Aroco AC-BLE-T110 iBeacon Quick Start Guide Revision: v1.1 Updated: 26 Nov 2020 Specification AC-BLE-T110:
Mechanics Data Size Weight Casing Electrics Data Bluetooth Chip Frequency Memory BLE Version Input/ Output Interface Battery Life Time Approx. 60.3 x 43.3 x 21.1 mm Approx. 25 grams (without Battery) Approx. 34 grams (with Battery) PC/ABS Case Nordic nRF52840 2.4GHz 256kB Ram, 1MB Flash Bluetooth 5 compatible iBeacon compatible BT4.2 Advertise Mode supported Long Range (PHY Coded) Mode supported 1 Digital Input for Magnet Door Switch, Flood Detection 1 Digital Output reserved I2C interface for external device Non-rechargeable Battery CR2477 (3V 1000mAh) Base on different interval and power setting Transmission Range Up to 200m (with Long Range PHY Coded Mode) Environmental Conditions Operating Temperature
-25C to +75C Waterproof Rating IP68 Material Resistance UV resistance Extended Battery Compartment:
Size Weight Casing Battery Approx. 81.8 x 61.3 x 36.6 mm Approx. 54 grams (without Battery) PC/ABS Case 2 x C-Type 1.5 Batteries Appr. 5000mAh Waterproof Rating IP68 Material Resistance UV resistance Instructions for Connect the Beacon 1. Download the Aroco Beacon Configuration Android App (version 1.2) from following QR Code url:
Android version: 5.1 or upper 2. Unscrew the screw and open the cover. Fill in battery CR2477 to Turn On the Beacon.
3. Start the App. Allow Devices Location permission, Enable Bluetooth and Location. 4. Press the Change Mode Button on the Beacon board. Beacon will enter configuring mode Change Mode Button Indicator LED Indicator Blue LED has different Flashing Rate in different Mode iBeacon Mode: Indicator LED Flash 4990ms Off 10ms On Configuring Mode: Indicator LED Flash 1600ms Off 400ms On The Indicator LED will stay On when the Beacon in Configuring Mode and connected the Mobile App Beacon will back to iBeacon Mode for save energy while no any connection over 60 seconds; or press Disconnect Button in Mobile APP, press change mode button after Indicator LED flash. 5. Press Connect button on the Mobile App to scan and connect the Beacon. 6. Select the Beacon and Tap to connect. All current parameter will be read. Beacon Configuration UUID: 16 Bytes UUID data can be changed. Non-hexadecimal content will be blocked.
(Default: aa55bb44cc33dd22ee11+6bytes Beacon MAC address) If new UUID length not 32, the notice will be shown as below and all parameter cannot be updated. Manufacturing Code: 2 Bytes Code data can be changed. Non-hexadecimal content will be blocked. (Default: 0x004C) If new Mfg. Code is empty, the notice will be shown as below and all parameter cannot be updated. Major: Range 0 to 65535 (Default: 0) Minor: Range 0 to 65535 (Default: 0) Battery Level (Batt lvl): Tick box for choose the data advertising of Beacon Battery Level;
Click Button to show the current Battery Level in mV Battery Level reporting will cover the upper 4 bits of Major TX Power (dBm): Combo Box choice include -20, -16, -12, -8, -4, 0, 2, 3, 4, 5, 6, 7, 8 (Default: -
12) 2 x Adv: Tick box for data advertising by Double Advertisement Advertising Interval (ms): Range 50-3600000. (Default: 650) If new Adv. Interval is empty or less than 50, the notice will be shown as below and all parameter cannot be updated. Advertising Type: Tick Box to choice Normal Type (BT4.2) or/ and Long Range Type (BT5)
(Default: Normal (BT4.2) Type only) Tick both box for choose the both type PIN: 4 digits PIN (Alphabet or number) for Login when every connection create (Default: 1234) If new PIN length not 4, the notice will be shown as below and all parameter cannot be updated to Device after press Send Config button.
* Configuration APP will send all the above parameter to change the Beacon config by press Send Config Button. No any parameter will be updated individually if any input error notice appear.
** Bottom Text Box will show the current status include:
Device: Not Connected No Device Connected Device: ARO_xxxxxx config read Connected and Read Device Config Device: ARO_xxxxxx BattLvl read Read current Battery Level Device: ARO_xxxxxx PIN updated Updated PIN No. Device: ARO_xxxxxx config updated Updated Device Config
*** Press and Hold the Change Mode Button 5 seconds under iBeacon Mode to restore all above config to default. FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.