MOTOR PROG RAMMING I NSTRUCTIONS Li-ion 0.5 ARC Motor Live Feedback Fav Position SOFT STOP ELECTRONIC LIMIT SELECTABLE SPEED 433 MHZ BI-DIRECTIONAL FAVORITE POSITION BATTERY CHECK USB CHARGE
(Only for Li-ion Motor) SOLAR OPTION LEVEL CONTROL BATTERY POWERED AUTOMATE 5V ZERO & WIREFREE V1.0_PRGM_JULY_2022 SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturers liability and warranty. WARNING: Important safety instructions to be read before installation and use. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. WARNING: Incorrect installation or use can lead to serious injury and will void manufacturers liability and warranty. For 1.1Nm motor series (MT01-1325-069002, MT01-1225-069002 and similar): Rated torque of 1.1Nm, rated operating time of 12 minutes and minimum tube diameter of 25mm. For 2.0Nm motor series (MT01-1328-069001, MT01-1228-069002 and similar): Rated torque of 2.0Nm, rated operating time of 12 minutes and minimum tube diameter of 28mm. Fixed controls have to be clearly visible after installation. The appliance is intended to be installed at a height of at least 2.5m above the floor or any other accessible level surface. Before installing the appliance, remove any unnecessary cords or components and disable any equipment not needed for powered operation. Read and follow all installation and safety instructions. This manual is also available on the website. Do not expose to water, moisture, humid and damp environments or extreme temperatures. Use or modification outside the scope of this instruction manual will void warranty. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children should not play with the appliance. Cleaning and user maintenance should not be performed by children without supervision. Do not allow children to play with fixed controls. Keep appliance and remote controls away from children. Assembly, installation and programming must be performed by a suitably qualified installer. For use with motorized shading devices. Frequently inspect the installation for improper operation, signs of wear, imbalance or damage to cables or springs. Do not use if repair or adjustment is necessary. The appliance must be disconnected from its power source during cleaning, maintenance or when replacing parts. Maintenance and parts replacement should be performed by a suitably qualified installer/technician. The A-weighted emission sound pressure level of the appliance is less than or equal to 70dB(A). The appliance is for indoor use only. Disconnect the appliance from power or switch off automatic controls when maintenance, such as window cleaning, is being carried out in the vicinity. The appliance must be supplied only the safe, extra-low voltage corresponding to the marking on the appliance. Keep clear of the appliance when in operation. There are no user serviceable parts or batteries inside the appliance. Remote batteries should be replaced with the correctly specified type only. The mass and dimensions of the driven part must be compatible with the rated torque and rated operating time of the appliance. The driven part must be compatible with the rated torque and operating time of the appliance as follows:
For 0.5Nm motor series (MT01-1320-069001 and similar):
Rated torque of 0.5Nm, rated operating time of 12 minutes and minimum tube diameter of 20mm. 2 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA COMPLIANCE STATEMENT This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installes doivent tre situes de facon ce que la population ne puisse y tre expose une distance de moin de 20 cm. Installer les antennes de facon ce que le personnel ne puisse approcher 20 cm ou moins de la position centrale de l antenne. La FCC des ltats-unis stipule que cet appareil doit tre en tout temps loign dau moins 20 cm des personnes pendant son functionnement. ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 3 12 BATTERY CHECK FUNCTION 12.1 Send Shade to battery charge level 13 CHARGING LED 13.1 Turn Charging LED ON/OFF 14 SLEEP MODE 15 TROUBLE SHOOTING 16 NOTES 16 16 16 16 17 18 20 CONTENTS ASSEMBLY RETROFIT INSTALLATION CHARGING/POWER SUPPLY P1 BUTTON FUNCTIONS 1 2 3 4 4.1 Motor state test 4.2 Motor configuration options 5 INITIAL SET UP 5.1 Pair motor with controller 5.2 Check motor direction 5.3 Set Limits 6 ADJUSTING LIMITS 6.1 Adjust upper limit 6.2 Adjust lower limit 7 CONTROLLERS AND CHANNELS 5 6 6 7 7 7 8 8 8 9 10 10 10 11 7.1 Using P2 Button on existing controller to add a new controller or channel 11 7.2 Using a pre-existing controller to add or delete a controller or channel 11 8 FAVORITE POSITIONING 8.1 Set a favorite position 8.2 Send shade to favorite position 8.3 Delete favorite position 9 TILT & ROLLER MODE 9.1 Toggle motor to Tilt Mode 9.2 Toggle Motor to Roller Mode 10 ADJUSTING SPEED 10.1 Increase Motor Speed 10.2 Decrease Motor Speed 11 SOFT STOP CONFIGURATION 11.1 Turn Soft Stop OFF 11.2 Turn Soft Stop ON 12 12 12 12 13 13 13 14 14 14 15 15 15 4 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 1 ASSEMBLY ZERO HEAD ADAPTER GENERIC CROWN, DRIVE & TUBE ASSEMBLY ZERO HEAD ANTENNA WRAP ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 5 2 RETROFIT INSTALLATION
(1.1Nm & 2.0Nm MOTOR ONLY) 3 CHARGING/POWER SUPPLY
(LI-ION 1.1Nm & 2.0Nm ONLY)
(LI-ION 3.0Nm & 10.0Nm ONLY)
(DC 1.1Nm & 2.0Nm ONLY) 6 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA Requries a continuous 12V DC Power Source. 4 P1 BUTTON FUNCTIONS 4.1 Motor state test This table describes the function of a short P1 Button press/release (<2 seconds) depending on current motor configuration. P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described If limit is NOT set None No Action None No Action If limits are set Short Press If motor is in Sleep Mode &
limits are set Operational control of motor, run to limit. Stop if running Wake and control 4.2 Motor configuration options Motor Runs None Operational control of motor after pairing and limit setting is completed first time Motor wakes and runs in a direction None Motor is restored from Sleep Mode and RF control is active The P1 Button is utilized to administer motor configurations as described below. Hold P1 button on motor head. Activate Pairing Mode Approx. Sleep Mode Approx. Approx. Reverse Direction Approx. Approx. Approx. 10 Reset To Factory Settings Approx. Approx. Approx. 10 Approx. P1 button on motor head. ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 7 5 INITIAL SET UP 5.1 Pair motor with controller Select channel on controller. Hold P1 button on motor head. Hold STOP on controller. IMPORTANT Consult user manual for your controller for information on selecting channel. Motor Response Motor Response Approx. Motor is now in step mode and ready for setting limits 5.2 Check motor direction To check travel direction of shade, press UP or DOWN on controller. To reverse shade direction, hold both UP and DOWN. Until the motor responds. OR Quick Press = Step Long Press = Continuous Travel Motor Response Approx. IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. IMPORTANT Reversing motor direction using this method is only possible during initial set-up 8 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 5.3 Set Limits IMPORTANT Cycle shade up and down prior to setting limits to settle fabric Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save upper limit, hold UP and STOP. OR Motor Response Approx. 5 SEC S Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save lower limit, hold DOWN and STOP. OR Motor Response Approx. 5 SEC S IMPORTANT After setting limits, motor will automatically exit from initial set-up mode. ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 9 6 ADJUSTING LIMITS 6.1 Adjust upper limit Hold UP and STOP on controller. Move shade to the desired highest position by pressing the UP or DOWN button. To save upper limit, hold UP and STOP. OR Motor Response Approx. 5 SEC S Move shade to the desired lowest position by pressing the UP or DOWN button. To save lower limit, hold DOWN and STOP. OR Motor Response Approx. 5 SEC S Motor Response Approx. 5 SEC S 6.2 Adjust lower limit Hold DOWN and STOP on controller. Motor Response Approx. 5 SEC S IMPORTANT The bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised. 10 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 7 CONTROLLERS AND CHANNELS 7.1 Using P2 Button on existing controller to add a new controller or channel A = Existing controller or channel (to keep) B = Controller or channel to add or remove Press P2 on controller A. Press P2 on controller A. Press STOP on an new controller to add it. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor 7.2 Using a pre-existing controller to add or delete a controller or channel A = Existing controller or channel (to keep) B = Controller or channel to add or remove Press P2 on controller A. Press P2 on controller A. Press P2 on the controller B to remove it. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 11 8 FAVORITE POSITIONING 8.1 Set a favorite position Move shade to the desired position by pressing the UP or DOWN button on the controller. Press P2 on controller. Press STOP on controller. Press STOP on controller. OR Motor Response Motor Response Motor Response 8.2 Send shade to favorite position Approx. 8.3 Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response 12 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 9 TILT & ROLLER MODE 9.1 Toggle motor to Tilt Mode Default motor mode is Roller after initial Limits have been set, use following steps to change to Roller Mode. Hold UP & DOWN on controller. Press STOP on controller. Motor Response Motor Response Approx. 5 SEC S 9.2 Toggle Motor to Roller Mode If motor is in Tilt Mode, use following steps to change to Roller Mode. Hold UP & DOWN on controller. Press STOP on controller. Motor Response Motor Response Approx. 5 SEC S ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 13 10 ADJUSTING SPEED 10.1 Increase Motor Speed Default motor mode is the slowest speed. Press P2 Press UP Press UP Motor Response Motor Response Motor Response 10.2 Decrease Motor Speed Press P2 Press DOWN Press DOWN Motor Response Motor Response Motor Response 14 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 11 SOFT STOP CONFIGURATION 11.1 Turn Soft Stop OFF Motor must be in slowest speed to turn Soft Stop OFF. Press P2 Press DOWN Press DOWN Motor Response Motor Response Motor Response 11.2 Turn Soft Stop ON Motor must be in fastest speed to turn Soft Stop ON. Press P2 Press UP Press UP Motor Response Motor Response Motor Response ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 15 12 BATTERY CHECK FUNCTION 12.1 Send Shade to battery charge level Shade must be at Upper Limit. Hold UP Upper Limit Percentage of Battery Charge Remaining Lower Limit Percentage Depleted Motor Response Approx. SEC5 Shade must be at Upper Limit Hold UP for Approx. 5s Shade moves to percentage of battery charge remaining NOTE: This feature is can only be used with a DC motor when it is using a Barrery Pack as its power source. 13 CHARGING LED
(ONLY FOR LI-ION MOTORS) 13.1 Turn Charging LED ON/OFF Motor must be at Lower Limit. Hold DOWN to toggle off Hold DOWN to toggle on CHARGING LED STATUS SOLID GREEN Motor is fully charged Motor Response Motor Response Approx. 5 SEC S Red LED flashes x3 Approx. 5 SEC S Red LED flashes x3 BLINKING GREEN Motor is charging. Battery is greater than 50%. BLINKING GREEN & RED Motor is charging. Battery is lower than 50%. 16 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 14 SLEEP MODE 9 SLEEP MODE If multiple motors are grouped on a single channel, Sleep Mode may be used to put all but 1 motor to sleep, allowing programming of just the one motor that remains Awake. See page 6 for detailed P1 functions. Enter Sleep Mode Sleep mode is utilized to prevent a motor from incorrect configuration during other motor setup. Hold P1 button on the motor head Exit Sleep Mode: Method 1 Exit Sleep Mode: Method 2 Exit sleep mode once the shade is ready. Remove power and then re-power the motor. Press and release P1 button on the motor head Motor Response Motor Response Approx. ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 17 G 15 TROUBLE SHOOTING automateshades.com Problem Cause Remedy Motor is not responding Battery in motor is depleted or Power Supply is not working Recharge with a compatible charger Insufficient charging from solar PV panel Check connection and orientation of PV panel Transmitter battery is discharged Replace battery Battery is inserted incorrectly into transmitter Radio interference/shielding Check battery polarity Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal Receiver distance is too far from transmitter Move transmitter to a closer position Charging failure Motor beeps x10 when in use Battery voltage is low Cannot program a single motor
(multiple motors respond) Multiple motors are paired to the same channel Check power supply to motor is connected and active Recharge with a compatible charger Always reserve an individual channel for programming functions. Use Sleep Mode to program individual motors. ROLLEASE ACMEDA | USA Level 7 / 750 East Main Street Stamford, CT 06902, USA ROLLEASE ACMEDA | AUSTRALIA ROLLEASE ACMEDA | EUROPE 110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +1 800 552 5100 | F +1 203 964 0513 T +61 3 9355 0100 | F +61 3 9355 0110 T +39 02 8982 7317 | F +39 02 8982 7317 18 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 16 NOTES ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 19 16 NOTES 20 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA