MIRACO 3D SCANNER Quick Start Guide V1.0 With the update of MIRACO software functions, the Quick Start Guide will be correspondingly updated. Please scan the QR code and visit the official MIRACO support page to download the latest version. www.revopoint3d.com/pages/
support-miraco Contents About MIRACO Whats in the Box?
First Use Unboxing and Setup Helpful Screen Gestures Scan Model Edit Software Update Skills Using Single Shot Mode Using Marker Mode File Transfers Via USB Cable Connecting to an External Screen 0 1 02 03 03 05 06 08 09 1 0 1 0 1 1 1 2 1 3 MIRACO Quick Start Guide About MIRACO MIRACO is a versatile, all-in-one 3D scanner designed for professionals. Featuring a robust quad-depth camera system, it offers accuracy ranging from ultra-fine detail capture with a single-frame accuracy up to 0.05 mm to broader area scans with still remarkable accuracy. Its high-resolution RGB camera also ensures stunningly realistic color scans, making it a powerful tool for a wide range of 3D scanning applications. Product Name3D ScannerModelMIRACOInput7-11V/5A Projector White Flash LED 2 RGB Camera Far-mode Depth Camera 2 Near-mode Depth Camera 2 Speaker MIRACO D SCANNER USB Type-C Port Anti-slip Pad Infrared Fill Light 8 Start/Pause Scan Button Power Button AMOLED Screen Ergonomic Grip Air Vents 1/4" Threaded Hole C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 01 MIRACO Quick Start Guide Whats in the Box?
MIRACO 3D Scanner USB Type-C to C Cable 65W Dual USB Type-C Port
(1.8 m) Power Adapter Turntable Topper Mini Turntable Turntable USB Cable MIRACO Near-mode Calibration Board Scanner Bag Wrist Strap Tripod Markers, Magic Mat 2 Sample Bust Cleaning Cloth 1 Note:
Quick Start Guide Certificate & Warranty Card 1. The MIRACO Pro (32 GB RAM) package also includes the Far-mode Calibration Board 4, Large Calibration-board Sheet 1 and a USB Type-C to HDMI Adapter. 2. The Power Adapter may vary depending on the country or region. 02 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED MIRACO Quick Start Guide First Use Unboxing and Setup Step 1: For the first use, please charge the MIRACO to more than 60%. 1 0 0
Step 2: Long-press the Power Button (5s) to turn on. Power Button C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 03 MIRACO D SCANNER MIRACO Quick Start Guide Step 3: Select a language. Start Step 4: Connect to a Wi-Fi network for project transfers and software update notifications. Wi-Fi Step 5: Adjust and confirm the Date and Time. Step 6: Tap Next to enter the Scan Interface, and functions on this page display as below:
1 Auto WB Auto 04 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED
Continuous Model Select Wi-FiBackNextEnglishEnglishDeutsch...RevopointExcellentGoodFarNear MIRACO Quick Start Guide Depth Display Window RGB Display Window Distance Display Far & Near Mode Switching 3D Display Window Base Removal / Scanning Distance / Color Display / 3D Coordinates Continuous & Single-shot Switch Scan Settings Scan Control Buttons Model Hub Helpful Screen Gestures 1. Swipe down from the top of the screen to display the Quick Settings menu. 45%
Storage WLAN Screen Rotation Settings Screenshot Screen Recording Shut Down 2. Screen Gestures for the Home or Post-processing page are as below:
One-finger Swipe:
Rotates the model on the screen. Two-finger Drag:
Moves the model. Pinch to Zoom:
One-finger Drag:
Together to zoom out; apart to zoom in. Model selection. C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 05 MIRACO Quick Start Guide Scan Step 1: Instructions. Read the instructions for [Scan Settings] and [Exposure Adjustment] on MIRACO when it is first activated. Step 2: Set up a scanning environment. For the first scan, it is recommended to scan the Sample Bust included in the package. Find a tabletop free of any clutter, put the Sample Bust on the turntable, and ensure no unwanted objects are within the scanning area. Near-mode Distance:
about 18 cm Step 3: Select a scanning mode. Selecting [Continuous] and [Near] modes to scan the Sample Bust is recommended. 1 Auto WB Auto Near Continuous Model 06 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED Far Near?ExcellentGoodFar MIRACO Quick Start Guide Step 4: Scan settings before scanning. 1) Scan Settings The recommended scan settings for Sample Bust are [High Accuracy], [Feature], [General], untoggled [Color].
Continuous Scan Settings OK Accuracy High Standard High-speed (16 fps) Alignment Feature Marker Object Type General Dark Color Model 2) Its also recommended to [Base Revomal Off]. 1 Auto WB Auto
Continuous Base Removal Off Model 3) Depth Cameras exposure Adjustment It is recommended to disable [Auto] exposure for the Depth Cameras and manually adjust the exposure bar until there are minimal red or blue areas in the preview. 2 1 6 Auto Auto Auto Correct Exposure Underexposed Overexposed C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 07 ExcellentGoodFarNearExcellentGoodFar MIRACO Quick Start Guide 4) Scan Distance Adjustment Move MIRACO to adjust the distance between the scanner and the target object, ensuring the scanning distance indicator bar displays green. 100%
Auto
Continuous Continuous Tap the button to Start, and tap it again to pause your scan as needed. Step 5: Start scanning. Step 6: Complete scanning. Model Tap the [Complete] button to finish the scan when all data is captured. Model Model Edit Step 1: After completing the scan, tap the [Model] icon to edit it. 1 Auto WB Auto Continuous Model 08 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED NearExcellentGoodFarExcellentGoodFar?MIRACO Quick Start Guide Step 2: One-tap Edit and Manual Edit 1) One-tap Edit Tap the [One-tap Edit] button to automatically perform point cloud Fusion, Mesh, and Texture (when Color mode is enabled). Its recommended to select One-tap Edit for 3D scanner beginners. 2) Manual Edit Tap the [Fusion], [Mesh], [Texture] in sequence to adjust the corresponding parameters and process the scan. High/Feature/General Camera Module: Near 0000000000000 Raw Data Fused Meshed Textured 1<
<4/
One-tap Edit Fusion Mesh Texture Refer to Revopoint Official Website (https://www.revopoint3d.com/pages/support-miraco) for MIRACOs User Manual for detailed parameter adjustment. Software Update Step 1: Swipe down from the top of the screen, tap [Settings] > [WLAN], and connect to a network. 45%
Storage WLAN Screen Rotation Settings Screenshot Screen Recording Shut Down C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 09 BackResume MIRACO Quick Start Guide Step 2: Tap [Software Update] to check if a new version is available. If yes, tap [Download and Install] to update it. Step 3: The update will install automatically. After the update, MIRACO will restart. Procedure:
[Settings] > [WLAN] > Connect to a network > [Software Update] > [Download and Install] > MIRACO restarts Skills Using Single Shot Mode Step 1: Tap [Single Shot] to switch to it. Step 2: Adjust exposure and other scan parameters. Step 3: Tap the capture button to record a single frame.
Model 1 Auto WB Auto Scan the QR code for a Single-shot Video. 10 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED ContinuousNearExcellentGoodFarExcellent RGB Cameras Exposure Settings Using Marker Mode MIRACO Quick Start Guide Scanning objects with simple geometric features, like a football or wine bottle, requires using Magic Mat, markers, or reference objects and scanning in Marker Alignment. Adjust Scan Settings on MIRACO as below:
Scan Settings OK Accuracy High Standard High-speed (16 fps) Continuous Alignment Feature Marker Object Type General Color Model Place the Markers (or Magic Mat under the object) on or around the objects surface irregularly and ensure there are at least 5 Markers per frame for the entire scan, or the scanner will lose track. C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 11 Far MIRACO Quick Start Guide File Transfers Via USB Cable Step 1: Connect your MIRACO to a computer using the USB Type-C Cable. Step 2: See the popup on MIRACOs screen and tap [Data Transfer]. Step 3: Find files on your computer. 1) Export Projects Open Revo Scan 5 on your PC, and make sure its V 5.4.1 or after. Check the target Projects and click Export on your PC. Note: Both Windows and macOS PCs are supported. 2) Find Screenshots and Screen Recordings (ONLY works on Windows PCs) Windows: Right-click the Windows icon on the toolbar, then click File Explorer. Expand This PC, and locate your hard drive. Then, find the MIRACO. Copy MIRACOs data to your PC. Path: Windows icon > File Explorer >This PC > MIRACO > Internal shared storage > Copy MIRACO's data This PC > MIRACO > Internal shared storage Search Internal shared storage Projects Screenshots Screenrecordings Project: An album including the scanning configuration, Raw data, processed data, and user operation history in memory or hard disk. Each project can include one or more 3D models. 12 C 2023 REVOPOINT 3D ALL RIGHTS RESERVED RGB Cameras Exposure Settings MIRACO Quick Start Guide Connecting to an External Screen MIRACO supports the DisplayPort (DP) interface by using the type-c port. Method 1: A monitor or TV can be connected to MIRACO's Display Port (DP) via its USB Type-C port. MIRACO D SCANNER A monitor or TV Self-provided Method 2: Use the DP to HDMI Adapter (included with MIRACO Pro) to connect MIRACO to an HDMI cable on a TV or monitor. Adapter A monitor or TV MIRACO D SCANNER HDMI Cable Self-provided C 2023 REVOPOINT 3D ALL RIGHTS RESERVED 13 FCC SAR Warning This radio is designed for and classified as General population/uncontrolled Use, the guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health.The exposure standard for wireless radio employs a unit of measurement known as the Specific Absorption Rate, or SAR, the SAR limit set 1.6W/kg. Body-worn operation; this device was tested for typical body-worn operations with the Back of theproduct kept 0mm for body worn. To maintain compliance with RF exposure requirements, use accessories that maintain a 0mm for body worn. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements, and should be avoided. The highest reported SAR value for worn on the body is 0.655 W/kg and Simultaneous SAR is 1. 259 W/kg FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. IC Warning This device complies with Industry Canadas licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada . Son fonctionnement est soumis aux deux conditions suivantes :
( 1 ) Ce dispositif ne peut causer d'interfrences ; et
( 2 ) Ce dispositif doit accepter toute interfrence , y compris les interfrences qui peuvent causer un mauvais fonctionnement de l'appareil. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. L'appareil a t valu pour rpondre aux exigences gnrales d'exposition aux RF. L'appareil peut tre utilis sans restriction dans des conditions d'exposition portables. IC Warning This device complies with Industry Canadas licence-exempt RSS. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes :
( 1 ) Ce dispositif ne peut causer d'interfrences ; et
( 2 ) Ce dispositif doit accepter toute interfrence , y compris les interfrences qui peuvent causer un mauvais fonctionnement de l'appareil. The device for operation in the band 51505350MHz is only for indoor use. This MIRACO meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement This radio is designed for and classified as General population/uncontrolled Use
, the guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health.The exposure standard for wireless radio employs a unit of measurement known as the Specific Absorption Rate, or SAR, the SAR limit set 1.6W/kg. Body-worn operation; this device was tested for typical body-worn operations with the back of the handset kept 0mm for body worn. To maintain compliance with RF exposure requirements, use accessories that maintain a 0mm for body worn. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements, and should be avoided. The highest reported SAR value for worn on the body is 1.259 W/kg. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0mm must be maintained between the users body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna. Cet appareil a t test pour un fonctionnement typique du corps sous pression, pour satisfaire aux exigences relatives lexposition RF, une distance minimale de sparation de 0mm doit tre maintenue entre le corps de lutilisateur et la poigne.Y compris les antennes, les bandes de frquences et les satellites,Des accessoires similaires utiliss par cet appareil ne doivent pas contenir de composants mtalliquesSeule la fourniture ou une antenne agre. Online Support WE ARE HERE FOR YOU Contact Us Follow Us Scan the QR code left with your phone and contact us for help. Forum COPYRIGHT 2023 REVOPOINT 3D ALL RIGHTS RESERVED.This content is subject to change.