all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 |
|
User Manual rev | Users Manual | 375.18 KiB | October 03 2016 | |||
1 2 3 | Cover Letter(s) | November 03 2016 | ||||||
1 2 3 | Cover Letter(s) | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Cover Letter(s) | October 03 2016 / November 03 2016 | ||||||
1 2 3 | External Photos | October 03 2016 | ||||||
1 2 3 | ID Label/Location Info | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Internal Photos | October 03 2016 | ||||||
1 2 3 | Cover Letter(s) | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Report | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Setup Photos | October 03 2016 | ||||||
1 2 3 | RF Exposure Info | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Report | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Report | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Setup Photos | October 03 2016 | ||||||
1 2 3 | Test Report | October 03 2016 / November 03 2016 | ||||||
1 2 3 | Test Setup Photos | October 03 2016 |
1 2 3 | User Manual rev | Users Manual | 375.18 KiB | October 03 2016 |
QCASP242 Product nameLow-Energy WiFi Dual-Band 802.11a/b/g/n Document Conventions Text Conventions bold Bold type within paragraph text indicates commands, file names, directory names, paths, output, or returned values. Example: The DK_Client package will not function unless you use the wdreg_install batch file. italic Within commands, italics indicate a variable that the user must specify. Example: mem_alloc size_in_bytes Titles of manuals or other published documents are also set in italics. Courier The Courier font indicates output or display. Example:
Menu Error:Unable to allocate memory for transfer!
The Menu character tag is used for menu items. Example: Choose Edit > Copy.
[ ]
{ }
|
Within commands, items enclosed in square brackets are optional parameters or values that the user can choose to specify or omit. Within commands, items enclosed in braces are options from which the user must choose. Within commands, the vertical bar separates options. An ellipsis indicates a repetition of the preceding parameter. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940
>
The right angle bracket separates successive menu selections. Example: Start > Programs > DK > wdreg_install. Notices NOTE: This message denotes neutral or positive information that calls out important points to the text. A note provides information that may apply only in special cases. Introduction The Atheros 802.11n Adapter supports 802.11n. The card uses the Atheros Client Utility
(ACU) which is a user-mode utility designed to edit and add profiles for selected Atheros network interface adapters. System Requirements Laptop/ PC containing:
32-bit PCI Express Bus 32 MB memory or greater 300 MHz processor or higher Microsoft Windows 2000, Windows Millennium Edition, Windows 98 Second Edition, Windows XP, or Windows NT 4.0 (with Service Pack 6) Profile Management Configure the wireless network adapter (wireless card) from the Profile Management tab of the Atheros Client Utility. Add a profile Edit a profile Import a Profile Export a Profile Order profiles Switch to a different profile Remove a profile Connect to a Different The wireless network adapter works in either infrastructure mode (which uses an access point) or ad hoc mode (a group of stations participating in the wireless LAN). Network Create or Modify a Configuration Profile To add a new configuration profile, click New on the Profile Management tab. To modify a configuration profile, select the configuration from the Profile list and click the Modify button. The Profile Management dialog box displays the General tab. In profile management:
Edit the General tab. Edit the Security tab. Edit the Advanced tab. To configure a profile for ad hoc or access point (infrastructure) mode, edit the Network Type field on the Advanced tab. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Note that the ACU only allows the creation of 16 configuration profiles. After the creation of 16 profiles, clicking the New button displays an error message. Remove an old profile or modify an existing profile for a new use. Remove a Configuration Profile 1. Go to the Profile Management tab. 2. Select the profile to remove from the list of configuration profiles. 3. Click the Remove button. Auto Profile Selection Management Including a profile in the auto selection feature allows the wireless adapter to automatically select that profile from the list of profiles and use it to connect to the network. Including a profile in auto profile selection:
1. On the Profile Management tab, click the Order Profiles button. 2. The Auto Profile Selection Management window appears, with a list of all created profiles in the Available Profiles box. 3. Highlight the profiles to add to auto profile selection, then click Add. The profiles appear in the Auto Selected Profiles box. Ordering the auto selected profiles:
1. Highlight a profile in the Auto Selected Profiles box. 2. Click Move Up, Move Down, or Remove as appropriate. The first profile in the Auto Selected Profiles box has highest priority, and the last profile has lowest priority. 3. Click OK. 4. Check the Auto Select Profiles box. 5. Save the modified configuration file. When auto profile selection is enabled by checking Auto Select Profiles on the Profile Management tab, the adapter scans for an available network. The profile with the highest priority and the same SSID as one of the found networks is the one that is used to connect to the network. If the connection fails, the adapter tries the next highest priority profile that matches the SSID, and so on. With auto profile selection enabled, the wireless adapter scans for available networks. The highest priority profile with the same SSID as a found network is used to connect to the network. On a failed connection, the adapter tries with the next highest priority profile. Switching to a Different Configuration Profile 1. To switch to a different profile, go to the Profile Management tab. 2. Click on the profile name in the Profile List. 3. Click the Activate button. The Profile List provides icons that specify the operational state for that profile. The list also provides icons that specify the signal strength for that profile. Import and Export Profiles Importing a Profile 1. From the Profile Management tab, click the Import button. The Import Profile window appears. 2. Browse to the directory where the profile is located. 3. Highlight the profile name. 4. Click Open. The imported profile appears in the profiles list. Exporting a Profile 1. From the Profile Management tab, highlight the profile to export. 2. Click the Export button. The Export Profile window appears. 3. Browse to the directory to export the profile to. 4. Click Save. The profile is exported to the specified location. TCP/IP Configuration Configuring the TCP/IP Address for the network device:
1. After configuring the wireless network adapter properties, open the Control Panel and open Network and Dial-up Connections. 2. Find the Local Area Connection associated with the wireless network adapter. Right-
click that connection, and click Properties. 3. Select Internet Protocol (TCP/IP) and click Properties. 4. Click the radio button Use the following IP address, then enter an IP address and Subnet mask. Assigning an IP address and Subnet mask allows stations to operate in access point mode (infrastructure mode) or in ad hoc mode and to have Internet access. Default gateway and DNS server information is also required. IP configuration information
(DHCP to assign the IP address, gateway and DNS server IP addresses) is usually obtained from the corporate IT staff. 5. Click OK to finish. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 General Tab In the Atheros Client Utility, access the General tab by clicking New or Modify on the Profile Management tab. Edit the fields in the General tab to configure the configuration profile. Make sure to also edit the Security and Advanced tabs. Profile Name Identifies the configuration profile. This name must be unique. Profile names are not case sensitive. Client Name Identifies the client machine. Network Names (SSIDs) The IEEE 802.11 wireless network name. This field has a maximum limit of 32 characters. Configure up to three SSIDs (SSID1, SSID2, and SSID3). Advanced Tab In the Atheros Client Utility, access the Advanced tab by clicking New or Modify on the Profile Management tab, then clicking the Advanced tab in Profile Management. Edit the fields in the Advanced tab of Profile Management to configure the profile. Transmit Power Level Power Save Mode Selects the transmit power level in mW. Actual transmit power may be limited by hardware. Specify:
Maximum mode causes the access point to buffer incoming messages for the wireless adapter. The adapter periodically polls the access point to see if any messages are waiting. Normal uses maximum when retrieving a large number of packets, then switches back to power save mode after retrieving the packets. Off turns power saving off, thus powering up the wireless adapter continuously for a short message response time. Network Type Specifies the network as either infrastructure or ad hoc. 802.11b Preamble Specifies the preamble setting in 802.11b. The default setting is Short &
Long (access point mode), which allows both short and long headers in the 802.11b frames. The adapter can only use short radio headers if the access point supports and uses them. Set to Long Only to override allowing short frames. Authentication Mode Select the mode the wireless adapter uses to authenticate to an AP:
Auto causes the adapter to attempt authentication using shared, but switches it to open authentication if shared fails. Open enables an adapter to attempt authentication regardless of its WEP settings. It will only associate with the access point if the WEP keys on both the adapter and the access point match. Shared only allows the adapter to associate with access points that have the same WEP key. For infrastructure (access point) networks, click the Preferred APs button to specify up to four access points to which the adapter should attempt to associate. Security Tab In the Atheros Client Utility, access the Security tab by clicking New or Modify on the Profile Management tab. Click the Security tab in the Profile Management window. Edit the fields in the Security tab of Profile Management to configure the profile. To define the security mode, select the radio button of the desired security mode. Make sure to also edit the General and Advanced tabs. WPA/WPA2 Enables the use of Wi-Fi Protected Access (WPA). Choosing WPA/WPA2 opens the WPA/WPA2 EAP drop-down menu. The options include:
EAP-FAST EAP-TLS EAP-TTLS PEAP (EAP-GTC) PEAP (EAP-MSCHAP V2) LEAP WPA/WPA2 Passphrase Enables WPA/WPA2 Passphrase security. Click on the Configure button and fill in the WPA/WPA2 Passphrase. 802.1x Enables 802.1x security. This option requires IT administration. Choosing 802.1x opens the 802.1x EAP type drop-down menu. The options include:
EAP-FAST EAP-TLS EAP-TTLS PEAP (EAP-GTC) PEAP (EAP-MSCHAP V2) LEAP If the access point that the wireless adapter is associating to has WEP set to Optional and the client has WEP enabled, make sure that Allow Association to Mixed Cells is checked on the Security Tab to allow association. Note: If the Lock checkbox is checked, you cannot change any values in this profile. See your system administrator. Pre-Shared Key
(Static WEP) Enables the use of pre-shared keys that are defined on both the access point and the station. To define pre-shared encryption keys, choose the Pre-Shared Key radio button and click the Configure button to fill in the Define Pre-
Shared Keys window. If the access point that the wireless adapter is associating to has WEP set to Optional and the client has WEP enabled, make sure that Allow Association to Mixed Cells is checked on the Security Tab to Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 allow association. None No security (not recommended). Using EAP-TLS Security To use EAP-TLS security In the Atheros Client Utility, access the Security tab in the Profile Management window. 1. On the Security tab, choose the WPA radio button. OR: On the Security tab, choose the 802.1x radio button. 2. Choose EAP-TLS from the drop-down menu. Enabling EAP-TLS security:
To use EAP-TLS security, the machine must already have the EAP-TLS certificates downloaded onto it. Check with the IT manager. 1. If EAP-TLS is supported, choose EAP-TLS from the drop-down menu on the right, then click the Configure button. 2. Select the appropriate certificate authority from the list. The server/domain name and the login name are filled in automatically from the certificate information. Click OK. 3. Click OK. 4. Activate the profile. Using EAP-TTLS Security To use EAP security In the Atheros Client Utility, access the Security tab in the Profile Management window. 1. On the Security tab, choose the WPA/WPA2 radio button. OR: On the Security tab, choose the 802.1x radio button. 2. Choose EAP-TTLS from the drop-down menu. Enabling EAP-TTLS security:
To use EAP-TTLS security, the machine must already have the EAP-TTLS certificates downloaded onto it. Check with the IT manager. 1. If EAP-TTLS is supported, choose EAP-TTLS from the drop-down menu on the right, then click the Configure button. 2. Select the appropriate certificate from the drop-down list and click OK. 3. Specify a user name for EAP authentication:
Check Use Windows User Name to use the Windows user name as the EAP user name. OR: Enter an EAP user name in the User Name field to use a separate user name and password and start the EAP authentication process. 4. Click Advanced and:
Leave the server name field blank for the client to accept a certificate from any server with a certificate signed by the authority listed in the Network Certificate Authority drop-down list. (recommended) Enter the domain name of the server from which the client will accept a certificate. Change the login name if needed. 5. Click OK. 6. Enable the profile. Using PEAP (EAP-GTC) Security To use PEAP (EAP-GTC) security In the Atheros Client Utility, access the Security tab in the Profile Management window. 1. On the Security tab, choose the WPA radio button. OR: On the Security tab, choose the 802.1x radio button. 2. Choose PEAP (EAP-GTC) from the drop-down menu. To use PEAP (EAP-GTC) security, the server must have WPA-PEAP certificates, and the server properties must already be set. Check with the IT manager. 1. Click the Configure button. 2. To avoid the need to log on again after resuming operation (for example, after your computer goes into standby or hibernate mode), check Always Resume the Secure Session. 3. Select the appropriate network certificate authority from the drop-down list. 4. Specify a user name for inner PEAP tunnel authentication:
Check Use Windows User Name to use the Windows user name as the PEAP user name. OR: Enter a PEAP user name in the User Name field to use a separate user name and start the PEAP authentication process. 5. Choose Token or Static Password, depending on the user database. Note that Token uses a hardware token device or the Secure Computing SofToken program (version 1.3 or later) to obtain and enter a one-time password during authentication. 6. Click Settings... and:
Leave the server name field blank for the client to accept a certificate from any server with a certificate signed by the authority listed in the Network Certificate Authority drop-down list. (recommended) Enter the domain name of the server from which the client will accept a certificate. The login name used for PEAP tunnel authentication fills in automatically as PEAP-xxxxxxxxxxxx, where xxxxxxxxxxxx is the computer's MAC address. Change the login name if needed. 7. Click OK. 8. Enable the profile. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Using PEAP-MSCHAP V2 Security To use PEAP-MSCHAP V2 security In the Atheros Client Utility, access the Security tab in the Profile Management window. 1. On the Security tab, choose the WPA radio button. OR: On the Security tab, choose the 802.1x radio button. 2. Choose PEAP (EAP-MSCHAP V2) from the drop-down menu. To use PEAP (EAP-MSCHAP V2) security, the server must have WPA-PEAP certificates, and the server properties must already be set. Check with the IT manager. 1. Click the Configure button. 2. Select the appropriate certificate from the drop-down list. 3. Specify a user name for inner PEAP tunnel authentication:
Check Use Windows User Name to use the Windows user name as the PEAP user name. OR: Enter a PEAP user name in the User Name field to use a separate user name and start the PEAP authentication process. 4. Click Advanced and:
Leave the server name field blank for the client to accept a certificate from any server with a certificate signed by the authority listed in the Network Certificate Authority drop-down list. (recommended) Enter the domain name of the server from which the client will accept a certificate. The login name used for PEAP tunnel authentication fills in automatically as PEAP-xxxxxxxxxxxx, where xxxxxxxxxxxx is the computer's MAC address. Change the login name if needed. 5. Click OK. 6. Enable the profile. Using LEAP Security To use security In the Atheros Client Utility, access the Security tab in the Profile Management window. LEAP security requires that all infrastructure devices (e.g. access points and servers) are configured for LEAP authentication. Check with the IT manager. Configuring LEAP On the Security tab, choose the WPA radio button. Choose WPA-LEAP from the drop-down menu. OR: On the Security tab, choose the 802.1x radio button. Choose LEAP from the drop-down menu. 1. Click the Configure button. 2. Specify a user name and password. Select to Use Temporary User Name and Password by choosing the radio button:
Check Use Windows User Name to use the Windows user name as the LEAP user name. OR: Check Manually Prompt for LEAP User Name and Password to manually login and start the LEAP authentication process. Select to Use Saved User Name and Password by choosing the radio button:
Specify the LEAP user name, password, and domain to save and use. 3. Enter the user name and password. 4. Confirm the password. 5. Specify a domain name:
Check the Include Windows Logon Domain with User Name setting to pass the Windows login domain and user name to the RADIUS server. (default) OR: Enter a specific domain name. 6. If desired, check No Network Connection Unless User Is Logged In to force the wireless adapter to disassociate after logging off. 7. Enter the LEAP authentication timeout time (between 30 and 500 seconds) to specify how long LEAP should wait before declaring authentication failed, and sending an error message. The default is 90 seconds. 8. Click OK. 9. Enable the profile. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Pre-Shared Encryption Keys Defining pre-shared encryption keys:
1. Click the Pre-Shared Key (Static WEP) radio button on the Security tab. 2. Click the Configure button. 3. Fill in the fields in the Define Pre-Shared Keys dialog box:
Key Entry Determines the entry method for an encryption key: hexadecimal (0-9, A-F), or ASCII text (all keyboard characters except spaces). Encryption Keys WEP Keys
(1-4) WEP Key Size Selects the default encryption keys used. Only allows the selection for a shared First, Second, Third, or Fourth key whose corresponding field has been completed. Defines a set of shared encryption keys for network configuration security. At least one Shared Key field must be populated to enable security using a shared key. Click on the radio button to set the key as the default encryption key. Defines the size for each encryption key. The options include:
64-bit (enter 10 digits for hexadecimal, 5 ASCII characters) 128-bit (enter 26 digits for hexadecimal, 13 digits for ASCII) 152-bit (enter 32 digits hexadecimal, 16 digits for ASCII) 4. Click OK for the changes to take effect. Overwriting an Existing Static WEP Key 1. Click the Pre-Shared Key radio button on the Security tab. 2. Click on Configure. 3. In the window, all existing static WEP keys are displayed as asterisks for security reasons. Click in the field of the existing static WEP key to overwrite. 4. Delete the asterisks in that field. 5. Enter a new key. 6. Make sure to select the Transmit Key button to the left of this key is selected for the key to transmit packets. 7. Click OK. Disabling Static WEP To disable static WEP for a particular profile, Select any other security option on the Profile Management tab to automatically disable static WEP OR: choose None on the Security tab to disable security, and click OK (not recommended). Using WPA Passphrase Security To use WPA Passphrase security In the Atheros Client Utility, access the Security tab in the Profile Management window. 1. On the Security tab, choose the WPA Passphrase radio button. 2. Click on the Configure button. 3. Fill in the WPA Passphrase. 4. Click OK. Zero Configuration This section describes the operation of the Atheros Client Utility (ACU) and Windows XP Wireless Configuration Service (WZCS). Wireless Network Configuration The Windows WZCS is a service that manages the wireless connection in a largely dynamic way. Only minimal connection information must be identified and configured. To set Zero Configuration on Windows XP, take the following steps:
1. 2. Select the check box Use Windows to configure my wireless network settings to set In Windows XP, open the Wireless Network Configuration Properties dialog box. Zero Configuration. When this check box is selected, Windows XP takes control of these settings for all configuration profiles:
SSID Security keys Ad hoc settings Note that Windows XP takes control of these settings for all configuration profiles, thus users can not ( create new profiles with different settings while using Windows Zero Configuration. The Zero Configuration settings override all configuration profiles, even when you select other options. However, the ACU does still control the following settings when Zero Configuration is set:
Power settings Active/Passive scanning (where applicable) Transmit power Wireless band Short/Long preamble (802.11b) Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 When Zero Configuration is in use, a pop-up message is displayed on the ACU when When Zero Configuration is in use, a pop up message is displayed on the ACU when you attempt to create or edit a configuration profile from the Profile Management tab of you attempt to create or edit a configuration profile from the Profile Management tab of you attempt to create or edit a configuration profile from the Profile Management tab of the ACU. To turn Zero Configuration off on Windows XP, take the following steps:
o Configuration off on Windows XP, take the following steps:
o Configuration off on Windows XP, take the following steps:
1. 2. Clear the check box In Windows XP, open the Wireless Network Configuration Properties dialog box. In Windows XP, open the Wireless Network Configuration Properties dialog box. In Windows XP, open the Wireless Network Configuration Properties dialog box. Clear the check box Use Windows to configure my wireless network settings Use Windows to configure my wireless network settings to set Zero Configuration. When this ch Zero Configuration. When this check box is cleared, all profile settings are controlled eck box is cleared, all profile settings are controlled by the configuration profile, which is set up from the ACU Profile Management tab. by the configuration profile, which is set up from the ACU Profile Management tab. by the configuration profile, which is set up from the ACU Profile Management tab. Check the Status Information or Diagnostics Check the Status Information or Diagnostics Check the Status Information or Diagnostics The Atheros client utility includes a number of tools to display current diagnostics and client utility includes a number of tools to display current diagnostics and client utility includes a number of tools to display current diagnostics and status information. Check current status Check current status Check driver information Check driver information Check receive and transmit diagnostics Check receive and transmit diagnostics Current Status The Current Status tab contains general information about The Current Status tab contains general information about the program and its the program and its operations. The Current Status tab does not require any configuration. The following operations. The Current Status tab does not require any configuration. The following operations. The Current Status tab does not require any configuration. The following table describes the items found on the Current Status screen. table describes the items found on the Current Status screen. Profile Name Link Status Wireless Mode IP Address Network Type The name of the current selected configuration profile. The name of the current selected configuration profile. Set up the configuration name on the General tab. Shows whether the station is associated to the wireless network. Shows whether the station is associated to the wireless network. Displays the wireless mode. Configure the wireless mode on the Configure the wireless mode on the Advanced tab. Displays the computer's IP address. The type of network the station is connected to. ation is connected to. Options include:
Infrastructure (access point) Ad Hoc Current Channel Configure the network type on the Advanced tab Advanced tab. Shows the currently connected channel. Shows whether server based authentication is used. Shows whether server based authentication is used. Server Based Server Based Authentication Data Encryption Displays the encryption type the driver is using. Displays the encryption type the driver is using. Configure the encryption type on the Security tab. Signal Strength Shows the strength of the signal. Click the Advanced button to see the advanced status diagnostics. Adapter Information Button The Adapter Information button contains general information about the network interface card (the wireless network adapter) and the network driver interface specification (NDIS) driver. Access the adapter information from the Diagnostics tab. Card Name Name of the wireless network adapter. MAC Address MAC address of the wireless network adapter. Driver Driver name and path of the wireless network adapter driver. Driver Version Version of the wireless network adapter driver. Driver Date Creation date of the wireless network adapter driver. Client Name Name of the client computer. Diagnostics Tab The ACU Diagnostics tab provides allows retrieval of receive and transmit statistics. The Diagnostics tab does not require any configuration. It lists these receive and transmit diagnostics for frames received by or transmitted by the wireless network adapter:
Multicast packets transmitted and received Broadcast packets transmitted and received Unicast packets transmitted and received Total bytes transmitted and received The Adapter Information button has general information about the wireless network adapter and NDIS driver. The Advanced Statistics button to shows statistics for diagnostics for frames received by or transmitted to the wireless network adapter:
Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Transmitted Frames Transmitted Frames Frames transmitted Frames transmitted OK Frames retried Frames dropped Frames dropped No ACK frames No ACK frames ACK frames RTS frames Clear-to-send (CTS) send (CTS) frames No CTS frames Retried RTS frames Retried RTS frames Retried data frames Retried data frames Received Frames Frames received OK Beacons Frames with errors CRC errors Encryption errors Duplicate frames AP mismatches Data rate mismatches Authentication time-out Authentication rejects: the number of AP authentication f AP authentication failures received by the wireless network adapter failures received by the wireless network adapter Association time-out Association rejects: the number of AP authentication rejects the number of AP authentication rejects received by the wireless network adapter received by the wireless network adapter Standard MIC OK Standard MIC errors CKIP MIC OK CKIP MIC errors Scan Available Networks Scan Available Networks Scan Available Networks Scan Available Networks Scan Available Networks Scan Available Networks Scan Available Networks Scan Available Networks Click the Scan button on the and ad hoc networks. On this list, click Refresh to refresh the list at any time. and ad hoc networks. On to refresh the list at any time. button on the Profile Management tab to scan for available infrastructure to scan for available infrastructure Connecting to a different network Connecting to a different network Highlight a network name and click the Highlight a network name and click the Activate button to connect an available connect an available network. If no configuration profile exists for that network, the Profile Management network. If no configuration profile exists for that network, the Profile network. If no configuration profile exists for that network, the Profile window opens to the General tab window opens to the General tab. Fill in the profile name and click Fill in the profile name and click OK to create the configuration profile configuration profile for that network. Infrastructure
(AP) Network Connected Infrastructure
(AP) Network Ad Hoc Network Connected Ad Hoc Network Encryption Active Qualcomm Atheros, Inc. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Display Settings To change the display settings, choose Options > Display Settings from the menu. The display settings dialog box contains tools to set the:
Signal Strength Display Units Sets the units used when displaying signal strength: percentage (%) or dBm. Refresh Interval Use the up/down arrows to set the display refresh interval in seconds. Data Display Sets the display to cumulative or relative:
Relative displays the change in statistical data since the last update. Cumulative displays statistical data collected since opening the profile. ACU Tools Use the Action menu to access the Atheros Client Utility tools:
Enable/Disable Radio Enable or disable the RF Signal on all Atheros Enable/Disable Tray Icon station reference designs. Enable or disable the tray icon. Troubleshooting Run the optional Troubleshooting Utility. Manual LEAP Login Log in to LEAP manually, if LEAP is set to manually prompt for user name and password on each login. Reauthenticate Reauthenticate to a LEAP-configured access point. Exit Exit the Atheros Client Utility application. Tray Icon The tray icon appears at the bottom of the screen, and shows the signal strength using The tray icon appears at the bottom of the screen, and shows the signal strength using The tray icon appears at the bottom of the screen, and shows the signal strength using colors and the received signal strength and the received signal strength indication (RSSI). Hold the mouse cursor over the tray icon to display the current configuration profile Hold the mouse cursor over the tray icon to display the current configuration profile Hold the mouse cursor over the tray icon to display the current configuration profile name and association, as wel name and association, as well as transmit and receive speed and the wireless adapter l as transmit and receive speed and the wireless adapter name and IP address. Right name and IP address. Right-click on the tray icon to:
Help Open the online help. Open Atheros Client Utility Troubleshooting Preferences Enable/Disable Radio Manual LEAP Login Reauthenticate Select Profile Show Connection Status Use the ACU to Launch the Atheros Client Utility (ACU). Use the ACU to configure a profile or view status and statistics information istics information. Run the Troubleshooting Utility. Set the ACU startup and menu options. Check to start the Set the ACU startup and menu options. Check to start the program automatically when Windows starts, and check ram automatically when Windows starts, and check menu items that should appear on the popup menu. menu items that should appear on the popup menu. Enable or disable the RF signal. Log in to LEAP manually, if LEAP is set to manually prompt manually, if LEAP is set to manually prompt for user name and password on each login. Reauthenticate to the access point. Click a configuration profile name to switch to. If no o. If no add a profile. configuration profile exists for a connection, add configuration profile name. auto profile selection is enabled. Shows whether auto profile selection This window displays connection information:
Active Profile Displays the active configuration profile Auto Profile Selection Connection Status Link Quality SSID Access Point Name Lists the quality of the link connection. of the link connection. Displays whether the adapter is connected to a Displays whether the adapter is connected to a wireless network. Shows the name of the AP the wireless adapter is Shows the name of the AP the wireless adapter is connected to. Displays the SSID of the associated network. Displays the SSID of the associated network. Access Point IP Address Link Speed Adapter IP Shows the IP address of the access point the Shows the IP address of the access point the wireless adapter is connected to. Lists the speed of the link connection. Lists the speed of the link connection. Displays the IP address of the wireless adapter. Displays the IP address of the wireless adapter. Qualcomm Atheros, Inc. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Address Exit Exit the Atheros Client Utility application. The colors are defined as follows:
Color Green Green Yellow Red Gray Quality Excellent Good Poor Poor RSSI*
20 dB +
10-20 dB +
5-10 dB
< 5 dB No Connection No Connection
*Received signal strength indication RSSI. Displayed in dB or percentage. Enable or disable the tray icon in the Action menu. Ad Hoc Mode In ad hoc mode, a wireless network adapter works within an independent basic service set (IBSS), as illustrated here. All stations communicate directly with other stations without using an access point (AP). To connect to an ad hoc network, configure the profile for ad hoc mode. Ad Hoc operation may be limited by Hardware to meet regulatory requirements. Ad Hoc Mode Profile Configuration To configure a profile in ad hoc mode, change the Network Type in the Profile Management's Advanced tab. For ad hoc mode, modify the settings:
Network Name (on General Tab) Transmit Power Level 802.11b Preamble (if using 802.11b) Wireless Mode When Starting an Ad Hoc Network Make sure to also edit the General and Security tabs. Infrastructure (Access Point) Mode In infrastructure (access point (AP)) mode, the wireless network adapter participates in a basic service set (BSS) as a station, and communicates with the other stations through an AP, as illustrated here. To connect to an access point network, configure the profile for access point mode. Infrastructure (Access Point) Mode Profile Configuration To configure a profile in infrastructure (access point) mode, change the Network Type in the Advanced tab. For access point mode, modify the settings:
Power Save Mode 802.11b Preamble (if using 802.11b) Wireless Mode 802.11 Authentication Mode Make sure to also edit the General and Security tabs. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Uninstall an Old Driver Uninstall an old driver before upgrading to a new NDIS driver release. To remove the newly installed driver from the system if the system does not have previously installed versions of the NDIS driver, proceed to Step 4. 1. To remove the NDIS driver from the OS, go to Device Manager, right-click Atheros AR500x Wireless Network Adapter, and choose Uninstall. 2. Click OK to uninstall the device. 3. When the device is uninstalled from Device Manager, search for and delete the driver files that reside in the system. a. Go to the Start menu and choose Search > For Files or Folders. b. Enter oem*.inf in the Search for files or folders named: field, and enter Atheros in the Containing text: field. c. Click Search Now. A few files matching these criteria are possible, if previous drivers have not been removed properly. d. Choose the files that have been found and delete them from the system. 4. To complete the uninstallation, remove the file ar5211.sys from the folder
\WINNT\system32\drivers. Additional Security Features These security features prevent attacks on a wireless network's WEP keys. The wireless adapter automatically supports each of these features, but these features must be enabled on the access point. Message Integrity Check (MIC) MIC prevents bit-flip attacks on encrypted packets. In a bit-flip attack, someone intercepts an encrypted message retransmits it after some alterations. Thus the receiver accepts the message as legitimate. The MIC adds some bytes to each packet to protect it against tampering. Temporal Key Integrity Protocol (TKIP) This feature prevents attacks on WEP in which someone catches encrypted packets and uses their initialization vector (IV) to decipher the WEP key. TKIP removes the predictability to protect both unicast and broadcast WEP keys. Broadcast Key Rotation EAP authentication provides dynamic unicast WEP keys for wireless adapters, but uses static broadcast keys. In broadcast WEP key rotation, the access point supplies a dynamic broadcast WEP key and changes it at intervals. Advanced Status Information Click the Advanced button on the Current Status tab of the Atheros Client Utility to see advanced information about the program and its operations. The Current Status tab does not require any configuration. The following table describes the items found on the Advanced Status screen. Network Name (SSID) Displays the wireless network name. Configure the network name on the General tab. Shows whether server based authentication is used. Server Based Authentication Data Encryption Displays the encryption type the driver is using. Configure the encryption type on the Security tab. Authentication Type Displays the authentication mode. Configure the authentication mode on the General tab. Message Integrity Check Shows whether MIC is enabled. MIC prevents bit-flip attacks on encrypted packets. Associated AP Name Displays the name of the access point the wireless adapter is associated to. Associated AP IP Address Associated AP MAC Address Shows the IP address of the access point the wireless adapter is associated to. Displays the MAC address of the access point the wireless adapter is associated to. Power Save Mode Shows the power save mode. Power management is disabled in ad hoc mode. Configure the power save mode on the Advanced tab. Current Power Level Displays the transmit power level rate in mW. Current Signal Strength Shows the current signal strength in dBm. Current Noise Level Displays the current noise level in dBm. Up Time Shows how long the client adapter has been receiving power (in hours:minutes:seconds). If the adapter runs for more than 24 hours, the display shows in days:hours:minutes:seconds. 802.11b Preamble Displays the 802.11b preamble format. Configure the preamble format on the Advanced tab. Current Receive Rate Shows the current receive rate in Mbps. Current Transmit Rate Displays the current transmit rate in Mbps. Channel Shows the currently connected channel. Frequency Displays frequency the station is using. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Channel Set Shows the current channel set. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
-
-
-
-
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: Contains FCC ID:
PPD-QCASP242. The grantee's FCC ID can be used only when all FCC compliance requirements are met. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the users manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Industry Canada statement:
This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme la norme CNR-247 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage prjudiciable, et (2) ce dispositif doit accepter tout brouillage reu, y compris un brouillage susceptible de provoquer un fonctionnement indsirable. Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Dclaration d'exposition aux radiations:
Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Dclaration d'exposition aux radiations:
Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. Cet appareil est conu uniquement pour les intgrateurs OEM dans les conditions suivantes:
1) L'antenne doit tre installe de telle sorte qu'une distance de 20 cm est respecte entre l'antenne et les utilisateurs, et 2) Le module metteur peut ne pas tre complant avec un autre metteur ou antenne. Tant que les 2 conditions ci-dessus sont remplies, des essais supplmentaires sur l'metteur ne seront pas ncessaires. Toutefois, l'intgrateur OEM est toujours responsable des essais sur son produit final pour toutes exigences de conformit supplmentaires requis pour ce module install. IMPORTANT NOTE:
In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the Canada authorization is no longer considered valid and the IC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate Canada authorization. NOTE IMPORTANTE:
Dans le cas o ces conditions ne peuvent tre satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre metteur), l'autorisation du Canada n'est plus considr comme valide et l'ID IC ne peut pas tre utilis sur le produit final. Dans ces circonstances, l'intgrateur OEM sera charg de rvaluer le produit final (y compris l'metteur) et l'obtention d'une autorisation distincte au Canada. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: Contains IC: 4104A-QCASP242. Plaque signaltique du produit final Ce module metteur est autoris uniquement pour une utilisation dans un dispositif o l'antenne peut tre installe de telle sorte qu'une distance de 20cm peut tre maintenue entre l'antenne et les utilisateurs. Le produit final doit tre tiquet dans un endroit visible avec l'inscription suivante: "Contient des IC: 4104A-QCASP242". Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the users manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 Manuel d'information l'utilisateur final L'intgrateur OEM doit tre conscient de ne pas fournir des informations l'utilisateur final quant la faon d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intgre ce module. Le manuel de l'utilisateur final doit inclure toutes les informations rglementaires requises et avertissements comme indiqu dans ce manuel. Caution :
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) the maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit;
(iii) the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate; and
(iv) the worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement set forth in Section 6.2.2(3) shall be clearly indicated.
(v) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement:
Le guide dutilisation des dispositifs pour rseaux locaux doit inclure des instructions prcises sur les restrictions susmentionnes, notamment :
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont rservs uniquement pour une utilisation lintrieur afin de rduire les risques de brouillage prjudiciable aux systmes de satellites mobiles utilisant les mmes canaux;
(ii) le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250 5 350 MHz et de 5470 5725 MHz doit tre conforme la limite de la p.i.r.e;
(iii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5 725 5 850 MHz) doit tre conforme la limite de la p.i.r.e. spcifie pour l'exploitation point point et lexploitation non point point, selon le cas;
(iv) les pires angles dinclinaison ncessaires pour rester conforme lexigence de la p.i.r.e. applicable au masque dlvation, et nonce la section 6.2.2 3), doivent tre clairement indiqus.
(v) De plus, les utilisateurs devraient aussi tre aviss que les utilisateurs de radars de haute puissance sont dsigns utilisateurs principaux (c.--d., quils ont la priorit) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. DETACHABLE ANTENNA USAGE This radio transmitter (IC: 4104A-QCASP242 / Model: QCASP242) has been approved by Industry Canada to operate with the antenna type listed below with maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le prsent metteur radio (IC: 4104A-QCASP242 / Model: QCASP242) a t approuv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. Transmitter Circuit Brand Model Ant. Type 2.4GHz Gain with cable loss
(dBi) Chain
(0)+(1) WNC 81-EBJ15.005 PIFA 3.62 5GHz Gain with cable loss
(dBi) 2.4GHz Cable Loss (dBi) 5G Cable Loss(dBi) Connector Type Cable Length
(mm) Band 1&2:
3.08 Band 3: 4.76 Band 4: 4.76 1.15 Band 1&2:
1.70 Band 3: 1.74 Band 4: 1.79 IPEX 300 Transmitter Circuit Brand Model Antenna Type 2.4G gain with cable loss (dBi) 5G gain with cable loss (dBi) Chain(0) QCA QCASP242-Ant PCB 1.72 1.91 2.4G cable loss
(dBi) NA 5G cable loss
(dBi) NA Connector Type Cable Length NA NA Qualcomm Atheros, Inc. 1700 Technology Drive, San Jose, CA 95110 t: 408/773-5200 f: 408/773-9940 5.25-5.35 1. 2. XXXyyyLPDzzzz-x
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-03-11 | JBP - Part 15 Class B Computing Device Peripheral | Original Equipment | |
2 | 5745 ~ 5825 | NII - Unlicensed National Information Infrastructure TX | ||
3 | 2472 ~ 2472 | DTS - Digital Transmission System |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2016-03-11
|
||||
1 2 3 | Applicant's complete, legal business name |
Qualcomm Atheros, Inc.
|
||||
1 2 3 | FCC Registration Number (FRN) |
0003716743
|
||||
1 2 3 | Physical Address |
1700 Technology Dr
|
||||
1 2 3 |
San Jose, California 95110
|
|||||
1 2 3 |
United States
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
L******@ul.com
|
||||
1 2 3 |
L******@ul.com
|
|||||
1 2 3 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
1 2 3 |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
|||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
PPD
|
||||
1 2 3 | Equipment Product Code |
QCASP242
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
P******** G******
|
||||
1 2 3 | Title |
Vice President, Regulatory Engineering
|
||||
1 2 3 | Telephone Number |
858-6********
|
||||
1 2 3 | Fax Number |
858-6********
|
||||
1 2 3 |
p******@qti.qualcomm.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 04/25/2016 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | JBP - Part 15 Class B Computing Device Peripheral | ||||
1 2 3 | NII - Unlicensed National Information Infrastructure TX | |||||
1 2 3 | DTS - Digital Transmission System | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Low-Energy WiFi Dual-Band 802.11a/b/g/n | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 | Modular Equipment Type | Single Modular Approval | ||||
1 2 3 | Purpose / Application is for | Original Equipment | ||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | Output power listed is maximum combined conducted. This device supports 20 and 40MHz channel bandwidths. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. This device supports client-only operating modes in the 5150-5350 MHz and 5470-5725 MHz bands. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. | ||||
1 2 3 | Output power listed is maximum combined conducted. This device supports 20 and 40MHz channel bandwidths for 2.4 GHz. This module may be installed only by the OEM or an OEM integrator. This transmitter has been approved for use in mobile RF exposure category configurations with the antenna(s) installed to provide a separation distance of at least 20 cm from all persons. The antennas used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Grantee must coordinate with OEM integrators to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission. | |||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch
|
||||
1 2 3 | Name |
E******** L****
|
||||
1 2 3 | Telephone Number |
+886-********
|
||||
1 2 3 | Fax Number |
+886-********
|
||||
1 2 3 |
e******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B | CC | ||||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15E | 38 CC | 5180 | 5240 | 0.014 | |||||||||||||||||||||||||||||||||||
2 | 2 | 15E | 38 CC | 5260 | 5320 | 0.014 | |||||||||||||||||||||||||||||||||||
2 | 3 | 15E | 38 CC | 5500 | 5720 | 0.014 | |||||||||||||||||||||||||||||||||||
2 | 4 | 15E | 38 CC | 5745 | 5825 | 0.014 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15C | CC | 2412 | 2462 | 0.192 | |||||||||||||||||||||||||||||||||||
3 | 2 | 15C | CC | 2467 | 2467 | 0.101 | |||||||||||||||||||||||||||||||||||
3 | 3 | 15C | CC | 2472 | 2472 | 0.0195 |