Integration Manual RMI6, V1.6 This document and its contents shall not be reproduced or transferred in any form without express prior permission. All rights reserved. Profoto AB 2018 Specifications are subject to change without prior notice. Contents Integration Manual ........................................................... 1 Contents ............................................................................ 3 Important user information ............................................... 6 NOTE ABOUT RF: ..................................................... 6 SAFETY PRECAUTIONS! ......................................... 6 Introduction ...................................................................... 7 General Description ...................................................... 7 System Diagram ........................................................... 7 Hardware description ....................................................... 8 Mechanical Characteristics .......................................... 8 Dimensions ............................................................... 8 Image ........................................................................ 8 Mechanical Drawing ................................................ 8 Electrical Characteristics .............................................. 9 Pinout ....................................................................... 9 Recommended Operating Conditions .......................... 9 Interface Description .................................................. 10 Connector type ....................................................... 10 UART Serial Interface ........................................... 10 Reset interface ............................................................ 11 RF characteristics ....................................................... 11 Channel list ............................................................. 11 Important Integration Notes ........................................... 12 Mechanical Integration ............................................... 12 Electrical Integration .................................................. 12 Antenna Integration .................................................... 13 Certification information ................................................ 13 CE (EU/EES) .............................................................. 14 FCC (USA) ................................................................. 14 FCC Compliance Statement (Part 15.19) ............... 14 Warning (Part 15.21) .............................................. 14 RF exposure limits ........... Fehler! Textmarke nicht definiert. Integrators responsibilities to comply with FCC and IC Regulations ........................................................ 15 IMPORTANT NOTE: ............................................ 16 End Product Labeling ............................................. 16 IC Compliance Statement (Canada) ....................... 16 Japan (ARIB) .............................................................. 18 Preface Thank you for choosing Profoto!
Thanks for showing us your confidence by investing in a Profoto Air Remote or Profoto Air Sync device. For more than three decades we have sought the perfect light. What pushes us is our conviction that we can offer even yet better tools for the most demanding photographers. Before our products are shipped we have them pass an extensive and strict testing program. We check that each individual product comply with specified performance, quality and safety. For this reason our flash equipment is widely used in rental studios in Paris, London, New York, and Tokyo and also the most rented flash all over the world. Some photographers can tell just from seeing a picture, if Profoto equipment has been used. Professional photographers around the world have come to value Profotos expertise in lighting and light-shaping. Our extensive range of Light Shaping Tools offers photographers unlimited possibilities for creating and adjusting their own light. Every single reflector and accessory creates its special light and the unique Profoto focusing system offers you the possibility to create your own light with only a few different reflectors. Enjoy your Profoto product!
Important user information NOTE ABOUT RF:
This equipment makes use of the radio spectrum and emits radio frequency energy. Proper care should be taken when the device is integrated in systems. Make sure that all specification within this document are followed, especially concerning operating temperature and supply voltage range. Make sure the device is operated according to local regulations. The frequency spectrum this device is using is shared with other users. Interference can not be ruled out. SAFETY PRECAUTIONS!
Do not attempt to operate the equipment before studying the instruction manual and the accompanying safety instructions, failure to do so may result in serious injuries. Make sure that Profoto Safety Instructions is always accompanied the equipment!
Profoto products are intended for professional use!
Do not place or use the equipment where it can be exposed to moisture, extreme electromagnetic fields or in areas with flammable gases or dust!
Do not expose the equipment to hasty temperature changes in humidity conditions as this could lead to water condensation in the unit. Equipment must only be serviced by authorized and competent service personnel!
Any modifications will break the modular certification and require the module to be re-certified. Introduction RMI6 is the base for the next generation of Profotos versatile modular communication platform. It is based on the communication in the 2.4GHz ISM- band and has impressive performance with a range of up to 300 meters. General Description The RMI6 module is powered by an 8-bit micro processor with a radio transceiver from Chipcon and features a complete feature set for wireless interaction with the Profoto Air range of professional studio equipment. The module has a 3V UART for interaction with a wide range of devices including computers and other microcontrollers. System Diagram Hardware description Mechanical Characteristics Dimensions 33,0 x 13,0 x 3,0 mm [Length, Width, Height]
Weight approx 10g Image Mechanical Drawing Electrical Characteristics Pinout PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 GND
+3V TEST_0 SYNC GND
+3V RESET TEST_2 TEST_3 TRIGG RMTE TTL SPI_DAI SPI_CS COM_RX COM_TX SPI_CLK SPI_DAO TEST_1
(radio)
(radio) in/output High true, output
(cpu)
(cpu) Low true Flash data Flash clock Mx, in/output in/output Px, in/output SPI interface. Data input SPI interface, chip select input (low true) Serial port, high idle, input Serial port, high idle, output SPI interface, clock input. SPI interface, data output LED output, low = Light Recommended Operating Conditions Parameter DC Supply Current Temperature Comment Min Max Unit 3.3 V 0.15 A
+55 C 2.7
-10 0 Humidity 90 %rel, n.c. Interface Description Connector type The interface to the host system is implemented as a 19 solder pads. Please make sure to follow the guidelines for footprint. UART Serial Interface The UART is using pins 1, 15 and 16. To connect to a RS232 line you must use a TTL converter (a dongle from B&B Electronics is recommended) from 3V to 12V. Serial characteristics: 38400. 8, N, 1 (no flow control) For a list of available commands see the RS Toolbox documentation. NOTE!
Connecting the module to a UART port without a line level converter may damage the module. Reset interface The following conditions will lead to a reset on the RMI6 module:
Power on reset Low voltage (Brown Out) detected from internal supervisory circuit Reset by Software External reset through reset pin Reset by watch dog RF characteristics Parameter Frequency range Frequency stability Output power EU/US Output power Asia Min Typ. Max 2404
-25 7.9 6.74 unit 2479 MHz kHz
+25 18.9 dBm dBm 7.03 18.7 8.11 Channel list Channel Frequency Unit 2403,999 MHz 1 2411,997 MHz 2 3 2416,996 MHz 2421,994 MHz 4 5 2426,993 MHz 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2446,988 MHz 2453,987 MHz 2479,314 MHz 2406,998 MHz 2414,996 MHz 2429,992 MHz 2432,992 MHz 2435,991 MHz MHz 2438,99 2441,99 MHz 2451,321 MHz 2456,653 MHz 2459,652 MHz 2462,318 MHz 2465,317 MHz 2468,316 MHz 2471,316 MHz Important Integration Notes RMI6 has been designed to allow for easy integration with a wide range of devices. There are some key factors you need to consider when integrating the module. Mechanical Integration The module needs at least 3 mm clearance in order to fit.. The module should arrive with a 4x4 mm Data Matrix label which holds the model number, serial number and firmware information. Electrical Integration The minimum connections needed for operation is:
PIN Function 1 2 8 9 12 15 GND
+VCC COM TX Reset TTL COM RX Comment Digital ground Radio power UART output Active low Active low UART input Antenna Integration The RMI6 module is available in one configuration with an integrated chip antenna. The antenna should not be modified in any way, doing so will void the approvals for the module. Certification information The module has successfully undergone testing according to EN 300 328 V2.1.1, FCC 47 CFR Part 15, IC RSS -
247 Issue 2. For end products using the RMI6 module (as the only radio module), the following applies:
CE (EU/EES) The RMI6 module is in conformity with the essential requirements and other relevant requirements of the Radio Equipment Directive (2014/53/EU). Please note that every end product using the RMI6 module will need to undergo EMC testing according to EN 301 489-17 V3.1.1 . For RF, conduced test results can be inherited from the RMI6 test report to the end product using RMI6. Limited EN 300 328 V2.1.1 testing for radiated spurious emission is necessary and the test must be repeated with the end product using the RMI6 module. FCC (USA) FCC Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Radio Frequency Exposure WARNING: The RMI6 device radiates radio frequency energy at a level below the United States FCC radio frequency exposure limits. Nevertheless, this device should be used in such a manner that the potential for human contact during normal operation is minimized. For hand held operation, this device has been tested and meets FCC RF exposure guidelines when the device is positioned a minimum of 1.0 cm from the body. For on camera mounted operation, this device has been tested and meets FCC RF exposure guidelines when the device is positioned a minimum of 2.0 cm from the head.and must not be co-located or operating in conjunction with any other antenna or transmitter. Integrators responsibilities to comply with FCC and IC Regulations The RMI6 Module has been certified for integration into products only by OEM integrators under the following conditions: 1. The antenna(s) must be installed such that a minimum separation distance of 2.0cm is maintained between the radiator (antenna) and all persons at all times. 2. The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter. As long as the two conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-
product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE:
In the event that these conditions cannot be met (for certain configurations or co-location with another transmitter), then the FCC and Industry Canada authorizations are no longer considered valid and the FCC ID and IC Certification Number cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC and Industry Canada authorization. End Product Labeling The RMI6 module is labeled with its own FCC and IC ID. If the FCC and IC ID:s is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a fysical label or eLabel referring to the enclosed module. In that case the end product must be labeled in a visible area with the following: Contains FCC ID: W4G-
RMI6 and IC: 8167A-RMI6 IC Compliance Statement (Canada) This Device complies with Industry Canada License-
exempt RSS standard(s). Operation is subject to the following two conditions:
1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. IC RF Exposure limits The RMI6 device complies with the IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. For hand held operation, this device has been tested and meets IC RF exposure limits when the device is positioned a minimum of 1.0 cm from the body. For on camera mounted operation, this device has been tested and meets IC RF exposure limits when the device is position a minimum of 2.0 cm from the head Limites dexposition RF IC Le dispositif RMI6 est conforme aux limites sur lexposition aux rayonnements IC RSS-102 dfinies pour un environnement non contrl. En mode manuel, ce dispositif a t test et respecte les limites dexposition IC RF lorsque ce dernier est plac au moins 1 cm du corps. Pour un fonctionnement sur camra, ce dispositif a t test et respecte les limites dexposition RF IC lorsque ce dernier est positionn au moins 2 cm de la tte Japan (ARIB) Japanese Radio Law and Japanese Telecommunications Business Law Compliance. This device is granted pursuant to the Japanese Radio Law () and the Japanese Telecommunications Business Law () This device should not be modified (otherwise the granted designation number will become invalid).