all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Installation Instructions | Users Manual | 528.77 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Installation Instructions | Users Manual | 528.77 KiB |
MONTAGE INSTALLATION RWF1
(deutsch / english) final public (B) 2011-07-27 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D H S I L G N E deutsche Version ab Seite 3 english version from page 16 FEIG ELECTRONIC GmbH Seite 2 von 31 M90900-4de-ID-E.doc OBID i-scan Montage Hinweis Copyright 2010-11 by FEIG ELECTRONIC GmbH Lange Strae 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de RWF1 H C S T U E D Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Dokument knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt weder Gewhr fr die einwandfreie Funktion in system-
fremden Umgebungen, noch fr die Funktion eines Gesamtsystems, welches die in diesem Dokument be-
schriebenen Gerte enthlt. FEIG ELECTRONIC weist ausdrcklich darauf hin, dass die in diesem Dokument beschriebenen Gerte nicht fr den Einsatz mit oder in medizinischen Gerten oder fr Gerte fr lebenserhaltende Manahmen konzipiert sind, bei denen ein Fehler eine Gefahr fr menschliches Leben oder fr die gesundheitliche Un-
versehrtheit zur Folge haben kann. Der Applikationsdesigner ist dafr verantwortlich geeignete Manahmen zu ergreifen um Gefahren, Schden oder Verletzungen zu vermeiden. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID und OBID i-scan ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH my-d ist ein eingetragenes Warenzeichen der Infineon Technologies AG I-CODE und mifare ist ein eingetragenes Warenzeichen der Philips Electronics N.V. Tag-it ist ein Warenzeichen der Texas Instruments Incorporated FEIG ELECTRONIC GmbH Seite 3 von 31 M90900-4de-ID-E.doc RWF1 5 6 OBID i-scan H C S T U E D Montage Inhalt 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 2 Leistungsmerkmale des Readermoduls RWF1 2.1 Leistungsmerkmale .................................................................................................... 6 2.2 Lieferumfang ............................................................................................................... 6 3 Montage und Anschluss 7 3.1 Abmessungen ............................................................................................................. 7 3.2 Anschlussbelegung X9 .............................................................................................. 8 3.2.1 Spannungsversorgung .................................................................................................. 9 3.2.2 RS232-Schnittstelle ...................................................................................................... 9 3.2.3 Anschluss der externen Antennen .............................................................................. 10 3.3 Montagehinweise ...................................................................................................... 11 3.3.1 Montage ..................................................................................................................... 11 3.3.2 Beeinflussung ............................................................................................................. 11 3.3.3 EMV-Beeinflussung ber Zuleitungen ......................................................................... 12 3.3.4 EMV-Beeinflussung ber magnetische Felder ............................................................ 12 4 Technische Daten 13 4.1 Zulassung .................................................................................................................. 15 4.1.1 Europa (CE) ................................................................................................................ 15 FEIG ELECTRONIC GmbH Seite 4 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektri-
sche Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschlu der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Ein-
stellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird keine Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschlu-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von Elekt-
rofachkrften mit einschlgiger Ausbildung erfolgen. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationa-
len elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet wer-
den. Besonderer Hinweis fr Trger von Herzschrittmachern:
Obwohl dieses Gert die zulssigen Grenzwerte fr elektromagnetische Felder nicht ber-
schreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gert und Ihrem Herz-
schrittmacher einhalten und sich nicht fr lngere Zeit in unmittelbarer Nhe des Gerts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 5 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D 2 Leistungsmerkmale des Readermoduls RWF1 2.1 Leistungsmerkmale Das Readermodul RWF1 ist fr das Lesen und Schreiben von passiven Transpondern mit einer Betriebsfrequenz von 13,56 MHz nach ISO/IEC 15693 Norm entwickelt worden. Es eignet sich fr alle Anwendungen, bei denen geringe Lesereichweiten bei kleinen Abmessungen des Readermoduls bentigt werden. Das Readermodul verfgt ber einen internen Antennenmultiplexer. Es knnen bis zu 8 externe Antennen an das Modul angeschlossen werden. 2.2 Lieferumfang Folgende Komponenten sind im Lieferumfang enthalten:
Modultyp RWF1 Tabelle 1: Lieferumfang Lieferumfang 1 x Readermodul RWF1 FEIG ELECTRONIC GmbH Seite 6 von 31 M90900-4de-ID-E.doc RWF1 H C S T U E D OBID i-scan Montage 3 Montage und Anschluss 3.1 Abmessungen Bild 1 zeigt die Mazeichnung des Readermoduls RWF1 Bild 1: Mazeichnung des Readermoduls RWF1 FEIG ELECTRONIC GmbH Seite 7 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D 3.2 Anschlussbelegung X9 Bild 2 und Tabelle 2 zeigen die Belegung der Anschlusssbuchse X9. Die Anschlusssbuchse X9 ist fr einen Kabelanschluss mittels 6-poligen Anschlussstecker vom Typ Molex MicroFit ausgelegt. Bild 2 Anschlussbuchse Molex MicroFit, 6Pol. X9 Pin-Nr. Kurzzeichen Beschreibung 1 2 3 4 5 6 GND TxD
RxD
Ground RS232 - Sendedaten N.C. RS232 - Empfangsdaten N.C. VCC*
24VDC Spannungsversorgung
Nur geregelte DC-Spannungen verwenden !
Tabelle 2: Belegung der Anschlussstiftleiste X9 HINWEIS:
Eine Verpolung des Steckers kann zur Zerstrung des Gertes fhren. FEIG ELECTRONIC GmbH Seite 8 von 31 M90900-4de-ID-E.doc RWF1 H C S T U E D OBID i-scan 3.2.1 Spannungsversorgung Montage Fr die Spannungsversorgung des RWF1 drfen nur geregelte DC-Spannungen verwendet werden. Im Falle von getakteten Netzteilen zur Versorgung des Readermoduls ist auf eine ausreichende Filterung der Versorgungsspannung zu achten. Strungen der Versorgungsspannung knnen sich in einer Reduzierung der Lese- und Schreib-
reichweite des Readermodules auswirken. Die Lnge des Zuleitungskabels der Spannungsversorgung sollte mglichst kurz sein und sollte 10 m nicht berschreiten. Es sollte ein paarweise verdrilltes Kabel verwendet werden. HINWEISE:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. Versorgungsspannungen auerhalb der Spezifikation knnen zur Zerstrung des Ger-
tes fhren. 3.2.2 RS232-Schnittstelle Die Lnge des Zuleitungskabels der RS232-Schnittstelle sollte mglichst kurz sein und darf 10 m nicht berschreiten. Die Abhngigkeit von der Baudrate ist zu bercksichtigen. Die bertragungsparameter der Schnittstelle sind konfigurierbar. Tabelle 3 zeigt die Werkseinstellung der RS232-Schnittstelle. Parameter Baudrate Standardeinstellung 38400 bit/s Anzahl der Datenbits 8 Paritt Even Anzahl der Stoppbits 1 Tabelle 3: Werkseinstellung der RS232-Schnittstelle. FEIG ELECTRONIC GmbH Seite 9 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D 3.2.3 Anschluss der externen Antennen Es knnen bis zu 8 externe Antennen angeschlossen werden. Zum Anschluss der externen Antennen befinden sich 8 Antennenbuchsen (A1...A8) auf der Leiter-
platte. Diese sind vom Typ MMCX. Hinweise:
Bild 3 Antennenanschluss Die maximale Antennenzuleitung sollte 150 cm nicht berschreiten. Bei Kabellngen >
100cm ist mit Lesereichweitenverlusten bis zu 10% zu rechnen. Die Eingangsimpedanz der Antenne ist auf einen Wert von 50 3 und einem Winkel von 0 3 abzugleichen. Eine nicht abgeglichene Antenne kann zur Zerstrung des Gertes fhren. Die optimale Betriebsgte der Antenne sollte im Bereich QB = 10...20 liegen. Zur Ermitt-
-Quelle, z.B. einem Network Ana-
lung der Betriebsgte muss die Antenne mit einer 50 lyzer oder einem Frequenzgenerator, versorgt werden. Beim Anschluss einer Antenne ist darauf zu achten, dass diese die zulssigen Grenz-
werte der nationalen Vorschriften bezglich Funkanlagen nicht berschreitet. FEIG ELECTRONIC GmbH Seite 10 von 31 M90900-4de-ID-E.doc OBID i-scan Montage 3.3 Montagehinweise Das Antennenmodul ist fr den Einbau in andere Gerte konzipiert. 3.3.1 Montage RWF1 H C S T U E D Das Antennenmodul ist fr Schrauben mit einem Gewindedurchmesser M2,5 konzipiert. Bauteilseite des Readermoduls Zum befestigen sind Schrauben zu verwenden, deren Kopf einen Durchmesser von 6mm nicht berschreitet. Bevorzugt werden nicht metallische Schrauben nach DIN 7985 Alternative Schrauben mit Innensechskant nach DIN 912 Unterseite des Readermoduls Leitende Materialien drfen ein maximalen Durchmesser von 6mm haben Nicht leitende Materialien drfen ein maximalen Durchmesser von 10mm haben Die Einbaulage des Antennenmoduls frei whlbar. Die bevorzugte Einbaulage ist jedoch mit der Bauteilseite nach oben. Prfen Sie vor der endgltigen Installation den geplanten Montageort auf seine Tauglichkeit. 3.3.2 Beeinflussung Folgende mgliche Beeinflussungen durch die Umgebung sollten beim Einbau des Antennenmo-
duls in ein anderes Gert beachtet werden :
Beeinflussung durch eine metallische Umgebung Verstimmung der externen Antenne Beeintrchtigung der Ausbreitung des magnetischen Feldes der Antenne EMV-Beeinflussung ber Zuleitungen Beeintrchtigung der Kommunikation zwischen Readermodul und Transponder EMV-Beeinflussungen ber magnetische Felder Beeintrchtigung der Kommunikation zwischen Readermodul und Transponder FEIG ELECTRONIC GmbH Seite 11 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 3.3.3 EMV-Beeinflussung ber Zuleitungen H C S T U E D Trotz der internen EMV-Filter innerhalb des Readermoduls kann es durch starke Strungen auf der Spannungsversorgung zu Beeintrchtigungen der Kommunikation zwischen Readermodul und Transponder kommen. Dabei wird vor allem der Empfang der Rckantwort des Transponders ge-
strt. Beim Einbau des Readermoduls in ein anderes Gert sollte daher auf eine mglichst saubere, strfreie Spannungsversorgung geachtet werden. 3.3.4 EMV-Beeinflussung ber magnetische Felder Da im vorliegenden Fall der RFID-Technik die Kommunikation zwischen Readermodul und Trans-
ponder mittels der Modulation eines magnetischen Feldes abluft, knnen sich magnetische Wechselfelder in der Nhe der Antenne negativ auf dessen Funktion auswirken. Zu den Quellen solcher magnetischen Strfelder gehren zum Beispiel Spulen innerhalb eines primr oder sekundr getakteten Netzteils. Bei der Festlegung der Position von Readermodul und Antenne in einem Gert sollte dieses auf eventuelle Strquelle in der oben angegebenen Form untersucht werden. Notfalls sind Abschirm-
manahmen zur Unterdrckung einer solchen Strquelle anzuwenden. FEIG ELECTRONIC GmbH Seite 12 von 31 M90900-4de-ID-E.doc OBID i-scan Montage RWF1 H C S T U E D 4 Technische Daten Mechanische Daten Gehuse vergossen Abmessungen ( B x H x T ) 90 x 62 x 18,6 mm Gewicht 77 g Anschlussstecker 6poliger Molex MicroFit 6 Stecker Elektrische Daten Spannungsversorgung 24V DC 10%
Stromaufnahme max. 100mA Leistungsaufnahme max. 2 Watt Betriebsfrequenz 13,56 MHz Sendeleistung 200mW 1dB Antennenanschluss bis zu 8 externe Antennen (50Ohm)
(Anschluss: MMCX-Stecker) Max. Lnge 1,5m (Ab 1m ist mit Lesereichweitenverlusten bis zu 10% rechnen) Schnittstellen RS232 (V24) (Max. Kabellnge 10m) Funktionelle Eigenschaften Protokoll Modi Untersttzte Transponder FEIG ISO HOST ISO15693 EEPROM (fr Parameter) 1kB (10.000 Schreibzyklen) FLASH 64 kB (Firmware Update ber Interface mglich) FEIG ELECTRONIC GmbH Seite 13 von 31 M90900-4de-ID-E.doc H C S T U E D OBID i-scan Montage RWF1 Umgebungsbedingungen Temperaturbereich
- Betrieb
- Lagerung
-20C to +70C
-40C to +85C Relative Luftfeuchtigkeit 5 bis 95% nicht betauend Angewendete Normen Zulassung Funk
- Europa
- USA
- Canada
- Japan EMC Sicherheit EN 300 330-1/-2 EN 302 291 FCC 47 CFR Part 15 IC RSS 210 Issue 8 Radio ordinance item 3 article 44-1 EN 300 489-1/-3 EN 61326-1/-2-6 EN 60950 EN 62311 FEIG ELECTRONIC GmbH Seite 14 von 31 M90900-4de-ID-E.doc OBID i-scan 4.1 Zulassung 4.1.1 Europa (CE) Montage RWF1 H C S T U E D Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom Mrz 99. Equipment Classification gem ETSI EN 300 330 und ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Seite 15 von 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 Note Copyright 2010-11 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this ma-
nual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. I-CODE is a registered trademark of Philips Electronics N.V. Tag-itTM is a registered trademark of Texas Instruments Incorporated. FEIG ELECTRONIC GmbH Page 16 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 1 2 Contents Safety Instructions / Warning - Read before start-up !
Performance Characteristics of the RWF1 Reader Module 18 19 2.1 Performance Characteristics ................................................................................... 19 2.2 Available module ...................................................................................................... 19 3 Installation and wiring 20 3.1 Dimensions ............................................................................................................... 20 3.2 Wiring ........................................................................................................................ 21 3.2.1 Supply voltage........................................................................................................ 22 3.2.2 RS232-Interface ..................................................................................................... 23 3.2.3 Connection of the external antennas ...................................................................... 24 3.3 Installation notes ...................................................................................................... 25 3.3.1 Mounting ................................................................................................................ 25 3.3.2 Influence ................................................................................................................ 25 3.3.3 EMC effects on cables ........................................................................................... 25 3.3.4 EMC effects from magnetic fields ........................................................................... 26 4 5 Technical Data Radio Approvals 27 29 5.1 Europe (CE) ............................................................................................................... 29 6 Annex 31 6.1 Accessories .............................................................................................................. 31 FEIG ELECTRONIC GmbH Page 17 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 1 Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time. FEIG ELECTRONIC GmbH Page 18 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 2 Performance Characteristics of the RWF1 Reader Module 2.1 Performance Characteristics The RWF1 reader module is designed for reading and writing passive transponders, so-called Smart Labels, with an operating frequency of 13.56 MHz according to the ISO15693 standard. It is suitable for any application in which short read ranges and small reader dimensions are re-
quired. The module has an integrated antenna multiplexer. Up to 8 external antennas can be connected. 2.2 Available module The following reader types are available:
Module type Description RWF1 1 x Reader module RWF1 (RWF1) Table 1: Available module version FEIG ELECTRONIC GmbH Page 19 of 31 M90900-4de-ID-E.doc H S I L G N E Mounting Instruction RWF1 OBID i-scan 3 Installation and wiring 3.1 Dimensions Fig. 1 shows the dimensions of the RWF1 Reader Module in mm. Fig. 1: Scale drawing of the reader module RWF1 FEIG ELECTRONIC GmbH Page 20 of 31 M90900-4de-ID-E.doc OBID i-scan 3.2 Wiring Mounting Instruction RWF1 Fig. 2 and Table 2 show the pin assignments for Terminal X9. The pin connector is designed for cable connection using a 6 pin multipoint socket connector typ Molex MicroFit. H S I L G N E Fig. 2 Terminal Molex MicroFit, 6pin. X9 Pin-No. Function Description 1 2 3 4 5 6 GND TxD
RxD
VCC*
Ground RS232 Transmit Data N.C. RS232 Receive Data N.C. 24VDC Power Supply
Use regulated DC power supplies only!
Table 2: Pin Assignment of the multipoint connector X9 Note:
A wrong polarity of the DC voltage will destroy the reader FEIG ELECTRONIC GmbH Page 21 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan 3.2.1 Supply voltage Mounting Instruction RWF1 The RWF1 must be supplied only by a regulated power supply. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 10 m. A twisted pair cable is recommended. Note:
A wrong polarity of the DC voltage will destroy the reader Supply voltages outside the specifications may destroy the device. FEIG ELECTRONIC GmbH Page 22 of 31 M90900-4de-ID-E.doc OBID i-scan 3.2.2 RS232-Interface Mounting Instruction RWF1 The length of the cable to the RS232 interface should be kept as short as possible, and should not exceed 10m. The dependence of the baud rate has to be considered. The transmission parameters for the interface can be software-configured. Table 3 shows the standard parameters for the RS232 interface. H S I L G N E Parameter Baudrate Default Setting 38400 bit/s Number of Databits 8 Parity Even Number of Stopbits 1 Table 3 Default parameter of the RS232 FEIG ELECTRONIC GmbH Page 23 of 31 M90900-4de-ID-E.doc OBID i-scan Mounting Instruction RWF1 3.2.3 Connection of the external antennas Up to 8 external antennas can be connected. For the connection of the external antennas 8 antenna connectors (A1...A8) are available. The connector type is MMCX. H S I L G N E Fig. 3 Antenna connectors Note:
The maximum antenna cable length should not increase a maximum length of 150cm
(24inch). Cable length more than one meter can result in a shorter reading distance up to -10%. The input impedance for the antenna must be calibrated to a value of 50
(3 3). A not correct tuned antenna can destroy the reader. The optimum working quality of the antenna should be in a range of QB = 10...20. For measuring the working quality the antenna must be connected with a 50 e.g. a network analyzer or a frequency generator
-source, When connecting an antenna, ensure that it does not exceed the permissible limits pre-
scribed by the national regulations for radio frequency devices. FEIG ELECTRONIC GmbH Page 24 of 31 M90900-4de-ID-E.doc OBID i-scan 3.3 Installation notes Mounting Instruction RWF1 The reader module has been designed for the installation in a device. 3.3.1 Mounting The reader module can be mounted by using 2,5mm (M2,5) screws. H S I L G N E Component side: the maximum head diameter should not increase more than 6mm. Preferred no metallic screws should be used (DIN7985). Alternatively internal hexagon screws can be used (DIN 912). Component underside: conductive materials can have a diameter of 6mm. Non-conductive materials can have a diameter of up to 10mm. The mounting orientation of the reader module is arbitrary. The component side on the top is the preferred orientation. Check the planed mounting place first for suitability. 3.3.2 Influence Be aware of the following possible environmental factors when installing the module into another device :
Effects from nearby metal objects Detuning of the integrated antenna Impaired propagation of the antennas magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 3.3.3 EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an reader module into another device, be sure therefore that a clean, noise-free power supply is used. FEIG ELECTRONIC GmbH Page 25 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 3.3.4 EMC effects from magnetic fields Since in this type of RFID-Technology the communication between the reader and transponder takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the an-
tenna can have a negative impact on its function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. FEIG ELECTRONIC GmbH Page 26 of 31 M90900-4de-ID-E.doc OBID i-scan 4 Technical Data Mechanical Data Housing Mounting Instruction RWF1
(sealed-in electronics) H S I L G N E Dimensions (W x H x D) 90 x 62 x 18,6 mm (3.54 x 2.44 x 0.73 inch) Weight Connector 77 g 6 Pin Molex MicroFit 6 plug Electrical Data Supply voltage 24V DC 10%
Current draw max. 100mA Power consumption max. 2 Watt Operating frequency 13,56 MHz Transmitting power 200mW 1dB Antenna connection up to 8 external Antennas (50Ohm)
(Connector: MMCX) Max. cable lentgh1,5m. (by cable length from 1m -
1,5m a reduced reading distance of 10% is possible) Interface RS232 (V24) (max. Cable length 10m) Functional Properties Protocol Modes Supported transponders FEIG ISO HOST ISO15693 EEPROM (for parameters) 1kB (10.000 write cycles) FLASH 64 kB (Firmware Update via interface possible) FEIG ELECTRONIC GmbH Page 27 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Ambient Conditions Temperature range
- Operation
- Storage Mounting Instruction RWF1
-20C to +70C
-40C to +85C
(-4F to 158F)
(-40F to 185F) Humidity 5 95% non condensing EN 300 330-1/-2 EN 302 291 FCC 47 CFR Part 15 IC RSS 210 Issue 8 Radio ordinance item 3 article 44-1 EN 300 489-1/-3 EN 61326-1/-2-6 EN 60950 EN 62311 Applicable Norms Radio approval
- Europe
- USA
- Canada
- Japan EMC Safety FEIG ELECTRONIC GmbH Page 28 of 31 M90900-4de-ID-E.doc H S I L G N E Mounting Instruction RWF1 OBID i-scan 5 Radio Approvals 5.1 Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification gem ETSI EN 300 330: Class 2 FEIG ELECTRONIC GmbH Page 29 of 31 M90900-4de-ID-E.doc H S I L G N E OBID i-scan Mounting Instruction RWF1 Product names:
Reader name:
FCC ID:
IC:
RWF1 RWF1 YQF-RWF1 3100D-RWF1 Notice for USA and This device complies with Part 15 of the FCC Rules and with Canada RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada appli-
cables aux appareils radio exempts de licence. L'exploitation est auto-
rise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonc-
tionnement. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Page 30 of 31 M90900-4de-ID-E.doc H S I L G N E Mounting Instruction RWF1 OBID i-scan 6 Annex 6.1 Accessories The following accessories are available for the Reader. Article No. Part No. Description 3482.000.00.00 ID ISC.ANT30/26-Ro HF Antenne Roche External antenna (PCB board) Dimensions: 30mm x 26mm Table 4: Accessories FEIG ELECTRONIC GmbH Page 31 of 31 M90900-4de-ID-E.doc
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2011-09-13 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2011-09-13
|
||||
1 | Applicant's complete, legal business name |
Roche Diagnostics International Ltd
|
||||
1 | FCC Registration Number (FRN) |
0020139267
|
||||
1 | Physical Address |
Forrenstrasse 2
|
||||
1 |
Rotkreuz, N/A 6343
|
|||||
1 |
Switzerland
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
m******@cetecom.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
YQF
|
||||
1 | Equipment Product Code |
RWF1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G**** H****
|
||||
1 | Title |
Department Project Leader
|
||||
1 | Telephone Number |
+41 4******** Extension:
|
||||
1 | Fax Number |
+41 4********
|
||||
1 |
g******@roche.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader System | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CTC advanced GmbH (former CETECOM ICT Services )
|
||||
1 | Name |
G**** S****
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 | 50.0000000000 Hz |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC