Outdoor Door/Window Sensor L IN S TAL UI D E G Resolution Compatibles Outdoor Door/Window Sensor is a full-featured security transmitter with industry-leading wireless range and battery life. It is designed to sense the opening and closing of gates, sheds, and other outdoor open/close applications. An alarm signal will be transmitted when the magnet is pulled away from the sensor, or when an external contact is opened. Features Industry-leading wireless range and battery life Wide magnetic gap distance Two built-in external contact zones Secure encrypted wireless transmissions IP67 waterproof enclosure rating 5-year warranty Enroll by placing the panel into wireless enrollment mode and transmitting an enrollment signal from the sensor. Interlogix, Qolsys, DSC, and Cryptix sensors can be enrolled by pulling the battery tab or tampering the unit. Honeywell and 2GIG sensors can be enrolled by tripping the unit 3 times or holding the tamper and powering up the device by pulling the battery tab. Honeywell and 2GIG sensors must be enrolled as Loop 2 sensors. Alternatively, all sensors can be enrolled by manually entering the sensors serial number. Enrollment Signal Interlogix External 2 Power up the sensor while holding the tamper Honeywell & 2GIG External 1 & 2 Should be enrolled as Loop 1 and Loop 3, respectively. Enroll each external by tripping 3 times DSC Externals Trip desired external to enroll Mounting Screw Holes Magnet Alignment Marks Install by first attaching the mounting plate and magnet to a door, window, or fence using screws (provided) or cable ties
(not provided). Mounting Tips Face of mounting plate marked Flat Mount is to be mounted against flat surfaces (e.g. square wood post). Face of mounting plate marked Pole Mount is to be mounted against round surfaces (e.g. fence post). Cover-Securing Screw Hole Use the panel installation guide to verify proper system setup. I Make sure to align the alignment marks on the sensor and magnet when mounting. Finish by latching the sensor to the mounting plate and tightening the cover-securing screw to secure the sensor in place. Removal Tamper is implemented by screwing the provided screw with rubber washer through the removal tamper screw hole in the base and into the mounting surface. Remove the battery for access to the removal tamper screw hole. External Contacts can be installed by routing the wires through the back of the enclosure. A thinned area in the enclosure must be punched out with a screwdriver to allow the wires through. After routing and connecting the wires, reseal the hole with silicone Removal tamper screw hole Use normally-closed contacts because the sensor will transmit a signal when it sees an external contact open. Do not use End-of-Line Resistors. Wire the contact to one or both outside terminals using the center terminal as common. Thinned area for external contact wires Battery Reed Switch External 2 Common External 1 Pro Tips Metal installs should include pre-drilling holes before using screws to secure the mounting plate and magnet. Wireless performance is optimized when mounted near the top of the gate or door in a vertical orientation. Magnet Gap Specifications Non-Ferromagnetic Surface (e.g. Wood, Vinyl, etc.) Nominal Mounting Distance X Axis - Make Break Y Axis - Make Break Z Axis - Make Break 2.70 inches (6.86 cm) 2.80 inches (7.11 cm) 2.85 inches (7.24 cm) 3.50 inches (8.89 cm) 3.55 inches (9.02 cm) 3.27 inches (8.31 cm) 3.33 inches (8.46 cm) Ferromagnetic Surface (e.g. Iron, Nickle, etc.) Nominal Mounting Distance X Axis - Make Break Y Axis - Make Break Z Axis - Make Break 1.90 inches (4.83 cm) 2.00 inches (5.08 cm) 2.05 inches (5.21 cm) 2.50 inches (6.35 cm) 3.00 inches (7.62 cm) 2.32 inches (5.89 cm) 2.37 inches (6.02 cm) Y Axis X Axis Z Axis X Axis Specifications Physical Housing Dimensions Weight with Battery Mounting Fasteners Removal Tamper Fastener Environmental Operating Temperature Maximum Humidity Ingress Protection Rating Sensor Specifications Frequency Replacement Battery Nominal Battery Life Battery Voltage Current Draw Max Wire Length Transmitted Indications Certification 3.3 x 1.3 x 2.8 inches (8.4 x 3.3 x 7.1 cm) 5.7 ounces (161.6 grams) Four 1 inch stainless steel screws (provided) One 11/4 inch stainless steel screw with rubber washer (provided)
-40 to 158F ( -40 to 70C) 100% Relative Humidity (RH) IP67 433.92 MHz, 319.5MHz, 345MHz One Panasonic CR123A Lithium Battery 10 years 3.0 VDC (Nominal), 2.2 VDC (Low) 20 mA (Maximum), 0.6 uA (Quiescent) 7.5 feet Cover Tamper, Removal Tamper, Low Battery, Supervision RE107, RE207, RE207T, RE307 FCC, IC Specifications subject to change without notice WARRANTY Alula will replace non-portable products that are defective in their first five (5) years and all portable products in their first two (2) years. IC NOTICE This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux cnr dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) Lappareil ne doit pas produire de brouillage, et
(2) Lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. IC: 8310A-RE107, 8310A-RE207, 8310A-RE307 FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Alula could void the users authority to operate this equipment. FCC ID: U5X-RE107, U5X-RE207, U5X-RE307 TRADEMARKS ALULA IS A TRADEMARK OWNED BY ALULA HOLDINGS, LLC. INTERLOGIX, HONEYWELL, DSC, QOLSYS, AND 2GIG ARE TRADEMARKS OWNED BY UNITED TECHNOLOGIES ELECTRONIC CONTROLS INC., HONEYWELL INTERNATIONAL INC., TYCO SAFETY PRODUCTS CANADA LTD, QOLSYS INC. AND 2GIG, RESPECTIVELY. ALULA PRODUCTS WILL FUNCTION WITH ONE OF EITHER INTERLOGIX (FORMERLY GE), QOLSYS, HONEYWELL, DSC, OR 2GIG SYSTEMS. HOWEVER, NO ALULA PRODUCT IS PRODUCED BY, ENDORSED BY, NOR IS OFFICIALLY ASSOCIATED WITH INTERLOGIX (FORMERLY GE), QOLSYS, HONEYWELL, DSC OR 2GIG. ALULA RECOMMENDS VERIFYING PROPER ENROLLMENT AND OPERATION, PER CONTROL PANEL INSTALLATION INSTRUCTIONS, AT INSTALLATION. 47-0060-00 REV A 2018-11-07 Tech Support Line (888) 88-ALULA (888) 882-5852 alula.net 01