SU Pro, SU Air Outdoor Subscriber Radio Unit REFERENCE GUIDE Regulatory Compliance FCC/IC - Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and IC RSS standards. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. It is the responsibility of the installer to ensure that when using the outdoor antenna kits, only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden by FCC 47 CFR Part 15.204 and IC RSS standards. Warning Avertissement Caution Il est de la responsabilit de l'installateur de s'assurer que lorsque vous utilisez les kits d'antennes extrieures, seules les antennes certifis avec le produit sont utiliss. L'utilisation d'une antenne autre que ceux qui sont certifis avec le produit est expressment interdite par la rglementation FCC partie 47 CFR 15.204 et IC normes RSS. Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial liabilities. Resellers or distributors of this equipment are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. The installer should configure the output power level of antennas according to country regulations and antenna type. SU Pro, SU Air Reference Guide i Prudence Les units extrieures et les antennes doivent tre installs que par des professionnels expriments d'installation qui sont familiers avec les normes locales et les codes de scurit et, si applicable, sont agres par les autorits gouvernementales de rglementation comptents. Ne pas le faire peut annuler la garantie du produit et peuvent exposer l'utilisateur final ou le fournisseur de services financiers. Revendeurs ou distributeurs de ces quipements ne sont pas responsables des blessures, des dommages ou violation des rglements lis l'installation des units extrieures ou des antennes. L'installateur doit configurer le niveau de puissance de sortie des antennes conformment aux rglementations nationales et le type d'antenne. d'obligations juridiques et This equipment should be installed and operated with a minimum distance of 110 cm between the radiator and your body. Warning Cet quipement doit tre install et utilis une distance minimale de 110 cm entre le radiateur et votre corps. Avertissement The module is granted to operate under FCC Rules in the 2.4 / 4.9 / 5.4 /
5.8 GHz bands. Warning This device complies with Part 15 of the FCC rules and with Industry Canada license-
exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS (s). Son fonctionnement est soumis aux deux conditions suivantes:
1. Cet appareil ne peut pas causer d'interfrences, et 2. Cet appareil doit accepter toute interfrence, y compris les interfrences qui peuvent causer un mauvais fonctionnement de l'appareil. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada SU Pro, SU Air Reference Guide ii Overview The SU Pro, SU Air is an Outdoor Subscriber Radio Unit operating in the 4.9 5.8 GHz frequency bands. It is a TDD OFDM radio supporting 10 MHz, 20 MHz, 40 MHz and 80 MHz channel bandwidths. The 2.4 GHz WiFi interface supports standard 802.11/n HT-20, HT-40 operation modes. The SU Pro, SU Air supports cross polarized 2x2 MIMO antenna configuration for PtP and PtMP systems. The SU Pro, SU Air supports 2 RF connectors for interfacing external cross polarized 2x2 MIMO antenna. The SU Pro, SU Air also features an on-board WiFi 2.4 GHz interface module for short range control purposes. The SU Pro, SU Air is powered by a 24Vdc PoE device. The SU Pro, SU Air is certified with the FCC ID: Q3K-5XACULC-X and IC: 5100A-5XACULCX. Condition of Use The SU Pro, SU Air is a proprietary radio device and can only be deployed and maintained by RADWIN professional installers or its authorized subcontractors FCC rules and IC Regulation Restrictions The ODU firmware is factory programmed to operate under the FCC rules and Industry Canada regulation restrictions. The firmware is locked and inaccessible by any third party. As a result of the above the user interface allows both the installer and the user to control the ODU only within the boundaries of the regional restrictions. Antennas The SU Pro, SU Air is certified with a 17 dBi integrated flat crossed dual pole antenna type and with a 23 dBi external antenna, both covering Point-to-Point and Point-to-Multipoint operation configurations. SU Pro, SU Air Reference Guide 1 Certified Antenna Following are the antennas certified for use with the SU Pro, SU Air:
Antenna Type Manufacturer Model Number Frequency Range Antenna Max Gain (dBi) 4940-4990 14 Dual Pole Integrated RADWIN Ltd. MP0179180 Dual Pole External RADWIN Ltd. RW-9614-
5359 5150-5350 5470-5725 5725-5850 4940-4990 5150-5350 5470-5725 5725-5850 Omni RADWIN Ltd. On-Board 2400-2483.5 16 17 16 23 23 23 23 3 Maximum Output Power 5725 5850 MHz band - FCC/IC The maximum output power can be set as follows, when operating in the 5.8 GHz band, under FCC 47 CFR Part 15.407 New Rules and IC RSS-247 regulations. The power values are for PtP systems and PtMP systems. For PtMP systems the total EIRP is limited to 36 dBm. Therefore the output power of these systems will be reduced to comply with 36 dBm EIRP limit. The highest conducted output power shall be limited to 29 dBm in all channel bandwidths 4940 4990 MHz band - FCC/IC The maximum output power can be set as follows, when operating in the 4.9 GHz band, under FCC 47 CFR Part 90Y Rule and IC RSS-111 regulations. 10 MHz: 21.0 dBm 20 MHz: 21.0 dBm 5150 5250 MHz band FCC The maximum output power can be set as follows when transmitting in the 5.1 GHz band, under FCC 47 CFR Part 15.407 New Rules and regulations. The total EIRP limit for PtP applications is 45 dBm. The total EIRP limit for PtMP applications is 36 dBm. The total EIRP limit for PtMP applications when transmitting at elevations above 30 relative to the horizon is 21 dBm. 10 MHz: 26.0 dBm 20 MHz: 28.0 dBm 40 MHz: 28.0 dBm 80 MHz: 29.0 dBm SU Pro, SU Air Reference Guide 2 2400 2483.5 MHz band - FCC/IC The maximum output power can be set as follows, when operating in the 2.4 GHz band, under FCC 47 CFR Part 15.247 and IC RSS-247 regulations. The power values are for Wi-Fi systems for HT-20 and HT-40 Channel BW. The highest conducted output power shall be limited to 26 dBm in all channel bandwidths 5250 5350 MHz band FCC/IC The maximum output power can be set as follows, when operating in the 5.3 GHz band. The total EIRP limit is 30 dBm. 10 MHz: 11.0 dBm 20 MHz: 14.0 dBm 40 MHz: 14.0 dBm 80 MHz: 14.0 dBm 5470 5725 MHz band FCC/IC The maximum output power can be set as follows, when operating in the 5.4 GHz band. The total EIRP limit is 30 dBm. 10 MHz: 10.0 dBm 20 MHz: 13.0 dBm 40 MHz: 13.0 dBm 80 MHz: 13.0 dBm Channel Bandwidths and Frequency Range Channel BW
[MHz]
10 20 40 80 10 20 10 20 40 80 20 40 10 20 40 80 10 20 40 80 SU Pro, SU Air Reference Guide Center Freq. Range
[MHz]
5730 - 5845 5735 - 5840 5745 - 5830 5765 - 5810 4945 - 4985 4950 - 4980 5160 - 5245 5165 - 5240 5170 - 5230 5190 - 5210 2412 - 2462 2422 - 2452 5255 - 5340 5260 - 5340 5270 - 5330 5290 - 5310 5480 - 5715 5485 - 5710 5495 - 5700 5520 - 5680 3 Radio parameters accessed by end-user The following parameters can be accessed by user:
1. Output Power 2. Frequency channel 3. Channel bandwidth SU Pro, SU Air Reference Guide 4