G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 G3 MASTHEAD AMPLIFIER INSTALLATION AND OPERATING MANUAL The information contained in this document is furnished in commercial confidence and upon the condition that the individual and corporate rights originating in the information, whether patented or not, will be respected. Reference: 00/OSM/0002 Date: May 2000 Issue: 1 Prepared by:
Authorised by Engineering:
Authorised by Quality:
Ranjit S Manku REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 1 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 HISTORY DATE 18/05/00 ISSUE 1 AUTHOR MOD/ISSUE NOTE Ranjit S Manku ECO 1262 First Issue NOTES REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 2 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 CONTENTS 1.1.1 1.1.2 Reference....................................................................................................................................................5 System Description.......................................................................................................................5 System Operation..............................................................................................................7 Interfaces ............................................................................................................................9 Hardware Description................................................................................................................ 20 Masthead Amplifier ........................................................................................................ 20 Power Distribution Unit................................................................................................. 20 Bias Tee........................................................................................................................... 21 Cable Kit........................................................................................................................... 21 MHA Mounting Kit............................................................................................................ 21 1.2.1 1.2.2 1.2.3 1.2.4 1.2.5 1.1.1 1.1.2 1.2.1 1.1.2 1.1.3 1.1.4 1.1.5 Installation Manual................................................................................................................................. 22 General......................................................................................................................................... 22 Recommended RF Cable Installation Components .............................................. 23 Installation Summary and Mounting Configuration ................................................. 23 Installation of Masthead Amplifier (MHA) ............................................................................... 26 General Mounting Instructions..................................................................................... 26 Detailed MHA Installation Procedure.......................................................................... 27 Installation of Bias Tee.................................................................................................. 33 Installation of Power Distribution Unit........................................................................ 33 Installation of Cables..................................................................................................... 34 Grounding Cables and Lightning Protection......................................................................... 34 Clamping of cables and correct Grounding.............................................................. 34 Ground Path Requirements ......................................................................................... 34 Grounding/Earthing of the MHA................................................................................... 34 Schematic of Lightning Protection circuit................................................................... 35 Basic Grounding/Earthing: Good Practice................................................................. 35 Installation Measurements ....................................................................................................... 36 A Method of measurement of Static Gain of the MHA.............................................. 36 Effects of Cable Length on the Noise Figure............................................................ 37 The effects of introducing REMEC-Airtech G3 MHA................................................. 37 The Effect of Auxiliary attenuator in the Rx path ........................................................ 38 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.4.1 2.4.2 2.4.3 2.4.4 Operation and Maintenance ................................................................................................................ 40 Set-up and Test.............................................................................................................. 40 Fault Finding and Repair Procedures ........................................................................ 40 MHA to Ground Equipment DC circuit Test............................................................... 42 3.1.1 3.1.2 3.1.3 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 Variable Gain MHA Option .................................................................................................................... 49 Hardware Description................................................................................................................ 49 Variable Gain Masthead Amplifier............................................................................... 49 Power Distribution Unit................................................................................................. 50 Bias Tee........................................................................................................................... 50 Cable Kit........................................................................................................................... 50 Mounting Kit..................................................................................................................... 51 Antenna Line Protocol Modem Kit............................................................................... 51 Installation of Variable Gain MHA............................................................................................ 52 Operation and Maintenance of Variable Gain MHA.............................................................. 52 Gain Setting of the Variable Gain MHA....................................................................... 52 4.3.1 1.1 1.2 2.1 1.2 2.3 2.4 4.1 4.2 4.3 Frequently Asked Questions ............................................................................................................... 55 Lightning Protection Circuit....................................................................................................... 55 Mounting and Maintenance....................................................................................................... 58 5.1 5.2 Glossary.................................................................................................................................................... 59 1 2 3 4 5 6 REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 3 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Table of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 MHA System Interconnection Diagram with Bias Tees............................................... 6 Masthead Amplifier Circuit Schematic...................................................................... 8 Masthead Amplifier Interfaces.................................................................................. 9 Power Distribution Unit Interfaces (Indoor)................................................................12 Power Distribution Unit Interfaces (Outdoor).............................................................13 Bias Tee Cable Kit for Outdoor PDU........................................................................15 Bias Tee Interfaces................................................................................................16 PDU DC Output port to Bias Tee ............................................................................17 PDU Alarm port to BTS Alarm ................................................................................18 Mounting Bracket Kits ...........................................................................................19 G3 MHA - Typical Mounting Configuration................................................................25 Flat Surface and Pole Mounting of a Single MHA .....................................................27 Flat Surface or Pole Mounting of Stacked Dual MHAs ..............................................28 Installation of the MHA using a Single-MHA Mounting Bracket kit.............................31 Interface Drawing of G3 MHAs................................................................................32 A Schematic of a Lightning Protection Circuit ..........................................................35 DC Circuit Test Kit D...........................................................................................43 Test Kit Configuration during confidence test............................................................44 Flow Chart 1 ~ Test Kit D confidence test................................................................45 Operating Current Test for a System without Bias Tee or BTS ...................................46 Operating Current Test for a System with a Bias Tee but without a BTS .....................47 Operating Current Test for a System with a Bias Tee and BTS connected ..................48 Antenna Line Protocol Modem................................................................................51 MHA Management Terminal Window on Laptop PC..................................................53 MHA Gain Adjustment using ALP Modem and Laptop PC.........................................54 REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 4 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1 Reference 1.1 System Description The REMEC-Airtech Masthead Amplifier (MHA) system is used within the DAMPS800, GSM900, DCS1800 and PCS1900 band to enhance the reception sensitivity of the BTS. The MHA improves the uplink balance from the hand portable. This is achieved by the installation of a Low Noise Amplifier in close proximity to the BTS antenna. The MHA provides 12dB of gain to amplify the uplink signal from the portable subscriber handset. The addition of the amplifier at the masthead maximises the signal available to the BTS by overcoming the losses introduced by the BTS feeder cable. The MHA provides major benefits in performance by matching both the 'downlink' and uplink coverage. The historical imbalance caused by the lower handset output power is corrected by the MHA Rx signal improvement. The three sector MHA system comprises the following units:
Description Product Code Quantity G3 MHA - duplexed RF / Bias Tee feed DAMPS800, GSM900, DCS 1800 or PCS 1900 MHz frequency as applicable G20xxx (DAMPS800) G20xxx (GSM900) N20xxx (DCS1800) S20xxx (PCS1900) 6 (2 per Sector ) MHA Mounting Kit Single-MHA mounting Dual-MHA mounting G3 PDU -48v (19 rack mount for Bias Tee)
(+ve ground / 24v / external optional) Single Bias Tee Assembly (Indoor)
(External Bias Tee optional) N04xxx N0403601 N02xxx G03xxx (DAMPS800) G03xxx (GSM900) N03xxx (DCS1800) S03xxx (PCS1900) Cable Set (to suit individual installation) N05xxx Antenna Line Protocol Model Kit (to use with VG MHA) N26001A1 DC Circuit Test Kit D N0402901 6 (2 per Sector ) 3 (1 per sector) 1 6 1 NOTE:
If the Variable Gain Masthead Amplifier is installed without Booster PDU, an Antenna Line Protocol Modem Kit will be required to set the gain of the MHA. A System Interconnection diagram is shown in Figure 1. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 5 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Figure 1 MHA System Interconnection Diagram with Bias Tees REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 6 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.1.1 System Operation The MHA system is used to enhance the uplink radio path from the remote subscriber to the BTS. The MHA has been designed for the simple upgrade of an existing DAMPS800, GSM900, DCS1800 or PCS 1900 cellular network or for the improved cost-effectiveness of initial Network roll-out by the addition of a Low Noise Amplifier at the masthead with minimum cable loss from the antenna. The MHA accepts a single BTS and Antenna feeder cable such that the unit can be fitted in-line with the existing cable at the masthead. The unit utilises a Bias Tee power feed arrangement to enable the supply to be fed through the RF coaxial cable without the need for any further cable installation for site upgrade. The MHA is fitted with high performance low loss/high selectivity duplexers to enable the transmit RF to pass from BTS to Antenna with < 0.5dB loss. The duplexers ensure high Tx/Rx isolation, enabling the reception of low level signals from the mobile. The LNA is fitted between the Rx duplexer filters to provide approximately 12dB of Rx signal gain. The LNA comprises two low noise GaAs FET amplifiers operating in parallel for improved reliability and higher IP3 performance. A BITE detection circuit is fitted for LNA fault detection with an RF bypass circuit becoming operational upon a total LNA failure, i.e. in the unlikely event that both FETs fail or loss of DC power to the LNA. A block schematic of the signal flow within the MHA is shown in Figure 2 The MHA Low Noise Amplifier is supplied with +12.25V DC from the BTS RF feeder cable. This is achieved by using Bias Tee power injection at both the MHA and the BTS feeder cable interfaces. The Bias Tee assembly has a low RF loss while providing DC injection/tap-off for the LNA power feed. The unit also provides protection against the transient effects that may be induced by lightning strikes to any part of the tower. The overall system of 6 MHAs is supplied from a Power Distribution Unit (PDU) which provides 6 separate +12.25V outputs via a multi-way cable assembly to the Bias Tee. Each PDU output has a current detection window to monitor the LNA operation. Should the MHA current fall outside the pre-set normal operating current window, the PDU alarm will be activated. The PDU has individual indicators for each MHA alarm with an overall summary output alarm being provided to the BTS supervisory system. Each output and alarm detection circuit can be separately switched for MHA muting. The PDU operates from a -48V DC supply input from within the BTS support cabinet. The
-48V DC is converted to +12V DC for the MHA's using a dc-dc converter. A variety of interconnecting cable kits can be provided to enable the flexible installation of the PDU and to interconnect with the Bias Tee assemblies. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 7 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 ANT port Rx Rx Bias Tee BTS port Tx DC Figure 2 Masthead Amplifier Circuit Schematic LNA and bypass switch REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 8 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.1.2 Interfaces 1.1.2.1 Masthead Amplifier The MHA is provided with the following electrical interfaces (refer to Figure 3):
a) 7/16 Female (BTS): This is the connection for the duplexed Tx/Rx signals to/from the BTS. In addition to providing for RF transmission, this connector provides for DC feed via the RF cable and Bias Tee assembly. b) 7/16 Female (ANT): This is the connection for the Tx/Rx Antenna. This port should be as close as possible to the antenna with the connection being made with the shortest/lowest loss interconnecting cable practicable. c) M8 Earth Stud: This provides the Primary Lightning protection earth for the MHA. The earth cable should be of the largest cross sectional area and shortest length practicable and should be connected to a suitable earth point on the mast structure. M8 EARTH STUD 7/16 FEMALE (BTS) 7/16 FEMALE (ANT) Figure 3 Masthead Amplifier Interfaces REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 9 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.1.2.2 Power Distribution Unit Note:
The PDU is not required where DC power to the MHAs and Alarm functions are provided directly from the BTS. In a standard system configuration, an indoor PDU is used. Details of the indoor PDU interfaces are given below. A brief description of the outdoor PDU interfaces is also included in this section. Indoor PDU The PDU is provided with the following electrical interfaces (refer to Figure 4):
a) DC power input connector type SLA 4/90 3.2 SN: This connector is provided for the primary -48V DC input from the BTS supply and is wired as follows:
Pin Number Function 1 2 3 4 No Connection Equipment Ground Primary supply return
-48V Primary Supply Feed b) +12V DC Output connector type 'DB9S' 9 pole Female: This connector provides the 6 individually switched DC outputs to the Bias Tee for onward coaxial supply to the MHA and is wired as follows:
Pin Number Function 1 2 3 4 5 6 7 8 9 MHA No. 1 +12V DC Supply Output MHA No. 2 +12V DC Supply Output MHA No. 3 +12V DC Supply Output MHA No. 4 +12V DC Supply Output MHA No. 5 +12V DC Supply Output MHA No. 6 +12V DC Supply Output 0v DC return 0v DC return No connection REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 10 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 c) Alarm Output connector type 'DB9P' 9 pole Male: This connector provides the Sector and DC>DC Alarm Output and is wired as follows:
Pin Number Function 1 2 3 4 5 6 7 8 9 Sector 1 Alarm. Sector 2 Alarm. Sector 3 Alarm. DC - DC Alarm. 0V Ground. Sector 1 Alarm. Sector 2 Alarm. Sector 3 Alarm. DC - DC Alarm. d) M6 Earth Stud. Provides the Primary Lightning protection earth to the PDU. The earth cable should be of the largest cross sectional area and of minimum length practicable to provide maximum lightning protection. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 11 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Figure 4 Power Distribution Unit Interfaces (Indoor) REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 12 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Outdoor PDU The indoor compact PDU in housed inside a weatherproof enclosure to provide an Outdoor PDU. Additional lightning protection is included within the enclosure. Details of the outdoor PDU interfaces are shown in Figure 5 Figure 5 Power Distribution Unit Interfaces (Outdoor) REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 13 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Outdoor PDU is provided with the following electrical interfaces:
a) DC power input connector type SLA 4/90 3.2 SN: This connector in on the compact PDU unit inside the outdoor enclosure and is provided for the primary -48V DC input from the BTS supply. An input cable is passed through the grommet (DC input) on the enclosure panel and is wired as follows:
Pin Number Function 1 2 3 4 No Connection Equipment Ground Primary supply return
-48V Primary Supply Feed b) +12V DC Output connections to the Outdoor Bias Tees are provided using six cables with Binder connectors (one for each Bias Tee) shown in Figure 6. The cables are passed through six Bias Tee Feed grommets on the enclosure panel. PIN connections on the connector block inside the enclosure are as follows:
Number on Block Function 1(+,-) 2(+,-) 3(+,-) 4(+.-) 5(+,-) 6(+,-) MHA No. 1 +12V DC Supply Output and return MHA No. 2 +12V DC Supply Output and return MHA No. 3 +12V DC Supply Output and return MHA No. 4 +12V DC Supply Output and return MHA No. 5 +12V DC Supply Output and return MHA No. 6 +12V DC Supply Output and return c) BTS Alarm Output connector type '8 pin Metalok Bantam on the enclosure panel. This connector provides the Sector and DC>DC Alarm Output and is wired as follows:
Pin Number Function A and B C and D Summary Sector Alarm. DC DC Alarm Second 8 pin Metalok Bantam connector (EXT Alarm) in normally not used. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 14 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Figure 6 Bias Tee Cable Kit for Outdoor PDU 1.1.2.3 Bias Tee The Bias Tee is provided with the following electrical interfaces (refer to Figure 7):
a) DIN 7/16 Female (BTS): This is the connection for the duplexed Tx/Rx signals to/from the BTS. b) DIN 7/16 Male (ANT): This is the RF output connection to the Antenna feeder cable. As well as providing for RF transmission, this connector provides for DC feed via the RF cable to the MHA. c) PDU Input connector (type SMB Male for indoor Bias Tee, Binder for outdoor Bias Tee): This connector provides the DC supply input to the Bias Tee for onward supply to the MHA and it is wired as follows:
Pin Number Function Inner Outer Bias Tee +12V DC supply Input. Bias Tee DC return. d) M6 Earth Stud: Provides the Primary Lightning protection earth to the Bias Tee. The earth cable should be of the largest cross sectional area and of the minimum length practicable to provide maximum lightning protection. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 15 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Indoor Bias Tee Outdoor Bias Tee Figure 7 Bias Tee Interfaces Note: Alternative connector genders are available to suit cable interfaces. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 16 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.1.2.4 Cable Kit using indoor PDU and Bias Tees The cable kit comprises the necessary cables and interfaces to enable the interconnection of the PDU and Bias Tee units within the BTS cabinet. The relevant product code is N0500XXX (XXX depends on BTS type) for a BTS using quantity 6 off Bias Tees. a) PDU Output port to Bias Tee (refer to Figure 8) This cable comprises six individual screened coaxial cables with a 9 pole 90o free 'D'
type plug for connection to the PDU DC output socket. The six individual tails are terminated with an SMB free socket for attachment to each of the 6 Single Bias Tee DC inputs. Figure 8 PDU DC Output port to Bias Tee REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 17 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 b) PDU Alarm to BTS Alarm port (refer to Figure 9) This is an 8 conductor cable with a 9 pole 90o free 'D' type socket for connection to the PDU Alarm output socket. The other end is un-terminated to enable installer connection to the alarm concentrator PCB in the BTS cabinet. Figure 9 PDU Alarm port to BTS Alarm 1.1.2.5 MHA Mounting Kit The mounting kit comprises the brackets, fitted to both ends of the MHA, straps for pole mounted configuration and bolts for wall mounted configuration. There are two types of mounting bracket kits, Single-MHA mounting and Dual-MHA mounting as shown in Figure 10. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 18 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Single MHA Mounting Kit Dual MHA Mounting Kit Figure 10 Mounting Bracket Kits REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 19 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.2 Hardware Description 1.2.1 Masthead Amplifier The MHA comprises a tower top mounted enclosure which is provided with fixing suitable for wall or pole mounting. The enclosure is sealed to provide IP68 protection of the internal components. The MHA is based upon a triplexer filter design with an integrated Low Noise Amplifier and Bias Tee assembly. The whole internal module is formed from a single silver plated assembly to provide best in class insertion loss performance. The triplexer filters are arranged to provide a Low Loss transmit path by the use of a bandpass filter between the BTS and Antenna ports. Each of the external ports includes an internal diplexing junction to connect 2 off bandpass filters to the Tx filter. The Rx bandpass filter connected to the Antenna port provides pre-selection of Rx signals and protection from the high power transmitter signals. The Rx filter is connected to a Low Noise Amplifier with approximately 12dB gain. The LNA comprises a Quadrature coupled pair of GaAs FETs to improve IP3 high level performance and reliability. The LNA contains internal BITE detection circuitry to indicate failure of either FET and to signal a fault condition to the PDU within the BTS. In the unlikely event that both FETs fail, the bypass circuit switches the LNA out of line. The output of the LNA is then connected via a second Rx bandpass filter to the BTS port of the MHA. A Bias Tee assembly is fitted at the BTS port diplexer junction to enable a coaxial DC feed from the BTS to be fed off to the LNA. The Bias Tee assembly contains DC blocking in the RF path and RF blocking in the DC path. The unit has integral Lightning Protection to provide clamping of any lightning induced voltages which could damage the LNA circuitry. 1.2.2 Power Distribution Unit The MHA system is supplied with +12V DC from a Power Distribution Unit (PDU) which provides 6 separate outputs at to each MHA from an input supply of -48V DC (other options also available) derived from the BTS BBU. The conversion of the input at -48V to a +12V output voltage is achieved by a dc-dc converter system. The PDU supply input has transient and reverse power protection to prevent damage to the dc-dc assemblies. The outputs of the dc-dc assembly provide a supply to each of the +12V outputs. Each output has a front panel mounted Enable/Disable switch and a fuse for output protection. A current monitoring circuit is fitted in series with the supply to each output. This detects abnormal demand from the LNA and activates a summary alarm signal via a relay. The current detection circuit alarm can be enabled/disabled by a front panel mounted switch. Each alarm has its own indicator LED which confirms whether the MHA is OK (Green), Faulty (Red) or Disabled (Extinguished). All outputs have internal secondary transient protection against lightning. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 20 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 1.2.3 Bias Tee The Bias Tee consists of an integrated body housing a lightning protection and DC injection PCB and the RF ports for interconnection between the BTS and the MHA feeder cables. The unit is designed to fit on top of the BTS, fitting between the antenna feeder cable and the BTS output. The Bias Tee assembly contains DC blocking in the RF path and RF blocking in the DC path. The DC is fed from the PDU input and onto the coaxial cable to the Antenna/MHA to power the LNA. The Bias Tee has integral Lightning Protection using a Gas Discharge Tube and transorb to provide clamping of any lightning induced voltages which could damage the PDU. An input DC feed-through filter is incorporated to enhance the EMC performance. 1.2.4 Cable Kit The Bias Tee Kit includes 2 cables for:
DC (Octopus cable for indoor PDU, six separate for outdoor PDU) from PDU to the six Single-way Bias Tees Alarms from PDU to BTS All cables are plug to socket arrangements for module interconnection. 1.2.5 MHA Mounting Kit There are two types of MHA mounting brackets. The Single-MHA mounting bracket kit allows a single MHA to be mounted on either a pole or a flat surface. The Dual-MHA mounting bracket kit allows two stacked MHAs to be mounted on a pole or a flat surface. Pole mounting requires straps and flat surface mounting requires bolts. Two Single-MHA mounting bracket kits are required for two MHAs per sector system. Six kits are required for a three-sector site. One Dual-MHA mounting kit is required for two stacked MHAs per sector system. Three kits are required for a three-sector site. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 21 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2 Installation Manual 2.1 General CAUTION PRIOR TO INSTALLING THE MHA SYSTEM OR ANY OF ITS COMPONENTS, ENSURE THAT THE BTS TRANSMITTER OUTPUT IS TURNED OFF AND THAT PRECAUTIONS ARE TAKEN TO ENSURE THAT THE TRANSMITTER CANNOT BE ACTIVATED DURING THE EQUIPMENT INSTALLATION. Installation of REMEC-Airtech MHA adjacent to the antenna on a Base Station tower enhances the Rx path sensitivity and improves the general BTS performance. There is a detailed description of the technical performance of the REMEC-Airtech MHA in Section 2.4. Installation recommendations for a long and reliable life from the REMEC-Airtech MHA unit. is extremely straightforward and this manual is designed to give REMEC-Airtech recommend that the TERACOM (or equivalent) termination connectors be used for all RF feed lines and jumpers. The connectors are suitable for use with RF 50 Ohm cables of various diameters. (, 7/8, and 1 5/8 ). TERACOM part numbers are shown in the table in Section 2.1.1. REMEC-Airtech supply brackets for mounting the MHA to the tower. The brackets may be supplied already connected to the MHA so that the only action necessary is to fix the MHA to a suitable tower member or surface. If the brackets are not already attached, fit one to the top and one to the bottom of the MHA using bolts provided. The REMEC-Airtech G3 MHA can be mounted in any recommended orientation to provide maximum flexibility for the installer (see Figure 11). Ensure that the MHA is not installed where it may be used as a foothold. If the MHA is to be attached to a vertical round pole using the clamps provided in the kit, the pole should be between 75mm and 150 mm in diameter. The bracket system is also suitable for mounting the MHA to a vertical wall or similar surface using the bolts or screws through the holes already punched in the MHA brackets for this purpose. Mounting the MHA in a method not approved by REMEC-Airtech may invalidate the Warranty on the MHA unit. If in any doubt consult REMEC-Airtech on the following numbers:
REMEC-Airtech in Europe, Tel: +44(0)1296 319 319 Fax: +44(0)1296 319 200 REMEC-Airtech Inc., Dallas, USA Tel: (214) 443 9106 Fax: (214) 443 9487 REMEC-Airtech Far East, Malaysia, Tel: +603 795 1270 Fax: +603 795 1249 REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 22 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.1.1 Recommended RF Cable Installation Components Cable Reference Cable Type & Diameter Teracom Reference Cable Bracket Reference BTS to Tower Top RF 1 5/8"50 Ohm Tower Top to MHA
( Jumper ) MHA to Antenna
( Jumper ) RF 1/2"- 50 Ohm RF 1/2"- 50 Ohm 716f-F158-B 716f-F012-B 716m-F012-B 716f-F012-B N/A N/A N0400401 or N0400101 TERACOM is the trade mark of TERACOM Components AB, S-242 Hrby, Sweden 2.1.2 Installation Summary and Mounting Configuration This section gives a summary of installation instructions for an MHA configuration using a Single-MHA mounting bracket kit. Recommended mounting orientations are shown in Figure 11. Ensure that the MHAs are not installed where they may be used as a foothold. Same installation procedures and precautions must be adhered to when installing two MHAs using a Dual-MHA mounting bracket kit. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 23 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 SUMMARY INSTALLATION INSTRUCTIONS FOR REMEC-AIRTECH G3 MASTHEAD AMPLIFIERS REMEC-Airtech supply brackets for mounting the Masthead Amplifier (MHA) to the tower already fitted to the MHA so that the installation is as simple as possible. RF Jumpers should be diameter and as short as is practical. RF lines should not be bent through tight bends, and connectors should not be side-loaded. Consider this during siting of the MHA. Figure A GROUNDING STUD ANTENNA JUMPER CONNECTION Connect the MHA to the Grounding Bus-
bar using an adequate cable (Figure B).
(Max resistance to Ground 27 mW) REMEC-Airtech can supply a suitable copper cable of 35 mm2 cross section and 1.2 M long. Note: A lightning strike with inadequate Grounding may result in permanent damage to the MHA and will invalidate the Warranty. BASE STATION JUMPER CONNECTION Figure B The REMEC-Airtech G3 MHA is a fully sealed IP68 rated unit which may be mounted in any orientation. You should choose the most appropriate orientation to give the shortest and neatest cable runs for minimum loss. (Figure C) For pole mounting use the clamps provided in the kit. The pole diameter should be between 75mm and 150 mm. For more details please refer to the Installation Instructions or call REMEC-Airtech on:
Figure C
+44 (0)1296 319 319 ( Europe )
(214) 443 9106 ( USA )
+603 795 1270 (Far East) REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 24 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Figure 11 G3 MHA - Typical Mounting Configuration REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 25 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.2 Installation of Masthead Amplifier (MHA) 2.2.1 General Mounting Instructions The hardware for the installation arrives at the Base Station (BTS) site in two separate parts:-
1) The REMEC-Airtech Mast Head Amplifier (MHA) complete with brackets. 2) The MHA Mounting Kit containing mounting bracket system, mounting straps, the necessary nuts and washers and, if ordered, the MHA Ground cable. Procedure Overview The installation procedure is made simple by the fact that the REMEC-Airtech G3 MHA is supplied with easy to fit mounting brackets. Simply remove the MHA from its packing material, fit the Single-MHA or Dual-MHA mounting brackets if not already fitted, and attach it to a pole using straps or any flat surface using bolts provided with the mounting kit. Then, connection is made from the BTS feed to the MHA BTS port using the BTS jumper cable. Finally the connection is made from the antenna connector to the ANT port on the MHA using the antenna jumper cable. Note: The recommended cable for jumpers is RF 50 Ohm cable (or equivalent) with TERACOM (or equivalent) connectors as listed in the table on Section 1.2 of this manual. Tools Required for Installation inch drive Sockets - 8mm, 10mm inch drive ratchet inch drive Torque wrench Detailed installation procedures are given in the next Section. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 26 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.2.2 Detailed MHA Installation Procedure The MHA can be mounted on a flat surface or on a pole as shown in . A single MHA mounting is shown in this diagram. Two MHAs stacked on top of each other can be similarly mounted on a flat surface or a pole using a Dual-MHA mounting bracket-kit. Dual MHA mounting is shown in Figure 12 Flat Surface and Pole Mounting of a Single MHA REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 27 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Figure 13 Flat Surface or Pole Mounting of Stacked Dual MHAs a) Open the MHA outer box and remove the MHA and the Mounting Kit REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 28 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 b) Prior to installing the MHA assembly ensure that there is sufficient space available for the mounting of the equipment to the mast pole or to the wall structure. This necessary clearance should include access for cable bend radius and termination of the feeder. The REMEC-Airtech G3 MHA is sealed to a full IP68 rating and may therefore be fitted in any orientation. This feature is of particular benefit as it allows for the shortest cable runs and, therefore, system losses as well as for neat installation practice including, if possible, hiding of the MHA where aesthetic considerations are key. The unit should not be mounted in positions where it may be used as a foothold for tower personnel as this can cause internal damage which may not be covered by the REMEC-Airtech Warranty. (See Figure 11, Section 2.1.2) c) The REMEC-Airtech G3 MHA is supplied with the mounting brackets. Fit the single-
MHA or dual-MHA mounting, as necessary, if not already fitted. The MHA/MHAs may be attached to an antenna pole by the use of the two adjustable strap assemblies which should be fitted to the upper and lower mounting brackets. Thread each of the straps through the two slots provided in the mounting brackets. Wrap the straps around the mounting pole and locate into the worm drive screw assembly as detailed in Figure 14. Stacked Dual MHAs are also similarly mounted on the pole. The two screw assemblies should then be adjusted using a 10 mm open ended spanner or socket assembly, ensuring that the torque applied to the screw does not exceed 2 Nm. d) If the MHA is to be mounted on a flat (vertical or horizontal) surface, then this can be achieved using M6 bolts of an appropriate length. The bolts are passed through the holes provided in the mounting bracket already attached to the unit. e) Connect the MHA earth stud to the antenna earthing arrangement using a cable of at least 24 mm2 cross-sectional area. Fit the Ground Cable to the brass M8 stud on the front of the MHA using the brass washer, lock-washer and nut which should first have been removed from the MHA stud, and route the ground cable downwards. Tighten the M8 nut to the correct torque. Fit the lower cable lug to a suitable diameter bolt grounding point on the mast. Ensure that the torque applied to the MHA grounding stud does not exceed 10 Nm. This torque setting must not be exceeded or damage may occur to the unit, which will not be covered by the REMEC-Airtech Warranty. This maximum torque setting is marked clearly on a yellow label attached to the mounting bracket adjacent to the Earth Stud. Note: If the Ground cable has not been ordered from REMEC-Airtech the installer should ensure that the overall resistance of the Ground path from the MHA stud to Ground does not exceed 1000 mW
. The REMEC-Airtech recommended cable has a cross-section of 35 mm2 and a length of 1.2m. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 29 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 f) Connect the antenna jumper cable from the output of the antenna to the port labelled ANT on the MHA. Ensure that the connectors are correctly mated then tighten each connector to 20 - 25Nm using a torque spanner. This maximum torque setting is marked clearly on yellow plastic rings which are positioned over each connector. While the connectors used in the REMEC-Airtech G3 MHA are of a unique stress-
protected design, severe abuse can lead to damage of the connectors which may not be covered by the REMEC-Airtech Warranty. Ensure that the bend radii of the cable is not placing sideways stress on the cable or connectors. g) Connect the BTS feeder cable to the BTS port of the MHA. Ensure that the cable is correctly mated and securely connected observing the same precautions as used for the ANT connector detailed above. Ensure that the bend radius of the cable is not placing sideways stress on the cable or connectors. h) Once all connections are terminated on to the MHA each of the cable entry points should be sealed using an approved weatherproofing tape (Denso or similar). Ensure that any excess cable is securely attached to the mast to prevent movement or vibration which could lead to long-term connector or cable damage. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 30 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 WORM DRIVE SCREW TENSION BAND MOUNTING BRACKET M8 EARTH POINT MAST 75 150mm Figure 14 Installation of the MHA using a Single-MHA Mounting Bracket kit. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 31 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 NOTE Dimensions in brackets are for G20xxx
(GSM900, DAMPS800) MHAs. All other dimensions are common PCN1800, PCS1900. DAMPS800 and GSM900 MHAs to 54.3
(67.2) 122 47.8 374 398 116 47
(60.2) 92
(120) 162 61.8 Figure 15 Interface Drawing of G3 MHAs REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 32 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.2.3 Installation of Bias Tee a) Ensure the BTS is turned off and all transmitters inhibited. b) Remove the antenna feeder cables from the existing antenna output connectors (on top of the BTS cabinet) ensuring that each cable assembly is identified with its mating location. Note: loosen the cable support clamps where necessary to provide sufficient movement of cables. c) Attach a Bias Tee assembly to each antenna output cable from the top of the BTS cabinet. Tighten each connector to 14 Nm using a torque spanner whilst ensuring a counter torque is applied to the connector body. d) Connect each Bias Tee earth point to the cabinet primary earth using a short length of 6 mm2 earth cable. This should be terminated in an M6 tag for connection to the Bias Tee assembly ensuring that the earth connection is tightened to not greater than 4 Nm. e) The external antenna feeder cables should be re-connected to the Bias Tees, ensuring that each antenna is connected to its original BTS output port. Tighten each connector to 14 Nm torque whilst ensuring a counter torque is applied to the connector body. Re-tighten the cable support clamps where necessary to secure the cables. 2.2.4 Installation of Power Distribution Unit Note: A PDU is not required where DC supplies to the MHAs and the Alarm functions are provided directly from the BTS. Instructions a), b), and c) below are for a rack-mountable PDU. Locate and secured the non-rack-mountable PDU in a convenient position inside BTS and follow instructions d) and e) to compete the installation. a) Locate a suitable position in the BTS 19 support cabinet for the installation of the PDU. Where possible leave a 1u (44mm) space between the rectifiers and the PDU. b) c) Insert four off M6 cage nut assemblies into the equipment mounting rails within the cabinet to accept the fixing positions of the PDU. Install the PDU into the cabinet using four off M6 x 12 fixing screws and the previously fitted cage nut assemblies. These fixing screws should be tightened to not greater than 6 Nm. d) Attach a 2.5mm2 earth cable between the cabinet earth and the front panel earth point of the PDU. This cable should be fitted with an M6 cable tag for attachment to the PDU. Ensure that the PDU earth bolt is tightened to not greater than 4 Nm. e) Ensure that the PDU circuit supply breaker is turned off at the supply distribution board. Connect the PDU supply cable from the supply to the DC input connector of the PDU. Ensure that the connector latch is securely mated. The DC supply cable may be supported by tie wrapping with cable ties to the cabinet mounting rails. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 33 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.2.5 Installation of Cables a) Ensure that the cable kit contains the following items:
Cable assembly Octopus to Bias Tee. Cable assembly PDU alarm to BTS Alarm. b) Connect the Bias Tee Octopussy cable assembly to the PDU DC output port. Connect each of the 6 DC tails to the Bias Tee assemblies, ensuring that the correct DC cables are terminated to the appropriate Bias Tee. c) Connect Alarm cable assembly to the PDU ALARM output port. Connect the fly-lead tails to the BTS alarm concentrator Terminal Block pins TBD (Customer Defined). d) Ensure that all cable assemblies are suitably routed and tidily secured to the cabinet structure using cable ties as required to prevent accidental damage. e) The equipment is now ready for functional testing. 2.3 Grounding Cables and Lightning Protection 2.3.1 Clamping of cables and correct Grounding All RF and Ground cables should be clamped from movement at suitable intervals along their full length. The clamping should be arranged so that the end connectors are not subjected to significant loading either in tension or compression or bending. The clamping should also prevent movement of the cables in high wind, which could eventually cause degradation of the performance of cables and connectors. 2.3.2 Ground Path Requirements The Ground/Earth cable connecting the MHA Ground/Earth stud to the bus-bar should be of 35mm2 section copper to minimise the resistance. Note: Tests indicate that a 10 mm2 copper is likely to fuse in the event of a severe lightning strike induced current (for example 25kA). The cable specified for REMEC-Airtech Ground/Earth cable may be up to 50 metres in length, at which point its resistance is calculated at 28 mW
. It is desirable to minimise the overall resistance from MHA to Reference Ground even if this requires a long Ground/Earth cable from the MHA to the bus-bar. 2.3.3 Grounding/Earthing of the MHA The MHA contains circuits which provide lightning protection against high voltages which may appear between signal or power lines and the metal case, including the outer parts of the connectors and the screens of the RF cables. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 34 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 To reduce these voltages when they occur, a Gas Discharge device within the MHA has to strike, and the resulting current has to flow to earth by as low an impedance path as can be made possible. A Schematic of the Lightning Protection Circuit is shown in Figure 16. 2.3.4 Schematic of Lightning Protection circuit. CIRCUIT SCHEMATIC TO THE DIPLEXER
(DC SHORT) AIRLINE DC BLOCKING CAP TO BTS l/4 DC OUTPUT Figure 16 A Schematic of a Lightning Protection Circuit 2.3.5 Basic Grounding/Earthing: Good Practice REMEC-Airtech has provided an Earth stud on your Masthead Amplifier ( MHA ) and can supply a high conductivity cable to assist in this action. However, the efficacy of the protection depends to a greater extent on the Grounding/Earthing arrangement of the rest of the system than upon the REMEC-Airtech supplied cable. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 35 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 It cannot be stated definitively which method of Grounding/Earthing must be used. However, the following points of good practice should be considered:
The structure of the mast, assuming it to be metal, should be bonded to Ground/Earth Reference Potential. All legs of the mast and the Ground/Earth point of the BTS should be bonded to this reference. The bonding should achieve a resistance of not more than 0.1 Ohm between any two members. The resistance between the Mast top where the MHA is Grounded/Earthed and the Ground/Earth Reference should be less than 1 Ohm. If this resistance value cannot be achieved, a longer length of the type of cable which REMEC-Airtech has specified may be used to run from the MHA Ground/Earth stud down to the Reference Earth. The maximum length of cable should be 50 metres and it should run closely alongside the RF co-axial cable which goes to the MHA. In this way the inductance loop area formed by (1) the RF cable screen and (2) the Ground/Earth cable, which might intercept the lightning field, is reduced. The co-axial RF cable and the Ground/Earth cable should run down the central vertical axis of the mast structure i.e. the Grounded/Earthed legs of the mast should form an equidistant assembly around the vulnerable cables. This arrangement reasonably simulates a Faraday screen to shield the cables. More information on Grounding and Lightning Strikes can be found in the Frequently Asked Questions Section of this manual. 2.4 Installation Measurements 2.4.1 A Method of measurement of Static Gain of the MHA A technique of measuring the Static Gain of the MHA to ensure correct function of the unit is given below. The technique relies upon transmitting a signal (at about 0dBm) within the Rx band, from the bottom of the feeder cable up through the un-powered MHA to one of the two Rx antennae within a sector, and receiving this signal through the other antenna in the same sector. This signal then returns to the BTS through the MHA and feeder RF cable and is measured at this termination in the BTS. With the MHA of the receiving antenna turned off, the LNA is in bypass mode and a base-
line signal level is then received. When this MHA is supplied with DC power, the level of this signal will increase due to the MHA amplifier gain by a value of nominally 12 dB (within the limits of 11 to 13 dB) and the DC current drawn by the unit should be within specification. The transmitting side and the receiving side are exchanged to check the other MHA in the sector. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 36 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 2.4.2 Effects of Cable Length on the Noise Figure The Total System Noise Figure of a Base Station / Antenna system without an MHA is, in dB:
Fsys = F2 + L1
(Eqn 1) where F2 = Base Station Noise Figure (assumed 6.5dB) and L1 = Antenna RF feeder cable loss (assumed 2dB). Hence the System Noise Figure is linearly increased as the RF feeder cable length increases. 2.4.3 The effects of introducing REMEC-Airtech G3 MHA If an MHA is introduced into the system, with an assumed Numerical Gain of 12dB, and a Noise Figure of 1.8dB, the overall System Noise figure is heavily dependent on the MHA Noise figure F1 (from Friis Law):
In Noise Factor terms Fsys = F1 +((F2 x L1) -1 )
(Eqn 2) G1 where F1 = MHA Noise Factor and G1 = MHA Gain F2 = BTS Noise Factor and the System Noise Figure Fsys(dB) = 10 Log10( Fsys )
(Eqn 3) or Fsys(dB) = 10 log10 (Eqn 2) It can be seen that as the value of L1 increases (i.e. a longer feed cable) the System Noise Figure without an MHA increases linearly with L1, (Eqn 1), but that this has a smaller effect on the System Noise Figure, Fsys with an MHA (Eqn 2) because it is a second order effect in Eqn 2. The Whole System Sensitivity is linearly dependent upon the System Noise Figure in both cases. The greater the Noise Figure, the worse the Sensitivity. Hence the MHA which reduces the Overall System Noise improves the Base Station Sensitivity, particularly systems with high feeder losses. In tabular form, showing the effect of increasing feeder cable losses is as follows:
REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 37 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 L1 Without REMEC-Airtech MHA With REMEC-Airtech MHA Improvement Cable Loss System Noise System
(dB) Figure Sensitivity (dBm) System Noise Figure System Sensitivity (dBm) 0 1 2 3 4 5 4.5 5.5 6.5 7.5 8.5 9.5
-108.5
-107.5
-106.5
-105.5
-104.5
-103.5 2.12 2.24 2.39 2.57 2.78 3.04
-110.87
-110.72
-110.68
-110.42
-110.20
-109.95 in Sensitivity
(dB) 2.37 3.22 4.18 4.92 5.70 6.45 Expected Typical Value of L1 .
2.4.4 The Effect of Auxiliary attenuator in the Rx path In order to meet the ETSI 11.21 requirements in the presence of strong interfering signals in the uplink with some type of BTSs, it may be necessary to insert an attenuator in the antenna line (feeder cable) between the MHAs BTS port and the Antenna port of the BTS. The procedure to calculate the value of the required attenuator in is given in the following section. 2.4.4.1 Establishing the Optimal Attenuator with No MHA fitted The addition of attenuator in the uplink Rx path can be used to adjust the total gain for optimal dynamic range at the BTS Receiver input. The attenuation should be adjusted to give a total path loss of 6 dB in the uplink (receive) path which should include the loss in the RF feeder line already in position in any particular installation. As this feeder loss will vary between different installations due to the length and type of the RF feeder cable, the loss should be measured and the best match of attenuator determined. The technique for establishing the best attenuator is to measure the open-circuit Return Loss of the antennae system from the BTS using a Network Analyser. This figure represents the loss from the BTS up to Antenna and back, and so is numerically twice the feeder loss. After the measured Return Loss has been divided by two, a figure of the order of 2dB should be found for the RF feeder loss. Subtracting this from the ideal 6dB total path loss gives the value of the required attenuator. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 38 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 After fitting the attenuator, the Return Loss match measured should then be 12dB, which is the ideal figure for optimal performance. 2.4.4.2 Establishing the Optimal Attenuator with REMEC-Airtech MHA fitted The addition of attenuators in the uplink Rx path can adjust the total gain for optimal dynamic range at the BTS Receiver input. For the assessment and setting of the ideal attenuator, the MHA should be powered off, so that it is in bypass mode. The attenuation should be adjusted to give a total path loss of 8dB, and this should include the loss in the RF feeder line already in position in any particular installation plus the additional 2dB though the MHA. As this feeder loss will vary between different installations due to the length and type of the RF feeder cable, the loss should be measured and the best match of attenuator determined. The technique for establishing the best attenuator value is to measure the open-circuit Return Loss of the antennae system from the BTS using a Network Analyser. This figure represents the loss from the BTS up through the MHA in bypass mode to Antenna and back, and so is numerically twice the feeder loss. After the measured Return Loss has been divided by two, a figure of the order of 4dB should be found for the total feeder loss. Subtracting this from the ideal 8dB total path loss gives the value of the optimal attenuator. After fitting the attenuator, the Return Loss match measured should then be 16dB, which is the ideal figure for optimal performance for a system that includes an MHA. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 39 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 3 Operation and Maintenance 3.1.1 Set-up and Test a) Ensure that the PDU supply and each alarm enable and output enable switch is set to the off position. b) Switch on the PDU circuit breaker at the Supply distribution board. Note: Should the circuit breaker trip do not attempt to reset. c) Check all installation wiring for correctness before proceeding. d) Switch ON the PDU power switch. Ensure that the power on lamp illuminates Green and that the two dc-dc converter healthy lamps illuminate Green. This indicates correct operation of the PDU and the two dc-dc converter assemblies. e) At the PDU switch on each of the alarm enable lines and ensure that its associated output indicator LED illuminates Red to indicate a low current alarm. f) Switch on each MHA output enable switches one at a time. DO NOT SWITCH ALL SWITCHES TOGETHER. Ensure that each output indicator LED changes from Red to Green as each output is enabled. Note: Should the indicator remain Red, refer to Section 3.1.2 for fault finding procedures. g) When all MHAs have been switched ON, all the output indicators should be illuminated Green. h) Contact the Network Management Centre and ensure that the BTS alarm reporting system indicates correct operation of the MHA system. This confirms correct operation of all MHAs and the PDU. i) The installation is ready for performance testing. 3.1.2 Fault Finding and Repair Procedures The instructions given in the followings sections should be followed to carry our preliminary checks to identify and rectify any faults for normal operation of the MHA. If the problem still continues, the integrity of the feeder and thus the DC continuity between the MHA should be checked using the REMEC Airtech Test Kit available as an optional accessory. The description of the Test kit and the test procedures are detailed in Section 3.1.3 of this document. 3.1.2.1 No indication on PDU When the PDU is switched on, the power ON and dc-dc converter LEDs will illuminate to show that each of these circuits is functioning satisfactorily. Should there not be a supply ON indication perform the following circuit tests:
REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 40 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 a) Ensure that the DC supply is available and that the PDU circuit breaker is switched on at the distribution board. b) Ensure that the power input connector is plugged into the PDU power connection. Using a multi-meter, ensure that -48V is available on pin 4 with respect to pin 3 of this connector. c) If the supply input is available at the connection to the PDU, the PDU supply input fuse should be checked. Note: This fuse will fail if an incorrect polarity is connected to the PDU supply input. d) e) If the fuse has failed ensure that the PDU supply is correct before refitting a replacement 1 Amp fuse (slow blow type). If either of the dc-dc converter healthy lamps is extinguished, the dc-dc converter assembly may be producing a voltage outside its normal operating range. Remove the two thumb screws from the front panel assembly to gain access to the dc-dc converter modules. Ensure that each assembly is pushed securely into its mating connector. Remove the fuse from the faulty assembly and ensure that the fuse is intact. If the fuse has failed, replace it with a 0.5 Amp fuse (slow blow type). Should the fuse fail again the dc-dc converter assembly is faulty and the PDU should be replaced. 3.1.2.2 No PDU indication on supply output indicators a) Each PDU 12V output and alarm can be disabled by the use of DIP switches on the front of the equipment. If any of the supply output indicators are not illuminated either Red or Green and remain Extinguished, the probable cause is the Alarm enable switch being set to the Disable position. When the Alarm switch is switched to the Enable position the LED indicator should illuminate Green or Red. b) c) If the Status LED fails to illuminate when the output enable switch has been set to enable the PDU is faulty and should be replaced. If all Output Indicators are Extinguished the probable cause of the failure is the lack of 12V supply. Check the PDU indications as detailed in Section 3.1.1. 3.1.2.3 PDU output status indicators illuminated red Each PDU output has current sensing to ensure that the MHA is operating within the correct current window. The Output Indicator will illuminate Green indicatiing that the MHA is operating within the normal operating current window specified in the MHA Product Description. The PDU has alarm indications for over/under current consumption by the MHA. The Output Indicator will illuminate Red indicating a failure. Should an output indicator illuminate Red, proceed as follows:
a) Ensure that the associated PDU output enable switch is switched Enable to provide power to the MHA. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 41 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 b) Remove the MHA output fuse associated with the faulty output and ensure that the fuse is intact. A fuse failure will result in zero current which will give a low current alarm. If fuse is found to be open circuit replace with a 0.5 Amp (quick blow type). c) Should the replacement fuse fail, the cause is probably due to a short circuit between the inner and outer connections of the MHA supply feed or a failure of the Bias Tee. All connections should be checked for a short between the inner and outer. d) e) f) If the fuse is intact and the LED remains illuminated Red, the cause will be that the MHA is drawing a current outside of the normal operating range. The MHA current can be ascertained by connecting a digital multi-meter set to the highest current range between the inner contact and the side contact of the MHA output fuse holder. The nominal operating current should be as specified in the MHA Product Description. The meter range can then be adjusted to display the operating current. If the current exceeds the Alarm condition current given in the MHA Product Description, the MHA is faulty and should be returned for replacement. If, however, the output current indicates 0mA there is an open circuit in the supply connection to the MHA. Possible causes are a damaged or open circuit cable or the disconnection of RF cable assemblies between the MHA and the Bias Tee. The power input connection to the Bias Tee should also be checked. g) The integrity of the connection to the Bias Tee can be monitored using a digital multi-
meter. This should be connected to the ANT connector at the Bias Tee assembly with the centre contact positive. The voltage available at this connector should be approximately 12.25 V. h) It should also be possible to measure +12.25V DC at the end of the power feed to the BTS port of the MHA. If 12.25 V is available at the end of the BTS feeder cable to the masthead amplifier with zero current flow and an alarm indication, the MHA assembly has failed open circuit and should be returned for replacement. 3.1.3 MHA to Ground Equipment DC circuit Test 3.1.3.1 Introduction The REMEC-Airtech Test Kit D has been designed to provide the MHA installation teams with a simple to operate confidence tool, which can be used to confirm the current drawn by a MHA, and that the DC circuit between the BTS/PDU and the MHA is complete. Test Kit D comprises of four modules (shown in Figure 17 - Product Code N0402901):
Monitor Box Variable Load Wide Ranging Mains AC to 12 V DC Power Supply (Mascot) Vehicle DC Adapter The procedure described below uses Test Kit D for MHAs with 75 to 140 mA normal operating current. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 42 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 VOLTMETER HIGH NORMAL LOW SUPPLY LOAD (mA) Figure 17 DC Circuit Test Kit D REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 43 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 3.1.3.2 Description The Monitor Box is of a compact handheld design and is provided with both a 7/16 RF connector and a protected SMB connector thus providing a flexiable facility for checking installations with or without a Bias Tee installed. The Monitor Box can also be connected to the BTS 12VDC supply providing a convenient method of checking the 12VDC output from the BTS. The Variable Load provides, during troubleshooting a convenient constant current source, which has the provision for setting the current load to indicate to the BTS (or PDU) high/low current alarm in addition to the normal current drawn by a serviceable MHA. The Wide Ranging Mains Power Supply (Mascot) converts the local AC mains to provide the monitor box with a constant 12VDC supply. Additionally the flexibility of the Test Kit has been maintained by having a device, which can be used globally. The Vehicle DC Adapter provides an alternative 12VDC source for use where there is no mains available. The following additional equipment is also required Digital Multimeter IEC Mains Cable 3.1.3.3 Test Kit D confidence test It is advisable to check the function of the test kit prior to carrying out any measurements. To achieve this follow flow chart 1 in Figure 19:
VARIABLE LOAD MONITOR EXTERNAL From BTS ac
+12V SMB SMB TEST CABLE BTS (or PDU) Figure 18 Test Kit Configuration during confidence test REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 44 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 START WITH THE TEST KIT CONFIGURED AS PER FIGURE 1. SELECT FROM BTS ON THE MONITOR BOX ON THE VARIABLE LOAD BOX, SELECT IN TURN:
LOW, NORMAL, HIGH ON THE MONITOR BOX, THE LAMP INDICATES :
RED, GREEN, YELLOW WERE THE INDICATIONS CORRECT NO IS THE BTS ALARM WINDOW 75 140 mA NO REPLACE THE TEST KIT WITH THE CORRECT ALARM WINDOW KIT YES 1. 2. FAULT IN BTS FAULTY TEST 2. REPLACE THE KIT 1. CLEAR BTS FAULT CORRECT THE BTS REPORTING STATUS YES DOES BTS STATUS =
LOAD STATES YES BTS & TEST KIT CORRECT END Figure 19 Flow Chart 1 ~ Test Kit D confidence test REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 45 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 3.1.3.4 Checking the operating current of the MHA. After having installed the complete antenna system including the MHA, the operating current of the MHA can be checked. The Test Kit also provides a facility to check the operating current during various points of the installation. 3.1.3.4.1 Checking the operating current when neither the Bias Tee nor BTS are present. With the Test Kit configured as in Figure 20, select the MHA supply to External. The lamp on the monitor box indicates GREEN if the operating current is satisfactory. If any other indication is displayed then follow the trouble shooting guide. To check the actual operating current connect a Digital Multimeter set to the 0.5 volt range, to the test points of the monitor box, record the reading on the Digital Multimeter. Millivolts displayed on the multimeter equate to milliamps. MHA FEEDER MONITOR EXTERNAL ac
+12V Figure 20 Operating Current Test for a System without Bias Tee or BTS REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 46 of 59 Cable G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 3.1.3.4.2 Checking the operating current when a Bias Tee is connected and the BTS is not present. With the Test Kit configured as in Figure 21, select the MHA supply to External. The lamp on the monitor box indicates GREEN if the operating current is satisfactory. If any other indication is displayed then follow the trouble shooting guide. To check the actual operating current connect a Digital Multimeter set to the 0.5 volt range, to the test points of the monitor box, record the reading on the Digital Multimeter. Millivolts displayed on the multimeter equate to milliamps. MHA FEEDER BIAS TEE System Cable MONITOR BOX EXTERNAL ac
+12V Figure 21 Operating Current Test for a System with a Bias Tee but without a BTS REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 47 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 3.1.3.4.3 Checking the operating current when a Bias Tee is connected and the BTS is present. With the Test Kit configured as in Figure 22, select the MHA supply to External. The lamp on the monitor box indicates GREEN if the operating current is satisfactory. If any other indication is displayed then follow the trouble shooting guide. To check the actual operating current then connect a Digital Multimeter set to the 0.5 volt range, to the test points of the monitor box, record the reading on the Digital Multimeter.. Millivolts displayed on the multimeter equate to milliamps. FEEDE R BIAS TEE System cable MONITOR BOX BTS MHA ac
+12V BTS Figure 22 Operating Current Test for a System with a Bias Tee and BTS connected REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 48 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 4 Variable Gain MHA Option REMEC Airtech Variable Gain MHAs provide either 7 to 22 dB (PCN 1800 and PCS 1900 MHAs) or 2 to 12 dB (GSM 900 MHAs) gain range. The system operation is similar to that of the Fixed Gain described in Section 1.1.1 of this document. The DC power is provided by a PDU located near the BTS. The Set and Forget gain of the MHA is set remotely using a ground level equipment. The system utilises Bias Tees to provide DC supply to the MHA and transmit serial data Antenna Line Protocol (ATP) between the ground level gain setting and monitoring equipment and the tower top MHA. In addition to the PDU and Bias Tees described in Section 1.1.1 for a site of six fixed gain MHAs, the Variable Gain MHA system requires the following to enable Gain setting and status monitoring:
Antenna Line Protocol Modem supplied by REMEC Airtech A suitable Laptop Personal Computer (PC) supplied by the customer A Compact Disc containing software for the PC supplied by REMEC Airtech to be installed in the Laptop PC An extra interconnecting cable supplied by REMEC Airtech This additional hardware and the Variable Gain MHA are described in the following sections. 4.1 Hardware Description 4.1.1 Variable Gain Masthead Amplifier This description of the supplied Variable Gain Masthead Amplifier is applicable to the following GSM 900, PCN 1800 and PCS 1900 products:
A GSM 900 MHA with a 2 dB to 12 dB gain range settable in 1 dB steps. A PCN 1800 MHA with a 7 dB to 22 dB gain range settable in 1 dB steps A PCS 1900 MHA with a 7 dB to 22 dB gain range settable in 1 dB steps The above Variable Gain G3 Masthead low noise amplifier provide adequate gain to the receive signal to improve system sensitivity and increase the receive coverage to match the transmit area. These products are variants of G3 MHA described in Section 1.2.1 of this document and use the same duplexing and filtering technology except for the Low Noise Amplifier tile. The MHA filter configuration is that of a triplexer. A Tx filter is diplexed at both ends to two Rx filters. A low noise amplifier (LNA) is placed between the two Rx filters in such a way that eliminates interconnecting cables and thus optimises noise figures. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 49 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 the DC supply fail The LNA block comprises a balanced amplifier configuration using GaAs FETs followed by a MMIC module. The LNA also incorporates a PIN diode bypass switch with very low insertion loss. This low insertion loss bypass link is switched in, should:-
a) or b) An integrated planar Low Pass Filter (LPF) is also positioned immediately behind the amplifier to filter the bandpass re-resonance out of band frequencies ensuring the overall system MHA filter rejection specifications are met up to 13 GHz. a fault is detected within the amplifier circuit itself . The MHA is housed in a weatherproofed enclosure rated to IP68. 7/16 RF connectors provide interface to both the ANT and BTS ports of the unit. This enables the MHA to be mounted in line with the ANT and BTS jumper cables. An earthing stud is mounted on one end next to the BTS connector for earthing the MHA to the mast. LNA ARCHITECTURE The LNA tile provides a system receive gain of 7 to 22 dB (or 2 to 12 dB) in 1 dB steps. It consists of a two stage amplifier section followed by a digital attenuator and a low pass filter. It also incorporate a bypass switch designed to provide a low insertion loss link in the receive path in the case of a FET failure, or if the second stage fails. The DC power is transmitted to the MHA unit via the RF feeder cable using Bias Tees to couple the DC power onto the RF cables. The LNA tile incorporates a BITE circuit to monitor the status of the FET and MMIC amplifier devices and report failure to the Personnel Computer (or the PDU) utilising a serial communications interface modulated onto the RF feeder cable. The 4-bit word selecting the receive gain is set from a PC and the Antenna Line Protocol Modem using the serial interface The interface drawings shown in Figure 3 and Figure 15 are applicable to the VGMHA. 4.1.2 Power Distribution Unit The VGMHA requires Power Distribution Unit described in Sections 1.1.2.2 and 1.2.2 to provide DC power, and alarm functions in case of VGMHA failure. 4.1.3 Bias Tee The Bias Tee required to provide DC power and transmit the serial data is described in sections 1.1.2.3 and 1.2.3 4.1.4 Cable Kit The cable kit required to connect the system is described in sections 1.1.2.4 and 1.2.4. Cables required to connect the Antenna Line Protocol (ALP) Modem to the Bias Tee and a Laptop PC to ALP Modem are supplied with the ALP modem kit. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 50 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 4.1.5 Mounting Kit The mounting kit required to install the VGMHA on a flat surface or a pole is described in sections 1.1.2.5 and 1.2.5 4.1.6 Antenna Line Protocol Modem Kit The Antenna Line Protocol Kit (Product Code N26001) consists of;
Antenna Line Protocol Modem External AC to 12 V DC power supply (Mascot included in DC Circuit Test Kit D Figure 17) A RS232 interface cable with 9 pin D connectors on both ends A coaxial cable with SMB connectors on both ends A Gain Setting program Compact Disk. Note: A suitable Laptop Personal Computer must be supplied by the customer. This must have at least Windows 98 operating system 4.1.6.1 Antenna Line Protocol Modem The Antenna Line Protocol (ALP) Modem provides the means of communicating to the Variable Gain Masthead Amplifier. The control of gain is accomplished by coded signal
(serial data) applied, together with DC power to the MHA BTS input via the RF feeder cable. The ALP Modem provides the modulator (demodulator) for the serial data signals, which are imposed upon the DC supply. The DC supply is applied to the ALP Modem from an external mains to 12 V DCsupply. The serial data gain control and monitoring signals are transmitted via an RS232 interface from a Laptop Computer to the ALP Modem. Alternative connection to Tower Top MHA. Direct connection to RF feeder. 12V DC and Serial Data Signal 7/16 Connection to Tower Top MHA Via Bias Tee in the RF feeder. 12V DC and Serial Data Signal SMB Male ANTENNA LINE PROTOCOL MODEM Modulates and Demodulates Data from a Laptop PC onto 12 Volt DC supply for the MHA 12 V 0.5V 0.5 A max. 2.1mm jack centre pin positive Figure 23 Antenna Line Protocol Modem 9 pin D plug RS 232 interface from Laptop PC REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 51 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 4.1.6.2 Auxiliary 12 Volts Supply The 12 Volt DC power supply is supplied with the ALP Modem kit. The 85 to 260 V AC input is converted to 12 V DC 0.5 V at 0.5 Amps maximum. This unit provides DC power to the Modem and to the tower top VG MHA. 4.1.6.3 Gain Setting Program Compact Disc A Compact Disc containing a software for a PC is provided with the kit. Follow the instructions provided with the Compact Disc to install the Antenna Line Protocol program in the Laptop PC. This program is used to provide two-way communication between the Tower Top VG MHA and the Modem/PC on the ground. 4.2 Installation of Variable Gain MHA The mechanical and electrical interfaces of the Variable Gain MHA are identical to that of the Fixed Gain MHA. Follow the detailed installation instructions given in Section 2 to install the Variable Gain MHA and connect it to the PDU via the Bias Tee. 4.3 Operation and Maintenance of Variable Gain MHA Once the VG MHA system has been installed, follow the instruction given in Section 3 and ensure that the MHA is operating satisfactorily and that no fault conditions are shown on the PDU. Ensure that the LEDs on the PDU show green for the MHAs switched ON using the output enable switches. Having established that the VG MHA system is operating satisfactorily, follow the instruction given in Section 4.3.1 below to adjust the gain of the MHA. 4.3.1 Gain Setting of the Variable Gain MHA The set-up for the gain setting of the MHA is shown in Figure 25. Disconnect the normal 12 V DC supply from the PDU to the MHA at the SMB terminal of the Bias Tee. Using the SMB to SMB cable supplied with the ALP Modem kit, connect the SMB terminal on the ALP Modem to the SMB DC terminal on the Bias Tee. Connect the 12 V auxiliary supply to the 2.1 mm Jack connector on the Modem. Connect the Laptop Personal Computer to the ALP 9 pin D connector using the RS232 interface cable provided with the APL Modem kit. Switch ON the auxiliary supply and the computer. The Antenna Line Protocol is used to provide a two way communication facility between the ground level equipment and the tower top Variable Gain MHA.:
Ground to tower top:- RF gain setting, bypass operation. Tower top to ground:- Status information and fault reporting. A MHA Management Terminal window is displayed on the Laptop PC as shown in Figure 24. The right side of the window is used to set the required gain or bypass option. The left side of the window reports the set gain, fault status and any DC power interrupts. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 52 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Once the gain is set, the ALP model should be removed for use on other VG MHAs. Disconnect the SMB to SMB cable at the Bias Tee and reconnect the output SMB from the PDU. This restores the DC power and to the VG MHA and any fault conditions will be displayed by the alarm LEDs on the PDU. The summary alarm will be transmitted to the BTS as for fixed gain MHAs. The above procedure may be used if further gain adjustment is necessary. Reduced RF performance soft fail RF fault hard fail Product in RF bypass mode Gain value returned from tower top Intermittent connection monitor (0-255) ALP Connection status Comm port setting Figure 24 MHA Management Terminal Window on Laptop PC Up/Down RF gain adjustment Gain value sent to tower top Force MHA into bypass mode Reset DC interrupt counter to zero REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 53 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 Variable Gain MHA Incorporating ALP modem and microprocessor control 12 V DC and ALP data Bias Tee RF Feeder ac
+12VDC Auxiliary 12Volt supply Antenna Line Protocol MODEM RS232 interface Laptop Personal Computer BTS PDU Normal connection to provide 12 V DC to MHA. Disconnect this and connect ALP system to adjust MHA Gain . Reconnect PDU once MHA Gain set Figure 25 MHA Gain Adjustment using ALP Modem and Laptop PC REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 54 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 5 Frequently Asked Questions 5.1 Lightning Protection Circuit General Background to Lightning Strikes. Equipment installed on outdoor mast top environments is generally more vulnerable to lightning strikes than surrounding ground base equipment. For this reason the MHA has built-in circuitry to protect against such strikes which might otherwise cause permanent damage to the system. How does the lightning strike get to the MHA ?
A lightning strike hitting the top of the mast will cause an enormous current to flow from the mast top down to ground - or the nearest 'ground' point. Along the way the current will take the path of least resistance before finding 'ground'. There are various types of couplings which can take place which can result in damage being caused to electronic equipment during this process. However, the major threat to the MHA unit is the result of these large currents travelling along the ground sheath of the RF cables connecting the BTS and ANT. The current on the ground sheath is transformed into a high voltage appearing on the inner conductor. This occurs as a result of a parameter known as 'transfer resistance effect' of the cable. It is this inner voltage and current which is potentially the most harmful to electronic equipment. What forms of protection does the MHA use?
The ANT port is designed to intrinsically provide excellent protection against lightning due to the construction of the internal coaxial filters. Since the antenna port feed is tapped directly onto each first stage filter resonator the unit offers a very low resistance path to ground at lightning frequencies (the frequency band of a typical lightning strike is 3KHz to 100KHz). The BTS port protection is slightly different. The diagram below shows the circuit schematic of the bias tee/lightning protection scheme used inside the mast head amplifier. Is there any maintenance required on an MHA?
The REMEC-Airtech MHA is a sealed-for-life unit and the only checking required is for mechanical integrity of the mounting and jumper connections to check for tightness. There is no scheduled maintenance for the internal components. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 55 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 CIRCUIT SCHEMATIC TO THE DIPLEXER
(DC SHORT) AIRLINE DC BLOCKING CAP TO BTS l/4 DC OUTPUT Two important devices known as a gas discharge tube and a transorb suppresser are used to short the dc line to the low noise amplifier (LNA) to ground. This circuit is designed to respond quickly to high voltage/current bursts preventing the destructive voltage levels from reaching the LNA. What level of lightning specification has the REMEC-Airtech MHA been designed to meet?
The REMEC-Airtech G3 MHA has been designed to handle test cases based on international standard IEC 1312-1 (Protection against Lightning Strike into Information Equipment on Buildings) with no damage to their functionality. The unit has been subjected to the following limits at an approved lightning test house and continued to function normally after a single strike simulation hit. Understanding the wave-form data:
The graph below illustrates how this wave-form data is interpreted. The 10 in 10/350m sec refers to the rise time of the pulse. This time is for the difference between the 90% and 10% limits as shown on the graph. Similarly, the 350m sec is the time taken for the wave-
form to reach 50% of its maximum limit. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 56 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 LIGHTNING WAVEFORM DIAGRAM. Peak Value kA 100%
90%
50%
10%
10 m Sec. Rise 350 m Sec. Fall Time Test 1 a) A 50kA current pulse of wave-form 10/350m sec is applied to the outer conductor of the antenna 'ANT' port. b) A 50kA current pulse of wave-form 10/350m sec is applied to the outer conductor of the base transceiver station 'BTS' port. Test 2 a) A 4kV voltage and 5kA current pulse of wave-form 10/350m sec is applied to the 'ANT'
port. b) A 4kV voltage and 2.5kA current pulse of wave-form 10/350m sec is applied to the 'BTS'
port. NOTE:
REMEC-Airtech can also provide as an option lightning protection to meet IEC 801-5, pulse shape 8/20 mSec at 20kAmps. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 57 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 5.2 Mounting and Maintenance Why do REMEC-Airtech recommend Teracom connector be used on jumpers?
The Teracom connectors have an integral o-ring seal to the outer of the jumper cable and therefore do not need additional protection in the form of conformal sealing tape over-
wrapped after connections have been made. This makes for a reliable installation. Some Network Operators and Installation teams do choose to fit additional protection, however, and in doing so no damage will be done to the MHA. Why can the MHA be mounted in any orientation?
The REMEC-Airtech G3 MHA is unique in that it is designed and packaged to a full IP68 rating. Both the MHA enclosure and the 7/16 connectors have been specially designed to be fully water submersible and therefore the unit does not rely on drain holes or other devices to protect the internal components. As a result the REMEC-Airtech MHA may be mounted in any orientation. No other competitive product has this form of protection and, while they have to be mounted in a certain way in order to minimise water and water vapour penetration, those other units cannot be guaranteed to remain serviceable in severe weather conditions. The REMEC-Airtech unit is virtually totally protected against the environment. Can the MHA be mounted horizontally?
The REMEC-Airtech MHA can be mounted in any orientation to suit the particular logistics of any site. Ensure that it is not mounted where it can be used as a foothold. See Figure 11 for recommended mounting configurations. Why is the MHA fitted up the mast?
The Rx signal received from the mobile unit is a very low level signal. There is additional loss of this signal in the feeder cable from the antenna down to the Base Station. As the signal level is diminished, the effect of the signal noise becomes a greater and greater proportion of the Receive signal, thereby limiting the sensitivity of the Base Station. By amplifying the signal as near to the antenna as practical, the effect of the feeder cable loss is minimised and the sensitivity of the Base Station is improved. REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 58 of 59 G3 MHA INSTALLATION AND OPERATING MANUAL 00/OSM/0002 ISSUE 1 May 2000 6 Glossary AC ALP ANT BBU BITE BTS DC DCS LED MHA PDU RF Rx BT TBD Tx Alternating Current Antenna Line Protocol Antenna Battery Backup Unit Built In Test Equipment Base Transceiver Station Direct Current Digital Communication System Light Emitting Diode Masthead Amplifier Power Distribution Unit Radio Frequency Receiver Bias Tee To Be Determined Transmitter REMEC-Airtech G3 Masthead Amplifier Installation and Operating Manual Page 59 of 59
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2002-04-08 | 869 ~ 894 | AMP - Amplifier | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2002-04-08
|
||||
1 | Applicant's complete, legal business name |
Powerwave Technologies, Inc.
|
||||
1 | FCC Registration Number (FRN) |
0006771059
|
||||
1 | Physical Address |
1801 East Saint Andrew Place
|
||||
1 |
Santa Ana, CA, California 92705
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
OGA
|
||||
1 | Equipment Product Code |
G20034A1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R****** B******
|
||||
1 | Title |
Sr. Quality Engineer
|
||||
1 | Telephone Number |
714-4********
|
||||
1 | Fax Number |
714-4********
|
||||
1 |
r******@pwav.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | AMP - Amplifier | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Cellular Band Repeater | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Grant Conditions The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Frequency stability is dependant on the repeated licensed unit. The power output is the maximum for single and two channel operation. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Nemko Dallas, Inc.
|
||||
1 | Name |
M******** C****
|
||||
1 | Telephone Number |
972-4********
|
||||
1 | Fax Number |
972-4********
|
||||
1 |
@******@.
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22.901(d) | 869 | 894 | 0.17 | Amp | F9W | ||||||||||||||||||||||||||||||||||
1 | 2 | 22.901(d) | 869 | 894 | 0.17 | Amp | DXW | ||||||||||||||||||||||||||||||||||
1 | 3 | 22H | 869 | 894 | 0.17 | Amp | F8W | ||||||||||||||||||||||||||||||||||
1 | 4 | 22H | 869 | 894 | 0.17 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 5 | 22.901(d) | 824 | 849 | 0.17 | Amp | F9W | ||||||||||||||||||||||||||||||||||
1 | 6 | 22.901(d) | 824 | 849 | 0.17 | Amp | DXW | ||||||||||||||||||||||||||||||||||
1 | 7 | 22H | 824 | 849 | 0.17 | Amp | F8W | ||||||||||||||||||||||||||||||||||
1 | 8 | 22H | 824 | 849 | 0.17 | Amp | F1D |