all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user manual | Users Manual | 2.29 MiB | August 29 2022 | |||
1 |
|
Internal Photos | Internal Photos | 1.81 MiB | August 29 2022 | |||
1 |
|
External Photos | External Photos | 3.51 MiB | August 29 2022 | |||
1 |
|
Label and Label location | ID Label/Location Info | 1.23 MiB | August 29 2022 | |||
1 |
|
Antenna Test Report | Cover Letter(s) | 1.22 MiB | August 29 2022 | |||
1 | Block | Block Diagram | August 29 2022 | confidential | ||||
1 |
|
FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 60.30 KiB | August 29 2022 | |||
1 |
|
LetterofAuthorizationRev1.0 | Cover Letter(s) | 63.20 KiB | August 29 2022 | |||
1 | OP | Operational Description | August 29 2022 | confidential | ||||
1 |
|
RF Exposure evaluation | RF Exposure Info | 140.71 KiB | August 29 2022 | |||
1 | SCH | Schematics | August 29 2022 | confidential | ||||
1 |
|
Test Report | Test Report | 2.63 MiB | August 29 2022 | |||
1 |
|
Test photos | Test Setup Photos | 2.19 MiB | August 29 2022 |
1 | user manual | Users Manual | 2.29 MiB | August 29 2022 |
PHOENIX 500 Portable Power Station Version A0 APPLICABILITY The User Manual applies to the following product:
PHOENIX 500 Portable Power Station (RPS5080AA-PCS) DISCLAIMER User Manual because continuous product improvements are going to be made. Renogy assumes no responsibility or liability for losses or damages, whether direct, indirect, consequential, or incidental, which might arise out of the use of information in the User Manu-
al. Renogy is not responsible or liable for the failures, damages, or injuries resulting from repair The illustrations in the User Manual are for demonstration purposes only. Details may appear Renogy reserves the right to change the information in the User Manual without notice. COPYRIGHT PHOENIX 500 Portable Power Station User Manual 2022 Renogy. All rights reserved. All information in the User Manual is subject to copyright and other intellectual property rights whole or in part, without the prior written permissions of Renogy and its licensors. TRADEMARKS The following are trademarks or registered trademarks of Renogy in the United States and other countries:
RENOGY All other trademarks in the User Manual are the property of their respective owners and their use herein does not imply sponsorship or endorsement of their products or services. The unau-
thorized use of any trademark displayed in the User Manual or on the product is strictly prohibit-
ed.
- 01 -
Important Safety Instructions Please save these instructions. The User Manual provides important operation and maintenance instructions for PHOENIX 500 Portable Power Station. Please read the User Manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the User Manual can result in electrical shock, serious injury, or death, or can damage PHOENIX, potentially rendering it inoperable. Symbols Used The following symbols are used throughout the User Manual to highlight important information. Indicates a potentially dangerous condition which could result in injury or death. Indicates a critical procedure for safe and proper installation and operation. Indicates an important step or tip for optimal performance. General Safety Information DO NOT immerse PHOENIX in water or leave it out in the rain. DO NOT puncture, drop, crush, penetrate, shake, strike, or step on PHOENIX. DO NOT open, dismantle, repair, tamper with, or modify PHOENIX. DO NO insert foreign objects into the casing or outlets of PHOENIX. Please keep PHOENIX away from heating equipment. DO NOT touch the exposed electrolyte or powder if PHOENIX is damaged. DO NOT use PHOENIX with life support equipment or other medical equipment. Please keep PHOENIX out of the reach of young children. DO NOT dispose of PHOENIX as household waste. Please recycle PHOENIX in accordance with local, state, and federal regulations. Please inspect PHOENIX before each use. Stop using PHOENIX if any visible damages in-
cluding cracks, dents, and deformation or abnormalities including unusual smells and heating are observed.
- 02 -
Please ensure that no water sources including downspouts, sprinklers, or faucets are above or near PHOENIX. Please ensure that snow does not accumulate around PHOENIX. DO NOT lean on, stack anything on top of, or hang anything from PHOENIX or from cables leading to PHOENIX. Please ensure that PHOENIX is securely fastened during transportation.
- 03 -
Table of Contents Product Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 05
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 05 Package Content- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 07 LCD Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 08 Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 10
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 10 DC Home Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 10 Charging - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 13 Powering Devices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 Standby Power Supply (SPS) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 17 Parallel Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 18 Strip Lights Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 19 Timeout Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 19 Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 21 Cleaning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 21 Storage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 21 Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 22
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 27
- 04 -
Product Overview United States
/Canada/Japan Europe/South Korea China United Kingdom Australia
- 05 -
LCD Display LED Strip Lights AC Outlets CIG Port Overload Protector AC Inlet DC Input Port Parallel Outlet
- 06 -
Package Content PHOENIX 500 Portable Power Station AC Power Cable Solar Charge Cable Car Charge Cable User Manual
- 07 -
LCD Display Icon Name Description Indicates the current battery level. As the PHOE-
NIX charges, the ring will light up clockwise with the increasing percentage, and the endmost ring segment will fast flash. Once PHOENIX is fully charged, all the ring segments will light up and re-
main solid. As the PHOENIX discharges, the ring will go out counterclockwise. When the battery lev-
el drops below 10%, the last ring segment will slow Input Power Indicates the amount of power going into PHOE-
NIX. Output Power Indicates the amount of power going out of PHOE-
NIX. Remaining Time Indicates the amount of time before PHOENIX is completely charged or discharged. When PHOE-
NIX idles, the remaining time will show 99 hours. AC Outlet Status the AC Outlet(s).
- 08 -
Icon Name Description CIG Port Status SPS Mode Status WiFi Status Indicates the connection status of the WiFi. Single Phase Parallel Mode Status
allel mode. When the single phase parallel mode is High Temperature Protection Indicates the protection related to high tempera-
tures. Low Temperature Protection Indicates the protection related to low tempera-
tures. Indicates the protection related to the internal bat-
tery. Current Protection Indicates the protection related to current. Voltage Protection Indicates the protection related to voltage. PHOENIX might need special attention if the [High Temperature Protection], [Low Tempera-
Please refer to the Troubleshooting section for detailed instructions.
- 09 -
Operation display the operating status of PHOENIX. go out. DC Home Connection It is required to turn on PHOENIX before connecting it to the DC Home app. Setting Up Scan the QR code to download the DC Home app. Open the DC Home app. Click Sign Up to sign up for a new account.
- 10 -
Bluetooth Connection Click + on the top right corner to search for PHOENIX. Monitor and program PHOENIX on the DC Home app. on the pop-up menu to add PHOENIX to the device list. Please keep the phone or tablet within 65.6 feet (20 m) of PHOENIX. WiFi Connection Click + on the top right corner to search for PHOENIX. Click Clic on the pop-up menu to add PHOENIX to the device list. Select a nearby WiFi network. Enter the WiFi password. Click Connect to connect PHOENIX to the WiFi network. Monitor and program PHOENIX on the DC Home app from anywhere with the internet access.
- 11 -
PHOENIX only connects to the 2.4GHz WiFi network.
- 12 -
Charging DO NOT charge PHOENIX at high temperatures above 113F (45C) or low temperatures below 32F (0C). The recommended charge temperature range is between 32F (0C) and 104F (40C). DO NOT use damaged accessories to charge PHOENIX as it might cause electric shock. ONLY use Renogy approved accessories to charge PHOENIX. DO NOT charge PHOENIX immediately after a long heavy run. Please charge PHOENIX immediately when the battery level drops below 10% to prevent overdischarge. To extent the cycle life, please fully charge PHOENIX before each use. It is not required to turn on PHOENIX manually before charging. PHOENIX turns on automati-
cally once it detects the charging source(s). PHOENIX features 3 charging methods solar, AC, and car. Solar Charging Place a solar panel (sold separately) under direct sunlight. Steer clear of objects that can shade the solar panel and slow down the charging process. Connect the DC Input Port of PHOENIX to the solar connectors of the solar panel with the in-
cluded solar charge cable. PHOENIX will start charging automatically. Multiple solar panels can be connected in series for a higher power rating.
- 13 -
The operating voltage of the solar panel array shall exceed 10V, and the open circuit voltage shall NOT exceed 50V. Please ensure that the solar panels are of the same type and ratings and under similar condi-
tions. PHOENIX automatically limits the input power. It is allowed and recommended to charge PHOENIX with a solar panel array rated above 200W to account for the energy conversion loss. For optimal charging performance, it is recommended to charge PHOENIX with the solar pan-
el array on bright sunny days free of clouds. The solar charge time is highly dependent on the solar irradiance and the ambient tempera-
ture. AC Charging The iTurbo technology enables PHOENIX to be charged up to 80% within 1 hour. Connect the AC Inlet of PHOENIX to a wall outlet with the included AC Power Cable. PHOE-
NIX will start charging automatically. The charging speed is set to fast by default. It can be reduced on the DC Home app for a qui-
eter charging experience.
- 14 -
Car Charging Start the car engine. Connect the DC Input Port of PHOENIX to the CIG port in the car with the included Car Charge Cable. PHOENIX will start charging automatically. Powering Devices DO NOT discharge PHOENIX at high temperatures above 131F (55C) or low temperatures below -4F (-20C). The recommended discharge temperature range is between -4F (-20C) and 104F (40C). PHOENIX can provide a total output power of up to 1050W. Please allocate the output power rationally. DO NOT overload PHOENIX. DO NOT connect high power devices to PHOENIX when it is running low. It is required to turn on PHOENIX before powering devices. low 1050W. PHOENIX might not be able to deliver exact 495Wh energy when powering high power devic-
es CIG, and AC.
- 15 -
USB-A/USB-C Devices will stop powering the devices. speaker, wireless headphone, and drone. held game console, and DSLR camera. support the Quick Charge (QC) standard. support the Power Delivery (PD) standard. Car Powered Devices vice to the CIG Port to start powering the device. stop powering the device.
The CIG Port can power most car powered devices including portable refrigerator, car vacu-
um, car air fan, and CPAP machine. AC Devices devices to the AC Outlets to start powering the devices. The output frequency of the AC Outlets can be switched between 50Hz and 60Hz on the DC Home app. stop powering the devices. The AC Outlets can power most AC devices rated under 800W including laptop, desktop com-
puter, TV, game console, full-size refrigerator, freezer, projector, and portable heater. and electric iron. Home app.
- 16 -
tions. Inappropriate output frequency might damage the device.
heat dissipation when the AC Outlets are in use. PHOENIX might not be able to power the AC devices that require high starting currents even though they are rated under 800W. age limits. Standby Power Supply (SPS)
It is not required to turn on PHOENIX manually before using it as a SPS. PHOENIX turns on automatically once it is connected to a wall outlet. PHOENIX can work as a SPS to deliver emergency AC power to the devices during a power outage. Connect the AC Inlet of PHOENIX to a wall outlet with the included AC Power Cable. Connect the devices to the AC Outlets. The SPS mode will be turned on automatically with the devices powered by the AC power from the wall outlet. In the case of a power outage, PHOENIX will deliver emergency AC power to the devices with a transfer time less than 20ms. DO NOT connect AC devices rated over 800W to PHOENIX for emergency AC power. DO NOT connect AC devices that require a transfer time less than 20ms including data server and workstation to PHOENIX for uninterrupted AC power. Please check the holdup time of the
- 17 -
Parallel Connection It is required to turn on PHOENIXes before connecting them in parallel. The iStack technology allows two PHOENIXes to be connected in parallel to deliver 990Wh ca-
pacity and 1440W AC output. Single Phase Parallel Connect the Parallel Outlets of two PHOENIXes with a single phase parallel kit (sold sepa-
rately). The single phase parallel mode will be turned on after a few seconds of initialization. Connect the devices to the single phase parallel kit to start powering the devices. Through the single phase parallel kit, two PHOENIXes can together power most single phase AC devices rated under 1440W including washing machine, space heater, room air condition-
er, and vacuum. Please ensure that PHOENIXes are of the same models. Please ensure that the AC Outlets of PHOENIXes have the same output voltage and output frequency.
- 18 -
Please read the user manual of PHOENIX Single Phase Parallel Kit before connecting PHOE-
NIXes in parallel. Please fully charge the PHOENIXes before connecting them in parallel. The AC Inlet will be disabled for AC charging and SPS mode when the single phase parallel kit is connected to PHOENIX. It is not recommended to power devices through the AC Outlets when PHOENIXes are con-
nected in parallel. Strip Lights Operation It is required to turn on PHOENIX before using the LED Strip Lights. what lighting mode they are on. The brightness of the LED Strip Lights can be adjusted on the DC Home app. When PHOENIX is charging, the LED Strip Lights will automatically turn on in breath mode by Timeout Settings LCD Display Timeout When no operation is made for 5 minutes, the LCD Display will go out automatically to save energy. The timeout of the LCD Display can be set or disabled on the DC Home app. USB Ports Timeout bled on the DC Home app. CIG Port/AC Outlets Timeout When the device draws low or no power from the CIG Port or AC Outlets for 1 hour, the CIG
- 19 -
The timeout of the CIG Port or AC Outlets can be set or disabled on the DC Home app. Unit Timeout gy. The timeout of PHOENIX can be set or disabled on the DC Home app.
- 20 -
Maintenance Cleaning Remove all the connections from PHOENIX. Clear the leaves, debris, and dust from the fans of PHOENIX. Clean the casing of PHOENIX with a soft dry cloth. Keep the area around PHOENIX clean and dry. Turn PHOENIX back on. Reconnect the devices to PHOENIX. Storage Charge PHOENIX to 50%. Remove all the connections from PHOENIX. Handle PHOENIX carefully to avoid sharp impacts or extreme pressure on the casing of PHOENIX. Store PHOENIX in a well ventilated, dry, clean area with temperatures between -4F (-20C) and 68F (20C) and humidity between 10% and 90%. For long term storage, discharge PHOENIX to 30% and charge it to 50% every 6 months. Fully charge PHOENIX when it is taken out of the storage. DO NOT expose PHOENIX to extreme temperatures above 131F (55C). DO NOT expose PHOENIX to direct sunlight, moisture, or precipitation. Please keep PHOENIX away from water, heat, dust, dirt, corrosives, and metal objects. Please ensure that no metal objects can fall on or around PHOENIX.
- 21 -
Troubleshooting If PHOENIX does not operate properly, refer to the table below for possible causes and cor-
rective steps. If the corrective steps do not work, contact our customer service through renogy.com/con-
tact-us/. Icons Pattern Possible Causes Corrective Steps Slow Flash AC Input Overvoltage/
Undervoltage Overload Protector Pop Up AC Input Overcurrent Slow Flash DC Input Overvoltage/
Undervoltage Disconnect the AC Inlet from the wall outlet. Measure the voltage of the wall outlet. Stop using the wall outlet if its voltage falls outside Connect the AC Inlet to the wall outlet with the appropriate voltage. Charging can be re-
sumed. Disconnect the AC Inlet from the wall outlet. Press down the Overload Protector to reset it. Reconnect the AC Inlet to the wall outlet. Contact us for help if the Overload Protector pops up again. Disconnect the charging source from the DC Input Port. Check the volt age rat ing of the charging source. Stop using the charging source if its output voltage is rated lower than 10V or high-
er than 50V. Connect the charging source with the ap-
propriate voltage rating to the DC Input Port. Charging can be resumed. Slow Flash Charge Output Overvoltage/
Undervoltage LCD Display lit up to release the protection. Contact us for help if the icons persist.
- 22 -
Icons Pattern Possible Causes Corrective Steps Slow Flash Check the current ratings of the devices. Stop using the devices if they draw currents that ex-
Charge Output Overcurrent/Short Circuit Slow Flash Overvoltage/
Undervoltage LCD Display lit up to release the protection. Connect the devices with the appropriate cur-
Fast Charge Port. Power can be resumed. LCD Display lit up to release the protection. Contact us for help if the icons persist. Check the current rating of the device. Stop using the device if it draws current that ex-
Slow Flash Overcurrent LCD Display lit up to release the protection. Connect the device with the appropriate cur-
resumed. Disconnect the device from the CIG Port. LCD Display lit up to release the protection. Reconnect the device to the CIG Port. Contact us for help if the icons persist. Slow Flash CIG Output Overvoltage/
Undervoltage
- 23 -
Icons Pattern Possible Causes Corrective Steps Slow Flash CIG Output Overcurrent/Short Circuit Slow Flash AC Output Overvoltage/
Undervoltage Slow Flash AC Output Overload/Short Circuit Slow Flash Inverter High Temperature Disconnect the device from the CIG Port. Remove the short circuit if the CIG Port is shorted. Check the current rating of the device. Stop using the device if it draws current that ex-
LCD Display lit up to release the protection. Connect the device with the appropriate cur-
rent rating to the CIG Port. Power can be re-
sumed. Disconnect the devices from the AC Outlets. Display lit up to release the protection. Reconnect the devices to the AC Outlets. Contact us for help if the icons persist. Disconnect the devices from the AC Outlets. Remove the short circuit if the AC Outlets are shorted. Check the power ratings of the devices. Stop using the devices if their power ratings are higher than 800W. Display lit up to release the protection. Connect the devic es with the appropriat e power ratings to the AC Outlets. Power can be resumed. Check if the fan inlet and outlet are blocked. Cool down PHOENIX to the room temperature. Display lit up to release the protection. Power can be resumed.
- 24 -
Icons Pattern Possible Causes Corrective Steps Reallocate the output power to ensure that the total output power is under 1050W. Slow Flash Total Output Overload LCD Display lit up to release the protection. Power can be resumed. Disconnect all the connections from PHOE-
NIX. Check if the fan inlet and outlet are blocked. Cool down PHOENIX to the room temperature. Reconnect the charging source(s) to PHOE-
NIX. Charging can be resumed. Power can be resumed. Warm up PHOENIX. Charging can be resumed automatically. Power can be resumed. Slow Flash Temperature Slow Flash Temperature
- 25 -
Icons Pattern Possible Causes Corrective Steps Disconnect the single phase parallel kit from PHOENIXes. Check the models of PHOENIXes. Stop con-
necting PHOENIXes in parallel if they are of Fast Flash Single Phase Parallel Failure Check the output voltages of the AC Outlets. Stop connecting PHOENIXes in parallel if their Switch the AC Outlets of PHOENIXes to the same output frequency. Fully charge PHOENIXes. Reconnect PHOENIXes in parallel with the single phase parallel kit.
- 26 -
Dimension Weight 12.76 x 8.19 x 9.43 inch / 324 x 208 x 239.5 mm 16.71 lbs / 7.6 kg General Charge Temperature Discharge Temperature Storage Temperature
-4F~68F / -20C~20C Type Capacity Cycle Life AC Input DC Input put (x1) Battery Lithium Ion 18V, 27500mAh / 495Wh 600 Cycles (80% DOD, 80% EOL) Input 85V~120V (JP)/90V~140V (US, CA)/200V~240V (EU, UK, AU, KR, CN) 45Hz~55Hz/57Hz~65Hz, 495W Max 10V~50V 10A, 200W Max Output 5V 2.4A, 12W Max
5V 3A, 9V 2A, 12V 1.5A, 18W Max 5V 3A, 9V 3A, 12V 3A, 15V 3A, 20V 5A, 100W Max CIG Output (x1) 13.6V 10A, 136W Max AC Output (x2/x3) 100V (JP)/120V (US, CA)/220V~240V (EU, UK, AU, KR, CN) 50Hz/60Hz, 800W Rated, 1600W Surge Total Output 1050W Max
- 27 -
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
dna ,ecnerefretni lufmrah esuac ton yam ecived sihT )1(
nu esuac yam taht ecnerefretni gnidulcni ,deviecer ecnerefretni yna tpecca tsum ecived sihT )2(
desired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec-
tion against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
ing measures:
.annetna gniviecer eht etacoler ro tneirO )1(
.reviecer dna tnempiuqe eht neewteb noitarapes eht esaercnI )2(
connected. pleh rof naicinhcet VT/oidar decneirepxe na ro relaed eht tlusnoC )4(
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC RADIATION EXPOSURE STATEMENT This equipment complies with FCC radiation exposure limits set forth for an uncontrolled en-
vironment. This equipment should be installed and operated with minimum distance 20cm be-
tween the radiator & your body. IC STATEMENT
- 28 -
RENOGY.COM Renogy reserves the right to change the contents of this manual without notice. R210-
189209 FCC ID: 2ANPB-RPS5080AA IC ID: 23590-RPS5080AA US CN 5050 S Archibald Ave, Ontario, CA 91762 909-287-7111 www.renogy.com support@renogy.com 400-6636-695 https://www.renogy.cn support@renogy.cn JP https://www.renogy.jp supportjp@renogy.com CA https://ca.renogy.com supportca@renogy.com AU UK DE https://au.renogy.com supportau@renogy.com https://uk.renogy.com supportuk@renogy.com https://de.renogy.com supportde@renogy.com
1 | Label and Label location | ID Label/Location Info | 1.23 MiB | August 29 2022 |
RENOGY Slo Cee sce, SX Ome 18V, 27500mAh/495Wh 10V-50V = 10A, 200W Max 85V-120V {3P)/90V-140V (US,CA)/200V-240V (EU, UK, AU, KR, CN) 45Hz-SSHz/57Hz-6SHz, 495W Max SV = 2.4A, 12W Max SV = 3A, 9V = 2A, 12V = 155A, 18W Max SV = 3A, 9V = 3A, 12V = 3A, ISV = 3A, 20V = SA, 1]OOW Max T3.6V =10A,136W Max 100V (3P/I20V (US, CA)/220V-240V (EU, UK, AU, KR, CN)~
" SOHz/60Hz, 800W Rated, 1600W Surge 4050W Max Gan Ge &:
189209 &
UN38.3 eVatmaster Consulting GmbH EC Battinastr. 30 60325 Frankfurt am Main, Germany f contact@evatmaster.com SRS RRNA | EVATOST CONSULTING LTD
@S.rlem T Bieee Claar h4ras Daal Riscinece FCC ID:
IC 1D:
EEE ee - ees Sl >. wSETES FEL EF . wr SSS eee
: 4 UK REP Centre, Taffs Weill, Cardiff Wales, CFIS 5 7QR
: . contact@evatmaster.com i WARNING
* DO NOT disassemble, alter, crush, puncture , or incinerate. DO NOT place near fire or heat. 13530 Refer to socal mene for disposal. RPSSOBOAA-PCS Battery Type:
Battery Capacity:
De Input:
4C Input:
USB-A Output:
USB-A Fast Charge Output:
USB-C Output 1G Output:
AC Output:
Total Output:
WARNING rENOGY Lithium fon 18V, 27500mAh/495Wh TOV-5OV = 10, 200W Max 85V-120V (JP)/90V-140V (US,CA)/200V-240V (EU, UK, AU, KR, CN)=
45Hz-S5Hz/S7H2-65Hz, 495W Max 5V=2.4A, 12W Max 5V-=3A,9V=2A, 12V= 158, 18W Max SV=5A, 9V.=3A, 12V== 3A, 15V= 3A, 20V= 5A, ]00W Max T6V -=10A, 136W Max TOOV (2P//I20V (US, CA)/220V-240V (EU, UK, AU, KR, CN}
S0Hz/60Hz, 800W Rated, 160OW Surge 1OS0W Max
+ DONOT disassemble, alter, crush, puncture , or incinerate,
+ DO NOT place near fire or heat.
+ Refer to local regulations for disposal, FEIC RCE MM we, Gh 189209 EC REP UK REP 10:
Ht UN38.3 eVatmmaster Consulting Battinastr 30 60525 Frankfurt am Main, Germany EVATOST CONSULTING LTD. Suite Tl, First Fleer, Moy Road Business Cent Well, Cardiff, Wales, CF RENOGY JAPANPEAE RL FCC ID: 2ANPB-RPSSOB0AA IC ID: 23590-RPSSOB0AA 4 5.1 SN FEAR eESAL 5.1.1SN SABES 18 fiZ, RDTRHAS MAS Sank. 51.2 S950:
XXXXXXXXXXXXXXXXXX 38 13 BIB 18 (uy, BHO fi, Arka Hes 11 BUSS 12 fiz, watt 2 fil, ARABS 38 8 BUS 10 fz, HEB fi, AGES
1 | Antenna Test Report | Cover Letter(s) | 1.22 MiB | August 29 2022 |
Report No.: BL-SZ2280702-901 TEST REPORT Applicant:
Guangzhou ZHIYUAN Electronics Co., Ltd. Address:
ZLG Zhiyuan Electronics Building, No. 43 Sicheng Road, Tianhe District, Guangzhou, Guangdong Province Equipment Type:
Wi-Fi Module Model Name:
ZM602P2S31P Brand Name:
ZLG Test Standard:
GB/T 9410-2008 (refer section 3.1) Test Date:
Jun. 10, 2022 Date of Issue:
Aug. 18, 2022 ISSUED BY:
Shenzhen BALUN Technology Co., Ltd. Tested by: Mai Jintian Checked by: Tolan Tu Approved by: Wei Yanquan
(Chief Engineer) _______________ _______________ _______________ Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 1 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 Revision History Version Issue Date Rev. 01 Aug. 18, 2022 Revisions Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 4 1.1 Test Laboratory ..................................................................................................................... 4 1.2 Test Location ......................................................................................................................... 4 2 PRODUCT INFORMATION ......................................................................................................... 5 2.1 Applicant Information ............................................................................................................ 5 2.2 Manufacturer Information ...................................................................................................... 5 2.3 Factory Information ............................................................................................................... 5 2.4 General Description for Equipment under Test (EUT) .......................................................... 5 2.5 Ancillary Equipment .............................................................................................................. 5 2.6 Technical Information ............................................................................................................ 5 3 SUMMARY OF TEST RESULTS ................................................................................................. 6 3.1 Test Standards ...................................................................................................................... 6 3.2 Test Verdict ........................................................................................................................... 6 3.3 Test Uncertainty .................................................................................................................... 6 4 GENERAL TEST CONFIGURATIONS ........................................................................................ 7 4.1 Test Condition ....................................................................................................................... 7 4.2 Test Equipment List .............................................................................................................. 7 4.3 Test Setup ............................................................................................................................. 8 ANNEX A TEST RESULTS ........................................................................................................... 10 A.1 Gain and Efficiency ............................................................................................................. 10 A.2 VSWR ................................................................................................................................. 11 A.3 Return Loss ......................................................................................................................... 12 A.4 Input Impedance ................................................................................................................. 13 ANNEX B RADIATION PATTERN ................................................................................................ 14 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 2 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 ANNEX C TEST SETUP PHOTO ................................................................................................. 17 ANNEX D EUT PHOTO ................................................................................................................ 19 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 3 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 1 GENERAL INFORMATION 1.1 Test Laboratory Name Address Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Phone Number
+86 755 6685 0100 1.2 Test Location Name Shenzhen BALUN Technology Co., Ltd. Location Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 4 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address Guangzhou ZHIYUAN Electronics Co., Ltd. ZLG Zhiyuan Electronics Building, No. 43 Sicheng Road, Tianhe District, Guangzhou, Guangdong Province Contact Person Lin Youlian Telephone Number 13424989034 E-mail Address zy.emc@zlg.cn 2.2 Manufacturer Information Manufacturer Guangzhou ZHIYUAN Electronics Co., Ltd. Address ZLG Zhiyuan Electronics Building, No. 43 Sicheng Road, Tianhe District, Guangzhou, Guangdong Province 2.3 Factory Information Factory Address N/A N/A 2.4 General Description for Equipment under Test (EUT) Wi-Fi Module EUT Name Model Name Under Test ZM602P2S31P Antenna Type Dimensions PCB Antenna 16*7 mm 2.5 Ancillary Equipment Note: Not applicable. 2.6 Technical Information Frequency Range 2400MHz ~ 2500MHz Test Frequencies 2400MHz, 2410MHz, 2420MHz, 2430MHz, 2440MHz, 2450MHz, 2460MHz, 2470MHz, 2480MHz, 2490MHz, 2500MHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 5 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. 1 2 3 Identity GB/T 9410-2008 Document Title General specification for antennas used in the mobile communications ANSI/IEEE Std 149-1979 IEEE Standard Test Procedures for Antennas Enterprise Technology Method Enterprise Technology Method refer Section 4.3 3.2 Test Verdict Report Section ANNEX A.1 ANNEX A.2 ANNEX A.3 ANNEX A.4 ANNEX B Description Gain and Efficiency VSWR Return Loss Input impedance Radiation Pattern Identity GB/T 9410-2008 GB/T 9410-2008 Enterprise Technology Method ANSI/IEEE Std 149-1979 GB/T 9410-2008 Remark Note#2 Note#2 Note#1, Note#2 Note#2 Note#2 Note#1: The return loss test method is based on Section 4.3.3 of this report. Note#2: Compared with the EUT of test report(BL-SZ2260417-901), the EUT of this report is the same one. Therefore, all test datas originate from report(BL-SZ2260417-901), which was issued by Shenzhen BALUN Technology Co., Ltd. on 2022, Jun. 23. 3.3 Test Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Item VSWR(S11) Gain Uncertainty 0.61 1.92dB Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 6 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 4 GENERAL TEST CONFIGURATIONS 4.1 Test Condition Selected Values During Tests Ambient Pressure(KPa) Temperature() Voltage Relative Humidity (%) 100 to 102 19 to 25 N/A 45 to 55 Environment Parameter Normal Temperature, Normal Voltage
(NTNV) 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due SG24 Multi-probe Antenna Measurement System Vector Network Analyzer SATIMO SG24-L 1101855-
0001 2021.11.12 2024.11.11 Agilent E5071B MY42404001 2022.04.02 2023.04.01 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 7 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 4.3 Test Setup 4.3.1 Antenna gain, efficiency and radiation pattern test setup 4.3.2 S11 parameter test setup Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 8 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 4.3.3 Return Loss Test Method 1) The connection diagram between the antenna under test and the measuring system is shown in Chapter 4.3.2. The nominal impedance of return loss measuring equipment is 50 ;
2) Calibration of the measuring system: perform system calibration according to the calibration steps of the test instrument, and the interface of the test end shall match the interface of the antenna under test;
3) Connect the measuring system with the antenna under test, and measure the return loss within the working frequency range. The measured loss reading is the return loss of the measured antenna port. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 9 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 ANNEX A TEST RESULTS A.1 Gain and Efficiency Frequency 2400MHz 2410MHz 2420MHz 2430MHz 2440MHz 2450MHz 2460MHz 2470MHz 2480MHz 2490MHz 2500MHz Gain (dBi) Efficiency (%) 3.40 3.36 3.31 3.28 3.19 3.16 3.03 3.00 3.04 3.07 3.02 81 80 79 80 80 78 77 77 78 76 75 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 10 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 A.2 VSWR Frequency 2400MHz 2450MHz 2500MHz VSWR 1.44 1.61 1.80 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 11 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 A.3 Return Loss Frequency 2400MHz 2450MHz 2500MHz Return Loss (dB)
-19.77
-13.79
-11.80 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 12 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 A.4 Input Impedance Frequency 2400MHz 2450MHz 2500MHz Input impedance () 40.96 37.06 38.95 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 13 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 ANNEX B RADIATION PATTERN B.1 3D Pattern B1.1 3D Pattern for 2400MHz B1.2 3D Pattern for 2450MHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 14 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 B1.3 3D Pattern for 2500MHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 15 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 B.2 1D Radiation Pattern B2.1 PHI=0 B2.2 PHI=90 B2.3 THETA=90 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 16 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 ANNEX C TEST SETUP PHOTO Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 17 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 18 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 ANNEX D EUT PHOTO Antenna Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 19 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2280702-901 Statement 1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the inspection and testing dedicated stamp or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report.
--END OF REPORT--
Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 20 / 20 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China
1 | FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 60.30 KiB | August 29 2022 |
RNG International Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2ANPB-RPS5080AA Date: 2022-08-23 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description SW SECURITY DESCRIPTION Parts List Tune up In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: jason jiang Title: CTO
1 | LetterofAuthorizationRev1.0 | Cover Letter(s) | 63.20 KiB | August 29 2022 |
RNG International Inc. Letter of Authorization Company: RNG International Inc. Address: 5050 S Archibald Ave, Ontario, California, 91762, United States Product Name: Phoenix 500 Portable Power Station Model Number(s): RPS5080AA-PCS Product Description: Phoenix 500 Portable Power Station We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Name:
jason jiang Title:
CTO Company: RNG International Inc. Date: 2022-08-23
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-08-29 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-08-29
|
||||
1 | Applicant's complete, legal business name |
RNG International Inc.
|
||||
1 | FCC Registration Number (FRN) |
0026824391
|
||||
1 | Physical Address |
5050 S Archibald Ave
|
||||
1 |
Ontario, CA
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ANPB
|
||||
1 | Equipment Product Code |
RPS5080AA
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
j****** j****
|
||||
1 | Telephone Number |
90951********
|
||||
1 | Fax Number |
88854********
|
||||
1 |
j******@renogy.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
RNG International Inc.
|
||||
1 | Physical Address |
United States
|
||||
1 |
j******@renogy.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Phoenix 500 Portable Power Station | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted power. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 | Name |
J**** Z******
|
||||
1 | Telephone Number |
86-75********
|
||||
1 | Fax Number |
86-75********
|
||||
1 |
j******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0013000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC