AUTOMATE | E ARC TUBULAR AC MOTOR 433 MHZ BI-DIRECTIONAL ELECTRONIC LIMIT QUIET OPERATION FAVORITE POSITION LEVEL CONTROL AUTOMATE | E tubular AC motors combine the simple, intuitive features of ARC Automate Radio Communication with the higher lifting capacity of an AC motor for larger shade applications. Leveling Control allows for precise positioning of individual or multiple shades ensuring perfect alignment every time whilst bi-directional communication ensures you can always keep track of your shades position when integrated into smart home applications. A/C Line Voltage (available for both 100V-120V & 220V-240V applications) 433 MHz Bi-Directional RF Communication FEATURES:
Electronic Limits Leveling Control Favorite Position Roller & Tilt Modes 6 1 0 2 C E D 0
. 1 V C A _ e t a m o t u A _ F R C A T M
. R T S N I Slim Head design Reduces Light Gaps Quiet Operation NOTES 2 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA CONTENTS 1 ASSEMBLY 2 WIRING 2.1 Power options 3 P1 BUTTON FUNCTIONS 3.1 Motor state test 3.2 Motor configuartion options 4 INTIAL SET-UP 4.1 Pair motor with controller 4.2 Check motor direction 4.3 Set limits 5 ADJUSTING LIMITS 5.1 Adjust upper limit 5.2 Adjust lower limit 6.1 Using motor P1 button 6.2 Using a pre-existing controller 7 FAVORITE POSITIONING 7.1 Set a favorite position 7.2 Send shade to favorite position 7.3 Delete favorite position 8 TILT & ROLLER MODE 8.1 Enter tilt mode 8.2 Enter roller mode (Default) 9 SLEEP MODE 10 TROUBLESHOOTING 6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 5 6 6 7 7 7 8 8 8 9 10 10 10 11 11 11 12 12 12 12 13 13 13 13 14 3 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA SAFTEY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturers liability and warranty. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Ensure correct crown and drive adaptors are used for the intended system. Do not cut the antenna. For use within tubular blinds. Do not allow children to play with this device. Keep antenna straight and clear from metal objects Do not expose to moisture or extreme temperatures. CAUTION Motor is to be installed in horizontal application only. If cable or power connector is damaged do not use. Use only Rollease Acmeda hardware. Do not drill into motor body. The routing of cable through walls shall be protected by isolating bushes or grommets. Ensure power cable and aerial is clear and protected from moving parts. Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. Ensure torque and operating time is compatible with end application. Do not expose the motor to water or install in humid or damp environments. Important safety instructions to be read prior to operation. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. should not be allowed to use this product. Keep remote controls away from children. Keep motor away from acid and alkali. Do not force the motor drive. Keep clear when in operation. 4 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 5005833 Please refer to Rollease Acmeda System Assembly Manual for full assembly instructions relevant to the hardware system being used. 1 ASSEMBLY Step 1. Cut roller tube to required length. Step 2. Ensure roller tube is clean and free from burrs. Step 3. Fit required crown, drive and bracket adapters. Tube must be close fitting with chosen crown and drive adapters. Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive, and bracket adapter kits. Crown Retaining Clip Drive Step 4. Slide Motor into tube. Insert by aligning keyway in crown and drive wheel to the tube. Step 5. Mount motorized tube onto brackets. Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive, and bracket adapter kits. Motor Head Adapter Bracket 5 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 2 WIRING 2.1 Power options Cut off the mains power supply Connect the motor according to the information in the table below. AC 1 2 3 220 - 240V/50Hz according to product nameplate Power Off Power off 1 2 3 Blue = Neutral Brown = Direction 3 x 1,5 mm2 Green/Yellow = Earth 3 x 0.75 mm2 30.75mm 240V/50Hz 1 2 3 1 2 3 Range Neutral Live Earth 220-240V 100-120V Blue White Brown Yellow / Green Black Green Ensure cable is kept clear of fabric. Ensure antenna is kept straight and away from metal objects. 6 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 3 P1 BUTTON FUNCTIONS 3.1 Motor state test This table describes the function of a short P1 button press/release (<2 seconds) depending on current motor configuration. P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described If limit is NOT None No Action None No Action set If limits are set Short Press Operational control of motor, run to limit. Stop if running Motor runs None None Operational control of motor after pairing and limit setting is completed first time Motor is restored from Sleep Mode and RF control is active If motor is in Sleep Mode &
Wake and control limits are set Motor wakes and runs in a direction The P1 Button is utilized to administer motor configuration as described below and beginning in Section Hold P1 P1 Activate Pairing Mode Approx. Motor Response Sleep Mode Approx. Motor Response Reverse Direction Motor Response Approx. NOTE Reverse motor direction from P1 button only when motor does not have any limits. Reset To Factory Settings Approx. Motor Response 7 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 4 INTIAL SET-UP 4.1 Pair motor with controller Select channel on controller. head. Hold P1 button on motor Hold STOP on controller. IMPORTANT Motor Response Motor Response Consult user manual for your controller for information on selecting channel. Motor is now in step mode and ready for setting limits 4.2 Check motor direction or DOWN on controller. To check travel direction of shade, press UP To reverse shade direction, hold both UP and DOWN. Until the motor responds. Quick Press = Step Long Press = Continuous Travel Motor Response IMPORANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. IMPORTANT Reversing motor direction using this method is only possible during initial set-up. 8 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 4.3 Set limits To save upper limit, hold UP and STOP. Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save lower limit, hold DOWN and STOP. IMPORTANT Motor Response Cycle shade up and down prior to setting limits to settle fabric 5 SECS IMPORTANT After setting limits, motor will automatically exit from initial set-up mode. Initial set-up is now complete 9 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 5 ADJUSTING LIMITS 5.1 Adjust upper limit Hold UP and STOP on controller. Move shade to the desired highest position by pressing the UP button. To save upper limit, hold UP and STOP. Motor Response 5 SECS 5.2 Adjust lower limit Hold DOWN and STOP on controller. Motor Response 5 SECS Move shade to the desired lowest position by pressing the DOWN button. To save lower limit, hold DOWN and STOP. Motor Response 5 SECS Motor Response 5 SECS 10 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 6.1 Using motor P1 button Hold P1 button on motor head. Hold STOP on controller to add or remove. Motor Response Motor Response 6.2 Using a pre-existing controller Press P2 on existing controller. Press P2 on existing controller. Press P2 on new controller. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor. 7 FAVORITE POSITIONING 7.1 Set a favorite position Move shade to the desired position by pressing the UP or DOWN button on the controller. Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response 7.2 Send shade to favorite position Hold STOP on controller. 7.3 Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response 12 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 8 TILT & ROLLER MODE 8.1 Enter tilt mode For slat adjustment on venetians. Hold UP and DOWN on controller. Press STOP. Motor Response Motor Response 8.2 Enter roller mode (Default) Hold UP and DOWN on controller. Press STOP. Motor Response Motor Response 5 SECS 5 SECS 9 SLEEP MODE Enter Sleep Mode Exit Sleep Mode Sleep mode is utilized to prevent a motor from moving during shipping of a fabricated shade Exit sleep mode once the shade is installed Hold P1 button on the motor head Press and release P1 button on the motor head Motor Response Motor Response 13 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA 10 TROUBLESHOOTING Problem Cause Remedy Batteries in wand are depleted Replace 8 x AA alkaline batteries. A/C power supply not plugged in. Check motor to power cable connection and AC plug. Transmitter battery is discharged Replace battery Motor is not responding Radio interference/shielding Receiver distance is too far from transmitter Move transmitter to a closer position Power failure Incorrect wiring Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal Check power supply to motor is connected and active Check that wiring is connected correctly (refer to motor installation instructions) Always reserve an individual channel for programming functions SYSTEM BEST PRACTICE - Provide an extra 15 channel controller in your multi motor projects, that provides individual control for each motor for programming purposes Place all other motors into sleep mode (ref to P1 button function overview - Section 3) Cannot program a single Motor
(multiple motors respond) Multiple motors are paired to the same channel. 14 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA NOTES This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. 15 | Automate Programming Instructions | AC Tubular Motors ROLLEASE ACMEDA Queensland Branch Unit 2/62 Borthwick Avenue, Murarrie QLD 4172 ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 | F +61 3 9355 0110 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan
(Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 16 | Automate Programming Instructions | AC Tubular Motors