS01 Power Supply Requirements Configuration Options Operating Temperature Range Operating Humidity Range Headend Module Size & Weight Remote Module Size & Weight FCC Identifiers Industry Canada Certifications 4-2 Refer to Model Chart
+38 dBm IP3 Min. iDEN/Cell/Page/GSM900/700PS
+36 dBm IP3 Min. for PCS, GSM1800
(see Remote Module Carrier De-Rating Chart)
+4 dBm IP3 Min., iDEN/Cell/Page/GSM900/700PS 0 dBm IP3 Min., PCS/GSM1800
(7 to 12dB higher for LNKFIB-H01)
+20 dB after Gain Adjustment Typical range before Gain Adjust is
+20 to +35 dB for 700-900 MHz Bands
+20 to +31dB for 1.8-1.9 GHz Bands
(See Gain Adjustments)
+/- 3.5 dB over entire Band
+20 dB after Gain Adjustment Typical range before Gain Adjust is
+20 to +32 dB for 700-900 MHz Bands
+20 to +32dB for 1.8-1.9 GHz Bands
(See Gain Adjustments)
+/- 3.5 dB over entire Band
+10 dBm
< -130 dBm/Hz
(with Uplink Gains Balanced) Consult Powerwave Engineering Services
(depends upon Headend Filtering) Continuous
-20 dBm max per Remote Module Antenna Port when operated as per Derating Chart Laser Warning: Invisible Laser Radiation emitting from optical connector. Avoid direct exposure to beam. 150 mW max. @1300nm. Class IIIb. Product complies with 21 CFR 1040.10 and 1040.11. 2 dBO Maximum
<2uS, NOT including Fiber Optic Link SC/APC Fiber Optic, SMA (50) RF D-Sub, USB, Data & Control 120/240 VAC, 50/60 Hz, 75 VA Typical, 90 VA Max. 28 VDC from external Power Supply, 0.75A Max and 24VDC "Gell-Cell" Battery Backup Option 120/240 VAC, 50/60 Hz, 30 VA Typical, 70 VA Max. Either via the USU network and a Gateway Module, or via a PC and an RS-232/USB Connection.
-20 to +50oC 5 to 90% RH, Non-Condensing 1U High 19 Rack Unit, 14" Deep, 16 lbs Max 2.75 High, 9.25 Wide, 11 Deep, 6 lbs Max 70mm(H), 235mm(W), 280mm(D), 2.7Kg Max. FCC: H6M-US800TP FCC: H6M-US800C FCC: H6M-US900P FCC: H6M-US1900P IC: 1541A-US800TP IC: 1541A-US800C IC: 1541A-US900P IC: 1541A-US1900P DCM000000104 Rev Q Remote Module Per-Carrier Derating 4.4 Remote Module Per-Carrier Derating All signals that fall within a given Pass-Band range will share power amongst them. A multiple channel effect is intermodulation, signals produced from non-linear effects between the intended channel signals. This intermodulation may cause interference to receiving equipment. In order to minimize intermodulation signals, power de-rating must be applied. In the USA there are FCC Intermodulation Specifications published in the EIA Standard PN2009. Further derating is also required to maintain the integrity of complex digital communications signals. The table below gives the maximum per channel output levels allowed as a function of the number of channels. Note that depending on the actual input levels, the gain may need to be reduced to comply with the above regulations. The figures shown are to the nearest dB. Table 3 Per-Carrier Derating iDEN / Cellular / Paging/GSM900/700PS
(effective IP3 = +38dBm) 1.9 GHz PCS/1.8GHz GSM
(effective IP3 = +36dBm) Number of Carriers 1 2 3 4 5 6 7 8 9 10 15 20 25 30 Note!
Digital Number of Carriers Total Power per Antenna Port (dBm) Total Power per Antenna Port (dBm) Power per Carrier per Antenna Port (dBm) Power per Carrier per Antenna Port (dBm) FM Dig
+17
+24
+15
+15
+14
+13
+11
+13
+9
+12
+8
+11
+10
+7
+6
+9
+5
+8
+7
+4
+2
+5 0
+3
+2
-1
+1
-2 The above levels are shown for both FM and Digital (CDMA, TDMA, GSM, & iDEN) Signals for 700-900 MHz, and Digital only for 1.9 GHz PCS/1.8 GHz GSM. Some combinations may require additional Derating. Consult Powerwave Technologies Inc. for further information. Digital
+15
+13
+11
+9
+8
+7
+6
+5
+4
+3
+1
-1
-2
-3 Digital
+15
+16
+16
+15
+15
+15
+14
+14
+14
+13
+13
+12
+12
+12 FM
+24
+18
+18
+19
+19
+19
+18
+18
+18
+17
+17
+16
+16
+15 Dig
+17
+18
+18
+17
+16
+16
+15
+15
+15
+14
+14
+13
+13
+13 1 2 3 4 5 6 7 8 9 10 15 20 25 30 DCM000000104 Rev Q 4-3
(This page intentionally left blank) 4-4 DCM000000104 Rev Q Chapter 5 Operation 5 Introduction This chapter contains operational and standard safety information for the LinkNet Uniserv Unit RF-FIBER Interface Modules. 5.1 Operation Normal operation for both USU Headend and Remote modules:
POWER / OPERATING - GREEN when the module is operating. FAULT Red if the internal diagnostics detect a problem. LASERS ON - GREEN when any one of the lasers are operating. 5.1.1 Fault Indications Each module continuously performs internal diagnostics. If a problem is detected it will activate its Red Fault LED and Fault Relay. Faults detected include;
Over Temperature. Misc. Internal Faults. Detailed faults are detected by the optional Gateway Module. Details may also be determined via an RS232 connected Terminal Emulator using the LIST command. 5.1.2 Configuration and PC Commands It is possible to re-configure modules in the field, either with a personal computer (PC) or via the optional LinkNet Gateway Module. To use a PC it is necessary to connect the DB9 RS-232/USB connector on the module to a standard DB9 RS232/USB connector on the PC. On the PC a terminal emulation program such as HyperTerminal is used to communicate to the LinkNet module. The settings are 9600 baud, 8 bits, no parity, and 1 stop bit. Commands are one or two words followed by pressing Return. Commands may be given in upper or lower-case. Available commands are listed below for each module. Headend Modules:
ACCESS USER:
Required as a simple password to gain access to customer settable parameters and diagnostics; This times-out after 10 minutes, and may have to be retyped. Displays a list of Available Commands. Displays Current Settings and Status Faults, Etc. Display the current Version of Software. Enables or Disables the Module. Displays or Sets the Uplink Gain Reduction yyy, which is in tenths of a dB. The Optical to RF Path being set is x, which is;
x = 0 x = 1 x = 2 x = 3 x = 4 x = 5 x = 6 x = 7 is for Uplink Optical to RF Path A1 is for Uplink Optical to RF Path A2 is for Uplink Optical to RF Path A3 is for Uplink Optical to RF Path A4 is for Uplink Optical to RF Path B1 is for Uplink Optical to RF Path B2 is for Uplink Optical to RF Path B3 is for Uplink Optical to RF Path B4 HELP or ?:
LIST:
VER:
ENABLE 1 or 0:
DIGATTN x yyy:
DCM000000104 Rev Q 5-1 Configuration and PC Commands Remote Modules:
ACCESS USER:
Required as a simple password to gain access to customer settable parameters and diagnostics; This will time-out after 10 minutes, and may have to be re-typed. Displays a list of Available Commands. Displays Current Settings and Status Faults, Etc. Display the current Version of Software. Enables or Disables the Module. Displays or Sets the Downlink Gain Reduction, which is in tenths of a dB. HELP or ?:
LIST:
VER:
ENABLE 1 or 0:
DLGATTN ###:
Please consult Powerwave Technologies Inc. for further support. 5.2 Gain Adjustments Gain adjustment is necessary to compensate for the variations in the fiber optic components of the Headend and Remote modules. This must be done after modules are deployed in a system, and anytime a module is replaced. The adjustments are on an individual RF path basis, and each path is adjustable downwards in 1dB steps up to -15dB. It is recommended that these adjustments be performed with the aid of a Signal Generator and Spectrum Analyzer. Uplink Gain:
The uplink gain is adjusted at the Headend module on an individual RF path basis. Please refer to the Headend DIGATTN commands in the Configuration and PC Commands section. All DIGATTN values are set to 0 (Maximum RF Gain). While monitoring the RF gain via measurements, the individual gain paths are adjusted downwards with the DIGATTN command to meet the specified gain. This will optimize/balance both gain and noise. Downlink Gain:
The downlink gain is adjusted at the remote module an individual RF path basis. Please refer to the remote DLGATTN commands in the Configuration and PC Commands section. All DIGATTN values are set to 0 (Maximum RF Gain). While monitoring the RF gain via measurements, the individual gain paths are adjusted downwards with the DLGATTN command to meet the specified gain. This will optimize/balance both gain and noise. 5.3 Signal Level Adjustments Signal level adjustment is necessary to ensure that the downlink RF carriers transmitted via the remote modules are not generating undesired intermodulation products, nor are they being distorted beyond use. Refer to the earlier section on Remote Module Per-Carrier Derating. It is recommended that these adjustments be performed with the aid of a Signal Generator and Spectrum Analyzer, and that they be done AFTER the gain adjustments. Adjust the downlink interface amplifiers and/or attenuators between the base stations and the Headend modules (see the Typical Application drawing) to achieve the specified derated per-carrier level. Uplink signals should be monitored as they feed into the base station, this is usually a site specific requirement. 5-2 DCM000000104 Rev Q Chapter 6 Antenna Installation 6 Introduction This chapter contains antenna installation and warning information for the LinkNet Uniserv Unit RF-FIBER Interface Modules. 6.1 Antenna Installation All Antenna installation to be performed by qualified technical personnel only. Antenna installation instructions and locations below are for the purpose of satisfying The In-Building Antenna or Antennae connection is via a coaxial cable distribution system FCC RF Exposure Compliance requirements. connected to the fixed-mounted Indoor Antennae. The Indoor Antennae are simple 1/4 wavelength (0 dB Gain) types. These antennae are to be installed such that no person can touch the antenna, or approach within 0.2 Meters. ANTENNA INSTALLATION CAUTION ALL ANTENNA INSTALLATION IS TO BE PERFORMED BY QUALIFIED TECHNICAL PERSONNEL ONLY. ANTENNA INSTALLATION INSTRUCTIONS AND LOCATIONS ARE FOR THE PURPOSE OF SATISFYING FCC RF EXPOSURE COMPLIANCE REQUIREMENTS, AND ARE NOT OPTIONAL. ALL IN-BUILDING ANTENNAE INSTALLATIONS MUST BE SUCH THAT NO PERSON CAN TOUCH THE ANTENNAE, OR APPROACH CLOSER THAN 0.2 METERS. Please consult Powerwave Technologies Inc. for assistance as required. 6.2 FCC Information to Users This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY POWERWAVE TECHNOLOGIES INC. COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. DCM000000104 Rev Q 6-1
(This page intentionally left blank) 6-2 DCM000000104 Rev Q Chapter 7 Laser Safety 7 Introduction This chapter contains laser safety information for the LinkNet Uniserv Unit RF-FIBER Interface Modules. 7.1 Laser Safety CAUTION use of controls or adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure. This laser product is certified as a CLASS I laser product to the requirements of the US Federal Product Performance Standard for Laser Products contained in the regulations in 21 CFR Subchapter J. Class I laser products are not considered to be hazardous. This laser product incorporates a Class IIIb laser module, which generates levels of invisible laser radiation that may be hazardous. However, this machine incorporates protective housing and optical fibers in the machine design such that there is no exposure or human access to laser radiation when the product is properly installed. All optical output connections to the LinkNet Uniserv Unit (USU) must either have UNDER NO CIRCUMSTANCE shall attempts be made to operate this system an optical fiber connected or be capped. without the optical fibers connected or with caps removed from the optical output connectors. All service to the LinkNet UniServ Unit (USU) shall be performed by Powerwave Technologies Inc. service personnel, their authorized agents, or personnel trained by Powerwave Technologies Inc. DCM000000104 Rev Q 7-1
(This page intentionally left blank) 7-2 DCM000000104 Rev Q Chapter 8 Return for Service 8 Introduction This chapter contains return for service and parts & accessories information for the LinkNet Uniserv Unit RF-FIBER Interface Modules. 8.1 Return For Service Procedure Please contact Powerwave Technologies Inc. for a copy of the Standard Product Warranty. When returning products to Powerwave Technologies Inc., the following procedures will ensure optimum response. 8.1.1 Obtaining An RMA A Return Material Authorization (RMA) number must be obtained prior to returning equipment to the factor for service. Please contact our Repair Department at +1 (714) 466-1000 to obtain this number, or FAX your request to +1 (714) 466-5816 or mailto:RMA@PWAV.COM. Failure to obtain this RMA number may result in delays in receiving repair service. 8.1.2 Repackaging For Shipment To ensure safe shipment of the amplifier, it is recommended that the original package designed for shipping the amplifier be reused. If it is not available, contact Powerwave Technologies Inc. Customer Service Department for packing materials. 8.2 Parts and Accessories Parts and accessories for the LinkNet UniServ Unit RF-FIBER Interface Modules may be purchased by contacting Powerwave Technologies Inc. at 1-888-PWR-WAVE. When ordering a replacement part, please provide model number, serial number and software version number. DCM000000104 Rev Q 8-1
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2005-11-17 | 764 ~ 776 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2005-11-17
|
||||
1 | Applicant's complete, legal business name |
Powerwave Technologies Inc
|
||||
1 | FCC Registration Number (FRN) |
0006343024
|
||||
1 | Physical Address |
1801 E St Andrew Pl.
|
||||
1 |
Santa Ana, California 92705
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
E67
|
||||
1 | Equipment Product Code |
5JS0079
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** D******
|
||||
1 | Title |
Principal Reliability Engineer
|
||||
1 | Telephone Number |
714 4********
|
||||
1 | Fax Number |
714 4********
|
||||
1 |
j******@pwav.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LINKNET UNISERV UNIT BOOSTER | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted per carrier. The antenna(s) used for this transmitter must be fixed-mounted on permanent structures with a separation distance from all persons and maximum antenna gain of 20 cm and 0dBd. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of 1.1307(b)(3), for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UltraTech Engineering Labs Inc.
|
||||
1 | Name |
T******** L****
|
||||
1 | Telephone Number |
877-7********
|
||||
1 | Fax Number |
905-8********
|
||||
1 |
t******@ultratech-labs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 9 | 764 | 776 | 0.25 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 2 | 9 | 764 | 776 | 0.25 | Amp | F1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC